Dissertations / Theses on the topic 'Termoluminescenza'

To see the other types of publications on this topic, follow the link: Termoluminescenza.

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Termoluminescenza.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

MONTI, ANDREA MAURIZIO. "Point defects in quartz: Role in trapping and luminescence." Doctoral thesis, Università degli Studi di Milano-Bicocca, 2021. http://hdl.handle.net/10281/311082.

Full text
Abstract:
In questo lavoro di tesi sono state studiate le proprietà di intrappolamento e luminescenza dei difetti di punto nel quarzo. Tali proprietà sono usate in dosimetria retrospettiva al fine di valutare età archeologiche di reperti ceramici, età geologiche di sedimenti e radiazioni assorbite in casi di incidenti nucleari. Lo studio vuole fare chiarezza sui meccanismi specifici che governano tali proprietà nel quarzo. Nonostante il materiale sia arcinoto e già esistano applicazioni di questo materiale nei campi citati, queste ultime si basano su metodi empirici ed una teoria che possa spiegare e prevedere nel dettaglio le emissioni del quarzo è ancora incompleta. Per fare ciò, sono state sfruttate sia tecniche di luminescenza indotte, direttamente o indirettamente, da radiazioni ionizzanti quali termoluminescenza (TL) e radioluminescenza (RL), sia una tecnica che studia i difetti paramagnetici, o in generale elettroni non accoppiati, ovvero la risonanza paramagnetica elettronica (EPR). TL e RL infatti non sono in grado da sole di poter identificare quali difetti siano responsabili delle emissioni del quarzo, ma è possibile cercare correlazioni usando tecniche che invece possono osservare direttamente tali difetti, come appunto la tecnica EPR. Correlando dati di TL ed EPR è stato possibile identificare impurezze di germanio con elettroni intrappolati, in particolare le trappole per elettroni [GeO4]- e [GeO4/Li+]0, come responsabili di emissioni di TL, i cosiddetti picchi a 110 °C e 375 °C. Nel corso dello studio è stato inoltre possibile individuare un'anomalia nella stabilità termica di uno di questi centri germanio, responsabile per il picco a 110 °C, confermando comunque la correlazione tra i due segnali ma sollevando nuove possibili criticità nelle applicazioni a fini di datazione e dosimetria. Tramite gli studi EPR è stato inoltre possibile individuare nuovi centri paramagnetici mai riportati in letteratura e ne è stata caratterizzata la stabilità termica. Uno di essi è stato assegnato a un centro compensato con idrogeno interstiziale, mentre gli altri ancora necessitano una precisa assegnazione. È stata inoltre studiata la stabilità termica di centri legati a impurezze di titanio e alluminio al fine di cercare possibili correlazioni con proprietà di luminescenza. Delle possibilità sono state proposte, ma sono necessari ulteriori studi riguardo questo specifico punto. Tramite RL e TL è stato mostrato inoltre come le lunghezze d'onda di emissione del quarzo siano molto dipendenti dal tipo di campione studiato e dalla sua storia termica. In particolare, tramite TL risolta in lunghezza d'onda è stato possibile mostrare come le proprietà dei campioni studiati non siano in accordo con alcuni modelli teorici pubblicati in letteratura. Lo studio ha consentito di proporre un'alternativa, seppur finora come modello qualitativo. Tale proposta sostiene che possano esistere correlazioni spaziali tra diversi difetti di punto nel quarzo, consentendo ricombinazioni specifiche senza l'ausilio delle bande di conduzione e valenza del materiale. Benché lo studio sia ben lontano dall'aver trovato una descrizione completa nei comportamenti del quarzo, nuovi importanti tasselli sono stati aggiunti ai decenni di studi pubblicati, avvicinando la comunità scientifica al traguardo finale della comprensione dei processi di luminescenza di questo materiale.
In this thesis work, the trapping and luminescence properties of point defects in quartz have been studied. Such properties are used in retrospective dosimetry in order to evaluate the age of archaeological artefacts, the age of geological sediments and the absorbed radiation in the event of nuclear accidents. The study aims at clarifying the specific mechanisms that rule such properties in quartz. Despite being quartz a well-known material and many applications in the aforementioned fields already existing, these are based on empirical methods and a theory that can explain and predict the emissions in quartz in a detailed way is still incomplete. To do so, two luminescence techniques are used, both induced, directly or indirectly, by ionizing radiation such as thermoluminescence (TL) and radioluminescence (RL), and a technique to study paramagnetic defects, or in general unpaired electrons, that is electron paramagnetic resonance (EPR). In fact, TL and RL alone are not enough to directly identify the defects that are responsible for such emissions, but it is possible to try to correlate their data with other techniques that can directly observe such defects, such as EPR. By correlating TL and EPR data, germanium related centres with trapped electrons, specifically [GeO4]- and [GeO4/Li+]0, have been identified as responsible for the TL emissions known as the peaks at 110 °C and 375 °C. At the same time, it was also possible to identify an anomaly in the thermal stability of one of these germanium centres, responsible for the 110 °C peak, confirming the correlation of the two signals, TL and EPR, but also raising new potential critical issues in the applications for dating and dosimetry. Through EPR studies, new unreported paramagnetic centres have been identified and their thermal stability has been characterized. One of them has been assigned to a centre compensated by interstitial hydrogen, while the others are still lacking a precise labelling. The thermal stability of titanium and aluminium related centres has also been studied, in search of possible correlations with luminescence properties. Some proposals have been advanced, but further studies are needed for this last specific point. Through RL and TL, it has been shown how the emission wavelengths in quartz are very sample dependent and how they are influenced by the thermal history of the studied sample. Specifically, through wavelength resolved TL it was possible to show how the properties of the studied samples do not agree with some published theoretical models. The study was able to propose an alternative, although so far just at a qualitative level. Such proposal claims that there may be spatial correlations between point defects in quartz, allowing specific direct recombination with no passage in the conduction and valence bands of the material. Despite this study is far from having found a complete description of quartz behaviour, new important steps have been added to the huge specific literature, contributing to a deeper comprehension of the luminescence properties of this material.
APA, Harvard, Vancouver, ISO, and other styles
2

SANTOS, Robson Alves dos. "Caracterização da emissão termoluminescente da fluorita natural." Universidade Federal de Pernambuco, 2016. https://repositorio.ufpe.br/handle/123456789/24569.

Full text
Abstract:
Submitted by Alice Araujo (alice.caraujo@ufpe.br) on 2018-05-07T18:09:17Z No. of bitstreams: 1 DISSERTAÇÃO Robson Alves dos Santos.pdf: 7541270 bytes, checksum: 50bbbfbfd96d388f75b6542eb954e13b (MD5)
Made available in DSpace on 2018-05-07T18:09:17Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO Robson Alves dos Santos.pdf: 7541270 bytes, checksum: 50bbbfbfd96d388f75b6542eb954e13b (MD5) Previous issue date: 2016-08-31
CAPES
O fluoreto de cálcio, também conhecido como fluorita é um mineral presente em vários continentes e se apresenta com diferentes colorações. As suas propriedades luminescentes tem sido estudadas visando a aplicação em dosimetria das radiações ionizantes. Contudo, há poucos estudos a respeito do espectro de emissão termoluminescente (TL) da fluorita e a sua correlação com a coloração do mineral. Neste trabalho, se propõe avaliar a emissão termoluminescente de 77 cristais de fluorita de diferentes colorações, dentre elas amarelo, azul, incolor, marrom, preto, roxo e verde, procedentes das Américas do Norte e do Sul, África, Ásia e Europa, com o objetivo de se obter dados que sirvam de referência para o estudo TL e do espectro de emissão e que contribuam para um maior conhecimento das características deste mineral. Para tanto, foi produzido CaF2 sintético dopado com diferentes impurezas para comparação com o espectro de emissão da fluorita natural. Fragmentos de cristais de fluorita foram manualmente pulverizados e pastilhas de uma mistura homogênea de fluorita particulada e politetrafluoretileno floculado em temperatura ambiente foram produzidas. Em seguida, as pastilhas foram irradiadas com uma fonte de 137Cs emissora de radiação gama com doses entre 0,1 a 10 mGy, para avaliar a curvas de intensidade TL. A análise mostrou não haver relação entre a coloração e as impurezas presentes nos cristais de fluorita. Apesar disso, amostras de todas as colorações apresentaram disprósio. O espectro de emissão TL mostrou que os cristais da América do Sul, África e Ásia, em geral possuem as impurezas cério (Ce), disprósio (Dy) e érbio (Er), enquanto as procedentes da Europa apresentam Dy. Alguns exemplares da África e Ásia apresentaram as impurezas térbio (Tb) e manganês (Mn). As curvas de intensidade TL apresentaram picos similares e sobrepostos nas mesmas temperaturas. Para o Brasil, a fluorita verde de Santa Catarina e roxa da Paraíba, foram as mais sensíveis para emissão TL. Contudo a fluorita roxa, procedente da China, apresentou a maior sensibilidade TL entre as amostras estudadas. As amostras com Ce mostraram maior sensibilidade para as analises TL. A resposta TL em função da dose de radiação se mostrou linear. Tais resultados indicam a possibilidade de se utilizar o material para dosimetria.
Calcium fluoride, also known as fluorite, is a mineral found in several continents and can be presented in different colorations. Their luminescent properties have been studied with a view to application in dosimetry of ionizing radiation. However, there are few studies about the thermoluminescence emission spectrum (TL) of fluorite and its correlation with the color of the mineral. In this work, we propose to evaluate the luminescence response of 77 fluorite crystals of different colors, among them yellow, blue, colorless, brown, black, purple and green, coming from North and South America, Africa, Asia and Europe, in order to obtain data that serve as a reference for the study of TL and emission spectrum of this material, contributing to a better understanding of its characteristics. Thus, synthetic CaF2 doped with different impurities was produced for comparison with the emission spectrum of natural fluorite. Fluorite crystal fragments were manually pulverized and then pallets were produced by a homogeneous mixture of particulate fluorspar and flocculated polytetrafluoroethylene at room temperature. Then, the pellets were irradiated with a 137Cs source emitting gamma radiation with doses ranging from 0.1 to 10 mGy to evaluate the intensity of TL curves. The analysis showed no relationship between color and impurities present in fluorite crystals. Nevertheless, all the samples contained dysprosium. The TL emission spectrum showed that the crystals of South America, Africa and Asia generally contain the impurities cerium (Ce), dysprosium (Dy) and erbium (Er), while those from Europe present Dy. Some samples from Africa and Asia presented the impurities terbium (Tb) and manganese (Mn). The TL intensity curves showed similar and overlapping peaks at the same temperatures. For Brazil, the green fluorite from Santa Catarina and the purple from Paraíba, were the most sensitive to TL emission, respectively. However, purple fluorite, coming from China, had the highest TL sensitivity among the studied samples. Samples with impurity cerium showed greater sensitivity to the TL analysis. The TL response as a function of radiation dose was linear. These results indicate the possibility of using the material for dosimetry.
APA, Harvard, Vancouver, ISO, and other styles
3

Morlotti, Marcelo Scolaro. "Verificação de tratamentos radioterápicos diversos com dosimetria termoluminescente." Universidade de São Paulo, 2007. http://www.teses.usp.br/teses/disponiveis/43/43134/tde-09052007-195209/.

Full text
Abstract:
As técnicas radioterápicas evoluíram muito nas últimas décadas, destacando-se a utilização de feixes segmentados por colimadores de multifolhas, os quais permitem entregar maior quantidade de dose com maior precisão espacial. Os sistemas de planejamento em radioterapia (TPS), entretanto, são em grande parte fechados, com acesso restrito aos parâmetros de cálculo de dose. Desta forma, o presente trabalho teve como principal objetivo comparar valores de dose envolvidas em tratamentos radioterápicos, medidos com a técnica de dosimetria termoluminescente (TL), usando um objeto simulador antropomórfico (Alderson Rando Phantom - ARP) como paciente, com valores de referência extraídos dos TPS em simulações realistas de tratamento. O objeto simulador continha dosímetros TL de LiF (TLD100) posicionados na pelve, no tórax, na cabeça e no pescoço, a fim de que fossem monitoradas regiões com dose homogênea (como no volume alvo planejado - PTV), regiões com gradiente de dose e regiões afastadas do PTV. As irradiações foram feitas usando técnicas de radioterapia conformacional 3D e radioterapia por modulação da intensidade do feixe (IMRT). Quatro TPS foram utilizados: CadPlan, ECLIPSE, Helax-TMS e KonRad. Em algumas situações utilizaram-se algoritmos de cálculo implementados pelos fabricantes nos TPS; dois deles baseados em correção de heterogeneidades (Batho e pencil beam) e um deles baseado em convolução e superposição de feixes simulados (collapsed cone). Nos casos de irradiações com IMRT os algoritmos foram sempre usados. Paralelamente ao uso do ARP, utilizou-se um objeto simulador com água com objetivo de verificar o comportamento dos dosímetros TL expostos a feixes de fótons de alta energia, em comparação com câmaras de ionização cilíndricas do tipo Farmer (volume interno de 0,6 cm3). Além disso, esse objeto simulador possibilitou garantir a qualidade de suportes desenvolvidos para a câmara e para os dosímetros, nos casos de medidas em água. A irradiação da pelve do objeto simulador ARP, região com poucas heterogeneidades, revelou que o comportamento do material que o constitui é equivalente ao da água e, por isso, pode ser usado na simulação de tecido humano em feixes de radioterapia. Simulações de tratamentos revelaram compatibilidade entre valores medidos e planejados no interior do PTV, com discrepâncias menores que 2%; valores que estão dentro dos limites estabelecidos pelo ICRU62 (+7%/-5%, 2?). Nas regiões afastadas do PTV, todos os códigos de planejamento apresentaram discrepâncias relativamente grandes, evidenciando limitações no cálculo de componentes secondárias. Apesar dos algoritmos de cálculo aumentarem a concordância entre doses medidas e planejadas, não foi possível identificar diferenças entre os algoritmos pencil beam e collapsed cone. Em regiões onde havia alto gradiente de dose, as discrepâncias se tornam maiores devido à dificuldade em posicionar os dosímetros no mesmo ponto em que o cálculo é feito. Sistematicamente, observou-se que a técnica para radioterapia 3D apresenta valores de dose dentro dos limites preestabelecidos, enquanto IMRT mostra valores com maior exatidão.
The last decades noticed a massive improvement in radiotherapy techniques and the use of segmented beams produced by multileaf collimators. However, the dose radiation therapy planning systems (TPS) in use are characterized by the restriction of access to the calculation algorithms. The aim of this work was to compare dose values measured in an anthropomorphic phantom (Alderson Rando Phantom - ARP) to the reference dose values obtained from the TPS in real case simulations of radiotherapy treatments. Thermoluminescent dosimetry (TLD) technique was used to evaluate the doses. LiF dosimeters (TLD100) were positioned on the phantom pelvis, thorax, head and neck at homogeneous dose regions, as the Planned Target Volume (PTV), gradient dose regions, and areas far from PTV. The doses were delivered using two techniques, 3D conformal radiotherapy and Intensity Modulated Radiation Therapy (IMRT). Four TPS were used: CadPlan, ECLIPSE, Helax-TMS and KonRad. In several situations, calculation algorithms implemented in these planning systems were employed to take heterogeneities into account: two of them were correction-based algorithms (Batho and Pencil Beam) and one of them based in beam convolution-superposition (Collapsed Cone). Furthermore, a liquid water phantom was used to compare the TLD behavior to the Farmer thimble chamber (0,6 cc internal volume) results when exposed to high-energy photon beams. It was also possible to verify the quality of the PMMA supports that wer used in the calibration of the dosimeters on clinical beam, obtaining reliable results. Both the ARP pelvis and a water phantom showed similar behavior under irradiation, indicating that, in highly homogenous regions, the ARP material can be used to simulate human soft tissues under radiotherapy treatment. Inside the PTV, the dosimetry performed in the ARP, showed compatibility between measured and planned dose values, with discrepancies smaller than 2%, which are within the ICRU62 fixed limits (+7%/-5%, 2?). When the algorithms were used, a better agreement between the experimental and planned doses was achieved, but it was not possible to discriminate the Pencil Beam and Collapsed Cone algorithms. In regions with large dose gradients, the discrepancies between experimental and planned dose values are higher as the difficulties the position of the dosimeters are more critical. The measured doses, when the 3D radiotherapy technique was used, were within the ICRU62 pre-established limits whereas the IMRT technique provider more accurate values.
APA, Harvard, Vancouver, ISO, and other styles
4

Saito, Monteiro de Barros Vinícius. "Síntese e caracterização da alumina para dosimetria termoluminescente." Universidade Federal de Pernambuco, 2008. https://repositorio.ufpe.br/handle/123456789/9346.

Full text
Abstract:
Made available in DSpace on 2014-06-12T23:14:14Z (GMT). No. of bitstreams: 2 arquivo8631_1.pdf: 6827931 bytes, checksum: fffed04f6b834961607b7e4354baeb5f (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
óxido de alumínio dopado com carbono (J-Al2O3:C) é um importante material para dosimetria das radiações ionizantes por leitura termoluminescente (TL). Esse material apresenta sensibilidade à radiação que é cerca de 50 vezes mais sensível que o LiF:Mg,Ti. No entanto, a sua fabricação normalmente requer técnicas de crescimento de cristais que utilizam infra-estrutura de laboratórios com fornos de altas temperaturas e sob condições atmosféricas redutoras. Tendo isto em vista, o objetivo deste trabalho é o estudo e a caracterização de duas rotas alternativas para a síntese do J-Al2O3:C: os métodos Eletroquímico e da Combustão. No método Eletroquímico, as amostras foram produzidas pela oxidação de uma placa de alumínio (99,99%), em ácido oxálico, sob uma diferença de potencial constante. Já no método da Combustão, as amostras são fabricadas misturando-se quantidades adequadas de nitrato de alumínio, uréia e um material dopante (Mg, Si, Eu, Eu-Mg, Eu-Si, Tb, Tb-Mg). Os reagentes foram aquecidos até 500 °C até obter a combustão e, em seguida as amostras foram tratadas termicamente a temperaturas entre 600 e 1500 °C. Para o método Eletroquímico, os resultados mostraram uma relação linear entre a intensidade TL linear e a dose absorvida no ar, para feixes de radiação gama do Co-60, no intervalo entre 0,5 a 4,5 Gy. Os parâmetros que resultaram na maior resposta TL foram: concentração de ácido oxálico igual a 0,10 M e tensão e tempo de anodização iguais 130 V e 300 min, respectivamente. As imagens produzidas por Microscopia Eletrônica de Varredura (MEV) mostraram que as pastilhas produzidas nessas condições apresentam poros com diâmetros que variam entre 40 e 80 nm e que a área correspondente aos poros representa cerca de 10 % da área superficial da amostra. Para o método da Combustão, as amostras apresentaram resposta TL linear com a dose absorvida no ar de radiação gama do Co-60, entre 0,05 e 5 Gy. As maiores sensibilidades à radiação foram obtidas para as amostras dopadas com Tb e Tb-Mg, tratadas a 1500 °C por 4 h. Essas amostras apresentaram curva característica de emissão TL com dois picos em cerca de 190 e 350 °C. Pode-se concluir pelos resultados que a rota de síntese por Combustão produz amostras mais sensíveis à radiação que a síntese por anodização. Os materiais obtidos abrem novas perspectivas no campo de desenvolvimento de dosímetros para aplicações em dosimetria termoluminescente
APA, Harvard, Vancouver, ISO, and other styles
5

Nunes, Maíra Goes. "Avaliação do desempenho dos detectores termoluminescentes de CaSO4:Dy e LiF:Mg, Ti na dosimetria de feixes clínicos de elétrons." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-08092009-165036/.

Full text
Abstract:
A avaliação do desempenho dos detectores termoluminescentes de CaSO4:Dy, produzidos pelo IPEN, tem como objetivo apresentar uma alternativa aos dosímetros de LiF:Mg,Ti comerciais (TLD-100), amplamente empregados em radioterapia, na dosimetria de feixes clínicos de elétrons. Os dois tipos de detectores termoluminescentes foram caracterizados, com a utilização de objetos simuladores de PMMA, água sólida do tipo RMI-457 e água, em campos de radiação de elétrons de 4, 6, 9, 12 e 16 MeV de energias nominais, nos quais as curvas de dose-resposta foram obtidas e as doses superficial e profunda foram determinadas. A dependência da resposta termoluminescente com a energia nominal dos elétrons e com o objeto simulador empregado foram estudadas. O CaSO4:Dy apresentou o mesmo comportamento do LiF:Mg,Ti; de maneira que sua aplicação como uma alternativa às pastilhas TLD-100 na dosimetria de feixes de elétrons em radioterapia é viável e apresenta a sensibilidade à radiação de elétrons significativamente mais alta como principal vantagem.
The assessment of the performance of CaSO4:Dy thermoluminescent detectors produced by IPEN in the dosimetry of clinical electron beams aims to propose an alternative to the LiF:Mg,Ti commercial dosimeters (TLD-100) largely applied in radiation therapy. The two types of thermoluminescent dosimeters were characterised with the use of PMMA, RMI-457 type solid water and water phantoms in radiation fields of 4, 6, 9, 12 and 16 MeV electrons of nominal energies in which the dose-response curves were obtained and the surface and depth doses were determined. The thermoluminescent response dependency with the electron nominal energies and the applied phantom were studied. The CaSO4:Dy presented the same behaviour than the LiF:Mg,Ti in such a way that its application as an alternative to the TLD-100 pellets in the radiation therapy dosimetry of electron beams is viable and presents the significantly higher sensitivity to the electron radiation as its main advantage.
APA, Harvard, Vancouver, ISO, and other styles
6

Salmazo, Giovana Oliveira [UNESP]. "Estudo geocronológico de sedimentos correlatos à Formação Rio Claro." Universidade Estadual Paulista (UNESP), 2015. http://hdl.handle.net/11449/144084.

Full text
Abstract:
Made available in DSpace on 2016-09-27T13:40:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-20. Added 1 bitstream(s) on 2016-09-27T13:45:16Z : No. of bitstreams: 1 000868818.pdf: 3357051 bytes, checksum: d7903302919e833af9096dc561273e92 (MD5)
A idade da Formação Rio Claro até o presente momento tem sido alvo de controvérsias, pois não havia sido realizado um estudo geocronológico preciso e direto. Com a utilização do quartzo como dosímetro comum aos sedimentos da formação, avaliou-se por termoluminescência que a sedimentação da Formação Rio Claro ocorreu no Pleistoceno Superior. Para garantir a veracidade dos resultados obtidos, buscou-se aprimorar a técnica de dosimetria utilizada pelo laboratório. A caracterização das propriedades luminescentes dos grãos de quartzo dos sedimentos mostrou que o sinal LOE (luminescência opticamente estimulada) de todas as amostras estava saturado e algumas das amostras também apresentavam saturação do sinal TL (termoluminescência). A saturação se deve à origem fluvial dos sedimentos que inviabilizou o desvanecimento dos sinais de TL e LOE no ato da deposição. As amostras DS 01 e DS 06 não apresentaram saturação do sinal TL. Idades TL foram obtidas para ambas possibilitando a determinação do período de deposição dos sedimentos. Os resultados obtidos mostraram que o quartzo possui dois estágios de saturação. A datação por TL utiliza apenas o primeiro estágio de saturação, pois neste a irradiação de laboratório reproduz satisfatoriamente o mesmo comportamento do sinal TL gerado na natureza
The sedimentary deposition range of Rio Claro Formation until now remained among controversies because it was not done a precise and direct geochronological study. With the use of quartz as a common dosimeter of sedimentary formation, it was possible to evaluate using thermoluminescence that sedimentation occurred in Upper Pleistocene. To ensure the accuracy of the results obtained, It sought to improve the dosimetric technique used by the laboratory. The characterization of luminescent properties of the sedimentary quartz grains showed that OSL signal of all samples was saturated and some sample showed TL signal saturated too. Saturation is due to the sediments have fluvial origin. TL signal of the samples DS 01 and DS 06 it was saturated. The TL age was obtained for both. A study related to technical limitation TL showed that the quartz has two stages of saturation. The TL dating uses only the first stage of saturation because laboratory irradiation satisfactorily reproduces the same TL signal behavior generated in nature
APA, Harvard, Vancouver, ISO, and other styles
7

Lucia, de Oliveira Fernanda. "Avaliação da dose em radioterapia crânio-espinhal para meduloblastoma." Universidade Federal de Pernambuco, 2008. https://repositorio.ufpe.br/handle/123456789/9813.

Full text
Abstract:
Made available in DSpace on 2014-06-12T23:16:16Z (GMT). No. of bitstreams: 2 arquivo8657_1.pdf: 1359998 bytes, checksum: 4930af050e72970d101a75c5ac9f55b2 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008
Conselho Nacional de Desenvolvimento Científico e Tecnológico
O Meduloblastoma é um Tumor Neuroectodermal Primitivo da Fossa Posterior (PNET-FP), sendo biologicamente agressivo com predominância entre as faixas etárias de 5 a 10 anos e de 24 a 34 anos. O tratamento é realizado de maneira conjunta pelo cirurgião, neurologista e o radioterapeuta. Quando possível, é iniciado com cirurgia para máxima remoção do tumor, seguido da quimioterapia e da radioterapia. A radioterapia é realizada através da irradiação crânio-espinhal, com doses que variam de 30 a 35 Gy, seguido de um reforço na fossa posterior. Para esta prática, diversas técnicas têm sido propostas com a combinação dos campos e distribuição das doses, mas problemas com a distribuição da dose podem ocorrer durante a irradiação, devido à aplicação não coplanar dos campos. Isso pode resultar em sub ou superdosagem na junção dos campos, acarretando recidivas da doença, reduzindo a sobrevida do paciente ou gerando complicações tardias nos órgãos que estão no campo de irradiação ou nas regiões de contorno. Estas complicações, cujos fatores principais são as doses e a área irradiada, podem ser minimizadas através de aplicação de técnicas mais otimizadas. Neste trabalho foram avaliadas as doses devido à irradiação crânio-espinhal em pacientes com meduloblastoma através de duas técnicas: Técnica de meio-feixe e Campo angulado, com quatro planejamentos diferentes. Tais planejamentos foram realizados aplicando a Técnica de meio-feixe, Campo angulado, Campo angulado com gap móvel e Campo angulado sem gap móvel, isto viabiliza uma Intercomparação Dosimétrica do nível III, o que torna possível verificar as diferenças entre técnicas e equipamentos, conforme recomendação da Agência Internacional de Energia Atômica (AIEA) no Safety Report Nº 17. Para este fim, foram utilizados um simulador antropomórfico, ALDERSONRANDON, e dosímetros termoluminescentes. Os resultados obtidos foram comparados entre si e observou-se que os valores das doses avaliadas variaram de 17 a 23% nos campos craniais e de 10 a 36% nos campos espinhais. Estes resultados sugerem a necessidade de realização de uma intercomparação dosimétrica do nível II para rastrear possíveis causas de tais diferenças entre dose planejada e dose medida para cada planejamento, visando à melhoria da qualidade da radioterapia
APA, Harvard, Vancouver, ISO, and other styles
8

ROSA, LUIZ A. R. da. "Termoluminescencia do LiF: Mg, Ti entre 66 e 315 K." reponame:Repositório Institucional do IPEN, 1989. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10259.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:36:38Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T13:59:10Z (GMT). No. of bitstreams: 1 01821.pdf: 4038166 bytes, checksum: ede612636a13b46e2d052cfc50e01907 (MD5)
Tese (Doutoramento)
IPEN/T
Instituto de Fisica, Universidade de Sao Paulo - IF/USP
APA, Harvard, Vancouver, ISO, and other styles
9

Wigren, Sonja. "Sörmländsk bronsåldersbygd : en studie av tidiga centrumbildningar daterade med termoluminescens." Doctoral thesis, Stockholms universitet, Humanistiska fakulteten, 1987. http://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-84341.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Shammas, Gabriel Issa Jabra. ""Simulação semi-empírica da resposta termoluminescente sob diferentes geometrias de filtro"." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-01062007-135709/.

Full text
Abstract:
Muitos materiais termoluminescentes têm sido desenvolvidos e utilizados para a monitoração individual externa de fótons, mas nenhum tem todas as características desejadas sozinho. Estas características incluem robustez, alta sensibilidade, independência de resposta quanto à energia do fóton, larga faixa de detecção de energia, boa reprodutibilidade, evanescência pequena e curva de emissão termoluminescente simples, com picos abaixo de 150oC. O dosímetro de sulfato de cálcio dopado com disprósio CaSO4:Dy) tem sido usado por muitos laboratórios, principalmente no Brasil e na Índia. Outro fósforo interessante é o fluoreto de cálcio (CaF2). As vantagens destes fósforos começam a ser mais requisitadas e suas desvantagens mais aparentes, no mercado globalizado mais e mais competitivo. Estes fósforos são utilizados em monitoração de área e ambiental devido à sua maior sensibilidade do que outros fósforos, como o LiF:Mg. A sua maior desvantagem é a forte dependência energética da resposta, que deve ser corrigida para suas aplicações em campo, onde o fóton é desconhecido a priori. Um modo interessante de fazer esta correção numa incidência ortogonal da radiação no fósforo é a interposição de um filtro plano vazado entre o feixe e o fósforo. Com o objetivo de reduzir a dependência energética sob incidência em qualquer ângulo, reduzindo a incerteza de medição da dose em campo também, este trabalho apresenta um estudo de simulação em geometrias de filtro esféricas. Foram simuladas irradiações de fótons com raios gama do cobalto 60, com raios-X de 33, 48 e 118 keV, em vários ângulos de incidência de zero a noventa graus. Estas simulações computacionais semi-empíricas, utilizando diferenças finitas em três dimensões, foram feitas em coordenadas esféricas. Os resultados indicaram as melhores espessuras e larguras para a otimização da correção da dependência energética.
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproductibility, small fading and simple glow curve with peaks above 150oC. Calcium Sulfate Dysprosium doped (CaSO4:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF2). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the field, where photon radiation is unknown a priori. An interesting way do make this correction in orthogonal incidence of the radiation on the phosphor is to interject a plane leaked filter between the beam and the phosphor. In order to reduce the energetic dependence on any incidence angle, reducing the field dose measurement uncertainty too, this work presents a simulation study on spherical filter geometries. It was simulated photon irradiations with Gamma rays of 60Co and x-rays of 33; 48 and 118 keV, on many incidence angles from zero to ninety degrees. These semi-empirical computational simulations using finite differences in three dimensions were done in spherical coordinates. The results pointed out the best filter thicknesses and widths, in order to optimize the correction on energetic dependence.
APA, Harvard, Vancouver, ISO, and other styles
11

SHAMMAS, GABRIEL I. J. "Simulação semi-empírica da resposta termoluminescente sob diferentes geometrias de filtro." reponame:Repositório Institucional do IPEN, 2006. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11484.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:52:24Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T14:01:17Z (GMT). No. of bitstreams: 0
Dissertação (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
12

Poliana, Souza da Silva Carla. "Estudo da resposta de cristais de quartzo natural para dosimetria termoluminescente." Universidade Federal de Pernambuco, 2005. https://repositorio.ufpe.br/handle/123456789/9911.

Full text
Abstract:
Made available in DSpace on 2014-06-12T23:16:49Z (GMT). No. of bitstreams: 2 arquivo9065_1.pdf: 3020789 bytes, checksum: 53d6ed5cd0e9ea4c3717cf752eec6708 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005
Nos últimos anos, muitos estudos vêm sendo realizados com o objetivo de caracterizar e/ou desenvolver materiais com propriedades termoluminescentes (TL) para fins de dosimetria das radiações ionizantes. Nesse sentido, este trabalho foi realizado com o objetivo de caracterizar as propriedades termoluminescentes de cristais de quartzo natural visando sua aplicação em dosimetria de radiação X e gama. Os cristais de quartzo utilizados são originários de jazidas das seguintes regiões do país: Batatal (MG), Governador Valadares (MG), Palmeira (CE), Pium (TO) e Solonópolis (CE), cujas concentrações de impurezas e coordenadas geográficas são conhecidas. As amostras foram orientadas paralelas ao eixo cristalográfico [0001] e cortadas nas dimensões de 5x5x1 mm. Inicialmente foi efetuado o estudo da curva de emissão TL destes cristais (glow curve), sendo observado que apenas as amostras de Solonópolis e Batatal apresentam sinal TL na região de 200 a 320°C para faixa de doses de 1,0 a 20,0mGy. Para compreender este comportamento, foram efetuadas análises espectroscópicas de Infravermelho (IV) e Ultravioleta visível (UV-VIS). Em seguida as amostras de Solonópolis e Batatal foram irradiadas em uma fonte 137Cs a fim de determinar a repetibilidade e a reprodutibilidade da sua resposta termoluminescente na região de 160 a 320°C (433 a 593K). Os resultados mostram uma variação menor ou igual que 3%. A resposta TL em função da dose de radiação foi avaliada para feixes de radiação gama do 60C e do 137Cs e para feixes de raios-X com energias entre 16 a 65Kev. Os resultados mostram uma resposta linear em função da dose e que a sensibilidade das amostras de quartzo de Solonópolis e Batatal é maior que do TLD-100. A grande sensibilidade desses cristais foi discutida em função da natureza dos centros de defeitos relacionados ao alumínio substitucional. O estudo do desvanecimento da resposta TL à temperatura ambiente do pico entre 160 e 320°C foi realizado para um período de 75 dias. Nesse período o sinal TL não apresentou perdas significativas (~3%)
APA, Harvard, Vancouver, ISO, and other styles
13

Ruana, Vidal do Nascimento Samira. "Dosimetria termoluminescente do quartzo natural de Solonópole (CE) para aplicação em radiodiagnóstico." Universidade Federal de Pernambuco, 2010. https://repositorio.ufpe.br/handle/123456789/9190.

Full text
Abstract:
Made available in DSpace on 2014-06-12T23:13:33Z (GMT). No. of bitstreams: 2 arquivo2660_1.pdf: 3852471 bytes, checksum: 9008e833bfe91f8c45557c9640cbe743 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Dosímetros termoluminescentes (TL) são muito empregados para medir doses de radiação ionizante, sobretudo em dosimetria clínica e ambiental. Diversas pesquisas têm sido feitas buscando desenvolver materiais TL mais sensíveis para aplicação na dosimetria de baixas doses. Neste contexto, trabalhos recentes mostraram a possibilidade de medir doses da ordem de 0,1 mGy utilizando o quartzo natural de Solonópole (CE) após um procedimento de sensibilização com tratamentos térmicos e altas doses de radiação gama. Entretanto, para que este material possa ser utilizado como dosímetro TL é necessário estudar de forma sistemática suas propriedades dosimétricas. Assim, este trabalho tem como objetivo estudar as propriedades dosimétricas do quartzo natural de Solonópole (CE) sensibilizado e investigar sua aplicabilidade como dosímetro TL em exames de radiodiagnóstico convencional. Para isso, foram produzidos 95 discos de quartzo sensibilizado (6 mm x 1 mm). A variação da reprodutibilidade da resposta TL foi avaliada a partir de cinco irradiações com 10 mGy com uma fonte de raios gama de 137Cs. Para investigar a estabilidade da resposta TL deste material, os lotes foram irradiados nas mesmas condições e armazenados na ausência de luz por até 120 dias. Para estudar o comportamento da resposta TL em função do kerma no ar, as amostras foram irradiadas com raios gama de uma fonte de 137Cs com valores de kerma no ar entre 0,01 e 100 mGy. A dependência energética foi determinada a partir dos coeficientes angulares das curvas de calibração obtidas com feixes de raios X de espectro estreito (de 16 a 118 keV), e raios gama de 137Cs e 60Co. Por sua vez, a dependência angular foi determinada irradiando as amostras com feixes de raios X para ângulos entre -90° e 90°. Posteriormente, as amostras de quartzo e os dosímetros TLD-100 foram posicionados sobre um simulador antropomórfico de tórax, no centro geométrico do feixe de raios X. Estas medidas foram utilizadas para determinar o kerma no ar na superfície de entrada. O estudo das propriedades dosimétricas permitiu observar que as amostras de quartzo apresentaram reprodutibilidade, estabilidade da resposta TL e dependência angular equivalentes àquelas do TLD-100. A partir das curvas de resposta TL em função do kerma no ar, constatou-se que a resposta TL do quartzo é linear para doses entre 0,01 e 100 mGy. Além disso, observou-se que as amostras de quartzo permitiam determinar valores de kerma no ar três vezes mais baixos quando comparado aos do TLD-100. A dependência energética máxima destas amostras foi três vezes maior que a do TLD-100 e não há dependência angular para o intervalo de -45° a 45°. A sensibilidade relativa à do TLD-100 destas amostras varia entre 2 e 5 de acordo com a energia da radiação incidente. Ao utilizar estas amostras para a determinação do kerma no ar na superfície de entrada, elas apresentaram boa equivalência com os dados encontrados com o TLD-100. Conclui-se que o quartzo sensibilizado de Solonópole caracterizado pode ser empregado de maneira confiável para medir o kerma no ar na superfície de entrada em exames de raios X de tórax
APA, Harvard, Vancouver, ISO, and other styles
14

Santos, Lindomar Soares dos. "Implementação de um sistema dosimétrico termoluminescente para utilização em dosimetria in vivo em teleterapia com feixes de fótons de energia alta." Universidade de São Paulo, 2007. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-12052008-150030/.

Full text
Abstract:
A dosimetria in vivo é a verificação final da dose real administrada ao paciente e tornou-se atualmente necessária devido ao aumento da complexidade e da sofisticaçã das técnicas radioterápicas. A finalidade deste trabalho foi apresentar, verificar e avaliar alguns procedimentos básicos, práticos e viáveis para a implementação da dosimetria in vivo com dosímetros termoluminescentes na verificação de dose em um serviço de radioterapia. Para o estabelecimento do sistema dosimétrico termoluminescente, alguns testes e medições foram realizados, incluindo o procedimento de inicialização, a determinação da homogeneidade do grupo de dosímetros, a determinação do fator de correção individual de cada dosímetro, a determinação da faixa de linearidade do sistema e do coeficiente de calibração. Medições em um objeto simulador antropomórfico foram realizadas para garantir que os métodos utilizados são satisfatórios antes que estes fossem usados para medições em pacientes. Medições de dose em um paciente foram feitas em um tratamento de câncer de próstata. A metodologia proposta pode ser usada como parte de um programa de garantia de qualidade em um serviço de radioterapia.
In vivo dosimetry is the ultimate check of the actual dose delivered to an individual patient and has become a procedure actually necessary due to increasing complexity and sophistication of radiotherapy techniques. The purpose of the present work was to present, verify and evaluate some basic, practical and viable procedures for the implementation of in vivo dosimetry with thermoluminescent dosimeters for patient dose verification at a radiotherapy service. For the setting up of the thermoluminescent dosimetric system, several tests and measurements were carried out including the initialisation procedure, the determination of the batch homogeneity, the determination of individual correction factor of each dosimeter, the determination of linearity range of the system and its calibration coefficients. Anthropomorphic phantom measurements were taken to ensure that the methods are satisfactory before they are used for patients measurements. Patient dose measurements were carried out in a prostate cancer treatment. The proposed methodology can be used as a part of a quality assurance program in a radiotherapy service.
APA, Harvard, Vancouver, ISO, and other styles
15

POTIENS, JUNIOR ADEMAR J. "Caracterizacao do fosforo termoluminescente MgBsub4Osub7:Dy para aplicacao na deteccao de neutrons termicos." reponame:Repositório Institucional do IPEN, 1992. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10307.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:37:08Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T13:56:46Z (GMT). No. of bitstreams: 1 01911.pdf: 1009127 bytes, checksum: 60028ce956b2d5251629899c29bd2c3a (MD5)
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
16

Rojas, Seila Silva. "Propriedades térmicas e estruturais do sistema CaB4O7-CaB2O4 visando o desenvolvimento de dosímetro termoluminescente." Universidade de São Paulo, 2005. http://www.teses.usp.br/teses/disponiveis/76/76132/tde-19092007-114452/.

Full text
Abstract:
Vidros boratos contendo óxidos modificadores vêm sendo estudados por apresentarem um número atômico efetivo próximo ao do tecido humano, o que os tornam materiais interessantes para o desenvolvimento de dosímetros termoluminescentes. O objetivo deste trabalho foi estudar as propriedades térmicas e estruturais do sistema xCaB4O7-(100-x)CaB2O4, com x variando de 0 a 100 % em massa. As amostras sem dopantes foram previamente estudadas a fim de determinar uma composição que apresentasse a melhor resposta termoluminescente (TL) para a inclusão do íon Dy como dopante e Li como co-dopante, aumentando a eficiência TL da mesma. Pelo método de fusão e moldagem, foram obtidos amostras vítreas e vitrocerâmicas. A fase cristalina presente nas amostras vitrocerâmicas foi determinada por difratometria de raios X e identificada como fase única CaB2O4. A composição vitrocerâmica 20CaB4 (% em massa) apresentou a melhor resposta TL, sendo dopada com Dy e co-dopada com Li para o estudo das propriedades dosimétricas. Este estudo mostrou uma resposta linear num intervalo de 5 a 70 minutos de exposição à radiação ultravioleta e uma boa reprodutibilidade do sinal TL provando ser um material promissor para a utilização em dosimetria pessoal e clínica.
Borate glasses containing modified oxides have been studied on account of their effective atomic number close to that of the human tissue, what makes them interesting materials for the development of the thermoluminescent dosimeters. The purpose of this work was to study the thermal and structure properties of the xCaB4O7-(100-x)CaB2O4 system with x ranging from 0 to 100 wt%. The undoped samples were previously studied in order to determine a composition that would present a better thermoluminescent response for the incluision of the Dy íon as dopant and Li as co-dopant, thus increasing its TL efficiency. By the melting/molding method, the glass-ceramic samples was determined by the X-ray difractometry and identified as a unique CaB2O4 phase. The glass-ceramic 20 CaB2O4 (wt%) composition presented the best TL response being doped with Dy and co-doped with Li for the study of the dosimetric properties. This study has shown a linear response within an interval of 5 to 70 minutes of exposure to the UV radiation and good reproducibility of the TL signal, thus proving to be a promising material for using in the personal and clinical dosimetry.
APA, Harvard, Vancouver, ISO, and other styles
17

SILVA, MARIA R. O. de O. da. "Influencia da microestrutura e composicao de alumina na termoluminescencia visando sua aplicacao em dosimetria." reponame:Repositório Institucional do IPEN, 2001. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10974.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:46:19Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T14:01:29Z (GMT). No. of bitstreams: 1 07920.pdf: 4978186 bytes, checksum: 871f8094f14df81094eb8a5d8c1a8d6b (MD5)
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
18

Umiji, Reinaldo Massayuki [UNESP]. "Datação de Cerâmicas Arqueológicas do Noroeste Paulista pelo Método da Termoluminescência." Universidade Estadual Paulista (UNESP), 2014. http://hdl.handle.net/11449/113848.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-10Bitstream added on 2015-01-26T13:30:46Z : No. of bitstreams: 1 000801915.pdf: 785680 bytes, checksum: dfd2ebc069dedd86e2be9dd843c4c15f (MD5)
A inserção das ciências físicas tem proporcionado grande contribuição aos estudos arqueológicos com as mais distintas técnicas de datação, permitindo que os mais variados tipos de materiais encontrados possam ser datados e, consequentemente, estabelecer a relação entre as várias culturas e a sua cronologia. A técnica de datação por Termoluminescência considera que materiais cerâmicos apresentam na sua composição cristais termoluminescentes que, ao ficarem expostos à radiação ionizante, devido à presença dos radionuclídeos e os raios cósmicos, acumulam energia nos chamados níveis metaestáveis, e quando aquecido a intensidade termoluminescente emitida pela amostra é proporcional ao tempo que ficou exposto a radiação. Assim, o presente estudo trata da datação absoluta de fragmentos cerâmicos provenientes dos Sítios Arqueológicos Aguinha, Célia Maria, Pernilongo, Ragil, Turvo III e Turvo V, aplicando a datação por Termoluminescência (TL). Como consequência deste estudo forneceremos subsídios para os arqueólogos estabelecerem uma cronologia para ocupações, comparando os resultados presentes com datações já realizadas. Comparando os resultados obtidos neste trabalho, com os já realizados observamos que o fragmento do sítio Ragil, mostrou resultados que não confirma interpretação arqueológica. No entanto os demais fragmentos permitiram que os mesmos confirmassem a época de ocupação
The insertion of the physical sciences has provided great contribution to archaeology with the most distinct studies dating techniques, allowing all kinds of materials can be found dated and consequently establish the relationship between cultures and their chronology. The thermoluminescence dating technique considers that pottery materials have in their composition thermoluminescent crystals that were exposed to ionizing radiation, due to the presence of cosmic rays and radionuclides, which accumulate this energy in the so called metastable levels, and when heated thermoluminescence intensity emitted by the sample is proportional to the time that it has been exposed to the radiation. Thus, the present study deals with the absolute dating of ceramic fragments from the Archaeological Sites Aguinha, Célia Maria, Pernilongo, Ragil, Turvo III and V, by applying dating by Thermoluminescence (TL). As a consequence, this study well provide subsidies to establish a chronology for archaeological occupations, comparing the present results with dating already performed. Comparing the results obtained in this work, we observe that already carried the fragment Site Ragil, results showed that neither confirms archaeological interpretation. However the remaining fragments allowed even confirm the time of occupation
APA, Harvard, Vancouver, ISO, and other styles
19

Matsushima, Luciana Cardoso. "Avaliação da resposta de detectores termoluminescentes na dosimetria de feixes clínicos utilizando diferentes objetos simuladores." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-12082011-103710/.

Full text
Abstract:
A radioterapia é uma das três principais modalidades de tratamento utilizadas no tratamento de doenças malignas, como o câncer; as duas outras são a quimioterapia e a radiocirurgia. Em contraste com outras especialidades médicas que necessitam principalmente de conhecimento clínico e da experiência de especialistas, a radioterapia, com o uso da radiação ionizante no tratamento do câncer, necessita de grandes investimentos em tecnologias modernas e do esforço colaborativo de diversos profissionais que contribuem para o sucesso do tratamento. Na área de dosimetria clínica, uma calibração eficiente e precisa do feixe de radiação garante o conhecimento da dose fornecida ao paciente, assegurando, portanto, o sucesso do tratamento radioterápico. Este trabalho tem por objetivo o estudo comparativo da resposta termoluminescente dos dosímetros de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN (6 mm de diâmetro e 0,8 mm de espessura) com a resposta dos dosímetros de fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti com 3,15 x 3,15 x 0,9 mm3) na dosimetria de feixes clínicos de fótons (6 e 15 MV) e elétrons (6 e 9 MeV) utilizando objetos simuladores de água sólida (RMI-457), água e PMMA. Foram obtidas as curvas de dose-resposta para a radiação gama do cobalto-60 (60Co) no ar e em condições de equilíbrio eletrônico (placa de PMMA), e para elétrons e fótons clínicos nas profundidades de dose máxima. Foi avaliada também a sensibilidade dos dosímetros termoluminescentes e determinada a reprodutibilidade da resposta e a eficiência intrínseca para os diferentes tipos de simuladores e energias de radiação estudadas. Os resultados obtidos indicam que a principal vantagem do dosímetro de CaSO4:Dy é a sua maior sensibilidade para as doses de radiação avaliadas para os feixes do 60Co, fótons e elétrons, representando, portanto, uma alternativa viável para a aplicação em dosimetria nos setores de radioterapia.
Radiotherapy is one of the three principal treatment modalities used in the treatment of malignant diseases such as cancer, the other two are chemotherapy and radiosurgery. In contrast to other medical specialties that rely mainly on the clinical knowledge and experience of medical specialists, radiotherapy, with its use of ionizing radiation in treatment of cancer, relies heavily on modern technology and the collaborative efforts of several professionals whose coordinated team approach greatly influences the outcome of the treatment. In the area of clinical dosimetry, an efficient and accurate calibration of the radiation beam ensures knowledge of the radiation dose delivered to the patient, allowing thus the success of radiotherapy. This study aims to compare the thermoluminescent response of calcium sulphate doped with dysprosium (CaSO4:Dy) dosimeters produced by IPEN (6 mm in diameter and 0,8 mm tick) with the response of lithium fluoride (3,15 x 3,15 x 0,9 mm3) doped with magnesium and titanium (LiF:Mg,Ti) in dosimetry of clinical photons (6 and 15 MV) and electrons beams (6 and 9 MeV) using solid water (RMI-457), water and PMMA phantoms. Initially, the dose-response curves were obtained for irradiation in cobalt-60 gamma radiation source in air (PMMA plates) and under electronic equilibrium conditions and for clinical electrons and photons beams at depth of maximum dose. The sensitivities of the thermoluminescent dosimeters were also evaluated and the values of their reproducibilities and intrinsic efficiency were determined for the response to differents types of phantoms and radiation energy. The obtained results indicate that the main advantage of CaSO4:Dy dosimeters is the enhanced sensitivity to radiation doses measured for 60Co, photons and electrons beams, thus representing a viable alternative for application in dosimetry in the radiotherapy area.
APA, Harvard, Vancouver, ISO, and other styles
20

Bravim, Amanda. "Avaliação de dosímetros termoluminescentes empregando objetos simuladores equivalentes à água para aplicação na dosimetria de feixes clínicos de elétrons." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-20062011-101414/.

Full text
Abstract:
A dosimetria em Radioterapia prevê a calibração do feixe de radiação e a dosimetria de rotina para controle de qualidade, pois o seu principal objetivo é determinar, com maior precisão, a dose absorvida pelo tumor. Este trabalho tem como objetivo avaliar o comportamento de três dosímetros termoluminescentes na dosimetria de feixes clínicos de elétrons. O desempenho de detectores de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN foi comparado com o de dois dosímetros comercialmente disponíveis pela Harshaw, ambos denominados TLD-100, porém com dimensões distintas. Os dosímetros foram caracterizados com a utilização de objetos simuladores de água, água sólida RMI-457 e PMMA em campos de radiação de elétrons de 4, 6, 9, 12 e 16 MeV. Também foram realizadas medidas em feixes de fótons de 6 e 15 MV (2 e 5 MeV) apenas para comparação de resultados. As curvas de dose-resposta foram obtidas para a radiação gama do 60Co no ar e em condições de equilíbrio eletrônico e para feixes clínicos de fótons e elétrons nas profundidades de máxima dose. A sensibilidade, a reprodutibilidade, a eficiência intrínseca e a dependência energética dos dosímetros termoluminescentes foram estudadas. O CaSO4:Dy apresentou comportamento semelhante ao dos TLD-100 com uma vantagem em relação à sensibilidade para os feixes e doses de radiação estudados. Sendo assim, o dosímetro produzido pelo IPEN pode ser considerado uma nova alternativa para a dosimetria nos departamentos de Radioterapia.
The dosimetry in Radiotherapy provides the calibration of the radiation beam as well as the quality control of the dose in the clinical routine. Its main objective is to determine with greater accuracy the dose absorbed by the tumor. This study aimed to evaluate the behavior of three thermoluminescent dosimeters for the clinical electron beam dosimetry. The performance of the calcium sulfate detector doped with dysprosium (CaSO4: Dy) produced by IPEN was compared with two dosimeters commercially available by Harshaw. Both are named TLD-100, however they differ in their dimensions. The dosimeters were evaluated using water, solid water (RMI-457) and PMMA phantoms in different exposure fields for 4, 6, 9, 12 and 16 MeV electron beam energies. It was also performed measurements in photon beams of 6 and 15 MV (2 and 5 MeV) only for comparison. The dose-response curves were obtained for the 60Co gamma radiation in air and under conditions of electronic equilibrium, both for clinical beam of photons and electrons in maximum dose depths. The sensitivity, reproducibility, intrinsic efficiency and energy dependence response of dosimeters were studied. The CaSO4: Dy showed the same behavior of TLD-100, demonstrating only an advantage in the sensitivity to the beams and radiation doses studied. Thus, the dosimeter produced by IPEN can be considered a new alternative for dosimetry in Radiotherapy departments.
APA, Harvard, Vancouver, ISO, and other styles
21

Ferreira, Marcela Felix Chaves. "Implementação de uma análise computadorizada da curva de emissão termoluminescente e aplicação em dosimetria clínica." Universidade de São Paulo, 2018. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-04062018-101047/.

Full text
Abstract:
Nas décadas de 1960 e 1970, as primeiras investigações de dosímetros termoluminescentes (TLD), especificamente, os picos dosimétricos, rapidamente revelaram um número surpreendente de fenômenos que poderiam estar diretamente relacionados à densidade de ionização. Um pouco mais tarde, nos anos 80 e no início dos anos 90, a radiação aparentemente desconectada induziu fenômenos que foram descobertos em outros sistemas baseados em fluoreto de lítio (LiF). A última década, no entanto, testemunhou o surgimento de vários modelos, encabeçado através de uma compreensão mais profunda dos mecanismos TL subjacentes, bem como na modelagem micro dosimétrica e especificamente desenvolvida para explicar fenômenos de densidade de ionização. Muitas aplicações em radioterapia fornecem níveis de dose de radiação superiores a 1 Gy, porém em radiodiagnóstico estão na faixa de alguns mGy, e níveis muito altos de precisão são necessárias para promover o tratamento ideal. Isto exige uma atenção muito cuidadosa aos protocolos de medição altamente detalhados, bem como à calibração demorada de todos os TLDs para corrigir a não-linearidade da resposta à dose. Essas propriedades podem variar de lote para lote e também podem ser uma função da exposição à radiação, do aquecimento e histórico de manuseio. Deste modo, mesmo com excelentes avanços nos estudos do TLD com relação aos tratamentos térmicos e às formas de análise da curva de emissão TL, é necessário continuar os estudos a fim de possibilitar uma melhor utilização desta técnica na clínica. Uma análise computadorizada da curva de emissão (CGCA do inglês, computadorized glow curve analisys) foi implementada utilizando dados provenientes do software WinREMS de dosímetros TL que absorvem e armazenam a energia da radiação ionizante, reemitida na forma de fóton na região do ultravioleta visível. A luz emitida é, então, detectada por uma fotomultiplicadora e correlacionada à dose absorvida recebida pelo material. Os picos de emissão foram ajustados por meio de um algoritmo no programa MATLAB adotando-se o modelo de cinética de primeira ordem. O material testado foi o LiF:Mg,Ti (fluoreto de lítio dopado com magnésio e titânio) da marca Harshaw e a qualidade do ajuste foi determinada por um parâmetro chamado figura de mérito (FOM - do inglês, figure of merit). O menor FOM obtido para o grupo de dosímetros foi de 1,04 % e o maior foi de 9,79 %. Também foi avaliada a dose mínima detectável, utilizando o parâmetro que apresentou melhor desempenho, segundo a homogeneidade do grupo de dosímetros. O valor médio de dose mínima apresentado foi 28 µGy. Os resultados de reprodutibilidade, índice de variabilidade do detector (DVI - do inglês, device variability index) foi 14,01 %, que pode ser explicado pelo alto número de dosímetros no lote. Então, com a diminuição do tempo de preparo do dosímetro e com a análise computadorizada da curva de emissão, a utilização clínica do TLD torna-se mais viável, visto que não houve interferência na sensibilidade do dosímetro. Apesar de a reprodutibilidade ter sido a cima do esperado, é indicado uma correção individual para cada dosímetro e o descarte daqueles que apresentarem valores mais discrepantes comparado ao lote.
In the decades of 1960 and 1970, the first investigations of termoluminescentes dosimeters (TLD), specifically, the dosimetric peaks quickly revealed a surprising number of phenomena that could be directly related to the density of ionization. A little later, in the years 80 and 90 at the beginning of the year, seemingly disconnected radiation induced phenomena were discovered on other systems based on lithium fluoride (LiF). The last decade, however, has witnessed the emergence of several models, spearheaded through a deeper understanding of the underlying TL mechanisms as well as in modeling specifically developed for microdosimetric and explain phenomena of ionization density. Many applications in radiation oncology provide levels of radiation dose in excess of 1 Gy, however in diagnostic radiology are in the range of a few mGy, and very high levels of precision are necessary to promote the ideal treatment. This requires careful attention to the highly detailed measurement protocols, as well as the time-consuming calibration of all TLDs to correct the non-linearity of dose-response. These properties can vary from batch to batch, and can also be a function of exposure to radiation, heating and handling history. In this way, even with excellent advances in the studies of the TLD for the heat treatment and the ways of issuing TL curve analysis, it is necessary to continue studies in order to enable a better use of this technique in the clinic. A computerized analysis of the emission curve (CGCA computadorized glow curve analysis) was implemented using data from the WinREMS software of TL dosimeters that absorb and store energy from ionizing radiation, reissued in the form of photon in the visible ultraviolet. The light emitted is then detected by a photomultiplier and correlated to the absorbed dose received by the material. The emission peaks were adjusted by means of an algorithm in MATLAB program by adopting the model of first-order kinetics. The material tested was the LiF: Mg, Ti (lithium fluoride doped with magnesium and titanium) brand Harshaw and the quality of the fit was determined by a parameter called figure of merit (FOM- figure of merit). The smallest FOM obtained for the group of dosimeters was 1.04% and the highest was 9.79%. Also minimum detectable dose was evaluated, using the parameter that showed better performance, according to the homogeneity of the Group of dosimeters. The average value of minimum dose presented was 28 µGy. The results of reproducibility, index of variability of the detector (DVI-English, device variability index) was 14.01%, which can be explained by the high number of dosimeters in the batch. Then, with the decrease in the time of preparation of the dosimeter and the computerized analysis of the emission curve, the clinical use of the TLD becomes more viable, since there was no interference on sensitivity of the dosimeter. Although the reproducibility have been above expectations, indicated a single correction for each badge and the disposal of those who submit more discrepant values compared to the batch.
APA, Harvard, Vancouver, ISO, and other styles
22

Santos, Cristiane Nascimento. "Estudo de vidros metafosfatos do sistema KPO3 Al(PO3)3 e sua aplicação em dosimetria termoluminescente." Universidade de São Paulo, 2003. http://www.teses.usp.br/teses/disponiveis/76/76132/tde-09122013-110749/.

Full text
Abstract:
Vidros com composição de aluminofosfato vêm sendo estudados por apresentarem elevada durabilidade química. O objetivo do presente trabalho foi estudar as propriedades térmicas e estruturais do sistema vítreo xKPO3 - (100-x)Al(PO3)3, para x = 10, 30 e 50 (% em mol), a fim de determinarmos uma composição que apresentasse uma boa resposta termoluminescente (TL) quando dopada com íons de manganês. As matrizes vítreas não dopadas apresentaram uma boa estabilidade vítrea frente a devitrificação. As fases cristalizadas no sistema foram determinadas por difração de raios X e espectroscopia micro-Raman como KAIP2O7 e AI(PO3)3. A composição KAI(PO3)4 (x = 50 %) apresentou elevada durabilidade química e o menor ponto de fusão, o que facilitou o processo de preparação. Essa composição foi então utilizada para as dopagens com íons de manganês. A composição com 1,0 % em mol de MnO2 apresentou a melhor resposta TL. As propriedades dosimétricas estudadas mostraram que o vidro possui uma resposta linear para raios X no intervalo de dose de 2 mGy a 80 Gy, podendo então ser utilizado em dosimetria clínica e pessoal
Aluminophosphate glasses have been studied because of their good chemical resistance. The main purpose of this work was to investigate the structural and thermal properties of glasses in the system xKPO3 - (100-x)AI(PO3)3, with x = 10, 30 e 50 (mol %). The goal was to determine a composition which provided a good thermoluminescence response (TL) when doped with manganese ions. The undoped vitreous matrixes showed a good thermal stability against devitrification. The crystalline phases were identified by X ray diffraction and micro-Raman spectroscopy as KAIP2O7 and Al(PO3)3. The composition KAI(PO3)4 (x = 50 %) showed high chemical resistance and lower melting point. This composition was used for doping with manganese ions. The composition of 1,0 mol % of MnO2 showed the best TL response. The dosimetric properties showed that this glass has a linear response for X-rays in the dose interval of 2 mGy to 80 Gy, and it is a promising material for application as a TLD dosimeter
APA, Harvard, Vancouver, ISO, and other styles
23

CARVALHO, JÚNIOR Alvaro Barbosa de. "Preparação e Caracterização de Quartzo Particulado e Discos Quartzo-Teflon para Dosimetria Termoluminescente das Radiações Ionizantes." Universidade Federal de Pernambuco, 2010. https://repositorio.ufpe.br/handle/123456789/4912.

Full text
Abstract:
Made available in DSpace on 2014-06-12T17:34:40Z (GMT). No. of bitstreams: 2 arquivo1984_1.pdf: 2960442 bytes, checksum: 79a756c68336d58b854cdb8661b3748d (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Recentemente, medidas da emissão TL realizadas em cristais de quartzo natural sensibilizado, mostraram resultados bastante favoráveis à sua aplicação como dosímetro TL. Também foi observado que a resposta TL do quartzo depende da concentração de impurezas e da procedência dos cristais. Estudos mostram que a utilização de materiais particulados contribui para uma diminuição da dispersão na resposta TL, o que permitiria a utilização de cristais de quartzo com distribuição heterogênea de impurezas. Assim, o objetivo deste trabalho foi desenvolver um procedimento para produção de discos de quartzo policristalinos e analisar a resposta TL em função do tamanho de partícula visando aplicações dosimétricas. Para tal, fragmentos de um bloco de quartzo natural procedente do município de Solonópole (Estado do Ceará, Brasil) foram cominuídos e classificados em dez faixas granulométricas, entre 38 e 4760 m. Parte do material particulado de cada faixa foi exposto a uma dose de 25 kGy utilizando uma fonte de 60Co e então submetido a três tratamentos térmicos consecutivos a 400 oC durante 1 hora. Após a sensibilização, foi constatado que a intensidade TL cresce com o aumento do diâmetro médio das partículas (Dm) de 18 para 304 μm. Entretanto, uma queda acentuada na intensidade TL foi observada para partículas com Dm > 304 μm. Este comportamento foi explicado pela baixa intensidade do sinal RPE associado aos centros E 1 perturbados pelo germânio substitucional. Nesta etapa, concluiu-se que partículas de quartzo sensibilizado com Dm entre 138 e 304 μm são recomendadas para utilização na dosimetria TL, e por esta razão, foram as escolhidas para a obtenção de discos policristalinos. Para produzir discos coesos de 6 mm de diâmetro, aglomerantes de natureza mineral e orgânica foram testados. Depois de definida a combinação adequada granulometria-aglomerante, discos quartzo-Teflon na proporção 1:1 foram produzidos por compactação em uma matriz metálica e posterior tratamento térmico a 400 oC durante 6 horas. A integridade dos discos produzidos foi caracterizada por meio de ensaios vibratórios e medidas de perda de massa, perfilometria de contato e microscopia eletrônica de varredura. Por sua vez, as propriedades dosimétricas foram caracterizadas pela análise da reprodutibilidade, estabilidade e sensibilidade do pico TL a 310 oC; da resposta TL vs. dose entre 0,5 e 200 mGy e da dependência energética para raios X e raios . Constatou-se que os discos quartzo-Teflon apresentaram reprodutibilidade melhor que 10%, maior sensibilidade que dosímetros LiF:Mg,Ti, estabilidade do sinal TL equivalente ao BeO e CaSO4;Dy e menor dependência energética que dosímetros CaSO4:Dy e CaF2:Dy. Portanto, a sensibilidade e linearidade da resposta TL do quartzo sensibilizado, associada à simplicidade do método de preparação proposto e a quantidade de ocorrências deste recurso mineral no Brasil, corroboram a viabilidade de utilização de discos quartzo-Teflon e também do quartzo particulado com Dm entre 138 e 304 μm para dosimetria TL das radiações ionizantes
APA, Harvard, Vancouver, ISO, and other styles
24

BEZERRA, Jairo Dias. "Dosimetria termoluminescente na avaliação da dose “indoor” das residências do Município de São José de Espinharas-PB." Universidade Federal de Pernambuco, 2015. https://repositorio.ufpe.br/handle/123456789/16245.

Full text
Abstract:
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-03-31T17:11:31Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Tese de Jairo Dias.pdf: 2064500 bytes, checksum: 77ff167e06534ac84843f461013c18c4 (MD5)
Made available in DSpace on 2016-03-31T17:11:31Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Tese de Jairo Dias.pdf: 2064500 bytes, checksum: 77ff167e06534ac84843f461013c18c4 (MD5) Previous issue date: 2015-08-07
CAPES
Estudos radioecológicos com dosimetria ambiental vêm sendo realizados mundialmente, principalmente para avaliar os níveis de radiação natural oriundos dos radionuclídeos primordiais presentes na crosta terrestre, tais como o 40K e os radionuclídeos das séries do 238U e do 232Th. Estes radionuclídeos são os que mais contribuem para a exposição gama externa em ambientes fechados, principalmente quando localizados em áreas que apresentam níveis diferenciados de radiação natural. Neste contexto, o presente trabalho teve como objetivo, determinar as taxas de doses efetivas externas dentro das residências, dose “indoor”, localizadas próximas à jazida de urânio do município de São José de Espinharas no estado da Paraíba, que contêm altos níveis de radionuclídeos terrestres, os quais constituem os Materiais Radioativos de Ocorrências Naturais (NORM). Para caracterizar o estudo radiométrico, foram instalados 178 conjuntos de dosímetros termoluminscentes, com três TLDs do tipo LiF:Mg, Ti (Fluoreto de Lítio dopado com Magnésio e Titânio) nos quartos das residências, sendo substituídos a cada 90 dias. Toda pesquisa foi realizada no período de dezembro de 2012 a novembro de 2014. As taxas de doses efetivas ambientais calculadas para São José de Espinharas variaram de 0,71 a 2,07 mSv.a-1, com média de 0,90 mSv.a-1. Municípios adjacentes à área de estudo também foram monitorados no referido estudo, destacando-se: São Mamede, São José do Sabugi, Patos e Santa Luzia com valores intervalares e médias de 0,77 a 1,41 mSv.a-1 (0,94 mSv.a-1); 0,90 a 1,67 mSv.a-1 (1,13 mSv.a-1); 0,77 a 0,93 mSv.a-1 (0,87 mSv.a-1) e 1,10 a 1,27 mSv.a-1 (1,18 mSv.a-1), respectivamente. A média geral do referido estudo ficou em torno de 0,99  0,10 mSv.a-1, correspondendo a um valor médio que é 2,5 vezes superior ao estimado para ambientes fechados conforme o Comitê Científico das Nações Unidas para os Efeitos das Radiações Atômicas (UNSCEAR) que é 0,41 mSv.a-1. Estes valores conferem aos municípios, influências exclusivas de materiais radioativos de ocorrências naturais devido à formação geológica da região, quando levado em consideração os níveis desses radionuclídeos. Observa-se que os resultados obtidos nesta monitoração radioecológica, não permite propor nenhuma condição de contaminação "indoor" sem antes monitorar a água, os alimentos, os materiais de construção, como também os habitantes para se predizer qualquer condição de risco real que esteja associada a população desses municípios.
Radioecological studies of environmental dosimetry have been conducted worldwide, mainly to assess the natural levels of radiation coming from the primordial radionuclides present in the earth's crust, such as 40K and radionuclides from 238U and 232Th series. These radionuclides are the main contributors to external gamma exposure indoors, especially when they are located in areas with different levels of radiation. In this context, this study aimed to determine the external effective dose rates inside houses (indoor dose), located near the uranium mine in the city of São José de Espinharas in the state of Paraiba, Northeast region, Brazil, that contain high levels of terrestrial radionuclides, which are the Naturally. Occurring Radioactive Material (NORM). To characterize the radiometric study, were installed 178 sets of thermoluminescent dosimeters, with three TLDs type LiF: Mg, Ti (lithium fluoride doped with Magnesium and Titanium) each, in the rooms of the residences, these being replaced on average, every 90 days, from December 2012 to November 2014. Environmental effective doses rates calculated for São José de Espinharas varied from 0.71 to 2.07 mSv.y-1 with an average of 0.90 mSv.y-1. Municipalities adjacent to the study area were also monitored in the study, highlighting: São Mamede, São José do Sabugi, Patos and Santa Luzia with interval values and averages of 0.77 to 1.41 mSv.y-1 (0, 94 mSv.y-1); 0.90 to 1.67 mSv.y-1 (1.13 mSv.y-1); 0.77 to 0.93 mSv.y-1 (0.87 mSv.y-1) and 1.10 to 1.27 mSv.y-1 (1.18 mSv.y-1), respectively. The overall average of the study was around 0.99 ± 0.10 mSv.y-1, corresponding to an average of 2.5 times higher than the estimated for indoors according to the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), which is 0.41 mSv.y-1, giving the municipalities, exclusive influences of radioactive materials of natural occurrences, due to the geological formation of the region, when taken into consideration the levels of these radionuclides. It is observed that the results of this radioecological monitoring, does not allow to propose any "indoor" contamination condition without first monitor water, food, building materials, as well as the residents to predict any real risk factor for the population of these municipalities.
APA, Harvard, Vancouver, ISO, and other styles
25

CAMPOS, VICENTE de P. de. "Desenvolvimento e avaliação de um novo porta detector/filtro para monitoramento termoluminescente com CaSOsub(4):Dy/PTFE." reponame:Repositório Institucional do IPEN, 2005. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11370.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:51:12Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T13:57:30Z (GMT). No. of bitstreams: 1 11253.pdf: 7162286 bytes, checksum: 8c317086ceb03e1882b7946a3ddefe94 (MD5)
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
26

Bitencourt, José Francisco Sousa. "Confecção e caracterização de dosímetro luminescente de óxido de alumínio dopado com magnésio." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/3/3140/tde-30092008-150315/.

Full text
Abstract:
O objetivo desse trabalho é confeccionar e caracterizar dosímetros luminescentes de óxido de alumínio, dopados com o elemento químico magnésio, para aplicação em dosimetria das radiações ionizantes. O óxido de alumínio é obtido pelo método do precursor polimérico; através da obtenção de resina polimérica que resulta em material cerâmico em pó após tratamentos térmicos em temperaturas específicas. As análises dosimétricas são realizadas durante ciclos de aquecimento de amostras que já tenham absorvido certa quantidade de radiação ionizante, ou dose radioativa, é a chamada Termoluminescência. Neste trabalho as fontes radioativas são emissoras de radiação- ou raios-X, que são mais presentes nos campos da radioterapia, radiodiagnóstico, geração de energia elétrica e estudos científicos. Devido às propriedades físicas do cristal, ocorre emissão de luz quando elétrons e buracos recebem energia térmica, permitindo a sua liberação de estados quânticos meta-estáveis e a recombinação com cargas opostas, liberando fótons no espectro UV/visível. A análise química por ICP AES indica as concentrações de 0,47; 0,88; 1,33; 2,61 e 3,36 mol% de Mg2+ para as cinco amostras preparadas com diferentes massas do reagente MgCO3; estes valores indicam que o procedimento para obtenção das amostras foi realizado com uniformidade adequada e, portanto, os resultados alcançados são proporcionais às concentrações de Mg2+. Inicialmente, analisando os resultados da difração de Raios-X, percebe-se que a menor temperatura utilizada para a calcinação do material cerâmico não foi suficiente para que se obtivesse a fase estrutural desejada (fase alfa), uma vez que a estrutura gama não exibiu propriedades dosimétricas para doses baixas. Este fato implicou em tratamentos térmicos adicionais em temperatura superior (1100°C). Os difratogramas obtidos comprovam a viabilidade do processo e metodologia, com amostras altamente cristalinas e ausência de fases desconhecidas que poderiam ocorrer caso houvesse contaminação. As medidas de TL acusaram uma forte emissão luminescente na região do espectro visível e UV, com picos de emissão em 125, 200, 280, 350 e 430°C, aproximadamente. Os últimos não puderam ser estudados para doses baixas, pois suas intensidades são sobrepostas pela incandescência do porta amostras. Entretanto, o pico de emissão em 200°C mostrou comportamento satisfatório e, portanto, empregado para estudos mais aprofundados. Os picos de alta temperatura (280, 360 e 430ºC) exibiram ótima resposta luminescente para altas doses absorvidas (acima de 100 Gy), sem que seu ponto de saturação fosse alcançado para doses de até 1 kGy. Variando sensivelmente a energia do feixe de irradiação foi possível determinar que a luminescência do material apresenta baixa dependência energética para energias abaixo de 40 keV, o que está de acordo com a teoria de interação energia/matéria. Acima desta energia, há diminuição do fenômeno fotoelétrico em detrimento do espalhamento Compton. As imagens obtidas por Microscopia Eletrônica de Transmissão detectaram, nas amostras dopadas, a presença de estruturas superficiais compostas por espinélio (MgAl2O4) sobre aglomerados de Al2O3. Este resultado faz crer que a ocorrência desta camada superficial aumenta significativamente a concentração de centros de recombinação e, conseqüentemente, a intensidade de emissão também é aumentada.
The aim of the present work is to obtain and characterize luminescent dosimeters made of magnesium doped aluminium oxide, for ionizing radiation dosimetry purposes. The material is produced by Pechini Method (US Patent 3.330.697, 1967), starting from a polymer that generates powder ceramic, after firing at predetermined temperatures. Dosimetric measurements were taken during heating cycles (Thermoluminescence) with gamma and X-rays irradiated samples. Due to physical properties of the crystal, light is emitted during heating, because of free carriers being released from trap centers and recombining with opposite sigh charges. Chemical analysis indicated the Mg2+ concentrations 0.47, 0.88, 1.32, 2.61 and 3.36 mol%; reactants masses and process parameters were adequate to obtain uniformity. From X-Ray Diffraction, samples calcinated at lower temperatures did not reach the properly structural phase. The gamma phase did not show dosimetric properties for the preferred spectra (UV/visible region). Calcinations at higher temperatures were necessary to obtain alpha phase, which exhibited TL emission. For doped sample, diffractograms indicated the occurrence of highly crystalline sample. TL glow curves showed high visible and UV emission, with peaks at 125, 200, 280, 365 and above 450°C. The lowest peak was faded within 24 hours after irradiation and those above 280°C could not be exactly determined due to peak overlapping. Nevertheless, the emission peak at 200°C showed itself a great achievement for the present work, because of its energy depth and dose response. For higher absorbed doses (above 100 Gy), the emission generated by deeper traps could be studied with more details: acceptable TL response and exponential growth were exhibited. The peak at 280 was not reported. Low energy dependence luminescence in observed for doses as high as 40 keV. This limitation is due to decreasing of photoelectric phenomena, which is responsible for charges trapping. Images obtained using Transmission Electron Microscopy detected surface layer in doped samples; such layer is composed by spinel (MgAl2O4). The presence of spinel layer increases recombination centers concentration, once luminescence enhancement was perceived for doped samples.
APA, Harvard, Vancouver, ISO, and other styles
27

Salmazo, Giovana Oliveira [UNESP]. "Caracterização das propriedades termoluminescentes de sedimentos da formação geológica Rio Claro." Universidade Estadual Paulista (UNESP), 2009. http://hdl.handle.net/11449/91988.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:25:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-10-21Bitstream added on 2014-06-13T20:53:36Z : No. of bitstreams: 1 salmazo_go_me_ilha.pdf: 1435780 bytes, checksum: 267d629a52fdf58b7156f4c83fc33587 (MD5)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
A formação geológica Rio Claro constitui um dos mais importantes registros sedimentares cenozóicos da Depressão Periférica Paulista. Apesar de essa formação geológica ser muito estudada, sua idade ainda encontra-se indeterminada. De modo a contribuir aos conhecimentos sobre a formação geológica Rio Claro, o trabalho objetivou um estudo geocronológico de seus sedimentos. Para isso, foram estudas cinco amostras sedimentares coletadas de pontos arbitrários da formação geológica, as quais foram denominadas de DSRC- 09, DSRC-10, DSRC-21, DSRC-22 e DSRC-23, e caracterizadas pela técnica da termoluminescência (TL). Grãos de quartzo de diâmetros entre 75 a 180 μm foram utilizados na caracterização. As amostras apresentaram sinal de termoluminescência natural entre 200 e 450 °C. Com exceção da amostra DSRC 22, todas as amostras apresentaram região de Plateau, que indica a região da curva de emissão que se manteve estável durante o período geológico a temperatura ambiente. A região de Plateau de DSRC-09, DSRC-10, DSRC 21 e DSRC-23 compreendeu o intervalo de temperatura de 320 a 380 °C. Pelo método Tm-Tstop se observou a presença de três picos constituindo a curva de emissão termoluminescente nessa região de temperatura. O nível residual da TL foi obtido após 80 horas de exposição dos grãos de quartzo à luz solar. Os sedimentos apresentaram não estar saturados, pois a intensidade do sinal TL aumentou em função de dose adicional artificial. Para a avaliação da idade dos sedimentos, o pico de 325 °C foi isolado e a energia de ativação foi calculada pelo método de crescimento inicial. As idades de deposição obtidas para as amostras DSRC-09, DSRC-10 e DSRC-21 foram respectivamente de 188.000 anos, 210.000 anos e 166.000 anos.
The geological formation Rio Claro constitutes one the most important sedimentary records of São Paulo Peripheral Depression. Although this geological formation is too much studied, its age yet is not determinate. To contribute to knowledge about Rio Claro geological formation, the work aimed a geocronological study of its sediments. For this, five sedimentary samples collected from arbitrary points were studied, which were called DSRC-09, DSRC-10, DSRC- 21, DSRC-22 and DSCR 23, and characterized by thermoluminescence technique. Grains of quartz with diameter between 75 and 180 μm were utilized to characterize it. The samples showed natural thermoluminescence signal between 200 and 450 °C. Except for the sample DSRC 22, all samples showed Plateau region, indicating that the region of glow curve remained stable during the geological time at environment temperature. Plateau region of DSRC-09, DSCR-10, DSRC-21 and DSRC-23 was defined by temperature range of 320 °C to 380°C. The method Tm-Tstop showed that the glow curves are composed by tree peaks in this temperature range. The residual TL was obtained after 80 hours of sunlight exposure. The sediments had not been saturated, because the TL signal intensity increased according to the artificial additional dose. For evaluation of the age sediments, the 325 °C peak was isolated and the activation energy was calculated by the method initial rise. The deposition ages for the samples DSRC-09, DSRC-10 and DSRC-21were respectively 188.000, 210.000 and 166.000 years.
APA, Harvard, Vancouver, ISO, and other styles
28

NÓBREGA, Boisguillebert Phillip Andrade Gorgônio da. "Estudo por espectroscopia RPE do efeito das altas doses de radiação gama no sinal termoluminescente do LiF:Mg,Cu,P." Universidade Federal de Pernambuco, 2017. https://repositorio.ufpe.br/handle/123456789/26577.

Full text
Abstract:
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-30T20:11:44Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Boisguillebert Phillip da Nóbrega.pdf: 6004845 bytes, checksum: 230fc0f3838645faa067b24a5b5f8601 (MD5)
Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-14T23:08:35Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Boisguillebert Phillip da Nóbrega.pdf: 6004845 bytes, checksum: 230fc0f3838645faa067b24a5b5f8601 (MD5)
Made available in DSpace on 2018-09-14T23:08:35Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Boisguillebert Phillip da Nóbrega.pdf: 6004845 bytes, checksum: 230fc0f3838645faa067b24a5b5f8601 (MD5) Previous issue date: 2017-06-27
O fluoreto de lítio dopado com Mg, Cu e P é muito utilizado na dosimetria termoluminescente (TL) das radiações ionizantes devido sua sensibilidade e linearidade da resposta TL em ampla faixa de doses, de μGy até kGy. Porém, tem-se verificado que sua curva TL se altera significativamente mediante irradiação com doses de raios gama >1 kGy. A principal alteração é a destruição do pico dosimétrico que ocorre a aproximadamente 220°C e o surgimento de um novo pico TL (denominado pico “B”) próximo a 450 °C. Embora as alterações na forma da curva TL estejam bem caracterizadas até 1 MGy, as armadilhas e o centro de recombinação relacionados ao pico B são desconhecidos. Além disso, o papel desempenhado por cada dopante no mecanismo TL ainda não é bem compreendido. Até então, a origem destas modificações foi investigada por medidas de emissão TL e espectroscopia de absorção óptica. A espectroscopia por ressonância paramagnética eletrônica (RPE) foi empregada apenas em amostras irradiadas com doses não suficientes para produzir o pico B. Neste contexto, o objetivo deste trabalho foi investigar as alterações causadas pelo efeito de altas doses de radiação gama na estrutura de centros paramagnéticos do LiF:Mg,Cu,P. O material empregado neste estudo é utilizado pelo Instituto de Física Nuclear da Polônia (IFJ, Cracóvia) para fabricar os dosímetros MCP-N. Alíquotas ~50 mg foram irradiadas com doses distintas (1, 100, 227 e 500 kGy); irradiador gammacell (⁶⁰Co; 2,7 kGy/h). Em seguida, foram realizados tratamentos térmicos entre 50 e 500 °C para acompanhar a estabilidade dos defeitos paramagnéticos e a eliminação progressiva do sinal TL. Os sinais de EPR foram medidos com um espectrômetro Bruker EMX operando na banda X na temperatura ambiente e do N₂líq. Curvas de absorção óptica e espectros de emissão TL foram obtidos. Os espectros RPE mostraram a presença de intensos sinais com simetria axial, cujos fatores g (g┴=2,1937; g║=2,0765) são compatíveis com os centros de Cu²⁺ na estrutura do LiF. Estes sinais foram observados em amostras naturais e suas intensidades diminuíram para doses >100 kGy nos espectros medidos à temperatura ambiente. Dois sinais menos intensos, com fatores g iguais a 2,008 e 1,989, provavelmente relacionados a centros de Mg²⁺, foram observados após irradiação com doses ≥100 kGy. As intensidades destes sinais diminuíram com o aumento do tratamento térmico da mesma forma como foi observado para o pico B. Como nenhum outro sinal RPE foi observado a baixa temperatura, concluiu-se que a coexistência de centros relacionados com os íons Cu²⁺ e Mg²⁺ é uma condição essencial para a ocorrência do pico B. O comprimento de onda da luz emitida (~380 nm) confirmou que o centro de recombinação tanto para o pico dosimétrico quanto para o pico B são os mesmo. Em contradição com os modelos TL de 1ª e 2ª ordem, constatou-se que o pico B deslocou-se para temperaturas mais elevadas com doses ≥100 kGy. Estes resultados sugerem que a origem do pico B pode ser explicada por um mecanismo de transições semi-localizadas em centros paramagnéticos relacionados aos íons Cu²⁺ e Mg²⁺.
Lithium fluoride doped with Mg, Cu and P is widely used in ionizing radiation thermoluminescent (TL) dosimetry due to its very high sensitivity and linear dose-response range from μGy to kGy. However, it has been found that its TL glow curve changes significantly by irradiation with gama radiation doses greater than 1 kGy. The major change is the destruction of the dosimetric peak occurring at approximately 220oC and the appearance of new TL peak (peak “B”) centered near 450oC. Although the changes in the pattern of the TL curves are well characterized up to 1 MGy, the origin of capture and recombination centers related to peak B is unknown. In addition, the role played by each dopant (Mg, Cu and P) in the TL mechanism is still not well understood. Recently, the origin of these modifications was investigated by TL emission and optical absorption spectroscopy. Until now, electron paramagnetic resonance (EPR) was employed only in samples irradiated with doses that were not enough to produce TL signal from the “B” peak. In this context, the objective of this work was to investigate the changes caused by high doses of gamma radiation on the structure of paramagnetic centers in LiF:Mg,Cu,P by EPR spectroscopy. The material used for this study is the same as used by the Institute of Nuclear Physics of Poland (IFJ, Krakow) to manufacture MCP-N detectors. Aliquots of 50 mg were irradiated with four doses (1, 100, 227 and 500 kGy); gammacell irradiator (60Co; 2.7 kGy/h). Thermal treatments were performed between 50 and 500 °C to monitor the stability of the paramagnetic defect and the progressive elimination of the TL signal. EPR signals were measured with a Bruker EMX spectrometer operating at X-band at room and N₂Liq temperatures. Optical absorption curves and TL emission spectra were also obtained. EPR spectra showed the presence of intense axial signals, whose factors originate e mainly from Cu-related centers with axially symmetric spectroscopic g-factors (g┴=2.1937; g║=2.0765). This signal was observed in as-received samples and its intensity decreased for doses >100 kGy. Two less intense signals with g-factors equal to 2.008 and 1.989 probably related to Mg-centers, were observed after irradiation with doses ≥100 kGy. Their intensities decreased with the increase of the preheat similarly as it was observed for the “B” peak. As no other EPR signal appeared in low temperature measuments, it was concluded that the coexistence of Cu²⁺ and Mg²⁺ related centers is an essential condition for the occurrence of the “B” peak. The wavelength of emitted light (~380 nm) has confirmed that recombination occurs along the same path for both the dosimetric peak and the “B” peak. In contradiction to TL models based on transitions of 1st and 2nd – order kinetics, it was found that the position of the “B” peak shifted towards higher temperatures with increasing dose. These results show that the origin of the “B” peak can be explained by a mechanism of semi-localized transitions in paramagnetic centers related to Cu²⁺ and Mg²⁺ ions, activated by high doses.
APA, Harvard, Vancouver, ISO, and other styles
29

GROSSI, FABIO H. "Caracterizacao e padronizacao de um sistema dosimetrico termoluminescente para radiacoes ultravioleta e laser utilizando o CaSO sub(4):Dy." reponame:Repositório Institucional do IPEN, 2002. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10987.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:46:32Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T13:56:07Z (GMT). No. of bitstreams: 1 08286.pdf: 4148498 bytes, checksum: f9d73111bc4c47c409ba95ffcaec8d14 (MD5)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
FAPESP:99/06632-0
APA, Harvard, Vancouver, ISO, and other styles
30

Bluszcz, Andrzej. "Datowanie luminescencyjne osadów czwartorzędowych - teoria, ograniczenia, problemy interpretacyjne." Praca habilitacyjna, Wydawnictwo Politechniki Śląskiej, 2000. https://delibra.bg.polsl.pl/dlibra/docmetadata?showContent=true&id=8076.

Full text
APA, Harvard, Vancouver, ISO, and other styles
31

Nunes, Maíra Goes. "Desenvolvimento do dosímetro termoluminescente de CaSO4:Ce, Eu para a monitoração individual e a dosimetria clínica de fótons e elétrons." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-09122013-140708/.

Full text
Abstract:
Detectores de sulfato de cálcio ativado com cério IV e európio III utilizando o politetrafluoretileno (PTFE, Teflon®) free-flow como aglutinante (CaSO4:Ce,Eu + Teflon®) foram produzidos pelo método da estampagem, desenvolvido em colaboração com a empresa Tecnoflon, a partir de cristais crescidos de acordo com uma nova variação da rota da evaporação lenta, também apresentada nesse trabalho, com as concentrações de 0,16 mol% de Eu3+ e de 0,15 mol% de Ce4+ na solução ácida precursora. O modelo de dosímetro pessoal desenvolvido consiste em cinco detectores aderidos a um cartão de 30 x 48 mm de cloreto de polivinila (PVC) 95% opaco à luz na faixa do espectro eletromagnético que vai do infravermelho ao ultravioleta, idêntico aos cartões de identificação utilizados no IPEN, por uma tira de 10 x 35 mm de filme adesivo do mesmo material e foi submetido aos testes de aceitação descritos no regulamento técnico IRD-RT Nº 002.01/95, Desempenho de Sistemas de Monitoração Individual Critérios e Condições, sendo aprovado em todos os testes. Para a dosimetria clínica, os próprios detectores foram considerados dosímetros termoluminescentes e submetidos aos testes de aceitação descritos no código de práticas da Agência Internacional de Energia Atômica Technical Report Series Nº 398, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water, [TRS-398, IAEA, 2000] adotado como protocolo de dosimetria pela maioria dos hospitais, sendo igualmente aprovados nesses testes. Os dosímetros desenvolvidos podem ser utilizados para a monitoração individual externa e para dosimetria clínica, apresentando a diferenciação do tipo e da energia da radiação com que foram irradiados e a redução de custos como as principais vantagens em relação aos dosímetros termoluminescentes atualmente utilizados nessas aplicações.
Calcium sulphate activated with cerium IV and europium III using the free-flow polytetrafluoroethylene (PTFE, Teflon®) as bonder were produced by the stamping method, developed by the collaboration of Tecnoflon industries, from crystals growth according to a new variation of the slow evaporation method, also described in this study, with Eu3+ and Ce4+ concentrations of respectively 0.15 mol% and 0.16 mol% in the precursory acid solution. The developed personal dosimeter consist of five detectors adhered to a 30 x 48 mm polyvinyl chloride (PVC) card 95% mat to light in the infrared to ultraviolet wavelengths, identical to the access cards used by IPEN staff, by a 10 x 35 mm adhesive strip of the same material and it passed the acceptance tests required by Brazilian national regulatory committee for appliance in individual monitoring of external exposure services. The own detector is considered a dosimeter as far as clinical dosimetry is concerned and it passed the acceptance tests suggested by the International Atomic Energy Agency in the Technical Report Series Nº 398, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water, [TRS-398, IAEA, 2000] adopted as the dosimetry protocol by most hospitals. Hence, the developed dosimeters can be applied in the individual monitoring for external exposure and in the clinical dosimetry, having the radiation type and energy differentiation and the cost reduction as the key advantages over the currently used thermoluminescent dosimeters in such applications.
APA, Harvard, Vancouver, ISO, and other styles
32

SOUZA, Leonardo Bruno Ferreira de. "Estudo da sensibilização da resposta termoluminescente do quartzo de Solonópole (CE) por tratamentos térmicos e altas doses de radiação gama." Universidade Federal de Pernambuco, 2008. https://repositorio.ufpe.br/handle/123456789/9790.

Full text
Abstract:
Made available in DSpace on 2014-06-12T23:16:10Z (GMT). No. of bitstreams: 2 arquivo8647_1.pdf: 8160673 bytes, checksum: 12d10551e46fdf8c96294a4c26e0dfdc (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008
Conselho Nacional de Desenvolvimento Científico e Tecnológico
A sensibilização da resposta termoluminescente (TL) do quartzo natural foi muito estudada visando a datação arqueológica e a dosimetria retrospectiva. Embora a curva de emissão TL do quartzo apresente vários picos, apenas a sensibilização do pico que ocorre a aproximadamente 100°C foi investigada em profundidade. Trabalhos recentes mostraram que a sensibilização TL do pico a 300°C ocorre apenas quando altas doses de radiação gama são administradas em cristais naturais cujas concentrações relativas de impurezas Li/Al e Li/OH são elevadas. Observou-se também que a sensibilização depende da intensidade de dose utilizada. Entretanto, poucas medidas foram realizadas no intervalo que antecede 50 kGy. Além disso, não foi esclarecido como os tratamentos térmicos podem influenciar a sensibilidade TL do quartzo. Portanto, o objetivo deste trabalho é estudar a sensibilização da resposta TL do quartzo natural por tratamentos térmicos e altas doses de radiação gama. Para isto, foram extraídos cinqüenta e cinco discos com 6x1 mm2 de um bloco procedente de Solonópole (CE). Os discos foram separados em seis lotes de acordo com a proximidade da resposta TL entre 160°C e 320°C. Um dos lotes foi submetido à doses de radiação (60Co) a partir de 2 kGy, chegando a uma dose acumulada de 50 kGy. Outros três lotes foram inicialmente tratados a 500°C, 800°C e 1000°C e posteriormente irradiados com duas doses de 25 kGy. As curvas de emissão e as curvas de calibração, para dose-teste de 0,1 a 30 mGy, foram obtidas após cada procedimento de sensibilização. Amostras retangulares de 10x10 mm2 foram utilizadas para caracterizar os defeitos pontuais relacionados às impurezas de Al e OH em função dos procedimentos de sensibilização. O centro [AlO4]° foi caracterizado por espectroscopia no UV-VIS e os centros [AlO4/H+]°, [H4O4]° e Li-OH, por espectroscopia infravermelho. Como resultado, foi observado que o material em sua condição natural apresenta um pico a 325°C, mas este possui baixa intensidade TL. Os tratamentos térmicos não sensibilizam o pico a 300°C, o que ocorre somente após a administração de doses acima de 2 kGy. Utilizando apenas altas doses, observou-se que a sensibilidade TL aumenta até 15 kGy. Acima desta dose, a sensibilidade TL praticamente não se modifica. Observou-se que a concentração do centro [AlO4]°, que atua como centro de recombinação, aumenta em função da dose acumulada, mesmo para doses acima de 15 kGy. Portanto, concluiu-se que a estabilização da sensibilidade TL está relacionada à quantidade de armadilhas de elétrons. Por outro lado, observou-se que o íon Li+ é dissociado do centro Li-OH por irradiação e tratamentos térmicos. Verificou-se ainda que para doses acumuladas acima de 15 kGy, acompanhadas de três tratamentos a 400°C, o centro Li-OH não se restitui por completo. Desta forma, foi sugerido que os íons Li+ formam armadilhas competidoras. O aumento da concentração de armadilhas competidoras pode explicar a estabilização da sensibilidade TL acima de 15 kGy. Verificou-se que o procedimento de sensibilização mais adequado para este cristal envolve um tratamento a 1000°C, dose de 25 kGy e três tratamentos térmicos a 400°C
APA, Harvard, Vancouver, ISO, and other styles
33

Ferreira, Sandra Regina. "Análise pedoestratigráfica das formações Rio Claro e Piraçununga, no Centro-Leste do Estado de São Paulo /." Rio Claro : [s.n.], 2005. http://hdl.handle.net/11449/102868.

Full text
Abstract:
Resumo: Neste trabalho são analisados perfis de solo das formações Rio Claro e Piraçununga, na região dos municípios homônimos, com relação às características morfológicas, granulométricas e mineralógicas, com vistas ao entendimento de sua evolução. A partir destas informações e aplicando a técnica de pedoestratigrafia, foi possível estabelecer a ocorrência de uma Unidade Pedoestratigráfica, soterrada por arenitos fluviais das formações estudadas. Os principais minerais encontrados nos perfis de solo são quartzo e caulinita, secundariamente gibsita, clorita, óxidos e hidróxidos de ferro e traços de feldspatos. Ocorrem, ainda, argilominerais interestratificados: nos solos da Formação Rio Claro, encontrou-se caulinita/esmectita e montmorilonita/sepiolita; nos solos da Formação Piraçununga, montmorilonita/vermiculita e caulinita/haloisita. A presença de argilominerais estáveis e instáveis conjuntamente, bem como os índices ki e kr, evidenciam que estes solos ainda não atingiram o grau máximo de pedogênese, constituindo perfis relativamente jovens como os pertencentes às classes dos Cambissolos, Nitossolos e Neossolos; que recobrem antigos solos da Unidade Pedoestratigráfica identificada na base dos perfis. Sedimentos das formações Rio Claro e Piraçununga, amostrados nos perfis estudados, foram datados por termoluminescência, apresentando idades do Pleistoceno e do limite Pleistoceno/Holoceno. A mais antiga foi determinada em perfil da Formação Rio Claro, datando de 745000 AP, e a mais recente, em perfil da Formação Piraçununga, com 15000 AP, esta última em depósitos coluvionares sobrepostos. Os materiais que constituem os perfis modais foram datados entre 400000 AP e 145000 AP, em ambas unidades.
Abstract: Soil profiles of Rio Claro and Piraçununga formations are analyzed, in the vicinity of the cities of the same names, with respect to their morphologic, textural and mineralogical characteristics, looking for their pedological evolution. By applying the concepts of Pedostratigraphy, it was stablished one Pedostratigraphic Unit, buried by fluvial sandstones of both units. The main minerals found in soil profiles are quartz and kaolinite; secondary gibbsite, chlorite, iron oxides and hydroxides; and trace feldspar. There were also found interstratified clay minerals: kaolinite/smectite and montmorillonite/sepiolite in soil profiles of Rio Claro Formation; montmorillonite/vermiculite and kaolinite/halloysite in soil profiles of Piraçununga Formation. The occurrence of stable and unstable clay minerals together and the values of ki and kr, indicate that the studied soils have not achieved the maximum grade of pedogenetic development and may be compared to young soils like Inceptsols, Alfisols and Entisols, that overly an old soil of the Pedostratigraphic Unit at the base of the soil profiles. The sandstones of Rio Claro and Piraçununga formations were dated by the method of thermoluminescence, revealing ages of the Pleistocene and of the Pleistocene/Holocene boundary. The oldest age was determined for Rio Claro Formation (745000 AP) and the youngest for the Piraçununga Formation (15000 AP). The sediments of modal soil profiles of both formations range from 400000 AP to 145000 AP ages.
Orientador: Maria Rita Caetano Chang
Coorientador: Chang Hung Kiang
Banca: Paulo Milton Barbosa Landim
Banca: Jairo Roberto Jiménez Rueda
Banca: Wanderley Antonio Tremocoldi
Banca: Reinaldo Lorandi
Doutor
APA, Harvard, Vancouver, ISO, and other styles
34

Ribeiro, Silvia Lucia Vieira. "Determinação atraves do metodo da dosimetria termoluminescente, das doses de radiação incidentes em orgãos criticos, durante a obtenção de radiografias extra-bucais." [s.n.], 1989. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288490.

Full text
Abstract:
Orientador: Ana Lucia Ribeiro de Almeida Vergueiro, Ruth Maria Bannwart Cardoso dos Santos
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-14T04:04:48Z (GMT). No. of bitstreams: 1 Ribeiro_SilviaLuciaVieira_M.pdf: 1203454 bytes, checksum: 4d749636f0a22fe80b9607bb6d2f5ed9 (MD5) Previous issue date: 1989
Resumo: O presente estudo teve o propósito de determinar o valor de doses de radiação incidentes em determinadas regiões consideradas críticas, de pacientes submetidos a exames radiográficos extra-bucais de interesse na Odontologia. Para isso, foi usada a dosimetria termoluminescente (LiF-700). Os resultados evidenciaram que os níveis de radiação, decorrentes de radiografias extra-bucais realizadas em indivíduos com diversos tipos morfológicos de face, mostram diferenças entre si, sugerindo que existe significância entre os níveis de radiação em função do tipo morfológico de face. Com relação às técnicas radiogrificas para A. T.M., constatamos que a técnica transcranial de Updegrave provocou um índice de radiação maior nos órgãos críticos, quando comparada com a transfacial de McQueen. As técnicas póstero-anteriores apresentaram um nível próximo de incidência,em todas as regiões consideradas. Quanto às técnicas de Shuller e lateral para perfil, podemos dizer que apresentaram níveis de incidência semelhantes a dados existentes na literatura
Abstract: The aim of the work was to determine the value of radiation doses that falI in certain areas, considered critical, on patients submitted to extra-buccal radiographic examination. These doses and their value are of very much interest for Dentistry. For this, the termoluminescent dosimetry was used (LiF-700). The resul ts showed tkat the levels of radiation from extra-buccal radiography was variable, suggesting a relation with the facial characteristics of the patient. Concerning the radiographic technics, it verified that the transcranial technic of updegrave gave wa's larger index of radiation on the critical organs, when compared to the transfacial technic of McQueen. The postero-anterior technics showed a similar leveI of incidence in alI the considered areas. The results with the Shuller technics and lateral to Profile were according to the data found in the literature
Mestrado
Radiologia
Mestre em Odontologia
APA, Harvard, Vancouver, ISO, and other styles
35

Federico, Claudio Antonio. "Medida do Perfil de Dose no Alumínio Irradiado com Raios Gama de Captura de Nêutrons Térmicos Utilizando o Dosímetro Termoluminescente CaSO4:Dy." Universidade de São Paulo, 2002. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-31102011-090842/.

Full text
Abstract:
Radiação gama com energias maiores que 1,25 MeV são usualmente encontradas em ambientes de reatores, aceleradores de partículas e campos de radiação de origem cósmica. Nestas energias, a resposta de um dosímetro varia fortemente com a espessura de material absorvedor, até atingir um valor máximo conhecido como espessura de equibl^rio de partículas carregadas. O objetivo principal do presente trabalho foi a determinação experimental do perfil de dose absorvida por uma amostra de alumínio, para várias energias de feixes de raios gama, de forma a obter uma relação entre a energia média do campo de radiação gama e a espessura de equilíbrio de partículas carregadas para o alumínio. Os dosímetros foram irradiados com radiação gama produzida pela captura de neutrons térmicos em 23 materiais alvos no arranjo experimental montado no canal tangencial do reator do IPEN-CNEN/SP. Na determinação da camada de equilíbrio de partículas carregadas, foi ajustada aos dados experimentais uma função semi-empirica que permitiu obter a espessura de ETPC (Equilíbrio Transitório de Partículas Carregadas) para cada espectro de radiação gama utilizado neste trabalho, com energia média variando no intervalo de 3,26 a 7,85 MeV. Os resultados experimentais do presente trabalho permitiram obter uma relação entre a energia média do campo de radiação gama e a espessura de ETPC, que apresenta uma excelente concordância com o alcance corrigido dos elétrons gerados naquela energia.
Gamma radiation with energies greater than 1.25 MeV are usually produced in reactor environments, particle accelerators and in cosmic radiation fields. For these energies, the response of a dosimeter heavily vary with the absorber material thickness, up to attain a maximum value named as charged particle equilibrium thickness. The main gol of this paper was the experimental determination of the absorbed dose profile in an aluminum sample for several energies of gamma ray beam, in order to obtain a relationship between the average energy of the gamma radiation field and the charged particle equilibrium thickness. The dosimeters were irradiated with gamma radiation produced by thermal neutron capture in 23 target materials in the experimental arrangement mounted at the tangential beam hole of the BPEN-CNEN/SP reactor. For the determination of the charged particle equilibrium thickness, it was fitted to the experimental data a semi-empirical fimction which allowed to obtain the thickness of CTPE ( Charged Particle Transient Equilibrium ) for each gamma radiation spectrum used in this work, with average energy varying in the interval from 3.26 to 7.85 MeV. The experimental results of the present paper allowed to obtain a relationship between average energy of the radiation field and the CTPE thickness, which presents an excellent agreement with the corrected range for electrons produced in that energy.
APA, Harvard, Vancouver, ISO, and other styles
36

PINTO, Beatriz Villa-­‐Chan Cantalupo. "Estimativa da dose e risco em pacientes Pediátricos devido a exames radiográficos dos Seios da face." Universidade Federal de Pernambuco, 2015. https://repositorio.ufpe.br/handle/123456789/16747.

Full text
Abstract:
Submitted by Haroudo Xavier Filho (haroudo.xavierfo@ufpe.br) on 2016-04-20T17:12:27Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO FINAL PARA IMPRESSÃO CAPA DURA.compressed.pdf: 5438350 bytes, checksum: 6a32a2d9accc05fb896d407a8a699c4b (MD5)
Made available in DSpace on 2016-04-20T17:12:27Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO FINAL PARA IMPRESSÃO CAPA DURA.compressed.pdf: 5438350 bytes, checksum: 6a32a2d9accc05fb896d407a8a699c4b (MD5) Previous issue date: 2015-05-31
CAPES
FACEPE
No presente trabalho, foi realizado um levantamento das doses recebidas por pacientes pediátricos, em exames radiográficos convencionais dos seios da face, realizados no Recife, PE. Para a realização do estudo, foram selecionados dois hospitais que atendem ao Sistema Único de Saúde, com alta demanda de exames pediátricos. Os dados dos pacientes e os parâmetros de irradiação utilizados em 159 exames radiográficos dos seios da face de crianças, com idades entre 0 e 15 anos, foram coletados, sendo 103 radiografias realizadas na projeção lateral (radiografia cavum) e 56 radiografias realizadas nas projeções pósteroanteriores em fronto-naso (FN) e mento-naso (MN) (radiografias Caldwell e Waters, respectivamente). Inicialmente, foram efetuadas as avaliações de desempenho dos dois equipamentos de raios X pertencentes aos hospitais. A partir dos valores dos rendimentos dos tubos de raios X e dos parâmetros de irradiação empregados nos exames, foram estimados os valores de kerma no ar na superfície de entrada (Ka,e) e produto kerma no ar-área (PK,A). Os valores de kerma no ar nas regiões dos olhos e da tireoide foram estimados utilizando dosímetros termoluminescentes (TLD-100). As doses absorvidas médias nos órgãos e a dose efetiva foram estimadas com o software PCXMC® a partir dos dados antropométricos, parâmetros de irradiação e do kerma no ar incidente (Ka,i), obtido com o rendimento. Os resultados mostraram que os valores de Ka,e variaram entre 0,065 mGy e 1,113 mGy, para radiografias cavum, entre 0,13 mGy e 7,99 mGy, para radiografias na incidência Caldwell e entre 0,13 mGy e 10,12 mGy, para radiografias na incidência Waters. Os valores do kerma no ar na região dos olhos variaram entre 0,001 mGy e 0,968 mGy, nas radiografias cavum, e 0,011 mGy e 0,427 mGy, nas incidências Caldwelll e Waters (conjuntamente). Na região da tireoide, os valores de kerma no ar variaram entre 5 μGy e 932 μGy, para as radiografias cavum, e 2 μGy e 972 μGy, para as incidências Caldwell e Waters. 90% dos valores de Ka,e estimados para os exames realizados no Hospital B encontram-se dentro do recomendado pela comunidade britânica, enquanto todos no Hospital A encontram-se acima. O fato do Hospital B apresentar valores de Ka,e dentro do aconselhado não significa que seu serviço esteja otimizado, devido a grande quantidade de filmes rejeitados, cuja imagem apresentava-se clara e inapropriada para o diagnóstico, elevando a dose final recebida pelo paciente pela repetição do exame. Os altos valores de Ka,e devem-se, principalmente, à utilização indiscriminada da grade antiespalhamento, não recomendada para pacientes desta idade. Os valores de PK,A variaram entre 5,7 mGy.cm2 e 92,3 mGy.cm2 para as radiografias cavum, entre 24,4 mGy.cm2 e 340,3 mGy.cm2 para as radiografias Caldwell e, entre 34,0 mGy.cm2 e 378,3 mGy.cm2 para as radiografias Waters. A partir dos dados pode-se concluir que há necessidade de otimização dos procedimentos radiográficos.
In this study, a survey was conducted in order to assess doses received by pediatric patients ongoing conventional radiographs of the sinuses, performed in Recife, PE. For the study, two hospitals of SUS (Sistema Único de Saúde), with high demand for pediatric examinations, were selected. Patient data and irradiation parameters were collected for 159 radiographs of the children’s sinuses with ages between 0 and 15. Among those, 103 radiographs were taken on the lateral projection (cavum radiography) and 56 radiographs were taken in posteroanterior projections in fronto-naso (FN) and mento-naso (MN) (Caldwell and Waters radiographs, respectively). Initially, the performance of the two X-ray equipment was evaluated. Air kerma values at the entrance surface (Ka,e), and air kerma area product (PK,A) were estimated using X-ray tubes output and irradiation parameters used in the examinations. Air Kerma values on the eyes and thyroid were estimated using thermoluminescent dosimeters (TLD-100). The average absorbed organ doses and effective dose were estimated at the PCXMC® software using the anthropometric data, irradiation parameters and the incident air kerma (Ka,i) obtained with the x-ray tube output. The results showed that Ka,e values varied between 0.065 and 1.113 mGy for cavum radiographs; between 0.13 and 7.99 mGy for Caldwell’s view; and between 0.13 and 10.12mGy for Waters’ view. The air kerma values in at the eye region varied from 0.001 mGy to 0.968 mGy for cavum radiographs, and from 0.011 mGy to 0.427 mGy for Caldwell and Waters’ views (together). In the thyroid region air kerma values ranged from 5 μGy to 932 μGy for cavum view and from 2 μGy to 972 μGy for Caldwell and Waters’ views. Tests performed at Hospital B have shown that 90% of the Ka,e values estimated during exams are within the recommended values by British Commonwealth, while all the Ka,e values in the Hospital A were above it. However, even though Hospital B presented Ka,e values within recommended values, this service was not optimized, due to the large amount of rejected films, whose image were inappropriate for diagnosis resulting in increased dose by the patient re-examination. The high Ka,e values are due mainly to the indiscriminate use of anti-scatter grid, not recommended for patient ages assessed in this study. PK,A values varied between 5.7 and 92.3 mGy.cm2 for cavum radiographs, between 24.4 and 340.3 mGy.cm2 for Caldwell’s view and between 34.0 and 378.3 mGy.cm2 for Waters’ view. Thus, it was concluded that there is need for optimization of radiographic procedures.
APA, Harvard, Vancouver, ISO, and other styles
37

FEDERICO, CLAUDIO A. "Medida do perfil de dose no aluminio, irradiado com raios gama de captura de neutrons termicos, utilizando o dosimetro termoluminescente CaSO sub(4):Dy." reponame:Repositório Institucional do IPEN, 2002. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11024.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:47:05Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T14:10:11Z (GMT). No. of bitstreams: 0
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
38

Tomaz, Lucas Crusoé. "Estudo da deposição de dose para diferentes configurações de sementes oncoseed 6711." CNEN - Centro de Desenvolvimento da Tecnologia Nuclear, Belo Horizonte, 2013. http://www.bdtd.cdtn.br//tde_busca/arquivo.php?codArquivo=286.

Full text
Abstract:
Nenhuma
O câncer de próstata é o segundo mais ocorrente entre os homens. A braquiterapia com a utilização de sementes de iodo-125 se apresenta como uma das formas de tratamento. Na terapia do câncer de próstata são utilizadas de 80 a 120 sementes de iodo-125 que são implantadas no órgão seguindo um planejamento. Durante o posicionamento e com o passar do tempo, as sementes implantadas sofrem pequenos deslocamentos em relação à posição inicialmente planejada. Estes deslocamentos podem causar diferenças na deposição de dose no volume tumoral. Este trabalho fez um estudo de dosimetria de sementes de iodo-125 utilizadas em braquiterapia de baixa taxa de dose. Na primeira etapa do trabalho, foi realizado o levantamento dos parâmetros dosimétricos da semente seguindo as recomendações do protocolo TG-43 com o objetivo de validar a metodologia. Em seguida, foi realizado um estudo quantitativo da variação na distribuição de dose para três configurações de quatro sementes Oncoseed 6711, sendo duas delas com as quatro sementes em posições simétricas e uma com as sementes apresentando pequenos deslocamentos. Utilizou-se um objeto simulador de tecido mole e dosímetros TLD. Em seguida, um estudo qualitativo das isodoses geradas pelas configurações foi realizado utilizando-se filme radiocrômico, modelo Gafchromic. Este método foi utilizado a fim de complementar o estudo realizado com os cristais. Os parâmetros dosimétricos da semente levantados neste trabalho apresentaram excelente concordância com os valores consensuais do TG -43, validando assim, a metodologia empregada nesta pesquisa. Finalmente, os resultados obtidos com filmes radiocrômicos e dosímetros termoluminescentes mostraram que existe uma diferença significativa na distribuição de dose quando há modificação de posicionamento entre as sementes. A utilização destes dois métodos simultaneamente se mostrou eficiente uma vez que os cristais trazem uma visão pontual e o filme traz uma visão global da distribuição de dose.
Prostate cancer is the second most common cancer among men. Iodine-125 brachytherapy seeds are presented as a form of treatment. In prostate cancer therapy 80-120 iodine-125 seeds are implanted in the organ following a previous planning. During positioning and after it, the implanted seeds can undergo slight displacements relative to the original position. These deviations may cause changes in dose distribution in the tumor volume. This work has made a dosimetry study for iodine-125 seeds used in low dose rate brachytherapy. In the first stage, we performed a one seed dosimetric parameters study following the TG-43 protocol recommendations with the objective of validating our methodology. Then a quantitative study of the variation in dose distribution for three configurations of four seeds OncoSeed 6711 was conducted with two configurations using the seeds in symmetrical positions and the other presenting small displacements. A soft tissue phantom and TLD dosimeters were used. Then a qualitative study of isodose curves of the configurations was performed using radiochromic film, Gafchromic model. This method was used to complement the study of the crystals. The seeds dosimetric parameters obtained in this work showed excellent agreement with the TG-43 consensual values, thus validating the methodology used in this work. The results obtained with radiochromic film and thermoluminescent dosimeters have shown that there is a significant difference in dose distribution when there is a change in the positioning of the seeds. The use of these two methods simultaneously is efficient since the crystals bring a point view and the film has a global view of the dose distribution
APA, Harvard, Vancouver, ISO, and other styles
39

Ferreira, Sandra Regina [UNESP]. "Análise pedoestratigráfica das formações Rio Claro e Piraçununga, no Centro-Leste do Estado de São Paulo." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/102868.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:32:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-10-06Bitstream added on 2014-06-13T18:43:29Z : No. of bitstreams: 1 ferreira_sr_dr_rcla.pdf: 9229845 bytes, checksum: 94c7f5d9a6e17d171ba1642e654d089e (MD5)
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Neste trabalho são analisados perfis de solo das formações Rio Claro e Piraçununga, na região dos municípios homônimos, com relação às características morfológicas, granulométricas e mineralógicas, com vistas ao entendimento de sua evolução. A partir destas informações e aplicando a técnica de pedoestratigrafia, foi possível estabelecer a ocorrência de uma Unidade Pedoestratigráfica, soterrada por arenitos fluviais das formações estudadas. Os principais minerais encontrados nos perfis de solo são quartzo e caulinita, secundariamente gibsita, clorita, óxidos e hidróxidos de ferro e traços de feldspatos. Ocorrem, ainda, argilominerais interestratificados: nos solos da Formação Rio Claro, encontrou-se caulinita/esmectita e montmorilonita/sepiolita; nos solos da Formação Piraçununga, montmorilonita/vermiculita e caulinita/haloisita. A presença de argilominerais estáveis e instáveis conjuntamente, bem como os índices ki e kr, evidenciam que estes solos ainda não atingiram o grau máximo de pedogênese, constituindo perfis relativamente jovens como os pertencentes às classes dos Cambissolos, Nitossolos e Neossolos; que recobrem antigos solos da Unidade Pedoestratigráfica identificada na base dos perfis. Sedimentos das formações Rio Claro e Piraçununga, amostrados nos perfis estudados, foram datados por termoluminescência, apresentando idades do Pleistoceno e do limite Pleistoceno/Holoceno. A mais antiga foi determinada em perfil da Formação Rio Claro, datando de 745000 AP, e a mais recente, em perfil da Formação Piraçununga, com 15000 AP, esta última em depósitos coluvionares sobrepostos. Os materiais que constituem os perfis modais foram datados entre 400000 AP e 145000 AP, em ambas unidades.
Soil profiles of Rio Claro and Piraçununga formations are analyzed, in the vicinity of the cities of the same names, with respect to their morphologic, textural and mineralogical characteristics, looking for their pedological evolution. By applying the concepts of Pedostratigraphy, it was stablished one Pedostratigraphic Unit, buried by fluvial sandstones of both units. The main minerals found in soil profiles are quartz and kaolinite; secondary gibbsite, chlorite, iron oxides and hydroxides; and trace feldspar. There were also found interstratified clay minerals: kaolinite/smectite and montmorillonite/sepiolite in soil profiles of Rio Claro Formation; montmorillonite/vermiculite and kaolinite/halloysite in soil profiles of Piraçununga Formation. The occurrence of stable and unstable clay minerals together and the values of ki and kr, indicate that the studied soils have not achieved the maximum grade of pedogenetic development and may be compared to young soils like Inceptsols, Alfisols and Entisols, that overly an old soil of the Pedostratigraphic Unit at the base of the soil profiles. The sandstones of Rio Claro and Piraçununga formations were dated by the method of thermoluminescence, revealing ages of the Pleistocene and of the Pleistocene/Holocene boundary. The oldest age was determined for Rio Claro Formation (745000 AP) and the youngest for the Piraçununga Formation (15000 AP). The sediments of modal soil profiles of both formations range from 400000 AP to 145000 AP ages.
APA, Harvard, Vancouver, ISO, and other styles
40

Martins, Juliana Cristina. "Estimativa de dose nos pulmões para procedimentos de tomografia computadorizada." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/43/43134/tde-16052016-082136/.

Full text
Abstract:
Desde o seu desenvolvimento na década de 1970 a tomografia computadorizada (TC) passou por grandes mudanças tecnológicas, tornando-se uma importante ferramenta diagnóstica para a medicina. Consequentemente o papel da TC em diagnóstico por imagem expandiu-se rapidamente, principalmente devido a melhorias na qualidade da imagem e tempo de aquisição. A dose de radiação recebida por pacientes devido a tais procedimentos vem ganhando atenção, levando a comunidade científica e os fabricantes a trabalharem juntos em direção a determinação e otimização de doses. Nas últimas décadas muitas metodologias para dosimetria em pacientes têm sido propostas, baseadas especialmente em cálculos utilizando a técnica Monte Carlo ou medições experimentais com objetos simuladores e dosímetros. A possibilidade de medições in vivo também está sendo investigada. Atualmente as principais técnicas para a otimização da dose incluem redução e/ou modulação da corrente anódica. O presente trabalho propõe uma metodologia experimental para estimativa de doses absorvidas pelos pulmões devido a protocolos clínicos de TC, usando um objeto simulador antropomórfico adulto e dosímetros termoluminescentes de Fluoreto de Lítio (LiF). Sete protocolos clínicos diferentes foram selecionados, com base em sua relevância com respeito à otimização de dose e frequência na rotina clínica de dois hospitais de grande porte: Instituto de Radiologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (InRad) e Instituto do Câncer do Estado de São Paulo Octávio Frias de Oliveira (ICESP). Quatro protocolos de otimização de dose foram analisados: Auto mA, Auto + Smart mA, Baixa Dose (BD) e Ultra Baixa Dose (UBD). Os dois primeiros protocolos supracitados buscam redução de dose por meio de modulação da corrente anódica, enquanto os protocolos BD e UBD propõem a redução do valor da corrente anódica, mantendo-a constante. Os protocolos BD e UBD proporcionaram redução de dose de 72,7(8) % e 91(1) %, respectivamente; 16,8(1,3) % e 35,0(1,2) % de redução de dose foram obtidas com os protocolos Auto mA e Auto + Smart mA, respectivamente. As estimativas de dose para os protocolos analisados neste estudo são compatíveis com estudos similares publicados na literatura, demonstrando a eficiência da metodologia para o cálculo de doses absorvidas no pulmão. Sua aplicabilidade pode ser estendida a diferentes órgãos, diferentes protocolos de CT e diferentes tipos de objetos simuladores antropomórficos (pediátricos, por exemplo). Por fim, a comparação entre os valores de doses estimadas para os pulmões e valores de estimativas de doses dependentes do tamanho (Size Specific Dose Estimates SSDE) demonstrou dependência linear entre as duas grandezas. Resultados de estudos similares exibiram comportamentos similares para doses no reto, sugerindo que doses absorvidas pelos uma órgãos podem ser linearmente dependente dos valores de SSDE, com coeficientes lineares específicos para cada órgão. Uma investigação mais aprofundada sobre doses em órgãos é necessária para avaliar essa hipótese.
Since its development in 1970s the computer tomography (CT) technique have gone through major technological advances, becoming an important diagnostic tool in medicine. Consequently the role of CT in diagnostic imaging expanded rapidly, mainly due to improvements in image quality and speed of acquisition. The radiation dose imparted in patients undergoing CT scans has gained attention, leading the radiology community (radiologists, medical physicists and manufacturers) to work together towards dose estimation and optimization. New methodologies for patients dosimetry have been proposed in the past decades, based specially on Monte Carlo calculations or experimental measurements with phantoms and dosimeters. In vivo methodologies are also under investigation. Current dose optimization strategies include mainly tube current reduction and/or tube current modulation. The present work proposes a methodology to experimentally estimate lung absorbed doses due to clinical CT protocols using an adult anthropomorphic phantom and Lithium Fluorite (LiF) thermoluminescent dosimeters (TLD). Seven clinical protocols were selected for phantom irradiation, based on their relevance regarding dose optimization and frequency in two major hospitals routine: the Institute of Radiology from the Medical Faculty from the University of São Paulo (Instituto de Radiologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo InRad) and the Cancer Institute of the State of São Paulo Octávio Frias de Oliveira (Instituto do Câncer do Estado de São Paulo Octávio Frias de Oliveira ICESP). Fours thorax protocols for dose optimization were analyzed: Auto mA, Auto + Smart mA, Low Dose (LD) and Ultra Low Dose (ULD) thorax. The first two aforementioned protocols seek dose reduction by tube current modulation, while the last two propose a decrease on the constant tube current value. Values of 72.9(8) % and 91(1) % of lung dose reduction were achieved with LD and ULD protocols, respectively. Auto mA and Auto + Smart mA provided 16.8(1.3) % and 35.0(1.2) % of lung dose reduction, respectively. The results from all analyzed protocols are compatible with similar studies published in literature, demonstrating the efficiency of the methodology to lung absorbed dose estimation. Its applicability could be extended to different organs, different clinical CT protocols and pediatric phantoms. Moreover, comparison of lung absorbed doses and Size Specific Dose Estimates (SSDE) for the studied protocols exhibited a tendency of linear dependency. Results from similar studies demonstrate a similar behavior between rectal doses and SSDE, suggesting that organ absorbed doses and SSDE values may be linearly dependent, with organ-specific linear coefficients. Further investigation in organ doses is necessary to evaluate this assumption.
APA, Harvard, Vancouver, ISO, and other styles
41

Barsanelli, Cristiane. "Métodos para implementação da dosimetria in vivo (dose de entrada) com dosímetros termoluminescentes na radioterapia externa com feixe de fóton." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-03052012-103720/.

Full text
Abstract:
Neste trabalho, estão descritos os métodos de seleção, calibração e de determinação dos fatores de correção, as características físicas dos dosímetros termoluminescentes, o procedimento de cálculo para converter a leitura do dosímetro em dose absorvida e a metodologia para se determinar a dose de entrada. Foram investigadas a praticidade e a utilidade das medidas de dose de entrada com os dosímetros termoluminescentes, bem como a exatidão e a reprodutibilidade no fornecimento da dose diária. As medidas de dose de entrada foram realizadas em cinco pacientes com diagnóstico de câncer de mama tratadas com um feixe de fótons de 6 MV. Não foram detectados grandes desvios entre a dose medida e a dose esperada (os valores concordaram em ± 5%), devido à excelente estabilidade do equipamento de tratamento, ao sistema automático de verificação e à boa exatidão no ajuste diário do tratamento. Uma boa precisão pode ser alcançada quando os fatores de correção para cada parâmetro de influência na resposta do dosímetro são cuidadosamente determinados e aplicados para converter o sinal termoluminescente em dose absorvida. O estudo demonstrou a viabilidade do uso dos dosímetros termoluminescentes para a dosimetria in vivo e sua utilidade como parte de um programa de garantia de qualidade em um serviço de radioterapia.
Selection, calibration procedure to convert TLD signal into absorbed dose and physical characteristics at the thermoluminescent dosimeters, as well as the determination of correction factors and the methodology to determine expected entrance dose, are described in this work. Practical aspects and the utility of entrance dose measures with thermoluminescent dosimeters were investigated, as well as the exactness and the reproducibility of the daily dose release. The entrance dose measures were performed in five patients with diagnosis of breast cancer treated with a 6 MV photon beam. The measured dose and the expected dose values agreed in ± 5%, due to excellent treatment equipment stability, to automatic verification system and the good exactness in the daily treatment adjustment. Good precision can be achieved when the correction factors for each parameter of influence in the dosimeter response are carefully determined and applied to convert the thermoluminescent signal into absorbed dose. The study demonstrates the viability of thermoluminescent dosimeters use for in vivo dosimetry and its utility as part of a quality assurance program in a radiation therapy service.
APA, Harvard, Vancouver, ISO, and other styles
42

Carmo, Lucas Sátiro do. "Dosimetria termoluminescente de altas doses de raios gama, raios beta, feixe de prótons e de nêutrons epitérmicos utilizando minerais naturais de silicatos e dosímetros de LiF: Mg, Cu, P (MCP)." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-09102015-084259/.

Full text
Abstract:
No mundo de hoje, onde o uso da radiação de diversas naturezas está generalizado, a quantificação da energia depositada por essas diferentes radiações se tornou uma atividade de grande importância, principalmente quando a faixa de energia é considerada elevada, estas altas energias de radiação estão presentes, geralmente, em aceleradores de partículas, reatores nucleares e em irradiadores industriais, por exemplo. Este trabalho tem como objetivo medir altas doses de radiação de raios gama, feixes de elétrons e feixes de prótons utilizando duas variedades de um silicato natural (água-marinha e goshenita) e medir altas doses de nêutrons epitérmicos de alta fluência utilizando dosímetros de Fluoreto de Lítio dopados com Mg, Cu e P (MCP). A técnica utilizada para medir a dose absorvida por esses materiais foi a termoluminescência. As irradiações com raios- γ provenientes de fontes de 60Co foram de 100 kGy a 2000 kGy para a água-marinha e de 600 kGy a 2000 kGy para a goshenita, os resultados de intensidade TL vs Dose mostram que a partir de certa dose - 250 kGy e 1234,8 kGy para água-marinha e goshenita, respectivamente - o sinal TL começa a decrescer. Foi observado neste trabalho que, estes materiais quando irradiados com tais doses e posteriormente irradiados com doses baixas de alguns Gys até cerca de 400-500 Gy, o sinal TL decresce regularmente, podendo ser utilizado na dosimetria das radiações nessa faixa de dose. Para a irradiação de feixe de prótons e de feixe de elétrons foram utilizados dosímetros em placa de goshenita e dosímetros de pastilhas de água-marinha, a carga do feixe de prótons vai de 20 a 216 μC e a dose do feixe de elétrons vai de 10 kGy a 70 kGy. As irradiações com nêutrons epitérmicos utilizando LiF: Mg, Cu, P foram realizadas no reator IEA-R1/IPEN com fluências de 1014 a 1017 n/cm² e a quantificação das doses absorvidas foram realizadas utilizando o método UHTR (Ultra High Temperature Ratio).
In the present days the usage of ionizing radiation from several different sources is spread all over the world. The measurement of the absorbed energy from these radiations became a very important task, mainly when the dose range is considered being in a very high level. These high energies of radiation are associated with particles accelerators, nuclear reactors and industrial irradiators, for example. This work is concerned for measuring high-doses of gamma radiation, electron beams and proton beams using two varieties of a natural silicate (aqua-marine and goshenite) and measuring effects of high-fluence neutrons using LiF: Mg, Cu, P (MCP) detectors. Thermoluminescence was employed to measure the absorbed dose for irradiations with gamma rays ranging from 100 kGy up to 2000 kGy for aquamarine and from 600 kGy and 2000 kGy for goshenite. The TL intensity reaches maximum at 250 kGy in aquamarine and at 1234 kGy for goshenite; this means that for doses larger than 250 kGy in aquamarine and 1234 kGy in goshenite the TL intensity drops. However, the descending part can be used in very high dose dosimetry. Furthermore, has been observed in this study that starting with aquamarine irradiated with 250 kGy and goshenite with 1234 kGy, the subsequent irradiation with doses from low to 400-500 Gy produces a regularly decreasing TL intensity, so that it can be used in radiation dosimetry from low to 400-500 Gy doses. For proton beams, goshenite were used. The beam charge ranges from 20 a 216 μC. For electron beams small pressed pellets of aquamarine were used. The dose ranges from 10 kGy to 70 kGy. The epithermal neutron irradiation was performed at IEA-R1 research reactor at IPEN and MCP-LiF detectors were used to measure the absorbed dose. A method called UHTR (Ultra High Temperature Ratio) was employed for calculating the amount of energy absorbed by the dosimeter. The fluence of epithermal neutrons ranges from 1014 a 1017 n/cm².
APA, Harvard, Vancouver, ISO, and other styles
43

CARMO, LUCAS S. do. "Dosimetria termoluminescente de altas doses de raios gama, raios beta, feixe de prótons e de nêutrons epitérmicos utilizando minerais naturais de silicatos e dosímetros de LiF: Mg, Cu, P (MCP)." reponame:Repositório Institucional do IPEN, 2015. http://repositorio.ipen.br:8080/xmlui/handle/123456789/25192.

Full text
Abstract:
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-11-12T10:02:52Z No. of bitstreams: 0
Made available in DSpace on 2015-11-12T10:02:52Z (GMT). No. of bitstreams: 0
Dissertação (Mestrado em Tecnologia Nuclear)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
44

Junot, Danilo Oliveira. "Aprimoramento de rotas e produção de dosímetros à base de CaSO4 com dopagens não usuais." Universidade Federal de Sergipe, 2017. http://ri.ufs.br:8080/xmlui/handle/123456789/5288.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
The widespread use of ionizing radiation in medicine and industry, associated with the known risks that this type of radiation can cause, has motivated the search for new radiation detectors, seeking improvements in the dosimetric characteristics and in the cost of production in comparison with commercial dosimeters disseminated. The motivation of this work is, therefore, to produce new thermoluminescent detectors through improved routes. Unusual elements in CaSO 4 matrix doping, such as terbium (Tb) and ytterbium (Yb), were used as dopants in this matrix, as well as the europium (Eu), the thulium (Tm) and the silver (Ag), resulting in samples of CaSO 4 :Eu,Tb, CaSO 4 :Tb,Yb, CaSO 4 :Tm,Ag and CaSO 4 :Eu,Ag that were prepared by means of an adaptation of the method developed by Yamashita (1971). The route of synthesis is based on the mixture of calcium carbonate (CaCO 3 ) and dopant oxide (except for silver, incorporated in the form of metalic nanoparticles) in a solution of sulfuric acid. The mixture is heated until all the acid evaporates and only the powder of the material remains. In this route, the sulfuric acid is collected and can be reused. The phosphors produced were characterized by X-ray diffraction and radioluminescence techniques. The silver particles, produced by the polyol method, were characterized by scanning electron microscopy. Composites were obtained from the addition of Teflon to the phosphors. The thermoluminescence (TL) and the optically stimulated luminescence (OSL) of the new materials produced were investigated. Thermoluminescent characteristics such as sensitivity, linearity, reproducibility, minimum detectable dose, kinetic order and fading were evaluated and discussed. The CaSO 4 :Tb,Eu composites showed TL glow curves with peaks at temperatures of 170 °C, 270 °C and 340 °C. The CaSO 4 :Tb,Yb composites presented TL glow curves with peaks at temperatures of 90 °C, 160 °C, 240 °C and 340 °C. CaSO 4 :Tm showed peaks at temperatures of 140 °C and 225 °C and the CaSO 4 :Tm,Ag presented peaks at temperatures of 140 °C, 280 °C and 380 °C. All composites showed a linear and reproducible dose response. The TL emission spectrum of the composites was also evaluated. The samples of calcium sulfate doped with europium and silver particles (CaSO 4 :Eu,Ag) showed great potential for applicability in the OSL dosimetry.
O amplo uso das radiações ionizantes na medicina e na indústria, associado aos riscos conhecidos que esse tipo de radiação pode provocar, tem motivado o desenvolvimento de novos detectores de radiação, buscando melhorias nas características dosimétricas e no custo de produção em comparação com os dosímetros comercialmente difundidos. A motivação deste trabalho foi, portanto, produzir novos detectores termoluminescentes a partir de rotas aprimoradas. Elementos não usuais na dopagem do CaSO 4 , como o térbio (Tb) e o itérbio (Yb), foram empregados como dopantes dessa matriz, assim como o európio (Eu), o túlio (Tm) e a prata (Ag), resultando em amostras de CaSO 4 :Eu,Tb, CaSO 4 :Tb,Yb, CaSO 4 :Tm,Ag e CaSO 4 :Eu,Ag, que foram preparadas por meio de uma adaptação do método desenvolvido por Yamashita et al. (1971). A rota de síntese baseia-se na mistura do carbonato de cálcio (CaCO 3 ) e do óxido dos dopantes (exceto para a prata, incorporada na forma de nanopartículas metálicas) numa solução de ácido sulfúrico. A mistura é aquecida até que todo o ácido evapore e reste somente o pó do material. Nessa rota, o ácido sulfúrico é recoletado e pode ser reutilizado. Os fósforos produzidos foram caracterizados por técnicas de difração de raios X e de radioluminescência. As partículas de prata, produzidas pelo método poliol, foram caracterizadas por microscopia eletrônica de varredura. Compósitos foram obtidos a partir da adição de Teflon aos fósforos. A termoluminescência (TL) e a luminescência opticamente estimulada (LOE) dos novos materiais produzidos foram investigadas. Características termoluminescentes como sensibilidade, linearidade, reprodutibilidade, dose mínima detectável, ordem de cinética e desvanecimento foram avaliadas e discutidas. Os compósitos de CaSO 4 :Tb,Eu apresentaram curvas de emissão TL com picos às temperaturas de 170 °C, 270 °C e 340 °C. Os compósitos de CaSO 4 :Tb,Yb apresentaram curvas de emissão TL com picos às temperaturas de 90 °C, 160 °C, 240 °C e 340 °C. O CaSO 4 :Tm apresentou picos em temperaturas de 140 °C e 225 °C. Já o CaSO 4 :Tm,Ag apresentou picos em temperaturas de 140 ºC, 280 ºC e 380 ºC. Todos os compósitos apresentaram respostas lineares à dose e reprodutíveis. Também foi avaliado o espectro de emissão TL dos compósitos. As amostras de sulfato de cálcio dopado com európio e partículas de prata (CaSO 4 :Eu,Ag) demonstraram grande potencial para aplicabilidade na dosimetria LOE.
APA, Harvard, Vancouver, ISO, and other styles
45

Freitas, Marcelo Baptista de. "Panorama das exposições médicas em radiologia convencional no Estado de São Paulo." Universidade de São Paulo, 2005. http://www.teses.usp.br/teses/disponiveis/43/43134/tde-17072009-145914/.

Full text
Abstract:
A dosimetria de pacientes associada à avaliação das condições de funcionamento dos equipamentos médicos e aos procedimentos empregados na realização dos exames, desempenha um papel fundamental no sistema de proteção radiológica das exposições médicas. Nesse sentido, foi realizado um levantamento em grande escala das doses recebidas pelos pacientes submetidos a exames radiológicos convencionais realizados em uma amostra representativa de estabelecimentos de saúde do estado de São Paulo. Nesse levantamento foi empregado um kit dosimétrico postal originalmente desenvolvido, que permitiu a determinação da dose de entrada na pele (DEP) através da técnica de dosimetria termoluminescente. Paralelamente foram realizadas visitas in-loco a uma sub-amostra de estabelecimentos, onde as condições de funcionamento dos equipamentos de raios X médicos e do sistema de imagem foram avaliadas empregando-se procedimentos e equipamentos já estabelecidos em protocolos de controle de qualidade. O estudo completou-se com a elaboração de um catálogo de espectros na faixa de energia do radiodiagnóstico, que, através de procedimento desenvolvido, permitiu inferir espectros equivalentes em equipamentos médicos. Na determinação dos espectros foi empregado um detector semicondutor de telureto de cádmio e zinco (CdZnTe), cujas curvas de eficiência e escape foram determinadas experimentalmente para realização do processo de correção dos espectros (stripping procedure). O processo de amostragem de estabelecimentos de saúde realizado neste estudo permitiu verificar a distribuição de equipamentos de diagnóstico por imagem e a freqüência de exames radiológicos no estado de São Paulo. A partir desses resultados foram escolhidos os exames de tórax, crânio (e seios da face) e coluna para avaliação de DEP, uma vez que os mesmos apresentam as maiores freqüências anuais de exames por 1.000 habitantes: 100, 46 e 29, respectivamente. Na técnica de amostragem dos estabelecimentos de saúde incluídos neste estudo foi empregado como critério de estratificação a quantidade anual de exames radiológicos associados ao município de localização do estabelecimento. Do total de 200 estabelecimentos sorteados, 50 participaram da primeira etapa e 38 da segunda. Um total de 83 salas de exames (ou equipamentos) e 868 pacientes foram incluídos, e um conjunto de 1415 valores de DEP foi determinado. O resultado da distribuição dos valores de DEP permitiu determinar os chamados níveis de referência, que, no caso de pacientes adultos, se mostraram bastante semelhantes aos encontrados em outros estudos internacionais. No caso de pacientes infantis, a situação é bem diferente, obtendo-se valores pelo menos 2 vezes superiores a outros recomendados internacionalmente para a radiografia infantil mais freqüente (tórax). Esse fato sugere que as práticas empregadas na realização dos exames devem ser revisadas e que recomendações específicas a esse grupo de pacientes, a partir de estudos dirigidos, sejam publicadas. Constatou-se também alguns casos de DEP elevada pelo uso desnecessário de radioscopia de localização. Os testes de desempenho dos equipamentos e a avaliação das imagens realizadas sugerem que há possibilidade de melhoria das condições de realização dos exames, sem perda de informação diagnóstica presente na imagem e com redução das doses. Alguns espectros de raios X determinados experimentalmente apresentaram divergência em relação a outros catálogos já estabelecidos, numa faixa específica de energia do espectro (entre 25 e 40 keV). Para a sua utilização em situações práticas há necessidade de algumas correções na curva de eficiência, o que não inviabiliza a metodologia e os procedimentos estabelecidos. De forma geral, os resultados encontrados neste estudo permitem traçar um panorama das exposições médicas em radiologia convencional no estado de São Paulo, contribuindo para o aperfeiçoamento de futuras pesquisas que sejam realizadas na área, ou mesmo, para a implementação de políticas públicas.
Patients dosimetry, associated with the assessment of the performance of the radiological equipment and of the series of procedures employed in the accomplishment of the examinations, plays fundamental role in the radiation protection system of medical exposures. Therefore, a large-scale survey of absorbed doses was carried out in health services localized in the state of São Paulo, including patients submitted to conventional radiological examinations. In this survey a postal dosimetric kit, originally developed, was employed. It allows the evaluation of the entrance surface dose (ESD) to patients with thermoluminescence dosimeters. Also a series visits to a sub-sample of services was carried out, giving rise to the in-loco evaluation of the performance of the medical x-ray equipment and of the image system, using procedures and equipments already established in protocols of quality control. The study is completed with the elaboration of a catalogue of x-ray spectra, which provides means to infer the spectra generated by medical x-ray equipments. Measurements of x-ray spectra were carried out with a cadmium zinc telluride detector (CdZnTe), and the stripping procedure was performed taking into account both the contributions of efficiency and x-ray escape fraction, experimentally determined in this work. The stratified sampling technique furnished important data on the distribution of equipments and the annual frequency of examinations performed in the state of São Paulo. From these results radiological examinations of the chest, skull and sinus, and spine were selected for the evaluation of ESD, as their annual frequencies are the highest observed: 100, 46 and 29 per thousand inhabitants, respectively. The number of x-ray examinations carried out annually in the cities of the state was employed as the stratification criterion to construct the sample. From a total of 200 health services sampled, 50 agreed to participate of the first stage, and 38 of the second. A total of 83 rooms (or x-ray equipments) and 868 patients was included, and a set of 1415 values of ESD was measured. Diagnostic reference levels were determined with the outcomes of the distribution of ESD. For adult patients, the reference levels achieved are very similar to others obtained in international surveys. However, as far as pediatric patients are concerned, the situation is very different: the values found in this survey are twice larger than the international recommendations to chest radiography of children. This points out that the practices need to be revised and that specific recommendations to this patient group, following specific surveys, should be provided. Also, a series of high ESD values due to unnecessary localizing radioscopy were detected among our data. The results of the equipment performance tests and of the evaluation of image quality suggest that it is possible to improve the conditions of the examinations and to reduce doses to patients, without impairment of the diagnostic information. Some of the experimentally determined x-ray spectra show a discrepancy, when compared to other catalogue spectra, in a particular energy range 25 to 40 keV. The practical application of them will require some corrections in the efficiency curve, but the established methodology and procedures remain legitimate. In an extensive approach, the results of this study supply a panorama of medical exposures in conventional radiology in the state of São Paulo, contributing with resources to future research in the field and also to governmental actions.
APA, Harvard, Vancouver, ISO, and other styles
46

Bitencourt, José Francisco Sousa. "Produção e caracterização de óxido de alumínio, aluminato de magnésio e filmes finos de óxido de alumínio para aplicações em radioterapia e dosimetria ambiental." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/3/3140/tde-11072014-014000/.

Full text
Abstract:
Medidas de Termoluminescência (TL), Luminescência Opticamente Estimulada (LOE), EPR (Ressonância Paramagnética de Elétron) e RL (Radioluminescência) foram obtidas de amostras de óxido de alumínio e óxido de alumínio dopado com magnésio. As amostras foram calcinadas em três diferentes temperaturas (1100, 1350 e 1600°C) para observar a variação do comportamento das propriedades luminescentes. Ao final, constatou-se que a temperatura de calcinação é um parâmetro de grande importância para a produção de materiais dosimétricos, pois a amostra com melhores resultados LOE foi o material sem dopante tratada a 1600°C. Em trabalhos anteriores, a composição de óxido de alumínio dopado com magnésio havia apresentado nanoestruturas de aluminato de magnésio, observadas através de Microscopia Eletrônica de Transmissão (MET), que influenciaram a sensibilidade do material à radiação. Amostras de aluminato de magnésio puro e dopado com terras raras foram obtidas na forma de pó e calcinadas a 1100, 1350 e 1600°C. Medidas de TL e LOE de amostras irradiadas com fonte de partículas foram analisadas e comparadas com resultados de EPR e Difração de Raios-X (DRX). Como resultado, foi concluído que, nas condições trabalhadas, somente o elemento gadolínio proporcionou aumento de emissão LOE e TL no espectro visível. DRX indicou a formação dos compostos Al5Er3O12 e Al5Yb3O12; gadolínio e európio também formaram estruturas secundárias que não puderam ser determinadas. A partir do óxido de alumínio em pó, foram produzidos alvos para deposição de filmes finos empregando um sistema de sputtering magnetron e lâminas de silício monocristalino (100) tipo P para substrato. Parâmetros de deposição e de tratamento térmico foram variados de modo a produzir amostras com diferentes características. Curvas de TL foram levantadas e analisadas com relação aos resultados de DRX. Imagens de Microscopia Eletrônica de Varredura (MEV) foram obtidas de algumas amostras para visualizar o estado dos filmes depositados após tratamentos térmicos de 500 e 1100°C. Resultados mostraram a formação de picos de difração de a-Al2O3 em algumas das amostras espessas. Medidas de TL de amostras expostas à radiação ambiente exibiram picos de emissão em posições que variaram de acordo com a composição e espessura do filme depositado.
Thermoluminecent (TL), Optically Stimulated Luminescence (OSL), EPR (Electron spin Resonance) and Radioluminescence (RL) measurements were obtained from aluminum oxide and magnesium doped aluminum oxide samples. The samples were calcinated at three different temperatures (1100, 1350 and 1600°C) in order to observe variation of luminescent properties. As results, it was found that the calcination temperature is of great importance in the production of dosimetric materials, since the undoped sample calcinated at 1600°C showed the highest sensibility. In early works, magnesium doped aluminum oxide samples exhibited the formation of nanostructured layer composed by magnesium aluminate, observed using Transmission Electron Microscopy (TEM), which induced an increase of the luminescent properties. Samples of undoped and rare-earths doped magnesium aluminate, calcinated at 1100, 1350 and 1600°C, were produced. TL and OSL measurements were obtained from irradiated aliquots, analyzed and compared to EPR and XRD results. Results showed that, under the parameters used in this work, only gadolinium doped samples exhibited increase in TL and OSL emissions. XRD indicated the formation of Al5Er3O12 and Al5Yb3O12 structures in doped samples; gadolinium and europium doped samples also showed new structures, which couldnt be identified. Powder aluminum oxide was used to produce deposition targets, which were employed in the deposition of thin films over P type monocrystalline silicon (100) wafers. Variations of deposition parameters and heat treatment induced the formation of thin films with different characteristics, observed by XRD and luminescent analysis (TL). XRD results indicated the occurrence of alpha-Al2O3 in some of the thick films. Samples exposed to natural radiation produced TL emission in the visible spectrum.
APA, Harvard, Vancouver, ISO, and other styles
47

Bravim, Amanda. "Aplicação das técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) na determinação de curvas de isodose em uma simulação de tratamento de câncer pela técnica de radioterapia em arco modulado volumétrico - VMAT." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-30072015-132845/.

Full text
Abstract:
A Radioterapia em Arco Modulado Volumétrico (VMAT) é uma técnica avançada de Radioterapia de Intensidade Modulada (IMRT). Esse avanço na técnica é devido à rotação contínua do gantry juntamente com a modulação do feixe de radiação proporcionando um tempo menor no tratamento do paciente. O objetivo desse trabalho é a verificação de curvas de isodose em uma simulação de um tratamento de vértebra com proteção de medula espinhal utilizando as técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) e os dosímetros de LiF:Mg,Ti (TLD-100), CaSO4:Dy e Al2O3:C e microdosímetros de LiF:Mg,Ti (TLD-100). Os dosímetros foram caracterizados com a utilização de placas de PMMA de 30x30 cm2 e diversas espessuras. Todas as irradiações foram feitas utilizando o acelerador linear Truebeam STx da Varian do Hospital Israelita Albert Einstein, com feixe de fótons de 6 MV. Após a caracterização dos dosímetros, os mesmos foram irradiados seguindo a simulação do planejamento escolhido e utilizando um objeto simulador de PMMA produzido para medidas de VMAT. Essa irradiação teve como finalidade verificar através das duas técnicas de dosimetria as curvas de isodose dessa simulação de tratamento. Todos os tipos de dosímetros apresentaram resultados satisfatórios na verificação das curvas de isodose utilizando ambas as técnicas de dosimetria. Porém, analisando a complexidade das curvas de isodose e a possibilidade das curvas estarem muito próximas, o microdosímetro de LiF:Mg,Ti se mostrou o mais apropriado para o uso devido à suas pequenas dimensões. Em relação à melhor técnica, como ambas apresentaram resultados satisfatórios, a técnica TL é a que apresenta menor complexidade em ser utilizada, pois a maioria dos Departamentos de Radioterapia já possuem um Laboratório para leitura TL. A técnica OSL exige mais cuidados e maior investimento do Departamento.
The Volumetric Modulated Arc Therapy (VMAT) is an advance technique of Intensity Modulated Radiation Therapy (IMRT). This progress is due to the continuous gantry rotation with the radiation beam modulation providing lower time of the patient treatment. This research aimed the verification of the isodose curves in a simulation of a vertebra treatment with spinal cord protection using the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques and theLiF:Mg,Ti (TLD-100), CaSO4:Dy and Al2O3:C dosimeters and LiF:Mg,Ti microdosimeters (TLD-100). The dosimeters were characterized using PMMA plates of 30x30x30 cm3 and different thickness. All irradiations were done using Truebeam STx linear accelerator of Hospital Israelita Albert Einstein, with 6 MV photons beam. After the dosimeter characterization, they were irradiated according the specific planning simulation and using a PMMA phantom developed to VMAT measurements. This irradiation aimed to verify the isodose curves of the treatment simulation using the two dosimetry techniques. All types of dosimeters showed satisfactory results to determine the dose distribution but analysing the complexity of the isodose curves and the proximity of them, the LiF:Mg,Ti microdosimeter showed the most appropriate for use due to its small dimensions. Regarding the best technique, as both technique showed satisfactory results, the TL technique presents less complex to be used because the most of the radiotherapy departments already have a TL laboratory. The OSL technique requires more care and greater investment in the hospital.
APA, Harvard, Vancouver, ISO, and other styles
48

BRAVIM, AMANDA. "Aplicação das técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) na determinação de curvas de isodose em uma simulação de tratamento de câncer pela técnica de radioterapia em arco modulado volumétrico – VMAT." reponame:Repositório Institucional do IPEN, 2015. http://repositorio.ipen.br:8080/xmlui/handle/123456789/23906.

Full text
Abstract:
Submitted by Maria Eneide de Souza Araujo (mearaujo@ipen.br) on 2015-09-02T12:47:25Z No. of bitstreams: 0
Made available in DSpace on 2015-09-02T12:47:25Z (GMT). No. of bitstreams: 0
Tese (Doutorado em Tecnologia Nuclear)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
49

Arruda, Emerson Martins [UNESP]. "Contribuição da dinâmica morfoestrutural e morfoescultural na estruturação da bacia do Ribeirão Entupido, complexo alcalino do Passa Quatro - SP." Universidade Estadual Paulista (UNESP), 2008. http://hdl.handle.net/11449/104413.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:33:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-04-03Bitstream added on 2014-06-13T19:04:03Z : No. of bitstreams: 1 arruda_em_dr_rcla.pdf: 9662595 bytes, checksum: 0ed9158bd4d58632c075670ed3c2f2ba (MD5)
A pesquisa analisa os eventos deposicionais, esculturadores do relevo, na bacia do Ribeirão Entupido, Complexo Alcalino do Passa Quatro, Estado de São Paulo, a partir do estudo dos depósitos recentes da área. Além da análise geomorfológica na referida unidade espacial, a pesquisa buscou estabelecer a idade absoluta de deposição de algumas unidades sedimentares estruturadoras do relevo e os mecanismos envolvidos na sua gênese. Neste contexto, utilizou-se datações por Luminescência Opticamente Estimulada (LOE) e Termoluminescência (TL). Os depósitos sedimentares foram estudados a partir da abordagem morfoestratigráfica. O cruzamento de dados morfoesculturais e morfoestruturais e de datação absoluta permitiu estabelecer quais mecanismos, atuantes ao longo do último milhão de anos, comandaram a morfogênese na bacia em foco. A determinação da morfogênese permitiu definir a susceptibilidade do relevo às mudanças ambientais, inclusive às intervenções antrópicas. Os depósitos sedimentares apresentaram idades vinculadas ao Pleistoceno Superior (61.500 anos) e Holoceno (650 anos) representando, portanto, eventos diferenciados no desenvolvimento e localização deste ambientes. A complexidade da paisagem na bacia do Ribeirão Entupido envolve justamente esta interdigitação de materiais de idades diversas que compõem o mesmo ambiente de deposição, interferindo conjuntamente a tectônica e as condições climáticas, a priori, na espacialização dos depósitos e nas características dos sedimentos.
This research of doctor’s grade analyze the depositional and sculptural events, at stream Entupido basin, Passa Quatro Alkalin Complex, Estate of São Paulo, from the study of recent deposits.Beyond the geomorphologycal analysis at referred spacial unit, this research tried to establish the absolute age of some sedimentary units that structure the relief and the mechanism involved in its genesis. The dating method of Optically Stimulated Luminescence (OSL) Thermoluminescence (TL) was used in that context.The sedimentary deposits were studied by morphostratigraphic approach. The crossing of mophosculptural and moprostructural data and absoluting dating allow establish wich mechanism, acting through the last million years, commanded the morphogenesis process at the basin.The determination of morfogenesis allowed define the susceptilidy of relief to ambiental changes, including antropic intervention. The sedimentary deposits show ages linked at Up Pleistocene (61.500 years) and Holocene (650 years), showing, therefore, differenced events in development and localization of this environment.The landscape complexity in stream Entupido basin, involves precisely this interdigitation of materials and different ages that compose the same depositional environment, interfering jointly tectonic and climatic conditions, in prior, at specialization of deposits and sedimentary characteristics.
APA, Harvard, Vancouver, ISO, and other styles
50

Rojas, Diana Maritza Cuevas. "Dosimetria 3D de um tratamento simulado de próstata na presença de próteses femorais metálicas." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-11072017-094424/.

Full text
Abstract:
Historicamente a radioterapia é divida em radioterapia externa, braquiterapia e radioisotopoterapia sistemática. As diferenças entre as três está no posicionamento da fonte de radiação com respeito ao corpo humano. Na radioterapia externa a fonte fica a uma certa distância do paciente, já no caso da braquiterapia as fontes podem ser inseridas dentro de cavidades do corpo ou implantadas diretamente nos tecidos. Na radioisotopoterapia sistemática isótopos radiativos são administrados por via oral ou venosa. Dessas três a radioterapia externa é a mais usada pois, ela permite realizar planejamentos de radioterapia em três dimensões (3D), partindo inicialmente de uma tomografia computadorizada da região do tumor. O planejamento baseado na tomografia computadorizada permite que a distribuição da radiação nos tecidos seja feito com mais precisão evitando assim, que os tecidos sadios sejam afetados. Nesse trabalho a radioterapia externa convencional, foi implementada e executada para um tratamento de próstata com implantes metálicos, usando 4 campos de irradiação (0, 90, 180, 270 graus) e uma dose total planejada de 70 Gy fracionada em 35 sessões, cada uma com 2 Gy. Em qualquer tipo de tratamento que envolva a radiação ionizante é exigido um controle de qualidade para assim, determinar se a dose inicialmente planejada será entregue ou não ao tumor. Idealmente deveria ser implementado um controle de qualidade em três dimensões mas, até o momento não há um dosímetro 3D consolidado na rotina clinica. No entanto, o uso de géis poliméricos associados à técnica de leitura de dose com imagem de ressonância magnética (IRM) possibilita a dosimetria tridimensional. Nesse contexto, é aplicada a dosimetria 3D usando para isso, o gel magic com formaldeído (magic-f). Além da dosimetria 3D, foram realizadas medidas de dose absorvida por meio de dosimetria pontual, para tal fim são utilizados dosímetros termoluminescentes e de alanina. Na avaliação da distribuição de dose feita pelo planejamento e a medida com o gel é usado a análise gama (3%/3mm), neste caso, a distribuição de dose medida concorda com a distribuição de dose planejada TPS. A análise gama apresenta um porcentagem de aprovação do 93%. Os valores de dose absorvida na interface osso-metal determinados pelos dosímetros TL apresentam um aumento de 1,73 Gy na região do osso sacro e outros aumentos entre o 0,16 e 0,33 Gy foram encontrados em regiões como a cabeça do fêmur e quadril. Esses aumentos na dose foram só para duas sessões com doses entregadas ao fantom de 2 Gy. De igual maneira para os dosímetros de alanina se encontro um aumento na dose de 1,22 e 2,42 Gy na região do osso sacro. O planejamento feito nesse caso foi de 6 Gy. Os resultados evidentemente mostram como as inomogeneidades de um material com número atómico alto, gera perturbações sobre as distribuições de dose inicialmente planejadas.
Historically, Radiotherapy is divided into external radiotherapy, brachytherapy and systemic radioisotopotherapy. The difference between the three lies in the position of the radiation source regarding the human body. In external radiotherapy the source is at a certain distances of patient, and in the case of brachytherapy, this source can be inserted into cavities of body or implanted directly in the tissues. In systemic radiotherapy radioisotopes are administered orally or intravenously. Of these three, external radiotherapy is the most used because it allows planning of radiotherapy in three dimensions (3D), starting from a CT scan of the tumor region. Computed tomography planning allows the distribution of radiation in the tissues to be more accurate thus avoiding, that healthy tissues are affected. In our case, conventional external radiotherapy was implemented and executed for a prostate treatment with metal implants, using 4 irradiation fields (0, 90, 180, 270 degrees) and a total planned dose of 70 Gy fractioned in 35 sessions each with 2 Gy. In any type of treatment involving ionizing radiation, quality control (QC) is required to determine if the dose initially planned is delivered or not to the tumor. Ideally, a quality control should be implemented in three dimensions but to date there is no consolidated 3D dosimeter system in the clinic routine. However, the used of polymeric gels associated with magnetic resonance image (IRM) allow three-tridimensional dosimetry. In this context, the 3D dosimetry is applied using the magic gel with formaldehyde (magic-f). In addition to 3D dosimetry, absorbed dose measurements were performed by means of a dose in a point, using thermoluminescent and alanine dosimeters. The comparison of dose distributions calculated by TPS and measured in the gel was made using by gamma analysis (3% / 3mm), in this case, the distribution of dose measurement agrees with the distributions expected by TPS. The analysis shows a percentage of approval of 93%. The absorbed dose values at the bone-metal interface determined by the TL dosimeters, presented a 1.73 Gy increase in the region of the sacral bone, and another increases between 0,16 and 0,33 Gy were found in the regions as the head of the femur and the hip. These dose increases were only for two sessions with doses delivered to the phanton of 2 Gy. Similarly for alanine dosimeters were found increases in the dose of 1.22 and 2.42 Gy in the region of sacral bone. The planning done in this case was 6 Gy. The results evidently show how the inomogeneities of a material with a high atomic number generate disturbances over the initially planned dose distributions.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography