Literatura científica selecionada sobre o tema "Monochromatization"
Crie uma referência precisa em APA, MLA, Chicago, Harvard, e outros estilos
Consulte a lista de atuais artigos, livros, teses, anais de congressos e outras fontes científicas relevantes para o tema "Monochromatization".
Ao lado de cada fonte na lista de referências, há um botão "Adicionar à bibliografia". Clique e geraremos automaticamente a citação bibliográfica do trabalho escolhido no estilo de citação de que você precisa: APA, MLA, Harvard, Chicago, Vancouver, etc.
Você também pode baixar o texto completo da publicação científica em formato .pdf e ler o resumo do trabalho online se estiver presente nos metadados.
Artigos de revistas sobre o assunto "Monochromatization"
ZHOU YUN-SONG, RAN JING-HUI, CHEN JIN-CHANG e YI XIANG-DONG. "A NEW METHOD OF NEUTRON MONOCHROMATIZATION". Acta Physica Sinica 46, n.º 5 (1997): 929. http://dx.doi.org/10.7498/aps.46.929.
Texto completo da fonteBurdilov, Alexander, Gleb Dovzhenko, Ivan Bataev e Anatoly Bataev. "Methods of synchrotron radiation monochromatization (research review)". Metal Working and Material Science 26, n.º 3 (13 de setembro de 2024): 208–33. http://dx.doi.org/10.17212/1994-6309-2024-26.3-208-233.
Texto completo da fonteJark, Werner. "Concepts for flexible and efficient monochromatization of X-rays by refraction to a relative bandwidth of the order of 0.5%". Journal of Synchrotron Radiation 20, n.º 1 (10 de novembro de 2012): 190–93. http://dx.doi.org/10.1107/s0909049512041556.
Texto completo da fonteSergueev, Ilya, Konstantin Glazyrin, Markus G. Herrmann, Pavel Alexeev, Hans-Christian Wille, Olaf Leupold, Andrew F. May et al. "High-pressure nuclear inelastic scattering with backscattering monochromatization". Journal of Synchrotron Radiation 26, n.º 5 (23 de agosto de 2019): 1592–99. http://dx.doi.org/10.1107/s1600577519008853.
Texto completo da fonteSurdu-Bob, C. C., e G. Musa. "The kinetics of monochromatization of plasma light emission". Journal of Physics D: Applied Physics 41, n.º 17 (7 de agosto de 2008): 172004. http://dx.doi.org/10.1088/0022-3727/41/17/172004.
Texto completo da fonteSchief, Hansjörg, Vittorio Marsico, Klaus Kuhnke e Klaus Kern. "Monochromatization of atomic waves by nanoscopic echelette gratings". Surface Science 364, n.º 3 (setembro de 1996): L631—L637. http://dx.doi.org/10.1016/0039-6028(96)00794-7.
Texto completo da fonteZhang, Hongxia, Juanjuan Liu, Yufeng Zhang, Jinchen Wang, Daye Xu, Peng Cheng, Hongliang Wang e Wei Bao. "Highly aligned pyrolytic graphite blades for neutron monochromatization". Journal of Instrumentation 19, n.º 06 (1 de junho de 2024): P06036. http://dx.doi.org/10.1088/1748-0221/19/06/p06036.
Texto completo da fonteToellner, T. S., A. Alatas e A. H. Said. "Six-reflection meV-monochromator for synchrotron radiation". Journal of Synchrotron Radiation 18, n.º 4 (26 de maio de 2011): 605–11. http://dx.doi.org/10.1107/s0909049511017535.
Texto completo da fonteCotton, J. P., e J. Teixeira. "Time of flight as a monochromatization technique for sans". Physica B+C 136, n.º 1-3 (janeiro de 1986): 103–5. http://dx.doi.org/10.1016/s0378-4363(86)80031-6.
Texto completo da fonteKozhevnikov, S. V. "Neutron monochromatization using spin-flip and spatial beam splitting". Physica B: Condensed Matter 283, n.º 4 (junho de 2000): 305–7. http://dx.doi.org/10.1016/s0921-4526(00)00320-3.
Texto completo da fonteTeses / dissertações sobre o assunto "Monochromatization"
VIEIRA, MARCO ROGERIO. "DEVELOPING A VERSATILE MONOCHROMATIZATION SYSTEM FOR X-RAYS". PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO, 2009. http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=15703@1.
Texto completo da fonteFUNDAÇÃO DE APOIO À PESQUISA DO ESTADO DO RIO DE JANEIRO
A investigação da dinâmica da interação de raios-X de alta energia e moléculas de interesse biológico impõe que a energia dos raios-X seja bem definida, de modo que se possa estabelecer a dependência entre os padrões de ionização e fragmentação molecular com a energia do feixe incidente. Com este objetivo, um sistema versátil foi projetado, construído e caracterizado para ser utilizado como monocromador do feixe de amplo espectro produzido por um tubo de raios-X modelo ISOVOLT 160 M2. O sistema de monocromatização consiste de um par de cristais montados sobre duas mesas transladoras fixadas a um goniômetro de alta precisão, fabricados pela Newport Corporation. Esta configuração permite movimentos de translação independentes para os dois cristais, associados a um movimento de rotação do sistema como um todo com respeito à direção de incidência do feixe de raios-X. Estes movimentos, juntamente com uma escolha conveniente do par de cristais para uma dada faixa de energia - o que depende do material e da orientação dos cristais -, permitirão a cobertura de uma região muito extensa de energias de raios-X, de alguns até cerca de 100 kV. Quando este sistema se encontrar totalmente operacional, será possível realizar uma grande variedade de experiências nos campos da Física de Colisões e das Radiações, tais como, fragmentação molecular induzida por raios- X, fluorescência e difração seletivas em cristais, avaliação em tempo real de danos induzidos por raios-X em tecidos biológicos, testes não destrutivos em materiais, dentre muitas outras aplicações.
The investigation of the dynamics of the interaction of high-energy X-rays and molecules of biological interest requires the energy of the X-rays to be well defined, so that one can establish the dependence of the molecular ionization and fragmentation patterns as functions of the incident beam energy. For this purpose, a versatile system for the monochromatization of the broadband beams produced by an ISOVOLT 160M2 X-ray tube has been designed, constructed and characterized. The monochromator consists of a pair of crystals mounted on two translator tables fixed on a high-precision goniometer, all manufactured by Newport Corp. This configuration allows independent translational motions for the two crystals, associated to a rotational motion of the whole system in respect to the direction of the incident X-ray beam. These motions, together with a convenient choice of the pair of crystals for a given energy range - which depends on the material and orientation of the crystals -, will allow us to cover a wide range of X-rays energies, roughly from few to around 100 keV. However, it has not yet been possible to distinguish energy-defined X-ray peaks with the complete two-crystal system. Some of the possible causes may be related to the large angular dispersion of the incident beam and to the need of more accurate adjustments of the parallelism between both crystals. When this system is fully operational, it will be possible to perform a large variety of experiments in the fields of collision and radiation physics, such as, molecular fragmentation by Xrays, selective fluorescence and diffraction in crystals, real-time evaluation of Xray- induced damage in biological tissues, non-destructive testing of materials, among many other aplications.
Zhang, Zhandong. "Interaction region optics design of a monochromatization scheme for direct s-channel Higgs production at FCC-ee". Electronic Thesis or Diss., université Paris-Saclay, 2024. http://www.theses.fr/2024UPASP139.
Texto completo da fonteThe FCC-ee offers the potential to measure the electron Yukawa coupling via direct s-channel Higgs production at a centre-of-mass (CM) energy of about 125 GeV. This measurement is significantly facilitated if the CM energy spread of electron-positron collisions can be reduced to a level comparable to the Standard Model Higgs boson's natural width of 4.1 MeV without substantial loss in luminosity. Achieving this reduction in collision-energy spread is possible through the “monochromatization” concept. The basic idea consists of creating opposite correlations between spatial position and energy deviation within the colliding beams, which can be accomplished in beam-optics terms by introducing a nonzero dispersion function with opposite signs for the two beams at the interaction point. Since the first proposal in 2016, the monochromatization implementation at the FCC-ee has been continuously improved, starting from preliminary parametric studies. In this thesis, a detailed study of the interaction region optics design has been conducted for this newly proposed collision mode, exploring different potential configurations and their implementation in the FCC-ee global lattice, along with beam dynamics simulations and performance evaluations including the “beamstrahlung” impact
Capítulos de livros sobre o assunto "Monochromatization"
"monochromatization, n." In Oxford English Dictionary. 3a ed. Oxford University Press, 2023. http://dx.doi.org/10.1093/oed/6335813211.
Texto completo da fonteTrabalhos de conferências sobre o assunto "Monochromatization"
Zeni, Gabriele, Fabio Frassetto, Antonio Vanzo, Stefano Bonora e Luca Poletto. "Bendable grating for monochromatization in the extreme-ultraviolet". In X-Ray Free-Electron Lasers: Advances in Source Development and Instrumentation VI, editado por Thomas Tschentscher, Luc Patthey, Marco Zangrando e Kai Tiedtke. SPIE, 2023. http://dx.doi.org/10.1117/12.2665625.
Texto completo da fonteAlp, E. E., E. Witthoff, T. Mooney, H. Homma e M. Kentjana. "Layered Optics for Nuclear Monochromatization of Synchrotron Radiation". In Physics of X-Ray Multilayer Structures. Washington, D.C.: Optica Publishing Group, 1992. http://dx.doi.org/10.1364/pxrayms.1992.mc12.
Texto completo da fonteIbraimov, Nariman S. "Filtration and monochromatization of synchrotron radiation based on capillary optics". In Optical Science, Engineering and Instrumentation '97, editado por Richard B. Hoover e F. P. Doty. SPIE, 1997. http://dx.doi.org/10.1117/12.277679.
Texto completo da fonteHort, O., L. Jurkovičová, J. Vábek, M. Albrecht, M. Staněk, O. Finke, L. Ben Ltaief et al. "Advances in HHG for User Operations: Novel Techniques for Monochromatization". In Compact EUV & X-ray Light Sources. Washington, D.C.: Optica Publishing Group, 2024. http://dx.doi.org/10.1364/euvxray.2024.eth3a.2.
Texto completo da fonteAdischev, Y. N., K. V. Afanasiev, A. V. Vukolov e Alexander P. Potylitsyn. "Monochromatization of high-current nanosecond pulse source of x-ray bremsstrahlung". In SPIE Proceedings, editado por Sultan B. Dabagov. SPIE, 2007. http://dx.doi.org/10.1117/12.741842.
Texto completo da fontevan der Meer, R., B. Krishnan, I. V. Kozhevnikov, M. J. De Boer, B. Vratzov, H. M. J. Bastiaens, J. Huskens et al. "Improved resolution for soft-x-ray monochromatization using lamellar multilayer gratings". In SPIE Optical Engineering + Applications, editado por Christian Morawe, Ali M. Khounsary e Shunji Goto. SPIE, 2011. http://dx.doi.org/10.1117/12.892687.
Texto completo da fonteWagner, Volker, e Pavel Mikula. "Use of focusing by bent perfect Si crystals for short-wavelength neutron monochromatization". In San Diego '92, editado por Charles F. Majkrzak e James L. Wood. SPIE, 1992. http://dx.doi.org/10.1117/12.130653.
Texto completo da fonteSchaefers, F., M. Grioni, J. Wood, H. Van Brug, E. J. Puik, M. Dapor e F. Marchetti. "Application Of W/Si Multilayers For Monochromatization Of Soft X-Ray Synchrotron Radiation". In 32nd Annual Technical Symposium, editado por Charles F. Majkrzak. SPIE, 1989. http://dx.doi.org/10.1117/12.948760.
Texto completo da fonteSchaefers, F., M. Grioni, J. Wood, H. van Brug, E. J. Puik., M. Dapor e F. Marchetti. "Application Of W/Si Multilayers For Monochromatization Of Soft X-Ray Synchrotron Radiation". In 32nd Annual Technical Symposium, editado por Finn E. Christensen. SPIE, 1988. http://dx.doi.org/10.1117/12.948766.
Texto completo da fonteMarshall, Gerald F. "Monochromatization By Multilayered Optics On A Cylindrical Reflector And On An Ellipsoidal Focusing Ring". In 30th Annual Technical Symposium, editado por D. Keith Bowen e Larry V. Knight. SPIE, 1986. http://dx.doi.org/10.1117/12.936621.
Texto completo da fonteRelatórios de organizações sobre o assunto "Monochromatization"
Seryi, A. Monochromatization Option for NLC Collisions(LCC-0134). Office of Scientific and Technical Information (OSTI), março de 2004. http://dx.doi.org/10.2172/826823.
Texto completo da fonte