Dissertations / Theses on the topic 'UV index'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 26 dissertations / theses for your research on the topic 'UV index.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Badosa, i. Franch Jordi. "UV index measurement and model agreement: uncertainties and limitations." Doctoral thesis, Universitat de Girona, 2005. http://hdl.handle.net/10803/7905.
Full textL'índex ultraviolat (UVI), que ha estat adoptat internacionalment, va ser definit amb el propòsit d'informar al públic general sobre els riscos d'exposar el cos nu a la UVR i per tal d'enviar missatges preventius. L'UVI es va definir inicialment com el valor màxim diari. No obstant, el seu ús actual s'ha ampliat i té sentit referir-se a un valor instantani o a una evolució diària del valor d'UVI mesurat, modelitzat o predit. El valor concret d'UVI està afectat per la geometria Sol-Terra, els núvols, l'ozó, els aerosols, l'altitud i l'albedo superficial.
Les mesures d'UVI d'alta qualitat són essencials com a referència i per estudiar tendències a llarg termini; es necessiten també tècniques acurades de modelització per tal d'entendre els factors que afecten la UVR, per predir l'UVI i com a control de qualitat de les mesures. És d'esperar que les mesures més acurades d'UVI s'obtinguin amb espectroradiòmetres. No obstant, com que els costs d'aquests dispositius són elevats, és més habitual trobar dades d'UVI de radiòmetres eritemàtics (de fet, la majoria de les xarxes d'UVI estan equipades amb aquest tipus de sensors).
Els millors resultats en modelització s'obtenen amb models de transferència radiativa de dispersió múltiple quan es coneix bé la informació d'entrada. No obstant, habitualment no es coneix informació d'entrada, com per exemple les propietats òptiques dels aerosols, la qual cosa pot portar a importants incerteses en la modelització. Sovint, s'utilitzen models més simples per aplicacions com ara la predicció d'UVI o l'elaboració de mapes d'UVI, ja que aquests són més ràpids i requereixen menys paràmetres d'entrada.
Tenint en compte aquest marc de treball, l'objectiu general d'aquest estudi és analitzar l'acord al qual es pot arribar entre la mesura i la modelització d'UVI per condicions de cel sense núvols.
D'aquesta manera, en aquest estudi es presenten comparacions model-mesura per diferents tècniques de modelització, diferents opcions d'entrada i per mesures d'UVI tant de radiòmetres eritemàtics com d'espectroradiòmeters. Com a conclusió general, es pot afirmar que la comparació model-mesura és molt útil per detectar limitacions i estimar incerteses tant en les modelitzacions com en les mesures.
Pel que fa a la modelització, les principals limitacions que s'han trobat és la falta de coneixement de la informació d'aerosols considerada com a entrada dels models. També, s'han trobat importants diferències entre l'ozó mesurat des de satèl·lit i des de la superfície terrestre, la qual cosa pot portar a diferències importants en l'UVI modelitzat.
PTUV, una nova i simple parametrització pel càlcul ràpid d'UVI per condicions de cel serens, ha estat desenvolupada en base a càlculs de transferència radiativa. La parametrització mostra una bona execució tant respecte el model base com en comparació amb diverses mesures d'UVI. PTUV ha demostrat la seva utilitat per aplicacions particulars com ara l'estudi de l'evolució anual de l'UVI per un cert lloc (Girona) i la composició de mapes d'alta resolució de valors d'UVI típics per un territori concret (Catalunya).
En relació a les mesures, es constata que és molt important saber la resposta espectral dels radiòmetres eritemàtics per tal d'evitar grans incerteses a la mesura d'UVI. Aquest instruments, si estan ben caracteritzats, mostren una bona comparació amb els espectroradiòmetres d'alta qualitat en la mesura d'UVI. Les qüestions més importants respecte les mesures són la calibració i estabilitat a llarg termini. També, s'ha observat un efecte de temperatura en el PTFE, un material utilitzat en els difusors en alguns instruments, cosa que potencialment podria tenir implicacions importants en el camp experimental.
Finalment, i pel que fa a les comparacions model-mesura, el millor acord s'ha trobat quan es consideren mesures d'UVI d'espectroradiòmetres d'alta qualitat i s'usen models de transferència radiativa que consideren les millors dades disponibles pel que fa als paràmetres òptics d'ozó i aerosols i els seus canvis en el temps. D'aquesta manera, l'acord pot ser tan alt dins un 0.1º% en UVI, i típicament entre menys d'un 3%. Aquest acord es veu altament deteriorat si s'ignora la informació d'aerosols i depèn de manera important del valor d'albedo de dispersió simple dels aerosols. Altres dades d'entrada del model, com ara l'albedo superficial i els perfils d'ozó i temperatura introdueixen una incertesa menor en els resultats de modelització.
The increase in solar ultraviolet radiation (UVR) levels reaching the Earth surface during the last decades (mostly induced by the stratospheric ozone depletion), together with a detected increase in UVR-related diseases, has lead to a high volume of investigations about this band of the solar radiation and its effects on human beings.
The ultraviolet Index (UVI), which is currently internationally adopted, was defined in order to disseminate information to the public about the risks of exposing the naked body to UVR and to send preventive messages. UVI was initially defined as the maximum daily value. However, the current use of this index has been widened and nowadays it makes sense to refer to an instantaneous value or to the evolution of the measured, modelled, or predicted UVI during the day. The actual value of UVI is affected by the Sun-Earth geometry, clouds, ozone, aerosols, altitude and ground albedo.
High quality UVI measurements are essential as a reference and to study long-term trends; accurate modelling techniques are needed to understand the way factors affect UVR, to predict UVI, and as a quality control of the measurements. For the UVI measurement, best accuracy is expected with data from spectroradiometers. However, since the costs of these devices are expensive, data from erythemal radiometers are more commonly available (most UVI networks are equipped with this latter type of sensors). Best UVI modelling performance is found with multi-scattering radiative transfer models when the input information is well known. However, some relevant input information, such as the aerosol optical properties, is usually not available which can lead to large modelling uncertainties. More simple models are often used for applications such as UVI prediction or elaboration of UVI maps, as they are much faster and require less input parameters.
Considering this framework, the general objective of this work is to analyse the agreement that can be reached between modelled and measured UVI for cloudless conditions.
For this, model-measurement comparisons are presented for different modelling techniques, for several input options, and for UVI measured by both erythemal radiometers and spectroradiometers. As a general conclusion, it can be stated that the comparison of modelled vs. measured UVI is very useful to detect limitations and estimate uncertainties in both the modelling and measurements.
As far as modelling is concerned, the main limitations found are the lack of knowledge in the aerosol information considered as input. Also, important differences are found between the ozone column from satellite and from ground based measurements, which lead to important differences in the modelled UVI.
PTUV, a new simple parameterisation for fast UVI calculations for cloudless conditions, has been developed based on radiative transfer calculations. The parameterisation shows a good performance both with respect to the base model and to diverse UVI measurements. PTUV has demonstrated to be useful for particular applications such as to study the annual UVI variation at a particular site (Girona) and to build high resolution maps of typical UVI for a territory (Catalonia).
Regarding the measurements, it is found that the use of the actual spectral response of the erythemal radiometers is very important to avoid large uncertainties in the measured UVI. If well characterised, the erythemal radiometers compare reasonably well with high quality spectroradiometers when measuring UVI. Major issues with respect to the measurements are long term calibration accuracy and stability. Also, a temperature effect in PTFE, a material used as diffuser in some instruments, has been observed, which could have potentially important implications in the experimental field.
Finally, and concerning the model-measurement comparisons, the best agreement has been found when high quality spectroradiometric UVI measurements are considered and radiative transfer models are applied taking into account the best data available regarding aerosol and ozone optical parameters and their changes in time. In this case, the agreement can be as high as 0.1% in UVI, and typically less than 3%. This agreement deteriorates greatly if aerosols are ignored, and depends importantly on the aerosol single scattering albedo. Other data, such as ground albedo or the actual atmospheric temperature and ozone profiles, introduce lower uncertainty in the modelling results.
Estupin, Jeral Garcia. "The Direct Influence of Aerosols on UV Irradiance and the Development of a Synthetic Current UV Index." Diss., Georgia Institute of Technology, 2006. http://hdl.handle.net/1853/11602.
Full textPatistis, Andreas. "Contribution of each major wine phenolic family to the polyphenols index (IPT) evaluation." Master's thesis, ISA/UL, 2012. http://hdl.handle.net/10400.5/8615.
Full textWines are an important source of phenolic compounds. Red wines have a polyphenol content (especially tannins but also anthocyanins, flavonols, resveratrol and phenolic acids) considerably higher and different than whites. The phenolic content of wines is often described by two values that are called IPT and is representative of the total phenolic profile and anthocyanin index that is representative of the anthocyanins of a wine. The goal of this study is to try understanding how the different phenolic families contribute to the total polyphenolic index of the wine. For this reason representative compounds of some major phenolic families have been studied. The molecular absorbance was measured by a UV spectrophotometer at wavelength of 280 nm. From the result we calculated the polyphenolic index per milligram and the polyphenolic index of each compound used. This gave us an idea of the ‘’weight’’ that the different molecules have. Continuously combinations in pairs were made in order to try simulate better the wine environment. From the result obtained, we understood that total polyphenolic index per milligram for wine is a very complicated variable based both, in the ‘’weight’’ that the phenolic compounds have but also in the proportion that can be found in wine
Slavica, Malinović Milićević. "Monitoring nejonizujućeg zračenja, zagađujućih materija i toplotnih indeksa u regionu Vojvodine." Phd thesis, Univerzitet u Novom Sadu, Prirodno-matematički fakultet u Novom Sadu, 2012. https://www.cris.uns.ac.rs/record.jsf?recordId=83192&source=NDLTD&language=en.
Full textThis study analyzes UV radiation, heat indexes and air pollution in town in Vojvodina region. Objective of the thesis is to provide scientific facts about environmental quality in Vojvodina, as well as, to generate unique data base for the future research. The relationship between UV-B and global radiation has been studied and correlation equation for estimating UV-B from global radiation has been deduced. Equation was used for UV-B radiation calculation in eight towns in Vojvodina region during the period 1981-2008. This study also analyzes concentrations of five air pollutant in during the period 2001-2008, and heat index during the period 1992-2008. in seven towns in Vojvodina. The results from this study show growth UV-B radiation and heat index in all towns, and denote particulate maters as main air pollutants in Vojvodina towns.
Totová, Ivana. "Analýza rozkladu roztoků huminových kyselin diafragmovým výbojem." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2008. http://www.nusl.cz/ntk/nusl-216393.
Full textLehmann, Maria [Verfasser], Olaf [Akademischer Betreuer] Gefeller, and Olaf [Gutachter] Gefeller. "Untersuchungen zur Validität von Sonnenschutzempfehlungen für Tage mit niedrigen UV-Index-Werten / Maria Lehmann ; Gutachter: Olaf Gefeller ; Betreuer: Olaf Gefeller." Erlangen : Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 2019. http://d-nb.info/1201551560/34.
Full textKilic, Ilker. "Optical Characterization Of Silicon Based Hydrogenated Amorphous Thin Films By Uv-visible And Infrared Measurements." Master's thesis, METU, 2006. http://etd.lib.metu.edu.tr/upload/2/12607013/index.pdf.
Full textxCx:H) and hydrogenated amorphous silicon (a-Si:H) thin films have been deposited on various substrates by using plasma enhanced chemical vapour deposition (PECVD) technique. Transmission spectra of these films have been determined within UV-Visible region and the obtained data were analysed to find related physical constants such as
refractive indices, thicknesses, etc. Fourier transform infrared (FT-IR) spectrometry technique has been used to determine transmission &
reflection type spectra of these films. Obtained data were analysed to determine bond structures of the films. E®
ects of relative concentration of ethylene (C2H4) gas on thin film bond structure and on optical constants have been questioned.
Wang, M. (Meng). "Polymer integrated Young interferometers for label-free biosensing applications." Doctoral thesis, Oulun yliopisto, 2012. http://urn.fi/urn:isbn:9789514299643.
Full textTiivistelmä Integroidulla optiikalla toteutetut anturit mahdollistavat biomolekulaarisen vuorovaikutuksen tutkimisen käyttäen herkkiä moniparametrisia ja merkkiaineettomia menetelmiä. Näiden bioantureiden valmistukseen käytetään tavallisesti CMOS-teknologian piiristä tuttuja epäorgaanisia puolijohteita ja eristemateriaaleja. Viime aikoina on kuitenkin polymeeristen materiaalien käyttöä integroidussa optiikassa tutkittu merkittävästi johtuen polymeerien hyvistä optisista ominaisuuksista, monipuolisesta työstettävyydestä ja edullisista kustannuksista. Tämän työn tarkoituksena on kehittää edullisia, kertakäyttöisiä, pääasiallisesti polymeerisistä materiaaleista valmistettuja bioantureita, jotka vastaavat suorituskyvyltään epäorgaanisista materiaaleista valmistettuja integroidun optiikan antureita. Tässä työssä kehitetyt polymeeriset integroidun optiikan bioanturit perustuvat Youngin interferometriin mahdollistaen ympäristökohinan kompensoinnin ja ne tuottavat pintavuorovaikutusten tutkimiseen jaksoittaisen interferenssikuvion. Työssä hyödynnettiin kolmea erilaista valokanavarakennetta huomioiden niiden käytön helppous, valmistuksen yksinkertaisuus ja mittausherkkyys. Yksi kehitetyistä polymeerisistä bioantureista koostui päällekkäisistä kerrostetuista polymeerikerroksista. Toisen tutkitun rakenteen toiminta puolestaan perustui käänteiseen harjannevalokanavaan. Mittausherkkyyttä parannettiin pinnoittamalla polymeerirakenne Ta2O5-pinnoitteella. Näin muodostui kerrostettu komposiittivalokanava, joka oli tässä työssä tutkittu kolmas sensorirakenne. Itse bioanturien lisäksi kehitettiin myös valmistusprosessi, jossa hyödynnettiin UV-painatusta ja nestefaasipinnoitusta. Tässä työssä havaittiin lisäksi, että kehitetty yksinkertainen valmistusmenetelmä on paitsi toimiva, myös mahdollisesti siirrettävissä rullalta rullalle valmistus- ja tuotantoteknologiaan. Kehitettyjen anturien kalibrointi suoritettiin homogeenisella taitekerroinmittauksella käyttäen liuoksia, jotka valmistettiin glukoosista ja deionisoidusta vedestä. Kehitettyjen anturien soveltuvuus spesifien molekyylien tunnistamista varten todennettiin tutkimalla vasta-aineiden ja antigeenien sitoutumisreaktioita ja vuorovaikutusta C-reaktiivisella proteiinilla ja sen konjugaateilla. Lisäksi työssä tutkittiin veden absorption vaikutusta mittauksen stabiilisuuteen. Tutkimuksessa suoritettiin vertailu kehitettyjen anturien ja niiden ominaisuuksien välillä kiinnittäen huomiota mittausherkkyyteen, stabiilisuuteen, määritys- ja toteamisrajoihin ja muihin anturien valmistukseen sekä käyttöön liittyviin keskeisiin piirteisiin. Tulokset osoittavat, että Ta2O5-pinnoitetun polymeerivalokanavan mittausherkkyys oli suurin vertailluista rakenteista. Homogeenisessä taitekerroinmittauksessa saavutettu määritys- ja toteamisraja oli 9×10-7 taitekerroinyksikköä (RIU). Pintamassatiheysmittauksessa saavuttu tulos oli 270 fg/mm2
Izarra, Grégoire de. "Diagnostic des zones périphériques d’arcs électriques et des décharges hors-équilibre." Thesis, Orléans, 2013. http://www.theses.fr/2013ORLE2025/document.
Full textUntil recently, most of electrical arcs applications were dealing with the properties of the centre of the plasma column, a large number of works was then done to develop diagnostic techniques dedicated to those area where the mean temperature is about 10000 K. With the emergence of plasma chemistery, the diagnostic of arc’s peripheral areas and un-equilibrium discharges become a goal of prime importance. Classical diagnostic techniques are not adapted to those objects where the maximum temperature is around 8000 K; the principal aim of this work was to develop and check diagnostic techniques. Two inovating techniques based on refractive index, the quantitative shadowgraphy and the moiré deflectometry were studied extensively and checked on a laminar plasma jet, a perfect model of arc’s peripheral area. To probe unequilibrium discharge, the use of UV OH spectrum was considered. At this occasion, a spectrum simulation software was written. The study of synthetic spectra lead to the creation of simple measurement methods of rotationnal and vibrationnal OH temperature for a large range of resolution. Those methods was checked on a low power electric discharge. It can be shown that result from molecular spectroscopy are close to those obtained by simulation
Zamzow, Jill P. "The physiological ecology of UV-absorbing compounds from the mucus of marine fishes." Thesis, University of Hawaii at Manoa, 2003. http://proquest.umi.com/pqdweb?index=0&did=764803761&SrchMode=1&sid=2&Fmt=2&VInst=PROD&VType=PQD&RQT=309&VName=PQD&TS=1233342067&clientId=23440.
Full textHoráková, Hana. "Analýza hlavních sacharidů vína." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2009. http://www.nusl.cz/ntk/nusl-216520.
Full textSousa, Eldina Castro. "InvestigaÃÃo do potencial biotecnolÃgico do bagaÃo de uva (vitis vinÃfera l.) variedade benitaka, cultivada no municÃpio de SÃo JoÃo do PiauÃ, PI." Universidade Federal do CearÃ, 2014. http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=12103.
Full textFundaÃÃo de Amparo a Pesquisa do Estado do PiauÃ
Objetivo: Investigar o potencial biotecnolÃgico do bagaÃo de uva, variedade Benitaka, cultivada no municÃpio de SÃo JoÃo do PiauÃ, PiauÃ, por meio de metodologias analÃticas cientificamente reconhecidas, buscando reconhecer os principais grupos de metabÃlitos responsÃveis por atividade antioxidante. Metodologia: As uvas (Vitis vinifera L.), variedade Benitaka, foram resultantes da safra 2011/2012 e coletadas no Polo de Viticultura do Assentamento Marrecas, no MunicÃpio de SÃo JoÃo do PiauÃ/PI e posteriormente higienizadas, prensadas em despolpadeira para separaÃÃo do bagaÃo, o qual foi submetido à desidrataÃÃo, trituraÃÃo, peneiramento e formaÃÃo do bagaÃo de uva em pÃ. A partir do bagaÃo de uva em pà foram realizadas anÃlises da composiÃÃo centesimal, conteÃdo de minerais, fibra dietÃtica total, solÃvel e insolÃvel, determinaÃÃo de Vitamina C, conteÃdo de antocianinas, perfil de Ãcidos graxos e investigaÃÃo de sua qualidade microbiolÃgica. Foram tambÃm elaborados extratos a partir de diferentes solventes, os quais foram analisados quanto à toxicidade frente à Artemia salina sp., conteÃdo de fenÃlicos totais, flavonÃides totais e taninos totais; atividade antioxidante in vitro pelos mÃtodos de DPPHâ e autooxidaÃÃo do sistema β-caroteno/Ãcido linoleico; estabilidade oxidativa em Ãleo de soja e identificaÃÃo e quantificaÃÃo de polifenÃis por HPLC-UV. Os resultados foram expressos como mÃdia e desvio padrÃo (n=3) e utilizou-se o programa estatÃstico SAS para AnÃlise de VariÃncia e Teste de Tukey. Adotou-se o nÃvel de significÃncia de 5% (p<0,05). Resultados: Os resultados mostraram que no bagaÃo de uva em pà a quantidade de fibra dietÃtica total (46,17g/100g) se destacou quantitativamente em relaÃÃo aos carboidratos (29,2g/100g), proteÃnas (8,49g/100g) e lipÃdeos (8,16g/100g). O valor energÃtico total encontrado foi de 224Kcal/100g. A fraÃÃo fibra insolÃvel (79%) foi superior à fraÃÃo solÃvel (21%). O conteÃdo de Vitamina C foi de 26,25mg de Ãcido ascÃrbico/100g e de antocianinas, 131mg/100g. Os minerais ferro (18,08mg/100g), potÃssio (1,40mg/100g), zinco (0,98mg/100g), manganÃs (0,82mg/100g) e cÃlcio (0,44mg/100g) estavam presentes em maiores concentraÃÃes. A fraÃÃo lipÃdica foi composta principalmente por Ãcido linoleico (89,61%) e o teor de PUFA (89,61%) >MUFA (21,37%) >SFA (18,46%). O rendimento dos extratos variou de 6,85% a 45,5%, dependendo do solvente de extraÃÃo, sendo que o menor rendimento foi observado no extrato acetÃnico e o maior no extrato metanÃlico. O conteÃdo de fenÃlicos totais, flavonoides totais e taninos totais variaram em funÃÃo do solvente de extraÃÃo. Os extratos etanÃlico e acetÃnico conseguiram estabilizar o radical DPPHâ de forma eficiente, com valores de EC50 de 0,31 Âg/mL e 0,39 Âg/mL, os quais nÃo diferiram estatisticamente dos padrÃes quercetina (0,22 Âg/mL) e BHT (0,11 Âg/mL). Em relaÃÃo à avaliaÃÃo da atividade antioxidante pelo mÃtodo de autooxidaÃÃo do sistema β-caroteno/Ãcido linolÃico, os extratos agiram de forma similar ao antioxidante sintÃtico BHT, com mÃdias de EC50 de 0.34 Âg/mL a 0.36 Âg/mL. O extrato etanÃlico aumentou a vida de prateleira do Ãleo de soja de forma similar ao BHT. O composto fenÃlico presente em maior concentraÃÃo foi isoquercitrina (12,94 mg/100g), seguido de rutina (7,54 mg/100g), quercetina (5,4 mg/100g) e resveratrol (2,5 mg/100g). ConclusÃo: Os resultados mostraram que o bagaÃo de uva representa uma fonte potencialmente importante de nutrientes e compostos fenÃlicos; alÃm de elevado potencial antioxidante, o que contribui para o seu elevado valor como um subproduto de frutos, com possibilidades de comercializaÃÃo como antioxidante natural.
Schardosin, Janaina. "Caracterização da matéria orgânica humificada (ácido húmico) de solo por técnicas espectroscópicas, análise térmica e microscopia eletrônica." Universidade Estadual de Ponta Grossa, 2018. http://tede2.uepg.br/jspui/handle/prefix/2524.
Full textMade available in DSpace on 2018-06-05T14:40:04Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Schardosin, Janaina.pdf: 3840457 bytes, checksum: ffe3148238384650d2997e09aff27ed0 (MD5) Previous issue date: 2018-04-09
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
O processo de humificação, conversão de resíduos orgânicos em húmus, é um fator importante na compreensão da dinâmica da matéria orgânica. A sua quantificação, é fundamental para o estudo da evolução química dessa substância. O objetivo deste trabalho foi caracterizar as amostras de ácidos húmicos (AHs) e quantificar o grau de humificação do solo e das frações físicas (por tamanho de partículas). As análises de Espectroscopias de Fluorescência de Raios X por Dispersão de Comprimento de Onda, Fluorescência na região do Visível, Espectroscopia Vibracional na região de Infravermelho e de Absorção na região do Ultravioleta e Vísivel, Espectrocospia Raman, acompanhadas das técnicas de Análise Térmica, Microscopia Eletrônica de Varredura com Canhão Eletrônico por Efeito de Campo e Espalhamento Dinâmico da Luz foram utilizadas. A quantificação do grau de humificação mostrou que AHs extraídos da profundidade (10- 20 cm) possuem estruturas aromáticas mais condensadas. A fração de AH que apresentou maior grau de humificação foi a extraída do solo com a adição de calagem, o que demonstra uma influência do calcário na aceleração do processo de humificação. O estudo das frações granulométricas do solo, determinou, com espectroscopia de infravermelho, os atributos orgânicos que estão associados as frações do solo e, que a maioria dos minerais presentes nas frações granulométricas, foram identificados como sendo caulinita, haloisita, quartzo e gibbsita. Já para o estudo da humificação dos AHs extraídos das frações granulométricas, a quantificação do grau de humificação, do maior para o menor, é procedente da fração silte, seguidos da fração argila e, por fim, a fração areia.
The humification process, conversion of organic waste into humus, is an important factor to understand the organic matter dynamics. Its quantification is vital for the study of this substance chemical evolution. This study aimed at characterizing humic acid (HA) samples and quantify the degree of soil humification and physical fractions (particle size). The analysis of Spectroscopies of wavelenght dispersive X-ray fluorescence, visible fluorescence, vibrational infrared region, ultraviolet and visible light absorption and Raman along with the techniques of Thermal Analysis, scanning electron microscopy with field effect gun and dynamic light scattering were employed. The humification degree quantification revealed that the HA extracted from the 10-20cm depth presented more polycondensed structures. The HA fraction that presented the highest humification degree was extracted from the soil with the addition of liming, which demonstrates the limestone influence in the acceleration of the humification process. The study of the soil granulometric fractions determined, with infrared spectroscopy, the organic properties that are associated to soil fractions and that most of the minerals present in the granulometric fractions, were identified as kaolinite, halloysite, quartz and gibbsite.The study of the humification in the HA extracted from the granulometric fractions quantified the humification degree and revealed the highest values in the silt fraction followed by the clay fraction and, finally, the lowest values were found in the sand fraction.
Puttagunta, Rupesh Kumar. "Characterization and kinetic evaluation of UV system used to treat commercial kitchen exhaust emissions a thesis presented to the faculty of the Graduate School, Tennessee Technological University /." Click to access online, 2008. http://proquest.umi.com/pqdweb?index=0&did=1605147091&SrchMode=1&sid=2&Fmt=6&VInst=PROD&VType=PQD&RQT=309&VName=PQD&TS=1269016483&clientId=28564.
Full textMlčák, Petr. "IoT systém pro zahrádkáře." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2021. http://www.nusl.cz/ntk/nusl-442383.
Full textHSIEH, MENG-CHIN, and 謝孟錦. "The Characteristics of UV Index Distribution in Taiwan." Thesis, 2016. http://ndltd.ncl.edu.tw/handle/py26e8.
Full text大仁科技大學
環境管理研究所
104
The purpose of this study was to investigate the Temporal and Spatial characteristics of ultraviolet (UV) index in north, central, south, east regions, and offshore islands of Taiwan and further compare Taiwan’s UV readings with Australia. Results showed that Taiwan's UV readings are higher in summer and lower in winter. In summer, UV readings concentrate at the very high radiation level, and readings above the high level account more than 50%. In winter, UV readings concentrate at the moderate or low level, but readings at the extreme level may also occur in high mountain areas. Besides, regional distributions and variations of UV radiation levels are similar across Taiwan, where moderate readings account for the majority, followed by very high readings and high readings in similar ratios. The ratio of high readings is highest in central and south Taiwan and lowest in north Taiwan; the ratio of very high readings is higher in central, south, and east Taiwan and lower in north and offshore islands of Taiwan; in terms of extreme readings, east Taiwan has the highest ratio, followed by central and south Taiwan, while north Taiwan has the lowest. As to distribution of radiation levels in areas of high concern, the monitoring station in Pingtung shows high level > moderate > very high > extreme > low level in the area. The high level readings take 67% annually and 86.2%~97.4% from May to August. The monitoring station in Kenting showed very high > moderate > high > extreme = low level in the area. Readings above the high level account for 65.4% annually and 73.3%~96.7% from April to October. In high mountain areas, Tataka and Mt. Jade stations have respectively detected a UV index of 11 or higher in 84 and 118 days, even during winter times. The highest UV index ever recorded in Mt Ali is 8 and that in Sun Moon Lake is 12. Finally, comparison of UV index in Taiwan and Australia in the same time periods showed that Alice Springs has higher monthly average and annual average than Taiwan. In terms of annual average, the index in Australia is 1.45 times of the index in Taiwan.
Human, Sep. "Assessment of UV index using artificial neural networks." Thesis, 2002. http://hdl.handle.net/10321/1917.
Full text"UV index measurement and model agreement: uncertainties and limitations." Universitat de Girona, 2005. http://www.tesisenxarxa.net/TDX-0206106-125633/.
Full textChung, Li-Fan, and 鍾禮帆. "Fabrication and property analysis of high refractive index UV resins." Thesis, 2009. http://ndltd.ncl.edu.tw/handle/30882648261281171565.
Full text淡江大學
機械與機電工程學系碩士班
97
A UV curing acrylic resin /nano scaled meter zinc oxide hybrid films with tunable optical properties were prepared by means of the sol-gel synthesis method. The ZnO precursor solution which includes different weight ratios(30wt%、40wt%及50wt%) mixed with the UV curing acrylic resin through the way of sol-gel,and then this synthesis generates transparent hybrid films via the process of make a wet thin film by deposition on spotless glass substrate,ultraviolet curing and desorption treatment at different drying temperatures (250℃、275℃and 300℃). The approximately 40nm-80nm zinc oxide uniformly distributes over a matrix and FTIR analysis show no existence of chemical bodings between zinc oxide and UV curing acrylic resin。The refractive indices of these molecular hybrid films are much higher than that of UV curing acrylic resin e.g., at a ZnO loading of 30 wt % under at 300℃desorption treatment, the resulting molecular hybrid film exhibits a measured refractive index of 1.72 compared to that of 1.63.Additional, the cut-off wavelength of transmittance at ultraviolet wavelength range in the hybrid films shifted to the long wavelength side.
Tomanová, Helena. "Závislost hodnot UV indexu na vybraných parametrech." Master's thesis, 2021. http://www.nusl.cz/ntk/nusl-445942.
Full textRamsden, Samuel David. "Experimental and evolutionary analysis of the retinal mechanisms mediating UV polarization vision." Thesis, 2005. http://hdl.handle.net/1828/1883.
Full textWang, Po-Cheng, and 王博正. "The Study of Sulfur-containg High Refractive Index UV Curning Synthesis and Physical Properties Based on Dendrimer." Thesis, 2010. http://ndltd.ncl.edu.tw/handle/68fq38.
Full text國立臺北科技大學
有機高分子研究所
98
This work, we use dendrimer which has high branch and is a three-dimentional space structure, it has nighteen acrylate group. It reacts with different amount of Thiophenol, 4-Methylthiophenol, 2-Mercaptothiazoline, 2-Mercaptobenzothiazole to proceed the addition reaction for synthesizing the Sulfur-containg high refractive index UV curing oilgomer. To explore the effects of the structure on the refractive index,and then we can test the structure identification by FT-IR, HPLC and the physical properties by Refraction index, Rheometer, Pencil Hardness, Thermal Gravimetric Analysis (TGA), Doublebean Photocalorimeric Accessory(DPA). In the experimental results, the more moles of thiols branch of the dendrimer the higher RI index ,viscosity, and thermal cracking temperature of that. In these thiols,2-Mercaptobenzothiazole structure which enhance the refraction index is the largest. In UV curing Kinetic analysis, 4-Methylthiophenol system has the highest conversion and reaction rate.In the hardness test, 2-Mercaptothiazoline system has the highest hardness.
Chen, Bo-chan, and 陳柏彰. "Measurement of Refractive Index of A Roll-to-roll UV Embossed Film through A Blazed Phase Gating." Thesis, 2012. http://ndltd.ncl.edu.tw/handle/3gcuuv.
Full text逢甲大學
資訊電機工程碩士在職專班
100
Abstract: This paper reports an evaluation method of the refractive index of ultraviolet (UV) exposed resin by monitoring the diffraction pattern of a roll-to-roll imprinted blazed grating. The relationship among the diffraction efficiency, refractive index and shape of the grating is calculated using the commercial rigorous coupling wave analysis (RCWA) modeling software. The objective is to determine the refractive index to a precision of the order of 10-3 to insure the accuracy of the ray tracing simulation in the design of UV embossed structured films. Keyword : GSOLVER、Roll-to-Roll
Lin, Chia-Ying, and 林佳穎. "Preparation and characterization of TiO2 sol for UV-cured high-refractive-index organic-inorganic hybrid thin films." Thesis, 2011. http://ndltd.ncl.edu.tw/handle/97544395217381997896.
Full text淡江大學
化學工程與材料工程學系碩士班
99
In this study, UV-cured hybrid optical thin films were successfully prepared on PMMA substrates using TiO2 sols and acrylic monomers. TiO2 nanoparticles were synthesized via a sol-gel route at room temperature. Through the heat reflux process, the TiO2 nanoparticles became partial crystalline. The prepared TiO2 sols can provide operating control for the preparation of hybrid thin films by spin coating. Transparent high-refractive-index thin films were obtained with high TiO2 content. Photocatalytic ability of synthesized TiO2 nanoparticles was poor while some crystal structure existed. This may resulted from limited crystallinity of TiO2, and avoided a distinct degradation of organic moieties in the hybrids. TiO2 sols were characterized by DLS, TEM, XRD, and UV-Vis absorption, while TiO2 hybrid thin films were analyzed by UV-Vis absorption, FTIR, N&K, TGA, SEM, AFM, and contact angle. All hybrid thin films showed good adhesion to the PMMA substrate with refractive index falling over the range 1.66-1.82. These results suggested the potential application of present TiO2 hybrid films in optical devices, such as anti-reflective coatings.
Shaw, Conor Patrick. "The use of UV resonance Raman spectroscopy in the analysis of ionizing radiation-induced damage in DNA." Thesis, 2007. http://hdl.handle.net/1828/271.
Full textYao, Chih-Hsien, and 姚志賢. "The collimated characteristic improvement of fiber lenses for long-The collimated characteristic improvement of fiber lenses for long-distance application using arcing,gradient index and UV-curable methods." Thesis, 2006. http://ndltd.ncl.edu.tw/handle/29699929870498697547.
Full text建國科技大學
機電光系統研究所
94
In this thesis, the main purpose is how to analyze and make acing,gradient index and UV-curable fiber lens, and elucidates differences and restrictions of usages between these three kinds of fiber lenses. Lens will discharge due to the tilting arc during to make a arcing fiber lens. So now, this situation can be controlled by having the curvature radius range between 70 ~ 125μm ±2μm. This can be completed by cutting the gradient index fiber lens with precise measurements. The range of cutting length is 100 m ~ 10 mm. As the result of the 10m of distributing points limit, the margin of error will be ±12 m. The surface of UV-curable fiber lens can be handled through O2 plasma. So now, the radius curvature can be controlled within the range of 65 ~ 92μm and margin of error will be ±2μm. The arcing fiber lens will cause the optic axis to tilt at approximately 4.3 degrees, while the optic axis of the gradient index fiber lens tilt at approximately 0.5 degrees. The tilt of optic axis of the UV-curable fiber lens is much smaller than both the arcing fiber lens and the gradient index fiber lens. Therefore, the UV-curable fiber lens has higher product developing value with whole and simple design.