Journal articles on the topic 'Respiratory Inductive Plethysmography (RIP)'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 journal articles for your research on the topic 'Respiratory Inductive Plethysmography (RIP).'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.
Hargrove, Jeff, Eric D. Zemper, and Mary L. Jannausch. "Respiratory Measurement Utilizing a Novel Laser Displacement Technique: Normal Tidal Breathing." Biomedical Instrumentation & Technology 43, no. 4 (July 1, 2009): 327–31. http://dx.doi.org/10.2345/0899-8205-43.4.327.
Full textRevow, M. D., S. J. England, H. A. Stogryn, and D. L. Wilkes. "Comparison of calibration methods for respiratory inductive plethysmography in infants." Journal of Applied Physiology 63, no. 5 (November 1, 1987): 1853–61. http://dx.doi.org/10.1152/jappl.1987.63.5.1853.
Full textWeber, Kaye, Sherry E. Courtney, Kee H. Pyon, Gordon Y. Chang, Paresh B. Pandit, and Robert H. Habib. "Detecting lung overdistention in newborns treated with high-frequency oscillatory ventilation." Journal of Applied Physiology 89, no. 1 (July 1, 2000): 364–72. http://dx.doi.org/10.1152/jappl.2000.89.1.364.
Full textSackner, M. A., H. Watson, A. S. Belsito, D. Feinerman, M. Suarez, G. Gonzalez, F. Bizousky, and B. Krieger. "Calibration of respiratory inductive plethysmograph during natural breathing." Journal of Applied Physiology 66, no. 1 (January 1, 1989): 410–20. http://dx.doi.org/10.1152/jappl.1989.66.1.410.
Full textWhyte, K. F., M. Gugger, G. A. Gould, J. Molloy, P. K. Wraith, and N. J. Douglas. "Accuracy of respiratory inductive plethysmograph in measuring tidal volume during sleep." Journal of Applied Physiology 71, no. 5 (November 1, 1991): 1866–71. http://dx.doi.org/10.1152/jappl.1991.71.5.1866.
Full textAbdulhay, Enas, Pierre-Yves Gumery, R. Ilango, S. Hariharasitaraman, M. Thilagaraj, N. Arunkumar, and Gustavo Ramirez-Gonzalez. "Stroke Volume Estimation from Respiratory Inductive Plethysmography: Double Empirical Decomposition." Scientific Programming 2022 (January 31, 2022): 1–15. http://dx.doi.org/10.1155/2022/9942367.
Full textTobin, M. J., S. M. Guenther, W. Perez, and M. J. Mador. "Accuracy of the respiratory inductive plethysmograph during loaded breathing." Journal of Applied Physiology 62, no. 2 (February 1, 1987): 497–505. http://dx.doi.org/10.1152/jappl.1987.62.2.497.
Full textWatson, H. L., D. A. Poole, and M. A. Sackner. "Accuracy of respiratory inductive plethysmographic cross-sectional areas." Journal of Applied Physiology 65, no. 1 (July 1, 1988): 306–8. http://dx.doi.org/10.1152/jappl.1988.65.1.306.
Full textSeddon, Paul, Sonia Sobowiec-Kouman, and David Wertheim. "Infant home respiratory monitoring using pulse oximetry." Archives of Disease in Childhood 103, no. 6 (July 7, 2016): 603–5. http://dx.doi.org/10.1136/archdischild-2016-310712.
Full textFontecave-Jallon, Julie, Pierre-Yves Guméry, Pascale Calabrese, Raphaël Briot, and Pierre Baconnier. "A Wearable Technology Revisited for Cardio-Respiratory Functional Exploration." International Journal of E-Health and Medical Communications 4, no. 1 (January 2013): 12–22. http://dx.doi.org/10.4018/jehmc.2013010102.
Full textRetory, Yann, Pauline Niedzialkowski, Carole de Picciotto, Marcel Bonay, and Michel Petitjean. "New Respiratory Inductive Plethysmography (RIP) Method for Evaluating Ventilatory Adaptation during Mild Physical Activities." PLOS ONE 11, no. 3 (March 23, 2016): e0151983. http://dx.doi.org/10.1371/journal.pone.0151983.
Full textTang, Hai-Ming, Carrie Laduke, Dave Reynolds, Cynthia Carey, Suzette Hahn, and Gregory S. Friedrichs. "Respiratory Rates Derived From Arterial Blood Pressure Waveforms in Telemetered Dogs." International Journal of Toxicology 39, no. 6 (August 13, 2020): 542–46. http://dx.doi.org/10.1177/1091581820946703.
Full textSartene, R., P. Martinot-Lagarde, M. Mathieu, A. Vincent, M. Goldman, and G. Durand. "Respiratory cross-sectional area-flux measurements of the human chest wall." Journal of Applied Physiology 68, no. 4 (April 1, 1990): 1605–14. http://dx.doi.org/10.1152/jappl.1990.68.4.1605.
Full textMiller, Carrie, Andrew M. Hoffman, and Janice Hunter. "Thoracoabdominal asynchrony failed to grade airway obstructions in foals." Journal of Applied Physiology 88, no. 6 (June 1, 2000): 2081–87. http://dx.doi.org/10.1152/jappl.2000.88.6.2081.
Full textTana, M., C. Tirone, C. Aurilia, A. Lio, C. Ricci, S. Perelli, C. Romagnoli, and G. Vento. "A23 Changes in lung volume measured by respiratory inductive plethysmography (RIP) during recruitment HFOV procedure in preterm infants." Early Human Development 88 (May 2012): S108. http://dx.doi.org/10.1016/s0378-3782(12)70049-x.
Full textSchüler, Willi, Nicolai Spicher, and Thomas M. Deserno. "Cardiopulmonary coupling analysis using smart wearables and mobile computing." Current Directions in Biomedical Engineering 7, no. 2 (October 1, 2021): 291–94. http://dx.doi.org/10.1515/cdbme-2021-2074.
Full textVento, Giovanni, Milena Tana, Chiara Tirone, Claudia Aurilia, Alessandra Lio, Sarah Perelli, Cinzia Ricci, and Costantino Romagnoli. "Unexpected effect of recruitment procedure on lung volume measured by respiratory inductive plethysmography (RIP) during high frequency oscillatory ventilation (HFOV) in preterm neonates with respiratory distress syndrome (RDS)." Journal of Maternal-Fetal & Neonatal Medicine 24, sup1 (September 2, 2011): 159–62. http://dx.doi.org/10.3109/14767058.2011.607587.
Full textVerschakelen, J. A., K. Deschepper, and M. Demedts. "Relationship between axial motion and volume displacement of the diaphragm during VC maneuvers." Journal of Applied Physiology 72, no. 4 (April 1, 1992): 1536–40. http://dx.doi.org/10.1152/jappl.1992.72.4.1536.
Full textDall'ava-Santucci, J., A. Armaganidis, F. Brunet, J. F. Dhainaut, S. Nouira, D. Morisseau, and A. Lockhart. "Mechanical effects of PEEP in patients with adult respiratory distress syndrome." Journal of Applied Physiology 68, no. 3 (March 1, 1990): 843–48. http://dx.doi.org/10.1152/jappl.1990.68.3.843.
Full textTobin, M. J., W. Perez, S. M. Guenther, R. F. Lodato, and D. R. Dantzker. "Does rib cage-abdominal paradox signify respiratory muscle fatigue?" Journal of Applied Physiology 63, no. 2 (August 1, 1987): 851–60. http://dx.doi.org/10.1152/jappl.1987.63.2.851.
Full textSá, Rui Carlos, G. Kim Prisk, and Manuel Paiva. "Microgravity alters respiratory abdominal and rib cage motion during sleep." Journal of Applied Physiology 107, no. 5 (November 2009): 1406–12. http://dx.doi.org/10.1152/japplphysiol.91516.2008.
Full textTomich, Georgia Miranda, Danielle Corrêa França, Marco Túlio Costa Diniz, Raquel Rodrigues Britto, Rosana Ferreira Sampaio, and Verônica Franco Parreira. "Effects of breathing exercises on breathing pattern and thoracoabdominal motion after gastroplasty." Jornal Brasileiro de Pneumologia 36, no. 2 (April 2010): 197–204. http://dx.doi.org/10.1590/s1806-37132010000200007.
Full textGagliardi, Luigi, Franca Rusconi, Hazel Aston, and Michael Silverman. "Occlusion maneuver to detect the relative contribution of the rib cage and abdomen to tidal volume using respiratory inductive plethysmography in infants." Pediatric Pulmonology 21, no. 2 (February 1996): 132–37. http://dx.doi.org/10.1002/(sici)1099-0496(199602)21:2<132::aid-ppul8>3.0.co;2-t.
Full textDarling-White, Meghan. "Comparison of Respiratory Calibration Methods for the Estimation of Lung Volume in Children With and Without Neuromotor Disorders." Journal of Speech, Language, and Hearing Research 65, no. 2 (February 9, 2022): 525–37. http://dx.doi.org/10.1044/2021_jslhr-21-00333.
Full textChapman, K. R., A. Perl, N. Zamel, and A. S. Rebuck. "Thoracoabdominal motion during hypercapnia, hypoxia, and exercise." Canadian Journal of Physiology and Pharmacology 63, no. 3 (March 1, 1985): 188–92. http://dx.doi.org/10.1139/y85-035.
Full textRussell, Nancy K., and Elaine Stathopoulos. "Lung Volume Changes in Children and Adults during Speech Production." Journal of Speech, Language, and Hearing Research 31, no. 2 (June 1988): 146–55. http://dx.doi.org/10.1044/jshr.3102.146.
Full textIzumizaki, Masahiko, Michiko Iwase, Yasuyoshi Ohshima, and Ikuo Homma. "Acute effects of thixotropy conditioning of inspiratory muscles on end-expiratory chest wall and lung volumes in normal humans." Journal of Applied Physiology 101, no. 1 (July 2006): 298–306. http://dx.doi.org/10.1152/japplphysiol.01598.2005.
Full textClarysse, I., and M. Demedts. "Human esophageal pressures and chest wall configuration in upright and head-down posture." Journal of Applied Physiology 59, no. 2 (August 1, 1985): 401–7. http://dx.doi.org/10.1152/jappl.1985.59.2.401.
Full textTatulli, Eric, Julie Fontecave-Jallon, Pascale Calabrese, and Pierre-Yves Gumery. "Respiratory Inductance Plethysmography for Automated Swallowing Detection." International Journal of E-Health and Medical Communications 11, no. 2 (April 2020): 64–77. http://dx.doi.org/10.4018/ijehmc.2020040104.
Full textCarry, Pierre-Yves, Pierre Baconnier, Andre Eberhard, Pierre Cotte, and Gila Benchetrit. "Evaluation of Respiratory Inductive Plethysmography." Chest 111, no. 4 (April 1997): 910–15. http://dx.doi.org/10.1378/chest.111.4.910.
Full textStromberg, N. O., G. O. Dahlback, and P. M. Gustafsson. "Evaluation of various models for respiratory inductance plethysmography calibration." Journal of Applied Physiology 74, no. 3 (March 1, 1993): 1206–11. http://dx.doi.org/10.1152/jappl.1993.74.3.1206.
Full textSilva, Luís, Mariana Dias, Duarte Folgado, Maria Nunes, Praneeth Namburi, Brian Anthony, Diogo Carvalho, Miguel Carvalho, Elazer Edelman, and Hugo Gamboa. "Respiratory Inductance Plethysmography to Assess Fatigability during Repetitive Work." Sensors 22, no. 11 (June 2, 2022): 4247. http://dx.doi.org/10.3390/s22114247.
Full textHoffman, Andrew, Heike Kuehn, Klaus Riedelberger, Rachel Kupcinskas, and Mary Beth Miskovic. "Flowmetric comparison of respiratory inductance plethysmography and pneumotachography in horses." Journal of Applied Physiology 91, no. 6 (December 1, 2001): 2767–75. http://dx.doi.org/10.1152/jappl.2001.91.6.2767.
Full textSelbie, R. D., M. Fletcher, N. Arestis, R. White, A. Duncan, P. Helms, and P. Duffty. "Respiratory function parameters in infants using inductive plethysmography." Medical Engineering & Physics 19, no. 6 (September 1997): 501–11. http://dx.doi.org/10.1016/s1350-4533(97)00024-6.
Full textWarren, Robert Hughes, and Sheila Horan Alderson. "Breathing Patterns in Infants Utilizing Respiratory Inductive Plethysmography." Chest 89, no. 5 (May 1986): 717–22. http://dx.doi.org/10.1378/chest.89.5.717.
Full textNeumann, Peter, Jörg Zinserling, Christian Haase, Michael Sydow, and Hilmar Burchardi. "Evaluation of Respiratory Inductive Plethysmography in Controlled Ventilation." Chest 113, no. 2 (February 1998): 443–51. http://dx.doi.org/10.1378/chest.113.2.443.
Full textStrang, Abigail, Lauren Ryan, Tariq Rahman, Sona Balasubramanian, Jobayer Hossain, Robert Heinle, and Thomas H. Shaffer. "Measures of respiratory inductance plethysmography (RIP) in children with neuromuscular disease." Pediatric Pulmonology 53, no. 9 (July 12, 2018): 1260–68. http://dx.doi.org/10.1002/ppul.24134.
Full textFiamma, Marie-Noëlle, Ziyad Samara, Pierre Baconnier, Thomas Similowski, and Christian Straus. "Respiratory inductive plethysmography to assess respiratory variability and complexity in humans." Respiratory Physiology & Neurobiology 156, no. 2 (May 2007): 234–39. http://dx.doi.org/10.1016/j.resp.2006.12.001.
Full textHODOUS, THOMAS K., JOHN L. HANKINSON, and GREGORY P. STARK. "Workplace Measurement of Respirator Effects Using Respiratory Inductive Plethysmography." American Industrial Hygiene Association Journal 50, no. 7 (July 1989): 372–78. http://dx.doi.org/10.1080/15298668991374822.
Full textMusante, Gabriel, Nelson Claure, Tilo Gerhardt, Ruth Everett, and Eduardo Bancalari. "Evaluation of Respiratory Inductive Plethysmography in VLBW infants 1709." Pediatric Research 43 (April 1998): 291. http://dx.doi.org/10.1203/00006450-199804001-01731.
Full textBrazelton, Thomas B., Kenneth F. Watson, John E. Thompson, and John H. Arnold. "Respiratory Inductive Plethysmography Is Stable during High Frequency Ventilation." Pediatric Research 45, no. 4, Part 2 of 2 (April 1999): 38A. http://dx.doi.org/10.1203/00006450-199904020-00228.
Full textAdams, Jose A., Ignacio A. Zabaleta, David Stroh, Paulette Johnson, and Marvin A. Sackner. "Tidal Volume Measurements in Newborns Using Respiratory Inductive Plethysmography." American Review of Respiratory Disease 148, no. 3 (September 1993): 585–88. http://dx.doi.org/10.1164/ajrccm/148.3.585.
Full textWerchowski, J. L., M. H. Sanders, J. P. Costantino, F. C. Sciurba, and R. M. Rogers. "Inductance plethysmography measurement of CPAP-induced changes in end-expiratory lung volume." Journal of Applied Physiology 68, no. 4 (April 1, 1990): 1732–38. http://dx.doi.org/10.1152/jappl.1990.68.4.1732.
Full textHollier, Carly A., Alison R. Harmer, Lyndal J. Maxwell, Collette Menadue, Grant N. Willson, Deborah A. Black, and Amanda J. Piper. "Validation of respiratory inductive plethysmography (LifeShirt) in obesity hypoventilation syndrome." Respiratory Physiology & Neurobiology 194 (April 2014): 15–22. http://dx.doi.org/10.1016/j.resp.2014.01.014.
Full textMarkhorst, Dick G., and Huibert R. van Genderingen. "Accuracy of Respiratory Inductive Plethysmography in Estimating Lung Volume Changes." Critical Care Medicine 32, no. 5 (May 2004): 1241–42. http://dx.doi.org/10.1097/01.ccm.0000124858.73354.ec.
Full textDe Groote, Anne, Manuel Paiva, and Yves Verbandt. "Mathematical assessment of qualitative diagnostic calibration for respiratory inductive plethysmography." Journal of Applied Physiology 90, no. 3 (March 1, 2001): 1025–30. http://dx.doi.org/10.1152/jappl.2001.90.3.1025.
Full textWarren, Robert Hughes, and Sheila Horan Alderson. "Calibration of Computer-Assisted (Respicomp) Respiratory Inductive Plethysmography in Newborns." American Review of Respiratory Disease 131, no. 4 (April 1985): 564–67. http://dx.doi.org/10.1164/arrd.1985.131.4.564.
Full textWarren, R. H., S. M. Horan, and P. K. Robertson. "Chest wall motion in preterm infants using respiratory inductive plethysmography." European Respiratory Journal 10, no. 10 (October 1, 1997): 2295–300. http://dx.doi.org/10.1183/09031936.97.10102295.
Full textMillard, R. K. "Key to better qualitative diagnostic calibrations in respiratory inductive plethysmography." Physiological Measurement 23, no. 2 (March 14, 2002): N1—N8. http://dx.doi.org/10.1088/0967-3334/23/2/401.
Full textBanovcin, Peter, Yvone Gusewell, and Horst Von Der Hardt. "262 MEASUREHSNT OF BRONCHIAL OBSTRUCTION BY RESPIRATORY INDUCTANCE PLETHYSMOGRAPHY (RIP) IN SCHOOL CHILDREN." Pediatric Research 36, no. 1 (July 1994): 46A. http://dx.doi.org/10.1203/00006450-199407000-00262.
Full text