Dissertations / Theses on the topic 'Radiosurgery'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Radiosurgery.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Yun, Michael Jino. "Radiosurgery for Malignant Brain Tumors." VCU Scholars Compass, 1994. http://scholarscompass.vcu.edu/etd/5088.
Full textDubé, Frédéric. "Spiral irradiation in stereotactic radiosurgery." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1999. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape9/PQDD_0016/MQ55049.pdf.
Full textDubé, Frédéric 1973. "Spiral irradiation in stereotactic radiosurgery." Thesis, McGill University, 1999. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=29884.
Full textA study of the beam distribution characteristics for the clinical linac-based radiosurgical techniques is presented. Two spiral linac-based radiosurgical techniques are developed: the uniform dose-rate spiral irradiation and the dose-rate-weighted spiral irradiation. Both exhibit the same spiraling beam entry trace over the patient's head; however, they differ in their beam distribution along the spiral. The dose-rate-weighted spiral irradiation provides a uniform beam distribution over the 2pi solid angle available in radiosurgery.
The currently existing techniques and the spiral techniques are then compared using the cumulative dose-volume histogram (CDVH) tools available with the McGill Treatment Planning System (MPS). The dose-rate-weighted spiral technique leads to lower dose inhomogeneities within the target volume and better dose conformity within the target. Moreover, it also encompasses smaller volumes of tissue at all isodose levels with larger differences at low isodose levels. A conclusion is reached that the dose-rate-weighted spiral irradiation technique offers interesting advantages over the currently used clinical linac-based techniques.
Bourque, Daniel. "Static conformal fields in stereotactic radiosurgery." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1997. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp01/MQ37097.pdf.
Full textSchlaefer, Alexander. "Computer assisted planning for robotic radiosurgery." Berlin Logos-Verl, 2007. http://d-nb.info/988177684/04.
Full textHu, Xiaoliang. "A New Gamma Knife Radiosurgery Paradigm: Tomosurgery." online version, 2007. http://rave.ohiolink.edu/etdc/view?acc%5Fnum=case1170292131.
Full textChua, T. T. Daniel. "Stereotactic radiosurgery as salvage treatment for locally recurrent nasopharyngeal carcinoma." Click to view the E-thesis via HKUTO, 2006. http://sunzi.lib.hku.hk/hkuto/record/B37223513.
Full textOtto, Karl. "3-dimensional anatomy-based verification in stereotactic radiosurgery." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1997. http://www.collectionscanada.ca/obj/s4/f2/dsk2/tape16/PQDD_0014/MQ37154.pdf.
Full textAuld, Lindsay. "Treatment dose verification in stereotactic radiosurgery quality assurance." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1999. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape8/PQDD_0015/MQ45883.pdf.
Full textOtto, Karl 1972. "3-dimensional anatomy-based verification in stereotactic radiosurgery." Thesis, McGill University, 1997. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=27895.
Full textSixel, Katharina E. (Katharina Elisabeth). "Physical parameters of narrow photon beams in radiosurgery." Thesis, McGill University, 1990. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=59890.
Full textPhysical aspects of radiosurgery based on isocentric linear accelerators (linacs) are presented. The equipment and techniques used in the measurement of various radiosurgical beam parameters are discussed. Also discussed is the accuracy of radiation beam delivery to the target, the calculation and measurement of 3-dimensional isodose distributions obtained from circular beams, and the production of cylindrical dose distributions with rectangular beams. It is shown from the physics point-of-view that linac-based radiosurgery is a viable alternative to radiosurgery with the commercially available Gamma unit.
Oliveira, Silvana C. "Comparison of three linac-based stereotactic radiosurgery techniques." Thesis, McGill University, 2003. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=19455.
Full textNarayanan, Sridar 1966. "Image analysis for the assessment of stereotactic radiosurgery." Thesis, McGill University, 1994. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=68229.
Full textThe image-dose analysis software, running on a UNIX workstation, is presented, including software utilities for the evaluation of radiosurgery treatment plans based on magnetic resonance (MR) images. The importance of dose-volume histograms (DVHs) in the assessment of treatment plans is discussed, and the software developed to generate DVHs is described.
A technique for the experimental verification of calculated three-dimensional (3D) dose distributions is presented. This computerized approach is based on stereotactic principles and uses a plastic phantom and radiotherapy verification film as the dosimeter. The results indicate that, with some improvements, this is a viable technique for the experimental validation of stereotactic 3D treatment planning software.
Bercier, Yanic. "Image fusion for radiosurgery treatments of arteriovenous malformations." Thesis, McGill University, 2002. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=82830.
Full textThe plans of patients who had previously undergone radiosurgery at our institution employing SA images for localisation and MR images for delineation were investigated. MRA datasets were also acquired at the time of MR scanning employing the 3D TOF technique. Some ray-traced MRA images correlated well visually with the SA images, others presented inconsistencies which suggest that MRA should be used only as complement to SA images.
The role of the different modalities (M-RA, MR and SA) in the definition of target volumes is investigated by defining the target contours with different combinations of modalities within the interactive system. The target volumes drawn with different modalities were compared to a reference volume, drawn using MRA, MR and SA images, and presented underestimation and overestimation of target volumes ranging from 20% to 92% and from 3% to 40%.
The dosimetric implications of image fusion for target delineation are investigated by retrospective evaluation of the dose coverage of the reference target volume by the original treatment plan. Target coverage inferior to 60% of the reference target volumes by the original treatment plans was obtained for the patients. Treatment plan optimisation was performed to evaluate the possible dosimetric improvements resulting from image fusion for AVM target delineation. The plans were improved by employing three, eight and four isocentres for the 3 patients, and resulted in target coverage equal or superior to 98% for all three patients.
Tozer-Loft, Stephen M. "Dose volume analysis in brachytherapy and stereotactic radiosurgery." Thesis, University of Sheffield, 2000. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.366100.
Full textAshfaq, Awais. "Segmentation of Cone Beam CT in Stereotactic Radiosurgery." Thesis, KTH, Skolan för teknik och hälsa (STH), 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-193107.
Full textC-arm Cone Beam CT (CBCT) system har tack vare sitt kompakta format, flexibla geometri och låga strålningsdos startat en era av inbyggda 3D bildtagningssystem för styrning av terapeutiska och kirurgiska ingripanden. Elektas Leksell Gamma Knife Icon introducerade ett integrerat CBCT-system för att bestämma patientens position för operationer och på så sätt gå in i en paradigm av ramlös stereotaktisk strålkirurgi. Även om CBCT erbjuder snabb bildtagning med hög spatiel noggrannhet så tenderar de kvantitativa värdena att störas av olika artefakter som spridning, beam hardening och cone beam effekten. Ett flertal 3D rekonstruktionsalgorithmer som försöker reducera dessa artefakter kräver en noggrann och snabb segmentering av kraniofaciala CBCT-bilder i luft, mjukvävnad och ben. Målet med den här avhandlingen är att undersöka hur djupa neurala nätverk baserade på faltning (convolutional neural networks, CNN) presterar i jämförelse med konventionella bildbehandlings- och maskininlärningalgorithmer för segmentering av CBCT-bilder. CBCT-data för träning och testning tillhandahölls av Elekta. Ett ramverk för segmenteringsalgorithmer inklusive flernivåströskling (multilevel automatic thresholding), suddig klustring (fuzzy clustering), flerlagersperceptroner (multilayer perceptron) och CNN utvecklas och testas mot fördefinerade utvärderingskriterier som pixelvis noggrannhet, statistiska tester och körtid. CNN presterade bäst i alla metriker förutom körtid. Det genomsnittliga segmenteringsfelet för CNN var 0.4% med en standardavvikelse på 0.07%, följt av suddig klustring med ett medelfel på 0.8% och en standardavvikelse på 0.12%. CNN kräver 500 sekunder jämfört med ungefär 1 sekund för den snabbaste algorithmen, flernivåströskling på lika stora CBCT-volymer. Arbetet visar CNNs förmåga att handera artefakter och brus i CBCT-bilder och bibehålla en högkvalitativ semantisk segmentering. Vidare arbete behövs dock för att förbättra presetandan hos algorithmen för att metoden ska vara applicerbar i realtidsrekonstruktionsalgorithmer.
Sandström, Helena. "Contouring variability in radiosurgery - dosimetric and radiobiological implications." Licentiate thesis, Stockholms universitet, Fysikum, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-123252.
Full textAndisheh, Bahram. "Improving the therapeutic ratio of stereotactic radiosurgery and radiotherapy." Doctoral thesis, Stockholms universitet, Fysikum, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-81079.
Full textNya och förbättrade metoder för precisionsbestrålning, såsom intensitetsmodulerad strålbehandling (IMRT), stereotaktisk strålbehandling (SRT), stereotaktisk strålkirurgi (SRS) eller hadronterapi etc., gör det möjligt att leverera behandlingen i ett fåtal fraktioner med höga doser. Dessa behandlingmetoder kan ytterligare förbättras genom att (i) förbättra den fysikaliska dosfördelningen, (ii) optimera dosrater och fraktioneringsscheman eller (iii) modifiera dosresponsen hos tumörer eller normalvävnad. Olika strålmodaliteter och behandlingssystem har tagits fram för att kunna leverera bästa möjliga fysikaliska dosfördelning till targetvolymen samtidigt som dosen till frisk vävnad hålls så låg som möjligt. Även om användandet av radiobiologisk kunskap och modeller i klinisk rutin ännu är i sin linda så visar många studier att kinetiken för subletal reparation av strålskador har stor betydelse för strålresponsen. Syftet med denna avhandling är att visa hur dessa olika utvecklingsvägar kan användas för att förbättra behandlingsresultatet speciellt genom att studera vald strålmodalitet, dosrat och fraktioneringsschema samt radiobiologisk modellering. För arteriovenösa missbildningar (AVM) har även studerats hur strukturen hos angionätverket påverkar strålresponsen.
At the time of the doctoral defense, the following papers were unpublished and had a status as follows: Paper 3: Manuscript. Paper 4: Manuscript.
Charpentier, Pierre E. "Dosimetric evaluation of four techniques used in stereotactic radiosurgery." Thesis, McGill University, 2007. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=112386.
Full textDimitriadis, Alexis. "Assessing the dosimetric and geometric accuracy of stereotactic radiosurgery." Thesis, University of Surrey, 2017. http://epubs.surrey.ac.uk/813888/.
Full textJitprapaikulsarn, Suradet. "An Optimization-Based Treatment Planner for Gamma Knife Radiosurgery." Case Western Reserve University School of Graduate Studies / OhioLINK, 2005. http://rave.ohiolink.edu/etdc/view?acc_num=case1109959500.
Full textShihadeh, Fadi Easa. "Optimized and integrated alignment system for functional proton radiosurgery." CSUSB ScholarWorks, 2007. https://scholarworks.lib.csusb.edu/etd-project/3258.
Full textWenner, Lisa Ellen. "Using regression techniques for the automated selection of radiosurgery plans." Thesis, Georgia Institute of Technology, 2000. http://hdl.handle.net/1853/13706.
Full textFox, Timothy Harold. "Computation and optimization of dose distributions for rotational stereotactic radiosurgery." Diss., Georgia Institute of Technology, 1994. http://hdl.handle.net/1853/32843.
Full textHössjer, Simon. "3D/2D Image Registration for Patient Positioning in Stereotactic Radiosurgery." Thesis, KTH, Skolan för datavetenskap och kommunikation (CSC), 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-170639.
Full textInom tillämpningen av stereotaktisk strålkirurgi för behandling av hjärntumörer är det absolut nödvändigt att patienter positioneras inom millimeternoggrannhet för att undvika skada hos närliggande vävnad vid behandling. Vi undersöker hur trolig tekniken om digitaliserade återskapande röntgenbilder är som en registreringsmetod för patientpositionering i den här typen av mycket noggranna applikationer. Framförallt betraktas godtyckligt många projektionsvinklar och observerar dess effekt på registreringsnoggrannheten, eftersom de flesta tidigare presenterade registreringsmetoderna endast är baserade på två projektionsvinklar och sällan uppfyller det krav som ställs på noggrannhet. Tre olika tillvägagångssätt betraktas för hur flertalet projektionsvinklar kan kombineras till ett enda avståndsmått. Resultaten verkar tyda på att datortomografi medför noggrannheter väl inom ramen för stereotaktisk strålkirurgi, medan konstråledatortomografi i sitt nuvarande tillstånd inte verkar göra detta. Anledningar till denna olikhet tros vara problem med rekonstruktionsartefakter i modellen och otillräckliga avståndsmått.
Chua, T. T. Daniel, and 蔡清淟. "Stereotactic radiosurgery as salvage treatment for locally recurrent nasopharyngeal carcinoma." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2006. http://hub.hku.hk/bib/B37223513.
Full textJosefsson, Marcus. "Robust Optimization for Radiosurgery under the Static Dose Cloud Approximation." Thesis, KTH, Optimeringslära och systemteori, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-156415.
Full textAlexander, Dana J. "Dose accuracy of the CMS convolution algorithm for stereotactic radiosurgery." Diss., Online access via UMI:, 2009.
Find full textMalkoc, Veysi. "Sequential alignment and position verification system for functional proton radiosurgery." CSUSB ScholarWorks, 2004. https://scholarworks.lib.csusb.edu/etd-project/2535.
Full textPoffenbarger, Brett A. "Viability of an isocentric cobalt-60 teletherapy unit for stereotactic radiosurgery." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1998. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape10/PQDD_0007/MQ44248.pdf.
Full textSixel, Katharina E. (Katharina Elisabeth). "Measurements and Monte Carlo simulations of X-ray beams in radiosurgery." Thesis, McGill University, 1993. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=41242.
Full textThe measurements of radiosurgical x-ray beam parameters are presented. Monte Carlo simulations determine that a measured increase depth of dose maximum with increasing field size is a result of primary dose deposition in phantom for small diameter beams.
An analytical representation based on a curve-fitting process is developed to parametrize radiosurgical x-ray beam percentage depth doses as a function of depth in phantom, field diameter and beam energy using bi-exponential and polynomial functions.
Measurements of dose in the build-up region of x-ray beams ranging from 1 x 1 cm$ sp2$ to 30 x 30 cm$ sp2$ show that the depth of dose maximum increases rapidly with increasing field size at small fields, reaches a maximum around 5 x 5 cm$ sp2$ and then gradually decreases with increasing field size for large fields. Monte Carlo simulations attribute effect observed at large fields to the scatter contamination of the primary beam from the linac head. This scatter contamination is measured by a half-block technique and further experiments show that it consists of electrons originating in the flattening filter of the linac.
Thakur, Varun. "Planning and delivery comparison of six Linac-based stereotactic radiosurgery techniques." Thesis, McGill University, 2012. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=107888.
Full textCette étude présente la planification et la comparaison de livraison de doses de les techniques de traitement par accélérateur linéaire (linac) à base de radiochirurgie stéréotactique (RCS) actuellement disponibles pour la RCS des lésions crâniennes uniques. Au total, deux systèmes RCS (Novalis Tx, Cyberknife) et un système HI-ART TomoTherapy avec six techniques différentes de livraison de doses sont évalués. Trois techniques de livraison de doses d'un système Novalis Tx sont évalués: arcs dynamiques conformationnelles, radiothérapie avec modulation d'intensité statique non-coplanaire et les techniques de thérapie volumétrique par arc modulé (RapidArc) sont comparées avec la tomothérapie hélicoïdale par modulation d'intensité sur le système HI-ART TomoTherapy et la radiochirurgie robotique non-isocentrique à multiples chevauchements du système CyberKnife. Treize patients sont rétrospectivement sélectionnés pour l'étude. Les volumes cibles de chaque patient sont transférés sur un scan tomodensitométrique d'un fantôme Lucy (Standard Imaging Inc, Madison, WI, Etats-Unis) conçu pour l'assurance qualité des systèmes RCS. Afin d'évaluer les plans de traitements, plusieurs métriques de notation de conformalité telles que l'homogénéité et les gradients du plan de traitement sont calculées et comparées pour chacun des plans. Enfin, dans le but de vérifier la faisabilité de livraison clinique des plans de traitements et la précision de livraison des différents systèmes, quelques cibles sont délivrées sur chaque système. Une comparaison entre la dose prévue sur le système de planification du traitement et la dose délivrée sur un film de type GAFCHROMIC EBT (ISP, Wayne, New Jersey, USA) est effectuée par comparaison des profils de faisceaux de dose, des lignes de doses de même intensité (isodose) et en calculant l'indice gamma.
Rojas, Villabona Alvaro Alexander. "Optimisation of planning and delivery methods for Gamma Knife Stereotactic Radiosurgery." Thesis, University College London (University of London), 2018. http://discovery.ucl.ac.uk/10048270/.
Full textCadman, Patrick F. (Patrick Frank). "Target localization and treatment set-up verification in linear accelerator-based radiosurgery." Thesis, McGill University, 1992. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=61344.
Full textGianolini, Stefano. "Comparative treatment planning and dosimetry for stereotatic radiosurgery: Gamma knife versus adapted LINAC /." Zürich : ETH, 2006. http://e-collection.ethbib.ethz.ch/show?type=diss&nr=16814.
Full textRobar, James L. "Film dosimetry and three-dimensional verification of conformal dose distributions in stereotactic radiosurgery." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 2000. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape3/PQDD_0019/NQ48701.pdf.
Full textBercier, Yanic. "A multimodality image fusion and localisation system for radiosurgery treatments of arteriovenous malformations /." Thesis, McGill University, 2000. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=33379.
Full textGavriliouk, Elena O. [Verfasser]. "Unequal Sphere Packing Problem in the Context of Stereotactic Radiosurgery / Elena O Gavriliouk." Aachen : Shaker, 2007. http://d-nb.info/1170527167/34.
Full textSvensson, Jenni. "Multiobjective optimization in radiosurgery : How to approximate and navigate on the Pareto surface." Thesis, KTH, Optimeringslära och systemteori, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-145133.
Full textCancer är en allt vanligare dödsorsak i världen och strålterapi är en vanlig behandlingsmetod. Att ta fram en strålbehandlingsplan är en tidskrävande process för den ansvarige sjukhusfysikern eller läkaren. Ett sätt att korta ner denna tid är att förberäkna ett antal optimala behandlingsplaner och sedan välja mellan kombinationer av dessa i realtid. Planerna som tas fram med hjälp av en dual algoritm föreslagen av Bokrantz och Forsgren, är anpassade till Leksell Gamma Knife®. Ett grafiskt verktyg har skapats för att navigera mellan de förberäknade planerna, baserat på navigeringsverktyget beskrivet av Monz et al. Beräkningstiden för att ta fram planerna har studerats, tillsammans med olika faktorer som påverkar den. I anknytning till detta gjordes en enklare dimensionsanalys av lösningarna och de Pareto-optimala punkterna för att se om det är möjligt att reducera antalet dimensioner för att snabba upp beräkningstiden. Inga långtgående slutsatser kan dras angående detta, men möjligheten går inte att utesluta. Slutsatsen att försöka hålla antalet målfunktioner lågt för att få en så bra approximation som möjligt bekräftades
Courter, Erik Joseph-Leonard. "Use of ClearView Gel Dosimeter for Quality Assurance and Testing of Stereotactic Radiosurgery." Wright State University / OhioLINK, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=wright1466417256.
Full textNeupane, Mahesh Raj. "Optimization of a sequential alignment verification and positioning system (SAVPS) for proton radiosurgery." CSUSB ScholarWorks, 2005. https://scholarworks.lib.csusb.edu/etd-project/2784.
Full textTze, Mei-yu Jadie. "Is waiting time a quality service indicator for radiotherapy treatment? : the effect of waiting time on local tumour control for nasopharyngeal carcinoma patients in Hong Kong /." View the Table of Contents & Abstract, 2006. http://sunzi.lib.hku.hk/hkuto/record/B36887328.
Full textMassager, Nicolas. "Influence de la distribution de dose d'irradiation dans la variation de l'effet radiobiologique du traitement radiochirurgical par Gamma Knife." Doctoral thesis, Universite Libre de Bruxelles, 2008. http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/210380.
Full textDoctorat en sciences médicales
info:eu-repo/semantics/nonPublished
TAKAHASHI, HIROSHI, CHISA HASHIZUME, TAKAHIKO TSUGAWA, YOSHIMASA MORI, and TATSUYA KOBAYASHI. "PROGNOSTIC FACTORS FOR TUMOR RECURRENCE AFTER GAMMA KNIFE RADIOSURGERY OF PARTIALLY RESECTED AND RECURRENT CRANIOPHARYNGIOMAS." Nagoya University School of Medicine, 2012. http://hdl.handle.net/2237/16031.
Full textMilroy, Desmond. "Validation of a commercial Monte Carlo algorithm for stereotactic radiosurgery and stereotactic body radiation therapy." Thesis, McGill University, 2012. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=110472.
Full textCe mémoire visait à valider l'algorithme Monte Carlo (MC) dans le cadre du système de planification de traitement iPlan de BrainLab où il est conjointement utilisé avec le mode radiochirurgical stéréostatique (SRS) de l'accélérateur linéaire Novalis TX de Varian. Plus particulièrement, l'algorithme iplan a été validé en comparant les résultats obtenus avec un modèle BEAMnrc du mode SRS de Novalis TX. Le modèle BEAMnrc a été créé en modifiant un modèle existant d'accélérateur Varian afin d'y inclure le filtre compensateur SRS et le collimateur multilames de haute définition de Novalis TX (HD120MLC). La caractérisation de la source a utilisé une procédure récente pour ajuster l'énergie, la taille et l'ouverture angulaire de la source. Par ailleurs, un module multilames de BEAMnrc existant (DYNVMLC) a été reprogrammé pour simuler le collimateur multilames de haute définition (HD120MLC). Pour ce dernier, l'écart entre les lames et la densité des lames ont été ajustés de sorte que les simulations correspondent aux profils de fuites interlames mesurées par films. La validation de l'algorithme iPlan a été réalisée par comparaisons entre les deux codes MC et des mesures de films pour des champs définis par le collimateur multilames, pour des courbes de la dose en profondeur de champs carrés administrés sur des fantômes hétérogènes et de plans plus réalistes du point de vue clinique administrés sur un fantôme stéréostatique Lucy® et un fantôme de tête Rando®. La procédure de caractérisation de la source et la modélisation du collimateur multilames (HD120MLC) ont été réussies ainsi que les simulations ultérieures correspondaient bien aux mesures des facteurs d'ouverture, des profiles dans l'eau et des distributions de dose des champs définis par le collimateur multilames. Des différences ont été observées s entre les codes MC et les mesures de films, mais les calculs avec les codes IPlan MC et EGSnc correspondaient bien dans tous les cas. Ces résultats suggèrent que l'algorithme MC de Iplan peut prédire précisément les doses de rayonnement pour des champs complexes dans des medias hétérogènes.
Morales, Johnny Estuardo. "Advances in very small x-ray field dosimetry for circular cones used in stereotactic radiosurgery." Thesis, Queensland University of Technology, 2019. https://eprints.qut.edu.au/133137/1/Johnny_Morales_Thesis.pdf.
Full textHASHIZUME, CHISA, TATSUYA KOBAYASHI, YUTA SHIBAMOTO, TAKAHIKO TSUGAWA, MASAHIRO HAGIWARA, YOSHIMASA MORI, and HISATO NAKAZAWA. "Useful Base Plate to Support the Head During Leksell Skull Frame Placement in Gamma Knife Perfexion Radiosurgery." Nagoya University School of Medicine, 2014. http://hdl.handle.net/2237/19481.
Full textToreti, Dalila Luzia. "Aceite, comissionamento e controle de qualidade em radiocirurgia." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-23092011-155440/.
Full textStereotactic Radiosurgery is a treatment technique that uses narrow beams of radiation focused with great accuracy in a small lesion. The introduction of micro multileaf collimators (mMLC) allows this technique to reach a higher degree of dose conformation of the target lesion allowing a smaller irradiation of critical structures and normal tissues. This paper presents the results of the acceptance tests and commissioning of a Varian ® 6EX linear accelerator dedicated to radiosurgery associated with the BrainLab ® micro multileaf collimator installed in the Hospital das Clínicas da Faculdade de Medicina da USP (HC-FMUSP) and establish feasible quality assurance program for the services that employ this special technique. The results of the acceptance tests were satisfactory and are willing with the specifications provided by the manufacturer and the commissioning tests were within the international recommendations. The tests and measures that are part of quality control process should be specific to each treatment unit, and the need, frequency and levels of tolerance.
Winnenburg, Holger. "Qualitätssicherung in der Strahlentherapie spezifische Untersuchungen zur langzeitlichen Konstanz dosimetrischer und geometrischer Parameter beim Einsatz von Radiosurgery-Software /." [S.l.] : [s.n.], 2004. http://deposit.ddb.de/cgi-bin/dokserv?idn=970184905.
Full textantonio, santacroce Verfasser], Hans-Jakob [Gutachter] [Steiger, and Jörg [Gutachter] Schipper. "The role of radiosurgery for the management of benign intracranial meningiomas / santacroce antonio ; Gutachter: Hans-Jakob Steiger, Jörg Schipper." Düsseldorf : Universitäts- und Landesbibliothek der Heinrich-Heine-Universität Düsseldorf, 2018. http://d-nb.info/1149895683/34.
Full text