Academic literature on the topic 'Spectrométrie en énergie et de masse'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Spectrométrie en énergie et de masse.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Spectrométrie en énergie et de masse":

1

Baudin, Bruno. "Protéomique et spectrométrie de masse." Revue Francophone des Laboratoires 2011, no. 437 (December 2011): 31–40. http://dx.doi.org/10.1016/s1773-035x(11)71210-2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Gravet, A., and M. Gessier. "Spectrométrie de masse et microbiologie." Immuno-analyse & Biologie Spécialisée 28, no. 5-6 (October 2013): 297–308. http://dx.doi.org/10.1016/j.immbio.2013.09.003.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Beaugrand, CG. "Plasmas, ions et spectrométrie de masse." Journal de Chimie Physique 90 (1993): 1407–10. http://dx.doi.org/10.1051/jcp/1993901407.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Moussa, Fathi, Jean-François Benoist, Elizabeth Thioulouse, Marie-Clotilde Berthe, and Rémy Couderc. "Spectrométrie de masse et maladies métaboliques héréditaires." Revue Francophone des Laboratoires 2011, no. 437 (December 2011): 65–72. http://dx.doi.org/10.1016/s1773-035x(11)71213-8.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Bourlés, Didier L., Quentin Simon, and Nicolas Thouveny. "La spectrométrie de masse par accélérateur." Reflets de la physique, no. 66 (July 2020): 16–21. http://dx.doi.org/10.1051/refdp/202066016.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
L’étude des nucléides cosmogéniques et leur application aux géosciences débutent dans les années 1980, avec le développement de spectromètres de masse par accélération dédiés. Depuis 2007, grâce à l’instrument national ASTER (Accélérateur pour les Sciences de la Terre, Environnement, Risques) du CEREGE, des progrès majeurs ont été réalisés. Ils ont permis la quantification jusqu’alors impossible de nombreux processus géophysiques. Parmi ces avancées, la restitution fidèle du champ magnétique terrestre pendant le dernier million d’années a été rendu possible par les mesures de concentration du béryllium-10 (10Be) atmosphérique.
6

Baron, S. "Diagnostic de l’hyperaldostéronisme primaire et spectrométrie de masse." Annales d'Endocrinologie 82, no. 5 (October 2021): 224. http://dx.doi.org/10.1016/j.ando.2021.07.016.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Emile, Carole. "Spectrométrie de masse et hormonologie : le futur des immunodosages ?" Option/Bio 25, no. 517 (November 2014): 19–20. http://dx.doi.org/10.1016/s0992-5945(14)71995-6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Marinach-Patrice, C., C. Pionneau, and D. Mazier. "Spectrométrie de masse en biologie médicale: principes et applications." Bio tribune magazine 40, no. 1 (December 2011): 4–12. http://dx.doi.org/10.1007/s11834-011-0061-9.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Dahraoui, Souhail, Soukaina El Abbassi, Sara Kaissi, Hafida Naoui, Laila Boumhil, Maryem Iken, Azeddine Ibrahimy, and Badre Eddine Lmimouni. "Spectrométrie de masse MALDI-TOF et biomarqueurs de l’infection aspergillaire." Journal de Mycologie Médicale 27, no. 3 (September 2017): e43. http://dx.doi.org/10.1016/j.mycmed.2017.04.099.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Ingrand, J. "La spectrométrie de masse et ses principales applications en biologie médicale." Immuno-analyse & Biologie Spécialisée 27, no. 2 (April 2012): 47–53. http://dx.doi.org/10.1016/j.immbio.2012.01.008.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Spectrométrie en énergie et de masse":

1

Steichen, Valentin. "Développement d’un analyseur en énergie pour la caractérisation des hautes atmosphères neutres et ionisées terrestre et planétaires." Electronic Thesis or Diss., Sorbonne université, 2023. http://www.theses.fr/2023SORUS635.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
L'étude de la dynamique des particules dans la thermosphère - ionosphère et dans l'exosphère des corps du système solaire permet d'approfondir notre compréhension de ces régions critiques qui sont l’interface entre une planète et l'espace. Le but de ma thèse était de développer, construire et tester un analyseur en énergie pour l'étude des hautes atmosphères planétaires : INEA (Ion and Neutral Energy Analyser). L'instrument vise à mesurer la structure énergétique des constituants neutres et ioniques présents dans cette région. Pour réaliser cette tâche difficile, INEA s'appuie sur deux concepts : une source d'ions innovante, basée sur l’utilisation de nanotubes de carbone comme émetteur d'électrons et un analyseur en énergie électrostatique, capable d'imager directement la distribution en énergie des particules. Au cours de ces trois années de thèse, un modèle numérique de INEA a été développé afin de répondre aux objectifs instrumentaux imposés par les mesures nécessaires à la caractérisation des hautes atmosphères. Parallèlement, j'ai travaillé au développement d'une source d'ionisation, également nécessaire au fonctionnement optimal de INEA, basée sur l'utilisation de nanotubes de carbone comme émetteurs d'électrons. Le développement du détecteur, une autre partie importante de l'instrument, a également été réalisé. Suite à la modélisation numérique et aux travaux réalisés sur les différentes parties de l'instrument, un premier prototype d’INEA a été conçu et assemblé, ce prototype étant actuellement testé. Avec le travail réalisé au cours de cette thèse, nous avons pu proposer deux instruments pour de futures missions spatiales : M-INEA sur la mission M-MATISSE proposé pour l'appel à projet M7 de l'ESA, récemment sélectionnée pour une phase A jusqu’en 2026, et PSEE, un émetteur d'électrons dédié au contrôle de PRELUDE SAT ; un CubeSat de 6U développé par deux universités japonaises devant être lancé mi-2025
Studying the dynamic of particles in the thermosphere – ionosphere and in the exosphere of bodies in the Solar System allows to deepen our understanding of these critical regions that are the bridge between a planet and space. The aim of my thesis was to develop, build and test a neutral particles energy analyser for studying the upper planetary atmospheres: INEA (Ion and Neutral Energy Analyser). The instrument aims to measure the energy structure of the neutral and ion constituents present in the upper atmosphere. To achieve this challenging task, INEA relies on two concepts: an innovative ion source that is based on a carbon nanotube array as an electron emitter and an electrostatic energy analyser which is able to image directly the energy distribution of the particles. During these three years of thesis, a numerical model of INEA was developed in order to meet the instrumental objectives imposed by the measurements needed to characterize the upper atmospheres. At the same time, I have been working on the development of an ion source, also necessary for the optimal operation of INEA, based on the use of carbon nanotubes as electron emitters. The development of the detector, another important part of the instrument has also been conducted. Following the numerical modelling and the work achieved on the different parts of the instrument, a first prototype of INEA has been designed and assembled. This prototype being currently tested. With the work achieved during this thesis, we have been able to propose two instruments for future space missions: M-INEA on the M-MATISSE mission proposed for the ESA M7 call for project, recently selected for a phase A study up to mid-2026, and PSEE, an electron emitter dedicated to the control of PRELUDE SAT, a 6U CubeSat developed by two Japanese universities scheduled to be launched mid-2025
2

Hue-Faucheur, Nathalie. "Dissociation en phase gazeuse d'ions organiques complexes par collision de haute énergie et spectrométrie de masse tandem." Paris 11, 2002. http://www.theses.fr/2002PA112258.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Les techniques d'ionisation par désorption d'ions, qui procèdent du bombardement par des ions césium accélérés (LSIMS) ou de l'électronébulisation d'une solution à pression atmosphérique (electrospray, ESI), couplées à un analyseur de masse tandem à secteurs magnétiques et électrostatiques, ont été utilisées lors de ce travail de thèse. De la comparaison des spectres enregistrés après activation collisionnelle dans le régime des hautes énergies (de l'ordre du kiloélectronvolt) des espèces ioniques générées par l'une ou l'autre de ces méthodes d'ionisation, il résulte que le "mode de fabrication" des ions joue un rôle déterminant dans la dissociation selon des processus de fragmentation dite "à charge piégée" (CRF, charge-remote fragmentation). En effet, la quantité d'énergie interne que possède le précurseur avant la collision affecte considérablement le comportement de dissociation après l'étape d'activation collisionnelle. La spectrométrie de masse tandem associée à l'activation collisionnelle de haute énergie (CID MS/MS) et appliquée à des précurseurs désorbés en LSIMS ou ESI a également permis d'élucider la structure de divers composés naturels, en mélange complexe et en faible quantité. Il a ainsi été possible de déterminer de façon non ambigue͏̈ la position des insaturations ou ramifications au sein de molécules qui comportent une longue chaîne aliphatique: des dérivés de la sérotonine, des acétogénines et des glycosphingolipides, grâce à l'observation d'ions-fragments résultant de processus de type CRF, très spécifiques et hautement informatifs. Par ailleurs, les structures de lipopeptides cycliques de la famille des surfactines ainsi que d'oligosaccharides qui possèdent une fonction alditol et un groupement acide carboxylique ont été caractérisées
The ionization techniques which proceed from the bombardment of the sample by fast caesium ions (LSIMS) or from the electronebulization of a solution at atmospheric pressure (electrospray, ESI) have been used during this thesis in association with a multi-sectors tandem mass analyzer. From comparison between MS/MS spectra acquired after high energy collisional activation (in the order of kiloelectronvolt) of ionic species arising from one of these ionization methods, it has been shown that the "production mode" of the ions plays a crucial role in dissociation processes via charge-remote fragmentation (CRF). The internal energy of the precursor ions before the collision affects indeed significantly the dissociation behavior after the collisional activation step. Tandem mass spectrometry in combination with high energy collisional activation (CID-MS/MS) and applied to parent ions generated in the LSIMS or ESI ion source allowed the structural elucidation of various natural compounds in complex mixtures and small amounts. It was thus possible to establish unambiguously the double bonds location or branching pattern for aliphatic long chain molecules: serotonin derivatives, acetogenines and glycosphingolipids, with the occurrence of CRF fragment ions that are very specific and highly informative. In addition the structures of cyclic lipopeptides from the surfactine family and oligosaccharides which possess an alditol function and a carboxylic acid group have been characterized
3

Minaya, Ramirez Enrique. "Un nouveau piège à ions circulaire pour la spectrométrie de masse et la structure nucléaire." Phd thesis, Université Paris Sud - Paris XI, 2009. http://tel.archives-ouvertes.fr/tel-00421111.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
La détermination de la masse nucléaire permet d'accéder à l'énergie de liaison donc au bilan de toutes les forces agissant dans le noyau. L'exploration de la structure nucléaire requiert la mesure des masses loin de la stabilité. Néanmoins la production des ions radioactifs est peu sélective et l'ion d'intérêt est souvent noyé dans un fond de contaminants isobariques. Ces dernières années, l'utilisation des pièges à ions linéaires et du refroidissement par gaz tampon a été fortement développée permettant la mesure de masse des noyaux exotiques avec une grande précision. Cette thèse porte sur le développement innovant d'un piège de Paul circulaire, "le cirque d'ions". Sa géométrie lui permet de confiner les ions sur un grand nombre de tours. Ainsi, ils peuvent être refroidis avec une pression de gaz tampon de l'ordre de 10-4 mbar. Par ailleurs, il est capable de trier en masse les ions piégés et refroidis avec un pouvoir de résolution suffisant pour séparer des isobares. Nous avons réalisé et testé le premier prototype de ce spectromètre à Orsay. Cette thèse étudie également les prédictions des masses par les différents modèles théoriques, en les comparant avec l'approche microscopique HFB-17. Actuellement, la masse des noyaux très exotiques peut seulement être prédite. L'étude de l'énergie de séparation de deux neutrons avec HFB-17 met en évidence des zones d'instabilité numérique. Afin de l'améliorer, nous avons apporté une correction aux énergies de déformation calculées par ce modèle, en utilisant comme référence les masses des chaînes isotopiques 143-146Xe et 223-229Rn que nous avons mesurées avec le spectromètre ISOLTRAP au CERN.
4

Becker, Joël. "Étude et développement d'un spectromètre de masse et énergie : modélisation et optimisation de l'optique, réalisation du prototype." Phd thesis, Université Pierre et Marie Curie - Paris VI, 2013. http://tel.archives-ouvertes.fr/tel-00905315.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
L'objectif de mon travail a été de développer, réaliser et tester un spectromètre de masse neutre afin d'étudier les exosphères planétaires : NIMEIS (Neutral and Ion Mass and Energy Imaging Spectrometer). Les particules présentes dans les exosphères planétaires peuvent s'interpréter comme la signature des processus d'interaction entre l'environnement des objets planétaires et leur atmosphère et/ou surface. Un instrument de mesure, capable de déterminer la masse et l'énergie des particules de l'exosphère a été imaginé afin d'identifier et caractériser ces processus. Un modèle numérique d'un spectromètre de masse et d'énergie pour la mesure des neutres et ions exosphériques a été développé afin de répondre aux objectifs instrumentaux imposés par notre connaissance de ces processus. A partir du modèle numérique obtenu, un prototype a été réalisé et des tests ont été effectués. En parallèle, j'ai travaillé sur le développement d'une source d'ionisation, également nécessaire pour le fonctionnement optimal du spectromètre de masse neutre, basée sur l'utilisation de nanotubes de carbone comme émetteurs d'électrons. Nous travaillons en collaboration avec un laboratoire Sud Coréen qui produit les nanotubes de carbone. Mon travail a permis de définir, concevoir et modéliser différents types de dispositifs pour parfaire l'extraction des électrons. J'ai également travaillé sur la définition et l'optimisation du modèle numérique de l'optique de l'instrument PICAM (Planetary Ion CAMera). PICAM est un spectromètre de masse d'ions de la mission Bepi-Colombo ayant pour objectif d'étudier l'exosphère ionisée de Mercure. La particularité de cet instrument est de mesurer la masse, l'énergie et de produire une image instantanée d'un champ de vue hémisphérique. L'optimisation du modèle s'est faite à partir d'un modèle numérique en partant du design de l'instrument DION de la mission Phobos-Grunt (Vaisberg et al. 2010). L'objectif de cette optimisation a consisté en la recherche d'une augmentation du facteur géométrique, indispensable dans le cadre de l'exploration de Mercure.
5

Bayat, Parisa. "Spectrométrie de masse en tandem pour l'étude des énergies de liaison de complexes "hôte-invité" et l'élucidation structurale d'oligosaccharides." Thesis, Sorbonne université, 2018. http://www.theses.fr/2018SORUS108.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
En faisant progresser la chimie hôte-invité (H-G), des efforts importants ont été déployés pour synthétiser des molécules hôtes avec des caractéristiques de reconnaissance moléculaire spécifiques et bien définies, y compris de sélectivité et d’affinité ajustable. Une étape importante dans le processus est la caractérisation des forces de liaison des complexes H-G. Cette caractérisation est typiquement réalisée en solution en utilisant la RMN ou la fluorescence. L'étude en phase gazeuse de l'énergétique des systèmes H-G est très importante pour fournir des informations concernant leurs propriétés intrinsèques de liaison. La majeure partie de cette thèse est consacrée à l'étude de l'énergétique des complexes H-G formés par trois hôtes en cage d'hémicryptophane avec diverses molécules invitées biologiquement pertinentes. Parmi les techniques basées sur la spectrométrie de masse en tandem, nous utilisons ici la dissociation radiative infrarouge de corps noir (BIRD), la dissociation induite par collision basse énergie (CID à basse énergie), la dissociation de collision de plus haute énergie (HCD) et la CID haute pression pour les mesures énergétiques des complexes HG. Ces techniques ont été utilisées soit seules, soit en combinaison les unes avec les autres, soit avec la modélisation Rice-Ramsperger-Kassel-Marcus (RRKM). Ce travail nous a permis de développer la CID à basse énergie, technique prometteuse mais jusqu’à présent peu employée
In advancing host-guest (H-G) chemistry, considerable effort has been spent to synthesize host molecules with specific and well-defined molecular recognition characteristics including selectivity and adjustable affinity. An important step in the process is the characterization of binding strengths of the H-G complexes. This characterization is typically performed in solution using NMR or fluorescence. Gas-phase investigation of energetics of H-G systems is of great importance in providing information regarding their intrinsic binding properties. The major portion of this thesis is devoted to the study of the energetics of H-G complexes formed by three hemicryptophane cage hosts with various biologically-relevant guest molecules. Among the existing tandem mass spectrometry-based techniques, here we employ blackbody infrared radiative dissociation (BIRD), low-energy collision induced dissociation (low-energy CID), higher-energy collision dissociation (HCD) and high-pressure CID for measurements of energetics of H-G complexes. These techniques were used either alone, or in combination with each other, or with Rice–Ramsperger–Kassel–Marcus (RRKM) modeling. This work has allowed us to develop the low-energy CID, a promising technique, but so far infrequently used
6

Claverie, Fanny. "Développement et applications d’un système laser femtoseconde infra-rouge basse énergie et haute cadence de tir pour l’analyse d’éléments trace dans les solides par couplage ablation laser / ICPMS." Pau, 2009. https://theses.hal.science/docs/00/40/14/50/PDF/These_Fanny_CLAVERIE.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
L’ablation laser couplée à une détection par spectrométrie de masse à plasma induit apparait de plus en plus comme un outil de choix pour l’analyse des solides. L’utilisation de sources laser femtoseconde permet d’améliorer les performances analytiques du couplage, l’interaction laser-matière privilégiant les phénomènes athermiques contrairement aux lasers nanoseconde plus classiquement utilisés. Une collaboration entre le Laboratoire de Chimie Analytique Bio-Inorganique et Environnement de Pau et Novalase SA (spécialisé dans l’intégration optique et laser) a fait naitre la première station d’ablation laser femtoseconde intégrée. Ses caractéristiques particulières, que sont la haute cadence de tir et un optique de balayage rapide du faisceau, permettent d’explorer de nouvelles stratégies d’ablation et ouvrent des perspectives analytiques encourageantes en terme de sensibilité et de mode de quantification. Le potentiel de ce prototype a été évalué au travers d’analyses fondamentales, telles que le fractionnement élémentaire et l’étude de la taille des particules de l’aérosol produit par ablation, et de différentes applications telles que l’analyse de sols et de sédiments par dilution isotopique réalisée par le laser dans la chambre d’ablation, la détection de sélénoprotéines dans des gels d’électrophorèse et la détermination de l’isotopie de l’uranium dans des particules micrométriques
Laser ablation inductively coupled plasma mass spectrometry is more and more considered as a tool of choice for solid analysis. The use of femtosecond laser sources permit to improve analytical performances of the coupling thanks to the non-thermal ablation obtained in comparison with the more conventional nanosecond laser used. Through a collaboration between the LCABIE (Laboratoire de Chimie Analytique Bio-Inorganique et Environnement) of Pau and Novalase SA (a company specialized in optical and laser integration), the first integrated femtosecond laser ablation system was designed in 2003. Its unusual characteristics (high repetition rate and scanning beam device) allow to perform some new ablation strategies and open encouraging analytical perspectives in terms of sensitivity and quantification. The potential of this prototype was evaluated through fundamental analyses such as elemental fractionation and characterization of the aerosol produced by laser ablation and through the development of different applications such as analysis of soils and sediments by in-cell isotope dilution, detection of selenoproteins in gel electrophoresis, and determination of uranium isotopic composition of micrometric particles
7

Yazidjian, Chabouh. "Conception d'un système de détection pour ISOLTRAP et test de l'équation de masse aux multiplets isobariques." Caen, 2006. http://www.theses.fr/2006CAEN2082.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Situé auprès du séparateur isotopique en ligne ISOLDE du CERN, le spectromètre de masse ISOLTRAP, composé de pièges de Penning, est spécialement conçu pour une spectrométrie de masse de haute précision tout particulièrement pour les isotopes radioactifs de courte durée de vie. Reposant sur la mesure de la fréquence cyclotron d'un ion piégé dans une cavité supraconductrice où règne un fort champ magnétique, la précision relative sur la masse atteinte par cette installation est de 10-8 avec un pouvoir de résolution pour les ions contaminants de R=107. Ces mesures réalisées pour des noyaux instables particuliers sont primordiales puisqu'elles servent de test draconien des modèles nucléaires. Le point principal de ce mémoire est la conception, l'installation et la caractérisation d'un nouveau détecteur Channeltron afin d'augmenter l'efficacité de détection d'\ISOLTRAP d'un facteur proche de 3. Une efficacité de detection proche de 100 pourcent étant atteinte, il est désormais possible de manipuler un seul et unique ion mais aussi d'atteindre des noyaux exotiques encore plus éloignés de la vallée de stabilité et qui ont une durée de vie d'autant plus brève. Concernant la spectrométrie de noyaux à courte durée de vie, la masse des isotopes du potassium 35K (178ms) au 46K (105s) a été déterminée avec une incertitude realtive inférieure à 1. 6 10-8. Cette jutesse sur la masse du 35K a contribué au test de l'équation de masse du multiplet isobarique pour le quartet de masse A=35 et d'isospin T=3/2
Installed at the on-line isotope separator ISOLDE at CERN, the tandem Penning-trap spectrometer ISOLTRAP is designed to perform high-accuracy mass measurements on short-lived radionuclides. Based on the determination of the ion cyclotron frequency in a strong magnetic field, the typical relative mass uncertainty is 10-8 with a resolving power of up to R=107. Accurate and precise mass values for specific unstable nuclides are important since they serve e. G. As a stringent test of nuclear models. The main part of this work is the design, installation and characterization of a new Channeltron-detector setup in order to increase the detection efficiency of ISOLTRAP by about a factor of 3. Since a detection efficiency close to 100 percent is reached, true single-ion experiments can be performed for the first time and exotic nuclides further away from the valley of stability and with very short half-lives are now accessible. Concerning mass measurements on short-lived nuclides, the masses of potassium isotopes from 35K (178ms) up to 6K (105s) have been measured with a relative precision of better than 1. 6 10-8. The accurate value of the 35K mass contributes to a stringent test of the isobaric multiplet mass equation for the A=35, T=3/2 isospin quartet
8

Bail, Adeline. "Mesures de rendements isobariques et isotopiques des produits de fission lourds sur le spectromètre de masse LOHENGRIN." Phd thesis, Université Sciences et Technologies - Bordeaux I, 2009. http://tel.archives-ouvertes.fr/tel-00410261.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Les rendements de fission sont des données très importantes pour les applications nucléaires. Elles représentent par exemple une partie des données d'entrée des différents codes de simulation. De même les modèles théoriques qui tentent de reproduire ces distributions ont besoin de valeurs expérimentales auxquelles ils peuvent se comparer. Par le passé le spectromètre de masse Lohengrin a permis, grâce à sa très bonne résolution en masse et en énergie, de déterminer avec une grande précision les rendements des produits de fission légers pour de nombreux systèmes fissionants. Cependant la méthode expérimentale utilisée dans cette région de la fission, détection par chambre à ionisation, ne permet pas la séparation des isotopes dans la région des produits de fission lourds. Pour cette raison un nouveau dispositif expérimental par spectrométrie a été mis en place au cours de cette thèse. Il a été validé par comparaison des précédentes mesures dans la région des produits de fission légers et permet de déterminer les rendements isotopiques que ce soit pour les produits de fission légers comme pour les produits de fission lourds. Ainsi au cours de ces travaux, afin de compléter et d'améliorer les bibliothèques de donn ées, les rendements en masse des produits de fission lourds pour les réactions 235U(nth,f), 239Pu(nth,f) et 241Pu(nth,f) ont été mesurés pour la première fois sur le spectromètre Lohengrin. Ils ont permis d'améliorer considérablement les incertitudes associées. De la même manière les rendements isotopiques des produits de fission lourds pour le 239Pu(nth,f) ont été déterminés par spectrométrie . De plus les distributions en charge ionique et en énergie cinétique des produits de fission ont été particulièrement étudiées. Elles ont entre autres mis en évidence la présence d'isomères nanosecondes pour certains noyaux.
9

Nguyen, Duy Luan. "Catalyseurs à base d'or pour la réduction catalytique sélective des oxydes d'azote par les hydrocarbures provenant de sources mobiles." Thesis, Lille 1, 2012. http://www.theses.fr/2012LIL10133/document.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Les émissions de gaz toxiques provenant de sources mobiles, tels que les oxydes d’azote (NOx) sont aujourd’hui soumises à réglementation celles-ci devenant de plus en plus strictes notamment dans le cadre de la norme Euro 6 qui sera en vigueur à l’échelle européenne à partir de 2014. Dans le cas de véhicules Diesel, de nombreux verrous scientifiques subsistent notamment pour éliminer simultanément les suies et les NOx en milieu globalement oxydant. Ce travail est consacré à la conversion sélective des NOx en N2 dans des compositions de mélanges gazeux représentatives des effluents gazeux en sortie de moteurs Diesel. Parmi les technologies envisagées, la réduction sélective des NOx en N2 par les hydrocarbures se singularise par sa simplicité à mettre en œuvre. De nouvelles familles de catalyseurs à base d’or dispersé sur l’alumine ont été mises en œuvre en remplacement du platine et palladium. L’étude de leur stabilité en milieu réactionnel à 500°C a permis de sélectionner différente méthodes de préparation par dépôt-précipitation (DP) et par échange ionique (AE). Typiquement, cette dernière méthode de préparation conduit à un domaine de conversion beaucoup plus étendu notamment après vieillissement à 500°C. Par ailleurs, la réduction des NOx est sensible aux tailles des particules les plus grosses semblant plus actives que les plus petites thermodynamiquement plus instables. Dans le contexte du post-traitement, où une recristallisation est souvent observée à haute température, ce dernier paramètre confère aux catalyseurs Au/Al2O3 un certain attrait pour un développement ultérieur. La seconde partie est consacré à la modification des catalyseurs Au/Al2O3 par ajout d’argent. Les méthodes co-précipitation et greffage montrent que les particules bimétalliques obtenues après activation thermique sous hydrogène sont peu actives. L’or et l’argent métalliques en interaction voient leurs propriétés électroniques perturbées ce qui a pour conséquence d’orienter la sélectivité en faveur des réactions d’oxydation des réducteurs par l’oxygène présent en grand excès. En revanche, l’imprégnation successive permet d’obtenir un gain substantiel en conversion des NOx lorsque Au et Ag préservent leur propriétés intrinsèques. Différents paramètres opératoires ont été examinés montrant l’intérêt de déposer Ag avant Au de façon à maintenir en surface un rapport atomique Au/Ag optimal
Nowadays, emissions of atmospheric pollutants from mobile sources such as nitric oxides (NOx) are submitted to more stringent regulations especially within the next Euro 6 which will be implemented in Europe at the beginning of 2014. Up to now commercialized technologies available for the abatement of NOx from lean burn engine (running with a large excess of oxygen) are not capable to remove simultaneously NOx and particulates in lean atmosphere. This study is essentially focused on the NOx conversion to nitrogen via the Selective Catalytic Reduction by using hydrocarbons (HC-SCR) in representative Diesel exhaust gas conditions. This technology is more feasible than the Lean-NOx trap and Urea-SCR systems. Supported gold catalysts on alumina have been developped for the replacement of Pt and Pd less selective. Particular attention was paid to the thermal stability under reaction conditions at 500°C. Among the different synthesis protocols investigated (Deposition-precipitation, Anionic exchange), it was found that the anionic exchange method leads to the best compromise with a larger operating window after ageing. In addition, the reduction of NOx to nitrogen seems structure sensitive, the largest particles being more active than the smallest ones usually thermodynamically instable at high temperature. In this context, such behavior should be profitably used for further practical developments since post-combustion catalysts essentially run at rather high temperature. The second part of this study was dedicated to the modification of Au/Al2O3 catalysts after silver incorporation. Different strategies implemented for Ag incorporation have been examined. Coprecipitation and grafting lead to the formation of bimetallic particles with homogeneous distribution of gold and silver especially via the coprecipitation method. Strong interaction between Au and Ag with further modification of their electronic and adsorptive properties leads to strong deactivation. On the other hand, the segregation of both metals on alumina preserving their intrinsic properties improves the catalytic performances especially after ageing. The influence of different operating condition has been examined showing the best compromise when gold is successively impregnated on Ag/Al2O3
10

Kennel, Claire. "Mesures expérimentales et modélisation de la formation des oxydes d'azote dans les flammes d'hydrocarbures dopées à l'amoniac." Rouen, 1989. http://www.theses.fr/1989ROUES001.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Mesures de profils de concentration des principales espèces stables et radicalaires dans les flammes CH4/O2/NH3 et CO/O2/H2NH3 par spectrométrie de masse. Comparaison avec des profils de concentration calculés à l'aide d'un programme numérique à partir d'un schéma cinétique complet. Proposition d'un modèle cinétique

Books on the topic "Spectrométrie en énergie et de masse":

1

Constantin, Emilia. Spectrométrie de masse: Principes et applications. Paris: Technique et documentation-Lavoisier, 1986.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Caudell, Thomas. Practical Supercritical Fluid Chromatography and Extraction. CRC Press LLC, 2018.

Find full text
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Spectrométrie en énergie et de masse":

1

"4 Masse et énergie." In Les relativités : Espace, Temps, Gravitation, 53–66. EDP Sciences, 2020. http://dx.doi.org/10.1051/978-2-7598-1815-0-006.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

"4 Masse et énergie." In Les relativités : Espace, Temps, Gravitation, 53–66. EDP Sciences, 2020. http://dx.doi.org/10.1051/978-2-7598-1815-0.c006.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Gratuze, Bernard. "Application de la spectrométrie de masse à plasma." In Circulation et provenance des matériaux dans les sociétés anciennes, 243–72. Editions des archives contemporaines, 2014. http://dx.doi.org/10.17184/eac.4101.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

"V Représentations des groupes de Galilée et de Poincaré : masse, spin et énergie." In Symétries continues, 139–220. EDP Sciences, 2021. http://dx.doi.org/10.1051/978-2-7598-2632-2.c007.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

COLLIN-ZAHN, Suzy. "Les noyaux actifs de galaxies : un combat entre accrétion et éjection." In Noyaux actifs de galaxie, 1–65. ISTE Group, 2023. http://dx.doi.org/10.51926/iste.9087.ch1.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Depuis la découverte des premiers « noyaux actifs de galaxie » en 1943, notre compréhension de ces objets a beaucoup évolué. Leur énergie provient de l’accrétion de gaz par un trou noir super-massif. La diversité apparente des noyaux actifs est due essentiellement à l’inclinaison de leur axe de rotation. La masse des trous noirs est proportionnelle à celle des bulbes des galaxies-hôtes. Les jets relativistes et les différents modes d’accrétion sont liés au spin du trou noir.
6

"Unités de longueur, de temps et de masse-énergie avec les ordres de grandeurs correspondants." In L'aventure du grand collisionneur LHC, 303–4. EDP Sciences, 2020. http://dx.doi.org/10.1051/978-2-7598-1226-4-018.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

"Unités de longueur, de temps et de masse-énergie avec les ordres de grandeurs correspondants." In L'aventure du grand collisionneur LHC, 303–4. EDP Sciences, 2020. http://dx.doi.org/10.1051/978-2-7598-1226-4.c018.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Spectrométrie en énergie et de masse":

1

Gueddari, K., M. R. LaFlèche, and J. Amossé. Extraction chimique des éléments du groupe du platine et de l'or et détermination de leurs teneurs par spectrométrie de masse à émission de plasma. Natural Resources Canada/ESS/Scientific and Technical Publishing Services, 1998. http://dx.doi.org/10.4095/209534.

Full text
APA, Harvard, Vancouver, ISO, and other styles

To the bibliography