Academic literature on the topic 'Système de suivi basé sur les ultrasons'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Système de suivi basé sur les ultrasons.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Système de suivi basé sur les ultrasons":
Méric, S., F. Nouvel, R. Agarini, T. Bunouf, Q. Guellaen, G. Le Bouhart, M. Meilhat, et al. "Système de surveillance de la qualité de l’air basé sur des capteurs embarqués sur vélo : projet AIR’O X AIR BREIZH." J3eA 21 (2022): 1026. http://dx.doi.org/10.1051/j3ea/20221026.
Baidada, Mohamed, Khalifa Mansouri, and Franck Poirier. "Vers une utilisation des TIC dans la formation des ressources humaines travaillant dans le domaine de l'éducation et la formation." Journal of Quality in Education 5, no. 5BIS (November 11, 2014): 7. http://dx.doi.org/10.37870/joqie.v5i5bis.30.
Vandenberghe, Hélène. "Méningoencéphalites d’origine inconnue chez le chien." Le Nouveau Praticien Vétérinaire canine & féline 19 (December 2022): 92–100. http://dx.doi.org/10.1051/npvcafe/2023014.
Ascone, Corentin, and Frédéric Vanderhaegen. "Rétro-ingénierie orientée par les usages de systèmes conversationnels : un cadre applicatif combinant pédagogie active et jeu sérieux." J3eA 22 (2023): 1002. http://dx.doi.org/10.1051/j3ea/20231002.
Fillol, Erwann, Frédéric Ham, and Alex Orenstein. "Système d’information et de modélisation de la vulnérabilité pastorale pour la gestion et la prévention des crises au sahel." Revue d’élevage et de médecine vétérinaire des pays tropicaux 73, no. 3 (September 23, 2020): 169–77. http://dx.doi.org/10.19182/remvt.31903.
Tapsoba, Yann, Eustache Ndokabilya, Jean-Claude Wema, Thomas Engels, and Élisabeth Paul. "Cartographie et analyse du financement de la santé dans la province du Sud-Kivu (RDC)." Santé Publique Vol. 35, no. 3 (October 12, 2023): 315–28. http://dx.doi.org/10.3917/spub.233.0315.
Lebeau, Aimé. "Les grands utilisateurs des services psychiatriques d’urgence dans la région du Montréal métropolitain." Santé mentale au Québec 7, no. 1 (June 13, 2006): 57–74. http://dx.doi.org/10.7202/030125ar.
Rih, Fadwa, Khalid Limamy, and Wafae El Alem. "La Mesure de la Motivation chez les Jeunes Créatifs et Innovants dans le Système Éducatif Marocain : Validation de l’Échelle de Mesure WPI-E." European Scientific Journal, ESJ 19, no. 10 (April 29, 2023): 118. http://dx.doi.org/10.19044/esj.2023.v19n10p118.
Tremblay, Marc-Adélard. "L'anthropologie de la santé en tant que représentation." Articles - Le quotidien 23, no. 3 (April 12, 2005): 253–73. http://dx.doi.org/10.7202/055985ar.
Ojigi, M. L., J. D. Dodo, and Y. D. Opaluwa. "GNSS Sky Visibility Planning and Dilution of Precision Analysis for EOS Ground Station Selection for Nigeria Space Programme." Journal of Geospatial Science and Technology 1, no. 1 (November 1, 2014): 70–93. http://dx.doi.org/10.54222/afrigist/jgst/v1i1.5.
Dissertations / Theses on the topic "Système de suivi basé sur les ultrasons":
Zarader, Pierre. "Transcranial ultrasound tracking of a neurosurgical microrobot." Electronic Thesis or Diss., Sorbonne université, 2024. http://www.theses.fr/2024SORUS054.
With the aim of treating brain tumors difficult to access with current surgical tools, Robeauté is developing an innovative microrobot to navigate deep brain areas with minimal invasiveness. The aim of this thesis was to develop and validate a transcranial ultrasound-based tracking system for the microrobot, in order to be able to implement robotic commands and thus guarantee both the safety and the effectiveness of the intervention.The proposed approach consists in positioning three ultrasound emitters on the patient's head, and embedding an ultrasound receiver on the microrobot. Knowing the speed of sound in biological tissue and the skull thickness crossed, it is possible to estimate the distances from the emitters to the receiver by time-of-flight measurements, and to deduce its 3D position by trilateration. A proof of concept was first carried out using a skull phantom of constant thickness, demonstrating submillimeter localization accuracy. The system was then evaluated using a calvaria phantom whose thickness and speed of sound in front of each emitter were deduced by CT scan. The system demonstrated an mean localization accuracy of 1.5 mm, i.e. a degradation in accuracy of 1 mm compared with the tracking through the skull phantom of constant thickness, explained by the uncertainty brought by the heterogeneous shape of the calvaria. Finally, three preclinical tests, without the possibility of assessing localization error, were carried out: (i) a post-mortem test on a human, (ii) a post-mortem test on a ewe, (iii) and an in vivo test on a ewe.Further improvements to the tracking system have been proposed, such as (i) the use of CT scan-based transcranial ultrasound propagation simulation to take account of skull heterogeneities, (ii) the miniaturization of the ultrasound sensor embedded in the microrobot, (iii) as well as the integration of ultrasound imaging to visualize local vascularization around the microrobot, thereby reducing the risk of lesions and detecting possible pathological angiogenesis
Geraudie, Vincent. "Système d'aide à la conduite des procédés viticoles et oenologiques, basé sur l'utilisation d'un capteur piéton de suivi de maturité." Montpellier SupAgro, 2009. http://www.theses.fr/2009NSAM0025.