Academic literature on the topic 'Поточна холодопродуктивність'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Поточна холодопродуктивність.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Поточна холодопродуктивність"

1

Трушляков, Євген Іванович, Андрій Миколайович Радченко, Микола Іванович Радченко, Ян Зонмін, Анатолій Анатолійович Зубарєв, and Веніамін Сергійович Ткаченко. "ХОЛОДОПРОДУКТИВНІСТЬ СИСТЕМИ КОНДИЦІЮВАННЯ ЗОВНІШНЬОГО ПОВІТРЯ ЗА ПОТОЧНИМ ТЕПЛОВИМ НАВАНТАЖЕННЯМ." Aerospace technic and technology, no. 2 (April 22, 2019): 51–55. http://dx.doi.org/10.32620/aktt.2019.2.06.

Full text
Abstract:
The efficiency of the outdoor air conditioning systems application depends on how full the installed cooling capacity is applied, that is, with a more complete load and for as long as the possible yearly duration in actual climatic conditions. The production of cold is taken as a criteria of a quantitative evaluation of the efficiency of applying the cooling capacity of air conditioning systems – the amount of cold produced in accordance with its current demand for air conditioning, which in turn depends on the current consumption of cooling capacity and its duration and equals to their multiplication. It is obvious that the maximum value of the current amount of cold produced/consumed indicates an effective application of the installed cooling capacity. However, since the current demands of cooling capacity and their duration, that is, the amount of cold produced/consumed, depending on the changing current climatic conditions, they are characterized by significant fluctuations, which makes it difficult to choose the installed cooling capacity of the air conditioning system. Obviously, if we determine the amount of cold produced/consumed by its current values and summarized during the year, it is possible to significantly simplify the choice of the installed cooling capacity. At the same time, the current amount of cold produced/consumed causes a change in the rate of increment of the annual cold production with a change in the installed cooling capacity, and the maximum rate corresponds to the installed cooling capacity, which provides its efficient use. Proceeding from a different rate of increment of annual cold production with an increase in the installed cooling capacity of the air conditioning system due to a change in heat load in accordance with current climatic conditions during the year, the value of design heat load on the air conditioning system (installed cooling capacity) that provides maximum or close to it the rate of increment of the annual production of cold, and hence the maximum efficient use of installed cooling capacity is chosen
APA, Harvard, Vancouver, ISO, and other styles
2

Радченко, Андрій Миколайович, Ян Зонмін, Микола Іванович Радченко, Сергій Анатолійович Кантор, Богдан Сергійович Портной, and Юрій Георгійович Щербак. "ВИЗНАЧЕННЯ ВСТАНОВЛЕНОЇ ХОЛОДОПРОДУКТИВНІСТІ СИСТЕМИ ОХОЛОДЖЕННЯ ПОВІТРЯ НА ВХОДІ ГАЗОТУРБІННОЇ УСТАНОВКИ ЗА ПОТОЧНИМ ТЕПЛОВИМ НАВАНТАЖЕННЯМ." Aerospace technic and technology, no. 2 (April 22, 2019): 56–60. http://dx.doi.org/10.32620/aktt.2019.2.07.

Full text
Abstract:
Significant fluctuations of the current temperature and relative humidity of the ambient air lead to significant changes in the thermal load on the cooling system at the inlet of gas turbine units (GTU), which acutely raises the problem of choosing their installed (design) thermal load. Calculations of ambient air cooling processes were carried out for different climatic conditions, for example, southern Ukraine (Mykolaiv) and Central China (Beijing). It is analyzed two methods of determination of the installed (design) cooling capacity of the ambient air cooling system at the GTU inlet according to the maximum current reduction of fuel consumption and according to the maximum rate (increase) of annual reduction of fuel consumption following to increasing of the installed cooling capacity, calculated by summarizing the current values of fuel consumption reduction. It is shown that the values of the installed cooling capacity of the air cooling system at the GTU inlet, determined by both methods, are close enough but differ significantly for different climatic conditions. The advantage of the method of calculating the installed cooling capacity of the air cooling system at the GTU inlet according to the maximum rate of annual reduction in fuel consumption is the possibility of a more precise definition of it due to the absence of significant fluctuations in the annual reduction in fuel consumption, calculated by summarizing the current values of fuel consumption reduction. Since the maximum reduction in fuel consumption per year is achieved with some decrease in the rate of its increment at high values of the design cooling capacity, required in the hottest hours in the summer and excessive in somewhat cool periods (at night and in the morning even in the summer), the installed cooling capacity, determined according to the maximum rate of the reduction of fuel consumption, will be insufficient in times of increased thermal loads above their design value. In such cases, the elimination of the deficit in cooling capacity is possible by using an excess of cold accumulated during reduced thermal loads
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Поточна холодопродуктивність"

1

Trushliakov, E., A. Radchenko, M. Radchenko, S. Kantor, O. Zielikov, Є. Трушляков, А. Радченко, М. Радченко, С. Кантор, and А. Зеліков. "The efficiency of refrigeration capacity regulation in ambient air conditioning systems." Thesis, 2020. http://eir.nuos.edu.ua/xmlui/handle/123456789/4345.

Full text
Abstract:
The efficiency of refrigeration capacity regulation in ambient air conditioning systems = Ефективність регулювання холодопродуктивності в системах кондиціювання зовнішнього повітря / E. Trushliakov, A. Radchenko, M. Radchenko, S. Kantor, O. Zielikov // Матеріали XI міжнар. наук.-техн. конф. "Інновації в суднобудуванні та океанотехніці". В 2 т. – Миколаїв : НУК, 2020. – Т. 1. – С. 475–480.
Розроблено новий метод і підхід до аналізу ефективності системи кондиціювання зовнішнього повітря, згідно з яким весь діапазон змінних теплових навантажень поділяється на дві зони: зона обробки навколишнього повітря зі значними коливаннями поточного теплового навантаження і зона без коливань. Пропонований спосіб регулювання холодопродуктивності дозволяє підвищити ефективність використання встановленої холодопродуктивності в поточних кліматичних умовах.
Abstract. A new method and approach to analyzing the efficiency of ambient air conditioning system has been developed, according to which the overall range of changeable heat loads is divided in two zones: the zone of ambient air processing with considerable fluctuations of the current heat load and a zone without fluctuations. The proposed method of the refrigeration capacity regulation allows to increase the efficiency of utilizing the installed refrigeration capacity in current climatic conditions.
APA, Harvard, Vancouver, ISO, and other styles
2

Трушляков, Є. І., А. М. Радченко, А. А. Зубарєв, В. С. Ткаченко, Я. Зонмін, С. Г. Фордуй, E. I. Trushliakov, et al. "Визначення встановленої холодопродуктивності системи кондиціювання зовнішнього повітря за поточними тепловими навантаженнями." Thesis, 2019. http://eir.nuos.edu.ua/xmlui/handle/123456789/4328.

Full text
Abstract:
Визначення встановленої холодопродуктивності системи кондиціювання зовнішнього повітря за поточними тепловими навантаженнями = Determining cooling capacity of ambient air conditioning system according to current heat loads / Є. І. Трушляков, А. М. Радченко, А. А. Зубарєв, В. С. Ткаченко, Я. Зонмін, С. Г. Фордуй // Матеріали X міжнар. наук.-техн. конф. "Інновації в суднобудуванні та океанотехніці". В 2 т. – Миколаїв : НУК, 2019. – Т. 1. – С. 447–451.
Анотація. Ефективність застосування систем кондиціювання зовнішнього повітря залежить від того, наскільки повно використовуються встановлені холодильні потужності в конкретних кліматичних умовах, тобто за більш повного навантаження і тривалого часу упродовж року. За показник кількісної оцінки ефективності використання холодильної потужності систем кондиціювання повітря взято виробництво холоду – кількість виробленого холоду відповідно до його поточних витрат на кондиціювання повітря, яка в свою чергу залежить від поточних витрат холодопродуктивності та тривалості роботи системи кондиціювання за цих витрат і представляє собою їх добуток. Вочевидь, що максимальна величина поточної кількості виробленого/витраченого холоду свідчить про ефективне використання встановленої холодильної потужності. Однак, оскільки поточні витрати холодопродуктивності та їх тривалість, тобто кількість виробленого/витраченого холоду, залежать від змінних поточних кліматичних умов, то вони теж характеризуються значними коливаннями, що ускладнює вибір встановленої холодопродуктивності системи кондиціювання повітря. Вочевидь, якщо визначати кількість виробленого/витраченого холоду за його поточними величинами і нарощуванням упродовж року, то можна суттєво спростити вибір встановленої холодопродуктивності. При цьому поточна кількість виробленого/витраченого холоду спричиняє зміну темпу прирощення річного виробництва холоду зі зміною встановленої холодопродуктивності і максимальному темпу відповідає встановлена холодопродуктивність, яка забезпечує її ефективне використання. Виходячи з різного темпу прирощення річного виробництва холоду зі збільшенням встановленої холодопродуктивності системи кондиціювання повітря, обумовленого зміною теплового навантаження відповідно до поточних кліматичних умов упродовж року, вибирають таку величину проектного теплового навантаження на систему кондиціювання повітря (встановлену холодопродуктивність), яка забезпечує максимальний або близький до нього темп прирощення річного виробництва холоду, а відтак і максимальну ефективність використання встановленої холодильної потужності.
Abstract. The efficiency of the use of outdoor air conditioning systems depends on how full the installed cooling capacity is used, that is, with a more complete load and for as long as possible yearly duration in actual climatic conditions. The production of cold is taken as a criteria of a quantitative evaluation of the efficiency of using the cooling capacity of air conditioning systems – the amount of cold produced in accordance with its current demand for air conditioning, which in turn depends on the current consumption of cooling capacity and its duration and equals to their multiplication. It is obvious that the maximum value of the current amount of cold produced/consumed indicates an effective use of the installed cooling capacity. However, since the current demands of cooling capacity and their duration, that is, the amount of cold produced/consumed, depend on the changing current climatic conditions, they are characterized by significant fluctuations, which makes it difficult to choose the installed cooling capacity of the air conditioning system. Obviously, if we determine the amount of cold produced/consumed by its current values and summarized during the year, it is possible to significantly simplify the choice of the installed cooling capacity. At the same time, the current amount of cold produced/consumed causes a change in the rate of increment of the annual cold production with a change in the installed cooling capacity, and the maximum rate corresponds to the installed cooling capacity, which provides its efficient use. Proceeding from a different rate of increment of annual cold production with an increase in the installed cooling capacity of the air conditioning system due to a change in heat load in accordance with current climatic conditions during the year, the value of design heat load on the air conditioning system (installed cooling capacity) that provides maximum or close to it the rate of increment of the annual production of cold, and hence the maximum efficiency use of installed cooling capacity is chosen.
Аннотация. Эффективность применения систем кондиционирования наружного воздуха зависит от того, насколько полно используются установленные холодильные мощности, то есть при более полной нагрузке и в течение как можно более длительного времени в течение года, в конкретных климатических условиях. В качестве показателя количественной оценки эффективности использования холодильной мощности систем кондиционирования воздуха взято производство холода – количество произведенного холода в соответствии с его текущим расходованием на кондиционирование воздуха, которое в свою очередь зависит от текущих затрат холодопроизводительности и продолжительности работы системы кондиционирования при этих затратах и представляет собой их произведение. Очевидно, что максимальная величина текущего количества производимого/затраченного холода свидетельствует об эффективном использовании установленной холодильной мощности. Однако, поскольку текущие затраты холодопроизводительности и их продолжительность, то есть количество производимого/затраченного холода, зависят от меняющихся текущих климатических условий, то они характеризуются значительными колебаниями, что затрудняет выбор установленной холодопроизводительности системы кондиционирования воздуха. Очевидно, если определять количество производимого/затраченного холода по его текущим величинам и наращиванию в течение года, то можно существенно упростить выбор установленной холодопроизводительности. При этом текущее количество производимого/затраченного холода вызывает изменение темпа приращения годового производства холода с изменением установленной холодопроизводительности, и максимальному темпу соответствует установленная холодопроизводительность, которая обеспечивает ее эффективное использование. Исходя из разного темпа, приращение годового производства холода с увеличением установленной холодопроизводительности системы кондиционирования воздуха, обусловленного изменением тепловой нагрузки в соответствии с текущими климатическими условиями в течение года, выбирают такую величину проектной тепловой нагрузки на систему кондиционирования воздуха (установленную холодопроизводительность), которая обеспечивает максимальный или близкий к нему темп приращения годового производства холода, а значит и максимальную эффективность использования установленной холодильной мощности.
APA, Harvard, Vancouver, ISO, and other styles
3

Трушляков, Є. І., А. М. Радченко, Б. С. Портной, С. Г. Фордуй, E. I. Trushliakov, A. M. Radchenko, B. S. Portnoi, and S. G. Forduy. "Методи визначення теплового навантаження систем кондиціювання повітря з урахуванням поточних кліматичних умов." Thesis, 2019. http://eir.nuos.edu.ua/xmlui/handle/123456789/4332.

Full text
Abstract:
Методи визначення теплового навантаження систем кондиціювання повітря з урахуванням поточних кліматичних умов = Methods to determine the heat load of air conditioning systems with account of current climatic conditions / Є. І. Трушляков, А. М. Радченко, Б. С. Портной, С. Г. Фордуй // Матеріали X міжнар. наук.-техн. конф. "Інновації в суднобудуванні та океанотехніці". В 2 т. – Миколаїв : НУК, 2019. – Т. 1. – С. 493–497.
Анотація. Одним з найбільш привабливих резервів підвищення енергетичної ефективності систем кондиціювання повітря є забезпечення роботи холодильних компресорів в номінальному або близькому до номінального режимах шляхом вибору раціонального проектного теплового навантаження та його розподілу в межах його проектної величини відповідно до характеру поточного теплового навантаження за змінних поточних кліматичних умов з метою максимального або близького до нього річного виробництва холоду відповідно до його витрат на кондиціювання повітря. В загальному випадку весь діапазон поточних теплових навантажень будь-якої системи кондиціювання повітря включає діапазон нестабільних навантажень, пов’язаних з попереднім охолодженням зовнішнього повітря зі значними коливаннями витрат холодопродуктивності відповідно до поточних кліматичних умов, і порівняно стабільну частку холодильної потужності, що витрачається на подальше зниження температури повітря від певної порогової температури до кінцевої температури на виході. Цілком очевидно, що стабільний діапазон теплового навантаження може бути забезпечений при роботі звичайного компресора в режимі, близькому до номінального режимі, тоді як попереднє охолодження зовнішнього повітря зі значними коливаннями теплового навантаження потребує регулювання холодопродуктивності шляхом застосування компресора з регульованою швидкістю. Таким чином, за характером зміни поточних теплових навантажень будь-яка система кондиціювання повітря, чи то центральна система кондиціювання повітря з його тепловологісною обробкою в центральному кондиціонері, чи то її комбінація з місцевою рециркуляційною системою кондиціювання повітря в приміщеннях, по суті, складається з двох підсистем: попереднього охолодження зовнішнього повітря і його подальшого охолодження до встановленої кінцевої температури. Запропонований метод розподілу проектного теплового навантаження в залежності від характеру поточних теплових навантажень є корисним для раціонального проектування систем центрального кондиціювання повітря та їх комбінованих версій з місцевою системою кондиціювання повітря.
Abstract. One of the most attractive reserves for improving the energy efficiency of air conditioning systems is to ensure the operation of refrigeration compressors in nominal or close to nominal modes by selecting a rational design heat load and distributing it within its design value according to the behavior of the current heat load under variable current climatic conditions to provide the maximum or close to maximum annual cooling capacity generation accord-ing to cooling duties of air conditioning. In the general case, the overall range of current thermal loads of any air conditioning system includes a range of unstable loads associated with the precooling of ambient air with significant fluctuations in cooling capacity according with current climatic conditions, and a relatively stable range of cooling capacity consumed to further reduce air temperature from a certain threshold temperature to the final outlet tem-perature. It is quite obvious that a stable range of heat load can be ensured within operating a conventional com-pressor in a mode close to the nominal mode, while precooling the ambient air with significant fluctuations in heat load requires regulation of the cooling capacity through the use of a variable speed compressor. Thus, in response of the behavior of the change in current heat loads, any air conditioning system, whether the central air-conditioning system with its heat procession in a central air conditioner, or a combination thereof with a local recirculation sys-tem of indoor air, essentially consists of two subsystems: pre-cooling the ambient air and then cooling it to the set point temperature. The proposed method of distribution of design heat load depending on the behaviour of current heat load is useful for the rational design of central air conditioning systems and their combined versions with the local air conditioning system.
Аннотация. Одним из самых привлекательных резервов повышения энергетической эффективности систем кондиционирования воздуха является обеспечение работы холодильных компрессоров в номинальном или близком к номинальному режимах путем выбора рационального проектной тепловой нагрузки и ее распределения в пределах ее проектной величины в соответствии с характером текущей тепловой нагрузки в соответствии с меняющимися текущими климатическими условиями с целью максимального или близкого к нему годового производства холода в соответствии с его расходованием на кондиционирование воздуха. В общем случае весь диапазон текущих тепловых нагрузок любой системы кондиционирования воздуха включает диапазон нестабильных нагрузок, связанных с предварительным охлаждением наружного воздуха со значительными колебаниями затрат холодопроизводительности в соответствии с текущими климатическими условиями, и сравнительно стабильную долю холодопроизводительности, расходуемой на снижение температуры воздуха от определенной пороговой температуры до конечной температуры на выходе. Совершенно очевидно, что стабильный диапазон тепловой нагрузки может быть обеспечен при работе обычного компрессора в режиме, близком к номинальному, тогда как предварительное охлаждение наружного воздуха со значительными колебаниями тепловой нагрузки требует регулирования холодопроизводительности путем применения компрессора с регулируемой скоростью. Таким образом, по характеру изменения текущих тепловых нагрузок любая система кондиционирования воздуха, то ли центральная система кондиционирования воздуха с его тепловлажностной обработкой в центральном кондиционере, то ли ее комбинация с местной рециркуляционной системой кондиционирования воздуха в помещениях, по сути, состоит из двух подсистем: предварительного охлаждения наружного воздуха и его дальнейшего охлаждения до установленной конечной температуры. Предложенный метод распределения проектного тепловой нагрузки в зависимости от характера текущих тепловых нагрузок весьма полезный для рационального проектирования систем центрального кондиционирования воздуха и их комбинированных версий с местной системой кондиционирования воздуха.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography