Dissertations / Theses on the topic 'Protesi totali'

To see the other types of publications on this topic, follow the link: Protesi totali.

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Protesi totali.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

BIGONI, MARCO. "Risultati clinici preliminari nela valutazione della massa ossea periprotesica in pazienti portatori di protesi totali di ginocchio." Bachelor's thesis, Università degli studi di Milano-Bicocca, 1996. http://hdl.handle.net/10281/38076.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

De, Scrilli Maria. "Analisi videofluoroscopica sul posizionamento delle componenti protesiche nella sostituzione totale di ginocchio: confronto fra due diversi sistemi innovativi." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2012. http://amslaurea.unibo.it/4254/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Marchezan, Walter. "Estudo comparativo de quatro materiais e de duas técnicas, simples e dupla, para moldagens funcionais em prótese total." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2004. http://hdl.handle.net/10183/6765.

Full text
Abstract:
Este trabalho avaliou comparativamente, em laboratório, a fidelidade dimensional de quatro materiais de moldagem usados nas moldagens finais em prótese total, um hidrocolóide irreversível (Hidrogum), um poliéter (Impregum) e dois silicones de adição (Honigum e Extrude), bem como a técnica de dupla moldagem, com ou sem alívio, usando o material Extrude de consistências média e leve. Para isto foi usado como corpo de prova um modelo metálico que simula um maxilar edêntulo, onde foram colocados quatro postes em forma do pirâmide, três truncadas, colocadas na crista do rebordo para medições horizontais, e uma inteira, que servia de referência para uma medição vertical. Com cada material ou técnica foram feitos dez moldes do modelo padrão, que foram vazados com gesso tipo IV. Os sessenta modelos obtidos, bem como o modelo-padrão, foram submetidos às medições das distâncias entre as referências situadas nas pirâmides, três medidas no sentido horizontal e uma no sentido vertical. Isto foi feito numa máquina para medição por coordenadas (tridimensionai), BRT-M507 fabricada pela Mitutoyo, com software Cosmos/Geopak-Win. Os resultados foram submetidos à analise de variância e testes complementares (Post Hoc Tests, de Duncan). A análise dos resultados mostra que quase todas as medidas no plano horizontal foram menores nas réplicas que no padrão, e que na medida vertical a discrepância entre os resultados foi maior, sendo umas medidas maiores e outras menores que no padrão. Estatisticamente, apenas numa das três distâncias avaliadas, Dist. 2, não houve diferença significativa entre os materiais. Concluiu-se que, com exceção do material Extrude em moldagem simples, os silicones e o poliéter tiveram desempenho semelhante, e que o hidrocolóide irreversível evidenciou os piores resultados. Outra conclusão foi que as duas técnicas de dupla moldagem usando materiais de consistências diferentes mostraram resultados semelhantes ao Honigum e Impregum, sendo mais precisas que estes na reprodução da altura, medida relacionada com a moldagem da zona de postdamming no paciente edêntulo.
APA, Harvard, Vancouver, ISO, and other styles
4

Cardoso, Luiz Antonio Morais 1963. "Programação de articuladores em protese total : comparação entre metodos." [s.n.], 1997. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289450.

Full text
Abstract:
Orientador: Jose Roberto Lovadino
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-23T03:09:08Z (GMT). No. of bitstreams: 1 Cardoso_LuizAntonioMorais_D.pdf: 1865461 bytes, checksum: eae73caa17a06a50397f7619a4458242 (MD5) Previous issue date: 1997
Resumo: Neste estudo foram considerados dois valores de grande interesse protético: inclinação da trajetória condílica ântero-posterior (guia condilar) e ângulo de Bennett. Essas duas grandezas serviram para referência de comparação entre dois métodos de programação de articuladores empregados na confecção de próteses totais. O primeiro método foi o chamado desgaste de Paterson que utiliza arcos de orientação com mistura abrasiva, que atritados pelo próprio paciente, conforma individualmente cada conjunto, que por sua vez, serve para programar o articulador. O segundo método, chamado técnica de Nóbilo, emprega o registro intra oral modificado, permitindo que as posições de interesse para a programação do articulador sejam definidas e tranferidas com o auxílio de moldagens vestibulares das posturas. Os métodos foram aplicados em 27 pacientes desdentados totais. Para a inclinação da guia condilar, o método de Paterson obeve média de 26,10 graus e o de Nóbilo 30,87 graus. Para o ângulo de Bennnett, o método de Paterson conseguiu 13,14 graus e o de Nóbilo 16,34 graus. Para ambos os valores protéticos a análise de variância considerou haver diferença entre os resultados obtidos pelos métodos. No entanto, em relação ao lado das articulações, nenhum método detectou diferença
Abstract: In this study were considerate two values with big prosthetic interest: anterior-posterior trajectory inclination of condyle and Bennett angle. These two greatness were useful for reference to compare two methods of articulators programation employed in dentures construclion. The first method was called Paterson abrasion that wich utilize orientation arcs with abrasive misture, frictioned for the own patient conform individualy each conjunct; that which in this way serve to articulator shedule. The second method, called Nobilo's technique used the intra-oral register modifyed, allowing to be defined to the articulator sheduling to be able to be defined and transfered with the vestibular posture impression. The methods were apliyed in 27 patients. To the inclination of condylar guide, the Paterson method got 26.10 grades and Nobilo's one got 30.87 grades. To the Bennett angle, Paterson method got 13.14 grades and Nobilo's one got 16.34 grades. To both prosthetic values, the variance analysis considered to the difference between the results got for the two methods. Never the lless in articulations side relation, no one method detected differences
Doutorado
Protese
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
5

Cottam-Howarth, Barry. "Towards PNA directed chemical total protein synthesis." Thesis, University of Leeds, 2007. http://etheses.whiterose.ac.uk/21098/.

Full text
Abstract:
This thesis is concerned wi.th the development of a novel methodology for the chemical synthesis of proteins. The methodology is expected to overcome limitations of current techniques for chemical synthesis of proteins that restrict the size of the target molecule to less than 150 amino acids. It is intended that the use of a DNA analogue, PNA, as a directing group will allow different short polypeptides to self-assemble into a desired target protein. The first chapter is an overview of literature concerning templated synthesis and the applications of PNA. Examples of simple mctal-templated synthesis are discussed however there is a particular focus on the work of David Liu and his DNA-templated synthesis. The uses of PNA in a number of diverse applications are presented along with brief comparative descriptions of PNA and DNA. A brief discussion of current methodologies for protein synthesis is then used to set the context for the project aims and a description of the proposed methodology. The second chapter details the effort made in modifying literature procedures to successfully develop the robust and reproduCible cqemistry required for multi-gram synthesis ofPNA monomers. The third chapter briefly discusses the computer-aided design of a pair of linker molecules that act as a bridge between polypeptides and their PNA directing groups. The challenging synthesis of these linker molecules is detailed and synthetic routes for the multi-gram synthesis of both are given. The fourth chapter charts the development of the solid-supported chemistry used to construct PNA-peptide chimeras with close attention to the challenges encountered with incorporating the linker molecules. Of the two chimera targets required. to examine PNA-directcd ligation, a multi-gram preparative synthetic route is presented for one chimera. A route that provides analytical quantities of the complementary chimera is also discussed. The fifth chapter presents the experimental procedures used for the synthesis of the compounds involved in this project. Analytical data and the characterisation of compounds are detailed for each compound where possible.
APA, Harvard, Vancouver, ISO, and other styles
6

Atay, Tolga Baydar Metin Lütfi. "Gelişimsel kalça displazisi zemininde gelişen koksartrozlarda total kalça protezi uygulamalarımız /." Isparta : SDÜ Tıp Fakültesi, 2004. http://tez.sdu.edu.tr/Tezler/TT00155.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Jamieson, Craig. "Total synthesis, structure and function of protein analogues." Thesis, University of Edinburgh, 1999. http://hdl.handle.net/1842/12283.

Full text
Abstract:
A previously unknown protein produced by an mRNA mutation has recently been identified in Alzheimer's patients. The protein, designated UbN, is composed of the first 75 residues of ubiquitin followed by an unrelated sequence of 20 residues. The synthesis of this 10.7kDa entity was carried out, as well as its purification which was based on a novel affinity support in conjunction with the tetrabenzofluoroene moiety. In vitro testing established how the protein could compromise the ubiquitin-dependent proteolytic system, hence exerting a toxic effect in Alzheimer's patients. The synthesis of an analogue of ubiquitin (76 residues, 8.5kDa), which contained the unnatural amino acid 2S, 4S-5-fluoroleucine in place of leucine at the 50 and 67 positions, has been carried out. A short purification and folding protocol was developed, and comparison of the analogue with the native structure was undertaken. A possible application of the analogue in the study of protein folding using 19F nmr has been examined.
APA, Harvard, Vancouver, ISO, and other styles
8

Wang, Siyao. "Total Synthesis of Homogeneous Glycopeptides and Glycoproteins." Thesis, The University of Sydney, 2018. http://hdl.handle.net/2123/18329.

Full text
Abstract:
Glycosylation is a ubiquitous post-translational modification of proteins. Access to pure glycoproteins is extremely challenging owing to the enzymatic glycosylation process which is not templated and, as such, affords heterogeneous mixtures of glycoforms. Chemical synthesis provides an attractive avenue to access homogeneously glycosylated peptides and proteins, thus providing a means to elucidate the role of specific glycan modifications on structure and function. This thesis outlined the development of a number of novel synthetic methods to access biologically important glycopeptides and glycoproteins in pure form. Examples would include the synthesis of an unusual glycan modification of arginine which is present on key proteins from pathogenic bacteria and the synthesis of a library of homogenously glycosylated chemokines and cytokines. The results from these studies would inform new anti-infective and anti-inflammatory strategies in the future.
APA, Harvard, Vancouver, ISO, and other styles
9

Smith, Sandra Ellen. "Evaluation of nutritional needs in total parenteral nutrition based on non-protein calories versus total calories." Thesis, This resource online, 1995. http://scholar.lib.vt.edu/theses/available/etd-03242009-040335/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Roche, Didier. "Synthese totale d'inhibiteurs de la protease du virus vih-1." Université Louis Pasteur (Strasbourg) (1971-2008), 1995. http://www.theses.fr/1995STR13057.

Full text
Abstract:
La protease aspartique codee par le virus de l'immunodeficience humaine (vih-1) est devenue une cible importante dans la lutte chimiotherapique contre le sida. Un blocage effectif de cette enzyme entraine l'arret de la post-transcription des genes viraux polyproteiniques gag et gag-pol, et produit des virions non infrectieux. Le travail decrit dans ce memoire porte sur la synthese asymetrique d'inhibiteurs dont l'affinite avecl'enzyme a ete prevue par modelisation moleculaire. Dans une premiere approche synthetique, nous avons etudie l'effet des bases dans les reactions d'addition des carbanions de sulfones sur des -alkoxyaldehydes. Nous avons obtenu des bons rendements et une bonne selectivite en utilisant la base de schwesinger tb1-p4. Nous avons montre que la reaction, qui est equilibree, pouvait etre controlee par un effet matrice de la base de schwesinger. Dans un deuxieme temps, nous avons realise la synthese des molecules cibles par l'ouverture regio et stereoselective d'un lactoepoxyde comportant tous les centres asymetriques dans leur configuration desiree. Cette synthese peut etre realisee sur des quantites importantes
APA, Harvard, Vancouver, ISO, and other styles
11

Sawada, Ryusuke, Runcong Ke, Toshiyuki Tsuji, Masashi Sonoyama, and Shigeki Mitaku. "Ratio of membrane proteins in total proteomes of prokaryota." THE BIOPHYSICAL SOCIETY OF JAPAN, 2007. http://hdl.handle.net/2237/9298.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Mangiaracina, Valeria. "Dispositivi ortopedici impiantabili su misura: studio di una protesi totale di caviglia con personalizzazione selettiva." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2021. http://amslaurea.unibo.it/23023/.

Full text
Abstract:
Con il seguente elaborato si vogliono esplorare le possibilità di una protesi totale per caviglia dal design ibrido, che sia per una parte personalizzato e quindi fedele alle dimensioni specifiche del paziente e per un’altra standardizzato. In fondo all’idea di una protesi dal design ibrido, vi è il desiderio di cogliere le diverse opportunità che le nuove tecnologie di stampa 3D sono in grado di fornire quando sono utilizzate per realizzare impianti protesici impiantabili. È stato infatti dimostrato che l’impianto di componenti protesici personalizzati di anca e ginocchio ha portato ad ottimi risultati, anche a distanza di diversi anni dall’intervento. Tuttavia, ad oggi, non esiste un mercato di protesi personalizzate per l’articolazione della caviglia. Gli impianti per caviglia attualmente utilizzati, infatti, offrono un numero limitato di taglie, basate su studi morfologici effettuati su grandi fette di popolazione. Una protesi ibrida potrebbe essere progettata in modo da avere superfici personalizzate dove strettamente necessarie a fornire la giusta congruenza con il paziente, mantenendo però una percentuale di design standard, con conseguenti costi e tempi ridotti. In questo elaborato si cercheranno di individuare le superfici protesiche che andrebbero personalizzate e quelle che, invece, potrebbero mantenere un design standard, assicurando allo stesso tempo una corretta biomeccanica, il corretto allungamento delle strutture legamentose, una scelta azzeccata dei materiali e degli eventuali rivestimenti per indurre l’osteointegrazione.
APA, Harvard, Vancouver, ISO, and other styles
13

Di, Fiore Adolfo. "Comparazione di tecniche di impronta digitali e tradizionali in protesi totale su impianti: studio multidisciplinare." Doctoral thesis, Università degli studi di Padova, 2018. http://hdl.handle.net/11577/3422797.

Full text
Abstract:
Revising the international literature extensively, it’s clear that data regarding the accuracy of the digital dental models generated by an intra-oral scanner for full-arch implant support rehabilitation are few and contradictory. Realistically, the cause of these discordant results has to be identified in inadequate evaluation methods. Thus, the aim of this doctoral research project is the development of a methodology for the evaluation of digital dental models accuracy in accordance with the industrial preparation protocols. Five macro-areas can be identified: a) design and development of the master model; b) calibration of the master model; c) data acquisition; d) meshes elaboration; e) data analysis (3D- distance and position analysis). Once the evaluation methodology has been defined, it will be possible to perform different types of analysis in the implant-prosthetic area. The purpose will be to define the accuracy of: a) three different scanning techniques; b) six different intra-oral scanners; c) traditional versus digital impression techniques. Interestingly, the advantage guaranteed by this evaluation method is twofold. It may provide the clinician a useful a tool to understand the possible critical issues related to the different intra-oral scanner systems currently available; and it will help in the evaluation of the better impression technique to adopt during clinical activity.
In letteratura mondiale pochi e contradditori sono gli articoli che valutano l’accuratezza delle impronte digitali generate da uno scanner intra-orale utilizzato in casi di riabilitazione full-arch su impianti. Analizzando nel dettaglio tutti gli articoli abbiamo individuato nella metodologia di valutazione la causa dei risultati disomogenei. Lo scopo di questa tesi di dottorato è di sviluppare una metodologia di valutazione dell’accuratezza per le impronte digitali che segua i protocolli ingegneristici utilizzati nei processi di sviluppo dei prodotti industriali. La metodologia di valutazione si suddivide in cinque macro aree: progettazione e realizzazione di un modello master, calibrazione del modello master, acquisizione dei dati, elaborazione delle mesh e analisi dei dati ( analisi 3D delle distanze e analisi 3D delle posizioni).Una volta messa a punto la metodologia di valutazione è possibile condurre diverse sperimentazioni nell’ambito implanto-protesico con differenti obbiettivi: valutazione dell’accuratezza di tre differenti tecniche di scansione ; valutazione dell’accuratezza di sei differenti scanner intra-orali e comparazione dell’accuratezza dell’impronta digitale con l’impronta tradizionale. La progettazione di questa metodologia di valutazione fornisce al clinico uno strumento per capire le possibili criticità dei differenti sistemi di scanner intra-orali presenti in commercio, ma soprattutto nel valutare quale tecnica di impronta presenta le migliori performance da applicare ai pazienti durante l’attività clinica quotidiana.
APA, Harvard, Vancouver, ISO, and other styles
14

Almeida, Maria Helena Waack de. "Influencia de tecnicas de polimerização sobre adaptação das bases de protese total." [s.n.], 1998. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289949.

Full text
Abstract:
Orientadores: Saide Sarckis Domitti, Simonides Consani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-23T15:36:03Z (GMT). No. of bitstreams: 1 Almeida_MariaHelenaWaackde_M.pdf: 4543291 bytes, checksum: e498330720bead407e49365e84feda17 (MD5) Previous issue date: 1998
Resumo: O objetivo desta pesquisa foi verificar as alterações de adaptação das bases de prótese total, confeccionadas com resina acrílica ativada termicamente, ocorridas sob a influência de 3 técnicas de polimerização: convencional, por calor seco e por energia de microondas. Foram confeccionados 30 modelos padrões em gesso pedra, a partir de um molde de borracha representando uma arcada superior desdentada normal. Sobre os modelos foram confeccionadas as bases de prova, que foram divididas aleatoriamente em 3 grupos de 10 elementos e incluídos. em mufla pela técnica convencional, a fim de receber os seguintes tratamentos experimentais: Grupo 01: prensagem com resina termopolimerizável (Clássico) e polimerização em banho de água aquecida a 74+2°C por 9 horas (método convencional). Grupo 02: prensagem com resina termopolimerizável (Clássico) e polimerização por calor seco (estufa) a 74+2°C por- 9 horas. Grupo 03: prensa$em com resina termopolimerizável (Acron MC) e polimerização em forno de microondas a 900 W por 3 minutos. A seguir, as bases em resina, limpas e acabadas, foram fixadas em seus respectivos modelos com adesivo instantâneo (Super Bonder). O conjunto base de prótese modelo de gesso foi posicionado e fixado em um aparelho específico para obtenção das secções. Orientados por .guias existentes na mesa de fixação, com auxílio de serra manual, foram executados 3 cortes látero laterais passando pela região correspondentes à distal de caninos direito e esquerdo (A), mesial de primeiros molares direito e esquerdo (B) e região "pos-dam" (C) e 3 cortes ântero-posteriores passando pela região correspondente à crista do rebordo direito (A) e esquerdo (C) e região mediana do palato (B). A alteração dimensional ocorrida na resina acrílica foi avaliada por meio de um microscópio comparador, em 5 pontos referenciais para cada tipo de corte. Os resultados numéricos obtidos foram submetidos à análise estatística e as médias ao Teste de Tukey ao nível de significância de 5%. Todas as técnicas avaliadas produziram distorções, sem diferença estatisticamente significante. Quando o desajuste foi analisado dentro de uma mesma técnica, verificou-se que no Grupo 01 (Termopolimerizadora) não houve diferença estatisticamente significante entre os cortes látero-laterais. Entretanto, no Grupo 02 (Estufa), o corte A foi semelhante ao B e o B ao C, enquanto no Grupo 03 (Microondas), os dados demonstraram o mesmo comportamento estatístico entre os cortes B e C, porém diferentes do A, que mostrou a melhor adaptação. Por outro lado, quando os cortes ântero-posteriores foram analisados, houve comportamento estatístico semelhante entre eles nas 3 técnicas de polimerização estudadas. Neste caso, o corte B foi diferente estatisticamente dos cortes A e C, mostrando o maior desajuste. Independente da técnica de polimerização e da localização dos cortes; não houve diferença estatística quando se comparou os índices de desajuste entre os cortes látero-Iaterais e ântero-posteriores
Abstract: The purpose of this study was to veri1)1 the denture bases accuracy, made with heat-cured acrylic resin, occurred under the influence of three cycles of polymerization: conventional, by dry heat and with microwave. energy. Thirty master cast were made in stone plaster from a rubber cast, representing a normal nondental arch. The experimental bases were made on the casts which were divided at randon into three groups of ten elements and included in flask by conventional technique in order to receive the following experimental treatments: Group 01: press with thermicpolymerized resin (Clássico) and polymerized with hot water bath at 74+2°C during 9 hours (conventional method). Group 02: press with thermic-polymerized resin (Clássico) and polymerized with dry heat (oven) at 74+2°C during 9 hours. Group 03: press with thermicpolymerized resin (Acron MC) and polymerized in microwave oven at 900 W during 3 minutes. Afterly the bases in clean and tlnished resin were atlxed on their casts with instantaneous adhesive. The plaster model-prosthesis bases set was positioned and atlxed on an especitlc instrument to obtain the sections. Guided by instruments on tlxation grip, with the aid of a manual saw, three saggital plane cuts were made on the corresponding region to the right crest of ridge (A) and left (C) and on the palatal median region (8) and 3 lateral plane cuts corresponding to the distal of right and left canines (A), right and left tlrst molars mesial (8) and pos-dam region (C). The occurred dimensional alteration on the acrylic resm was evaluated with a comparator microscope in 5 referential points to each kind of cut. The numerical results were submited to a statistical analysis and the averages by the Tukey Test to a significance levei of 5%. AlI the evaluated techniques caused distortions, without statistical significative difference. There wasn't any statistical significative difference on the sagittal plane and lateral plane cuts among the three studied polymerization techniques. When the disadjustement was analysed within the same techniques, it was verified that in Group 01 (thermicpolymerizer) there was no statistical significative difference among the lateral plane cuts. However, in group 02 (Oven), the cut A was similar to B and B to C and in group 03 (Microwaves) the datas showed the same statistical conduct between cuts B and C, but different from cut A, which showed the best adaptation . On the other hand, when the sagittal plane cuts were analys~d, there was a similar statistical conduct among them on the three studied polymerization techniques. In this case, the cut B was statisticalIy different from cuts A' and C, showing the biggest disadjustment
Mestrado
Protese
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
15

Sousa, Rodrigo Luiz dos Santos. "Inclinação dental em protese total em função de diferentes tecnicas de inclusão." [s.n.], 2004. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290542.

Full text
Abstract:
Orientador: Celia Marisa Rizzatti-Barbosa
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T03:43:59Z (GMT). No. of bitstreams: 1 Sousa_RodrigoLuizdosSantos_D.pdf: 5394210 bytes, checksum: 6cc0e505d12e21be6af73e2699dad266 (MD5) Previous issue date: 2004
Resumo: Este trabalho comparou a alteração da inclinação de primeiros molares de próteses totais obtidas pela utilização da mufla bimaxilar, com a de próteses totais obtidas em mufla monomaxilar, polimerizadas por energia de microondas (20 minutos a 20% de potência, mais 5 minutos a 60% de potência), e divididas aleatoriamente em 4 grupos, incluídos através dos seguintes protocolos: grupo 1 ¿ mufla monomaxilar e inclusão com gesso; grupo 2 ¿ mufla bimaxilar e muralha de silicone; grupo 3 - mufla bimaxilar e inclusão com gesso; grupo 4 ¿ mufla bimaxilar e muralha de silicone associada à retenção na face vestibular dos dentes. Foram confeccionados 40 pares de modelos em gesso tipo III, e sobre eles, obtidas matrizes de prótese total superior e inferior, a partir de dispositivos duplicadores e divididos em 4 grupos. Em seguida, foi confeccionada uma canaleta paralela à inclinação da vertente triturante da cúspide mésio-vestibular nos primeiros molares superiores e outra pararela à inclinação da vertente triturante da cúspide disto-vestibular para os inferiores. Em cada extremidade das canaletas foram determinados pontos referenciais com segmentos de alfinete. Em seguida, foram determinados os catetos de um triângulo imaginário, passando pelos pontos referenciais, com auxílio de um microscópio linear Olympus (0,0005 mm). Posteriormente, foi aplicado o teorema de Pitágoras e a fórmula do cosseno para determinação do ângulo de inclinação dos dentes antes e após o processamento das próteses. Os dados foram submetidos aos testes de correlação entre ângulos e de Kruskal-Wallis (5%). Não houve correlação entre os ângulos do lado direito e esquerdo de uma mesma prótese, como também entre ângulos os superior e inferior para os pares de prótese de todos os grupos estudados. Para o ângulo direito superior houve diferença estatística significante (p<0,05) entre os períodos antes e depois dos tratamentos para o grupo I (antes ¿ 39,64° e depois ¿ 40,79°), grupo II (antes ¿ 38,20° e depois ¿ 39,66°), grupo III (antes ¿ 39,14° e depois ¿ 40,12°), mas não houve diferença estatística significativa (p<0,05) entre os períodos antes e depois para o grupo IV (antes ¿ 39,49° e depois ¿ 40,73°). Para o ângulo direito inferior houve diferença estatística significante (p<0,05) entre os períodos antes e depois de aplicados os tratamentos para o grupo II (antes ¿ 37,92° e depois ¿ 38,47°) e grupo IV (antes ¿ 39,54° e depois ¿ 40,22°), mas não houve diferença estatística significativa (p<0,05) entre os períodos antes e depois para o grupo I (antes ¿ 38,11° e depois ¿ 38,22°) e grupo III (antes ¿ 39,46° e depois ¿ 39,60°). Para o ângulo esquerdo superior houve diferença estatística significativa (p<0,05) entre os períodos antes e depois de aplicados os tratamentos para o grupo I (antes ¿ 38,89° e depois ¿ 39,95°), grupo II (antes ¿ 39,47° e depois ¿ 40,26°), grupo III (antes ¿ 38,45° e depois ¿ 40,11°) e grupo IV (antes ¿ 41,98° e depois ¿ 43,04°). Para o ângulo esquerdo inferior houve diferença estatística significativa (p<0,05) entre os períodos antes e depois de aplicados os tratamentos para o grupo III (antes ¿ 40,35° e depois ¿ 39,81°) e grupo IV (antes ¿ 39,82° e depois ¿ 40,25°), mas não houve diferença estatística significativa (p<0,05) entre os períodos antes e depois para o grupo I (antes ¿ 39,57° e depois ¿ 40,34°) e grupo II (antes ¿ 38,84° e depois ¿ 39,69°). As médias de todos os ângulos estudados, não apresentaram diferença estatística significativa (p<0,05) entre si para os grupos I, II, III e IV, antes e depois de aplicados os tratamentos. Diante do exposto, foi possível concluir que as alterações de inclinação observadas estabeleceram similaridade para os tipos de muflas e de materiais de inclusão
Abstract: The purpose of this study was to evaluate first molar inclination in maxillary and mandibular complete dentures processed in monomaxilary and bimaxillary flasks by microwave irradiation (at 20 % power for 20 minutes and 60% power for 5 minutes). Forty pairs of type-III-stone models were obtained, and complete dentures were waxed and standardized with a special appliance. Dentures were divided in four groups, according to flasking and processing procedures: group 1 ¿ flasking with stone in monomaxillary flasks; group 2 ¿ flasking with silicone rubber and stone in bimaxillary flasks; group 3 --¿ flasking with stone in bimaxillary flasks; group 4 ¿ acrylic resin retentions were confectioned on buccal tooth surfaces, and flasking were taken with silicone rubber in bimaxillary flasks. For each tooth, two reference points were determined (in mesiopalatine and distobuccal cusps for maxillary first molars and in mesiobuccal and distolingual cusps for mandibular first molars). A linear comparator microscope (Olympus, 0.0005 mm tolerance) was used to measure the distance between two reference points, determining a triangle side. Using Pitagora¿s Theorem and Cossen Law, tooth inclination angles were calculated. Data were submitted to Correlation test and Kruskal-Wallis (5% significance). There was no correlation between right and left side angles and no correlation between maxillary and mandibular angles for all groups. For maxillary right angle, there were significant statistical differences (p<0.05) before and after processing among groups I (39.64° and 40.79°, respectivelly), II (38.20° and 39.66°) and III (39.14° and 40.12°). However, for group IV, there was no significant statistical difference (p>0.05) before and after processing (39.49° and 40.73°). For mandibular right angle, there were significant statistical differences (p<0.05) before and after processing between groups II (37.92° and 38.47°) and IV (39.54° and 40.22°). However, there was no significant statistical difference (p>0.05) between groups I (38.11° and 38.22°) and III (39.46° and 39.60°). For maxillary left angle, there were significant statistical differences (p<0.05) before and after processing among groups I (38.89° and 39.95°), II (39.47° and 40.26°), III (38.45° and 40.11°) and IV (41.98° and 43.04°). For mandibular left angle, there were significant statistical differences (p<0.05) between groups III (40.35° and 39.81°) and IV (39.82° and 40.25°). However, there was no significant statistical difference (p>0.05) before and after processing between groups I (39.57° and 40.34°), and II (38.84° and 39.69°). Regarding angle mean values, there was no significant statistical difference (p<0.05) before and after processing for all groups. It could be concluded that alterations observed in tooth inclination were similar for all flasking and processing procedures
Doutorado
Protese Dental
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
16

Humphries, A. C. "The total synthesis of the protein phosphatase inhibitor okadaic acid." Thesis, University of Cambridge, 1999. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.604785.

Full text
Abstract:
This thesis is divided into seven chapters. The first is a brief discussion of the structure, regulation and rôle of the protein phosphatases in biological systems, with particular emphasis on the important contribution made by the protein phosphatase inhibitor okadaic acid. The second chapter is a review of published synthetic work towards okadaic acid by other research groups. Chapter three begins with a brief review of some synthetic strategies towards the spiroketal unit. The general approach adopted within these laboratories for the total synthesis of okadaic acid is then described, with disconnections giving three distinct spiroketal units; followed by the synthesis of the central fragment. The fourth chapter describes the novel, intermolecular C-glycosylation of a 2-oxy substituted glycosyl sulfone. The application of this methodology to the introduction of a formyl unit into the anomeric position of the central spiroketal fragment is then described. Chapter five details a novel strategy towards the synthesis of the C15-C38 portion of okadaic acid, using the C-glycosylation methodology for the direct coupling of the C14-C26 and the C27-C38 fragments. It also contains a brief summary of the synthesis of the C27-C38 fragment from these laboratories. Chapter six begins with a review of the synthesis of the C1-C14 fragment from these laboratories. The coupling of the two advanced fragments is then detailed, together with the completion of the total synthesis.
APA, Harvard, Vancouver, ISO, and other styles
17

Katz, Roni. "Protein metabolism in septic patients ungergoing [sic] total parenteral nutrition /." Bern : [s.n.], 1989. http://www.ub.unibe.ch/content/bibliotheken_sammlungen/sondersammlungen/dissen_bestellformular/index_ger.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Monti, Alessandro. "Valutazione dell'impingement femoro-acetabolare nella protesica totale d'anca mediante video-fluoroscopia tridimensionale." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2017.

Find full text
Abstract:
Questo lavoro di tesi di laurea prende origine da un progetto nato dalla collaborazione dell'azienda DePuy con l'Istituto Ortopedico Rizzoli, centro di ricerca operante nel settore biomeccanico. Tale ricerca riguarda la protesica totale di anca ed ha come scopo la valutazione di quelle situazioni a rischio di impingement, ovvero di contatto patologico tra il collo del femore e la coppa acetabolare da evitare in quanto genera un punto di leva e può dunque portare alla dislocazione della protesi. Si vuole effettuare una comparazione in vivo di tre differenti taglie di protesi totali di anca distinte tra loro per il diametro della testa del femore in testine grandi (36 e 40 mm) e testine piccole (28 mm). Questo è stato testato nei movimenti di statica frontale, accovacciamento, affondo avanti, affondo indietro, flessione su sedia, seduta incrociata e squat, movimenti della vita quotidiana portati ai loro limiti estremi in modo da stressare l'articolazione. Si vuole confermare ciò che già era presente in letteratura solo tramite test in vitro, ovvero che effettivamente le protesi con diametro della testa del femore maggiore allontanano questo pericolo di impingement e stabilizzano il Range of Motion post-operatorio nel paziente. Il metodo di analisi scelto per l'indagine è la fluoroscopia tridimensionale. La procedura è stata approvata dal comitato etico ed inserita su ClinicalTrials.gov. Dapprima si andranno a definire a livello anatomico le zone di interesse dello studio, quindi si analizzerà l'articolazione dell'anca. Dunque saranno introdotti i due principali metodi per l'analisi biomeccanica: la videofluoroscopia e la gait analysis. Sarà poi effettuata una revisione della letteratura sul tema. Si analizzerà quindi l'acquisizione e l'elaborazione dei dati, dall'approccio con il paziente all'elaborazione via software alla statistica inter-paziente sui singoli movimenti per le diverse taglie. Si propongono poi le conclusioni da qui desumibili.
APA, Harvard, Vancouver, ISO, and other styles
19

Albrecht, Brian Keith. "A concise total synthesis of the TMC-95A and TMC-95B proteasome inhibitors." Access citation, abstract and download form; downloadable file 12.48 Mb, 2004. http://wwwlib.umi.com/dissertations/fullcit/3131652.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Oliveira, Junior Norberto Martins de [UNESP]. "Estudo comparativo entre dois adesivos no desempenho mastigatório de usuários de próteses totais." Universidade Estadual Paulista (UNESP), 2014. http://hdl.handle.net/11449/110831.

Full text
Abstract:
Made available in DSpace on 2014-12-02T11:16:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-07Bitstream added on 2014-12-02T11:21:06Z : No. of bitstreams: 1 000792994.pdf: 1161267 bytes, checksum: 9a60b292709b40dca901efbce97149e7 (MD5)
Proposição: O objetivo deste estudo foi avaliar o efeito da utilização de dois adesivos para prótese em relação ao desempenho mastigatório de usuários de próteses totais convencionais, por meio de um estudo “cross-over”. Material e Método: Cinquenta indivíduos totalmente desdentados receberam novas próteses totais bimaxilares e, após o período de adaptação posterior à instalação, foram submetidos à análise do desempenho mastigatório com as próteses sem adesivos protéticos (controle). Posteriormente, a amostra foi dividida aleatoriamente e designada a dois protocolos, nos quais a ordem de uso dos adesivos era diferente. Os adesivos Ultra Corega creme e Ultra Corega pó foram utilizados por 15 dias previamente à aplicação de novas análises do desempenho mastigatório, por toda a amostra, e respeitando-se um período de descanso (washout), também de 15 dias, entre o uso de cada adesivo. O desempenho mastigatório foi avaliado pelo método dos tamises. Os dados obtidos foram submetidos ao teste não-paramétrico de Friedman e comparação múltipla de média de ordens utilizando o teste de DUNN (α=0,05). Resultados: Houve aumento significativo do desempenho mastigatório após uso dos adesivos Ultra Corega creme (med=27,4%) e Ultra Corega pó (med=28,0%), quando estes foram comparados ao grupo controle (med=16,5%) (p<0,001; n=30), não havendo diferença estatisticamente significante entre os adesivos testados (p=0,897; n=30). Conclusões: O uso de adesivos aumentou o desempenho mastigatório de usuários de próteses totais convencionais, e não houve diferença para o desempenho mastigatório quanto ao uso de adesivos nas formas de creme e pó.
Objective: The objective of this study was evaluate the effect of use of two denture adhesives in relation to masticatory performance of conventional complete denture wearers, by means of a cross-over study. Material and Method: Fifty edentulous individuals received new bimaxillary complete dentures and, after the adaptation period, were submitted to masticatory performance analysis with complete dentures without adhesives (control). So, the sample was randomly divided and assigned to two protocols, in which the adhesives order of use was different. The adhesives Ultra Corega cream and Ultra Corega powder were used for 15 days prior the application of new masticatory performance analysis, by all the sample, and respecting a washout period, also 15 days, between the use of each adhesive. The masticatory performance was evaluated by sieves method. Data were analyzed by nonparametric Friedman test and multiple comparison of average orders using test DUNN (α=.05). Results: There was significant increase in masticatory performance after use of adhesives Ultra Corega cream (med=27.4%) and Ultra Corega powder (med=28.0%), when these were compared to the control group (med=16.5%) (p<.001; n=30), without statistically significant difference between the tested adhesives (p=0,897; n=30). Conclusions: The use of adhesives increased masticatory performance of conventional complete denture wearers, and there was no difference for masticatory performance as the use of adhesives in the forms of cream and powder.
APA, Harvard, Vancouver, ISO, and other styles
21

Silva, Wilkens Aurelio Buarque e. 1967. "Estabilidade mecanica de proteses fixas sobre retentores do tipo coroa total." [s.n.], 1996. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289086.

Full text
Abstract:
Orientador: Frederico Andrade e Silva
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-21T21:22:32Z (GMT). No. of bitstreams: 1 Silva_WilkensAurelioBuarquee_D.pdf: 4715185 bytes, checksum: 2f0fd4a9ae36d7a9ec0b70f8bd967723 (MD5) Previous issue date: 1996
Resumo: O objetivo deste trabalho foi avaliar a estabilidade mecânica de pontes fixas, através da variação de forças compressivas verticais, de sentido ocluso cervical, aplicadas nas vertentes oclusais internas dos retentores e pônticos; sendo os corpos de prova adaptados em preparos do tipo coroa total, com e sem canaletas axiais proximais e variando-se a convergência das paredes axiais. Os preparos com 5mm de altura cervico-oclusal e ombro maior que 90°, foram confeccionados com as seguintes convergências: 16°, 24° e 32° de convergência total, com e sem canaletas axiais proximais (0,7mm de profundidade e 4mm de altura). Para cada hemi-arco foi confeccionado um corpo de prova com características morfofuncionais de uma ponte fixa, cujos retentores foram o 2° molar e o 2° pré-molar, e pônticos o 1° molar e o 1° pré-molar (pôntico em "cantilever"). Para avaliação da estabilidade mecânica, os corpos de prova adaptados em seus respectivos preparos, foram submetidos à cargas verticais de intensidade 3kg, 5kg, 10kg, 15kg e 20kg em uma máquina de ensaio universal, com velocidade' constante em 1mm/min. O registro dos resultados consistiu em observar a ocorrência ou não de deslocamento dos corpos de prova. Os resultados obtidos revelaram que: a) Os retentores adaptados sobre preparos com 12° e 16° em cada parede axial, sem canaletas axiais proximais, obtiveram médias de deslocamento significativamente superiores aos adaptados em preparos com 8°; b) O aumento na intensidade das forças compressivas diminuiu a estabilidade dos corpos de prova. c) As forças induzidas no "cantilever", proporcionaram as maiores médias de deslocamento; d) As canaletas axiais proximais reduziram significativamente as médias de deslocamentos dos corpos de prova nos grupos com 12° e 16° de convergência em cada parede axial; e) As canaletas axiais proximais não foram devidamente efetivas em antagonizar as forças induzidas no "cantilever"
Abstract: The purpousal of this research, was to evaluate the mechanical stability of full crown preparations, over vertical compressive forces, applied in the occlusal vertents of the pontics and retainers of fixed partial prothesis, with or without the presence of proximal axial grooves, changing the convergence of the axial walls. The preparations with sholder larger than 90°, were made with the following convergences: 8°, 12° and 16° in each of the axial walls, with or without proximal axial grooves, of 0,7mm deep and 4mm length. The cervico-occlusal height of the preparations was 0,5mm. For each hemi-archs, was made a pattern like a four elements fixed partial denture: 2nd. molar (retainer), 1st. molar (pontic), 2nd. pre-molar (retainer) and the 1st.pre-molar (cantilever). To evaluate the resistance form of the preparations, the pattern adjusted in yours respective preparations, were submited to vertical forces of intensity 3kg, 5kg, lOkg, 15kg and 20kg in a universal testing machine, with speed in 1mm/min. The record of the results was to observe the occours of dislodgement of the patterns. The obtained results shows: a) the retainers adjusted in 12° and 16° preparations, had statisticaly higher average of dislocation to the adjusted in 8°; b) The increase of vertical force, decreased the the stability; c) The vertical force induced in the cantilever, provides the higher averages of dislocation; d) The proximal axial grooves decreased the average of dislocation, in 12° and 16° preparations groups; e) The proximal axial grooves, were not completely effective in provides stability, on cantilever pontics
Doutorado
Protese Dental
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
22

Tavares, Rui. "Avaliação da resistencia de fundações de amalgama, atraves da tração de coroas totais metalicas." reponame:Repositório Institucional da UFSC, 1988. http://repositorio.ufsc.br/xmlui/handle/123456789/75461.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro de Ciencias da Saude
Made available in DSpace on 2012-10-16T01:31:54Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T16:10:25Z : No. of bitstreams: 1 83551.pdf: 1073025 bytes, checksum: db0497039a440199fc1cca9fadf9fb2c (MD5)
O presente trabalho de pesquisa avalia a resistência às forças de tração de coroas de níquel-cromo cimentadas a fundação de amálgama retidas os "amalgapin" e fendas totais e parciais. Cinqüenta pré-molares superiores recém extraídos, de tamanhos semelhantes, foram separados em 5 grupos (I, II, III, IV e V) de 10 elementos cada um, inseridos numa base de resina acrílica e mantidos em água a temperatura ambiente durante todas fases da pesquisa. Os grupos I, II e V tiveram todas as cúspides parcialmente desgastadas. Nos grupos III e IV a cúspide vestibular permaneceu intacta enquanto a cúspide palatina foi desgastada. Os dentes do grupo I, II e III foram restaurados com amálgama retido por 6, 4 e 2 "amalgapin", enquanto os do grupo I e IV tiveram suas restaurações retas por fendas parcial e total, respectivamente. Todos os dentes foram preparados para receber coroas totais metálicas fundidas em liga de níquel-cromo. Os preparos com 2 mm cervical em dentina para todos os dentes e 2 mm em amálgama (grupos I, II e V) ou em amálgama e dentina (grupos III e IV) na porção oclusal apresentavam ombro chanfrado de aproximadamente 0,5 mm de profundidade.
APA, Harvard, Vancouver, ISO, and other styles
23

Oliveira, Viviane Maia Barreto de. "Efeito de um limpador de protese na concentração de compostos sulfurados volateis e na microbiota bucal de pacientes idosos institucionalizados portadores de proteses totais." [s.n.], 2003. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287935.

Full text
Abstract:
Orientadores: Altair A. Del Bel Cury, Pedro Luiz Rosalen
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-03T18:53:40Z (GMT). No. of bitstreams: 1 Oliveira_VivianeMaiaBarretode_D.pdf: 3110818 bytes, checksum: 40e9aa33bfe2bfa6fd45609e4b286025 (MD5) Previous issue date: 2003
Resumo: O objetivo deste estudo foi verificar a eficácia do limpador de prótese Polident 5 minutes@ (Block and Drug Corp.) quanto à redução da concentração de Compostos Sulfurados Voláteis (CSV), por meio do Halimeter@ (Interscan Corp.) e a ação bactericida pela cultura microbiana em ágar sangue e MacConkey, além de avaliar a correlação entre a habilidade em higienizar as próteses (HA) e o índice de biofilme (IB) sobre as mesmas. Foram selecionados 19 voluntários, com idades entre de 62 a 86 anos, portadores de pelo menos prótese total superior. As análises foram realizadas em duas fases (F). FI: avaliação m e verificação HA, determinação da concentração de CSV e coleta do biofilme das próteses antigas, nos tempos To (sem uso do limpador), TI, T2eT3 (uso contínuo do limpador por 7, 14 e 28 dias); FII: novas próteses foram instaladas, a concentração de CSV foi determinada e o biofilme foi coletado após 30, 60 e 90 dias de uso contínuo do limpador (Tu, T2.2, T3.3). Os resultados para a concentração de CSV apresentaram diferença estatística entre os períodos Toe TI, e Tu e T 2.2, verificada pelo 64, 67A; T3.3: 53,67B. Na avaliação de microrganismos crescidos em aerobiose os resultados não mostraram diferença estatística significativa na FI e na F 11 houve diferença estatística entre todos os tempos, verificada pelo Teste T pareado (p<0,05): To: 3,34a; TI: 2,22a; T2: 2,92a; T3: 4,24a; Tu: O, 14c; T2.2: 1,12B; T33: 2,74B. Concluiu-se que houve uma correlação positiva entre a HA e m, que o limpador não foi eficaz na remoção do biofilme aderido à prótese antiga e não impediu a formação de biofilme nas novas próteses, assim como não reduziu os níveis de CSV dos pacientes
Abstract: The purpose of this study was to determine the effectiveness of the Polident 5 minutes@ (Block and Drug Corp.) denture cleanser in reducing V olatile Sulphur Compounds (VSC) concentration, estimated by Halimeter@ (Interscan Corp.) and the bactericide action by Blood Ágar and MacConkey culture, besides evaluating the correlation among the denture cleaning dexterity (DC) and the biofilm index (BI). 19 volunteers were selected with age range 62 to 86 years, wearing at least the upper denture. The analysis was conducted in two phases (P): PI: BI evaluation, volunteers DC, determination of VSC concentration and the biofilm was collected ITom the old denture before the use of the treatment protocol (To), and after 7, 14 and 28 days of continuous cleanser use (TI, T2 and T3); Pu: new denture was installed, VSC concentration was determinated and biofilm was collected at 30, 60 and 90 days with daily use ofthe denture cleanser (Tu, T2.2, T3.3). The VSC concentration results showed statistical difference between To and results did not show statistical difference at Phase I and, at Phase 11, there was statistical difference between alI the times, by paired-T test (p<0.05): To: 3,343; TI: 2,223; T2: 2,923; denture cleanser was not efficient to remove the old denture biofilm, did not prevent the new denture biofilm and did not reduce patients VCS levels
Doutorado
Protese Dental
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
24

Cunha, Hiron Andreaza da. "Avaliação das próteses fixas totais sem estrutura metálica, implantossuportadas com carga imediata." reponame:Repositório Institucional da UFSC, 2012. http://repositorio.ufsc.br/xmlui/handle/123456789/91596.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2008
Made available in DSpace on 2012-10-24T00:37:30Z (GMT). No. of bitstreams: 1 269710.pdf: 1134622 bytes, checksum: d50293ec4a3817531c6d02ee4992e1b5 (MD5)
Por meio deste estudo foi analisado o comportamento clínico das próteses fixas implantossuportadas sem infra-estrutura metálica submetidas à carga imediata, como tratamento definitivo, em dez pacientes que receberam cinco implantes na mandíbula entre os foramens mentual, somando um total de 50 implantes, cada paciente recebendo uma prótese fixa de 12 elementos sem infra estrutura metálica e uma prótese total superior. Este estudo avaliou ao mesmo tempo a estabilidade inicial e secundaria dos implantes por um período de 24 meses, por meio do Osstell, aparelho que afere a estabiliade do implante por meio de freqüência de ressonância. Os resultados da análise descritiva apresentaram em média uma estabilidade inicial de 71.76 ISQ (Quociente de estabilidade do implante), a estabilidade secundária em média após 6 meses foi de 69,35 ISQ, 12 meses foi de 70.14 ISQ e 24 meses foi de 70.10 ISQ (Quociente de estabilidade do implante), indicando que os implantes estavam estáveis após 24 meses em função. Os resultados são favoráveis aos itens avaliados, não houve fraturas das próteses, não houve afrouxamento ou fraturas dos parafusos de retenção, não houve perda de implantes de nenhum dos cinqüenta implantes instalados, demonstrando ser viável o uso dessa técnica.
This study analyzed the clinical behavior of the implants, submitted to a immediate loading with fixed prosthesis implantsupported without a metallic infrastructure by means of Osstell, for a period of twenty-four months, in ten patients, who received five implants in the mandible between the mentonian foramens, with a total of 50 implants, each patient received a fixed prosthesis of 12 elements without a metallic structure and a superior total prosthetics. During this period it was also evaluated the clinical behavior of the prosthesis, as to the resistance to fracture of the acrylic resin, the unscrewing and fracture of the retention screws of the prosthesis in the masticating function. The results of the descriptive analysis presented an initial stability of 71.76 ISQ (Implant Stability Quotient). The secondary stability, after 6 months, was of 69,30 ISQ; 12 months, was of 68.04 ISQ; after 24 months, was of 69.48 ISQ, indicating that the implants were stable after 24 months of function. There were no losses of implants during this period. The results were favorable to the evaluated items, the initial and secondary stability remained in normal values, and there were no fractures of the prosthesis, no loosening or fractures of the retention screws, there were no losses of the fifty implants installed, during the period of study of 24 months, showing a viable use of this technique.
APA, Harvard, Vancouver, ISO, and other styles
25

Leite, Andressa Rosa Perin [UNESP]. "Avaliação de aspectos relacionados á utilização de um adesivo para próteses totais convencionas: estudo in vitro." Universidade Estadual Paulista (UNESP), 2013. http://hdl.handle.net/11449/97326.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-13Bitstream added on 2014-06-13T18:58:08Z : No. of bitstreams: 1 leite_arp_me_arafo.pdf: 1273945 bytes, checksum: cb5883147f849ba467e943f22b736489 (MD5)
O objetivo do presente estudo foi avaliar a influência da utilização de um adesivo para prótese (Ultra Corega creme) na formação de biofilme sobre a superfície interna de próteses totais e na microbiota bucal, no grau de satisfação, além da estimativa de custo médio diário do produto. Trinta pacientes receberam próteses totais novas, e foram divididos em dois protocolos: protocolo 1- utilização do adesivo durante os primeiros 15 dias de teste, seguida por não utilização de nenhum tipo de adesivo durante os próximos 15 dias; protocolo 2- não utilização de adesivo durante os primeiros 15 dias de teste, seguida por utilização do adesivo durante os próximos 15 dias. Após cada período de 15 dias, o biofilme formado na superfície interna das próteses totais foi corado e quantificado por meio de um método fotográfico com o auxílio de um software (Image Tool 3.00). Amostras de material da mucosa palatina e da superfície interna das próteses superiores foram plaqueadas em meios seletivos para Candida spp. e Streptococcus mutans e em um meio não seletivo. Ainda, foi aplicado um questionário para avaliação da satisfação com as próteses e o custo médio diário do produto foi estimado por meio de fórmulas matemáticas. Todas as análises foram realizadas com α = 0,05 e foram empregados testes apropriados à distribuição dos dados. Foi observada formação de biofilme semelhante com ou sem o uso do adesivo sobre as próteses superiores (Wilcoxon, p=0,255) e inferiores (Wilcoxon, p=0,433). Contagens de colônias semelhantes foram observadas com ou sem a utilização do adesivo na mucosa e na superfície interna da prótese total superior (p>0,05). O uso de adesivo proporcionou maior satisfação aos participantes (Wilcoxon, p=0,04). Em média, cada paciente utilizou 3,9 ± 0,3 gramas de adesivo por dia...
The aim of this study was to evaluate the influence of adhesive usage (Ultra Corega cream) on biofilm formation on the internal surface of dentures and oral microbiota, degree of satisfaction, and the estimated average daily cost of product. Thirty patients received new dentures, and have been divided into two protocols: Protocol 1-use of the adhesive during the first 15 days of the test, followed by not using adhesive over the next 15 days; Protocol 2- no use of adhesive for the first 15 days of the test, followed by use of adhesive over the next 15 days. After each period of 15 days, the internal surfaces of the dentures were stained and photographed and the areas (total internal surface and surface stained with biofilm) quantified (Image Tool 3.00). Samples of material from the palatal mucosa and the internal surface of the maxillary denture were plated on selective media for Candida spp. and Streptococcus mutans and a non-selective medium. A questionnaire was applied to evaluate satisfaction with the dentures and the average daily cost of the product was estimated by mathematical formulas. All analyzes were performed with α=.05 and appropriate tests were applied to the data distribution. Similar biofilm formation was found with or without adhesive usage for maxillary (Wilcoxon, p=.255) and mandibular dentures (Wilcoxon, p=.433). Similar colony counts were observed with or without adhesive for mucosa and the internal surface of dentures, irrespective of the culture medium (p>.05). The use of adhesive provided higher satisfaction (Wilcoxon, p=.04). On average, each patient used 3.9 ± 0.3 grams of adhesive per day, equivalent to R $ 4.02 for average daily cost. It is concluded that the use of the adhesive did not affect the quantification of the biofilm and the oral microbiota, besides providing greater overall satisfaction
APA, Harvard, Vancouver, ISO, and other styles
26

Smith, Rachel Ann-Selina. "Detection of protein interactions at cellular membranes using total internal reflection ellipsometry." Thesis, Sheffield Hallam University, 2015. http://shura.shu.ac.uk/20382/.

Full text
Abstract:
The targeting and subsequent interaction of proteins with membranes and membrane bound receptors is central to numerous cellular processes. Membrane bound receptors play a vital function in cell signalling, and are thus a target for many drugs, whereas aberrant membrane interactions play a major role in human amyloid diseases such as Parkinson's disease. The analysis of these interactions in their native environments poses problems, due to the technical difficulty in depositing membranes for analysis by conventional techniques such as, surface plasmon resonance (SPR). The optical method of spectroscopic ellipsometry in its total internal reflection mode (TIRE) is a combination of spectroscopic ellipsometry (SE) and SPR. This offers sensitive detection of binding between a ligand and its receptor, and gives potential solutions to the membrane deposition issues by Langmuir-Schaefer (LS) deposition. Therefore, TIRE enables the study of natively derived membranes in addition to synthetic lipid environments. The aim of this research was to develop the method of TIRE by focusing on the analysis of two distinct types of biological processes: model I tested protein: lipid interactions via amyloid fibrils at natively derived membrane from the neuronal cell line SH-SY5Y; and model II tested protein: protein interactions involved in the targeting and binding of molecular chaperones to cognate receptors, using natively derived chloroplast (CP) membranes. Results of Model I demonstrated how short amyloid fibrils can bring about a toxic gain of function by increased membrane disruption, and Model II showed specific chaperone binding to cognate receptors, providing evidence that there are two predominant chaperone receptors to reside at the outer CP membrane. Together the results demonstrate that TIRE can be used with natively derived membranes to obtain biologically relevant information. The importance of studying membrane proteins is highlighted by the fact that nearly half of the top-selling drugs target membrane proteins, and organelles as potential therapeutic targets. Therefore this research will have a direct impact on the development of new therapeutics and our understanding of disease.
APA, Harvard, Vancouver, ISO, and other styles
27

Oliveira, Henrique Rodrigues. "Desenvolvimento de um método para montagem do sistema osso-prótese em modelos computacionais da artroplastia total do joelho." reponame:Repositório Institucional da UFSC, 2014. https://repositorio.ufsc.br/xmlui/handle/123456789/129328.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2014.
Made available in DSpace on 2015-02-05T20:57:41Z (GMT). No. of bitstreams: 1 331663.pdf: 14347462 bytes, checksum: 2821868a775b30b34c0063f9f24fdbe4 (MD5) Previous issue date: 2014
Desde a primeira artroplastia do joelho bem sucedida, em 1861, vários estudos vêm ajudando engenheiros e ortopedistas na melhoria das técnicas cirúrgicas e no projeto de instrumentos e implantes. Neste contexto, este trabalho vem contribuir com o desenvolvimento de um método que oriente a construção e o alinhamento de um modelo computacional (ossos-próteses) para estudos comparativos da articulação do joelho após uma cirurgia de Artroplastia Total do Joelho (ATJ). O método, quando aplicado na construção do modelo, atende às necessidades de cirurgiões e engenheiros ao fornecer uma ferramenta capaz de simular, mensurar e avaliar precisamente (quando comparada aos métodos experimentais) parâmetros biomecânicos e, assim, facilitar o desenvolvimento das técnicas cirúrgicas e do projeto de próteses de ATJ. O trabalho engloba todos os tecidos ósseos que compõem os membros inferiores e os tecidos moles mais atuantes na articulação patelofemoral: o ligamento patelar, o tendão patelar e o músculo quadríceps, bem como os componentes protéticos de ATJ. Além do método para a construção e o alinhamento da montagem ossos-próteses parametrizada, de acordo com um procolo cirúrgico de ATJ, o trabalho aborda, em paralelo ao método, a modelagem paramétrica do conjunto de implantes do tipo Movimento Guiado. Como forma de demonstrar algumas aplicações do método desenvolvido, foram realizados dois estudos de caso. O primeiro estudo compara o posicionamento do componente femoral com relação ao fêmur após dois protocolos cirúrgicos diferentes de ATJ. O segundo, já utilizando o modelo de corpos rígidos, faz avaliação estática das forças do contato patelofemoral em seis ângulos diferentes de flexão, reproduzindo um agachamento.

Abstract : Since the pioneering knee arthroplasty has proven to be successful in 1861, a number of studies have been helping engineers and orthopaedists in order to improve surgical techniques and the design of devices and prosthesis. This paper aims to contribute to the development of a method which will guide the construction and alignment of a computational model (bone-prosthesis) targeting a comparative study after a total knee arthroplasty (TKA). This method, once applied in the model construction, is supposed to fulfill the needs of surgeons and engineers providing a tool capable of simulate, measure and evaluate more accurately (when compared to experimental methods) the biomechanical parameters in question, facilitating the development of surgical techniques, as well as the design of TKA prostheses. The applied method encompasses not only all lower limbs bone tissues, but also the patellofemoral joint soft tissues: patellar ligament, patellar tendon and quadriceps muscle, along with guide motion TKA prostheses components. Besides the method of parametric construction and alignment of bone-prosthesis assembly, in accordance with a TKA surgical protocol, this work proposed also, in parallel to the method, a parametric modeling to TKA prosthesis, of guide motion model. As a way to demonstrate some of the applications of the method being developed, two case studies were carried out. The first case compares the position of the femoral component relative to the femur after two different surgical protocols in TKA. The second case uses the rigid body model in order to evaluate statically the patellofemoral contact force considering six different flexion angles, replicating the movement of squatting.
APA, Harvard, Vancouver, ISO, and other styles
28

Hayacibara, Roberto Masayuki. "Avaliação da precisão de metodos utilizados na determinação do desajuste das bases de protese total." [s.n.], 2001. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289953.

Full text
Abstract:
Orientadores : Saide Sarckis Domitti, Simonides Consani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-28T03:49:16Z (GMT). No. of bitstreams: 1 Hayacibara_RobertoMasayuki_M.pdf: 2978473 bytes, checksum: deedb6107fb0c5076942b5ad9d4ad29b (MD5) Previous issue date: 2001
Resumo: O objetivo deste trabalho foi avaliar a precisão de dois métodos utilizados na determinação do desajuste das bases de prótese total, confeccionadas com resina acrílica ativada termicamente. Foram obtidos 10 modelos em gesso pedra a partir de um molde de silicone representando uma arcada superior desdentada normal. Sobre os modelos foram confeccionadas as bases de pro:va, incluídas em mufla pela técnica de rotina com polimerização da resina acrílica em banho de água aquecida a 74 :f:2°C por 9 horas. Após esfriamento das muflas em temperatura ambiente, as bases de prótese foram removidas, limpas e acabadas. Em cada conjunto modelo-base de prótese foram demarcadas três linhas transversais (anterior, médio e posterior) e em cada linha foram marcados 5 pontos (fundo de sulco vestibular esquerdo e direito, crista do rebordo esquerdo e direito e linha mediana) onde foram feitas as mensurações. Os métodos estudados na verificação da desadaptação foram: A- interposição de silicona por condensação entre a base e o modelo e a aferição com paquímetro digital modificado; B- após fixação da base no modelo com adesivo, três cortes transversais foram efetuados e as mensurações feitas com microscópio comparador linear. Os dados foram submetidos a Análise de Variância e ao teste de Tukey (5% de significância) que mostraram que o método da medição linear com microscópio comparador foi mais preciso que o método da interposição de silicona, revelando desadaptação com valores estatisticamente menor e significantes, quando foram considerados os fatores método, região e pontos estudados
Abstract: The aim of this study was to evaluate the accuracy of two measurement methods used for the detennination of the adaptation and stability of denture bases made of thermopolymerizing acrilic resin. One rubber mold was used to produce ten identical maxillary edentulous casts in dental stone. Ten denture bases were included into flasks and processed by the conventional method of polymerization (thennostatically controlled water bath for 9 hours at 74 :t2°C) above the dental casts. After cooling at room temperature, the denture bases were removed ITom the flasks, cleaned and trimmed. In each cast with the denture in place, three transversallines settled in the anterior, medial and posterior regions were demarcated, and in each line the space between the base and the cast was measured at 5 reference points (left and right sulcus depth, left and right ridge crest and midpalatal points). Two methods were used: A- interposition of an impression material (silicone rubber) and measurement of its thickness using a modified caliper; B- after fixation of the bases into the casts with adhesive, they were transversely seccioned at the reference lines and read in a linear comparator microscope. AlI data were analysed by ANOV A and Tukey test (5%), and it was concluded that the analyses done by using microscope were more accurate than the interposition of the impression material, revealing for the former method, statistically significant low values, considering methods, regions and points studied.
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
29

Silva, Ana Lúcia Pereira Nascimento da. "Morfoanatomia e teores de nutrientes em gemas de pereira." Universidade Federal de Pelotas, 2012. http://repositorio.ufpel.edu.br/handle/ri/1990.

Full text
Abstract:
Made available in DSpace on 2014-08-20T13:59:05Z (GMT). No. of bitstreams: 1 tese_ana_lucia_pereira_nascimento_da_silva.pdf: 476500 bytes, checksum: c7a8292c6edf7e5b557d8a617acd653a (MD5) Previous issue date: 2012-09-28
The pear crop in southern Brazil emerges as a consistent alternative to the diversification of temperate fruit. However, temperature variations influence the physiological processes involved in internal input and output dormancy that may be connected to the anatomy, physiology and metabolism of the plant. Therefore, this study aimed to evaluate the characteristics and the possible involvement morphoanatomic levels of protein, carbohydrate, calcium and iron flower bud abortion in pear cultivar Nijisseik, in southern Brazil. It were determined the numbers of primordia, doubles inflorescences, length, diameter, volume, total carbohydrate content, total protein content, calcium and iron in gems. The number of primordia was higher in the second and the fourth harvest showing sharp reduction from fourth to fifth collection. The first to the second collection was significantly decreased length of gems, with a slight increase which was maintained in the other harvests. The diameter and volume decreased during the collections. The total carbohydrate had variations during the months of collection, a reduction during the month of august with a significant drop until september. A significant increase in protein concentration was determined from august to september, at this time there was an increase in temperature and reduction in hours of cold. The calcium content was reduced during the months from june to august and subsequent increase until september. Iron had a small reduction from june to july and after had increased as the months passed. According to the results, it can be concluded that the greater the number of origins, the greater the number of double inflorescence and the greater the intensity of necrosis. This fact can be considered as one of the first factors to trigger abortion, followed by lack of nutrients. Abortion may be involved with the reduction of total carbohydrate, and a shortage of calcium and also with increased iron in the period of dormancy of the buds. Perhaps the total proteins not have an effective involvement in bud abortion. The bud abortion is not caused by just one factor, but several factors may be interrelated, necessitating the continuation of studies covering the possible causes of this problem.
O cultivo da pereira surge no Sul do Brasil como uma alternativa consistente para a diversificação da fruticultura de clima temperado. No entanto, as variações de temperatura influenciam nos processos fisiológicos internos envolvidos na entrada e saída da endodormência que podem estar ligados à anatomia, fisiologia e metabolismo da planta. Portanto, esta pesquisa teve por objetivo avaliar as características morfoanatômicas e o possível envolvimento dos níveis de proteína, carboidrato, cálcio e ferro no abortamento de gemas florais de pereira, cultivar Nijisseik, no Sul do Brasil. Foram determinados os números de primórdios, de duplas inflorescências, comprimento, diâmetro, volume, teor de carboidrato total, proteína total, cálcio e ferro das gemas. O número de primórdios foi maior da segunda a quarta coleta e apresentou brusca redução da quarta para a quinta coleta. Da primeira para a segunda coleta houve significativa diminuição do comprimento de gemas, ocorrendo leve aumento que se manteve nas demais coletas. O diâmetro e o volume diminuíram no decorrer das coletas. O teor de carboidratos totais teve variações durante os meses de coleta, apresentando redução durante o mês de agosto com expressivo decréscimo até setembro Um incremento significativo de proteína foi observado de agosto a setembro, época em que ocorreu elevação de temperatura e redução nas horas de frio. O teor de cálcio foi reduzido no decorrer dos meses de junho a agosto, posteriormente aumentando até setembro. O ferro apresentou pequena redução do mês de junho para julho, aumentando após conforme o passar dos meses. Os resultados obtidos induzem a concluir que quanto maior o número de primórdios, maior o número de dupla inflorescência e maior a intensidade de necrose. Este fato pode ser considerado como um dos primeiros fatores a desencadear o abortamento, seguido pela falta de nutrientes. O abortamento pode estar envolvido com a redução do teor de carboidratos totais, aliado a escassez de cálcio e ao aumento do ferro no período de dormência das gemas. As proteínas totais provavelmente não tenham um efetivo envolvimento no abortamento de gemas. O abortamento de gemas não é causado apenas por um fator, mas sim por vários fatores que podem estar interligados, sendo necessária a continuação de estudos abrangendo as possíveis causas deste problema.
APA, Harvard, Vancouver, ISO, and other styles
30

Akhzari, Davoud, and Mohammad Pessarakli. "Effect of Drought Stress on Total Protein, Essential Oil Content, and Physiological Traits of Levisticum Officinale Koch." Taylor & Francis, 2015. http://hdl.handle.net/10150/615121.

Full text
Abstract:
Levisticum officinale Koch is one of the most important plants producing essential oil. An experiment was conducted to determine the effect of drought stress on growth, total protein and essential oil content of Levisticum officinale. The experiment was conducted in a greenhouse, in a completely randomized design using 5 replications. Aridity levels of field capacity irrigation (as control), −0.6 and −1.0 MPa were applied. There was significant effect of aridity on leaf area in Levisticum officinale. The highest leaf area values were found in the lowest aridity (FC) level. The root weight and root length in the −0.6 MPa aridity level were more than that of the control aridity level, but, shoot height and shoot weight were highest in the control treatment. Total soluble protein contents under −0.6 MPa drought stress was numerically lower than that in the control treatment, but statistically there was no significant difference between protein contents in the −0.6 MPa and the control treatment. Compared to the control treatment, total soluble protein contents of Levisticum officinale were significantly decreased in the −1.0 MPa drought treatment. Essential oil content of Levisticum officinale was significantly increased in the −0.6 MPa drought treatment compared to the control. Compared to control treatment, there was a significant reduction found in essential oil content of Levisticum officinale in the −1.0 MPa aridity treatment. The results suggest that in the drought levels between −0.6 to −1.0 MPa, Levisticum officinale could be used for arid and semi-arid lands economical use.
APA, Harvard, Vancouver, ISO, and other styles
31

Berretta, Giacomo. "Total synthesis and semi-synthesis of lipid and protein components of Mycobacterium tuberculosis." Thesis, University of Strathclyde, 2011. http://oleg.lib.strath.ac.uk:80/R/?func=dbin-jump-full&object_id=15583.

Full text
APA, Harvard, Vancouver, ISO, and other styles
32

Ricci, Weber Adad [UNESP]. "Disfunção craniomandibular em pacientes desdentados totais com alteração da dimensão vertical. -." Universidade Estadual Paulista (UNESP), 2002. http://hdl.handle.net/11449/97328.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-12-04Bitstream added on 2014-06-13T18:35:08Z : No. of bitstreams: 1 ricci_wa_me_arafo.pdf: 2180921 bytes, checksum: 4653e1da73841781ac765553c9326a77 (MD5)
O presente estudo procurou avaliar a prevalência de sinais e sintomas de disfunção craniomandibular (D.C.M.) em 100 pacientes desdentados totais, portadores de próteses totais duplas, dos quais 58 apresentavam dimensão vertical normal (Grupo 1) e 42 dimensão vertical com alteração (Grupo 2). Os dados foram obtidos a partir de um índice anamnésico simplificado e de exame físico. Após a análise estatística, foi possível observar que: 1. em relação ao índice anamnésico utilizado, a análise estatística mostrou haver associação entre a dimensão vertical e os sintomas de D.C.M. (p=0,016); 2. quanto ao número de regiões sensíveis à palpação muscular, foi constatada uma associação estatisticamente significante com a dimensão vertical (p=0,014); 3. quando avaliados os grupos musculares isoladamente, apenas a palpação intraoral do músculo pterigóideo lateral apresentou associação estatisticamente significante com a dimensão vertical (p=0,05). Conclui-se, por meio deste estudo, que existe uma evidência de associação entre a dimensão vertical e os sinais e sintomas de D.C.M. considerando-se a metodologia empregada e a população estudada.
The present study evaluated the prevalence of signs and symptoms of temporomandibular disorders in 100 patients wearing complete upper and lower dentures, 58 with normal vertical dimension (Group 1) and 42 with altered vertical dimension (Group 2). The data were obtained utilizing a simplified anamnestic index and of physical exam. After the statistical analysis, it was possible to conclude that: 1. there was a significant correlation between the vertical dimension and the symptoms of temporomandibular disorders, when utilizing the anamnestic index (p=0,016); 2. there was a significant correlation between the vertical dimension and the number of tenderness sites during muscle palpation (p=0,014); 3. when appraised the muscular groups separately, just the tenderness to the intra-oral palpation of the lateral pterygoid muscle showed a statistically significant correlation with the vertical dimension (p=0,05). It could be concluded that there was an association between the vertical dimension and the signs and symptoms of temporomandibular disorders, for this sub population that has been analysed.
APA, Harvard, Vancouver, ISO, and other styles
33

Consani, Rafael Leonardo Xediek 1974. "Efeito do dispositivo RS de contensão, sobre a alteração dimensional das bases de protese total superior." [s.n.], 2000. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289942.

Full text
Abstract:
Orientador: Saide Sarckis Domitti
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-27T09:40:54Z (GMT). No. of bitstreams: 1 Consani_RafaelLeonardoXediek_M.pdf: 5078942 bytes, checksum: 2b86e6de317dfb726f032a50b49bdb9d (MD5) Previous issue date: 2000
Resumo: Este trabalho verificou a adaptação das bases de prótese total superior, confeccionadas com resina acrílica termicamente ativada Clássico, sob a influência das variáveis prensagem e polimerização. Foram confeccionados quarenta modelos em gesso pedra, e os conjuntos modelo-base de cera foram divididos em quatro grupos de dez elementos e incluídos em muflas pela técnica de rotina, recebendo os tratamentos: Grupo 1- prensagem da resina e polimerização imediata em banho de água aquecida a 74°C por nove horas; Grupo 2- prensagem da resina acrílica e polimerização após seis horas, em banho de água aquecida a 74°C por nove horas; Grupo 3- prensagem da resina acrílica, utilização do dispositivo RS de contensão e polimerização imediata em banho de água aquecida a 74°C por nove horas; Grupo 4­prensagem da resina acrílica, utilização do dispositivo RS de contensão e polimerização após seis horas, em banho de água aquecida a 74°C por nove horas. As bases de resina foram fixadas nos modelos com adesivo. Foram efetuados três cortes transversais, correspondentes à distal dos caninos (A), mesial dos primeiros molares (B) e região palatina posterior (C). O desajuste foi verificado com microscópio comparador (Leitz), em cinco pontos referenciais para cada corte. Os dados obtidos foram submetidos à análise estatística e ao teste de Tukey (5%). O dispositivo RS de contensão produziu níveis médios de adaptação (0,168 mm) com diferença estatística significativa (p<0,05) quando comparado com a prensagem convencional (0,215 mm), independente dos demais fatores.O dispositivo RS de contensão produziu níveis médios de adaptação (imediata = 0,173 mm e seis horas = 0,164 mm) com diferença estatística significativa (p<0,05) quando comparado com a prensagem convencional (imediata= 0,213 mm e seis horas= 0,216 mm). No fator corte, o dispositivo RS de contensão produziu valores (A = 0,140 mm, B= 0,183 mm e C= 0,256 mm) com diferença estatística significativa (p<0,05) quando comparado com a prensagem convencional (A= 0,151mm, B= 0,207 mm e C= 0,286 mm). Dentro do fator corte, a polimerização imediata produziu valores (A= 0,140 mm, B= 0,183 mm e C= 0,256 mm) sem diferença estatística significativa (p>0,05) quando comparada com a após seis horas (A= 0,193 mm, B= 0,187 mm e C= 0,244 mm). Independente dos demais fatores, os cortes A (0,140 mm), B (0,185 mm) e C (0,250 mm) foram diferentes estatisticamente entre si (p<0,05)
Abstract: The purpose of this study was to verify the denture base adaptation, made with Clássico heat-cured acrylic resin influenced by packing (conventional and RS tension system) and polymerization time (immediate and after 6 hours) variables. Forty stone plaster-acrylic resin base sets were randomly assigned in 4 groups of 10 elements and inc1uded in metallic frasks by routine technique, in order to receive the following experimental treatments: Group 1- acrylic resin packing and immediate polymerization in heated water at 74°C during 9 hours. Group 2- acrylic resin packing and polymerization after 6 hours in heated water at 74°C during 9 hours. Group 3­acrylic resin packing using RS tension system and immediate polymerization in heated water at 74°C during 9 hours. Group 4- acrylic resin packing using RS contension system and polymerization after 6 hours in heated water at 74°C during 9 hours The resin bases were fixed on stone casts with instantaneous adhesive, and transversally cuts were made in the corresponding regions to distal of bicuspids (A), mesial of the first molars (B), and posterior palatal region (C). The dimensional alteration between acrylic resin base and stone plaster was verified with a comparator microscope at 5 referential points to each kind of cut. The data submitted to ANOV A and Turkey's test at 5% of significance level showed that the RS tension system produced better adaptation level (0.168 mm) with statistical significance (p<.05) when compared to conventional packing (0.215 mm), independently of other factors. For polymerization time, the RS tension system produced better adaptation level (immediate 0.173 mm and after 6 hours 0.164 mm) with statistical significance (p<.05) when compared to conventional packing (immediate 0.213 mm and after 6 hours 0.216 mm). In the cuts, the RS tension system produced values (A= 0.129 mm, B= 0.162 mm, and C= 0.214 mm) with statistical difference (p<.05) when compared to conventional packing (A= 0.151 mm, B= 0.207 mm, and C= 0.286 mm). The immediate cure showed values (A= 0.140 mm, B= 0.183 mm, and C= 0.256 mm) with no statistical difference (p>.05) when compared to those after 6 hours (A= 0.139 mm, B= 0.187 mm, and C= 0.244 mm). Independently ofthe other factors, the A (0.140 mm), B (0.185 mm), and C (0.250 mm) cuts showed values with significative statistical difference
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
34

Almeida, Maria Helena Waack de. "Efeito da combinação de gessos de inclusão sobre a adaptação das bases de protese total superior." [s.n.], 2001. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289955.

Full text
Abstract:
Orientadores : Saide Sarckis Domitti, Simonides Consani
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-28T05:33:00Z (GMT). No. of bitstreams: 1 Almeida_MariaHelenaWaackde_D.pdf: 5508767 bytes, checksum: b03c3c13c9774dfa80be1f7537d1c28d (MD5) Previous issue date: 2001
Resumo: O objetivo desta pesquisa foi verificar os efeitos da combinação de gessos de inclusão na adaptação das bases de prótese total superior, confeccionadas com resina acrílica ativada termicamente, polimerizadas de acordo com os seguintes ciclos: convencional, calor seco e energia de microondas. Foram confeccionados quarenta e cinco modelos padrões em gesso pedra, a partir de um molde de borracha representando uma arcada superior desdentada. Sobre os modelos foram confeccionadas quarenta e cinco bases de prova, divididas aleatoriamente em três grupos de quinze elementos cada, baseados no tipo do gesso utilizado durante a fase de inclusão dos modelos. No Grupo l, as bases de prova foram incluídas em mufla pela técnica convencional, utilizando-se gesso comum e pedra. No Grupo lI, utilizando-se gesso comum e especial, e no Grupo III, gesso pedra e especial. Cada Grupo foi subdividido em três subgrupos, de acordo com o ciclo de polimerização ao qual as amostras foram submetidas: Subgrupo 1: polimerização através do ciclo convencional (74+2°C por 9 horas); Subgrupo 2: polimerização por calor seco (74+2°C por 9 horas); e Subgrupo 3: polimerização através de energia de microondas (900 W por 3 minutos). A seguir, as bases em resina foram fixadas em seus respectivos modelos com adesivo instantâneo. O conjunto base de prótese-modelo de gesso foi posicionado, fixado e seccionado em aparelho específico onde foram executados três cortes látero-Iaterais: A (anterior), B (médio) e C (posterior). A alteração dimensional ocorrida na resina acrílica foi avaliada por meio de um microscópio comparador, em cinco pontos referenciais. Os resultados numéricos foram submetidos à análise de 1 variância e ao teste de Tukey (5%). Concluiu-se que, independente dos demais fatores, o ciclo convencional mostrou o maior desajuste das bases de prótese em relação aos modelos. Quando o tipo de inclusão foi analisado em relação ao fator ciclo de polimerização, verificamos que as inclusões Comum/Especial e Pedra/Especial não apresentaram valores com diferença estatística significativa. Na inclusão Comum/Pedra o ciclo convencional apresentou o maior desajuste. Quando o fator corte foi analisado em função do ciclo de polimerização, notamos que no corte A, o ciclo convencional apresentou o maior desajuste. Quando os cortes foram analisados independente de outros fatores, houve diferença estatística significativa entre eles. O maior desajuste ocorreu no corte C. Quando os cortes foram analisados em relação ao tipo de inclusão independente de outros fatores, verificamos que nas inclusões Comum/Especial e Pedra/Especial, o maior desajuste ocorreu no corte C. Quando o tipo de inclusão foi observado independente de outros fatores, verificamos que a inclusão Comum/Pedra apresentou o menor desajuste
Abstract: he purpose of this study was to verify the effects of the combination of inclusion plaster in the adaptation of upper denture bases, made with heat-cured acrylic resin, ocurred under the influence of three cycles of polymerization: conventional, by dry heat and with microwave energy. Forty-five master casts were made in stone plaster from a rubber cast representing upper nondental arch. The forty-five experimental bases were made on the casts which were divided at randon into three groups of fifteen elements, based on the kind of plaster used during the inclusion phase of the casts. The casts with the experimental bases from Group I were included in flask by conventional technique, using commum plaster and stone. In the Group II, using commum plaster and special, and the Group II stone plaster and special. Each group was subdivided into three subgroups, according the polymerization cycle to which the casts were submitted: Subgroup 1: polymerization through the conventional cycle (74 + 2°e for nine hours). Subgroup 2: polymerization by dry heat (74 + 2° e for nine hours) and Subgroup 3: polymerization in Microwave Oven (900 W for 3 minutes). Next, the bases in resin were fixed on their casts with instantaneous adhesive. The plaster model - prosthesis bases set was positined, fixed and cut on an especific instrument, three lateral plane cuts were made: A (anterior), B (median) and e (posterior). The occurred dimensional alteration on the acrylic resin was evaluated with a comparator microscope in five referential points. The numerical results were submitted to a variance analysis and the Tukey Test (5%). It was concluded that, independent of other factors, the conventional cycle showed the biggest disadjustment of the denture bases in relation to the casts. When the kind of inclusion was analysed in relation to the cycle fa cto r of polymerization, it was verified that the Commum/Special and Stone/Special inclusions did not show statistic significative difference. In the Commum/Stone inclusion the conventional cycle showed the biggest disadjustment. When the cut factor was analysed in relation to the polymerization cycle, it was verified that in the A cut, the conventional cycle showed the biggest disadjustment. When the cuts were analysed independent of other factors, there was significative statistic difference among them. The biggest disadjustment occurred in the C cut. When the cuts were analysed in relation to the kind of inclusion independent of other factors, it was verified that in the Commum/Special and Stone/Special inclusions, the biggest disadjustment occurred in the C cut. When the kind of inclusion was analysed independent of other factors, it was verified that the Commum/Stone inclusion showed the smallest disadjustment
Doutorado
Protese
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
35

Consani, Rafael Leonardo Xediek 1974. "Movimentação linear de dentes em protese total superior sob influencia dos tipos de prensagem e desinclusão." [s.n.], 2002. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289941.

Full text
Abstract:
Orientador : Saide Sarckis Domitti
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-01T21:16:24Z (GMT). No. of bitstreams: 1 Consani_RafaelLeonardoXediek_D.pdf: 8126101 bytes, checksum: cd80ac9be45431a4717330a4c63fb7d8 (MD5) Previous issue date: 2002
Resumo: O propósito deste estudo foi verificar a movimentação linear dos dentes em prótese total superior, confeccionada com resina acrílica ativada termicamente clássico, polimerizada em água a 74°C por 9 horas, após 12 horas da prensagem final, sob a influência do tipo de prensagem (convencional e RS) e da desinclusão (esfiiamento em água e em água mais bancada por 3 horas). Quarenta conjuntos modelo-base de prova de cera, com dentes artificiais, foram separados aleatoriamente em quatro grupos de dez conjuntos e incluídos em muflas metálicas pela técnica de rotina, a fim de receber os tratamentos experimentais: Grupo 1- prensagem convencional, polimerização em água a 74°C por 9 horas, iniciada após 12 horas da prensagem final e desinclusão após esfiiamento em água. Grupo 2- prensagem convencional, polimerização em água a 74°C por 9 horas, iniciada após 12 horas da prensagem final e desinclusão após esfiiamento em água e bancada por 3 horas. Grupo 3- prensagem RS, polimerização em água a 74°C por 9 horas, iniciada após 12 horas da prensagem final e desinclusão após esfiiamento em água. Grupo 4- prensagem RS, polimerização em água a 74°C por 9 horas, iniciada após 12 horas da prensagem final e desinclusão após esfiiamento em água e bancada por 3 horas. As distâncias I-I, PM-PM, M-M, ID-MD e lEME foram mensuradas antes e depois da polimerização da base, com microscópio comparador linear (Olympus), com precisão de 0,0005 mm. Os resultados submetidos à análise de variância e ao teste de Tukey em nível de 5% de significância mostraram que: a) Fator polimerização: não houve diferença estatística significativa nas distâncias transversais I-I, PM-PM e M M em todas interações; nas distâncias ântero-posteriores ID-MD e IE-ME na prensagem convencional com desinclusão após esfiiamento em água; e na prensagem RS com desinclusão após esfiiamento em água mais bancada por 3 horas. Houve diferença estatística significativa nos valores das distâncias ID-MD e IE-ME na prensagem convencional com desinclusão após esfriamento em água mais bancada por 3 horas e na prensagem RS com esfriamento em água. b) Fator prensagem: as distâncias I-I, PM-PM e M-M não apresentaram diferença estatística significativa em todas as interações. O mesmo aconteceu nas distâncias ID-MD e IE-ME antes da polimerização com desinclusão após esfriamento em água; após polimerização com desinclusão após esfriamento em água; e antes da polimerização com desinclusão após esfriamento em água mais bancada por 3 horas. Houve diferença estatística significativa nos valores das distâncias ID-MD e IE-ME após polimerização com desinclusão após esfriamento em água mais bancada por 3 horas. c) Fator desinclusão: as distâncias I-I, PM-PM, M-M, ID-MD e IE-ME foram sem diferença estatística significativa em todas as interações
Abstract: The purpose of this study was to verify the linear teeth movement in maxillary denture made with Clássico heat -cured acrylic resin, polymerized in water at 74°C for 9 hours, 12 hours after the detinitive flask closure, and influenced by pressing (conventional and RS) and deflasking (water cooling and water-cooling plus bench for 3 hours). Forty stone casts-wax plate base with teeth were randomly assigned in 4 groups of 10 elements and included in metallic frasks by routine technique, in order to receive the following experimental treatments: Group 1- conventional pressure, polymerization in water at 74°C for 9 hours, starting 12 hours after the detinitive pressure and deflasking after water-cooling. Group 2- conventional pressure, polymerization in water at 74°C for 9 hours, starting 12 hours after the definitive pressure and deflasking after water-cooling and bench for 3 hours. Group 3- RS pressure, polymerization in water at 74°C for 9 hours, starting 12 hours after the definitive pressure and deflasking after water-cooling. Group 4- RS pressure, polymerization in water at 74°C for 9 hours, starting 12 hours after the detinitive pressure and deflasking after water-cooling and bench for 3 hours. The I-I, PM-PM, M-M, RI-RM and LI-LM distances were determined before and after base polymerization, with a linear comparator microscope (Olympus), with tolerance of 0.0005 mm. The data submitted to ANOV A and Turkey's test at 5% of significance leveI showed that: a) Polymerization factor: there was no statistically significant difference in the lI, PM-PM and M-M distances in all interactions. The same was showed in the RI-RM and LI-LM distances in the conventional pressure with deflasking after water-cooling, and in the RS pressure with deflasking after watercooling plus bench for 3 hours. There was statistically significant difference in the RI-RM and LI-LM distance values in the conventional pressure with deflasking afier water-cooling plus bench for 3 hours, and in the RS pressure with deflasking afier water-cooling. b) Pressure factor: the I-I, PM-PM, M-M distances was no statistically significant difference in alI interactions. The same occurred in the RI-RM and LI-LM distances before and afier poIymerization with deflasking afier water-cooIing, and before poIymerization with deflasking afier water-cooIing pIus bench for 3 hours. There was statisticaUy significant difference in the RI-RM and LI-LM distances afier poIymerization with deflasking afier water-cooling pIus bench for 3 hours. c) Deflasking factor: The I-I, PM-PM, M-M, RI-RM and LI-LM distances were no statisticalIy significant difference in alI interactions
Doutorado
Protese Dental
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
36

Ferreira, Daniel Filgueiras. "Avaliação eletromiografica da eficiencia de duas tecnicas de montagem de dentes artificiais em protese total dupla." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289924.

Full text
Abstract:
Orientador: Marcelo Ferraz Mesquita
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T05:56:39Z (GMT). No. of bitstreams: 1 Ferreira_DanielFilgueiras_M.pdf: 1227737 bytes, checksum: 8574e46d80b04a8d94d10a74cac5fef3 (MD5) Previous issue date: 2005
Resumo: O objetivo desta pesquisa foi avaliar eletromiograficamente o padrão de atividade muscular resultante da utilização de duas técnicas de montagem de dentes artificiais para obtenção de equilíbrio em prótese total dupla. Vinte e quatro pacientes totalmente edêntulos, livres de sinais e sintomas de Desordem Temporomandibular (DTM) com no mínimo cinco anos de uso de próteses totais, foram separados em dois grupos de 12 pacientes: (G1 e G2). Para o G1, utilizou-se a técnica Convencional, onde o equilíbrio foi obtido através de contatos interferentes entre dentes artificiais. Para o G2, utilizou-se a técnica das Rampas Posteriores de Nóbilo, que proporciona equilíbrio através de contatos deslizantes entre a superfície das rampas. O padrão de atividade muscular foi mensurado através da atividade eletromiográfica (EMG) dos músculos temporais porção anterior e masseteres nas posições de repouso (R) e na contração isométrica em máxima intercuspidação (CIMI), avaliado em quatro tempos: T0 - instalação; T1 - 1o mês; T2 - 2o meses; T3 - 3o meses de uso das próteses. Foi utilizado o eletromiógrafo Myosystem I® (Prosecon Ltda, Uberlândia, MG, Brasil) e o sinal eletromiográfico condicionado através de filtro digital passa faixa e analisado em relação RMS (Root Mean Square). Em ambos os grupos, observou-se pequenas alterações nos valores da atividade EMG para os músculos temporais anteriores e masseteres na posição de R. Na posição de CIMI, no G1 os músculos temporais anteriores apresentaram valores finais menores que os iniciais, e situação inversa foi observada para os masseteres, com valores finais maiores que os iniciais; no G2 observou-se inversão dos valores para os músculos temporais anteriores e aumento para os masseteres com ligeiro equilíbrio no terceiro mês de avaliação. O teste Wilcoxon-Mann-Whitney entre as técnicas e o de Friedman nos tempos avaliados não mostraram diferenças estatísticas significativas (p<0.05). Conclui-se que as técnicas estudadas clinicamente não apresentaram diferença entre si, e que as avaliações nos tempos não proporcionaram o equilíbrio dos músculos mastigatórios estudados. Dessa forma, ambas técnicas podem ser utilizadas com performances clínicas semelhantes
Abstract: The aim of this study was to evaluate by the electromyography muscular activity pattern resulting of two prosthetic teeth arrangement techniques that promote balance in double complete dentures. Twenty-four subjects totally edentulous, free from signs and symptoms of TMJ disorders and with at least five years complete dentures use were divided in two groups of 12 subjects: G1 and G2. In the Group 1, the Conventional technique was used and the interference contacts between artificial teeth were responsible for the balance. In the Group 2, the Nóbilo's Balancing Ramps technique, slippery contacts between ramps surfaces provided balance. The muscular activity pattern was measured by electromyographic (EMG) activity of anterior temporal and masseter muscles in the mandibular rest (R) and maximal biting in the intercuspal position (CIMI) at four times: T0 - installation; T1 - 1st month; T2 - 2nd month; T3 - 3rd month of prostheses use. The electromyographic sign was collected with Myosystem I® conditioned through of digital filter pass band and analyzed in relation to RMS (Root Mean Square). In both groups, in the mandibular rest of the anterior temporal and masseter muscles was observed small alterations in the EMG activity values. In CIMI position, in the Group 1, anterior temporal muscles showed final values smaller than the initial, differently of masseter muscles that showed final values greater than the initial; in the Group 2 inversion values were observed in the temporal muscles and increase in the masseter with light balance in the third month evaluation. Wilcoxon-Mann-Whitney test between the techniques and the Friedman test in the evaluated times did not show significant statistical differences (p<0.05). The techniques clinically studied did not show differences between themselves and the times evaluation did not provide balance in the masticatory muscles studied. In this way, both techniques can be used with similar clinic performance
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
37

Joia, Fabio Alves. "Movimentação dental linear em protese total superior e inferior em função de diferentes tecnicas de inclusão." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290538.

Full text
Abstract:
Orientador: Celia Marisa Rizzatti Barbosa
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-05T02:25:21Z (GMT). No. of bitstreams: 1 Joia_FabioAlves_M.pdf: 5977969 bytes, checksum: e66707336fade444f0c8a18dedfa11c1 (MD5) Previous issue date: 2005
Resumo: O presente estudo avaliou a movimentação dental linear em prótese total superior e inferior em função de diferentes técnicas de inclusão. Quarenta pares do conjunto modelo-base de prova em cera, com os dentes artificiais montados, das arcadas superior e inferior, foram distribuídos ao acaso em quatro grupos de 10 pares cada, recebendo os seguintes tratamentos: Grupo A ¿ Inclusão em mufla monomaxilar de Cloreto de Polivinila (PVC) com muralha de gesso Tipo III; Grupo B ¿ Inclusão em mufla de PVC bimaxilar com muralha de silicone para laboratório, sem retenção nos dentes artificiais; Grupo C ¿ Inclusão em mufla de PVC bimaxilar com muralha de gesso Tipo III; Grupo D ¿ Inclusão em mufla de PVC bimaxilar com muralha de silicone para laboratório, com retenção nos dentes artificiais. Nos quatro grupos a resina acrílica utilizada na polimerização das próteses foi a resina termicamente ativada por energia de microondas, sendo o ciclo de polimerização realizado com um tempo de 20 minutos a 20% da potência, mais um ciclo de 5 minutos a 60% da potência do forno de microondas de 960 W de potência máxima, sem intervalo entre os ciclos. Sete distâncias em arco, duas distâncias diagonais e três distâncias transversais foram mensuradas, por um único avaliador, antes da inclusão e após a polimerização da base, com auxílio do microscópio mensurador linear (Olympus STM), com precisão de 0,0005 milímetro. Os dados obtidos foram submetidos à análise estatística pelo método não paramétrico de Kruskal-Wallis (p<0,05) e pelas comparações múltiplas pelo método de Dunn. A análise demonstrou diferenças estatisticamente significantes para três medidas em arco, as duas distâncias diagonais e as três distâncias transversais, entre o grupo de inclusão monomaxilar (A) e pelo menos um grupo de inclusão bimaxilar (B, C ou D), sendo os menores valores de alterações dentais lineares encontrados, em sua maioria, nos grupos de inclusão bimaxilar com muralha de silicone (B e D). Diante das condições experimentais presentes, foi possível concluir que o método de inclusão bimaxilar é mais viável quando associado ao uso da muralha de silicone com ou sem retenções nos dentes artificiais, em relação à inclusão monomaxilar
Abstract: The present study evaluated linear dental movement in maxillary and mandibular complete denture using different flasking technics. Forty pairs of the joint model-wax base, of maxillary and mandibular arches, with mounted artificial teeth, had been randomized distributed into four groups of 10 pairs each, receiving the following treatments: GA: invested in conventional flask, in a total gypsum environment; GB: invested in special flask for simultaneous polymerization using silicone and gypsum base; GC: invested in special flask for simultaneous polymerization of maxillary and mandibular prostheses in a total gypsum environment; GD: invested in special flask for simultaneous polymerization using silicone, gypsum base, and retentions on artificial teeth. The prostheses were processed with heat-polymerized acrylic resin for microwaves energy polymerization, during 20 minutes at 20% of the power, plus an additional cycle of 5 minutes at 60% of the power, of a microwave oven of 960W maximum power, without interval between the cycles. Seven arch distances, two diagonal distances and three transversal distances had been measured, by an only appraiser, before flasking and after processing, with aid of a measuring microscope (Olympus, model STM), with 0.0005 millimeter precision. Data had been statistically analyzed by Kruskal-Wallis test (p<0.05) and Dunn test. It demonstrated statistically significant differences in three arch distances, two diagonal distances and three transversal distances, between group A (conventional flask) and at least one group of bimaxilar flask (B, C or D), with the lesser values of linear dental alterations been found, in its majority, at bimaxilar flask with silicone and gypsum base groups (B and D). Ahead of the experimental conditions gifts, it was possible to conclude that bimaxilar flasking method is more viable when associate to the use of the silicone and gypsum base with or without retention in artificial teeth, when compared with conventional flasking procedure
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
38

Lopes, Michelle Cristina. "Efeito do conteudo de monomero na proporção monomero-polimero no deslocamento dental em protese total superior." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288554.

Full text
Abstract:
Orientador: Rafael Leonardo Xediek Consani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-14T14:57:31Z (GMT). No. of bitstreams: 1 Lopes_MichelleCristina_M.pdf: 433524 bytes, checksum: 7d01d350cce34280c9bae82f9e766739 (MD5) Previous issue date: 2009
Resumo: O propósito neste estudo foi verificar a movimentação linear de dentes em prótese total superior confeccionada em resina acrílica, com conteúdo de monômero na proporção monômero-polímero indicado pelo fabricante, com 25% de excesso e com 25% a menos, nas técnicas de polimerização convencional e por microondas. Foram confeccionados 30 modelos em gesso pedra tipo III, a partir de um molde de silicone, representando uma arcada maxilar desdentada com rebordo normal. As bases de prova foram confeccionadas com espessura de ±2,5mm e os planos de orientação em cera, com 1cm de altura posterior e 2 cm de altura anterior. O modelo de gesso com o plano de orientação em cera foi fixado no ramo superior do articulador semi-ajustável, com distância intercondilar média, ângulo de Bennet em 15 graus e guia condilar em 30 graus. Em seguida, um modelo de arcada mandibular dentada foi posicionado sobre o plano de cera do modelo superior e fixado na haste inferior do articulador, posicionando o pino incisal em zero. Depois da montagem dos dentes artificiais, o modelo da prótese foi removido do articulador e moldado com silicone. Os dentes foram colocados no molde e sobre eles foi vertida cera rosa liquefeita, até o completo preenchimento do molde. Antes da solidificação da cera, o modelo de gesso foi adaptado no molde e mantido em posição até o completo esfriamento da cera, quando o conjunto modelo de gesso-base de prova com dentes artificiais foi removido do molde. Foram confeccionados pontos referenciais sobre a região mediana da borda incisal dos incisivos centrais, cúspide vestibular dos primeiros pré-molares e cúspide disto-vestibular dos segundos molares, por meio de perfurações para fixação de segmentos de alfinetes metálicos com adesivo instantâneo à base de cianoacrilato. As mensurações foram realizadas nas distâncias transversais entre: incisivos centrais; primeiros pré-molares; e segundos molares, e ântero-posteriores entre: incisivo central direito e molar direito; incisivo central esquerdo e molar esquerdo, com microscópio comparador linear antes da inclusão e depois do acabamento das próteses. Nos grupos com proporção recomendada pelos fabricantes, as próteses foram prensadas convencionalmente. Nos demais grupos, os mesmos procedimentos foram adotados, com exceção da proporção de monômero que foi de 25% a mais ou 25% a menos. Os dados de deslocamento dental foram submetidos à análise de variância e ao teste de Tukey (5%). Não houve diferença estatística entre os grupos com quantidade de monômero recomendada pelo fabricante (grupo controle) e os demais grupos tanto na polimerização convencional como por microondas. A alteração na quantidade de monômero para mais ou para menos em relação à proporção monômero-polímero não influenciou a movimentação dental linear nos sentidos transversal e ântero-posterior.
Abstract: The purpose of the study was to verify the linear displacement of the teeth in complete upper denture made with acrylic resin, with monomer content indicated by the manufacturer, with 25% in excess and 25% less, in the conventional and microwaves polymerization techniques. Thirty casts were made with type III stone plaster, based on silicone mould, representing an edentulous maxillary arch with normal edge. The wax baseplates were manufactured in a ±2.5mm thickness and the wax rims with 10 mm of posterior height and 20 mm of anterior height. The stone cast related with the wax rim was fixed at the top stem of semi-adjustable articulator, adjusting the intercondylar distance in Medium, the angle of Bennet in 15 degrees and the condylar guidance in 30 degrees. A mandibular arch with teeth was placed on the wax rim and fixed on the bottom shaft of the articulator, positioning the incisal pin to zero. After mounting the artificial teeth, the denture was removed from the articulator and impressed with silicone. The teeth were placed in the impression mold and over them it was poured a liquid wax, until the mold filling was completed. Before solidification of the wax, the stone cast mold was adapted in the impression and kept in position until the wax setting. After wax setting, the stone cast- denture with artificial teeth set was removed from the silicone impression. Reference points were fixed over the median region of the incisal edge of central incisors, buccal cusp of the first premolar and distal-buccal cusp of the second molars in drill holes performed for fixation of the metal pin segments with instantaneous adhesive based on cyanoacrylate. The measurements were made in the transverse distances among: central incisors; first premolar; second molar, and anteroposterior among: central right incisor and right molar; central left incisor and left molar, with a linear comparator microscope before and after denture procedure. In the groups with monomer content recommended by the manufacturer, the dentures were conventionally pressed. In the other groups, the same procedures were adopted, with exception of the monomer content that was 25% in excess or 25% less. The dental displacement data were submitted to ANOVA and Tukey's test (5%). There was no statistically significant difference among the groups with the monomer content recommended by the manufacturer and other groups, in both conventional and microwaved activations. To change the content of monomer to more or less in relation to monomer-polymer proportion did not influence the linear displacement of the teeth in transverse or anteroposterior directions.
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
39

Devito, Fábio Stucchi. "Eficácia do uso do Templating na artroplastia total do quadril." Faculdade de Medicina de São José do Rio Preto, 2009. http://bdtd.famerp.br/handle/tede/62.

Full text
Abstract:
Made available in DSpace on 2016-01-26T12:51:22Z (GMT). No. of bitstreams: 1 fabiostuchidevito_tese.pdf: 1050230 bytes, checksum: 52d8e95acef4a4ba2f5e60d301266786 (MD5) Previous issue date: 2009-04-17
Total hip arthroplasty is a surgery with a high success rate, providing pain relief and improvement of the articular mobility. Long-term success is related to the position and orientation of the acetabular and femoral components. Traditional preoperative planning entails radiographic analysis of the pelvis, in which a template is placed on the image, allowing an analysis of the appropriate size of the Exeter cemented prosthesis. Objective: To evaluate the effectiveness of traditional preoperative planning with the use of templating. Patients and Method: Forty-three anteroposterior X-rays were analyzed by three experienced surgeons. The evaluation of each surgeon was compared with the actual prosthesis used in the surgery and also compared with the assessment of the other two surgeons. Cohen's Kappa concordance test and weighted Kappa indexes using quadratic weighting were used for statistical analysis with a confidence interval of 95%. Results: The preoperative evaluations of Surgeons A, B and C were divided into the analysis of the sizes of the acetabular cup, stem and plug of the distal femoral canal. Surgeon A obtained a moderate agreement in relation to the acetabular component and substantial agreements in relation to the stem and plug. Surgeon B had moderate agreement in relation to both the acetabulum and the stem and substantial agreement in relation to the plug. Surgeon C obtained moderate agreement in relation to the analysis of the acetabulum and the plug and substantial agreement for the stem. The intra-observer agreement test demonstrated a prevalence of slight agreement in relation to the acetabulum and substantial agreement in relation to the stem and to the plug. Conclusion: Templating used in preoperative planning proved effective; however, there was a prevalence of slight and moderate agreement in relation to the size of the acetabular component according to the inter- and intra-observer analysis.
A artroplastia total do quadril é uma cirurgia com alto índice de sucesso, atuando no alívio da dor e melhora da mobilidade articular e seu êxito a longo prazo relaciona-se à posição e orientação do componente acetabular e femoral. O planejamento pré-operatório tradicional consiste na análise radiográfica da bacia, na qual será sobreposto um templating , o que permite a análise do tamanho adequado da prótese Exeter cimentada. Objetivo: Avaliar a eficácia do planejamento pré-operatório tradicional pelo uso do templating . Casuística e Método: Quarenta e três radiografias na posição antero-posterior e foram analisadas por três cirurgiões experientes; as avaliações de cada cirurgião foram comparadas com a prótese utilizada na cirurgia e cada resultado comparado com os resultados dos outros dois. Para avaliação, utilizou-se o teste de concordância do Capa de Cohen e do Capa ponderado, com ponderação quadrática e intervalo de confiança de 95%.Resultados: Os resultados pré-operatório encontrados pelo examinadores A, B e C foram divididos como análise do tamanho do acetábulo, haste e plug do canal femoral distal. O cirurgião A obteve em relação ao componente acetabular uma concordância moderada, e em relação à haste e ao plug uma concordância substancial. O cirurgião B apresentou resultado de concordância moderada em relação ao acetábulo e à haste e substancial em relação ao plug. O cirurgião C na análise acetabular e do plug obteve concordância moderada e substancial quanto à haste. O teste de concordância intra-observador apresentou uma prevalência da concordância leve em relação ao acetábulo e substancial em relação à haste e ao plug. Conclusão: O templating utilizado no planejamento pré-operatório mostrou-se eficaz, no entanto, em relação ao tamanho do componente acetabular houve um predomínio de concordância leve e moderada na análise inter e intraobservador.
APA, Harvard, Vancouver, ISO, and other styles
40

Schuldt, Filho Guenther. "Influência dos fatores locais na prevalência da peri-implantite ao redor de implantes pilares de próteses totais fixas." Florianópolis, 2012. http://repositorio.ufsc.br/xmlui/handle/123456789/96205.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia
Made available in DSpace on 2012-10-26T09:48:06Z (GMT). No. of bitstreams: 1 304705.pdf: 13802930 bytes, checksum: e7dccfe8d948661bd94ee0c5e41f1cf9 (MD5)
Objetivo: A proposta deste estudo foi avaliar a influência dos fatores locais na prevalência da peri-implantite em implantes osseointegrados instalados na mandíbula e maxila de pacientes que utilizavam próteses totais implantossuportadas. Materiais e Métodos: Foram examinados 27 pacientes (161 implantes) que apresentavam implantes cilíndricos, conexão do tipo hexágono externo (Conexão, São Paulo, Brasil), radiografias mensuráveis, informações dos prontuários preenchidas adequadamente e próteses totais implantossuportadas aparafusadas. Para este estudo, nenhum dos pacientes havia sido submetido à algum tipo de visita para manutenção da prótese e dos implantes no CEPID. Foram coletadas informações com relação ao sexo, idade, hábitos tabagistas, histórico de doença periodontal e saúde geral do paciente antes e após a instalação dos implantes. Com relação aos implantes, coletaram-se informações referentes às suas características tais como localização, posicionamento, tempo em função, quantidade de mucosa ceratinizada, profundidade de sondagem, índice de sangramento do sulco modificado, tipo de carga, índice de placa modificado, sangramento à sondagem, recessão e distância entre implantes. Com relação à prótese, os dados coletados estavam relacionados à dificuldade de higienização, tipo de pilar utilizado, presença ou não de pilar protético e extensão do cantiléver. Resultados: Dos 161 implantes analisados, 116 (72%) apresentaram-se sem peri-implantite enquanto que 45 (28%) apresentavam a doença. Houve significância estatística (p < 0.05) com relação à localização - implantes instalados na maxila possuem 2.98 vezes mais chances de apresentarem peri-implantite. Assim como os pacientes com idade ? 60 anos tem 3.24 vezes mais chances de apresentarem este tipo de doença. Outra análise com relevância estatística (p < 0.05) foi a de que se não obedecida a distância de no mínimo 3 mm entre implantes, as chances do surgimento da doença aumentam em 2.98 vezes. Não houve relevância estatística em nenhuma das outras análises. Conclusão: Conclui-se que pacientes com idade ? 60 anos possuem maior propensão à peri-implantite assim como implantes instalados na maxila e aqueles com distância entre sim < 3 mm.
Objective: The purpose of this study was to evaluate the influence of local factors in peri-implantis' prevalence in osseointegrated implants installed either on mandible or maxilla of patients using full-arch prostheses. Materials and Methods: There were examined 27 patients (116 implants) that presented cylindric implants with external hex connection (Conexão, São Paulo, Brasil), radiographs, charts filled correctly and screwed full-arch prostheses. For this study, none of the patients attended any follow-up visit until the data collection. There were collected information regarding gender, age, smoking habits, periodontal disease historic and patient's general health before and after implants installation. In relation to the implant, information obtained were about its characteristics, positioning, time in function, bleeding on probing, width of keratinized mucosa, modified sulcus bleeding index, type of loading, modified plaque index, probing depth, recession and distance between implants. Considering full-arch prostheses, the data collected were related with hygiene difficulty, type of abutment, abutment presence or not and cantilever extension. Results: Of the 161 implants analysed, 116 (72%) showed no peri-implantitis whereas 45 (28%) presented signs and symptoms of the disease. There was statistical significance (p < 0.05) regarding implant positioning - implants installed in the maxilla are 2.98 times more likely to develop the disease. As well as patients aged = 60 years old are 3.24 times more likely of presenting peri-implantitis. Another analysis with statistical relevance (p <0.05) was that implants with less than 3mm between them, are 3 times more likely of having peri-implantitis. There was no statistical relevance considering the other analyses. Conclusion: It can be concluded that patients aged = 60 years have more chances of presenting peri-implantitis as well as implants positioned in the maxilla and those installed with distance between them < 3 mm.
APA, Harvard, Vancouver, ISO, and other styles
41

Cook, Larry Jonathan. "Totally Asymmetric Simple Exclusion Processes with Finite Resources." Diss., Virginia Tech, 2009. http://hdl.handle.net/10919/30121.

Full text
Abstract:
In many situations in the world, the amount of resources available for use is limited. This statement is especially true in the cells of living organisms. During the translation process in protein synthesis, ribosomes move along the mRNA strand constructing proteins based on the sequence of codons that form a gene. The totally asymmetric simple exclusion process (TASEP) models well the translation process. However, these genes are constantly competing for ribosomes and other resources in the cell. To see how finite resources and competition affects such a system, we must construct a simple model to account for the limited resources. We consider coupling multiple TASEPs to a finite reservoir of particles where the entry rate of particles into the TASEPs depends on the number of particles left in the reservoir. Starting with a single TASEP connected to the reservoir, we study the system using both Monte Carlo simulations and theoretical approaches. We explore how the average overall density, density profile, and current change as a function of the number of particles initially in the reservoir for various parameters. New features arise not seen in the ordinary TASEP model, even for a single TASEP connected to the pool of particles. These features include a localized shock in the density profile. To explain what is seen in the simulations, we use an appropriately generalized version of a domain wall theory. The dynamics of the TASEPs with finite resources are also studied through the power spectra associated with the total particle occupancy of each TASEP and the reservoir. Again, we find new phenomena not seen in the power spectrum of the ordinary TASEP. For a single constrained TASEP, we find a suppression at low frequencies when compared to the power spectrum of the ordinary TASEP. The severity of this suppression is found to depend on how the entry rate changes with respect to the number of particles in the pool. For two TASEPs of different lengths, we find an enhancement of the power spectrum of the smaller TASEP when compared to the ordinary TASEP's power spectrum. We explain these findings using a linearized Langevin equation. Finally, we model competition between ten genes found in Escherichia coli using a modified version of the TASEP. This modified version includes extended objects and inhomogeneous internal hopping rates. We use the insight gained from the previous studies of finite resources and competition as well as other studies to gain some insight into how competition affects protein production.
Ph. D.
APA, Harvard, Vancouver, ISO, and other styles
42

Yu, Ruixuan Ryan. "Hybrid-Phase Native Chemical Ligation Approaches to Overcome the Limitations of Protein Total Synthesis." The Ohio State University, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=osu1469191712.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Xie, Tian. "Scintillation proximity assay (SPA) measuring p53 DNA binding and total p53 level in human thyroid cancer cell line ARO." Diss., Online access via UMI:, 2007.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
44

Boscato, Noeli. "Movimentação dental linear em protese total superior em função dos materiais de inclusão e metodos de polimerização." [s.n.], 2002. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290321.

Full text
Abstract:
Orientadores : Saide Sarckis Domitti, Simonides Consani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-02T19:35:31Z (GMT). No. of bitstreams: 1 Boscato_Noeli_M.pdf: 1495029 bytes, checksum: c863e45b8ffda144f65c6b53a089e4e9 (MD5) Previous issue date: 2002
Mestrado
APA, Harvard, Vancouver, ISO, and other styles
45

Zampieri, Marinaldo Henrique. "Alteração dimensional da base de protese total superior e inferior, sob influencia da inclusão em mufla dupla." [s.n.], 2008. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288559.

Full text
Abstract:
Orientador: Rafael Leonardo Xediek Consani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-10T13:00:28Z (GMT). No. of bitstreams: 1 Zampieri_MarinaldoHenrique_M.pdf: 729614 bytes, checksum: 67cd861fbbbca6e4ac88c4d28cbc4975 (MD5) Previous issue date: 2008
Resumo: O propósito deste trabalho foi estudar o efeito de muflas metálicas (convencional e mufla dupla experimental SR) e do tempo pós-prensagem (imediato e 6 horas) no nível de adaptação de bases de prótese total superior e inferior confeccionadas com resina acrílica Clássico ativada termicamente. Foramconfeccionados 80 conjuntos modelo de gesso-base de cera distribuídos aleatoriamente em 6 grupos (n=10), de acordo com o tipo de mufla metálica e do tempo pós-prensagem. A resina acrílica foi proporcionada e manipulada de acordo com as instruções do fabricante e prensada na fase plástica com carga inicial de 850 kgf e final de 1.250 kgf em prensa hidráulica de bancada. As bases foram polimerizadas em ciclo de água a 74°C por 9 horas. Depois do esfriamento das muflas até atingir a temperatura ambiente, as bases foram desincluídas, acabadas, fixadas nos respectivos modelos de gesso com adesivo à base de cianoacrilato e seccionados em três secções, correspondentes a distal de caninos (A), mesial de primeiros molares(B) e região palatina posterior(C). Em cada conjunto, o desajuste entre o modelo de gesso e a base de resina foi verificado nos seguintes pontos referenciais: 1- base superior: fundo do sulco vestibular direito e esquerdo, crista do rebordo alveolar direita e esquerda e linha mediana palatina; 2- inferior: fundo do sulco vestibular esquerdo e direito, crista do rebordo alveolar direita e esquerda, e fundo de sulco lingual direito e esquerdo. O desajuste foi verificado com microscópio comparador linear Olympus, com precisão de 0,0005mm. Os dados coletados foram submetidos à análise de variância e ao teste de Tukey (5%). Os resultados mostraram que houve diferença estatística significante entre as secções, onde A apresentou o melhor resultado, C o pior resultado e B demonstrou valor intermediário, para as bases superior e inferior. Na base de prótese superior, os tempos pós-prensagem em cada tipo de região e tipo de mufla mostraram diferença estatística, exceto na região A, para a mufla simples. Na comparação entre tipos de mufla para cada região no tempo imediato houve diferença estatística significante para todas as regiões. No tempo pós-prensagem de 6 horas não houve diferença estatística em todas as comparações. Entre os tipos de região para cada tempo pósprensagem da base inferior, o tempo imediato demonstrou diferença estatística em todas as regiões, quando o tipo de mufla foi comparado. O tempo de espera de 6 horas não mostrou diferença estatística entre as regiões e tipos de muflas
Abstract: The purpose of this work was to study the use of flask closure (conventional metallic flask closure nº5,5 and double SR flask closure.), regarding the adaptation of the prothesis'base (immediate and after six hours) in the upper total prothesis base and also the inferior total prothesis base adaptation. Both prothesis were made of acrylic resin activated by temperature (Classic®). 80 gypsum models were manufactured with wax base randomly distributed in 8 groups (n=10), according to the type of metallic flask closure used and the time that the prothesis remained under pressure (immediate or after six hours). The resin was proportionate and manipulated according to the manufacturer instructions and it was put under pressure in the plastic phase, starting with 850 Kgf until 1250 Kgf utilizing the hydraulic press of workbench. The bases were manufactured and polymerized in water cycle at 74°C for 9 hours. After they reached room temperature, the bases were removed, finished, and replaced in its respective models using cianocrilato adhesive on the base. The models were divided into three sections, corresponding to distal of canines, mesial of first molars and posterior palate region. In each model, the superior and lower maladjustment between the gypsum model and the resin base was verified in the reference points mention above; Superior model: bottom of vestibular sulcus (right and left sides), alveolar crest (right and left sides) and average line of the palate. Lower model: bottom of vestibular sulcus (right and left sides), crest of the edge alveolar crest (right and left sides) and bottom of lingual sulcus (right and left sides). In each section, the maladjustment between the model and resin base was verified with an Olympus comparative linear microscope, with 0,0005mm accuracy. The data were collected and submitted to analysis of variance and to the test of Tukey (5%). The test results demonstrated a significant statistical difference between the sections, where section A showed the best result, C the worst, and B showed an intermediate value, for the lower and upper bases of the prothesis. In the base of the upper prosthesis, the time that the material was under pressure in each region and type of flask closure showed statistical difference, except in region A, for the simple flask closure. In the comparison between types of flask closure for each region in the immediate time showed significant statistical difference for all the regions. There was no statistical difference during the time the material was under pressure (6 hours) for all comparisons. When the types of flask closure were compared regarding region types for each time the lower base was under pressure, the immediate time showed statistical difference in all the regions. There was no statistical difference between the regions and types of flask closure after a period of six hours
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
46

Mendoza, Marin Danny Omar [UNESP]. "Influência da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos de usuários de próteses totais." Universidade Estadual Paulista (UNESP), 2013. http://hdl.handle.net/11449/97330.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-13Bitstream added on 2014-06-13T18:58:06Z : No. of bitstreams: 1 mendozamarin_do_me_arafo.pdf: 1018438 bytes, checksum: 1f8b0462d02af967b5cf054c1dc81a6d (MD5)
Objetivo: O objetivo deste estudo foi avaliar o efeito da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos em usuários de próteses totais por meio de um estudo “cross-over”. Material e Métodos: Cinquenta pacientes desdentados receberam novas próteses totais bimaxilares. Após um período de adaptação, os participantes incluídos no estudo receberam uma sequência de tratamento: protocolo 1- utilização do adesivo para prótese durante os primeiros 15 dias, seguida por não utilização do adesivo os próximos 15 dias; protocolo 2- não utilização do adesivo durante os primeiros 15 dias; seguida por utilização do adesivo os próximos 15 dias. Os resultados foram avaliados após 15 dias de cada sequência de tratamento. Um questionário para avaliar a satisfação dos pacientes e um cinesiógrafo para registrar os movimentos mandibulares e o padrão de movimento da prótese total maxilar durante mastigação foram utilizados. O teste de “Wilcoxon” (α=0,05) e o “t-test” de student para amostras pareadas (α=0,05) foram utilizados para comparar o grau de satisfação dos pacientes e os dados cinesiográficos, respectivamente. Resultados: O adesivo para prótese melhorou significativamente a satisfação geral dos participantes (p<0,001). Os registros cinesiográficos mostraram um aumento significativo (1,7mm) no movimento mandibular vertical (p<0,001) e uma menor intrusão (0,3mm) da prótese total superior (p=0,002) durante a mastigação após o uso de adesivo. Conclusão: O uso de adesivo para prótese melhorou a satisfação dos usuários de próteses totais e gerou um aumento no movimento mandibular vertical e uma menor intrusão da prótese total maxilar durante a mastigação
Objectives: The objective of this study was to evaluate the effect of a denture adhesive (DA) on patient satisfaction and kinesiographic parameters of complete denture wearers by a cross-over study. Material and Methods: Fifty edentulous patients received one set of new complete dentures. After an adaptation period, the participants were enrolled in the trial and randomized to receive a sequence of treatment: protocol 1- DA use during the first 15 days, followed by the no use of DA over the next 15 days; protocol 2- no use of DA during the first 15 days, followed by use of DA over the next 15 days. Outcomes were assessed after 15 days of each sequence of treatment. A questionnaire was used to evaluate patients´ satisfaction and a kinesiograph instrument was used to record mandible movements and pattern of maxillary complete denture movement during chewing. Wilcoxon test (α=.05) and a paired sample t-test (α=.05) were used to compare satisfaction levels and kinesiographic data, respectively. Results: The use of DA improved the overall patients´ satisfaction (p<.001). Kinesiographic recordings revealed a significant increase (1.7mm) on vertical mandible movements (p<0,001) during chewing and a lower (.3mm) vertical intrusion of the maxillary complete denture (p=0,002) during chewing after use of DA. Conclusion: The use of a DA in complete dentures wearers improved the patients´ satisfaction and change mandible movements, with increases in vertical mandible movements during chewing and lower intrusion of maxillary complete denture
APA, Harvard, Vancouver, ISO, and other styles
47

Pizzol, Karina Eiras Dela Coleta [UNESP]. "Alterações do tecido mole, espaço faríngeo e estabilidade após avanço maxilo-mandibular xom rotação anti-horária e prótese total de ATM." Universidade Estadual Paulista (UNESP), 2008. http://hdl.handle.net/11449/104485.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:33:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-09-23Bitstream added on 2014-06-13T19:23:12Z : No. of bitstreams: 1 pizzol_kec_dr_arafo.pdf: 688008 bytes, checksum: 35e9164526c1e0e9be53fc6134f7ea9a (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Este estudo avaliou a resposta do tecido mole, do espaço faríngeo e a estabilidade após avanço maxilo-mandibular com rotação anti-horária e reconstrução da ATM com próteses totais articulares do tipo TMJ Concepts system®. As mudanças cirúrgicas e pós-cirúrgicas foram analisadas utilizando-se telerradiografias laterais. Com o movimento cirúrgico, houve redução do ângulo do plano oclusal (14,9 ± 8,0°) e aumento do espaço aéreo faríngeo - PASnar (4,9mm). A região anterior da maxila moveu-se para a frente e para cima enquanto a porção posterior, para a frente e para baixo. A mandíbula avançou, e sofreu rotação no sentido anti-horário. No período pós-cirúrgico, a maxila apresentou alterações mínimas no plano horizontal, enquanto todas as medidas mandibulares permaneceram estáveis. A postura da cabeça (OPT/NS) mostrou flexão imediatamente após a cirurgia e extensão em longo prazo, enquanto a curvatura cervical (OPT/CVT) não apresentou mudanças. Os resultados cirúrgicos mostraram ainda aumento das distâncias entre a terceira vértebra cervical (C3) e o mento e desta com o hióide, permanecendo estáveis durante o período de observação. A distância entre o osso hióide e o plano mandibular reduziu durante e após a cirurgia. Já a resposta do tecido mole evidenciou diferentes razões entre tecido duro/mole nos pacientes com e sem genioplastia. As mudanças horizontais na morfologia do lábio superior após avanço, impacção da maxila, sutura em VY e sutura da base alar mostraram maior movimento do que as mudanças observadas em tecido duro. O avanço maxilo-mandibular com rotação anti-horária do plano oclusal associado a próteses totais de ATM (TMJ Concepts system®) mostrou-se estável durante o período de observação. O espaço aéreo faríngeo aumentou...
This study evaluated stability, soft tissue response and oropharyngeal airway space changes after maxillo-mandibular advancement and counter-clockwise rotation with TMJ reconstruction using TMJ Concepts system® total joint prostheses. Lateral cephalograms were analyzed to estimate surgical and post surgical changes. During surgery, the occlusal plane angle decreased 14.9 ± 8.0° and the retroglossal airway space (PASnar) increased 4.9mm. The anterior region of maxilla moved forward and upward while the posterior nasal spine moved downward and forward. The mandible changed forward and rotated in a counter-clockwise direction. At long-term follow-up evaluation the maxilla showed minor horizontal changes, while all mandibular measurements remained stable. Head posture (OPT/NS) showed flexure immediately after surgery and extension long-term post surgery, while cervical curvature (OPT/CVT) had no significant changes. Surgery increased the distances between the third cervical vertebrae (C3) and menton, and C3 and hyoid, remaining stable afterwards. The distance from the hyoid to the mandibular plane decreased during surgery and in the longest follow-up. Soft tissue response indicated different hard/soft tissue ratios between patients with or without genioplasties. Horizontal changes in upper lip morphology after maxillary advancement/impaction, VY closure, and alar base cinch sutures showed greater movement, than observed in hard tissue. TMJ Concepts total joint prostheses associated with maxillo-mandibular advancement and counter-clockwise rotation showed to be stable during the follow-up observation period. Immediate increase in oropharyngeal airway dimension, was influenced by post-surgical changes in head posture but remained stable over the follow-up period. Soft tissue changes showed a known predictable response.
APA, Harvard, Vancouver, ISO, and other styles
48

Medeiros, Flávia Regina Machado de [UNESP]. "Comparação da força de ruptura de alimentos teste entre três diferentes esquemas oclusais para próteses totais." Universidade Estadual Paulista (UNESP), 2013. http://hdl.handle.net/11449/105524.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-26Bitstream added on 2014-06-13T20:25:47Z : No. of bitstreams: 1 000734534.pdf: 2423840 bytes, checksum: 27cd192fc2586553711d9f3f2fdaa7e9 (MD5)
Frente ao reconhecimento de que os movimentos mandibulares são influenciados pela oclusão e, que se pode assumir que o mais efetivo padrão de mastigação para um indivíduo específico irá depender da natureza de sua oclusão, observa-se não existir na literatura correlações concretas entre tipos de oclusões no que diz respeito à função mastigatória. Neste contexto, esse trabalho tem o objetivo de realizar um estudo comparativo laboratorial da força necessária para que ocorra a ruptura de alimentos teste entre os três tipos de esquemas oclusais para próteses totais: Oclusão Convencional, Oclusão Lingualizada e Oclusão Monoplano. Para tanto foi utilizada uma máquina de ensaio universal EMIC a qual se realizou força de compressão sobre um verticulador dotado de dispositivos com os esquemas oclusais em estudo, simulando a força de mordida. A amostra foi formada por três grupos, cada um representando um tipo de oclusão a ser estudada e em cada grupo 5 alimentos teste avaliados, sendo 4 alimentos teste naturais: amêndoa, amendoim, cenoura e café e um alimento teste artificial representado pela silicone (optosil). As oclusões formadas por dentes anatômicos (convencional e lingualizada) tiveram maior desempenho, precisando assim de uma força de mordida menor para realizar a ruptura do alimento teste em relação a oclusão com dentes não anatômicos (monoplano). Houve diferença estatística na maioria das comparações entre os esquemas oclusais estudados em relação à força necessária para causar ruptura dos alimentos-teste, mas nenhum esquema em particular foi melhor do que os outros para todos os tipos de alimento teste.
Three popular occlusal schemes for complete dentures are: conventional balanced occlusion; lingualized balanced occlusion and monoplane occlusion. It was observed that there is few scientific data that allow effective correlation related to the masticatory function between the cited occlusion schemes. In this context, the purpose of this study is to describe a laboratory comparative study of the occlusal force necessary to cause rupture in certain test foods between the conventional, lingualized and monoplane occlusal schemes used to construct complete dentures. The occlusal force was generated by an EMIC universal tests machine compressing the upper side of an articulator where occlusal patterns resembles representing the studied occlusal schemes were fixed. Five different test foods were used in this research, four out five were natural foods (almond, peanut, coffee and carrot) and one was artificial (silicone). It was concluded that: 1. In most comparisons, there were significant statistical differences in the forces applied by the studied occlusal schemes to cause rupture of the test foods, but there was no particular scheme better than the others; 2. In most comparisons the monoplane scheme of occlusion required higher forces to cause the rupture of the test foods.
APA, Harvard, Vancouver, ISO, and other styles
49

Fox, Stephen Richard. "Active hypothermic growth : a novel means for increasing total recombinant protein production by CHO cells." Thesis, Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/32333.

Full text
Abstract:
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 2005.
Includes bibliographical references (p. 225-240).
Recombinant human glycoproteins produced by Chinese Hamster Ovary (CHO) cells are an important class of therapeutic molecules and investigating means of improving the production rate and product quality of these glycoproteins is therefore of great interest. Culturing CHO cells under mild hypothermia (30-33 ⁰C) leads to growth arrest in the G₀/G₁ phase of the cell cycle and, in some cases, causes an increase in specific productivity of recombinant protein, as was shown here for the model CHO cell line producing human interferon-gamma (IFN-[gamma]). Controlled proliferation, achieved by inducing growth arrest in the G₀/G₁ phase by chemical, environmental or genetic means, is commonly used to increase CHO specific productivity and thus there is speculation that enhanced hypothermic productivity is due to growth arrest. However, it was proven here that the positive effect of hypothermia on recombinant protein production is due to elevated IFN-[gamma] mRNA levels instead. At both 32 ⁰C and 37 ⁰C, specific productivity is growth-associated, increasing as the percentage of cells in the S phase increased, demonstrating that a cell line can be both a growth-associated producer and have enhanced productivity under hypothermic conditions. It was hypothesized that the best production platform would be cells actively growing at low temperature and this was proven to be the case using two different methods, namely growth factor supplementation and selection of cells capable of hypothermic growth. Both methods gave multi-fold increases in total IFN-y production compared to the 32 ⁰C and 37 ⁰C controls, thereby validating the novel culture strategy of active hypothermic growth.
(cont.) Cells capable of achieving significant hypothermic growth were also isolated for the non-recombinant CHO-KI cell line and are now available for the future production of any recombinant protein. Glycoprotein quality is partially assessed by the level of glycosylation and IFN-[gamma] contains two potential N-linked glycosylation sites. This thesis gives the first report of a detrimental effect of hypothermic culture on glycosylation, showing a 4-5% decrease in the end-of-batch percentage of 2-sites occupied glycoforms relative to the 37 ⁰C control. However, this negative effect is completely eliminated by culturing under perfusion conditions.
by Stephen Richard Fox.
Ph.D.
APA, Harvard, Vancouver, ISO, and other styles
50

Castro, Eni Vaz Franco Lima de [UNESP]. "Estudo clínico e histopatológico da mucosa palatina em pacientes não usuários de prótese e em usuários de prótese com câmara de sucção." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/102336.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:32:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:21:17Z : No. of bitstreams: 1 castro_evfl_dr_araca.pdf: 208031 bytes, checksum: 9315c888cbc65fc52c5d2cf626bd81c1 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Considerando-se a significativa importância do melhor conhecimento acerca das lesões de maior ocorrência no cotidiano do cirurgião-dentista, justifica-se o estudo das hiperplasias fibrosas inflamatórias em geral, especialmente aquelas de inter-relacionamento com a atuação direta do profissional, como as hiperplasias protéticas. No presente estudo, foram observados os aspectos clínicos e microscópicos da mucosa palatina em pacientes não usuários e usuários de prótese, com a finalidade de se identificar a possibilidade de direta relação entre lesão e suposto agente causal. No sentido de se tentar realizar um estudo mais abrangente e com resultados mais confiáveis, o presente trabalho foi desenvolvido em dois capítulos distintos, analisando-se inicialmente a mucosa palatina clinicamente normal de trinta pacientes usuários e não usuários de prótese total superior, observando-se que a presença de hiperplasia no epitélio de revestimento da mucosa palatina é um achado constante, tanto em usuários como em não usuários de prótese, sendo que a ausência de alterações clínicas nem sempre reflete a mesma normalidade ao exame histopatológico, sem uma relação de dependência entre inflamação e presença de hiperplasia epitelial e vice versa, em ambos os grupos. No segundo capítulo, foram estudados vinte e três pacientes com hiperplasia fibrosa palatina por câmara de sucção, antes e após tratamento compressivo, observando-se que lesões hiperplásicas podem não apresentar um quadro inflamatório crônico, sugerindo que o preenchimento gradativo da área de câmara de sucção é uma opção terapêutica de valor para esses casos.
Being considered the significant importance of the best knowledge concerning the lesions of larger occurrence in the routine of Surgeon Dentist, it is justified the study of the inflammatory fibrous hyperplasias in general, especially those of inter-relationship with the professional's direct performance, as the prosthetic hyperplasias. In the present study, the clinical and microscopic aspects of the palatine mucous membrane were observed in patients wearing or not total prosthesis, with the purpose of identifying the possibility of direct relationship between lesion and supposed causal agent. As an examining to try to accomplish a broader study with more reliable results, the present work was developed in two different chapters, being analyzed the clinically normal palatine mucous membrane of thirty patients initially wearing and not wearing of upper complete denture, being observed that the presence of hyperplasia in the epithelium coating of palatine mucous membrane is a constant discovery, as in wearing as in not prosthesis wearing individuals, and the absence of clinical alterations not always it reflects the same normality to the histopathologic exam, without a dependence relationship between inflammation and presence of epithelial hyperplasia and vice-versa, so much in wearing as in not prosthesis wearing. In the second chapter, twenty-three patients with palatine fibrous hyperplasia for suction chamber were studied, before and after treatment by use of tissue conditioning. It was observed that hyperplasic lesions cannot present a chronic inflammatory picture, suggesting that the gradual completion of the area of suction chamber is an important therapeutic option for those cases.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography