Tesis sobre el tema "Centrali a vapore"
Crea una cita precisa en los estilos APA, MLA, Chicago, Harvard y otros
Consulte los 20 mejores tesis para su investigación sobre el tema "Centrali a vapore".
Junto a cada fuente en la lista de referencias hay un botón "Agregar a la bibliografía". Pulsa este botón, y generaremos automáticamente la referencia bibliográfica para la obra elegida en el estilo de cita que necesites: APA, MLA, Harvard, Vancouver, Chicago, etc.
También puede descargar el texto completo de la publicación académica en formato pdf y leer en línea su resumen siempre que esté disponible en los metadatos.
Explore tesis sobre una amplia variedad de disciplinas y organice su bibliografía correctamente.
Oliveira, Junior Valter Barbosa de. "Modelagem de central termelétrica a vapor para simulação dinâmica". Universidade Federal do Espírito Santo, 2009. http://repositorio.ufes.br/handle/10/6220.
Texto completoCentrais termelétricas a vapor são capazes de utilizar biomassa e fazer o reaproveitamento de resíduos agrícolas, resíduos urbanos ou subprodutos industriais para produzir energia elétrica, condicionadas aos seus projetos. Este trabalho tem como objetivos representar, por meio de modelos matemáticos, os principais componentes que constituem o circuito de vapor de uma planta de geração termelétrica a vapor, com foco em caldeira aquatubular, e apresentar uma avaliação dos diversos modelos encontrados na literatura de referência, visando dar suporte ao desenvolvimento de aplicações de simulação dinâmica. Os modelos apresentados abrangem a conversão da energia térmica em energia mecânica e a conversão da energia mecânica em energia elétrica. O conhecimento das características das respostas dinâmicas dos componentes de uma central termelétrica é importante para a análise de estabilidade e para o projeto do sistema de controle. A partir dos modelos dinâmicos do processo é possível a realização de testes de estratégias de controle que, interagindo com os modelos da planta, possibilitem identificar previamente o comportamento dinâmico esperado. Este trabalho também pode ser utilizado como uma referência básica para o desenvolvimento de um simulador com finalidade de treinamento de operadores, cuja aplicação possibilita que seja feita a integração total do operador aos procedimentos operacionais, antes mesmo da partida da planta, ampliando a sua capacidade de aprendizagem
Steam power plants are able to utilize biomass and make the recovering of agricultural residues, urban residues or industrial by-products to produce electric energy, conditioned to its projects. This work aims to represent by means of mathematic modeling the main components that constitute the main steam circuit of a steam power plant, with focus in drum boiler, and to present an analysis of the several models founded at the reference literature, aiming to give support to the development of dynamic simulation applications. The models embrace the conversion of thermal energy in mechanical energy and the conversion of mechanical energy in electric energy. The knowledge of the dynamic response characteristics of power plant components is important for the analysis of stability and control system design. From the dynamic model of process is possible to perform tests of control strategies that, having interaction with the plant models, allow the previous indentifying of its hoped dynamic behavior. This work may be used also as a basic reference to the development of a simulator for operators training purpose, whose application allows the operator to be fully integrated to the operational procedures, before the plant start up, increasing his learning ability
OLIVEIRA, JUNIOR V. B. "Modelagem de Central Termelétrica à Vapor para Simulação Dinâmica". Universidade Federal do Espírito Santo, 2009. http://repositorio.ufes.br/handle/10/9589.
Texto completoCentrais termelétricas a vapor são capazes de utilizar biomassa e fazer o reaproveitamento de resíduos agrícolas, resíduos urbanos ou subprodutos industriais para produzir energia elétrica, condicionadas aos seus projetos. Este trabalho tem como objetivos representar, por meio de modelos matemáticos, os principais componentes que constituem o circuito de vapor de uma planta de geração termelétrica a vapor, com foco em caldeira aquatubular, e apresentar uma avaliação dos diversos modelos encontrados na literatura de referência, visando dar suporte ao desenvolvimento de aplicações de simulação dinâmica. Os modelos apresentados abrangem a conversão da energia térmica em energia mecânica e a conversão da energia mecânica em energia elétrica. O conhecimento das características das respostas dinâmicas dos componentes de uma central termelétrica é importante para a análise de estabilidade e para o projeto do sistema de controle. A partir dos modelos dinâmicos do processo é possível a realização de testes de estratégias de controle que, interagindo com os modelos da planta, possibilitem identificar previamente o comportamento dinâmico esperado. Este trabalho também pode ser utilizado como uma referência básica para o desenvolvimento de um simulador com finalidade de treinamento de operadores, cuja aplicação possibilita que seja feita a integração total do operador aos procedimentos operacionais, antes mesmo da partida da planta, ampliando a sua capacidade de aprendizagem.
Huamán, Esteban Máximo Simón. "Diseño de una turbina de vapor múltiple para una central termoeléctrica". Universidad Nacional de Ingeniería. Programa Cybertesis PERÚ, 1999. http://cybertesis.uni.edu.pe/uni/1999/huaman_em/html/index-frames.html.
Texto completoSilva, Ana Teresa Oliveira Santos. "Análise termodinâmica de uma central de biomassa lenhosa". Master's thesis, Faculdade de Ciências e Tecnologia, 2013. http://hdl.handle.net/10362/9932.
Texto completoPortugal é um país deficitário em fontes de energia não renováveis, mas dispõe de potencialidades significativas no domínio das fontes renováveis, que devidamente aproveitadas podem ajudar a colmatar a deficiência apontada. No caso da biomassa, em particular a de origem florestal, o nosso país tem imensos recursos, pois 38% do território nacional é constituído por florestas. Dispondo deste recurso, o número de centrais termoeléctricas tem vindo a aumentar, embora o rendimento energético seja baixo. Urge assim, um estudo aprofundado que permita conhecer melhor os ciclos termodinâmicos das centrais. A queima da biomassa é difícil, pelo que é importante conhecer certos parâmetros de operação e sua variação ao longo do tempo, de forma a melhorar o rendimento da central. Para tal é necessário modelar o ciclo termodinâmico e fazer uma análise de sensibilidade. É neste âmbito que surge o trabalho de dissertação. Foi feita uma pesquisa e um estudo das técnicas actuais de conversão da biomassa, dos problemas existentes e das características do combustível, em particular do seu teor de humidade e dimensão, que influenciam a sua conversão. Através da realização de um estágio numa Central, foi estudado o seu processo de funcionamento, desde a admissão da biomassa à caldeira até à produção de energia eléctrica, com o objectivo de fazer uma análise termodinâmica ao seu ciclo de vapor. Não tendo acesso à memória descritiva da Central, várias foram as condicionantes e dificuldades com que deparamos, mas foi possível fazer a análise termodinâmica. Para tal, decidiu-se recorrer a uma ferramenta computacional, o Cycle-Tempo, para efectuar a simulação do ciclo termodinâmico, após um levantamento de software disponíveis. Dispor-se de uma ferramenta que permita fazer a modelação de uma central, mesmo já em pleno funcionamento, é extremamente vantajoso pois permite descrever a operação da central, diagnosticar avarias, testar hipóteses e melhorar o ciclo. Recolhidos os parâmetros de funcionamento da Central, foi necessário introduzir pequenas modificações, no decurso do trabalho, no Cycle-Tempo. Após a modelação do ciclo, exploraram-se as vantagens atrás referidas, realizando uma análise de sensibilidade a diversos parâmetros de operação: pressão da caldeira, perda de carga na caldeira mantendo a pressão de saída, temperatura do vapor sobreaquecido, pressão no condensador, temperatura da água de arrefecimento, rendimento isentrópico associado às turbomáquinas, pressão de funcionamento do desgaseificador, potência do gerador. Fez-se ainda uma análise simultânea a vários parâmetros de funcionamento. Dado que o Cycle-Tempo também permite fazer balanços exergéticos, e atendendo a que o estudo do conceito de exergia foi recentemente introduzido na unidade curricular de Termodinâmica Aplicada do DEMI, aproveitou-se para concretizar o balanço exergético a uma central completa. Para concretizar o cálculo foi necessário determinar a exergia do Eucalyptus Globulus. No decorrer do trabalho, identificaram-se limitações no software Cycle-Tempo que motivaram o recurso a uma folha de cálculo, associada à base de propriedades termodinâmicas FluidProp, como processo alternativo à modelação do ciclo. Conseguiu-se modelar o ciclo no Cycle-Tempo depois de identificar e simplificar componentes do ciclo que impossibilitavam uma solução numérica. Da análise de sensibilidade, verificou-se que os parâmetros que mais influenciavam o rendimento do ciclo são a temperatura de sobreaquecimento e a pressão de condensação (influenciada pela temperatura da água de arrefecimento). A pressão do desgaseificador também influencia o rendimento do ciclo, mas a encontrada, 13 bar, é demasiado elevada face à actual de 3 bar, para se considerar um aumento. Tal como em outras áreas do conhecimento, na modelação termodinâmica, a informática também permite, num menor espaço de tempo e com menos esforço, estudar um grande número de configurações, de forma a rentabilizar o ciclo.
JIMENEZ, GARCIA JUAN ANTONIO 789636 y GARCIA JUAN ANTONIO JIMENEZ. "Análisis exergético y termoeconómico de un sistema de generación de energía. Estudio del caso del generador de vapor de 350 MW instalado en la central termoeléctrica “Villa de Reyes”". Tesis de doctorado, Universidad Autonoma del Estado de Mexico, 2015. http://hdl.handle.net/20.500.11799/69009.
Texto completoEn la presente investigación, se desarrolla el análisis exergético y termoeconómico de la central térmica de vapor de Villa de Reyes, que consta de un recalentamiento y dos regeneraciones. Para dicho análisis se determinan las ecuaciones de transferencia de calor y volúmenes de control que describen el comportamiento físico de cada uno de los componentes de la planta. El estudio se divide en varios módulos, integrados de la siguiente manera: a) Modulo del Cálculo térmico del hogar. En este módulo se caracteriza el proceso de combustión en el hogar del generador de vapor, y se determina la temperatura de los productos de la combustión a la salida de la cámara de combustión, dicho valor es fundamental en el diseño de los sobrecalentadores y recalentadores del generador de vapor, ya que con ayuda de la temperatura, se pueden determinar las propiedades termodinámica del lado de los gases, lo que permite realizar los cálculos de la transferencia de calor en los elementos subsecuentes. b) Módulo de la Transferencia de calor. En este módulo se realizan los cálculos de la transferencia de calor en los elementos de intercambio del generador de vapor. (1er, 2do. y 3er sobrecalentadores, 1er y 2do. recalentadores, economizador y precalentador de aire), se determinan las propiedades termodinámicas del vapor a la salida de cada uno de estos elementos. Con la metodología presentada se determina el coeficiente global de transferencia de calor (U) y de las características de flujo, tanto de vapor, como gases de combustión, finalmente, se determina la temperatura a la salida de los gases de combustión y vapor empleando el método de efectividad- NTU. c) Modulo del ciclo Rankine real. En este apartado se realiza el análisis del ciclo térmico de vapor de la central termoeléctrica con recalentamiento y dos regeneraciones, se estudia la influencia que tienen los parámetros de operación de la planta en el rendimiento total del ciclo y se analiza el comportamiento de los elementos de la central termoeléctrica, como son: la turbina de vapor, las extracciones de baja y alta presión de la turbina, condensador, desgasificador y calentador cerrado de agua de alimentación. Para validar el modelo termodinámico, se comparan los resultados obtenidos en los módulos a), b) y c) directamente contra los datos de operación de la central térmica de vapor conocidos (regímenes: 100%,75%,50% y 25%), y una vez validados, se modifican las variables independientes del modelo y se predicen las condiciones de operación a régimen de carga variable, donde se simula la operación de la central termoeléctrica desde el 25% de carga hasta el 100%, realizando la simulación en dependencia del incremento del flujo de combustibles al hogar del generador de vapor y en las presiones de operación establecidas para la central termoeléctrica. d) Modulo del cálculo exergético y termoeconómico, una vez validado el modelo termodinámico y obtenido resultados del análisis del ciclo térmico de vapor, se integran los módulos a, b y c, para realizar el análisis exergético y termoeconómico del ciclo, con lo que se identifican los regímenes de carga más eficientes, se presentan las irreversibilidades de los elementos participantes en el ciclo. los flujos exergéticos y los costos de las irreversibilidades asociados a la operación de la central térmica de vapor a los regímenes de carga seleccionados por sus altas eficiencias, y se presentan los costos asociados a las irreversibilidades de los procesos y los equipos, e) Análisis de sensibilidad, finalmente se realiza un análisis de sensibilidad, donde se estudia la influencia de las principales variables del modelo sobre los resultados obtenidos en la presenten investigación, con la finalidad de observar su efecto sobre la eficiencia térmica y exergética del ciclo, así como sobre el trabajo útil generado. Así también, este análisis permite evaluar las oportunidades de mejora de la central termoeléctrica, ya que las modificaciones en las principales variables del sistema, permiten identificar, los posibles resultados de implementar acciones de mejora en los elementos de la central o en los parámetros de operación. Debido a la naturaleza no lineal de los procesos térmicos que se llevan a cabo en la central térmica de vapor, la simulación de la central térmica de vapor a carga variable, se realiza empleando el método de sustituciones sucesivas, integrando los módulos a, b, c y d. Donde, la potencia requerida de generación se considera como variable independiente y se realiza el cálculo iterativo con aproximaciones sucesivas desde el límite inferior, e incrementando el flujo de combustible de manera gradual, hasta que el programa alcance la potencia del ciclo térmico requerida. En cada iteración, el programa determina las características de las variables de control en la planta termoeléctrica como son: el flujo de agua de alimentación, el flujo de combustible a la cámara de combustión, la cantidad de gases de recirculación, la presión del domo de vapor, la presión de vapor recalentado, se establece las presiones de extracción de la turbina de alta y baja presión, así como la presión de operación del condensador. En el capítulo I se presenta el estado del arte del diseño de equipo térmico, de los modelos de simulación por primera y segunda ley de la termodinámica y de los modelos exergéticos y Termoeconómicos. En el capítulo II, se plantean las generalidades sobre las instalaciones de producción de ponencia mediante vapor, se analizan las diferentes configuraciones del ciclo Rankine, se muestran las características de construcción y operación de la central térmica de vapor Villa de Reyes conocidas, en especial las características geométricas de los elementos que integran al generador de vapor. En el capitulo III, se presentan las metodologías de los cálculos termodinámicos y de la transferencia de calor de que se llevan a cabo en el hogar y las superficies intercambiadoras del generador de vapor. Metodologías que se emplean para determinar las propiedades termodinámicas de los fluidos de trabajo (vapor, gases de combustión), en cada uno de los En el capítulo IV, se presentan los fundamentos teóricos de los análisis Exergéticos y Termoeconómicos y la metodología del costo nivelado de generación que es la base del análisis termoeconómico realizado a la central termoeléctrica Villa de Reyes. En el capítulo V, se presentan los resultados del analíticos del cálculo térmico del hogar del generador de vapor a cargas parciales (100%, 75%, 50% y 25%), la validación de la transferencia de calor en las superficies intercambiadoras del generador de vapor, el análisis del ciclo termodinámico de la central térmica, obteniendo la eficiencia total del ciclo y finalmente, se presentan los resultados del análisis exergético y termoeconómico a carga variable, del análisis termoeconómico y los resultados del análisis de sensibilidad aplicado al modelo de la central termoeléctrica Villa de Reyes. En el capítulo VI, se presentan las conclusiones y las recomendaciones a la presente investigación, así como los futuros estudios que se desprenden en base a los resultados obtenidos en el presente trabajo. elementos que integran el generador de vapor.
Cerda, Escobar Daniel Martín. "Análisis mecánico del efecto sísmico en el piping interior de una caldera en una central térmica". Tesis, Universidad de Chile, 2017. http://repositorio.uchile.cl/handle/2250/146423.
Texto completoUn estudio reciente de modelación sísmica de una caldera ha detectado posibles colisiones entre sus elementos interiores. En particular, los haces de tubos que operan en la etapa de sobrecalentamiento y recalentamiento, chocan contra las paredes laterales de la caldera, durante un sismo. Dada la envergadura de la estructura y considerando también las condiciones de operación, no se tiene certeza de cuáles serían los efectos que puede originar el impacto de los tubos interiores. Es por este motivo, que el objetivo principal de este trabajo consiste en plantear una estrategia de solución al eventual problema de choque. La metodología utilizada considera un modelo computacional de tubos cuyo diseño se asemeja en mayor medida a aquel indicado en los planos mecánicos de la caldera. Además, su respuesta dinámica obedece a parámetros sísmicos cuyas solicitaciones son más exigentes, de acuerdo a lo establecido por la norma de diseño sísmica chilena. Para determinar el máximo desplazamiento del haz de tubos durante un sismo, estos son excitados mediante una aceleración sinusoidal, cuya amplitud y frecuencia representa el movimiento del techo de la caldera. Sumada a esta respuesta armónica de los tubos, que superpone los máximos modales, se añade el ángulo de rotación que sufren al nivel de su anclaje con el techo de la caldera. Los resultados indican que es altamente probable que ocurra una colisión entre los tubos de agua y las paredes laterales de la caldera, ya que el desplazamiento máximo que sufre la parte inferior del haz de tubos supera la holgura disponible. Para evaluar la magnitud del impacto, se utiliza la teoría desarrollada para el contacto entre superficies sólidas (esféricas). Donde a partir de la energía almacenada como deformación elástica en el haz de tubos, se determina el trabajo de compresión que realiza la fuerza de impacto, de acuerdo al número de tubos en contacto. Los resultados advierten que el daño no es despreciable. Se estima que la fuerza de impacto entre el tubo de agua y el tubo de pared podría alcanzar los 155 [kN], desarrollando un comportamiento en el rango plástico. Sin bien es cierto que difícilmente ocurra una ruptura catastrófica, el daño local puede ser un sitio de inicio de corrosión, causando problemas de mediano a largo plazo. Una posible solución a este problema consiste en evitar el contacto entre tubos, al interponer una placa en la trayectoria de éstos, mitigando la deformación plástica local.
PEREIRA, Adriano Fernandes. "Procedimentos de avaliação de esforços torcionais em centrais termelétricas que operam em ciclo combinado gás-vapor". reponame:Repositório Institucional da UNIFEI, 2010. http://repositorio.unifei.edu.br/xmlui/handle/123456789/1413.
Texto completoMade available in DSpace on 2018-06-26T18:08:43Z (GMT). No. of bitstreams: 1 dissertacao_0036180.pdf: 2465256 bytes, checksum: 0e53e3be24cf2865f30c3d0c3a899754 (MD5) Previous issue date: 2010-04
Manobras em sistemas elétricos de potência, especialmente relacionadas a linhas de transmissão, são frequentes e importantes para manter um grau de confiabilidade e uma adequada condição de operação para os mesmos. Quando se trata de sistemas interligados com a presença de geração termelétrica, tais manobras podem acarretar severos esforços torcionais nos eixos de suas unidades geradoras e, consequentemente causar danos irreversíveis por estresse mecânico, como fadiga e perda de vida útil. O presente trabalho propõe procedimentos de avaliação de esforços torcionais nos eixos de centrais termelétricas que operam em ciclo combinado gás vapor, decorrentes da prática de religamentos automáticos de linhas de transmissão, através da utilização de técnicas complementares como técnicas de análise modal, critérios simplificados e critérios mais aprofundados com programas de transitórios eletromagnéticos. Com esses procedimentos e uma ação conjunta com os fabricantes dos turbogeradores pretende-se apresentar uma forma de avaliar os esforços torcionais nos eixos das unidades geradoras com o intuito de permitir a utilização de religamentos automáticos de linhas de transmissão sem ocasionar danos aos equipamentos.
Caruso, Roberto. "Propagation of Hydrogen Air Vapor Flame in presence of Water Droplets". Thesis, Orléans, 2019. http://www.theses.fr/2019ORLE2002.
Texto completoThe Fukushima accident in 2011 highlighted the serious consequences that an explosion of a hydrogen-based gas mixture has on installations and the environment. In this accident, the complete destruction of Reactor 2 resulted in a significant release of radioactive dust into the atmosphere with serious environmental consequences that are still under investigation. A thorough knowledge of the propagation of a hydrogen flame in a confined environment is essential to understand the transition conditions between deflagration and flame detonation regimes that can compromise the integrity of the reactor building. One aspect of the aspects that has been little studied concerns the impact that the activation of cooling water jets can have on the severity of an explosion. The purpose of this thesis work is to better understand the role of water spray injection on the combustion regimes of hydrogen-air mixtures (propagation rates and pressure loading) in a confined space. This research work began with a preliminary study to evaluate the impact of the presence of water vapour on laminar velocity and flame thickness. Subsequently, an experimental study was carried out at the ICARE-CNRS Orléans laboratory in an ENACCEF 1 vertical acceleration tube (internal volume 720 l). To conduct this study, different hydrogen/air mixtures were selected, representative of different combustion regimes, to investigate the impact of water spray on an ascending and descending flame. All the work constitutes a useful experimental database for the validation of CFD codes used in the safety assessment of nuclear installations
Marques, Frederico Augusto Spolidorio. "Implementação e validação pratica de modelos multidisciolinares abordados em uma central de co-geração de energia eletrica". [s.n.], 2007. http://repositorio.unicamp.br/jspui/handle/REPOSIP/259510.
Texto completoDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação
Made available in DSpace on 2018-08-10T03:25:09Z (GMT). No. of bitstreams: 1 Marques_FredericoAugustoSpolidorio_M.pdf: 3699527 bytes, checksum: fee04cbb6876f5ce62626058ebc660e7 (MD5) Previous issue date: 2007
Resumo: Este projeto busca relacionar diversos aspectos interdisciplinares envolvidos em uma central de co-geração de energia elétrica. Motivado pela crescente inserção de centrais de geração distribuída operando de forma ilhada ou paralela ao sistema, foram desenvolvidos modelos mecânicos (térmicos e dinâmicos) e elétricos buscando representar os diversos equipamentos envolvidos em uma central de geração em um nível industrial. Baseado nesta concepção, optou-se pela geração de energia através de máquinas térmicas (turbinas a vapor) impulsionadas pela energia proveniente da queima de biomassa restante de diferentes processos industriais. Os modelos teóricos aqui representados foram numericamente simulados com parâmetros obtidos em um estudo de caso real. Seus resultados foram então comparados qualitativamente e quantitativamente contra as variáveis reais do processo analisado. Ao consolidar esta ferramenta de estudo, o simulador mostrou-se eficiente no treinamento de operadores de casas de forças, sendo capaz de esclarecer as interferências entre o nível de carga com as demais variáveis envolvidas em seu processo
Abstract: This project intends to gather several interdisciplinary aspects common to a co-generation power plant. Driven by the increasing amount of distributed generation units operating on island or parallel mode with the network, some mechanical (thermo and dynamic) and electrical models were developed in order to represent the equipments usually installed on an industrial size power station. Based on this concept, the more convenient option was to proceed the evaluation through turbo machinery (steam turbine) driven by the energy acquired from the heat power on burning byproducts of industrial processes. The theoretical models were simulated with parameters obtained from a real case study. The results were then finally compared with real process information acquired from field research. In order to consolidate this computational tool, the simulator has shown efficient results on training power station operators on clarifying the impacts of load level on the other relevant variables on their processes
Mestrado
Energia Eletrica
Mestre em Engenharia Elétrica
LOPEZ, LUIZ A. N. M. "Transformadas de Wavelets e logica Fuzzi na inspecao por Eddy-Current em tubos de geradores de vapor de centrais nucleares". reponame:Repositório Institucional do IPEN, 2002. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11012.
Texto completoMade available in DSpace on 2014-10-09T14:09:44Z (GMT). No. of bitstreams: 1 09057.pdf: 12808764 bytes, checksum: 970b3a8c12068b9ea0e88948bbcda318 (MD5)
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
Chiok, Valle Luis Martin. "Análisis energético y exergético de la implementación del ciclo combinado en la central térmica de Santa Rosa". Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2014. https://hdl.handle.net/20.500.12672/12765.
Texto completoEl objetivo general del presente trabajo es efectuar una evaluación energética y exergética de la implementación de un ciclo combinado en la central térmica de Santa Rosa, ubicada en la ciudad de Lima, con el objetivo de estimar la viabilidad técnica del proyecto.
Trabajo de suficiencia profesional
Chen, Danying. "Revêtements multicouches à base de nitrure d'aluminium pour les récepteurs des systèmes solaires à concentration". Thesis, Université Grenoble Alpes (ComUE), 2019. http://www.theses.fr/2019GREAI079.
Texto completoThere is an increasing interest for concentrated solar power (CSP) systems which can work at temperatures higher than 1000 °C to optimize efficiency. One of the challenges is to design the receiver that will be heated at high temperature in air. Compared to coatings in gas turbine engine, the coating(s)/substrate system must have a high thermal conductivity to ensure a good heat transfer to the fluid. Aluminum nitride (AlN) coating, deposited by chemical vapor deposition at 1100-1200 °C at a growth rate of 10-50 µm·h-1, is selected for its high thermal conductivity, low thermal expansion coefficient, high temperature stability and its ability to develop stable alumina scales above 1000 °C. Molybdenum-based alloys are selected as substrate materials for their excellent thermal and mechanical properties. The alumina-forming iron-based alloys are also chosen as model substrates to reduce the influencing parameters in real-life receivers and to study the potential of these coatings. Accelerated cyclic oxidation tests and emissivity measurements allow the evaluation of AlN coatings as materials for high temperature CSP receivers. The multilayered systems exhibit low degradation after hundreds of thermal cycles at 800 °C in air and can support higher temperatures (1100 °C) for 100 to 500 h depending on the coating thickness. Nevertheless, the fast cyclic oxidation in solar furnace leads to cracks through the coatings. An analytical model is developed to study the stress evolution within the coating(s)/substrate system. Calculated results are in good agreement with experimental data. The measurements of the optical properties reveal a decrease of absorptivity after oxidation for AlN coatings, but a significant increase of absorptivity when SiC coating is added as a top layer
Evin, Harold. "Low Cr alloys with an improved high temperature corrosion resistance". Thesis, Dijon, 2010. http://www.theses.fr/2010DIJOS082/document.
Texto completoThe improvement of high temperature oxidation resistance of low chromium content steels, such as T/P91, is of great interest in regards with their application in thermal power generating plants. Indeed, they possess good creep properties, and low thermal expansion coefficient. Important needs in energy together with environmental issues place power generation plants under constraints which lead to develop high efficiency systems. A usual way to increase the efficiency consists in increasing temperature and pressure parameters of the power generating plant. Studies has shown that the total efficiency of a plant increases by nearly 8 % when changing the steam parameters from 538°C/18.5 MPa to 650°C/30 MPa. Then, the problem of corrosion resistance of 9% chromium steel in those conditions is asked. In this work, the behavior of a ferritic / martensitic 9% chromium steel has been studied at 650°C in dry air and in water vapor containing environment in both isothermal and thermal cyclic conditions. The weight gain of samples provides information on the kinetics of the oxidation reaction and the adhesion of formed oxide scale. Corrosion products were characterized by several analytical techniques in order to identify oxides with accuracy and to understand their formation mechanisms. Mixed iron and chromium oxides (Cr, Fe) 2O3 are initially formed and provide temporary protection to the substrate. For long time exposure or temperatures above 650°C, magnetite, Fe3O4 and hematite Fe2O3 are the main oxides formed, highlighting the fact that low chromium steel are inappropriate for applications in such drastic conditions. In order to increase the high temperature corrosion resistance of this alloy, various solutions have been proposed as aluminizing by pack cementation, reactive element oxides coatings of by MOCVD, or addition of alloying elements in the steel composition. These solutions were then tested at 650 ° C in dry air and in water vapor environments
Robach, Odile. "Étude in situ de la croissance de Ag sur MgO(001) et de Ni/Ag(001), et étude de la nitruration du GaAs par diffusion de rayons X en incidence rasante". Université Joseph Fourier (Grenoble ; 1971-2015), 1997. http://www.theses.fr/1997GRE10226.
Texto completoMurmanskii, Ilia. "Improvement and design of ejectors for steam turbines and chillers". Doctoral thesis, 2019. http://hdl.handle.net/2158/1173185.
Texto completoFerreira, Rúben Dinis Gonçalves. "Aumento da produção de energia de uma turbina de vapor numa Central Termoeléctrica". Master's thesis, 2016. http://hdl.handle.net/10400.26/16675.
Texto completoRuiz, Martínez José Tomás. "Nuclearización de un procedimiento químico de disolución de magnetita en el lado secundario de generadores de vapor en centrales nucleares". Doctoral thesis, 2020. http://hdl.handle.net/10251/149497.
Texto completo[EN] Steam generators in pressure-water nuclear power plants, often exhibit significant clogging and fouling over time due to the deposition of corrosion products resulting from the secondary circuit.The obstruction of the free parts constitutes the main mass of the deposits present in the steam generators. These fouling and clogging phenomena modify the thermo-hydraulic and vibratory behavior of steam generators with consequences in terms of safety, reactor performance and life-time potential. A preventive chemical cleaning of the secondary circuit of the steam generator is carried out to keep it in a state of cleanliness that guarantees operation for several cycles and ensures near-manufacturing performance.Certain steam generators present a degree of fouling and significant clogging in addition to the deposits of the corrosion products from the secondary circuit. The deposits are located mainly in the following parts of the secondary of a Steam Generator: ¿ On the different sheets in the form of sludge that can form locally very hard shells, ¿ In the area of circulation of the tubes, ¿ In the common zone of the secondary elements of the Steam Generator (vessel, beam envelope, etc.) ¿ In the spaces (interstices) located between the tubes and the sheets until they fill them completely ¿ In the foliar steps of the water sheets until completely closing them. The main objective of this thesis is the "nuclearization" of the basic process of chemical cleaning of boilers. Understanding as such the adaptation of the procedure to the nuclear environment so that it meets the criteria of efficiency in disposal of deposits, without endangering the integrity of the steam generator. The chemical method is based on a "soft" chemical cleaning, meaning the use of chemical solutions to partially dissolve the deposits (magnetite, cinc oxides and copper), and limiting the corrosion of pressurized materials and internal elements. Chemical solutions and associated rinses cover the tubular sheet, the flow partition sheet and the intermediate sheet assembly, the entire tubular bundle and the lower internal structures. This thesis shows the part of laboratory tests in scale models that have led to the final definition of a method that has been carried out to full scale practice with satisfactory results and which constitutes an advantage for Electricité de France ( EdF) both from the technical and economical point of view .
[CA] Els generadors de vapor de les centrals nuclears d'aigua a pressió solen presentar, amb el pas del temps, una obstrucció i un embrutiment important a causa del dipòsit dels productes de corrosió resultants del circuit secundari. L'obstrucció de les parts lliures constitueix la massa principal dels dipòsits presents en els generadors de vapor. Aquests fenòmens d'embrutiment i obstrucció en modifiquen el comportament termo-hidràulic i vibratori amb conseqüències en termes de seguretat, rendiment del reactor i del potencial de durada de vida. Es realitza doncs, una neteja química preventiva del circuit secundari del generador de vapor per mantenir-lo en un estat de neteja que en garanteix el funcionament, durant diversos cicles, i n'assegura un rendiment pròxim al de fabricació. Alguns generadors de vapor tenen un grau d'embrutiment i rebliment important unit als dipòsits dels productes de corrosió procedents del circuit secundari. Els dipòsits es localitzen principalment en les següents parts del secundari d'un generador de vapor: ¿ sobre les diferents plaques en forma de fangs que poden formar localment closques molt dures ¿ a la zona de circulació dels tubs, ¿ a la zona comuna dels elements del secundari del generador de vapor (vas, envoltant del feix, etc.) ¿ en els espais (intersticis) situats entre els tubs i les plaques, fins que els omplen completament ¿ en els passos foliars de l'aigua de les plaques fins a reblir-los completament. L'objectiu principal d'aquesta tesi és la "nuclearització" del procediment base de neteja química de calderes; tot entenent com a tal, l'adaptació del procediment a l'entorn nuclear de manera que complesca amb el criteri d'eficàcia pel que fa a l'eliminació de dipòsits, sense posar en risc la integritat del generador de vapor. El procediment químic es basa en una neteja química "suau", entenent-se com a tal la utilització de solucions químiques per dissoldre parcialment els dipòsits (magnetita, òxids de cinc i de coure), la qual cosa limita la corrosió dels materials pressuritzats i dels elements interns. Les solucions químiques i les esbandides associats recobreixen la placa tubular, la placa de repartiment de cabal i el conjunt de plaques intermèdies, el feix tubular per complet i les estructures internes inferiors. En aquesta tesi es mostra la part d'assajos de laboratori en maquetes que ha portat a la definició final d'un procediment que s'ha dut a terme en la pràctica i a escala real, amb resultats satisfactoris. Fet que constitueix un avantatge per Electricité de France (EdF) tant des del punt de vista tècnic com econòmic.
Ruiz Martínez, JT. (2020). Nuclearización de un procedimiento químico de disolución de magnetita en el lado secundario de generadores de vapor en centrales nucleares [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/149497
TESIS
Aveiro, Nuno Miguel Filipe. "Monitorização e otimização dos condicionamentos químicos aplicados no circuito água-vapor e no circuito de refrigeração principal da Central Termoelétrica de Lares". Master's thesis, 2018. http://hdl.handle.net/10362/54182.
Texto completoBento, Fábio André de Oliveira. "Parallelization and implementation of methods for image reconstruction". Master's thesis, 2013. http://hdl.handle.net/10400.6/3702.
Texto completoAlgoritmos de reconstrução algébrica são algoritmos iterativos que são usados em muitas áreas incluindo medicina, sismologia ou meteorologia. Estes algoritmos são conhecidos por serem bastante exigentes computacionalmente. Isto pode ser especialmente complicado para aplicações de tempo real ou quando processados por computadores pessoais de baixo custo. Uma destas aplicações de tempo real é a reconstrução de imagens de vapor de água a partir de observações de sistemas globais de navegação por satélite. A paralelização dos algoritmos de reconstrução algébrica permite que se reduza significativamente os requisitos computacionais permitindo obter soluções válidas para previsão meteorológica num curto espaço de tempo. O principal objectivo desta dissertação é apresentar e analisar diversas bibliotecas e técnicas multithreading para a reconstrução algébrica em CPU e GPU. Foi concluído que a paralelização compensa sobre a implementações sequenciais. De um modo geral as implementações GPU obtiveram resultados relativamente melhores que implementações em CPU, isto dependendo do tamanho do problema a ser estudado. Um objectivo secundário era desenvolver uma aplicação que realizasse a reconstrução de imagem de vapor de água através de sistemas globais de navegação por satélite de uma forma paralela. Este software tem sido desenvolvido com sucesso e diversos testes foram realizados com dados sintéticos e dados reais, os resultados preliminares foram satisfatórios. Esta dissertação foi escrita no Space & Earth Geodetic Analysis Laboratory (SEGAL) e foi realizada de acordo com o projecto Structure 01' Moist convection in high-resolution GNSS observations and models (SMOG) (PTDC / CTE-ATM/ 11992212010) financiado pelo FCT.
Fundação para a Ciência e a Tecnologia (FCT)
Macário, Marco Cláudio Torres. "Evaluation of Simplified Nuclear Power Plant Simulator in Case of a Main Steam Line Break". Master's thesis, 2016. http://hdl.handle.net/10316/81591.
Texto completoNesta dissertação é apresentada a simulação simplificada de uma rutura na conduta principal de vapor de uma central nuclear de dois circuitos de permutação de calor e reator de água pressurizada. O modelo de central usado neste trabalho, é um modelo genérico de uma central de água pressurizada com dois circuitos de permutação de calor, com geradores de vapor de tipo tubo em U invertido e com sistema de contenção do reator, seco. Com uma potencia térmica de aproximadamente 1800 MWt (600 MWe).As simulações foram realizadas usando o software Personal Computer Transient Analyser (PCTran), utilizando todos os parâmetros genéricos para este tipo de reator e focando-se numa rutura na conduta principal de vapor, que é um dos acidentes de base de projeto, com o qual a central pode normalmente suportar.Esta dissertação é baseada em duas simulações principais, uma rutura pequena de diâmetro 4,4 inch (11,3 cm), e uma maior de cerca de 14 inch (35,7 cm).Durante as simulações podemos observar todos os valores dos parâmetros que caracterizam o transitório e o seu timing, desde o inicio do evento passando pelo desligamento de emergência do reator e também todos as ocorrências principais depois do mesmo ser desligado.Também é feita uma comparação entre as duas simulações, para perceber as diferenças entre cada cenário.Adicionalmente são feitas comparações entre as simulações obtidas e simulações similares realizadas com códigos de computador mais detalhados, que são efetivamente utilizadas para análise de segurança.A conclusão principal obtida depois destas duas simulações é de que os sistemas de segurança atuam como esperado. Os sistemas de refrigeração de emergência que têm como função remover o calor residual que continua a ser produzido depois do reator ser desligado entram em ação, ficando a central nas devidas condições de segurança.Os resultados da analise mostram que o simulador simplificado pode ser usado efetivamente para fins educativos.Aquando da rutura maior, as variações em parâmetros como temperaturas (Cold Leg e Hot Leg), fluxo de vapor nos geradores de vapor, pressões e por fim a reatividade, são mais rápidas quando comparado com a rutura pequena. Consequentemente, o desligamento do reator é iniciado mais cedo do que no caso da rutura pequena. Os parâmetros principais têm comportamento semelhante ao das analises de segurança. Existem pequenas diferenças nos valores de alguns parâmetros, mas globalmente durante os intervalos de tempo observados, as curvas são similares as mesmas na analise de segurança.
This thesis presents a simplified simulation of a main steam line break (MSLB) in a nuclear power plant with two loops and a pressurized water reactor (PWR). The plant model used in this work is a generic two-loop PWR with inverted U-bend steam generators and dry containment system, with thermal output in the neighbourhood of 1800 MWt (600 MWe).The simulations are conducted by using the software Personal Computer Transient Analyser (PCTran) using all the default parameters for this kind of reactor focusing to a steam line break, which is one of design basis accidents, which the plant can normally withstand.The thesis is based on two main simulations, a small steam line break with diameter of 4,4 inch (11,3 cm), and a larger with 14 inch (35,7 cm).During the simulations we can observe the values of parameters that characterise the transient and its timing, from the beginning of the event through the reactor trip and all the main events after the reactor trip. A comparison is made between the two simulations, to understand the differences in each scenario.In addition, the comparisons are made between the obtained simulations and the similar simulations performed with more detailed computer codes, which are actually used for safety analysis.The main conclusion after these two simulations is that the safety systems act as expected. The emergency cooling systems that have the purpose of removing decay heat after the reactor shutdown went into action, so the plant remains in a safe condition.The results of the analysis show that simplified simulator can be effectively used for education purposes.At the larger break, the timely changes of parameters like temperatures (Cold Leg and Hot Leg), steam flow in the SGs, pressures and in the end reactivity are faster as it is the case of the smaller break. Consequently, the reactor trip is initiated sooner as it is the case of the smaller break. The main parameters behave similarly as they do in safety analysis. Small differences exist in values of certain parameters, but their overall curves over the observed time intervals are similar to their respective curves in the safety analysis.This is confirmed by comparison of the general shapes of the main parameters, which change through the time, and are similar comparing the results of simplified simulator and the results of the detailed computer code, which is used for the safety analysis.The main conclusion after these two simulations is that the safety systems are effective for achieving an automatic plant safety state, as expected, and all the emergency core cooling systems that remove the decay heat after the shutdown went into action.