Dissertations / Theses on the topic 'TransLucid'

To see the other types of publications on this topic, follow the link: TransLucid.

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'TransLucid.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Franceschini, Marie Elisa. ""L'esthétique du translucide" chez José Sanchis Sinisterra." Toulouse 2, 2009. http://www.theses.fr/2009TOU20061.

Full text
Abstract:
Pour son théâtre, José Sanchis Sinisterra revendique depuis le début des années 90 « l’esthétique du translucide », le translucide étant ce qui laisse passer la lumière sans laisser voir clairement les choses. Après une évocation des prémices du « translucide » dans le parcours du dramaturge, la thèse propose une définition des fondements théoriques de cette esthétique. Les nouvelles sciences du XXème siècle (quantique, chaos, systémique) ont, par leurs répercussions philosophiques, modifié les modes de représentation du réel et inspiré les artistes. Chez Sinisterra, l’influence se ressent au niveau thématique, métaphorique et esthétique. Les mécanismes qui rompent avec la transparence sont la fragmentation (discontinuité, incomplétude), et le flou qui brouille les limites, relativise les dichotomies, créant l’ambiguïté et la complexité. L’analyse montre comment ces mécanismes s’appliquent à la dramaturgie : fable, temps, espace, sons, personnages, langage. À côté des sources d’opacité, l’étude met en évidence la part doublement lumineuse du translucide. La première lumière, celle de l’auteur, est certes partielle, mais aussi multiple, scintillante et poétique. La deuxième, celle du récepteur, éclaire l’œuvre par un déchiffrage constant, et des interrogations perpétuelles. Le lecteur/spectateur devient ainsi co-créateur d’un sens multiple. Ce que suggère finalement cette esthétique, c’est la translucidité du rapport à soi, à l’autre et au monde postmoderne, mais aussi la translucidité du rapport à l’œuvre d’art. En pointant les sources d’opacité, ce théâtre met le récepteur au défi de conjuguer liberté et responsabilité pour que son trajet reste lumineux malgré le flou
Since the early 90s, José Sanchis Sinisterra has held his theory of “the aesthetic of the translucent” as the mainstay of his theatre. The translucent is what allows light to pass through but prevents perception of distinct images. After an introduction on the emergence of the “translucent” in the career of the playwright, this thesis will provide a definition of the theoretical principles of this aesthetic. The new sciences which emerged in the 20th century (quantum mechanics, chaos theory…) have changed the modes of representation of reality and become a source of inspiration for artists. In Sinisterra’s drama, this influence is at work thematically but also aesthetically. The mechanisms which break away from transparency are that of fragmentation and vagueness which blurs limits, questions dichotomies, thus breeding ambiguity and complexity. This study shows how these mechanisms can be applied to drama: fable, time, space, sound, characters, language. As a counterpoint to these sources of opacity, this work argues that the translucent sheds two types of lights. The first light generated by the author is incomplete but also protean, sparkling and poetical. The second cast by the receiver sheds light onto the work by constantly decoding it. Therefore, the receiver becomes the co-author of a variety of meanings. Eventually, what this aesthetic underpins is the translucent nature of the relationship with Oneself, with the Other and with the Postmodern world, but also with the work of art. By focusing on the sources of opacity, this type of theatre challenges the spectator to combine freedom and responsibility so that his vision remains clear in spite of the haziness
APA, Harvard, Vancouver, ISO, and other styles
2

Benmounah, Nadir. "Rendu temps-réel d'objets translucides." Limoges, 2009. https://aurore.unilim.fr/theses/nxfile/default/e76da47c-c965-4fbf-bdb6-7a2831e78925/blobholder:0/2009LIMO4031.pdf.

Full text
Abstract:
La reproduction du réel dispose d'un intérêt croissant en synthèse d'images. La translucidité est un phénomène qui ajoute aux images reproduites, un réalisme certain. La simulation de l'absorption de la lumière par la matière a su profiter de l'abondance de la littérature scientifique, ainsi que des performances actuelles des cartes graphiques, afin de s'imposer comme une nouvelle branche de recherche en synthèse d'images. Dans cette thèse, nous décrivons deux méthodes de rendu temps-réel d'objets translucides. La première méthode autorise la déformation en temps-réel de ces objets, à l'aide d'atlas de textures flexibles. Dans la seconde, nous nous sommes intéressés à la porcelaine. Ce matériau doit sa notoriété à sa translucidité, et à sa blancheur. Le rendu de la porcelaine est effectué après une phase d'acquisition de ses propriétés optiques et l'introduction du modèle de Kubleka-Munk
The reproduction of nature in computer-added applications knows a significant revolution. Translucidity enhances the realism virtual images. Light absorption simulation has taken profits of the abundant scientific literature in physics and optics, and of the last advancements in graphics cards technologies, to establish itself as a new branch in image synthesis research. In the scope of this thesis, we describe two different methods in real-time rendering of translucent objects. The first method allows real-time deformation of these objects, by means of flexible texture atlases. In the second, we focused on porcelain. This material is famous for its translucidity and its whiteness. Porcelain rendering is achieved after the acquisition of its optical properties and the use of Kubelka-Munk model
APA, Harvard, Vancouver, ISO, and other styles
3

Sing, Alain Joseph F. "Contribution à l'étude d'émulsions translucides." Pau, 1997. http://www.theses.fr/1997PAUU3011.

Full text
Abstract:
Dans les annees soixante, k. Shinoda fut le premier a explorer l'influence de la temperature sur l'emulsification. Il etablit qu'un melange eau/huile/tensioactif non ionique, qui donne une emulsion d'huile dans l'eau a temperature ambiante, s'inverse en une emulsion d'eau dans l'huile lorsque la temperature depasse une temperature seuil, appelee temperature d'inversion de phase. Il montra ensuite qu'une agitation moderee, pratiquee 2 a 4c au-dessous de cette temperature permet d'obtenir une emulsion d'huile dans l'eau composee de gouttelettes aussi petites que celles formees sous agitation violente a temperature ambiante, a condition toutefois que le retour a la temperature ambiante soit tres rapide pour limiter le grossissement des gouttelettes. Notre contribution est une amelioration raisonnee du travail de k. Shinoda. Dans un premier temps, grace a des mesures de conductivite electrique, nous avons etudie les structures que presentent successivement les melanges eau/huile/tensioactif non ionique en fonction de la temperature. Autour de la temperature d'inversion de phase, nous avons mis en evidence une plage de temperatures dans laquelle cette structure est bicontinue. Dans cette plage les tensions interfaciales sont suffisamment basses pour permettre la formation d'une aire interfaciale eau/huile consequente. Nous montrons qu'il est possible d'optimiser l'etendue de cette aire en ajustant la concentration du tensioactif et la duree de sejour du systeme a la temperature choisie. Nous verifions ensuite que le refroidissement du melange bicontinu, sous tres faible agitation pour cause d'homogeneisation, provoque la fragmentation de l'huile en de tres fines gouttelettes a la sortie de la zone bicontinue. A partir de mesures de diffusion quasi-elastique de la lumiere, nous trouvons que les gouttelettes formees ont des diametres compris entre 10 nm et 70 nm. Cette extreme petitesse est responsable de la translucidite des emulsions et de l'amelioration notable de leur stabilite par rapport aux emulsions de k. Shinoda. Cette amelioration permet un retour a vitesse moderee a la temperature ambiante sans nuire a la petitesse des gouttelettes. Les emulsions translucides sont facilement diluables dans des solutions aqueuses. Les mesures de diffusion quasi-elastique de la lumiere revelent que le potentiel d'interaction de leurs gouttelettes est un potentiel repulsif de type spheres dures. Nous trouvons par ailleurs que leur lente deterioration est amorcee par la coalescence dynamique des gouttelettes qui sont assez petites pour etre sensibles a l'agitation thermique. Les taux de coalescence, mesures a partir du suivi de l'augmentation de la taille des gouttelettes, sont d'autant plus petits que l'encombrement sterique des molecules tensioactives est grand. Les emulsions translucides se rangent dans la categorie des systemes que de plus en plus de specialistes appellent miniemulsions. Elles ont un bel avenir tant du point de vue pratique, par l'amelioration de leur stabilite par rapport a celle des emulsions ordinaires, que du point de vue fondamental, pour l'etude de la coalescence de petits objets sensibles a l'agitation thermique.
APA, Harvard, Vancouver, ISO, and other styles
4

KOPP, MATTHIEU. "Physico-chimie des nuages moleculaires translucides." Paris 11, 1996. http://www.theses.fr/1996PA112498.

Full text
Abstract:
Ce travail s'inscrit dans le cadre de l'effort de comprehension des processus physico-chimiques gouvernant l'evolution des nuages interstellaires translucides et des regions dominees par les photons ultraviolets. L'objectif est double: presenter de nouvelles observations de telles regions, mais surtout fournir aux observateurs de nouveaux outils d'analyse de leurs donnees sous la forme d'un modele auto-coherent de nuage. Le modele developpe dans cette these apporte des ameliorations essentielles par rapport aux modeles de nuages interstellaires existants en traitant de maniere detaillee et en geometrie spherique, le transfert du rayonnement uv et son couplage avec la chimie du milieu. La diffusion du rayonnement par les grains est en particulier prise en compte de maniere coherente. Je presente des resultats montrant l'impact des ameliorations apportees par ce travail. Je montre notamment que la solution a l'equilibre stationnaire est tres sensible aux parametres geometriques, et donc a la structure tridimensionnelle des nuages impossible a apprehender par les seules observations. Je presente pour finir des observations millimetriques et sub-millimetriques de la nebuleuse b33 (tete de cheval) qui s'avere etre un laboratoire remarquable pour tester ces modeles
APA, Harvard, Vancouver, ISO, and other styles
5

Souza, Filho Agostinho Linhares. "Projeto de redes translucidas de longa distancia." [s.n.], 2003. http://repositorio.unicamp.br/jspui/handle/REPOSIP/258873.

Full text
Abstract:
Orientador: Helio Waldman
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação
Made available in DSpace on 2018-08-03T17:26:49Z (GMT). No. of bitstreams: 1 SouzaFilho_AgostinhoLinhares_M.pdf: 3733512 bytes, checksum: 6a9077f7c87ccb20051cd56683388195 (MD5) Previous issue date: 2003
Mestrado
APA, Harvard, Vancouver, ISO, and other styles
6

Bouté, Gérard. "Transparent, translucide, opaque : place du regard dans l'ordre pictural société, imaginaire." Paris 8, 1994. http://www.theses.fr/1994PA080942.

Full text
Abstract:
Quelle est la natrue du regard que posent sur le tableau le peintre et le spectateur? quelles sont les qualites propres a la peinture susceptibles d'en faire une oeuvre d'art? cet essai tente d'elaborer cette problematique et d'y repondre, en formulant l'hypothese qu'un desir inconscient, faconne par l'imaginaire social, determine le regard, conditionne la qualite de l'espace pictural et lui confere son pouvoir specifique. Dans une premiere partie, il s'agit de questionner la theorie lacanienne du regard, puis de conceptualiser trois instances : transparent, translucide, opaque comme ordonnatrices du champ pictural. Quels sont leurs roles? les categories du regard sont ensuite differenciees, analysees et les acteurs plastiques propres a l'oeuvre definis. Ces outils conceptuels sont mis a l'epreuve dans une seconde partie. Selon cette these, le translucide - "voile" ne a la renaissance - est l'une des instances qui symbolisent la loi dans l7espace pictural. Sans la reconnaissance de cette loi par l'artiste, sans le desir aussi de la subvertir, la peinture echappe a son pouvoir propre. Il semblerait que le translucide ait commence a disparaitre avec l'impressionnisme et qu'il ait completement cesse d'exister dans une partie de l'art contemporain. Quelles en sont les consequences? la peinture serait-elle conduite ainsi hors de l'art, non plus comme plus comme satisfaction substitutive d'un desir impossible a satisfaire dans la realite mais comme la satisfaction d'un besoin?
What nature of look do the artist and the beholder cast upon the picture? what are the qualities inherent in a painting that make a work of art? this essay attempts to analyse these questions and offer some answers based on the theory that an inconscious desire, shaped by social imaginary dimensions, predetermines the look, conditions the quality of the pictural environment and conveys its specific power. The first part of the essay questions lacan's theory of the look, then introduces three governing media - transparent, translucent, opaque - as controllers of the pictural framework. What roles do they play? the families of look are then differentiated and analysed, and the plastic ators specific to the work of art are defined. These conceptual tools are tested in the second part of the essay. According to this thesis, translucent - the "veil" created by the renaissance - is one of the governing media which symbolise the law within the pictural environment. If the artist does not recognise this law, if he doe not also try to subvert it, the painting will escape from his control. It would seem that the translucent starded to disappear with the immpressionist and that it has completely. Ceased to exist in a part of contemporary art
APA, Harvard, Vancouver, ISO, and other styles
7

Goveia, Jane Cleide. ""Estudo colorimétrico da translucidez de materiais restauradores odontológicos"." Universidade de São Paulo, 2005. http://www.teses.usp.br/teses/disponiveis/23/23134/tde-06062005-163034/.

Full text
Abstract:
Quando um dente anterior é restaurado toda uma técnica de proteção ao tecido remanescente e a recuperação funcional do elemento dental podem ser comprometidas se a escolha da cor do material restaurador empregado não for adequada. A familiaridade com as teorias da cor e da interação da luz com a matéria pode ajudar na tarefa de escolha da tonalidade do material restaurador. O desafio na busca de um material restaurador ideal na sua função estética sempre foi obter a translucidez própria do esmalte dental. Contudo, essa translucidez faz com que o material restaurador sofra influência da cor de fundo, que pode ser da cor do material de proteção, ou mais normalmente da cor da dentina. No que tange as atividades de restauração estética odontológico, através deste trabalho foi possível concluir que: 1) A colorimetria pode ser um importante meio na seleção e na comunicação de tonalidades de materiais restauradores; 2) Os resultados obtidos confirmam que a cor de fundo exerce grande influência sobre a cor do resultado final da restauração; e 3) Os guias de tonalidade devem ser reformulados de tal forma que levem em consideração a espessura do material restaurador e a cor de fundo.
When an anterior tooth is restorated, the whole remaining tissue protection technique and functional recuperation of the dental element can be compromised if the choice of the color of the restorative material is not adequate. The familiarity with the color and light interaction with matter theories may help with the task of choosing the restorative material shade. The challenge in searching for an ideal restorative material in its esthetic function was always obtaining the proper translucency of dental enamel. However, this translucency makes the restorative material suffer an influence of the background color, which can be the protection material color or, more commonly, the dentine color. Concerning the odontologic esthetic restorative activities, it was possible to conclude from this work that: 1) Colorimetry can be an important way for the selection and communication of the restorative material shades; 2) The results show that the background color has a large influence on the final color of the restoration; and 3) The shade guides must be reformulated so that it take into consideration the thickness of the restorative material and background color.
APA, Harvard, Vancouver, ISO, and other styles
8

Prado, Pedro Henrique Condé Oliveira. "Cinética de degradação de zircônias odontológicas com alta translucidez." Universidade Estadual Paulista (UNESP), 2018. http://hdl.handle.net/11449/152667.

Full text
Abstract:
Submitted by Pedro Henrique Conde Oliveira Prado (pedrohcop@hotmail.com) on 2018-01-30T04:57:56Z No. of bitstreams: 1 PRADO_phco_me_SJC.pdf: 11588382 bytes, checksum: b5aad78aae05251739002f306dd6e1be (MD5)
Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-02-05T12:03:17Z (GMT) No. of bitstreams: 1 prado_phco_me_sjc.pdf: 11588382 bytes, checksum: b5aad78aae05251739002f306dd6e1be (MD5)
Made available in DSpace on 2018-02-05T12:03:17Z (GMT). No. of bitstreams: 1 prado_phco_me_sjc.pdf: 11588382 bytes, checksum: b5aad78aae05251739002f306dd6e1be (MD5) Previous issue date: 2018-01-12
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Com o avanço da ciência e processamento de materiais, a zircônia odontológica deixou de ser um material opaco para apresentar certa translucidez, possibilitando a confecção de peças ultrafinas. Sabe-se que a água em contato com a superfície das zircônias convencionais acarreta na transformação de fase T-M e subsequente decréscimo de resistência, mas esses efeitos nas zircônias translúcidas ainda não foram explorados. Para avaliar, mapear e caracterizar os efeitos da cinética de envelhecimento acelerado em zircônias de alta translucidez, foram cortados 39 blocos de Y-TZP (VITA YZ, VITA HT, InCoris TZI) para cada zircônia comercial, onde posteriormente foram sinterizados (1530 ºC, 2h) e atribuídos a 13 grupos com 3 amostras cada: Um controle e 12 envelhecidos hidrotermicamente a 134 ºC com pressão constante de 2 bars por 6, 10, 14, 18, 22, 26, 30, 40, 60, 80, 100 e 140 horas. A análise em DRX foi utilizada para quantificar a transformação de fase da zircônia (tetragonal-monoclínica) em diferentes profundidades do material ao se trocar o ânodo do tubo irradiador (Cr, Co e Cu). Uma curva cinética de envelhecimento foi feita para cada profundidade para as 3 zircônias comerciais. Para avaliar os efeitos do envelhecimento hidrotermal nas propriedades mecânicas, 270 discos de Y-TZP foram cortados, 90 para cada tipo, sinterizados e atribuídos a 3 grupos: C-Controle; E1- envelhecido até 26h e E2- envelhecido até 140 horas. Os discos foram testados em uma máquina de teste universal (EMIC). A microestrutura dos discos foi avaliada sob MEV. As curvas de cinética do envelhecimento funcionaram de forma semelhante para todas as zircônias utilizadas neste estudo, caracterizadas por uma rápida transformação de fase T-M em função do tempo e estabilização de um platô após uma média de 26 horas. As camadas superficiais apresentam concentrações mais elevadas de fase monoclínica à medida em que essa concentração diminuiu em camadas mais profundas. O envelhecimento hidrotermal através de 140h diminuiu a tenacidade da cerâmica VITA YZ em 17% (681,78 ± 121,18) quando comparado ao seu grupo controle (841,69 ± 56,01), enquanto que as zircônias de alta translucidez não mostraram diferenças estatísticas de resistência flexural após o envelhecimento. O envelhecimento hidrotermal induz a transformação da fase martensítica de fora para dentro do material e não afeta as propriedades mecânicas das cerâmicas VITA HT e INCORIS TZI, enquanto diminui a dureza do material da zircônia VITA YZ.
To evaluate, map and characterize the effects of the accelerated aging kinetics of high translucency zirconias, this study was split into 2 parts: One part evaluating the superficial changes after in vitro hydrothermal aging and the second part aiming the effects of this aging on the mechanical properties of those ceramics. 117 Y-TZP (VITA YZ, VITA HT, InCoris TZI) blocks were cut, 39 for each commercial zirconia, sintered (1530 ºC, 2h) and assigned to 13 groups with 3 samples each: One being a control, aging-free group, and 12 groups that were prematurely aged hydrothermally at 134 ºC and constant pressure of 2 bars through 6, 10, 14, 18, 22, 26, 30, 40, 60, 80, 100 and 140 hours. XRD was used to quantify the amount of zirconia phase transformation (tetragonalmonoclinic) on different depths of the material by swapping the anode tube (Cr, Co, and Cu). An aging kinetic curve was made for each depth for the 3 commercial zirconias. To evaluate the effects of the hydrothermal aging on the mechanical properties, Y-TZP blocks were rounded to a cilindrical shape. 270 discs were cut, 90 for each kind, sintered as mentioned above and assigned to 3 groups: C-Control; E1- Aged through 26h and E2- Aged through 140h. Disks were then tested in a universal testing machine (EMIC) under a load of 1000 kg till fracture of the specimen and the surface was evaluated under SEM. The aging kinetics curves work similarly for all the YTZP used in this study, characterized by phase transformation ascendant and plateau stabilization as far as the aging goes. Superficial layers present higher concentrations of monoclinic phase as it decreases in deeper layers. Hydrothermal aging through 140h decreased VITA YZ toughness by 17% (681,78 ± 121,18) when compared with its control group (841,69 ± 56,01), while high translucency zirconias didn't show any statistical differences after aging.Hydrothermal aging does induce martensitic phase transformation from the outside-to-inside the material and doesn't affect the mechanical properties of VITA HT and INCORIS TZI ceramics, while it decreased the material toughness of VITA YZ zirconia.
FAPESP: 16/03688-1
APA, Harvard, Vancouver, ISO, and other styles
9

Al, Zahr Sawsan. "Planification de réseaux WDM translucides avec qualité de transmission garantie." Phd thesis, Télécom ParisTech, 2007. http://pastel.archives-ouvertes.fr/pastel-00004014.

Full text
Abstract:
De nombreuses études ont été réalisées autour du problème du routage et de l'affectation de longueur d'onde dans les réseaux WDM transparents. La majorité de ces études néglige les effets physiques liés à la transmission sur fibre. En effet, le signal optique subit le long de son trajet plusieurs dégradations, à savoir les effets linéaires et les effets non-linéaires. Dans les réseaux WDM opaques, la qualité du signal optique est considérée comme toujours satisfaisante car le signal est régénéré à chaque nœud du réseau. Cependant, cette faculté de régénération coûte très cher à l'opérateur et rigidifie totalement la capacité du réseau. Les réseaux WDM translucides présentent une nouvelle alternative. Ils offrent la possibilité de régénérer le signal à un nœud intermédiaire dès que la qualité de celui-ci devient inadmissible par rapport aux contraintes imposées par l'opérateur. Dans cette thèse, on s'intéresse au problème de la planification des réseaux WDM translucides de façon à garantir une certaine qualité de transmission. Nous proposons un nouvel outil de dimensionnement, LERP (Lightpath Establishment and Regenerator Placement), dont l'objectif est de fournir une solution permettant d'optimiser à la fois l'utilisation des ressources du réseau et la qualité de transmission sur l'ensemble de connexions établies. Le facteur Q permettant d'évaluer la qualité du signal est calculé au moyen d'un outil que nous avons également développé : BER-Predictor. Cet outil tient compte de quatre dégradations liées à la transmission sur fibre, à savoir la dispersion chromatique, la dispersion modale de polarisation, la phase non-linéaire et l'émission spontanée amplifiée.
APA, Harvard, Vancouver, ISO, and other styles
10

Almeida, Adriano Gondim. "Translucidez e luminosidade de compósitos para esmalte em diferentes espessuras." reponame:Repositório Institucional da UFSC, 2014. https://repositorio.ufsc.br/xmlui/handle/123456789/128628.

Full text
Abstract:
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2014
Made available in DSpace on 2015-02-05T20:11:07Z (GMT). No. of bitstreams: 1 329193.pdf: 1313839 bytes, checksum: c5836a71fbfccf7fea68838081ee8ff1 (MD5) Previous issue date: 2014
O objetivo deste estudo foi avaliar in vitro a influência da espessura de resina composta para esmalte, baseadas ou não na escala vita clássica nos parâmetros de luminosidade e translucidez. Um dispositivo de resina epóxica foi criado e confeccionado pelo método de estereolitografia para possibilitar a confecção de espécimes de resina composta em forma de um incisivo central superior que apresentavam as camadas de esmalte palatal, dentina e variação de três espessuras de esmalte vestibular: 0,4mm; 0,8mm e 1,2mm. Os materiais testados foram os compósitos, Filtek Z350 XT(3M ESPE), Miris 2(Coltène) e Ena HRi (Micerium). Foram feitas três leituras de cor para cada espécime utilizando o espectrofotômetro Vita Easy Shade (Vita Zahnfabrik). Pela análise estatística foram calculadas as médias das leituras e os parâmetros de translucidez e luminosidade. Os resultados mostram diferenças significativas entre os compósitos e entre as espessuras, sendo os maiores valores de luminosidade e menores graus de translucidez para o compósito Ena HRi e maiores valores de translucidez para o compósito Miris 2. Pode se concluir que os parâmetros de cor dependem do compósito utilizado e ainda da espessura utilizada.

Abstract: The aim of this study was to evaluate in vitro the translucency parameter and lightness using enamel composite resin with different thicknesses, based or not on the Vita Classical shade guide. An epoxic resin device was developed and built by stereolithography process to enable the manufacture of specimens with the shape of an upper central incisor using composite resin. The specimens had layers of palatal enamel, dentin, and three diferente thicknesses of buccal enamel: 0.4mm, 0.8mm and 1.2mm. The composites tested were Filtek Supreme Ultra (3M ESPE), Miris 2 (Coltène) and Ena HRi (Micerium). The spectrophotometer Vita Easy Shade Vita Zahnfabrik) was used to perform three color measurements of each specimen. Measurement means were calculated and through statistical analysis translucency parameter and lightness were also calculated. The results showed significant differences between the composites used and their thicknesses. The values of lightness were higher for lightness and the translucency was higher for the composite Miris 2. It can be concluded that the color parameters evaluated depend on the composite used and their thickness.
APA, Harvard, Vancouver, ISO, and other styles
11

Youssef, Mayssa. "Réseaux de Transport WDM: Planification de Réseaux Translucides et Economie d'Energie." Phd thesis, Télécom ParisTech, 2011. http://pastel.archives-ouvertes.fr/pastel-00680565.

Full text
Abstract:
Les réseaux d'opérateurs sont actuellement confrontés à multiples défis dont les coûts de réseaux, la disponibility, l'éco-durabilité et la qualité de service. Dans les réseaux "opaques", le signal optique est soumis à une régénération systématique à chaque passage par un noeud. Les réseaux "transparents" (ou tout-optiques) présentent une détérioration de la qualité du signal, due aux effets de dégradation par la couche physique s'accumulant depuis la source jusqu'à la destination. Les réseaux "translucides" offrent un compromis entre les deux types précédents. Dans de tels réseaux, une fraction des noeuds du réseau sont équipés de régénérateurs électriques, tandis que les autres sont complètement transparents aux signaux optiques. Dans un premier temps, nous avons proposé une technique d'optimisation pour la planification de réseaux translucides reposant sur une optimisation croisée entre les coûts CapEx et OpEx du réseau. L'algorithme développé fournit une solution pour le problème de routage et d'affectation de longueur d'onde tout en plaçant stratégiquement les régénérateurs. Dans un deuxième temps, nous avons étudié la planification de réseaux WDM tenant compte de la consommation énergétique, dans un contexte de trafic pré-planifié. Les cartes client servant d'interface entre le routeur IP et le switch optique présentent une opportunité pour réduire la consommation énergétique. Dans ce cadre, nous avons proposé une approche pour optimiser le nombre et l'utilisation de ces équipements en profitant de la corrélation spatio-temporelle entre les requêtes.
APA, Harvard, Vancouver, ISO, and other styles
12

Youssef, Mayssa. "Réseaux de transport WDM : planification de réseaux translucides et économie d'énergie." Paris, Télécom ParisTech, 2011. https://pastel.archives-ouvertes.fr/pastel-00680565.

Full text
Abstract:
Les réseaux d’opérateurs sont actuellement confrontés à multiples défis dont les coûts de réseaux, la disponibility, l’éco-durabilité et la qualité de service. Dans les réseaux « opaques », le signal optique est soumis à une régénération systématique à chaque passage par un nœud. Les réseaux « tranparents » (ou tout-optiques) présentent une détérioration de la qualité du signal, due aux effets de dégradation par la couche physique s’accumulant depuis la source jusqu’à la destination. Les réseaux « translucides » offrent un compromis entre les deux types précédents. Dans de tels réseaux, une fraction des nœuds du réseau sont équipés de régénérateurs électriques, tandis que les autres sont complètement transparents aux signaux optiques. Dans un premier temps, nous avons proposé une technique d’optimisation pour la planification de réseaux translucides reposant sur une optimisation croisée entre les coûts CapEx et OpEx du réseau. L’algorithme développé fournit une solution pour le problème de routage et d’affectation de longueur d’onde tout en plaçant stratégiquement les régénérateurs. Dans un deuxième temps, nous avons étudié la planification de réseaux VDM tenant compte de la consommation énergétique, dans un contexte de trafic pré-planifié. Les cartes client servant d’interface entre le routeur IP et le switch optique présentent une opportunité pour réduire la consommation énergétique. Dans ce cadre, nous avons proposé une approche pour optimiser le nombre et l’utilisation de ces équipements en profitant de la corrélation spatio-temporelle entre les requêtes
As operators strive today to optimize their networks, considerations of cost, availability, eco-sustainability, and quality of service are beginning to converge. Solutions that reduce capital and operational expenditures not only save money, but also tend to reduce the environmental impact. In “opaque” networks, optical signals undergo expensive electrical regeneration systematically at each node. In “transparent” networks, signal quality deteriorates due to the accumulation of physical impairments from source to destination. “Translucent” networks stand halfway between opaque and transparent networks. In such networks, sparsely chosen nodes are equipped with electrical regenerators while the others are transparent to the optical signal. In this thesis, we have proposed an proposed an optimization technique for translucent network design, and developed, for this purpose, an algorithm performing routing and wavelength assignement as well as regenerator placement consisting in a cross-optimization between CapEx and OpEx costs. The second part of this thesis focuses on energy-aware WDM network design applied to scheduled traffic. Client cards interfacing the IP router and the optical cross-connect represent the key elements which deployment can be exploited to prevent power waste. We have proposed an approach to optimize the number and usage of these components by addressing the time-space correlation between traffic connections
APA, Harvard, Vancouver, ISO, and other styles
13

Dey, Nicolas. "Etude de la formation de l'image d'un objet microscopique 3D translucide - Application à la microscopie." Phd thesis, Université du Maine, 2002. http://tel.archives-ouvertes.fr/tel-00003309.

Full text
Abstract:
Dans cette thèse, nous proposons un modèle complet de la formation de l'image, qui s'applique à des objets microscopiques 3D translucides.Dans notre modèle, un objet translucide est défini comme une répartition discrète d'indices de réfraction et de coefficients d'absorption. Pour simuler le trajet de la lumière, nous proposons un modèle physique utilisant des techniques de lancer de rayons de la source vers l'observateur. Ce modèle physique sert à calculer l'espace objet éclairé. Pour simuler la génération d'images par le système optique, nous utilisons des principes d'optique ondulatoire. Nous modélisons la fonction de transfert 3D du microscope, qui dépend de la défocalisation. Après avoir choisi un plan de focalisation, nous calculons une image simulée en appliquant cette fonction de transfert à chaque plan plus ou moins défocalisé de l'espace objet éclairé. Une séquence d'images simulées est obtenue en faisant varier la focalisation.
APA, Harvard, Vancouver, ISO, and other styles
14

Schulze, Lisanne [Verfasser]. "Establishing a new, genetically tractable vertebrate brain model with rich behaviour - Danionella translucida / Lisanne Schulze." Berlin : Medizinische Fakultät Charité - Universitätsmedizin Berlin, 2021. http://d-nb.info/1234984601/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Santos, Iuri Silveira dos. "TRANSLUCIDEZ E VALOR: ANÁLISE DO COMPORTAMENTO DAS PROPRIEDADES ÓPTICAS EM RESINAS COMPOSTAS ESTÉTICAS." Universidade Federal de Santa Maria, 2015. http://repositorio.ufsm.br/handle/1/6165.

Full text
Abstract:
This study aimed to evaluate the translucency and value with different combinations of enamel , dentin and body of each composite regarding a standard thickness (1,5mm). Three different resin composites commercially available with a standard shade (A1), IPS Empress Direct, Charisma Diamond and Filtek Z350 XT were evaluated. A stainless steel matrix was used to prepare ninety disc-shaped specimens with 11mm diameter and 1,5mm thickness. The specimens were randomly allocated in 18 groups (n=5) according to different combinations of enamel , dentin and body presented in each resin composite evaluated. After light curing, specimens were stored in deionized water at 37º C for 24h. Three consecutive readings were performed according to the CIE L*a*b* color scale relative to the standard illuminant D65 on reflection spectrophotometer (SP60 - EX-Rite). The optical properties of translucency and value were measured by the parameters translucency (TP) and lightness in white background (L*w) and black background (L*b), respectively. The mean TP, L*w and L*b were analyzed by ANOVA (General Linear Models) and Tukey s post hoc tests (α =0.05). Scatter plots together with Spearman´s correlation coefficient were used to assess the relationship between TP and L*w and TP and L*b values. The groups had statistical significant different values (p=0.000). The resin composite Empress Direct when only a layer of enamel were employed presented the highest TP value, whereas the resin composite Filtek Z350 XT with a single layer of dentin presented the lowest TP value. A negative and strong correlation between TP and L*b and a positive and weak correlation between TP and L*w were observed. Optical properties as translucency and value rely on the material used. In general, there was statistical difference between the groups for TP and L*
Este estudo tem como objetivo analisar o comportamento óptico de diferentes resinas compostas, em distintas combinações de esmalte, dentina e corpo de cada composto em relação à espessura padrão (1,5mm) na percepção da translucidez e valor. Foram analisadas três marcas comerciais de resina composta (IPS Empress Direct, Charisma Diamond, Filtek Z350 XT) na cor A1. Uma matriz metálica foi utilizada para confeccionar noventa espécimes (1,5mm de espessura e 11mm de diâmetro). Os espécimes foram randomizados e divididos em 18 grupos (n=5) conforme as possibilidades de combinações de esmalte, dentina e corpo. Após a fotopolimerização, os espécimes foram armazenados em água deionizada por 24h a 37°C. Três leituras consecutivas foram realizadas por um espectrofotômetro de reflexão (SP 60 EX-Rite) relativo ao iluminante padrão D65 de acordo com o sistema CIE L* a* b*. As propriedades ópticas, translucidez e valor, foram mensuradas pelo parâmetro de translucidez (TP) e pela variável L* sobre fundo preto e branco respectivamente. A média dos valores do TP, L*b e L*p foram analisadas por ANOVA (Modelo Linear Geral) e testes Tukey s post hoc (α=0,05). Gráficos de dispersão juntamente com o coeficiente de correlação de Spearman entre TP e L*p e TP e L*b foram calculados. Os grupos apresentaram diferença estatística (p = 0,000). A resina composta Empress Direct somente de esmalte apresentou o maior valor de TP, enquanto Filtek Z350 XT com uma única camada de dentina apresentou o menor valor de TP. Há uma forte correlação negativa entre TP e L*p e uma fraca correlação positiva entre TP e L*b. Propriedades ópticas de translucidez e valor são dependentes do material utilizado. De maneira geral, houve diferenças entre os grupos estudados quando analisados o TP e L*.
APA, Harvard, Vancouver, ISO, and other styles
16

Caneppele, Taciana Marco Ferraz [UNESP]. "Influência do clareamento dental na cor, translucidez e fluorescência do esmalte e dentina." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/101336.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-22Bitstream added on 2014-06-13T20:01:52Z : No. of bitstreams: 1 caneppele_tmf_dr_sjc.pdf: 1905463 bytes, checksum: e4c793381875beba7660a34d248f5267 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Objetivo:O objetivo deste estudo foi avaliar a cor, translucidez e fluorescência do esmalte e dentina bovinos submetidos a diferentes técnicas de clareamento. Material e Método: Foram utilizados 150 dentes bovinos, dos quais foram obtidos pares de discos de esmalte e dentina com 3mm de diâmetro. Em 75 pares, 1 dos espécimes teve o esmalte removido, sendo denominado Grupo Dentina. Os espécimes de dentina e esmalte obtidos do restante dos pares foram denominados Grupo Esmalte+dentina. E finalmente, 75 espécimes tiveram a dentina removida e foram denominados Grupo Esmalte. A medição da cor, translucidez e fluorescência foi realizada por um espectrofotômetro usando o CIE L * a * b*. Cada grupo foi subdividido em 3 subgrupos: Controle, composto por espécimes que não foram clareados e 2 sugrupos experimentais, clareados com Peróxido de Carbamida 10% (PC10%) ou Peróxido de hidrogênio a 35% (PH 35%). O gel clareador foi aplicado 2h/dia sobre os espécimes para o clareamento com PC10% durante 14 dias e duas aplicações de 30 min com intervalo de uma semana entre as aplicações no clareamento com PH35%. Nos períodos intermediários, os espécimes foram imersos em saliva artificial. As avaliações de cor foram realizadas 7 dias após o término do tratamento. Resultados: Em relação a cor, foram encontradas diferenças significativas entre as técnicas de clareamento nos grupos Esmalte e Esmalte + Dentina, com maior diferença de cor para o PH 35%. O clareamento não alterou a translucidez dos tecidos dentais e a fluorescência diminuiu, apresentando diferenças significantes para o Grupo Dentina, subgrupo PH 35%, Grupo Esmalte, subgrupo PC10% e Grupo Esmalte+dentina, subgrupo PH35%. Conclusão: O clareamento dental alterou a cor e a fluorescência dos tecidos dentais, porém a translucidez não foi afetada
Objective: The objective of this study was to evaluate the color, translucency and fluorescence of bovine enamel and dentin submitted to different bleaching modalities. Methods: A total of 150 bovine teeth were used, which were obtained pairs of enamel and dentin discs 3mm in diameter. In 75 pairs, one of the specimens had the enamel removed (Group Dentin). Specimens of dentin and enamel obtained from the remaining pair were named Group Enamel+dentin. And finally, 75 specimens were removed from the dentin and enamel were named Group Enamel. The measurement of color, translucency and fluorescence was performed by a spectrophotometer using the CIE L * a * b. Each group was subdivided into three subgroups: Control, composed of specimens that were not bleached and two experimental subgroups, bleached with carbamide peroxide 10% (CP10%) or hydrogen peroxide 35% (HP 35%). The whitening gel was applied on specimens for 2h/day bleaching with CP10% for 14 days and two applications of 30 minutes with one week interval between applications in bleaching with HP35%. In interim periods, the specimens were immersed in artificial saliva. The color ratings were performed 7 days after the treatment. Results: Regarding the color, significant differences were found among bleaching techniques in the groups enamel and dentin + enamel, with a higher color difference for the 35% HP. Bleaching did not change the translucency of the dental tissues and the fluorescence showed significant differences for the 35% HP subgroups in Dentin and Enamel+dentin group, and for 10%CP subgroups in Enamel group. Conclusion: The dental bleaching changed the color and fluorescence of the dental tissues, however translucency was not affected
APA, Harvard, Vancouver, ISO, and other styles
17

Caneppele, Taciana Marco Ferraz. "Influência do clareamento dental na cor, translucidez e fluorescência do esmalte e dentina /." São José dos Campos : [s.n.], 2011. http://hdl.handle.net/11449/101336.

Full text
Abstract:
Orientador: Carlos Rocha Gomes Torres
Banca: Alessandra Bühler Borges
Banca: Sergio Eduardo de Paiva Gonçalves
Banca: Glauco Fioranelli Vieira
Banca: Osmir Batista de Oliveira
Resumo: O objetivo deste estudo foi avaliar a cor, translucidez e fluorescência do esmalte e dentina bovinos submetidos a diferentes técnicas de clareamento. Material e Método: Foram utilizados 150 dentes bovinos, dos quais foram obtidos pares de discos de esmalte e dentina com 3mm de diâmetro. Em 75 pares, 1 dos espécimes teve o esmalte removido, sendo denominado Grupo Dentina. Os espécimes de dentina e esmalte obtidos do restante dos pares foram denominados Grupo Esmalte+dentina. E finalmente, 75 espécimes tiveram a dentina removida e foram denominados Grupo Esmalte. A medição da cor, translucidez e fluorescência foi realizada por um espectrofotômetro usando o CIE L * a * b*. Cada grupo foi subdividido em 3 subgrupos: Controle, composto por espécimes que não foram clareados e 2 sugrupos experimentais, clareados com Peróxido de Carbamida 10% (PC10%) ou Peróxido de hidrogênio a 35% (PH 35%). O gel clareador foi aplicado 2h/dia sobre os espécimes para o clareamento com PC10% durante 14 dias e duas aplicações de 30 min com intervalo de uma semana entre as aplicações no clareamento com PH35%. Nos períodos intermediários, os espécimes foram imersos em saliva artificial. As avaliações de cor foram realizadas 7 dias após o término do tratamento. Resultados: Em relação a cor, foram encontradas diferenças significativas entre as técnicas de clareamento nos grupos Esmalte e Esmalte + Dentina, com maior diferença de cor para o PH 35%. O clareamento não alterou a translucidez dos tecidos dentais e a fluorescência diminuiu, apresentando diferenças significantes para o Grupo Dentina, subgrupo PH 35%, Grupo Esmalte, subgrupo PC10% e Grupo Esmalte+dentina, subgrupo PH35%. Conclusão: O clareamento dental alterou a cor e a fluorescência dos tecidos dentais, porém a translucidez não foi afetada
Abstract: The objective of this study was to evaluate the color, translucency and fluorescence of bovine enamel and dentin submitted to different bleaching modalities. Methods: A total of 150 bovine teeth were used, which were obtained pairs of enamel and dentin discs 3mm in diameter. In 75 pairs, one of the specimens had the enamel removed (Group Dentin). Specimens of dentin and enamel obtained from the remaining pair were named Group Enamel+dentin. And finally, 75 specimens were removed from the dentin and enamel were named Group Enamel. The measurement of color, translucency and fluorescence was performed by a spectrophotometer using the CIE L * a * b. Each group was subdivided into three subgroups: Control, composed of specimens that were not bleached and two experimental subgroups, bleached with carbamide peroxide 10% (CP10%) or hydrogen peroxide 35% (HP 35%). The whitening gel was applied on specimens for 2h/day bleaching with CP10% for 14 days and two applications of 30 minutes with one week interval between applications in bleaching with HP35%. In interim periods, the specimens were immersed in artificial saliva. The color ratings were performed 7 days after the treatment. Results: Regarding the color, significant differences were found among bleaching techniques in the groups enamel and dentin + enamel, with a higher color difference for the 35% HP. Bleaching did not change the translucency of the dental tissues and the fluorescence showed significant differences for the 35% HP subgroups in Dentin and Enamel+dentin group, and for 10%CP subgroups in Enamel group. Conclusion: The dental bleaching changed the color and fluorescence of the dental tissues, however translucency was not affected
Doutor
APA, Harvard, Vancouver, ISO, and other styles
18

Queiroz, Renato Souza [UNESP]. "Análise comparativa da transmitância de diferentes tipos de resina composta pelo método de espectrofotometria de luz visível." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/89639.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T19:10:18Z : No. of bitstreams: 1 queiroz_rs_me_arafo.pdf: 1256542 bytes, checksum: fc1faa7ab6e3827911b6c0203d2355cf (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Foi avaliada comparativamente, pelo método de espectrofotometria de luz visível, a transmitância de 7 diferentes resinas compostas: G1- Charisma A2; G2-Filtek Supreme A2E; G3- Filtek Supreme A2B; G4- Filtek Supreme YT; G5- Esthet-X A2; G6- Esthet-X YE; G7- Durafill A2, e G8- Z-100 A2. Foram confeccionados 10 corpos de prova para cada grupo experimental com 10 mm de diâmetro e 2 mm de espessura. As amostras foram avaliadas em 3 períodos (inicial, antes da imersão, 24h e 10 dias após imersão em saliva artificial). Os valores obtidos pela transmitância direta, nos comprimentos de onda de 460 a 640 nm, foram submetidos à análise de variância a dois critéiros e teste de Tukey. Os resultados evidenciaram uma homogeneidade de valores entre as amostras e em função do tempo. Pode-se concluir que os valores de transmitância aumentaram significativamente conforme se aumentou os comprimentos de onda de 460 a 640 nm; O comportamento dos grupos experimentais foi similar em função do tempo, sendo que no tempo inicial e após 10 dias os resultados foram semelhantes entre si e estatisticamente superiores aos valores obtidos após 24 horas de imersão; O grupo G4 apresentou sempre a maior média de transmitância ao longo dos comprimentos de onda, em todos os tempos; Os grupos G6 e G7 foram semelhantes entre si com relação à transmitância e superiores aos grupos em ordem crescente de transmitância por G8=G2=G1>(G5=G3).
It was evaluated comparatively with ultra-visible spectrophotometer, the transmittance of 7 different composite resins: G1- Charisma A2; G2-Filtek Supreme A2E; G3- Filtek Supreme A2B; G4- Filtek Supreme YT; G5- Esthet-X A2; G6- Esthet-X YE; G7- Durafill A2, e G8- Z-100 A2.Ten samples (10 mm of diameter and 2 mm of thickness) were made for each experimental group. The samples were evaluated in 3 periods (initial, before the immersion, 24h and 10 days after immersion in artificial saliva). The values of the direct transmittance, in the wave lengths of 460 the 640 nm, were submitted to the two-way analysis of variance and Tukey's intervals. The results had evidenced homogeneity of values between the samples in function and of the time. It can be concluded that the values of transmittance had increased significantly if increased the wave lengths of 460 the 640 nm; The experimental groups reveled similar values in function of the time; the initial time and 10 days after immersion, the results had been similar between itself and superior to the values after 24 hours of immersion; The G4 group always presented the average greater of transmittance to the long one of the wave lengths, in all the times; The groups G6 and G7 had been similar between itself with relation to the transmittance and superiors to the groups orderly increasing of transmittance for G8=G2=G1>(G5=G3).
APA, Harvard, Vancouver, ISO, and other styles
19

Simonot, Lionel. "Etude expérimentale et modélisation de la diffusion de la lumière dans une couche de peinture colorée et translucide." Phd thesis, Université Pierre et Marie Curie - Paris VI, 2002. http://tel.archives-ouvertes.fr/tel-00002238.

Full text
Abstract:
Les glacis sont des couches picturales translucides volontairement colorées utilisées dès le XVe siècle par les Primitifs Flamands. Constituée de pigments dispersés dans un liant à base d'huile de lin cuite, une couche de glacis donne à un tableau un caractère saisissant car la couleur se construit à l'intérieur du volume constitué par la couche. Pour comprendre cet effet visuel particulier et le décrire quantitativement, nous étudions la répartition angulaire et spectrale de la lumière diffusée par des glacis : expérimentalement, par des mesures goniospectrophotométriques en rétrodiffusion et bidirectionnelles sur des échantillons réalisés par un peintre contemporain ; en proposant une modélisation de la diffusion multiple incohérente de la lumière au sein de la matière ; ceci amène à résoudre l'équation de transfert radiatif (ETR) et à déterminer les propriétés physiques du glacis. Une nouvelle méthode de résolution de l'ETR, la méthode de la fonction auxiliaire, permet d'exprimer les flux lumineux diffusés en fonction des angles d'incidence et d'observation. Contrairement à la première et seule modélisation appliquée aux œuvres d'art existant et datant de 1931, nous obtenons une modélisation bidirectionnelle validée par comparaison avec les résultats expérimentaux. Dans le cas particulier des vernis, couches non diffusantes, une expression analytique du facteur de réflectance est obtenue. Les flux lumineux mesurés et simulés permettent de chiffrer l'apparence visuelle des glacis. Il est alors possible de quantifier la modulation de leur couleur en fonction du nombre de couches superposées ou bien le brillant favorisé par la surface externe lisse des fines couches de glacis. Des applications sont alors envisageables pour la conservation et la restauration des œuvres d'art comme, par exemple, la prédiction de l'aspect visuel d'une restauration.
APA, Harvard, Vancouver, ISO, and other styles
20

Morea, Annalisa. "Étude des réseaux optiques translucides : évaluation de leur faisabilité et de leur intérêt économique /." Paris : École nationale supérieure des télécommunications, 2008. http://catalogue.bnf.fr/ark:/12148/cb41246298b.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Morea, Annalisa. "Étude des réseaux optiques translucides : évaluation de leur faisabilité et de leur intérêt économique." Paris, ENST, 2006. http://www.theses.fr/2006ENST0050.

Full text
Abstract:
L’apparition et la maîtrise des nouvelles technologies optiques pour la transmission et le brassage des signaux dans un réseau optique permettent l’introduction de la transparence dans le réseau cœur. Un réseau est dit transparent, si les signaux optiques transportés ne subissent aucune conversion optoélectronique sauf pour leur insertion et extraction. Un réseau translucide est à mi-chemin entre un réseau opaque (conversion optoélectronique systématique dans chaque nœud) et un réseau transparent. Ce dernier constitue un compromis entre le cas complètement transparent et celui opaque. Il permet : La réduction du besoin de dispositifs optoélectroniques sans poser des contraintes rédhibitoires quant à la portée géographique des connexions dans le réseau et à la continuité de la longueur d’onde qui leur est associée. Un réseau translucide assure un bon compromis entre la qualité des signaux optiques en réception et le coût total de mise en œuvre du réseau. Le fonctionnement du réseau indépendamment de certaines caractéristiques des signaux transportés (débit associé, format de modulation, …). Un réseau translucide permet donc une plus grande adaptabilité à l’évolution du trafic que ne permet un réseau opaque. Ces aspects rendent le concept de réseau translucide très attractif pour un opérateur, tel que France Télécom. Le but de cette thèse est de déterminer la faisabilité des réseaux translucides eu égard aux topologies existantes des réseaux dorsaux d’opérateur ainsi qu’aux caractéristiques des équipements du marché. L’originalité de l’étude réside dans l’analyse technico-économique des contraintes physiques couplées aux règles de dimensionnement d’un réseau translucide
The arrival and mastery of new optical transmission technologies and all-optical switching of signals in optical networks allow the introduction of transparency in the core network. In transparent networks, optical signals are not converted to electronic signals except when added or dropped. A translucent transport network is half way between an opaque network (systematic opto-electrical conversion at each node) and a transparent network. This type of network provides a trade-off between transparency and opacity and permits : Alleviate the need for opto-electrical devices without restricting either the length of connexions in the network or the wavelength constraint, assuring a balance between signal performance at reception and total network cost. Operation of the network independent of certain signal characteristics (bit rate, modulation, etc) making the network more adaptive to developments. These aspects make this type of network very attractive for providers, such as France Télécom. The goal of this thesis is to determine network feasibility and the advantages that could be brought to the backbone network. This study is original in the use of physical constraints linked to network dimensioning; these features are the main research axes of the present work
APA, Harvard, Vancouver, ISO, and other styles
22

Rodrigues, Neto Elídio [UNESP]. "Avaliação da influência do selante de superfície sobre a translucidez de resina composta. Efeito de tempos e soluções." Universidade Estadual Paulista (UNESP), 2004. http://hdl.handle.net/11449/89654.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-20Bitstream added on 2014-06-13T19:10:20Z : No. of bitstreams: 1 rodriguesneto_e_me_arafo.pdf: 296469 bytes, checksum: 46a2478fea941cbd45701b60eb5dbff8 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O presente trabalho teve como objetivo avaliar o efeito do selante de superfície sobre a translucidez da resina composta, em função das soluções e do tempo de imersão. Para isso foram selecionados os seguintes materiais: resina composta Charisma; selante de superfície Fortify; e quatro soluções para imersão, café, Coca-Cola®, chá e Saliva Artificial. Foram confeccionados 8 corpos-de-prova para cada condição experimental, totalizando 64 corpos-de-prova. A partir disso, os mesmos permaneceram imersos em saliva artificial, mantidos em estufa a uma temperatura de 37ºCl 1, e foram retirados da estufa para imersão nas soluções testadas, três vezes ao dia por um período de cinco minutos, e após este período foram lavados em água corrente e novamente imersos em saliva artificial, até o momento determinado para a leitura da translucidez. As leituras foram realizadas em nove níveis: T1 - após a confecção dos corpos-de-prova, T2 - 24 horas após a imersão nas soluções, T3 - 48 horas após, T4 a T9, sendo respectivamente 7, 14, 21, 30, 60 e 90 dias após a imersão. Para a obtenção dos valores de translucidez (em porcentagem) foi utilizado o aparelho JOUAN. Os resultados obtidos foram submetidos à Análise de Variância e ao Teste de Tukey a 5%. Observou-se que as soluções influenciaram na translucidez dos materiais (p<0,001), sendo que o café apresentou maior ação pigmentante, seguido pelo chá, Coca-Cola® e saliva artificial. Com relação ao tempo notou-se que a partir de T5 houve uma significante alteração (p<0,001) na translucidez da resina até T8. E quanto ao selante o grupo selado apresentou maiores valores de translucidez (p<0,05) do que o grupo não selado. Mediante a metodologia aplicada pode-se concluir que o café foi a solução que promoveu maior alteração de translucidez, a resina composta sofreu alteração significativa... .
The aim of the current study was to evaluate the surface sealant effect upon the composite resin translucence, related to different solutions and immersion periods. The following materials were selected: Charisma composite resin; Fortify surface sealant; and four immersion solutions, which are coffee, Coca-Cola®, tea and Artificial Saliva. Eight test specimens were manufactured for each experimental condition, totaling 64 test specimens. All the specimens were immersed in artificial saliva and maintained in a kiln at 37ºCl 1, being then removed for a five-minute immersion period three times a day in the solutions tested, after which they were washed with tap water and immersed in artificial saliva once more until the translucence reading was performed. The readings were performed in nine levels: T1 - after test specimens manufacture, T2 - 24 hours after the immersion in the solutions, T3 - 48 hours after the immersion, T4 to T9, respectively 7, 14, 21, 30, 60 and 90 days after the immersion. In order to achieve translucence scores (in percentage), the appliance JOUAN was used. The results obtained were submitted to the Analysis of Variance and to Tukey's test at 5%. It was possible to observe that the solutions influenced on the materials translucence (p<0.001), and that coffee showed the most staining action, followed by tea, Coca-Cola® and artificial saliva. In regard to time, a significant alteration (p<0.001) was noticed in the composite resin from T5 up to T8. Considering the sealant, the sealed group showed higher scores of translucence (p<0.05) than the non-sealed group. According to the methodology applied, it is possible to conclude that coffee was the solution which provided the most intense translucence alteration, the composite resin underwent a significant alteration in translucence after 21 days of... (Complete abstract, click electronic address below).
APA, Harvard, Vancouver, ISO, and other styles
23

Morea, Annalisa. "Etude des réseaux optiques translucides : évaluation de leur faisabilité technique et de leur intérêt économique." Phd thesis, Télécom ParisTech, 2006. http://pastel.archives-ouvertes.fr/pastel-00003161.

Full text
Abstract:
L'apparition et la maîtrise des nouvelles technologies optiques pour la transmission et le brassage des signaux dans un réseau optique permettent l'introduction de la transparence dans le réseau cœur. Un réseau est dit transparent, si les signaux optiques transportés ne subissent aucune conversion optoélectronique sauf au moment de leur insertion et de leur extraction. Un réseau de transport translucide est à mi-chemin entre un réseau opaque (conversion optoélectronique systématique dans chaque nœud) et un réseau transparent. Ce type de réseau constitue un compromis entre le cas complètement transparent et le cas opaque. Il permet : · La réduction du besoin de dispositifs optoélectroniques sans poser des contraintes rédhibitoires quant à la portée géographique des connexions dans le réseau et à la continuité de la longueur d'onde qui leur est associée. Un réseau translucide assure un bon compromis entre la qualité des signaux optiques en réception et le coût total de mise en œuvre du réseau. · Le fonctionnement du réseau indépendamment de certaines caractéristiques des signaux transportés (débit associé, format de modulation,
APA, Harvard, Vancouver, ISO, and other styles
24

Sardeiro, Paula Silva. "Parametros para a escolha de superficies translucidas visando o conforto termico e visual na edificação." [s.n.], 2007. http://repositorio.unicamp.br/jspui/handle/REPOSIP/258674.

Full text
Abstract:
Orientador: Rosana Maria Caram de Assis
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo
Made available in DSpace on 2018-08-09T23:46:11Z (GMT). No. of bitstreams: 1 Sardeiro_PaulaSilva_D.pdf: 4278471 bytes, checksum: caae243c104fee90280a8154d5e47b08 (MD5) Previous issue date: 2007
Resumo A escolha de trabalhar com os vidros translúcidos e policarbonatos alveolares ocorreu devido à inexistência de pesquisas na área e por estar sendo ostensivamente utilizados na Europa e Estados Unidos e, no país, vem ganhando espaço nas fachadas das edificações desde a década de 90, como um material renovado e inédito. Conseqüentemente, percebe-se a necessidade de caracterizar este material diante da radiação solar, levando em consideração o conforto térmico e visual no interior da edificação. Para tanto, foram realizadas medições em laboratórios, por meio do espectrofotômetro e do rugosímetro, como também medições in loco, através de células-teste. No laboratório foram realizadas medições de transmissão da radiação nos vidros e policarbonatos alveolares, com o espectrofotômetro; e medições do perfil dos vidros com o rugosímetro. Nas células-teste foram medidas a temperatura interna e externa do ar, a temperatura superficial interna e externa do vidro e a temperatura da parede oposta a janela. Obteve-se resultados inéditos, caracterizando a transmissão para cada região específica: ultravioleta, visível e infravermelho, verificando os parâmetros térmicos e luminosos. A rugosidade da superfície do vidro tem poder decisivo na questão da transmissão da radiação. Nas células-teste fechadas com os vidros translúcidos com menores valores referentes ao Profile Rugose Total - PRT foram registrados os maiores valores relativos à temperatura interna do ar. Formulam-se recomendações que servirão de subsídios na especificação e na indicação de superfícies translúcidas para arquitetos e projetistas, levando em consideração o térmico e o visual; e, também, divulgam-se informações técnicas que são escassas na literatura nacional e internacional
Abstract: This paper is directed towards translucent glasses and alveolar polycarbonates due to the lack of extensive research in this field. Nonetheless, these materials have been ostensively used in Europe and United States. In Brazil, translucent glasses and alveolar polycarbonates have been increasingly applied to building facades since the decade of 90¿s as a novel and renewed material. Thus, it is important to characterize translucent glasses and alveolar polycarbonates before solar radiation considering the thermal and visual comfort inside the building. In order to do so, laboratory measurements were performed using a spectrophometer to measure the glass transmission and a profilometer to measure the glass profiles. In loco measurements were also carried out through test cells in which the air, glass surface and wall temperatures were evaluated. The novel results characterized the transmission to each specific region, ultraviolet, visible and infrared, which verified the thermal and visual parameters. The glass surface roughness has a distinguished influence on the radiation transmission. The test cells closed with translucent glass of the lowest PRT values demonstrated the highest values of internal air temperature. It was possible to elaborate recommendations that will serve as groundwork for architects and designers in the specification and indication of translucent surfaces taking into account the thermal and visual comfort. At last, the results also contributed to disclose technical information that is scarce in the national and international literature
Doutorado
Arquitetura e Construção
Doutor em Engenharia Civil
APA, Harvard, Vancouver, ISO, and other styles
25

Kaizer, Marina da Rosa. "TRANSLUCIDEZ DE RESINAS COMPOSTAS CONSTITUÍDAS POR DIFERENTES MONÔMEROS EM MEIOS E TEMPOS DE ARMAZENAMENTO DISTINTOS." Universidade Federal de Santa Maria, 2010. http://repositorio.ufsm.br/handle/1/6071.

Full text
Abstract:
The aim of this study was to determine translucency of composite resins formed by different monomers when stored in two distinct environments (immersed in dis tilled water and red wine) and periods of time (immediately after curing, 24h and 30 days). Also two methods for translucency evaluation (Translucency Parameter and Percentage of Opacity) were compared. Three composite resins were tested: one silorane-based (Filtek P90) and two metacrilate-based (Filtek Z350 and Rok). Fourteen specimens (sp) were made for each composite using a metallic matrix with 10 mm of diameter and 2 mm of thickness. Immediately after light curing using a LED (±800mW/cm2) for 40 seconds, sp were polished with Sof-Lex Pop On Orange Series discs and with felt and diamond paste, then sp were washed in water and dried. Immediately after polishing, the initial translucency was measured with the spectrophotometer SP60 - X-Rite using the CIE L * a * b * system. Then the sp of each composite resin was divided into two groups (n = 7) according to the storage media. Successive readings were conducted in periods of 24 hours and 30 days. Data were submitted to ANOVA and Tukey s test (5%) to compare the means of the groups. The silorane-based composite resin showed less translucency changes than metacrilate-based resins, only when stored in wine. In deionized water the modification of P90 was greater than other resins, improving the translucency. All composites presented more alteration when stored in wine than in water, and such variation was higher in longer periods of storage. No differences were found between the methods of evaluation. Both methods of translucency evaluation demonstrated similar results. The translucency of composites was more affected by the red wine than by the water and the longer the period of contact with this substance the greater the modification. The type of monomer seems to be a factor that will influence the translucency changes of composite resins. The variation of translucency can be measured by the two tested methods
O objetivo deste trabalho foi verificar a translucidez de resinas compostas constituídas por diferentes monômeros, quando armazenadas em meios (imersos em água e em vinho tinto suave) e períodos distintos (imediatamente após a fotoativação, 24h e 30 dias). Também foram comparados dois métodos de análise de translucidez (Parâmetro de Translucidez e o Percentual de Opacidade) das resinas compostas. Três resinas compostas foram utilizadas, uma a base de silorano (Filtek P90) e duas a base de metacrilatos (Filtek Z350 e Rok). Foram confeccionados 14 corpos-de-prova (cps) para cada resina composta, utilizando uma matriz metálica com 10 mm de diâmetro e 2 mm de espessura. Imediatamente após a fotoativação com uma fonte de luz LED (±800mW/cm2), por 40s, os cps foram polidos com discos Sof-Lex Pop On e disco de feltro com pasta diamantada, lavados em água e secos com gaze. A translucidez inicial dos cps foi aferida imediatamente após o polimento com o espectrofotômetro SP60 - X-Rite, utilizando o sistema CIE L* a* b*. Os cps de cada resina composta foram divididos em dois grupos (n=7) de acordo com os meios de armazenamento. Sucessivas leituras foram realizadas nos períodos de 24h e 30 dias. Os dados foram submetidos à Análise de Variância e Teste de Tukey (5%). A resina a base de silorano apresentou menor variação de translucidez, que as resinas a base de metacrilatos, apenas, quando armazenada em vinho. Já em água deionizada, a variação da P90 foi maior que nas demais, ficando mais translucida. Todas as resinas apresentaram maior alteração de translucidez, quando armazenadas em vinho do que em água, e esta variação foi maior no período de trinta dias. O tipo de monômero parece ser um fator que irá influenciar a variação da translucidez da resina composta. A variação de translucidez pôde ser aferida pelos dois métodos testados de forma semelhante.
APA, Harvard, Vancouver, ISO, and other styles
26

Dal, Piva Amanda Maria de Oliveira. "Influência da espessura da cerâmica no comportamento biomecânico, sobrevivência e na translucidez de coroas monolíticas /." São José dos Campos, 2020. http://hdl.handle.net/11449/192601.

Full text
Abstract:
Orientador: Marco Antonio [Unesp] Bottino
Resumo: Apesar do aumento do uso de coroas monolíticas, seu desempenho, em diferentes aspectos, ainda não foi determinado. Inicialmente, este projeto investigou o comportamento biomecânico de diferentes coroas monolíticas convencionais sobre dentes e a distribuição de tensões na camada de cimento (Artigo 1). Como objetivo principal, este estudo avaliou o efeito do princípio do mínimo preparo dental no comportamento biomecânico, confiabilidade e translucidez de coroas monolíticas posteriores em cerâmica. No entanto, para definir o substrato a ser utilizado para receber as coroas usinadas, uma análise complementar foi desenvolvida para observar o comportamento da restauração sobre diferentes substratos através da análise por elementos finitos (Artigo 2). E para o Artigo 3, cento e vinte e seis coroas foram fabricadas e divididas (n = 21 / gr) de acordo com o material (zircônia de alta translucidez -YZHT, silicato de lítio reforçado com zircônia - ZLS e cerâmica híbrida -HC) e espessura (0,5 – subgrupo .5 ou 1 mm – subgrupo 1). A concentração de tensão de tração foi calculada pelo método dos elementos finitos, as coroas adesivamente cimentadas foram fadigadas pelo teste step-stress para calcular a confiabilidade de missões a 600 e 900 N a 100.000 ciclos; e, a translucidez foi analisada em 10 discos de cada material e espessura. Maior concentração de tensão de tração foi observada em coroas mais finas e com módulo de elasticidade mais alto. As coroas YZHT foram suspensas quando a fadiga ... (Resumo completo, clicar acesso eletrônico abaixo)
Doutor
APA, Harvard, Vancouver, ISO, and other styles
27

Silami, Francisca Daniele Jardilino. "Influência dos cimentos resinosos e sistemas cerâmicos na translucidez e estabilidade de cor de restaurações laminadas." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/58/58131/tde-21052018-141131/.

Full text
Abstract:
O objetivo desse estudo foi avaliar o grau de conversão, a estabilidade de cor e translucidez de cimentos resinosos para cimentação de laminados cerâmicos em duas espessuras, submetidos a diferentes protocolos de envelhecimento. Foram utilizados 270 incisivos bovinos hígidos, cujas porções radiculares foram cortadas e as porções coronárias foram incluídas em matriz de PVC (25mm de diâmetro) com resina acrílica. As faces vestibulares foram planificadas até a dentina. Foram confeccionados 240 corpos-de-prova em cerâmica prensada (IPS e-max Press e IPS e- maxZirpress, IvoclarVivadent), em duas espessuras (0,5 mm e 1,0 mm), que foram separados aleatoriamente em dois grupos, segundo o tipo de cimento resinoso utilizado para fixação: fotoativado (Variolink II, Ivoclar/Vivadent) ou dual (Rely U 200, 3M ESPE). Após a cimentação, todas as amostras foram mantidas em estufa a 37°C por 24h, após o qual foram realizadas as leituras de cor e translucidez iniciais (Vita EasyShade, VITA). Em seguida, as amostras foram subdivididas em três grupos (n=10) de acordo com o envelhecimento a que foram submetidos: Controle sem envelhecimento; imersão em água destilada por 1 ano e fadiga termomecânica (1.200.000 ciclos, frequência de1,3Hz e ciclagem térmica de 5°C/37°C/55°C). Como controle, foram obtidos 30 corpos-de-prova de cada cimento resinoso (0,5mm) e 30 dentes foram planificados e submetidos aos mesmos processos de envelhecimento, após o qual leituras finais foram realizadas. Foram analisados também o grau de conversão dos cimentos polimerizados através das restaurações (FTIR) e a linha de cimentação em cada um dos grupos (n=3), antes e depois do envelhecimento. Para isso, as amostras, selecionadas aleatoriamente, foram seccionadas no sentido longitudinal e analisadas em estereomicroscópio de dupla coordenada (Nikon Measurescope). Os dados de estabilidade de cor (ΔE), translucidez, grau de conversão e linha de cimentação foram submetidas à análise estatística (3-way ANOVA, Tukey, p<0,05). O cimento autoadesivo apresentou maior grau de conversão que o fotoativado (p<0,05) quando utilizada a cerâmica Zirpress, mas produziu maior alteração de cor (p<0,05) e menor translucidez nas restaurações de E-maxPress de 0,5mm. A ciclagem termomecânica não foi significante para alterações óticas dos sistemas cerâmicos testados. Conclui-se que a espessura do laminado cerâmico não altera o grau de conversão dos cimentos resinosos e o tipo de cimento resinoso influencia a estabilidade de cor das restaurações cerâmicas quando submetido ao envelhecimento com água destilada.
The aim of this study is to evaluate the degree of conversion, color stability and translucency of resin cement for luting ceramic veneers with two thicknesses submitted to different aging protocols. Two hundred and seventy bovine incisors were used, which had the root cut, and the coronal were embedded in acrylic resin into PVC rings (25mm diameter). The buccal surface was flattened until dentin. Two hundred and forty pressed ceramic veneers (IPS e-max Press and IPS e-max ZirPress, IvoclarVivadent) were obtained, in two thicknesses (0,5 mm and 1.0 mm), that were randomly separated into two groups according to the type of resin cement used for luting: light-cured (Variolink II, Ivoclar / Vivadent) or dual cured (Rely U 200, 3M ESPE). After the cementation, all samples were maintained at 37 °C for 24 h; after first color and translucency readings (Vita EasyShade, VITA) were made. The samples were separated into 3 groups (n=10) according to the aging that was submitted: control without aging, immersion in distilled water for one year and thermomechanical cycling (1.200.000 cycles, frequency of 1,3Hz and thermal cycling of 5°C/37°C/55°C). As the control group, 30 samples of each resin cement (0,5 mm) and flattened teeth were obtained and submitted to the same aging protocols. After tests, the final color and translucency readings were taken. The degree of conversion of resin cements through veneer restoration, and the cement film thickness (n=3) for each group were analyzed (FTIR), before and after aging. For this, the samples were randomly selected, sectioned longitudinally and examined by a stereomicroscope (Nikon Measurescope). The results of color stability (ΔE), translucency, degree of conversion and cement film thicknesses were statistically analyzed (3-way, ANOVA, Tukey, p<0.05). The self-adhesive cement showed the higher degree of conversion than light-activated luting cement (p<0.05) when Zirpress ceramic was used, but produced higher color change (p<0.05) and lower translucency in 0.5mm E-maxPress restorations. The thermomechanical cycling was not significant for optical changes of tested ceramic systems. It was concluded that the thickness of ceramic veneers didnt alter the degree of conversion of resin cement and the type of resin cement has influenced the color stability of ceramic restorations when submitted to water aging.
APA, Harvard, Vancouver, ISO, and other styles
28

Augusto, Jean Carlo Duarte [UNESP]. "Avaliação in vitro da translucidez de dois sistemas cerâmicos metal-free: In-Ceram x Empress 2." Universidade Estadual Paulista (UNESP), 2004. http://hdl.handle.net/11449/89656.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-08-31Bitstream added on 2014-06-13T19:51:24Z : No. of bitstreams: 1 augusto_jcd_me_arafo.pdf: 977646 bytes, checksum: be6532503de67df201b656b4dc100b31 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Os sistemas cerâmicos metal-free são materiais odontológicos restauradores indiretos com excelentes propriedades ópticas, mecânicas e biológicas. As indicações destes materiais têm uma relevância clínica fundamental nos dias atuais, visto que, as expectativas dos pacientes por excelentes resultados estéticos são cada vez maiores. Conhecer amplamente as propriedades destes materiais é importante na evolução da área odontológica. O objetivo deste trabalho foi realizar, in vitro, uma comparação da propriedade óptica de translucidez de dois sistemas cerâmicos metal-free amplamente utilizados nos consultórios odontológicos (In-Ceram e Empress 2) comparando grupos de estudo que representassem quadros próximos às situações clínicas, produzindo amostras dos materiais estudados na espessura em que são indicados pelos fabricantes, ou seja, 0,5 mm para a infra-estrutura ou coping do In-Ceram, e 0,8 mm para a infra-estrutura do Empress 2. Foi produzido um grupo experimental com o material de Empress 2 na espessura de 0,5 mm, para ter-se um parâmetro de comparação dos dois materiais na mesma espessura. Nesta fase, todos os corpos de prova foram submetidos às leituras de translucidez, com o emprego do aparelho Jouan. Os corpos de prova foram, em uma etapa seguinte, cobertos pela cerâmica de estratificação para compararmos a situação clínica final de uma restauração indireta. Produziram-se corpos de prova com a espessura de 1,5 mm, e nova leitura da translucidez foi realizada. Esses corpos de prova receberam então o tratamento de glazeamento na face em que haviam sido cobertos com a cerâmica de estratificação, e foi realizada a última leitura da translucidez destes materiais. Os resultados, segundo a metodologia empregada, mostraram que, o Sistema Empress 2 apresenta índices translucidez superiores ao In-Ceram. Quando comparados os materiais de...
All-ceramic systems are indirect restoring materials with excellent optical, mechanical and biological properties. The use of those materials have a fundamental clinical relevance nowadays, since the patients expectations for best esthetical results are increasing. Deep knowledge of these materials properties is very important to odontology area evolution. The objective of this work was to make an in vitro comparison on translucency optical property of two all-ceramic systems often used at dental offices (In-Ceram and Empress 2) when searching for excellence on esthetical results. This work tried to compare studying groups that represented characteristics approximate to clinical situations, producing samples of studied materials at thickness recommended by manufacturer's, that is, 0,5 mm for the core materials or coping of In-Ceram, and 0,8 mm for the Empress 2. It was produced an experimental group with the Empress 2 material at thickness of 0,5 mm, in order to provide a comparison parameter for both materials at the same thickness. At this phase, all the disc specimens were submitted to quantitative measurement of translucency, using Jouan equipment. In the next phase, the disc specimens were veneered with stratification ceramic so we could compare the final clinical situation of an indirect restoration. Disc specimens were produced with thickness of 1,5 mm, and a new measurement of translucency was made. These samples then received a glazing cycle on the side that were veneered with stratification ceramic, and finally we made the last measurement of translucency on these materials. The results, according to adopted methodology, showed that the Empress 2 System presents greater translucency than In-Ceram System. When the core materials were compared, one can establishes that: translucency index of Empress 2 (0,5 mm) > Empress 2 (0,8 mm)... (Complete abstract, click electronic address below)
APA, Harvard, Vancouver, ISO, and other styles
29

Augusto, Jean Carlo Duarte. "Avaliação in vitro da translucidez de dois sistemas cerâmicos metal-free : In-Ceram x Empress 2 /." Araraquara : [s.n.], 2004. http://hdl.handle.net/11449/89656.

Full text
Abstract:
Resumo: Os sistemas cerâmicos metal-free são materiais odontológicos restauradores indiretos com excelentes propriedades ópticas, mecânicas e biológicas. As indicações destes materiais têm uma relevância clínica fundamental nos dias atuais, visto que, as expectativas dos pacientes por excelentes resultados estéticos são cada vez maiores. Conhecer amplamente as propriedades destes materiais é importante na evolução da área odontológica. O objetivo deste trabalho foi realizar, in vitro, uma comparação da propriedade óptica de translucidez de dois sistemas cerâmicos metal-free amplamente utilizados nos consultórios odontológicos (In-Ceram e Empress 2) comparando grupos de estudo que representassem quadros próximos às situações clínicas, produzindo amostras dos materiais estudados na espessura em que são indicados pelos fabricantes, ou seja, 0,5 mm para a infra-estrutura ou coping do In-Ceram, e 0,8 mm para a infra-estrutura do Empress 2. Foi produzido um grupo experimental com o material de Empress 2 na espessura de 0,5 mm, para ter-se um parâmetro de comparação dos dois materiais na mesma espessura. Nesta fase, todos os corpos de prova foram submetidos às leituras de translucidez, com o emprego do aparelho Jouan. Os corpos de prova foram, em uma etapa seguinte, cobertos pela cerâmica de estratificação para compararmos a situação clínica final de uma restauração indireta. Produziram-se corpos de prova com a espessura de 1,5 mm, e nova leitura da translucidez foi realizada. Esses corpos de prova receberam então o tratamento de glazeamento na face em que haviam sido cobertos com a cerâmica de estratificação, e foi realizada a última leitura da translucidez destes materiais. Os resultados, segundo a metodologia empregada, mostraram que, o Sistema Empress 2 apresenta índices translucidez superiores ao In-Ceram. Quando comparados os materiais de... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: All-ceramic systems are indirect restoring materials with excellent optical, mechanical and biological properties. The use of those materials have a fundamental clinical relevance nowadays, since the patients expectations for best esthetical results are increasing. Deep knowledge of these materials properties is very important to odontology area evolution. The objective of this work was to make an in vitro comparison on translucency optical property of two all-ceramic systems often used at dental offices (In-Ceram and Empress 2) when searching for excellence on esthetical results. This work tried to compare studying groups that represented characteristics approximate to clinical situations, producing samples of studied materials at thickness recommended by manufacturer's, that is, 0,5 mm for the core materials or coping of In-Ceram, and 0,8 mm for the Empress 2. It was produced an experimental group with the Empress 2 material at thickness of 0,5 mm, in order to provide a comparison parameter for both materials at the same thickness. At this phase, all the disc specimens were submitted to quantitative measurement of translucency, using Jouan equipment. In the next phase, the disc specimens were veneered with stratification ceramic so we could compare the final clinical situation of an indirect restoration. Disc specimens were produced with thickness of 1,5 mm, and a new measurement of translucency was made. These samples then received a glazing cycle on the side that were veneered with stratification ceramic, and finally we made the last measurement of translucency on these materials. The results, according to adopted methodology, showed that the Empress 2 System presents greater translucency than In-Ceram System. When the core materials were compared, one can establishes that: translucency index of Empress 2 (0,5 mm) > Empress 2 (0,8 mm)... (Complete abstract, click electronic address below)
Orientador: Osmir Batista de Oliveira Júnior
Coorientador: Vanderlei Salvador Bagnato
Banca: José Roberto Cury Saad
Banca: Luis Anselmo Mariotto
Mestre
APA, Harvard, Vancouver, ISO, and other styles
30

Salgado, Vinícius Esteves. "Influência da formulação e translucidez na estabilidade de cor e eficiência de polimerização de compósitos odontológicos." Universidade Federal de Pelotas, 2016. http://repositorio.ufpel.edu.br:8080/handle/prefix/3569.

Full text
Abstract:
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-21T13:55:48Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência da formulação e translucidez na estabilidade de cor e eficiência de.pdf: 1165017 bytes, checksum: 779397a9ef1b2fbad08ba861a1f39ee1 (MD5)
Made available in DSpace on 2017-06-21T13:55:48Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência da formulação e translucidez na estabilidade de cor e eficiência de.pdf: 1165017 bytes, checksum: 779397a9ef1b2fbad08ba861a1f39ee1 (MD5) Previous issue date: 2016-06-23
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
O objetivo deste estudo, dividido em duas etapas, foi investigar a influência da composição e da translucidez de compósitos odontológicos na estabilidade de cor e eficiência de polimerização. A primeira etapa envolveu a formulação de compósitos experimentais com a proposição de determinar a relação entre o sistema fotoiniciador e o conteúdo inorgânico sobre a estabilidade de cor e a eficiência de polimerização. Três sistemas fotoiniciadores foram empregados (canforquinona/amina – CQ/amina; óxido mono-alquil fosfínico - TPO e óxido bis-alquil fosfínico - BAPO) e dois tamanhos médios de partículas de sílica como carga (7nm ou 16nm). A eficiência de polimerização foi analisada pela dureza Knoop a 25kgf/mm2 por 15s utilizando microdurômetro. A estabilidade de cor foi calculada pela fórmula de diferença de cor CIELAB, mensurada com espectrofotômetro. Os materiais foram submetidos ao envelhecimento pela imersão em água e em solução de café. Os dados foram submetidos à Análise de Variância, seguidos pelo teste de Student-Newman-Keuls (a=0,05). Os materiais formulados com TPO apresentaram maior estabilidade de cor. O tamanho da partícula não influenciou os resultados da estabilidade de cor. A eficiência de polimerização não foi influenciada pelo sistema fotoiniciador ou pelo tamanho da partícula de carga. A segunda etapa deste projeto envolveu a avaliação de quatro compósitos comerciais (IPS Empress Direct, Estelite S Quick, Filtek Z350 XT e Opallis), com diferentes níveis de translucidez, com a proposição de verificar a relação entre o nível de translucidez e a estabilidade de cor, assim como entre o nível de translucidez e a eficiência de polimerização. A eficiência de polimerização foi analisada pelo grau de conversão de C=C utilizando espectroscopia no infravermelho transformada de Fourier, enquanto a estabilidade de cor foi avaliada pela fórmula de diferença de cor CIEDE2000. Os dados foram submetidos à Análise de Variância e teste de Student-Newman-Keuls (a=0,05). Foi observado que quanto maior a translucidez, menor a estabilidade de cor dos compósitos odontológicos, apesar de não ter sido observada diferença significativa em relação à eficiência de polimerização. De acordo com os resultados dos estudos pode ser concluído que o sistema fotoiniciador, o tamanho das partículas de carga e a translucidez afetaram a estabilidade de cor dos compósitos odontológicos apesar de não ter sido observada influência destes sobre a eficiência de polimerização.
The objective of this study, separated in two phases, was to investigate the process related to resin-based composites’ formulation and translucency over the color stability and cure efficiency. The first phase involved experimental resin-based composite formulations with the purpose to determine the relationship between the photoinitiator system and inorganic content over the color stability and cure efficiency. Three different photoinitiator systems were used (camphorquinone/amine – CQ/amine, monoalquil oxide – TPO, and bisalquil oxide – BAPO) and two average silica nanofiller sizes (7 nm or 16 nm). The cure efficiency was analyzed by Knoop hardness reading under 25kgf/mm² for 15s using a microindenter. The color stability was measured by CIELAB color difference formula measured with a spectrophotometer. The materials were aged by immersion in water and coffee solution. Data were submitted to Analysis of Variance followed by Student-Newman-Keuls’ test (a=0.05). TPO-based materials presented the higher color stability. The filler size did not influence the color stability results. The cure efficiency was not influenced by photoinitiator system or filler size. The second phase involved four commercial resin-based composites (IPS Empress Direct, Estelite S Quick, Filtek Z350 XT and Opallis) tested in different translucent degrees with the purpose to determine the relationship between translucency and color stability and between translucency and cure efficiency. The cure efficiency was analyzed by degree of C=C conversion using Fourier-transformed infrared spectroscopy. The color stability was measured by CIEDE2000 color difference formula. Data were submitted to Analysis of Variance and Student-Newman-Keuls’ test (a=0.05). It was observed that the higher the translucency, the lower the color stability, despite no significant difference in cure efficiency results. Based on the results from both studies, it can be concluded that the photoinitiator system, filler-particle size and translucency affect the color stability of resin-based composites although no significant influence on the cure efficiency was observed.
APA, Harvard, Vancouver, ISO, and other styles
31

Leal, Clara Lemos Nunes. "Efeito da translucidez da pastilha cerâmica na sorção de água e solubilidade de diferentes agentes de cimentação." Escola de Medicina e Saúde Pública, 2013. http://www7.bahiana.edu.br//jspui/handle/bahiana/87.

Full text
Abstract:
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2015-04-14T22:24:13Z No. of bitstreams: 1 CLARA LEMOS NUNES LEAL.pdf: 3268070 bytes, checksum: 969c5dadb96951cfa703f1cd3286cb2d (MD5)
Made available in DSpace on 2015-04-14T22:24:13Z (GMT). No. of bitstreams: 1 CLARA LEMOS NUNES LEAL.pdf: 3268070 bytes, checksum: 969c5dadb96951cfa703f1cd3286cb2d (MD5) Previous issue date: 2013
Os novos padrões de beleza tornam o sorriso um dos fatores fundamentais de convívio social. Nesse sentido, a Odontologia estética vem utilizando cada vez mais os laminados cerâmicos, que possibilitam resultados satisfatórios com mínimo desgaste dental. O objetivo deste trabalho é realizar uma revisão de literatura sobre laminados cerâmicos, suas indicações, uso, além da cimentação adesiva. Diante da literatura revisada, observou-se que a escolha da cerâmica deve ser realizada de maneira criteriosa, sendo as de dissilicato de lítio mais comumente indicadas atualmente. Verifica-se também a necessidade da realização de preparos cuidadosos, ângulos arredondados, em espessuras que variem de acordo com as necessidades individuais, especialmente pela possível interferência da cor do substrato dentário sobre o resultado final. Finalmente, dada a íntima relação entre a fixação adesiva e a durabilidade dos laminados cerâmicos, ressalta-se o cuidado necessário na escolha e aplicação dos agentes de cimentação resinosa, sua polimerização adequada, bem como preparo da superfície cerâmica e da estrutura dental, o que possibilita, de acordo com estudos, melhoria nas propriedades mecânicas desse conjunto.
APA, Harvard, Vancouver, ISO, and other styles
32

Sakamoto, Junior Antonio Setsuo. "INFLUÊNCIA DE DIFERENTES TRANSLUCIDEZ DAS CERÂMICAS SOBRE O GRAU DE CONVERSÃO E MICRODUREZA DE UM CIMENTO RESINOSO DUAL." UNIVERSIDADE ESTADUAL DE PONTA GROSSA, 2012. http://tede2.uepg.br/jspui/handle/prefix/1792.

Full text
Abstract:
Made available in DSpace on 2017-07-24T19:22:20Z (GMT). No. of bitstreams: 1 Antonio S Sakamoto Jr.pdf: 1530054 bytes, checksum: 0cc1d22fb0f1bb5e13c6f006184f113e (MD5) Previous issue date: 2012-02-24
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
The proposition of this study was to evaluate the influence of different ceramic translucency on the degree of conversion and Knoop microhardness of dual resin cement. It was made 150 samples of the resin cement dual cured Variolink II (shade A3; 5 mm in diameter and 1 mm thick) were created with interposing ceramic discs with 8 mm in diameter and 1.5 mm thick varying translucency (IPS e.max HT, HO, ZirPress HT and IPS d.SIGN). The control group was created without the interposition of ceramics. The experimental groups were photoactivated in three different times: 20, 40 and 60 seconds. 75 specimens were measured by Fourier transformed infrared spectroscopy (FTIR) to assess the degree of conversion (%). Another 75 specimens were used for the microhardness test, previously they were ground under water irrigation with grit silicon carbide granulation 320, 400, 600, 1000, 1200, finishing them with felt cloth and diamond paste with grain 1 and ¼ micrometers. Each sample was divided into four quadrants and conducted an indentation in each quadrant and then was calculated the average of these indentations. The values of the degree of conversion and Knoop hardness were analized by two-way ANOVA (type of ceramic and time of photoactivation), Bonferroni’s multiple comparison tests with a significance level of 5% and the Spearman correlation. The degree of conversion values of ceramic with high translucency were similar to the control group, the HO group presented the lowest conversion values, however when the curing time has tripled from 20 to 60 seconds, the values increased 63.9%. Translucent ceramic without infrastructure (IPS d.SIGN) presented higher microhardness values than ceramics with lithium disilicate infrastructure-based (e.max HT and HO). The negative effects of increased opacity of the ceramic on the dual resin cement can be avoided with increased time of photoactivation.
A proposição deste trabalho foi avaliar a influência de cerâmicas de diferentes translucidez sobre o grau de conversão (GC) e microdureza Knoop de um cimento resinoso dual. Foram confeccionados 150 corpos de prova do cimento resinoso dual Variolink II (cor A3; 5 mm de diâmetro e 1 mm de espessura) interpondo discos cerâmicos com 8 mm de diâmetro e 1,5 mm de espessura variando-se a translucidez da cerâmica (IPS e.max HT, HO, ZirPress HT e IPS d.SIGN). O grupo controle foi confeccionado sem interposição da cerâmica. Os grupos experimentais foram fotoativados em 3 diferentes tempos: 20, 40 e 60 segundos. Para o grau de conversão (%) foram utilizados 75 corpos de provas, onde foram mensurados através da Espectroscopia por infra vermelho por transformação de Fourier (FTIR). Para o teste de microdureza foram usados 75 corpos de prova, onde estes foram lixados sob irrigação de água com lixas de carbeto de silício de granulação 320, 400, 600, 1000, 1200, finalizando-os com pano de feltro e pasta diamantada com granulação de 1 e ¼ μm. Cada corpo de prova foi divido em 4 quadrantes erealizado uma indentação em cada quadrante e em seguida foi calculado a média destas indentações. Os valores do grau de conversão e de microdureza Knoop foram submetidos à análise de variância de dois fatores (tipo de cerâmica e tempo), pós-teste de Bonferroni com nível de significância de 5% e à correlação de Spearman. Os valores de GC para as cerâmicas de alta translucidez foram semelhantes ao grupo controle, o grupo HO apresentaram os menores valores de GC, porém obteve um aumento de 63,9% quando o tempo de fotoativação foi triplicado de 20 para 60 segundos. Já os valores de microdureza superficial foram maiores para as cerâmicas com maior translucidez sem infraestrutura (IPS d.SIGN), as cerâmicas com infraestrutura à base de dissilicato de lítio (e.max HT e HO). Os efeitos negativos da maior opacidade da cerâmica sobre o cimento resinoso dual podem ser evitados com aumento no tempo de fotoativação.
APA, Harvard, Vancouver, ISO, and other styles
33

Tostes, Bernardo Vianna. "Influência da espessura e translucidez da cerâmica de dissilicato de lítio na alteração da cor final da restauração." Universidade Federal de Juiz de Fora (UFJF), 2018. https://repositorio.ufjf.br/jspui/handle/ufjf/8066.

Full text
Abstract:
Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-11-22T11:29:10Z No. of bitstreams: 1 bernardoviannatostes.pdf: 1202505 bytes, checksum: 279cd401a93b9862d91f151677918fe8 (MD5)
Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-11-23T12:57:24Z (GMT) No. of bitstreams: 1 bernardoviannatostes.pdf: 1202505 bytes, checksum: 279cd401a93b9862d91f151677918fe8 (MD5)
Made available in DSpace on 2018-11-23T12:57:24Z (GMT). No. of bitstreams: 1 bernardoviannatostes.pdf: 1202505 bytes, checksum: 279cd401a93b9862d91f151677918fe8 (MD5) Previous issue date: 2018-08-20
O objetivo deste trabalho foi avaliar a influência da espessura e translucidez da cerâmica de dissilicato de lítio na capacidade de mascarar um substrato escurecido. Um total de 120 espécimes foram confeccionados, contendo, laminados cerâmicos na cor A1, de IPS e.max Press LT, (Ivoclar Vivadent AG), IPS e.max Press HT, (Ivoclar Vivadent AG) e IPS e.max Press Impulse Value 1, (Ivoclar Vivadent AG) com quatro espessuras diferentes (0,3; 0,5; 0,7 e 1mm), cimentados com cimento resinoso Variolink Veneer, de cor neutra. As coordenadas e as diferenças de cor CIELAB foram calculadas usando um espectrofotômetro. O ΔE (diferença de cor) foi obtido comparando um espécime controle (IPS e.max Press, LT A1 (Ivoclar Vivadent AG) com espessura de 2mm, chamado de baseline com os grupos de estudo. Os dados foram submetidos à análise de variância a dois critérios. Na sequência, para as comparações múltiplas, empregou-se o teste de Tukey. Os cálculos estatísticos foram realizados no programa SPSS 23 (SPSS Inc., Chicago, IL, EUA) adotando-se o nível de significância de 5%. Se considerado o limiar a partir do qual clinicamente seria percebida a alteração de cor (ΔE = 3,3), somente na espessura de 1,0 mm todas as cerâmicas possuíram valores de ΔE abaixo do limiar de 3,3. Utilizando-se pastilhas com 0,7 e 0,5 mm, o mascaramento foi possível apenas com as cerâmicas de baixa translucidez e do tipo Impulse. HJá com 0,3 mm, nenhuma das cerâmicas testadas revelou valores de ΔE inferiores ao limiar de alteração de cor clinicamente perceptível (p =.006). A capacidade de mascarar um substrato escuro foi significativamente influenciada pela espessura da cerâmica e pelo seu grau de translucidez. Cerâmicas mais espessas possuem maior capacidade de mascarar a cor do substrato. Cerâmicas ultrafinas, 0,3mm, são inviáveis como opção terapêutica para casos clínicos que necessitem de alteração de cor. Cerâmicas mais opacas ou com caráter opalescentes apresentaram melhores capacidade de mascaramento de substrato escuro.
The aim of this study was evaluate the influence of thickness and translucency of lithium disilicate ceramic on the capability of masking a discolored tooths. A total of 120 specimens were prepared containing A1-color ceramic laminates of IPS e.max Press LT (Ivoclar Vivadent AG), IPS e.max Press, HT (Ivoclar Vivadent AG), and IPS e.max Press Impulse Value 1 (Ivoclar Vivadent AG) with four different thicknesses (0.3 mm, 0.5 mm, 0.7 mm, and 1 mm), cemented with Variolink Veneer resin cement of neutral color. CIELAB coordinates and color differences were calculated using a spectrophotometer. ΔE (color difference) was assessed by comparing a control specimen (IPS e.max Press, LT A1, [Ivoclar Vivadent AG]) with a thickness of 2 mm, called baseline, in the study groups. Data were subjected to the two-way analysis of variance. Subsequently, the Tukey test was used for multiple comparisons. Considering the threshold of a clinically perceived color change (ΔE = 3.3), the ceramics would have ΔE values below the threshold of 3.3 with the thickness of 1.0 mm, regardless of the ceramic used. Masking was possible only with low translucency and Impulse ceramics using 0.7- and 0.5-mm chips. None of the ceramics assessed showed ΔE values below the threshold of clinically perceptible color change at 0.3 mm (p = .006). Ultra-thin ceramics are not feasible as a therapeutic option for clinical cases that require color change. More opaque or opalescent ceramics showed better capability of dark substrate masking.
APA, Harvard, Vancouver, ISO, and other styles
34

Rodrigues, Neto Elidio. "Avaliação da influência do selante de superfície sobre a translucidez de resina composta. Efeito de tempos e soluções /." Araraquara : [s.n.], 2004. http://hdl.handle.net/11449/89654.

Full text
Abstract:
Resumo: O presente trabalho teve como objetivo avaliar o efeito do selante de superfície sobre a translucidez da resina composta, em função das soluções e do tempo de imersão. Para isso foram selecionados os seguintes materiais: resina composta Charisma; selante de superfície Fortify; e quatro soluções para imersão, café, Coca-Cola®, chá e Saliva Artificial. Foram confeccionados 8 corpos-de-prova para cada condição experimental, totalizando 64 corpos-de-prova. A partir disso, os mesmos permaneceram imersos em saliva artificial, mantidos em estufa a uma temperatura de 37ºCl 1, e foram retirados da estufa para imersão nas soluções testadas, três vezes ao dia por um período de cinco minutos, e após este período foram lavados em água corrente e novamente imersos em saliva artificial, até o momento determinado para a leitura da translucidez. As leituras foram realizadas em nove níveis: T1 - após a confecção dos corpos-de-prova, T2 - 24 horas após a imersão nas soluções, T3 - 48 horas após, T4 a T9, sendo respectivamente 7, 14, 21, 30, 60 e 90 dias após a imersão. Para a obtenção dos valores de translucidez (em porcentagem) foi utilizado o aparelho "JOUAN". Os resultados obtidos foram submetidos à Análise de Variância e ao Teste de Tukey a 5%. Observou-se que as soluções influenciaram na translucidez dos materiais (p<0,001), sendo que o café apresentou maior ação pigmentante, seguido pelo chá, Coca-Cola® e saliva artificial. Com relação ao tempo notou-se que a partir de T5 houve uma significante alteração (p<0,001) na translucidez da resina até T8. E quanto ao selante o grupo selado apresentou maiores valores de translucidez (p<0,05) do que o grupo não selado. Mediante a metodologia aplicada pode-se concluir que o café foi a solução que promoveu maior alteração de translucidez, a resina composta sofreu alteração significativa... (Resumo completo, clicar acesso eletrônico abaixo).
Abstract: The aim of the current study was to evaluate the surface sealant effect upon the composite resin translucence, related to different solutions and immersion periods. The following materials were selected: Charisma composite resin; Fortify surface sealant; and four immersion solutions, which are coffee, Coca-Cola®, tea and Artificial Saliva. Eight test specimens were manufactured for each experimental condition, totaling 64 test specimens. All the specimens were immersed in artificial saliva and maintained in a kiln at 37ºCl 1, being then removed for a five-minute immersion period three times a day in the solutions tested, after which they were washed with tap water and immersed in artificial saliva once more until the translucence reading was performed. The readings were performed in nine levels: T1 - after test specimens manufacture, T2 - 24 hours after the immersion in the solutions, T3 - 48 hours after the immersion, T4 to T9, respectively 7, 14, 21, 30, 60 and 90 days after the immersion. In order to achieve translucence scores (in percentage), the appliance "JOUAN" was used. The results obtained were submitted to the Analysis of Variance and to Tukey's test at 5%. It was possible to observe that the solutions influenced on the materials translucence (p<0.001), and that coffee showed the most staining action, followed by tea, Coca-Cola® and artificial saliva. In regard to time, a significant alteration (p<0.001) was noticed in the composite resin from T5 up to T8. Considering the sealant, the sealed group showed higher scores of translucence (p<0.05) than the non-sealed group. According to the methodology applied, it is possible to conclude that coffee was the solution which provided the most intense translucence alteration, the composite resin underwent a significant alteration in translucence after 21 days of... (Complete abstract, click electronic address below).
Orientador: Patrícia Petromilli Nordi Sasso Garcia
Banca: Welingtom Dinelli
Banca: Silmara Aparecida Milori Corona
Coorientador: Regina Guenka Palma Dibb
Mestre
APA, Harvard, Vancouver, ISO, and other styles
35

Souayfane, Farah. "Modèle simplifié de changement de phase en présence de convection et rayonnement : application à un mur translucide associant superisolation et stockage d'énergie thermiques." Thesis, Université Côte d'Azur (ComUE), 2018. http://www.theses.fr/2018AZUR4043/document.

Full text
Abstract:
Cette thèse vise à étudier l'exploitation du rayonnement solaire grâce à un nouveau concept de mur capteur passif. Dans ce contexte, le comportement thermique d’un mur solaire semi-transparent a été étudié. Le mur fournit un éclairage naturel et est composé d’une couche d’aérogel de silice assurant une isolation thermique et acoustique, et d’un MCP. Ce dernier est contenu dans des briques de verre assurant l’absorption, le stockage et la restitution de chaleur. Ce mur a été caractérisé expérimentalement au centre PERSEE à Sophia. Il a été remarqué que la performance thermique du mur est élevée en hiver, tandis qu’une surchauffe estivale a été rencontrée. Un modèle numérique simplifié a été développé pour modéliser la convection naturelle et le rayonnement pendant la fusion du MCP. Ce modèle est validé à l’aide d’un modèle CFD, et des résultats de Benchmark. Pour optimiser la performance du mur en été, un modèle numérique du transfert de chaleur à travers le mur a été développé sous MATLAB. Ce modèle a été couplé à TRNSYS afin d’évaluer la performance thermique de l'ensemble du bâtiment. Le modèle couplé a été validé expérimentalement. Le comportement thermique du mur est testé dans des différents climats, et des solutions passives sont proposées pour assurer le confort thermique. Enfin, ce modèle a permis d'étudier le comportement thermique annuel d’un bâtiment intégrant un mur MCP- aérogel dans son enveloppe et une étude économique a été réalisée. Ces études ont confirmé l'intérêt du mur vis-à-vis de l'amélioration des performances énergétiques du bâtiment. La faisabilité économique de l'application du mur dépend du climat, du coût d’énergie, et du coût d'investissement
This thesis aims to study the exploitation of solar radiation thanks to a new concept of passive sensor wall. In this context, the thermal behavior of a novel semi-transparent solar wall has been studied. The wall is composed of glazing, silica aerogel (TIM) and glass bricks filled with fatty acids (PCM). This wall provides storage and restitution of heat, thermal-acoustic insulation and daylighting. The thermal performance of the TIM-PCM wall is tested in a full-sized test cell located in Sophia, PERSEE center. In winter, particularly in sunny cold days, the PCM absorbs solar radiation, melts, and then releases the stored heat to the building at night. During summer, overheating is encountered, the PCM remains in its liquid state and is unable to release the stored heat. A simplified model for PCM melting in presence of natural convection and radiation is developed and validated using a CFD model, and benchmark solutions. Then, a numerical model describing the heat transfer mechanisms through the wall is developed. This model is linked to TRNSYS to assess the thermal performance of the whole building. The MATLAB-TRNSYS model is then validated experimentally. The thermal behavior of the wall is tested under different climates, and passive solutions are proposed to ensure thermal comfort in summer. Finally, the validated model is used to study the annual thermal behavior of a building integrating TIM-PCM wall and an economic study is conducted. These studies confirm the interest of the wall vis-à-vis the improvement of energy performance of the building. The economic feasibility of applying the TIM-PCM wall depends mainly on climate, energy costs, and investment cost
APA, Harvard, Vancouver, ISO, and other styles
36

Pinto, Marcelo Mendes. "Propriedades ópticas e microestrutura de materiais cerâmicos de restauração dentária." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/23/23140/tde-04032010-082652/.

Full text
Abstract:
O objetivo do trabalho foi o de avançar na compreensão dos mecanismos envolvidos no comportamento óptico de diferentes materiais cerâmicos em função da espessura, utilizados para restauração dentária, determinar os coeficientes de absorção e espalhamento e correlacioná-los às características microestruturais de cada material. Além disso, foi avaliada a capacidade de mascaramento e a razão de contraste do material cerâmico nas formas monolítica, em duas camadas e como restauração cimentada. Para tanto, foram analisadas quatro cerâmicas odontológicas, uma porcelana de cobertura (vítrea) e três compósitos cerâmicos infiltrados com vidro do Sistema InCeram (alumina/vidro, alumina/zircônia/vidro e espinélio/vidro), além de uma resina composta odontológica empregada como substrato resinoso e um cimento resinoso para cimentação. Os coeficientes de espalhamento e absorção foram determinados por meio dos modelos de Beer-Lambert e Kubelka-Munk a partir das curvas espectrais de transmitância e reflectância (com fundos branco e preto) geradas em um espectrofotômetro na faixa de comprimento de onda entre 300 e 800 nm. A microestrutura de cada material foi analisada por meio de microscopia eletrônica de varredura com mapeamento elementar, difração de raios X e análise química por fluorescênica de raios X. O comportamento óptico dos materiais estudados foi influenciado pelas características microestruturais do material e a pela espessura. Os valores do coeficiente de espalhamento, S, das cerâmicas avaliadas foram significativamente maiores do que os valores do coeficiente de absorção, K, na região do visível. Foram propostas equações para prever as curvas espectrais de reflectância e transmitância de bilayers e de restaurações cimentadas.
The aim of this work was to advance in the understanding of the mechanisms related to the optical behavior of different ceramic materials as a function of thickness, used for dental restoration, to determine the absorption and scattering coefficients and to correlate them to the microstructural characteristics of each material. The masking ability and the contrast ratio of ceramic material as monolith, bilayer and cemented restoration were also evaluated. For this, four dental ceramics, one porcelain and three glass-infiltrated ceramic composites of InCeram System (alumina/glass, alumina/zirconia/glass, and spinell/glass), besides one dental composite resin used as resinous substrate and one resinous cement for luting. The scattering and absorption coefficients were determined by the Beer-Lambert and Kubelka-Munk models using spectral curves of transmittance and reflectance (with white and black backs) generated in a spectrophotometer in the 300 to 800 nm wavelength range. The microstructure of each material was analyzed by scanning electron microscopy with elemental mapping, X-ray diffraction, and chemical analysis by X-ray fluorescence. The optical behavior of studied materials was affected by the microstructural characteristics and thickness of the material. The values of scattering coefficient, S, of evaluated ceramics were significantly higher than the values of absorption coefficient, K, in the visible range. Equations for the prediction of reflectance and transmittance spectral curves of bilayer and cemented restorations were proposed.
APA, Harvard, Vancouver, ISO, and other styles
37

Takeuchi, Cristina Yoshie Garcia [UNESP]. "Avaliação do efeito da fumaça do cigarro na translucidez da resina composta: influência do selante da superfície e da escovação." Universidade Estadual Paulista (UNESP), 2004. http://hdl.handle.net/11449/89645.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-09Bitstream added on 2014-06-13T19:10:19Z : No. of bitstreams: 1 takeuchi_cyg_me_arafo.pdf: 548399 bytes, checksum: dc80caffca8640c92d69a902fa0d9a40 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O objetivo deste estudo foi avaliar in vitro a translucidez da resina composta, em função do efeito do selamento superficial; da exposição à fumaça de cigarro e da escovação. Para tanto, 40 corpos-de-prova (10 mm X 1 mm) foram confeccionados com resina composta Filtek Z250 divididos aleatoriamente em 4 grupos (n=10), sendo: G1 - controle (saliva artificial e sem selante); G2 - saliva artificial e com selante (Protect-it!); G3 - cigarro e sem selante e G4 - cigarro e com selante. Os espécimes foram submetidos à avaliação da translucidez em diferentes tempos: T1: imediatamente após a confecção; T2: após o polimento; T3: após o selamento (G2 e G4); T4: após o 1º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T5: após serem submetidos a 1ª escovação (850 ciclos); T6: após o 2º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T7: após serem submetidos a 2ª escovação (850 ciclos); T8: após o 3º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T9: após serem submetidos a 3ª escovação (850 ciclos). Os valores de translucidez foram obtidos no aparelho JOUAN e analisados estatisticamente pelos testes de Mann-Whitney, Kruskal-Wallis, Friedman, seguidos da Análise de Variância e teste de Tukey. Observou-se que o selamento não provocou alteração significativa da translucidez dos espécimes e que após a 1ª escovação ocorreu aumento significativo, mantendo-se constante nos G1 e G2, e para os G3 e G4 o cigarro provocou severo manchamento que foi removido parcialmente pela escovação. Concluindo que o selamento não promoveu melhora na translucidez com o tempo e nem protegeu contra manchamento, sendo que a escovação não restabeleceu a translucidez.
The aim of this study was to assess in vitro the translucency of the composite resin, in function of the effect of the surface sealing; after the exposition to the cigarette smoke and of the toothbrushing. Forty specimens (10mm X 1mm) they were made with composite resin Filtek Z250 divided into 4 groups (n = 10), being: G1 - it controls (it artificial saliva and without sealant); G2 - it artificial saliva and with sealant (Protect-it!); G3 - cigarette and without sealant and G4 - cigarette and with sealant. The specimens were submitted to the evaluation of the translucency in different times: T1: immediately after the making; T2: after the polishing; T3: after the sealing (G2 and G4); T4: after the 1st treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T5: after they be submitted to 1st toothbrushing (850 cycles); T6: after the 2nd treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T7: after they be submitted to 2nd toothbrushing (850 cycles); T8: after the 3rd treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T9: after they be submitted to 3rd toothbrushing (850 cycles). The translucency values were obtained in the JOUAN apparel and analyzed by the tests of Mann-Whitney, Kruskal-Wallis and Friedman, following by the Analysis of Variance and test of Tukey. It was observed that the sealing didn't provoke significant alteration of the translucency of the specimens and that after to 1st toothbrushing it happened significant increase, staying constant in G1 and G2, and for G3 and G4 the cigarette provoked severe staining that was removed partially by the toothbrushing. Concluding that the sealing didn't promote improvement in the translucency with the time and nor it protected against staining, and the toothbrushing didn’t reestablish the translucency.
APA, Harvard, Vancouver, ISO, and other styles
38

Takeuchi, Cristina Yoshie Garcia. "Avaliação do efeito da fumaça do cigarro na translucidez da resina composta : influência do selante da superfície e da escovação /." Araraquara : [s.n.], 2004. http://hdl.handle.net/11449/89645.

Full text
Abstract:
Orientador: Welingtom Dinelli
Banca: José Roberto Cury Saad
Banca: Regina Guenka Palma Dibb
Resumo: O objetivo deste estudo foi avaliar in vitro a translucidez da resina composta, em função do efeito do selamento superficial; da exposição à fumaça de cigarro e da escovação. Para tanto, 40 corpos-de-prova (10 mm X 1 mm) foram confeccionados com resina composta Filtek Z250 divididos aleatoriamente em 4 grupos (n=10), sendo: G1 - controle (saliva artificial e sem selante); G2 - saliva artificial e com selante (Protect-it!); G3 - cigarro e sem selante e G4 - cigarro e com selante. Os espécimes foram submetidos à avaliação da translucidez em diferentes tempos: T1: imediatamente após a confecção; T2: após o polimento; T3: após o selamento (G2 e G4); T4: após o 1º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T5: após serem submetidos a 1ª escovação (850 ciclos); T6: após o 2º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T7: após serem submetidos a 2ª escovação (850 ciclos); T8: após o 3º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T9: após serem submetidos a 3ª escovação (850 ciclos). Os valores de translucidez foram obtidos no aparelho JOUAN e analisados estatisticamente pelos testes de Mann-Whitney, Kruskal-Wallis, Friedman, seguidos da Análise de Variância e teste de Tukey. Observou-se que o selamento não provocou alteração significativa da translucidez dos espécimes e que após a 1ª escovação ocorreu aumento significativo, mantendo-se constante nos G1 e G2, e para os G3 e G4 o cigarro provocou severo manchamento que foi removido parcialmente pela escovação. Concluindo que o selamento não promoveu melhora na translucidez com o tempo e nem protegeu contra manchamento, sendo que a escovação não restabeleceu a translucidez.
Abstract: The aim of this study was to assess in vitro the translucency of the composite resin, in function of the effect of the surface sealing; after the exposition to the cigarette smoke and of the toothbrushing. Forty specimens (10mm X 1mm) they were made with composite resin Filtek Z250 divided into 4 groups (n = 10), being: G1 - it controls (it artificial saliva and without sealant); G2 - it artificial saliva and with sealant (Protect-it!); G3 - cigarette and without sealant and G4 - cigarette and with sealant. The specimens were submitted to the evaluation of the translucency in different times: T1: immediately after the making; T2: after the polishing; T3: after the sealing (G2 and G4); T4: after the 1st treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T5: after they be submitted to 1st toothbrushing (850 cycles); T6: after the 2nd treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T7: after they be submitted to 2nd toothbrushing (850 cycles); T8: after the 3rd treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T9: after they be submitted to 3rd toothbrushing (850 cycles). The translucency values were obtained in the JOUAN apparel and analyzed by the tests of Mann-Whitney, Kruskal-Wallis and Friedman, following by the Analysis of Variance and test of Tukey. It was observed that the sealing didn't provoke significant alteration of the translucency of the specimens and that after to 1st toothbrushing it happened significant increase, staying constant in G1 and G2, and for G3 and G4 the cigarette provoked severe staining that was removed partially by the toothbrushing. Concluding that the sealing didn't promote improvement in the translucency with the time and nor it protected against staining, and the toothbrushing didn't reestablish the translucency.
Mestre
APA, Harvard, Vancouver, ISO, and other styles
39

Anstotz, Freddy. "Etude d'un capteur électro-optique pour la détection et la classification temps réel de défauts dans des panneaux alvéolaires translucides." Mulhouse, 1991. http://www.theses.fr/1991MULH0203.

Full text
Abstract:
Cette étude concerne le contrôle non destructif de panneaux alvéolaires translucides. Les caractéristiques optiques des panneaux (transparence, striures. . . ) ainsi que la nature des défauts (taches, rayures. . . ) nous ont conduit à étudier un capteur optoélectronique composé d'une source laser et d'un système optique réalisant la transformée de Fourier (spectre de diffraction) de la surface du panneau au plan focale du système. Une matrice de photo-détecteurs permet l'échantillonnage spatial du spectre et l'obtention d'un vecteur de mesures caractérisant la surface du produit inspecté. La détection et la reconnaissance des vecteurs de mesures se font à l'aide d'algorithmes de classification implémentés sur calculateur. L'analyse du spectre de diffraction en fonction des différents types de défauts nous a conduit à proposer une première méthode de détection en mesurant l'intensité globale et la déformation du spectre de diffraction. Les défauts sont détectés par simple seuillage de ces deux paramètres lors du balayage des panneaux. Cette méthode simple permet la détection de trois types de défauts. Une seconde méthode consistant à extraire 16 caractéristiques spectrales nous a conduit à l'optimisation du montage optique. L'analyse en composantes principales (ACP) des mesures a permis de déterminer les paramètres optimaux du système optique afin de garantir une classification correcte des mesures. Enfin nous proposons différentes stratégies de détection et de reconnaissance des défauts permettant de traiter les informations en temps réel. Pour cela nous avons utilisé d'une part, des algorithmes classiques de reconnaissance des signaux (mesure de vraisemblance, Foley-Sammon. . . ). D'autre part, nous avons mis en oeuvre des réseaux de neurones permettant également la classification des défauts. Cette seconde méthode permet la détection de cinq types de défauts par analyse alvéole par alvéole de la surface des panneaux
APA, Harvard, Vancouver, ISO, and other styles
40

Hilgert, Leandro Augusto. "Influência da coloração do substrato, espessura e translucidez da cerâmica na cor de facetas laminadas produzidas com o sistema CEREC inLab." Florianópolis, SC, 2009. http://repositorio.ufsc.br/xmlui/handle/123456789/92449.

Full text
Abstract:
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia.
Made available in DSpace on 2012-10-24T08:59:38Z (GMT). No. of bitstreams: 1 268353.pdf: 3288334 bytes, checksum: ff1e19404dfabc735e020224a39b7578 (MD5)
O objetivo deste estudo in vitro foi investigar, espectrofotométrica e visualmente, a cor de facetas produzidas com um sistema CAD/CAM, com diferentes níveis de descoloração de substrato, espessuras de material e graus de translucidez das cerâmicas. Para isso, incisivos centrais superiores esquerdos de um modelo dental acrílico foram preparados para facetas com 0,4, 0,7 e 1,00mm de desgaste axial. Esses foram replicados em três diferentes colorações que simulavam substratos normal, escurecido e severamente escurecido. As facetas cerâmicas foram produzidas com o sistema CEREC inLab pelo método de correlação à anatomia hígida para cada tipo de preparo, com blocos dos materiais EmpressCAD HT (HT), EmpressCAD LT (LT) e EmpressCAD Multi (MU) e e.maxCAD HT (EH). Todas as restaurações receberam caracterização extrínseca e glazeamento padronizados. A união das facetas aos preparos foi simulada com um gel try-in padrão. As diferentes combinações de profundidade e preparo, coloração do substrato e cerâmica foram estandardizadamente fotografadas e tiveram sua cor mensurada por um espectrofotômetro clínico. As coordenadas de cor (CIELAB) instrumentalmente mensuradas foram comparadas às de uma restauração-referência (preparo normal, 0,7mm de espessura e cerâmica HT), para a determinação da diferença de cor (?E). As fotografias foram analisadas por 7 avaliadores que determinaram se a diferença de cor entre espécimes e restauração-padrão era aceitável ou inaceitável. Os resultados das análises espectrofotométrica e visual permitiram estabelecer um limite de aceitabilidade de diferença de cor para o estudo igual a ?E=3,3. Substratos normais foram restaurados de maneira aceitável com preparos conservadores (0,4mm) e cerâmicas translúcidas (HT, EH e MU). Substratos escurecidos obtiveram bons resultados com 0,4mm de espessura e cerâmica LT ou 0,7mm e cerâmicas MU e LT. O escurecimento severo só foi mascarado adequadamente com espessura de 1,0mm e cerâmica LT. Cor do substrato, espessura e grau de translucidez da cerâmica afetam significativamente a cor final de facetas laminadas. Cerâmicas menos translúcidas e preparos mais invasivos colaboram no poder de mascaramento das facetas sobre substratos escurecidos.
The aim of this study was evaluating, spectrophotometric- and visually, the color of veneers fabricated by a CAD/CAM system, with different levels of stump discoloration, material thickness and translucency degrees of the ceramics. Acrylic upper-left central incisors of a dental model received veneer preparations with 0.4, 0.7 or 1.0mm of axial reduction and were reproduced in three different levels of discoloration, simulating normal, discolored and severely discolored stump shades. The ceramic veneers were produced by the CEREC inLab system using correlation mode. Milling blocks used were EmpressCAD HT (HT), EmpressCAD LT (LT), EmpressCAD Multi (MU) and e.maxCAD HT (EH). All restorations were standardly stained and glazed. Cementation was simulated with a standard try-in paste. The different combinations of preparation depth, stump shade and ceramic translucency degree were standardly photographed and analyzed by a clinical spectrophotometer. The measured CIELAB coordinates were compared to a reference-restoration (normal stump shade, 0.7mm thickness and HT ceramic) to determine de color difference (?E). The photographs were analyzed by seven observers that judged the color difference between test-specimens and reference-restoration acceptable or not. Results from instrumental and visual analysis allowed an acceptability threshold of ?E=3,3 to be determined for this study. Normal stump shades were acceptably restored with conservative preparations (0.4mm) and translucent ceramics (HT, MU and EH). Discolored stumps presented good results with 0.4mm/LT, and 0.7mm/MU or 0.7mm/LT. Severe discoloration was only masked by 1.0mm preparation and LT. Stump shade, thickness and translucency degree of the ceramic significantly affect the final color of laminate veneers. Less translucent ceramics and more invasive preparations increase the masking power of veneers on discolored substrates.
APA, Harvard, Vancouver, ISO, and other styles
41

Simonot, Lionel. "Étude expérimentale et modélisation de la diffusion de la lumière dans une couche de peinture colorée et translucide : application à l'effet visuel des glacis et des vernis." Paris 6, 2002. https://tel.archives-ouvertes.fr/tel-00002238.

Full text
APA, Harvard, Vancouver, ISO, and other styles
42

Villa, Felipe Augusto. "INFLUÊNCIA DA TRANSLUCIDEZ DE PINOS DE FIBRA DE VIDRO E TEMPO DE FOTOATIVAÇÃO DE UM CIMENTO DUAL NA RESISTÊNCIA DE UNIÃO À DENTINA RADICULAR." UNIVERSIDADE ESTADUAL DE PONTA GROSSA, 2012. http://tede2.uepg.br/jspui/handle/prefix/1794.

Full text
Abstract:
Made available in DSpace on 2017-07-24T19:22:21Z (GMT). No. of bitstreams: 1 Felipe Villa Verde.pdf: 899114 bytes, checksum: 339db35f81d16c1053ac909db81b72f5 (MD5) Previous issue date: 2012-02-27
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
The aim of this study was to evaluate in vitro through the push-out test, if the use of opaque glass fiber posts (Exacto – Angelus [PO]) and translucent (Exacto Translucent – Angelus [PT]), adhesively cemented into the root with dual resin cement (Variolink II - Ivoclar Vivadent) under different polymerization time had an influence on the bond strength in three different root canal thirds. Forty-eight singlerooted extracted human premolars were selected from the Tooth Bank UEPG for research. They had their crowns sectioned to form roots with 15 mm in length. All teeth received endodontic treatment and then were divided into 6 groups (n=8), to receive the cementation according to the type of glass fiber post (opaque vs.translucent) and the time of photoactivation of resin cement (20, 40 and 60 seconds). After storage in water at 37° C for one week, the teeth were embedded in acrylic resin and sectioned perpendicular to its long axis to form discs 1 mm thick, with two discs for each root third, and then were taken to the machine universal testing. The push-out test was performed at a speed of 0.5 mm/min. The data were statistically analyzed by ANOVA and Tukey's test (p = 0.05). The mean values of bond strength (MPa) and standard deviation (SD) for groups in the cervical third, middle and apical regions were: PO20 - 21.02 ± 3.52, 15.83 ± 4.94 and 5.20 ± 10:48; PO40 - 14.42 ± 3.98, 12.12 ± 4.40 and 11.59 ± 4.89; PO60 - 16.27 ± 7.14, 13.33 ± 5.22 and 16.99 ± 7.82; PT20 - 18.34 ± 5.47, 10.83 ± 4.63 and 9.98 ± 4.76; PT40 - 17.51 ± 6.55, 14.06 ± 3.85 and 10.95 ± 4.65; PT60 - 19.42 ± 5.86, 15.35 ± 5.43 and 12.77 ± 5.93). There were no significant differences between the types of fiber posts used and the different times of polymerization (p>0.05) in relation to the root area were statistically significant differences only between the cervical and the other thirds (p>0.05). It can be concluded that the bond strength of the root canals was not affected by the type of glass fiber post (opaque vs. translucent) and photoactivation time.
O objetivo deste estudo in vitro foi avaliar por meio do teste de push-out, se a utilização de pinos de fibra de vidro opaco (Exacto – Angelus [PO]) e translúcido (Exacto Translúcido – Angelus [PT]), cimentados adesivamente no canal radicular com cimento resinoso de presa dual (Variolink II – Ivoclar Vivadent) sob diferentes tempos de fotoativação apresentavam influência na resistência de união nos três diferentes terços do canal radicular. Quarenta e oito pré-molares unirradiculares humanos extraídos foram selecionados no Banco de Dentes da UEPG para a pesquisa. Tiveram suas coroas seccionadas para formar raízes com 15 mm de comprimento. Todos os dentes receberam tratamento endodôntico e em seguida foram divididos em 6 grupos (n=8), para receber a cimentação de acordo com o tipo de pino de fibra de vidro (opaco vs translúcido) e com o tempo de fotoativação do cimento resinoso (20, 40 e 60 segundos). Após o armazenamento em água a 37o C por uma semana, os dentes foram embutidos em resina acrílica e seccionados perpendicularmente ao seu longo eixo para formar discos de 1 mm de espessura, sendo 2 discos para cada terço radicular, e em seguida foram levados à máquina de ensaios universal. O teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Os dados obtidos foram analisados estatisticamente por meio do teste ANOVA e pós-teste de Tukey (p=0,05). Os valores médios de RU (MPa) e desvio padrão (DP) para os grupos nos terços cervical, médio e apical foram respectivamente: PO20 – 21,02 ± 3,52, 15,83 ± 4,94 e 10,48 ± 5,20; PO40 – 14,42 ± 3,98, 12,12 ± 4,40 e 11,59 ± 4,89; PO60 – 16,27 ± 7,14, 13,33 ± 5,22 e 16,99 ± 7,82; PT20 – 18,34 ± 5,47, 10,83 ± 4,63 e 9,98 ± 4,76; PT40 – 17,51 ± 6,55, 14,06 ± 3,85 e 10,95 ± 4,65; PT60 – 19,42 ± 5,86, 15,35 ± 5,43 e 12,77 ± 5,93. Não foram observadas diferenças significativas entre os tipos de pino de fibra utilizados e os diferentes tempos de fotoativação (p > 0,05); em relação à região radicular foram encontradas diferenças estatisticamente significativas somente entre o terço cervical e os demais terços (p > 0,05). Pode-se concluir que a resistência de união do canal radicular não foi afetada pelo tipo de pino de fibra de vidro (opaco vs translúcido) e tempo de fotoativação. O objetivo deste estudo in vitro foi avaliar por meio do teste de push-out, se a utilização de pinos de fibra de vidro opaco (Exacto – Angelus [PO]) e translúcido (Exacto Translúcido – Angelus [PT]), cimentados adesivamente no canal radicular com cimento resinoso de presa dual (Variolink II – Ivoclar Vivadent) sob diferentes tempos de fotoativação apresentavam influência na resistência de união nos três diferentes terços do canal radicular. Quarenta e oito pré-molares unirradiculares humanos extraídos foram selecionados no Banco de Dentes da UEPG para a pesquisa. Tiveram suas coroas seccionadas para formar raízes com 15 mm de comprimento. Todos os dentes receberam tratamento endodôntico e em seguida foram divididos em 6 grupos (n=8), para receber a cimentação de acordo com o tipo de pino de fibra de vidro (opaco vs translúcido) e com o tempo de fotoativação do cimento resinoso (20, 40 e 60 segundos). Após o armazenamento em água a 37o C por uma semana, os dentes foram embutidos em resina acrílica e seccionados perpendicularmente ao seu longo eixo para formar discos de 1 mm de espessura, sendo 2 discos para cada terço radicular, e em seguida foram levados à máquina de ensaios universal. O teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Os dados obtidos foram analisados estatisticamente por meio do teste ANOVA e pós-teste de Tukey (p=0,05). Os valores médios de RU (MPa) e desvio padrão (DP) para os grupos nos terços cervical, médio e apical foram respectivamente: PO20 – 21,02 ± 3,52, 15,83 ± 4,94 e 10,48 ± 5,20; PO40 – 14,42 ± 3,98, 12,12 ± 4,40 e 11,59 ± 4,89; PO60 – 16,27 ± 7,14, 13,33 ± 5,22 e 16,99 ± 7,82; PT20 – 18,34 ± 5,47, 10,83 ± 4,63 e 9,98 ± 4,76; PT40 – 17,51 ± 6,55, 14,06 ± 3,85 e 10,95 ± 4,65; PT60 – 19,42 ± 5,86, 15,35 ± 5,43 e 12,77 ± 5,93. Não foram observadas diferenças significativas entre os tipos de pino de fibra utilizados e os diferentes tempos de fotoativação (p > 0,05); em relação à região radicular foram encontradas diferenças estatisticamente significativas somente entre o terço cervical e os demais terços (p > 0,05). Pode-se concluir que a resistência de união do canal radicular não foi afetada pelo tipo de pino de fibra de vidro (opaco vs translúcido) e tempo de fotoativação.
APA, Harvard, Vancouver, ISO, and other styles
43

Ferreira, Ana Sofia da Costa. "Formulação de um grés porcelânico super-branco e translúcido." Master's thesis, Universidade de Aveiro, 2014. http://hdl.handle.net/10773/13964.

Full text
Abstract:
Mestrado em Engenharia de Materiais
O presente trabalho surge em parceria com a empresa Revigrés – Indústria de Revestimentos de Grés, Lda., com o objetivo de criar uma nova formulação de grés, a partir das formulações já existentes na empresa, com elevada brancura e translucidez e o aumento do rendimento da cor, mantendo as restantes propriedades mecânicas do corpo sinterizado. Para tal, estudou-se a alteração das suas composições: i) diminuir a percentagem de componentes da pasta que não cozem branco; ii) estudar o efeito de possíveis agentes branqueadores na cor e nas propriedades dos produtos cerâmicos alvo, e iii) estudar o efeito da adição de fritas cerâmicas, com o intuito de minimizar a porosidade e aumentar a densidade das pastas e, consequentemente maximizar a translucidez da pasta.
The present work is a partnership with “Revigrés - Indústria de Revestimentos de Grés, Lda.” with the aim to create a new formulation of stoneware, from the existing formulations of the company, with high whiteness and translucency and increasing the colour performance, maintaining all other mechanical properties of the sintered body. For that purpose, we studied the changes of its compositions: i) reduce the percentage of components that don´t sinter in white; ii) study the possible effects whitening agents have on the colour and properties in the ceramics, and iii) study the effect of adding ceramic frits, in order to minimize the porosity and increase the density of the sinter body and consequently maximize the translucency of the body.
APA, Harvard, Vancouver, ISO, and other styles
44

Castillo, Peña Ranulfo. "Efeito do peróxido de hidrogênio a 40% no potencial de clareamento, na susceptibilidade à pigmentação e na translucidez e brancura de materiais monolíticos CAD-CAM. /." Araraquara, 2020. http://hdl.handle.net/11449/191879.

Full text
Abstract:
Orientador: Renata Garcia Fonseca
Resumo: Como as propriedades ópticas de materiais monolíticos CAD-CAM se comportam diante do clareamento necessita de investigação para orientar o cirurgião-dentista sobre se deve ou não protegê-los durante o procedimento. O objetivo deste estudo foi avaliar o efeito do peróxido de hidrogênio a 40% no potencial de clareamento, susceptibilidade à pigmentação, e nas variações de translucidez e brancura do Lava Ultimate (LU), Vita Enamic (VE), IPS e.max CAD (IPS) e Vita Suprinity (VS). Um espectrofotômetro CM- 2600d (Konica Minolta) foi utilizado para registrar as coordenadas de cor CIE L*, a* e b*. Para o potencial de clareamento, oitenta discos de cada material foram analisados inicialmente (R0) e após a imersão em água deionizada ou café por 36,5 dias seguido ou não pelo clareamento (R1). Para a susceptibilidade à pigmentação, oitenta discos de cada material foram analisados inicialmente (R0') e após terem sido clareadas ou não e imersos em água deionizada ou café (R1'). O potencial de clareamento e a susceptibilidade à pigmentação foram calculados como a diferença de cor (ΔE00), respectivamente, entre R1-R0 e R1'-R0'. Diferenças na translucidez (ΔTP00) e no índice de brancura (ΔWID) entre R1-R0 e R1'-R0' também foram calculadas. Os dados foram analisados por ANOVA a 3 fatores e pós teste de Games-Howell (α=0,05). A significância clínica foi avaliada com base nos limiares de 50%:50% perceptibilidade e 50%:50% aceitabilidade para ΔE00, ΔTP00 e ΔWID. O café aumentou a ∆E00 no LU, VE e ... (Resumo completo, clicar acesso eletrônico abaixo)
Mestre
APA, Harvard, Vancouver, ISO, and other styles
45

Peixoto, Maur?cio Tomazoni. "Influ?ncia da espessura e grau de translucidez dos materiais nanocer?micos utilizados em CAD/CAM e do tipo de cimento na cor final de facetas." Pontif?cia Universidade Cat?lica do Rio Grande do Sul, 2016. http://tede2.pucrs.br/tede2/handle/tede/7297.

Full text
Abstract:
Submitted by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-05-23T17:30:49Z No. of bitstreams: 1 DIS_MAURICIO_TOMAZONI_PEIXOTO_COMPLETO.pdf: 977170 bytes, checksum: 550fe78287feca797929ac42cf3a7c9c (MD5)
Made available in DSpace on 2017-05-23T17:30:49Z (GMT). No. of bitstreams: 1 DIS_MAURICIO_TOMAZONI_PEIXOTO_COMPLETO.pdf: 977170 bytes, checksum: 550fe78287feca797929ac42cf3a7c9c (MD5) Previous issue date: 2016-12-13
Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq
The increasing demand for aesthetic restorations, associated with the evolution of techniques and materials, allowed the preparation of prosthetic pieces of reduced thickness. The introduction of CAD / CAM technology has made accurate and fast restorations. However, the final color of the restoration remains the direct responsibility of the dentist, where a visual assessment of color can cause errors, while an instrumental color measurement has accurate readings. The objective of the study was to investigate the factors that may influence the final color and translucency of different veneers with different thicknesses made by CAD/CAM materials and different types of resin cements on a darkened substrate. The samples were made by copy biogeneric in the CEREC SW 4.2 system, after a sample calculation of the pilot project, 60 upper central incisors of the right side of color C3 of epoxy resin were selected in 12 groups of 5 elements, divided according to type of (Lava Ultimate HT and LT), facet thickness (0.3mm / 0.6mm / 1.0mm) and cement type (Relyx Ultimate and Relyx Veneer). After cementation, the samples were taken with the spectrophotometer at a value of ?E in 6 different times with a silicone guide on the tooth, which ensures that the color is uniform. The results showed a significant difference in the values of ?E in groups 1 and 4 (HT and LT of 0.3 mm) cemented with Relyx Ultimate, in groups 7 and 9 (HT of 0.3 mm and 1.0 mm), and in groups 10 And 12 (LT of 0.3mm and 1.0mm) cemented with Relyx Veneer. However, the results were not significant for the masking of the darkened substrate over time, however, significant differences in ?E values were.
A crescente demanda por restaura??es est?ticas, associada a evolu??o das t?cnicas e materiais, possibilitaram a confec??o de pe?as prot?ticas de espessuras reduzidas. A introdu??o da tecnologia CAD/CAM possibilitou a realiza??o de restaura??es precisas e exatas rapidamente. No entanto, a cor final da restaura??o continua sendo responsabilidade direta do dentista, onde uma avalia??o visual de cor pode ocasionar erros, enquanto uma medi??o de cor instrumental possui leituras precisas. O objetivo do estudo foi realizar uma investiga??o dos fatores que podem influenciar a cor final e translucidez de facetas com diferentes espessuras confeccionadas por materiais CAD/CAM e diferentes tipos de cimentos resinosos sobre um substrato escurecido. As amostras foram confeccionadas por c?pia biogen?rica no sistema CEREC SW 4.2, ap?s c?lculo amostral do projeto piloto, foram selecionados 60 incisivos centrais superiores do lado direito de cor C3 de resina ep?xi foram divididos em 12 grupos de 5 elementos, divididos de acordo com tipo de material (Lava Ultimate HT e LT), espessura da faceta (0,3mm/ 0,6mm/ 1,0mm) e tipo de cimento (Relyx Ultimate e Relyx Veneer). Ap?s a cimenta??o, realizou-se a tomada de cor das amostras com o espectrofot?metro pelo valor de ?E em 6 tempos distintos com uma guia de silicone sobre o dente, que garante que a tomada de cor seja uniforme. Os resultados mostraram diferen?a significativa nos valores de ?E nos grupos 1 e 4 (HT e LT de 0,3mm) cimentados com Relyx Ultimate, nos grupos 7 e 9 (HT de 0,3mm e 1,0mm), e nos grupos 10 e 12 (LT de 0,3mm e 1,0mm) cimentados com Relyx Veneer. Entretanto os resultados n?o foram significativos quanto ao mascaramento do substrato escurecido ao longo do tempo, entretanto, foram observadas diferen?as significativas nos valores de ?E ao longo do tempo em uma an?lise intra-grupos.
APA, Harvard, Vancouver, ISO, and other styles
46

Cotte, Laura. "Devenir des éléments métalliques en milieu hydrothermal profond : partition dissous-particulaire effective et spéciation dans le mélange fluide hydrothermal-eau de mer précoce." Thesis, Brest, 2017. http://www.theses.fr/2017BRES0116/document.

Full text
Abstract:
Quarante ans après la découverte de la circulation hydrothermale profonde, les processus chimiques se produisant dans le mélange entre le fluide hydrothermal et l’eau de mer restent mal contraints. Ce travail de thèse, dont l’originalité repose sur l’utilisation systématique de la filtration in situ, présente le partitionnement effectif des éléments métalliques majeurs (principalement Fe, Cu, Zn, Ba et Ca) entre les phases dissoutes (< 0,45 μm) et particulaire (> 0,45 μm) dans le mélange précoce-intermédiaire de plusieurs fumeurs du champ hydrothermal Lucky Strike (37°N, MAR). Le comportement et la spéciation du Cu dans la fraction dissoute sont ensuite explorés plus en détail par le biais de compétitions de ligands et de mesures voltamétriques. Nos résultats démontrent en premier lieu l’importance de la filtration in situ pour s’affranchir des biais induits par le prolongement des réactions de précipitation ou de redissolution pouvant se produire lors de la remontée des échantillons. L’examen des fluides collectés à différentes reprises et sur une large panoplie de fumeurs (240 échantillons) démontre une variabilité spatiale des signatures chimiques le long de l'axe est-ouest du champ hydrothermal. Parmi les métaux étudiés, Fe, Ca et Ba sont principalement mesurés sous forme dissoute tandis que Cu et Zn sont majoritairement particulaires. Dans le mélange initital (50‒150°C, dMn > 50 μM), le pool de particules est dominé par de la sphalérite (ou wurtzite) et de la chalcopyrite, avec généralement moins de pyrite. Dans cette zone, les changements chimiques semblent cinétiquement limités et les fluides échantillonnés présentent une signature chimique proche de celle du fluide pur. Cependant, à mesure que le fluide hydrothermal se mélange à l'eau de mer (4‒50°C, dMn < 50 μm), le partitionnement de certains métaux alcalins et alcalinoterreux (Ca, Ba, Mg et Sr) entre les deux phases est profondément affecté par la précipitation de sulfates. Contrairement aux prédictions thermodynamiques, la précipitation d’anhydrite, de barite et potentiellement de caminite est observée dans la partie relativement froide du mélange (4-50°C). L’augmentation importante du pH dans cette zone conduit également à l’initiation de la précipitation d’oxydes de Fe. Enfin, dans la phase dissoute, les ligands du Cu semblent être principalement des sulfures inorganiques issus du fluide hydrothermal
Forty years after the discovery of deep hydrothermal circulation, chemical processes occurring in the early mixing between hydrothermal vent fluids and deep seawater are still not fully constrained. This thesis, whose the originality lies on the systematic use of in situ filtration, report on the partitioning of major metals (mainly Fe, Cu, Zn, Ba and Ca) between the dissolved (< 0.45 μm) and particulate (> 0.45 μm) phases in the early mixing of several black and clear smokers from the Lucky Strike vent field (37°N, MAR). The behavior and the speciation of Cu in the dissolved fraction are then deeper explored by performing ligands competition and voltammetric measurements. Our results first demonstrate the importance of the in situ filtration to restrict the bias induced by precipitation reactions or particles redissolution potentially occurring postsampling.The examination of the fluids collected at several occasions and on a wide range of smokers (240 samples) shows a spatial variability of chemical signatures along the east-west axis of the hydrothermal field. Among metals studied, most of Fe, Ca and Ba are measured as dissolved species whereas Cu and Zn are mainly found as particles. In the initial part of the mixing (50-150°C, dMn > 50 μM), the particulate pool is dominated by sphalerite (or wurtzite) and chalcopyrite, with generally lower amount of pyrite. In this zone, chemical changes seem kinetically limited and fluids collected display a chemical signature close to that of the end-members. However, as the hydrothermal fluid progressively mixes with seawater (4-50°C, dMn < 50 μm), the partitioning of some alkali and alkaline earth metals (Ca, Ba, Mg and Sr) between the two phases is deeply affected by precipitation of sulfates. Unlike thermodynamic predictions, precipitation of anhydrite, barite and potentially caminite is observed in the colder part of the mixing (4-50°C). The large increase of pH in this area also drives the beginning of Fe oxides precipitation. Finally, the dissolved Cu-ligands detected seem to be mainly inorganic sulfides originating from the hydrothermal fluid
APA, Harvard, Vancouver, ISO, and other styles
47

Gevaux, Lou. "3D-hyperspectral imaging and optical analysis of skin for the human face." Thesis, Lyon, 2019. http://www.theses.fr/2019LYSES035.

Full text
Abstract:
L’imagerie hyperspectrale (HSI), une méthode non invasive permettant de mesurer in vivo la réflectance spectrale, a démontré son fort potentiel pour l’analyse des propriétés optiques de la peau pour des zones planes et de petite taille : l’association d’un modèle optique de peau, d’une modélisation de ses interactions avec la lumière et d’une méthode d’optimisation permet d’analyser l’image hyperspectrale en chaque pixel et d’estimer des cartographies de concentrations en chromophores, comme la mélanine et le sang. Le but de ce travail est l’extension de la méthode pour la mesure et l’analyse de surfaces larges et non planes, et en particulier du visage humain. Les mesures d’objets complexes comme le visage sont affectées par des variations spatiales d’éclairement, que l’on appelle dérives d’éclairement. A moins d’être prises en compte dans le modèle, celles-ci créent des erreurs dans l’analyse des images.Nous proposons en 1ère partie de ce travail une caméra HSI grand-champ (acquisition de bandes spectrales de 10 nm de largeur entre 400 et 700 nm), combinée avec un système d’acquisition de la géométrie 3D par projection de franges. Une acquisition courte étant cruciale in vivo, un compromis entre résolution et vitesse d’acquisition permet un temps d’acquisition inférieur à 5 secondes.La caméra HSI a été associée avec un scanner 3D afin de corriger les dérives d’éclairement en utilisant la géométrie 3D et des principes de radiométrie. L’éclairement reçu par le visage est calculé en chaque pixel puis utilisé pour supprimer les dérives d’éclairement dans l’image hyperspectrale, un prétraitement à appliquer avant l’analyse. Cependant, cette méthode n’est pas satisfaisante sur les zones du visage pratiquement perpendiculaires à l’axe optique de la caméra, comme les côtés du nez, et a été rejetée en faveur d’un algorithme d’optimisation robuste aux dérives d’éclairement dans la méthode d’analyse.L’analyse de la peau à partir des images hyperspectrales est basée sur l’utilisation de modèles optiques. La peau est modélisée par un matériau translucide à deux couches dont les propriétés d’absorption dépendent de sa composition en chromophores. Les interactions lumière-peau sont modélisées à l’aide d’une approche à deux flux. La résolution d’un problème inverse par optimisation permet d’estimer la composition en chromophores à partir de la réflectance spectrale mesurée. Les modèles optiques choisis sont un bon compromis entre une description fidèle de la peau et un temps de calcul acceptable, qui augmente de manière exponentielle avec le nombre de paramètres du modèle. Les cartes de chromophores estimées peuvent être affichées sous forme 3D grâce à l’information mesurée par la caméra HSI-3D.Un point faible de la méthode est le manque d’information sur les propriétés de diffusion de la peau, considérées identiques d’une personne à l’autre et d’une partie du corps à l’autre. Dans la 2nd partie de ce travail, nous utilisons le projecteur de franges initialement dédié à l’acquisition 3D, pour mesurer la fonction de transfert de modulation (FTM) de la peau, qui fournit de l’information sur l’absorption et la diffusion. La FTM est mesurée par imagerie dans le domaine fréquentiel spatial (SFDI) et analysée avec l’équation de la diffusion pour estimer le coefficient de diffusion de la peau. Sur des objets non-plats, l’extraction d’information indépendamment des dérives d’éclairement est un défi important. L’originalité de la méthode proposée repose sur l’association de la HSI et SFDI dans le but d’estimer des cartes de coefficient de diffusion sur le visage indépendamment de sa forme.Nous insistons sur l’importance d’une acquisition courte pour des mesures in vivo, cependant, l’analyse par optimisation demande plusieurs heures de calcul. L’utilisation des réseaux de neurones comme alternative à l’optimisation nous semble prometteur, des premiers résultats ayant montré une forte réduction du temps de calcul, d’environ 1 heure à 1 seconde
Hyperspectral imaging (HSI), a non-invasive, in vivo imaging method that can be applied to measure skin spectral reflectance, has shown great potential for the analysis of skin optical properties on small, flat areas: by combining a skin model, a model of light-skin interaction and an optimization algorithm, an estimation of skin chromophore concentration in each pixel of the image can be obtained, corresponding to quantities such as melanin and blood. The purpose of this work is to extend this method to large, non-flat areas, in particular the human face. The accurate measurement of complex objects such as the face must account for variances of illumination that result from the 3D geometry of an object, which we call irradiance drifts. Unless they are accounted for, irradiance drifts will lead to errors in the hyperspectral image analysis.In the first part of the work, we propose a measurement setup comprising a wide field HSI camera (with an acquisition range of 400 - 700 nm, in 10 nm width wavebands) and a 3D measurement system using fringe projection. As short acquisition time is crucial for in vivo measurement, a trade-off between resolution and speed has been made so that the acquisition time remains under 5 seconds.To account for irradiance drifts, a correction method using the surface 3D geometry and radiometry principles is proposed. The irradiance received on the face is computed for each pixel of the image, and the resulting data used to suppress the irradiance drifts in the measured hyperspectral image. This acts as a pre-processing step to be applied before image analysis. This method, however, failed to yield satisfactory results on those parts of the face almost perpendicular to the optical axis of the camera, such as the sides of the nose, and was therefore discarded in favor of using an optimization algorithm robust to irradiance drifts in the analysis method.Skin analysis from the measured hyperspectral image is performed using optical models and an optimization method. Skin is modeled as a two-layer translucent material whose absorption and scattering properties are determined by its composition in chromophores. Light-skin interactions are modeled using a two-flux method. An inverse problem is solved by optimization to retrieve information about skin composition from the measured reflectance. The chosen optical models represent a trade-off between accuracy and acceptable computation time, which increases exponentially with the number of parameters in the model. The resulting chromophore maps can be added to the 3D mesh measured using the 3D-HSI camera for display purposes.In the spectral reflectance analysis method, skin scattering properties are assumed to be the same for everyone and on every part of the body, which represents a shortcoming. In the second part of this work, the fringe projector originally intended for measuring 3D geometry is used to acquire skin modulation transfer function (MTF), a quantity that yields information about both skin absorption and scattering coefficients. The MTF is measured using spatial frequency domain imaging (SFDI) and analyzed by an optical model relying on the diffusion equation to estimate skin scattering coefficients. On non-flat objects, retrieving such information independently from irradiance drifts is a significant challenge. The novelty of the proposed method is that it combines HSI and SFDI to obtain skin scattering coefficient maps of the face independently from its shape.We emphasize throughout this dissertation the importance of short acquisition time for in vivo measurement. The HSI analysis method, however, is extremely time-consuming, preventing real time image analysis. A preliminary attempt to address this shortcoming is presented, using neural networks to replace optimization-based analysis. Initial results of the method have been promising, and could drastically reduce calculation time from around an hour to a second
APA, Harvard, Vancouver, ISO, and other styles
48

Capllonch, Begoña. "De la plausibilitat referencial del llenguatge poètic: Francis Ponge, o el cas d'una poètica referencialista." Doctoral thesis, Universitat Pompeu Fabra, 2010. http://hdl.handle.net/10803/7449.

Full text
Abstract:
L'objecte d'aquesta tesi ha estat el de defensar, a partir de l'exemple de l'obra de Francis Ponge, la plausibilitat referencial del llenguatge poètic, supòsit tot sovint rebatut a causa d'una radicalització del tòpic de l'autoreferencialitat poètica i per un planteig en suma restringit del concepte de la referencialitat. Però que un poema es constitueixi en tant que específica configuració significant no hauria d'implicar un menyscabament de la seva capacitat de representació, perquè si la poesia és creació mitjançant el llenguatge, tot allò que jutgem poètic no dimanaria sinó de la mateixa idiosincràsia de l'expressió verbal. Així doncs, hem argumentat, en primer lloc, l'efectivitat referencial del llenguatge ordinari per tal d'il·lustrar tot seguit la del poètic i, en particular, la que explicitaria el verb de Francis Ponge, atès que la poètica d'aquest autor es caracteritza, precisament, pel fet d'obstinar-se en una convençuda referencialitat: la que l'impel·lí a dirigir-se envers les coses; la que el dugué a submergir-se en les paraules.
El objeto de esta tesis ha sido el de defender, a partir del ejemplo de la obra de Francis Ponge, la plausibilidad referencial del lenguaje poético, supuesto a menudo rebatido a causa de una radicalización del tópico de la autorreferencialidad poética y por un planteamiento en suma restringido del concepto de la referencialidad. Pero que un poema se constituya en tanto que particular configuración significante en modo alguno implicaría un menoscabo de su capacidad de representación, porque si la poesía es creación mediante el lenguaje, todo lo que juzgamos poético no dimanaría sino de la propia idiosincrasia de la expresión verbal. Así pues, hemos argumentado, en primer lugar, la efectividad referencial del lenguaje ordinario para ilustrar a continuación la del poético y, en particular, la que explicitaría el verbo de Francis Ponge, pues la poética de este autor se caracteriza, precisamente, por obstinarse en una convencida referencialidad: la que lo impulsó a dirigirse hacia las cosas; la que lo condujo a sumergirse en las palabras.
Starting from Francis Ponge's work, this PhD thesis argues for the referential plausibility of the poetic language. This assumption has often been contested partly because of the cliché of poetic self-referentiality and partly because the concept of referentiality has had an extremely restricted approach. This thesis suggests that, on the contrary, a poem's capability of becoming a particular and significant configuration does by no means imply a lessening of its representative force. Indeed: if poetry is creation by means of language, everything we judge as poetic stems solely from the idiosyncrasy of verbal expression. Thus, the thesis argues for the referential efficiency of ordinary language to then illustrate the referential efficiency of the poetic. It focuses in particular on the verbum as put forth by Francis Ponge. This author's poetics is best characterized by its persistence in a convinced referentiality, which leads Ponge to address things, and which takes him to sound the depths of words.
APA, Harvard, Vancouver, ISO, and other styles
49

Ditu, Gabriel Cristian Computer Science &amp Engineering Faculty of Engineering UNSW. "The programming language TransLucid." 2007. http://handle.unsw.edu.au/1959.4/40701.

Full text
Abstract:
This thesis presents TransLucid, a low-level, purely declarative, intensional programming language. Built on a simple algebra and with just a small number of primitives, TransLucid programs define arbitrary dimensional infinite data structures, which are then queried to produce results. The formal foundations of TransLucid come from the work in intensional logic by Montague and Scott. The background chapters give a history of intensional logic and its predecessors in the Western world, as well as a history of intensional programming and Lucid, the first intensional programming language. The semantics of TransLucid are fully specified in the form of operational semantics. Three levels of semantics are given, in increasing order of efficiency, with the sequential warehouse semantics, the most efficient, being presented together with a proof that any expression will be evaluated by only examining relevant dimensions in the current context. The language is then extended in three important ways, by adding versioned identifiers, (declarative) side-effects and timestamped equations and demands. Adding versioned identifiers to TransLucid enriches the expressiveness of the language and allows the encoding of a variety of programming paradigms, ranging from manipulating large data-cubes to pattern-matching. Adding side-effects supports one of the main reasons for TransLucid: namely, to provide a target language, together with a methodology, for translating the main programming paradigms, thus creating a uniform end platform that can be the focus for optimisation and program verification. A translation of imperative programs into TransLucid is given. Timestamped equations and demands enable TransLucid to become a language for synchronous programming in real-time systems, as well as allowing runtime updates to a program's equations. The language TransLucid represents a decisive advance in declarative programming. It has applications in many fields of computer science and opens up exciting new avenues of research.
APA, Harvard, Vancouver, ISO, and other styles
50

Pereira, Ana Filipa da Cruz. "Translucidez de diferentes zircónias." Master's thesis, 2018. http://hdl.handle.net/10400.26/23521.

Full text
Abstract:
Dissertação para obtenção do grau de Mestre no Instituto Universitário Egas Moniz
Objetivo: O objetivo deste estudo foi comparar a translucidez de diferentes tipos e espessuras de zircónia. Materiais e métodos: Foram fresados 20 espécimes de zircónia monolítica UT (Bloomden W00098014UT) e 20 espécimes de zircónia multilayer ST (Bloomden W00098016ST- ML-A2), pré-sinterizados, através do sistema CAD/CAM. Definiram-se 4 grupos segundo a espessura (0.5, 1.0, 1.5, 2.0 mm) tanto no grupo da zircónia monolítica como no grupo da zircónia multilayer, n=5. Os espécimes de zircónia monolítica foram submersos no corante (BloomZir® UT Coping Crown A2) durante 2 minutos, segundo as indicações do fabricante. Posteriormente, todos os espécimes foram sinterizados no forno (IMES-Wieland Zeno® Fire). Por fim, todos os espécimes foram submetidos a um banho de ultrassons. Os valores de L*, a* e b* foram medidos através do espectrofotómetro SpectroShade Micro em 6 localizações diferentes. A translucidez dos espécimes foi calculada através de duas fórmulas distintas: a relação de contraste (CR =𝐿𝑏𝐿𝑤) e o parâmetro de translucidez (TP=[(𝐿𝑏−𝐿𝑤)2+(𝑎𝑏−𝑎𝑤)2+(𝑏𝑏−𝑏𝑤)2]12⁄). Todos os dados foram analisados estatisticamente. Resultados: Os valores de TP variaram entre 14,092 a 26,666 na zircónia UT monolítica e 9,997 a 18,624 na zircónia ST multilayer. Com o aumento da espessura verificou-se um decréscimo no TP em ambos os materiais. Os valores de CR variaram entre 0,718 a 0,862 na zircónia UT monolítica e 0,804 a 0,905 na zircónia ST multilayer. Com o aumento da espessura verificou-se um aumento no CR em ambos os materiais. Verificaram-se diferenças estatisticamente significativas na translucidez entre os materiais (p<0.001), entre as diferentes espessuras (p<0.001) e entre a interação da espessura com o material (p<0.001). Conclusões: A zircónia UT monolítica demonstrou-se mais translúcida do que a zircónia ST multilayer. A translucidez foi afetada tanto pelo tipo de material como pela espessura. Quanto maior a espessura do material menor a translucidez.
Objective: The aim of this study was to compare the translucency of different types and thicknesses of zirconia. Materials and methods: 20 specimens of pre-sintered UT monolithic zirconia (Bloomden W00098014UT) and 20 specimens of pre-sintered ST multilayer zirconia (Bloomden W00098016ST- ML-A2) were cut through the CAD/CAM system. Four groups were defined according to thickness (0.5, 1.0, 1.5, 2.0 mm) in both monolithic and multilayer zirconia (n=5). The monolithic zirconia specimens were colored with coloring liquid (BloomZir® UT Coping Crown A2) for 2 minutes, according to the manufacturer’s instructions. Subsequently, all zirconia specimens were sintered in the furnace (IMES-Wieland Zeno® Fire). Finally, all specimens were cleaned in an ultrasonic bath. The values of L*, a* and b* were measured using the spectrophotometer SpectroShade Micro at 6 different locations. The translucency of the specimens was calculated using two different formulas: the contrast ratio (CR =𝐿𝑏𝐿𝑤) and the translucency parameter (TP=[(𝐿𝑏−𝐿𝑤)2+(𝑎𝑏−𝑎𝑤)2+(𝑏𝑏−𝑏𝑤)2]12⁄). All data was analyzed statistically. Results: TP values ranged from 14.092 to 26.666 in UT monolithic zirconia and 9.997 to 18.624 in ST multilayer zirconia. With the increase of thickness there was a decrease in TP in both materials. CR values ranged from 0.718 to 0.862 in UT monolithic zirconia and 0.804 to 0.905 in the ST multilayer zirconia. The increase in thickness showed an increase in CR in both materials. There were statistically significant differences in the translucency between the material (p<0.001), the different thicknesses (p<0.001) and between the interaction of thickness and material (p<0.001). Conclusions: UT monolithic zirconia was more translucent than the ST multilayer zirconia. The translucency was affected by both the type of material and thickness. The greater the thickness of the material the lower the translucency.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography