1

Morgan, M. Jane. "Structural analysis of an osseointegrated dental implant system." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1997. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp02/NQ28023.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Habsha, Effrat. "Survival of osseointegrated dental implants in smokers and non-smokers." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 2000. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape4/PQDD_0019/MQ53413.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Barão, Valentim Adelino Ricardo [UNESP]. "Avaliações biomecânicas e biológicas relacionadas às próteses implanto-suportadas e aos implantes osseointegrados." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/105565.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-31Bitstream added on 2014-06-13T20:25:51Z : No. of bitstreams: 1 barao_var_dr_araca.pdf: 1603640 bytes, checksum: 5d48588f784413a0d8cc560b1ff6d9b0 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Objetivos: (1) Investigar o papel de diferentes níveis de pH da saliva artificial (3; 6,5 e 9) no comportamento corrosivo do titânio comercialmente puro (cp-Ti) e da liga Ti-6Al-4V (Capítulo 1); (2) Avaliar a influência do processo de corrosão na afinidade do lipopolissacarídeo (LPS) de Escherichia coli para o cp-Ti e o Ti-6Al-4V (Capítulo 2); (3) Investigar a natureza tribocorrosiva do titânio em saliva artificial em presença de LPS (Capítulo 3); (4) Comparar o efeito de diferentes designs de overdentures implanto-retidas e prótese total fixa implanto-suportada na distribuição de tensões em mandíbula edêntula pelo método de elementos finitos tridimensional (Capítulo 4). Materiais e métodos: Testes eletroquímicos como potencial de circuito aberto, espectroscopia de impedância eletroquímica, e teste potenciodinâmico foram conduzidos. Para o teste de afinidade ao LPS, os espécimes foram tratados com LPS (1,5; 15 e 150 μg/ml) durante 24 horas para avaliar a aderência de LPS. Os discos foram transferidos a cada 24 horas para solução fresca de água livre de LPS até completar 72 horas, para investigar a liberação de LPS. No teste de tribocorrosão, o pH da saliva (6,5), a concentração de LPS (0, 0,15, 15 and 150 μg/ml), a duração do deslizamento (2000 ciclos), freqüência (1,2 Hz) e carga (20 N) foram usados para mimetizar o processo mastigatório. Finalmente, modelos tridimensionais de uma mandíbula edêntula foram construídos. No grupo OR a mandíbula foi restaurada com overdenture retida por implantes não esplitados com sistema de retenção O’ring; nos grupos BC-C e BC as mandíbulas foram restauradas com overdentures retidas por implantes esplintados com sistema de retenção barra-clipe associado ou não a cantilevers distais...
Objectives: (1) To investigate the role of different levels of pH of artificial saliva (pHs 3, 6.5 and 9) under simulated oral environment on the corrosion behavior of commercially-pure titanium (cp-Ti) and Ti-6Al-4V alloy (Chapter 1); (2) To assess the influence of corrosion process on Escherichia coli lipopolysaccharide (LPS) affinity for cp-Ti and Ti-6Al-4V alloy (Chapter 2); (3) To evaluate the tribocorrosive (corrosion/wear) nature of titanium in artificial saliva (pH 6.5) with LPS (Chapter 3); and (4) To compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible by using a three-dimensional finite element analysis. Materials and methods: Standard electrochemical tests, such as open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic tests were conducted in a controlled environment. For LPS affinity test, specimens were treated with LPS (1.5, 15 and 150 μg/ml) for 24 hours to evaluated LPS adherence. Discs were then transferred every 24 hours to fresh LPS-free water, up to 72 hours, to investigate LPS elution. In the tribocorrosion test, the pH of saliva (6.5); LPS concentration (0, 0.15, 15 and 150 μg/ml), sliding duration (2000 cycles), frequency (1.2Hz) and load (20 N) parameters mimicked the mastication process. Finally, tridimensional models of an edentulous mandible were constructed. In the OR group, the mandible was restored with an overdenture retained by unsplinted implants with O’ring attachment; in the BC-C and BC groups, the mandibles were restored with overdentures retained by splinted implants with bar-clip anchor associated or not with distally placed cantilevers, respectively; in the FD group, the mandible was restored with a fixed full-arch implant-supported prosthesis... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
4

Caneva, Marco [UNESP]. "Influência de implantes pós-exodônticos com diferentes configurações sobre os tecidos peri-implantares: estudo experimental em cães." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/103315.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-05Bitstream added on 2014-06-13T21:04:26Z : No. of bitstreams: 1 caneva_m_dr_araca.pdf: 5420643 bytes, checksum: 2a88c9a9a85203bfd0cd8f4fd62affa4 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Objetivo: avaliar a influência da instalação de implantes em alvéolos imediatamente após a extração do elemento dental na regeneração dos tecidos peri-implantares com implantes de diferentes configurações Material e métodos: Nos alvéolos distais dos quartos pré-molares mandibulares de cães, imediatamente após as extrações das raízes dentais, foram instalados implantes cilíndricos com 3,3 mm de diâmetro (grupo controle) e implantes cônicos com 5,0 mm de diâmetro (grupo teste). Foram avaliados histologicamente a regeneração dos tecidos duros e moles peri-implantares após 4 meses do procedimento cirúrgico. Resultados: Todos os implantes apresentaram-se osseointegrados ao tecido ósseo maduro mineralizado. A crista óssea alveolar sofreu reabsorção tanto no grupo teste como controle. A superfície óssea vestibular dos implantes do grupo teste (cônico; 3,6 mm) apresentou maior grau de reabsorção em comparação ao grupo controle (cilíndrico; 1,6 mm). As dimensões dos tecidos moles apresentaram-se semelhantes em ambos os grupos. No entanto, em relação ao ombro do implante, a mucosa peri-implantar localizou-se mais apicalmente no grupo teste em relação ao grupo controle. Conclusão: Este estudo confirmou que a distância entre a superfície do implante e o contorno externo da crista óssea alveolar vestibular influenciou no grau de reabsorção da tábua óssea vestibular. Conseqüentemente, em relação ao ombro do implante, a mucosa peri-implantar será estabelecida em um nível mais apical, se a distância entre a superfície do implante e o contorno externo da crista óssea alveolar for menor
Aim: the aim of the present experiment was to study the influence of implant installation into sockets immediately after tooth extraction on the healing periimplant tissues with implants of various configurations. Material & methods: Transmucosal cylindrical 3.3mm in diameter implants in the control sites, and conical 5.0mm in diameter in the test sites, were installed into the distal socket of the forth mandibular premolars in dogs immediately after tooth extraction. After 4 months, the hard and soft tissue healing was evaluated histologically. Results: All implants were integrated in mineralized mature bone. Both at the test and control sites, the alveolar crest underwent resorption. The buccal bony surface at the implant of the test sites (conical; 3.6mm) was more resorbed compared to the control sites (cylindrical; 1.6mm). The soft tissue dimensions were similar in both groups. However, in relation to the implant shoulder, the periimplant mucosa was located more apically at the test compared to the control sites. Conclusion:The present study confirmed that the distance between the implant surface and the outer contour of the buccal alveolar bony crest influenced the degree of resorption of the buccal bone plate. Consequently, in relation to the implant shoulder, the peri-implant mucosa will be established at a more apical level if the distance between the implant surface and the outer contour of the alveolar crest is small
APA, Harvard, Vancouver, ISO, and other styles
5

Smith, Christopher David. "Prosthodontic maintenance of implant-supported prostheses." Master's thesis, Faculty of Dentistry, 2001. http://hdl.handle.net/2123/4667.

Full text
Abstract:
This work was digitised and made available on open access by the University of Sydney, Faculty of Dentistry and Sydney eScholarship . It may only be used for the purposes of research and study. Where possible, the Faculty will try to notify the author of this work. If you have any inquiries or issues regarding this work being made available please contact the Sydney eScholarship Repository Coordinator - ses@library.usyd.edu.au
APA, Harvard, Vancouver, ISO, and other styles
6

張謙 and Qian Zhang. "Maxillectomy reconstruction by transport distraction osteogenesis." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2002. http://hub.hku.hk/bib/B31243897.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Odo, Caroline Hanada 1987. "Photoelastic analysis of stress distribution around external hexagon and morse taper implants in different immediate loading systems = Análise fotoelástica da distribuição de tensões ao redor de implantes hexágono externo e cone Morse em diferentes sistemas de carga imediata." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288288.

Full text
Abstract:
Orientador: Mauro Antônio de Arruda Nóbilo
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-22T01:43:18Z (GMT). No. of bitstreams: 1 Odo_CarolineHanada_M.pdf: 1232143 bytes, checksum: 6ae3560319ddd48973319b39e8cbe764 (MD5) Previous issue date: 2013
Resumo: Dentre diversos fatores que determinam o sucesso da osseointegração e da reabilitação protética, a biomecânica se destaca como fator fundamental. Utilizando a técnica da fotoelasticidade, o objetivo neste estudo foi avaliar as tensões geradas ao redor de implantes cone morse e hexágono externo osseointegrados após carregamento distal em diferentes técnicas de carga imediata: barra distal, fundição e solda a Laser. Três infraestruturas similares (uma para cada técnica) foram confeccionadas, sobre uma matriz metálica simulando um arco mandibular edêntulo. Cinco implantes foram dispostos de maneira a simular a distribuição clínica para protocolo inferior convencional. Análogos de mini pilares foram fixados na matriz metálica e após procedimento de transferência e obtenção de modelo em gesso especial, foram confeccionadas as infraestruturas protéticas. Estas foram utilizadas em novo procedimento de transferência e posteriormente, instaladas em modelo fotoelástico confeccionado com resina epóxi flexível (GIV, Polipox Indústria e Comércio Ltda - São Paulo - SP - Brasil). Foi realizado um carregamento pontual de 4,9N na região de primeiro molar inferior direito e, posteriormente primeiro molar inferior esquerdo. Foram avaliados cinco pontos pré-determinados ao longo do implante e as imagens foram analisadas no programa Fringes® de maneira qualitativa e quantitativa através da verificação das ordens de franjas ao redor dos implantes osseointegrados. A média dos valores foi submetida à análise de variância para dados com dois fatores de estudo, seguidos pelo teste de Tukey para comparação entre as médias. Os resultados não apresentaram diferença significativa entre as infraestruturas, porém apresentou diferença significativa entre os tipos de conexões. A partir dos resultados obtidos conclui-se que não há diferença na distribuição de tensão entre as técnicas de obtenção de infraestruturas, porém quando observados os tipos de conexão, o implante Cone Morse apresentou melhores resultados em relação à distribuição de tensão
Abstract: The objective of this study was to evaluate the stresses generated around morse taper and external hexagon osseointegrated implants after distal loading in different immediate loading techniques: distal bar, casting and laser welding. Three similar infrastructures (one for each technique) were fabricated on a metal matrix simulating an edentulous mandible arch. Five implants were arranged to simulate the clinical distribution of conventional lower protocol. Analogs of the implants were fixed in a metal matrix and a transfer procedure was made. After obtaining a special plaster model, the prosthetic infrastructures were fabricated. These were used on a new transfer procedure and subsequently installed in a photoelastic model made with flexible epoxy resin (GIV Polipox Industry and Commerce Ltd - São Paulo - SP - Brazil). A load application of 4.9N was performed at the region of lower right first molar and subsequently lower left first molar. Five predetermined points along the implant were evaluated and the images were analyzed in Fringes ® program in qualitative and quantitative way by checking the orders of the fringes around the dental implants. The mean values were statistically analyzed using a 2-Way analysis of variance and Tukey test. The results showed no significant difference between the infrastructure obtaining techniques, but significant difference was seen between the types of connection. From the results obtained it is concluded that the Morse taper implant showed better results in terms of stress distribution
Mestrado
Protese Dental
Mestra em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
8

Fitzgibbon, Daniel Nathan, and n/a. "Assessment and comparison of osseointegration in conventionally and immediately restored titanium implants in a sheep model." University of Otago. School of Dentistry, 2008. http://adt.otago.ac.nz./public/adt-NZDU20081201.161832.

Full text
Abstract:
Objectives: The present work was under taken to compare osseointegration of immediately and delayed restored implants in a sheep model, and to compare methods of assessing osseointegration. Methods: Twenty wide-platform implants were placed in the posterior mandibles of 10 sheep, 3 months after premolar extractions. Ten were control implants placed and restored after 3 months of submerged healing. Ten were test implants placed contralaterally and immediately restored. Animals were sacrificed after a further 3 months of healing. At each experimental stage implant stability was measured with resonance frequency analysis (RFA) and standardized radiographs were taken. Tissue blocks with the implants were embedded in acrylic resin. The specimens were analysed by three-dimensional micro tomogram (micro-CT) images. Ground sections of the tissue blocks were then prepared for light microscopy and quantitative morphometry. Morphometric parameters computed by both methods were mean percent bone-to-implant contact (BIC) and mean percent bone density (BD). Radiographic, stability and morphometric measurements were compared statistically. Results: The survival rate was 60% (controls) versus 40% (test) (p=0.28). Mean crestal bone levels after three months restoration did not differ significantly between control (5.54 � 0.92) and test groups (4.35 � 1.61) (p=0.56). All surviving implants were stable at stage three and RFA values in implant stability quotient (ISQ) did not differ significantly between the two groups (test 82.3 � 3.9 versus control 78.8 � 4.3, p=0.36). No correlation was found between crestal bone loss and RFA (Spearman�s rho =-0.27, p=0.46). Histomorphometric analysis found no statistical difference (%BIC test 65.65 � 12.7%, control 53.36 � 6.41%, p=0.18; and %BD test 54.84 � 8.45%, control 64.69 � 13.57%, p=0.11). A similar trend was observed for mean micro-CT (%BIC test 65.72 � 72, control 50.84 � 4.19, p=0.11). Histology revealed high density inflammatory infiltrates beneath the sulcular and pocket epithelium. No significant difference was found between histomorphometric (HMA) and microCT analysis (%BIC p=0.08, %BD p=0.08). A statistically significant correlation was observed between HMA and microCT for %BIC (Spearman�s rho = 0.89, p=0.02) but not %BD (Spearman�s rho = 0.51, p=0.30). Conclusions: The results suggest that the sheep mandibular model has limited potential for evaluation of implants designed for poor quality bone and for the assessment of implant loading protocols. This thesis does highlight the potential for the use of this model in peri-implantitis studies. The results suggest that morphometric variables determined by HMA and microCT analysis are comparable, however further studies are required to standardize the microCT protocol to reduce metal artifacts and enhance bone-implant contrast.
APA, Harvard, Vancouver, ISO, and other styles
9

Moraes, Paulo Hemerson de 1982. "Rehabilitation of fully edentulous maxilla = retrospective survival analysis of dental implants in native x autogenous bone and proposed technique for bone reconstruction with rhBMP-2 = Reabilitações de maxilas totalmente edêntulas: análise retrospectiva de sobrevida de implantes dentários em osso nativo x enxerto autógeno e proposta de técnica para reconstrução óssea com rhBMP-2." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289417.

Full text
Abstract:
Orientador: José Ricardo de Albergaria Barbosa
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-24T03:15:23Z (GMT). No. of bitstreams: 1 Moraes_PauloHemersonde_D.pdf: 8285563 bytes, checksum: e294a6dc0647058066633e61386f29b1 (MD5) Previous issue date: 2013
Resumo: Em maxilas severamente absorvidas, como tratamento de reabilitação, podem ser utilizados os implantes dentais osseointegráveis convencionais. Todavia, nestas situações, estão presentes obstáculos para a instalação dos implantes como: quantidade insuficiente e qualidade inadequada do osso encontrado na maxila. Nestas situações, são necessárias cirurgias reconstrutivas para restabelecer as dimensões do rebordo avelolar em espessura e altura possibilitando assim a instalação adequada destes implantes. Geralmente, essas reconstruções utilizam osso autógeno retirado de algum sitio doador do paciente, como a calota craniana, costela e crista do ilíaco. Alternativamente, com os avanços da engenharia tecidual, a rhBMP-2 (recombinant human bone morphogenethic protein-2) surgiu eliminando a necessidade de qualquer remoção de sítio doador como também qualquer outro biomaterial nas reconstruções ósseas dos maxilares deixando o procedimento com menor morbidade e maior aceitabilidade dos pacientes. Desta forma, a presente pesquisa apresenta 2 estudos descritos nos capítulos a seguir. CAPÍTULO 1: O objetivo deste estudo foi avaliar a sobrevida de implantes instalados em osso nativo de maxilas como também nas reconstruídas com osso autógeno. Foi obtido um acompanhamento de 8-10 anos com pacientes de ambos os grupos reabilitados com próteses fixas sobre implantes dentais. O sucesso dos implantes em maxilas reconstruídas com ósso autogeno não apresentaram diferenças estatísticas à implantes inseridos em maxilas com osso nativo. CAPÍTULO 2: O objetivo deste estudo foi apresentar uma nova técnica de reconstrução óssea de maxila utilizando rhBMP-2 objetivando previsibilidade e melhores resultados no aumento do volume ósseo necessário. A técnica sugerida ofereceu bons resultados no volume ósseo a ser obtido nas reconstruções ósseas de maxila com rhBMP-2.
Abstract: In maxillary severely absorbed as rehabilitation treatment, can be used conventional dental implants. However, these situations are present obstacles to the installation of the implants as insufficient and inadequate quality of bone found in the jaw , as well as the expansion of the maxillary sinus pneumatization . In these situations, it is necessary reconstructive surgery to restore the dimensions of thickness and height on rim thus allowing proper installation of these implants. Generally, these reconstructions using autogenous bone taken from a donor site from the patient , such as calota craneal , rib and the iliac crest . Alternatively, with advances in tissue engineering, rhBMP-2 (recombinant human bone morphogenethic protein-2) appeared eliminating the need to remove any donor site as well as any other biomaterial in the maxila bone reconstruction procedure with leaving the lower morbidity and higher patient acceptability. Given the above, this research presents two studies described in the following chapters. CHAPTER 1: The objective of this study was to evaluate the survival of implants placed in native bone in the maxilla as well as in maxilla reconstructed with autogenous bone. We obtained a follow-up of 8-10 years with both groups of patients rehabilitated with fixed prostheses on dental implants. The survival of implants in maxilla was reconstructed with autogenous bone implants inserted into the lower maxilla with native bone. CHAPTER II: The objective of this study was to present a new technique for reconstruction of maxilla bone using rhBMP-2 seeking precision in increased bone volume needed. The suggested technique offered precision in bone volume to be obtained in the maxilla bone reconstruction with rhBMP-2.
Doutorado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
10

Guben, Tamara Heidi. "Bone quality in osseointegration : a biomechanical study, using the rat tibia, and clinical evaluation." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1998. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape11/PQDD_0004/MQ44175.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Kim, James H., and n/a. "A comparison of osseointegration in conventionally versus immediately restored implants in a sheep model." University of Otago. School of Dentistry, 2007. http://adt.otago.ac.nz./public/adt-NZDU20071206.162016.

Full text
Abstract:
Objectives: To compare the osseointegration of conventionally and immediately restored tapered implants in a split-mouth animal model, and to compare different methods of analysis for measuring osseointegration. Materials & Methods: Twenty tapered implants were placed in the posterior mandibles of ten sheep, three months after premolar extractions. Ten control implants were placed and were restored after three months submerged healing. Ten test implants were placed on the contralateral side at this time and immediately restored. Animals were sacrificed after a further three months healing. Resonance frequency analysis (Implant Stability Quotient, ISQ), and standardized radiographs were taken at all stages. Alveolar bone height relative to the implant shoulder was measured on digitized radiographs. Histomorphometric and micro-Computed Tomograph ([mu]CT) morphometric analysis for Bone-to-Implant Contact (BIC) and Bone Density (BD) were performed. Radiographic, stability and morphometric measurements were compared statistically. Results: Only three (30%) of conventionally restored and two (20%) immediately restored implants survived (p = 0.74). Mean crestal bone level after three months loading differed significantly (control 5.3 � 0.9 mm versus test 0.9 � 1.3 mm; p = 0.02). Control implants lost more crestal bone over three months than test implants but this was not statistically significant (3.5 � 1.0 mm versus 0.7 � 1.0 mm; p = 0.06). The test group showed a higher mean ISQ value (85.4 � 6.9) compared to the control group (72 � 14.4; p = 0.349). Both groups showed a slightly reduced stability during the loaded period. This was more marked for the test group but not statistically significant (-0.5 � 3.8 ISQ versus -4.35 � 6.6 ISQ; p = 0.8). A statistically significant negative correlation was found between the loss of crestal bone and ISQ with loading (Pearson�s coefficient of correlation r = -0.473 p = 0.026). Both groups showed a statistically significant difference in BIC for both histomorphometric analaysis (HMA); p = 0.039 and [mu]CT morphometric analysis; p = 0.013. When the two forms of morphometric analysis were compared, HMA and [mu]CT morphometric analysis differed significantly for both BIC (p = 0.05) and BD (p = 0.048). However, a statistically significant correlation was found between the two measuring techniques, for both BIC (r = 0.335 p = 0.013) and BD (r = 0.439 p = 0.01). Conclusions: The placement of wide-bodied 3i Osseotite NT[TM] tapered implants into sheep mandible resulted in high failure rate regardless of the loading protocol. The sheep mandibular model may be inappropriate as a model for evaluation of immediate loading, and to test implants which are designed for soft bone. Further investigations are needed to look into the variations in bone microstructure along with their impact on the mechanics of implant-bone union. Although a statistically significant difference was found between the two measurement techniques, a positive correlation was found between HMA and [mu]CT morphometric analysis suggesting non-invasive methods may have a potential in assessing osseointegration. Further research is required to optimize the variables in [mu]CT analysis, such as, voltage, filters, and thresholding to minimize artifacts and to maximize bone contrast when titanium implants are present.
APA, Harvard, Vancouver, ISO, and other styles
12

Salles, Angelo Emilio Barroso de. "Analise fotoelastica da distribuição de tensões em dois sistemas de proteses mandibulares sobre implantes : barra distal e solda a laser." [s.n.], 2008. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288262.

Full text
Abstract:
Orientador: Mauro Antonio de Arruda Nobilo
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-12T16:14:35Z (GMT). No. of bitstreams: 1 Salles_AngeloEmilioBarrosode_M.pdf: 10746117 bytes, checksum: 7a6d08147fb33c8d235cc7df5f8be032 (MD5) Previous issue date: 2008
Resumo: Este estudo avaliou por meio de análise fotoelástica, a distribuição in vitro das tensões geradas na interface "osso/implante" em próteses mandibulares, tipo protocolo, comparando duas técnicas de confecção: Solda a laser e Barra Distal (Neodent, Curitiba - PR) onde não se utiliza infra-estrutura metálica. Foram confeccionadas duas próteses com design similares (uma para cada técnica), sobre uma matriz metálica simulando um arco mandibular edêntulo, onde foram instaladas cinco réplicas de implantes de corpo único (GT- Neodent, Curitiba - PR). A partir de um molde de silicone de duplicação (Silibor - Clássico Artigos Odontológicos Ltda.) foi confeccionado um modelo em resina fotoelástica (Araldite GY279BR - Araltec Produtos Químicos Ltda. Guarulhos - SP) com cinco implantes GT (Neodent, Curitiba - PR) incorporados. Após a instalação de cada prótese sobre o modelo fotoelástico, utilizando 10 N/cm para aperto dos parafusos, foi realizada análise fotoelástica. Em seguida, foi aplicada carga oclusal de 100 N em toda extensão de cada prótese, com auxílio de uma placa metálica posicionada sobre a face oclusal dos dentes, e então realizada nova análise das tensões. Estas análises foram executadas com o auxílio de um polariscópio circular acoplado a uma máquina fotográfica digital (H1 - Sony, Japão), que permitiu a visualização das franjas e registrou através de fotografias digitais o comportamento das mesmas ao redor dos implantes no modelo fotoelástico. De acordo com os resultados, concluiu-se que a técnica utilizando Barra Distal distribuiu melhor, e transmitiu com menos intensidade, após o aperto dos parafusos, as tensões geradas na interface "osso/implantes" do que a técnica utilizando solda a laser. No entanto, ocorreu o inverso após o carregamento oclusal.
Abstract: The aim of this study was to evaluate through photoelastic analysis, the in vitro distribution of the generated tensions in the "bone/ implant" interface in mandibular prostheses, protocol type, comparing two different working techniques: the idealized by Branemark and Distal Bar (Neodent, Curitiba - PR) where framework is not used. Two similar prostheses were made (one for each technique), on a metal matrix simulating an edentulous mandible, where five replications of single body implant were installed (GT-Neodent, Curitiba - PR). From a silicone mold for duplication (Silibor - Classico Artigos Odontológicos Ltda.), a model in photoelastic resin was created (Araldite GY279BR - Araltec Produtos Quimicos Ltda., Guarulhos - SP) with five GT implants (Neodent, Curitiba - PR) embedded. After the installation of each prosthesis on the photoelastic model, using 10 N/cm for tightening the screws, a photoelastic analysis was performed. Then a 100 N occlusion load was applied throughout each prosthesis extension with the help of a metal plate positioned on the occlusal face of the teeth, and then a new analysis of the tensions was conducted. These analyses were performed with the help of a circular polariscope attached to a digital camera (H1 - Sony, Japan), which allowed the visualization of the fringes and recorded by digital photos the behaviour of the implants. According to the results, it was concluded that the Distal Bar technique distributed better, and transmitted with less intensity, after the tightening of the screws, the generated tensions to the system "bone/implants" than the laser welding. However, it happened the opposite after the occlusal load.
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
13

Lima, Vicente José Muratore de. "\"Estudo prospectivo dos parâmetros periodontais e peri-implantares dos pilares que recebem prótese dento-implanto-suportada\"." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/23/23137/tde-30102006-153856/.

Full text
Abstract:
Desde a introdução dos implantes na Odontologia, controvérsias tem havido acerca da propriedade de conectar os implantes a dentes em próteses fixas. Os implantes osseointegrados não apresentam nenhum ligamento periodontal e são mais firmemente ancorados ao osso. A diferença apresentada nesta ancoragem tem levantado preocupações acerca de o implante osseointegrado, por sua firme fixação ao osso, apresentar pouca flexibilidade para dividir as cargas funcionais com os dentes conectados. O presente estudo teve como propósito acompanhar prospectivamente os parâmetros periodontais ? índice gengival, índice de sangramento, profundidade de sondagem e perda de inserção entre o dente pilar de uma prótese dento-implanto-suportada com o dente colateral do mesmo paciente, e também os parâmetros peri-implantares dos implantes que suportam estas próteses - índice gengival; índice de sangramento; profundidade de sondagem e perda de inserção. Para verificar a perda de inserção foi utilizado o recurso da subtração radiográfica da região em que a prótese foi instalada, com tomadas radiográficas efetuadas no momento da instalação da prótese, decorridos seis meses e após 12 meses de uso, com o objetivo de verificar a ocorrência, ou não, de alteração do suporte ósseo peri-implantar. Foram selecionados 12 pacientes com estado de saúde normal, apresentando área posterior de mandíbula edêntula onde estava indicada a reabilitação protética por meio de prótese fixa unindo dente a implante. Estes foram tratados com implante de um estágio de 10 mm padrão da Straumann (ITI), que apresenta um pescoço polido de 2.8mm, onde a porção do implante que permanece intra-óssea apresenta uma superfície tratada, com diâmetro de 4.1mm. O implante foi instalado no espaço onde se localizaria o retentor mais distal da futura prótese parcial fixa, seguindo o protocolo. As radiografias digitais obtidas foram avaliadas num software de subtração radiográfica, Matrox Inspector versão oito, para verificar a alteração da variação de densidade óptica e contraste das radiografias quando superpostas, sendo os valores observados no implante comparados com os critérios de sucessos , amplamente abordados nos estudos verificados. Todos os implantes instalados nos pacientes osseointegraram, não houve registro de alteração óssea ao redor dos mesmos e nos dentes pilares das próteses em avaliações feitas após seis meses e 12 meses. As próteses continuaram clinicamente em excelente estado após 12 meses de avaliação nas análises clínicas e radiográficas. Ainda, de acordo com o teste de Sinais de Postos de ilcoxon, concluiu-se estatisticamente que não houve diferença nos parâmetros peri-implantares de cada paciente durante os períodos analisados (zero, seis meses e 12 meses), bem como quando comparados com os respectivos dentes colaterais.
Since the introduction of implants in Dentistry, controversies have arisen about the possibility of connecting implants to teeth in fixed prostheses. Osseointegrated implants do no present any periodontal ligature and are more firmly anchored to the bone. The difference presented by this type of anchorage has led to some concern about the limited flexibility of the osseointegrated implant to share the functional loads with the connected teeth. This study intended to follow-up prospectively the periodontal parameters bleeding index, probing depth between the pillar tooth of an implant supported prosthesis with one control tooth of the same patient and also the implants that support theses prostheses. That is why subtraction radiography of the region in which the prosthesis was placed was used, with radiographs taken at prosthesis placement, after six months and one year of use to verify if the periimplant osseous support had or had not undergone changes. Twelve patients with normal health conditions were selected who presented a posterior area edentulous jaw where a prosthetic rehabilitation by a fixed prosthesis joining tooth to implant was indicated. Patients were treated with an implant of one stage of 10mm standard Straumann (ITI) with a 2.8 mm polished neck, in which the remaining intraosseous portion of the implant has a treated surface of 4.1 mm diameter. The implant was placed in the space where according to the protocol, the more distal retainer of the future fixed partial prosthesis would be located. Digital radiographs were assessed with a subtraction radiography software Matrox Inspector version eight, to corroborate the change of contrast in the radiographs when superimposed, with values observed in the implant compared with the success criteria , widely mentioned in surveyed studies. All implants placed in patients became osseointegrated. There was no record of bone change around them and in the dental pillars of the prostheses at the one year follow-up. Prostheses continue to be in excellent conditions after the one year follow-up based upon clinical and radiographic analyses. Furthermore, in accordance with the Wilcoxon test of matched pairs and signed rank, it was concluded that there was no statistical difference between each group of each patient during the time period analyzed (baseline and one year) as well as when the pillars were compared to their respective controls.
APA, Harvard, Vancouver, ISO, and other styles
14

Raines, Andrew Lawrence. "The role of biomaterial properties in peri-implant neovascularization." Diss., Georgia Institute of Technology, 2011. http://hdl.handle.net/1853/41178.

Full text
Abstract:
An understanding of the interactions between orthopaedic and dental implant surfaces with the surrounding host tissue is critical in the design of next generation implants to improve osseointegration and clinical success rates. Critical to the process of osseointegration is the rapid establishment of a patent neovasculature in the peri-implant space to allow for the delivery of oxygen, nutrients, and progenitor cells. The central aim of this thesis is to understand how biomaterials regulate cellular and host tissue response to elicit a pro-angiogenic microenvironment at the implant/tissue interface. To address this question, the studies performed in this thesis aim to 1) determine whether biomaterial surface properties can modulate the production and secretion of pro-angiogenic growth factors by cells, 2) determine the role of integrin and VEGF-A signaling in the angiogenic response of cells to implant surface features, and 3) to determine whether neovascularization in response to an implanted biomaterial can be modulated in vivo. The results demonstrate that biomaterial surface microtopography and surface energy can increase the production of pro-angiogenic growth factors by osteoblasts and that these growth factors stimulate the differentiation of endothelial cells in a paracrine manner and the results suggest that signaling through specific integrin receptors affects the production of angiogenic growth factors by osteoblast-like cells. Further, using a novel in vivo model, the results demonstrate that a combination of a rough surface microtopography and high surface energy can improve bone-to-implant contact and neovascularization. The results of these studies also suggest that VEGF-A produced by osteoblast-like cells has both an autocrine and paracrine effect. VEGF-A silenced cells exhibited reduced production of both pro-angiogenic and osteogenic growth factors in response to surface microtopgraphy and surface energy, and conditioned media from VEGF-A silenced osteoblast-like cell cultures failed to stimulate endothelial cell differentiation in an in vitro model. Finally, the results show that by combining angiogenic and osteogenic biomaterials, new bone formation and neovascularization can be enhanced. Taken together, this research helps to provide a better understanding of the role of material properties in cell and host tissue response and will aid in the improvement of the design of new implants.
APA, Harvard, Vancouver, ISO, and other styles
15

Abla, Marcelo Sabbag [UNESP]. "Avaliação da incorporação de enxertos ósseos homógenos em humanos: análises histológica e imunoistoquímica." Universidade Estadual Paulista (UNESP), 2012. http://hdl.handle.net/11449/103325.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-27Bitstream added on 2014-06-13T19:22:10Z : No. of bitstreams: 1 abla_ms_dr_araca.pdf: 493211 bytes, checksum: 7b996be2b8e49d11e130d4903e67a50b (MD5)
O osso homógeno fresco congelado tem sido utilizado no intuito de substituir o osso autógeno. No entanto as suas propriedades de osteoindução e até mesmo osteocondução não estão bem conceituadas na literatura científica. Esse trabalho teve por objetivo avaliar amostras de tecido ósseo homógeno enxertados em humanos através das análises qualitativas histológica e imunoistoquímica. Para tal, dez pacientes previamente selecionados foram submetidos à cirurgia de reconstrução de defeitos ósseos em espessura, usando enxerto ósseo homógeno em bloco fresco congelado estabilizado e fixado por meio de parafusos bicorticais. Após período de integração de seia meses foi realizado procedimento de reabertura para instalação dos implantes osseointegráveis. Neste momento cirúrgico, amostras do enxerto ósseo foram removidas por meio de broca trefina. As amostras foram fixadas em formol 10%, levadas ao processamento para corte descalcificado em parafina e coradas por hematoxilina e eosina. Realizou-se processamento imunoistoquímico para a expressão da enzima Caspase 3. As lâminas foram levadas à microscopia óptica para realização das análises histológica e imunoistoquímica qualitativas. Os resultados mostraram tecido ósseo não vital, com poucas áreas de deposição de osso neoformado sobre a matriz amorfa, presença de infiltrado inflamatório com áreas de osteomielite e imunomarcação expressiva da enzima Caspase 3. Diante da metodologia empregada e dos resultados obtidos concluiu-se que o enxerto homógeno apresentou somente a propriedade biológica de osteocondução durante a fase de incorporação de seis meses
Allogeneic bone has been used fresh frozen in order to replace bone autograft. However, the properties of osteoinduction and osteoconduction are not even well-regarded in the scientific literature. This work aimed to evaluate samples of homogenous bone grafts in humans by qualitative histological analysis and immunohistochemistry. For this ten pre-selected patients underwent surgical reconstruction of bone defects in thick, homogenous bone graft using fresh frozen block stabilized and fixed by bicortical screws. After integration period of six months reopening procedure was performed for installation of osseointegrated implants. At this surgical time bone graft samples were removed by means of drill trephine. The samples were fixed in formalin 10%, taken to court for processing decalcified paraffin, and stained with hematoxylin and eosin. Immunohistochemistry was performed processing for the expression of the enzyme Caspase 3. The slides were brought to light microscopy to carry out the qualitative histology and immunohistochemistry. The results showed non-vital bone tissue, with few areas of deposition of new bone formation on the amorphous matrix, presence of chronic inflammatory infiltrate with areas of osteomyelitis, and immunostaining expressive of the enzyme Caspase 3. Given the methods employed and the results obtained it was concluded that the graft showed only a homogenous biological property of osteoconduction, during the incorporation of six months
APA, Harvard, Vancouver, ISO, and other styles
16

Daroz, Luiz Gustavo Dias. "Fresamento corretivo de estruturas implanto-retidas : influencia na adaptação marginal e na confiabilidade do teste do parafuso unico." [s.n.], 2006. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289193.

Full text
Abstract:
Orientador: Guilherme Elias Pessanha Henriques
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-06T09:25:51Z (GMT). No. of bitstreams: 1 Daroz_LuizGustavoDias_M.pdf: 1050394 bytes, checksum: 25c85e7dd89cc812e9e871cdc982a3a1 (MD5) Previous issue date: 2006
Resumo: A obtenção de uma peça perfeitamente adaptada aos componentes de retenção, mantendo a resistência estrutural a custo acessível é o principal objetivo durante a construção de uma prótese implanto-retida de múltiplos elementos. Além disto, julgar a qualidade da adaptação das peças depende da confiabilidade dos métodos existentes para determinação da passividade. O objetivo deste estudo foi determinar o desajuste marginal de infra-estruturas metálicas implanto-retidas tipo monobloco antes e após o fresamento corretivo destas peças empregando retificador manual. Avaliou-se ainda a hipótese de que os procedimentos de fresamento corretivo podem ter influência sobre a confiabilidade do teste do parafuso único utilizado para averiguação de adaptação marginal de peças múltiplas sobre implantes. Foram confeccionadas 40 infra-estruturas metálicas pela técnica do monobloco, sendo 20 fundidas em titânio comercialmente puro (Ti c.p.) e outras 20 fundidas em liga de cobalto-cromo (Cr-Cr). Para tal, utilizou-se matriz metálica simulando a disposição clínica de implantes osseointegrados na região interforames mentonianos contendo 5 análogos de pilares cônicos para peças múltiplas padrão Branemark (Micro-Unit - Conexão) e cilindros protéticos calcináveis compatíveis. As peças confeccionadas em Ti c.p. e em Co-Cr, foram subdivididas em 2 subgrupos (n=10) de acordo com a seqüência de retificação a que foram impostas: Seqüência A ¿ fresamento corretivo das bordas de adaptação dos cilindros protéticos seguido do fresamento corretivo da base de assentamento da cabeça do parafuso protético ao pilar; e, Seqüência B ¿ fresamento corretivo da base de assentamento da cabeça do parafuso protético ao pilar seguido do fresamento corretivo das bordas de adaptação dos cilindros protéticos. A conduta forneceu um total de 4 grupos experimentais (Titânio A e B; Co-Cr A e B). As leituras de desajuste marginal, realizadas sobre a matriz metálica e com auxílio de um microscópio mensurador, foram baseadas na técnica do parafuso único e realizadas em cada estrutura antes e após cada etapa de retificação corretiva. As médias de desajuste marginal de cada estrutura foram calculadas e consideradas como uma unidade para a análise estatística. O teste de Friedman foi aplicado com nível de significância de 5% para avaliar o efeito dos diferentes passos de retificação sobre o desajuste marginal. Nos Grupos Ti A e B, assim como no Grupo Co-Cr A, não foi observada diferença significativa entre as condições experimentais (Grupo Ti A, p=0,9048; Grupo Ti B, p=0,273 e Grupo Co-Cr A, p=0,4966). Porém, diferenças estatisticamente significativas foram observadas no Grupo Co-Cr B, após a retificação corretiva das bordas dos cilindros fundidos (p=0,0017). Foi concluído que os procedimentos de fresamento corretivo não mostraram efeito significativo sobre a adaptação marginal das pecas de titânio. Contudo, em um grupo de peças fundidas em Co-Cr, a retificação das bordas dos cilindros mostrou efeito adverso sobre a passividade. Os procedimentos de fresamento corretivo parecem não apresentar influência significativa sobre a confiabilidade do teste do parafuso único, porém, devem ser realizados cuidadosamente, necessitando de aperfeiçoamentos para uma utilização segura
Abstract: The fabrication of a passively fitting framework over abutments and fixtures, maintaining its structural integrity and with a low costs, is the ultimate goal of the construction process of a multi-unit implant-support prosthesis. Furthermore, the accuracy and reliability of the passive fit determination methods have a crucial hole on framework misfit analysis. The objective was to evaluate the passive fit by the single-screw test method of cast commercially pure titanium (CP Ti) implantsupported frameworks after the corrective finishing of cast cylinders fitting borders and screw seats. The hypothesis tested was that finishing procedures could affect the single screw test measurements reliability. Were fabricated 40 frameworks by onepiece casting method, being 20 CP Ti frameworks and others 20 Co-Cr frameworks. A metallic index containing 05 Branemark-type multi-unit abutment analogs and respective calcinable cylinders were used to frameworks fabrication. The CP Ti and Co-Cr frames were assembled in 2 sub-groups (n=10) accordingly with the finishing sequence proposed: Group A - corrective finishing of cast cylinder borders followed by corrective finishing of cast cylinder screw seats - and Group B - corrective finishing of cast cylinder screw seats followed by corrective finishing of cast cylinder borders-. This conduct produce 4 experimental groups (CPTi A and B; Co-Cr A and B). The marginal gaps, assessed over the metallic matrix using a traveling microscope, were carried out before and after each corrective finishing step accordingly with one screw test protocol. The marginal misfit means of each framework was considered as a unit to statistical analyses. The Friedman¿s test was used with significance level set as 5% to analyze the effect of the different corrective finishing steps over frameworks passive fit. In the CPTi A and B Groups, and in the Co-Cr A Group, there was no significant differences between experimental conditions (Group CPTi A, p=0.9048; Group CPTi B, p=0.273 and Grupo Co-Cr A, p=0.4966). However, in the CPTi B Group, a significant difference was found after cast cylinder fitting borders corrective finishing (p=0.0015). It was concluded that the finishing process does not show any effect over Ti framewoks misfit values. However, to a group of Co-Cr frames, the fitting borders corrective finishing has a deleterious effect over passivity. The corrective finishing procedures seamed do not influence the single-screw test reliability, nevertheless, it should be used carefully and requires further improvements to guarantee a sever usage
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
17

Barbosa, Bruno Aiello. "Análise microscópica da necrose óssea provocada pelo aquecimento friccional durante a confecção de alvéolos cirúrgicos para implantes osseointegráveis." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/25/25136/tde-02072009-153420/.

Full text
Abstract:
A utilização de implantes osseointegráveis como substituto dentário tornou-se amplamente adotada desde a instalação e relato de sucesso dos primeiros implantes em seres humanos. A cirurgia para instalação de implantes osseointegráveis pode ser realizada em dois estágios, aguardando-se o período de osseointegração para confecção da prótese de transição ou definitiva; ou por estágio único, conhecida como carga imediata ou função imediata. Ambas as técnicas necessitam da confecção de um alvéolo cirúrgico, para isto utiliza-se de brocas em aço inoxidável. Durante a perfuração do alvéolo promove-se o aumento da temperatura da broca devido à fricção, aquecendo o tecido ósseo adjacente e podendo provocar a Necrose Óssea Térmica. A queima pode acometer uma pequena parte cortical ou comprometer todo alvéolo cirúrgico. A proposição deste trabalho foi analisar microscopicamente a existência ou não da necrose óssea térmica provocada por brocas durante a confecção de alvéolos cirúrgicos para implantes osseointegráveis quanto: à comparação entre broca nova e broca com desgaste; a interferência da irrigação externa. Além disso, propõe-se demonstrar por achados microscópicos o comportamento tecidual e celular frente a essas variantes. Para o estudo foram utilizados cinco pedaços de costela bovina removidas um dia após a morte do animal. Para o estudo as variantes foram: brocas novas, brocas velhas, presença ou não de irrigação externa. Os corpos de prova foram divididos em 4 grupos (N=5), combinando-se todas as possibilidades de variância. Após as perfurações, seguindo-se o protocolo de dilatação progressiva (BRÅNEMARK, 1980), confeccionaram-se lâminas histológicas para análise em microscopia óptica de luz. Com a contagem das células (osteócitos normais e osteócitos com núcleo picnótico) e das lacunas (osteoplastos), quantificou-se a viabilidade óssea de acordo com a necrose óssea térmica provocada durante o aquecimento friccional. Após análise estatística (p≤0,05), verificou-se que as perfurações realizadas utilizando-se de irrigação externa 58,46% dos osteócitos apresentavam-se normais (viáveis), 30,15%, com lacunas vazias e 11,38% com os núcleos picnóticos. Já as perfurações confeccionadas por brocas desgastadas resultaram em 35,93% dos osteócitos normais, 16,18% com núcleos picnóticos e 47,89% de lacunas vazias. Correlacionando as variantes broca e irrigação, verifica-se a predominância de osteócitos normais como sinal de viabilidade óssea nos grupos: com irrigação e broca nova (66,10%) e com irrigação e brocas desgastadas (50,82%). Nos grupos onde os alvéolos foram realizados com brocas novas sem irrigação e de brocas desgastadas sem irrigação, observa-se a inviabilidade óssea pela predominância de osteócitos com núcleo picnótico e lacunas vazias, demonstrando a degeneração celular provocada pelo calor. Após o estudo, concluímos que a irrigação externa e a qualidade do corte das brocas são fundamentais e influenciam na manutenção da viabilidade óssea. Além disso, microscopicamente as células ósseas demonstram alterações morfológicas após o aquecimento friccional.
The use of osseointegrated implants as dental substitute became widely adopted since the installation of the first implant in human beings. The surgery for installation of osseointegrated implants can be carried through in two stages, waiting the period for osseointegration to do the definitive prosthesis or; in one stage, known as immediate loading or immediate function. Both the techniques need the confection of a surgical alveolus, for this are used stainless steel drills. During the alveolus perforation the friction increases the drill temperature which promotes the heating on adjacent bone tissue favoring the thermal osteonecrosis. The heating can commit a small cortical part or compromise all surgical alveolus. The aim of this study was to evaluate by microscopic analysis the existence of the thermal osteonecrosis or not, comparing new and old drills and, the interference of the external irrigation. For the present investigation five pieces (N=5) of bovine ribs had been removed one day after the death of the animal. The ribs were divided in 4 groups agreeing all the variance possibilities. After the perforations, following the protocol of gradual dilatation, we confectioned histological blades for analysis by light microscopy. We quantified the osseous viability by counting of the normal osteocytes, osteocytes with pyknotic nuclei and the empty lacunae. After statistical analysis (p≤0.05), we verified that the perforations done using external irrigation 58.46% of the osteocytes were presented normal (viable), 30.15% with empty lacunae and 11.38% with pyknotic nuclei. Moreover, the perforations confectioned with old drills had resulted in 35.93% of normal osteocytes, 16.18% of pyknotic nuclei and 47.89% of empty lacunae. Correlating the variants, drill and irrigation, we verified the predominance of normal osteocytes, as a signal of osseous viability, in the groups with irrigation/new drills (66.10%) and with irrigation/old drills (50.82%). In the groups, where the alveolus had been carried through with new drills without irrigation and old drills without irrigation, it was observed osseous unavailability due to the predominance of osteocytes with pyknotic nucleus and empty lacunae. Those facts demonstrate the cellular degeneration caused by the heat. In this research, we conclude that the external irrigation and the drills cutting power influence in maintenance of the osseous viability. Furthermore, microscopically the bone cells demonstrate morphologic alterations after the frictional heating.
APA, Harvard, Vancouver, ISO, and other styles
18

Barbosa, Bruno Aiello. "Eficácia na remoção da necrose óssea térmica: realizada por implantes osseointegráveis com câmaras coletoras." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/25/25136/tde-11112013-161838/.

Full text
Abstract:
Durante a confecção do alvéolo, promove-se o aumento da temperatura da broca devido à fricção, aquecendo o tecido ósseo adjacente e seus componentes celulares, podendo provocar a Necrose Óssea Térmica. A necrose óssea térmica deteriora a porção orgânica do tecido ósseo (tanto matriz óssea como as células), bem como as células diferenciadas e indiferenciadas presentes na circulação sanguínea e medula óssea local. Alguns trabalhos demonstraram que o aquecimento ósseo acima de 47oC por 1 minuto provoca tal fenômeno. Atualmente existem variações na técnica de perfuração com objetivo de diminuir o grau de aquecimento e aumentar as taxas de sucesso dos tratamentos reabilitadores. Sabemos que nem todos os profissionais são cautelosos em utilizar materiais de qualidade e que mesmo os materiais com qualidade, após repetido uso, perdem a eficácia. Seria ideal que o implante osseointegrável gerenciasse a remoção destas áreas de necrose óssea térmica, independentemente da execução correta da técnica de perfuração e da qualidade das brocas. Com isso, garantiríamos que o tecido ósseo poderia se reparar ao redor dos implantes da melhor maneira possível. Neste trabalho avaliamos a eficácia de 3 modelos de implante com câmaras coletoras funcionais diferentes, em tecido ósseo de minipig. O implante com câmara coletora interna demonstrou-se 37,22% mais eficaz que o implante com câmaras externas e 3 arestas cortantes, quando os alvéolos eram confeccionados sem irrigação e com brocas desgastadas. O implante com câmaras coletoras externas e 4 arestas também demonstrou-se eficaz, porém manteve 83,75% das células viáveis enquanto que no grupo com câmaras internas este resultado foi de 91,39%.
The manufacture of the alveolus can increase the temperature of the drill due to friction heating the adjacent bone tissue and its cellular components, this phenomenon is known by thermal osteonecrosis. The thermal osteonecrosis deteriorates the organic portion of bone (bone matrix and cells), as well as undifferentiated and differentiated cells circulating in the blood and bone marrow. Some studies have demonstrated that bone heating above 47oC for 1 minute causes this phenomenon. Currently there are variations in drilling technique aiming to reduce the heating degree and increase the success rates of rehabilitation treatments. We know that not all professionals are cautious of using quality materials and even the materials with quality after repeated use, lose their effectiveness. Would be ideal that implants manages and removes these areas with thermal osteonecrosis, regardless of the technique of implementing the drilling and the quality of drills. With this, we ensure that bone tissue could possibly repair around implants in the best way. In this study we evaluated the efficacy of 3 implant models with different functional collecting chambers in minipigs bone tissue. The implant with internal collection chamber proved to be 37.22% more effective than the implant with external chambers and three sharp edges, when the alveolus were manufactured without irrigation and uncut drills. The implant with external collecting chambers and four sharp edges also showed an effective but 83.75% of the cells remained viable while in the group with internal chambers this result was 91.39%.
APA, Harvard, Vancouver, ISO, and other styles
19

Markarian, Roberto Adrian. ""Biomecânica da transmissão de cargas a implantes unitários em função dos materiais protéticos: análise fotoelástica e dinâmica"." Universidade de São Paulo, 2005. http://www.teses.usp.br/teses/disponiveis/23/23137/tde-14102005-121119/.

Full text
Abstract:
Em próteses sobre implantes, o recobrimento oclusal com materiais pouco rígidos como os acrílicos, é por vezes utilizado por supostamente reduzir a carga transmitida ao osso, entretanto não existe um consenso na literatura sobre a sua efetividade. O objetivo deste trabalho foi comparar, por análise fotoelástica e dinâmica, a transmissão de forças após a ação de cargas sobre próteses unitárias sobre implantes em função dos materiais protéticos. Confeccionou-se um modelo em resina fotoelástica com anatomia semelhante à região de pré-molares inferiores, contendo um implante de hexágono interno de 3,75 x 11,5 mm. Foram elaboradas três tipos de próteses em materiais com rigidez decrescente: 1- Metálica (alta rigidez); 2- Resina composta (rigidez moderada), 3- Com um disco de EVA interposto com h=2,5 mm (baixa rigidez). Por meio de um polariscópio circular, observou-se qualitativamente a tensão gerada no modelo durante a aplicação de forças axiais de 100 N, em regime compressivo, sobre cada tipo de prótese. Para a análise dinâmica, realizou-se um modelamento físico de cada um dos três sistemas implante-prótese com modelos de Voigt. A partir daí, uma representação matemática dos sistemas foi deduzida e resolvida, levando em consideração as propriedades mecânicas dos diferentes materiais testados, como o módulo de elasticidade (E), o coeficiente elástico (k) e a constante de amortecimento (c). Para representar uma carga mastigatória fisiológica, foi aplicado um pulso de força senoidal com duração de 0,25 s e intensidade máxima de 100 N, segundo a expressão ()) 8 cos( . 50 50 t t f π −=. Observou-se na análise fotoelástica que após a aplicação de 100N, surgiram tensões na região apical e na cervical dos implantes, com intensidade e localização similares entre os três tipos de prótese. A análise dinâmica mostrou que a força de 100N aplicada na prótese é totalmente transmitida ao implante instantaneamente. Os resultados das análises concordam entre si e mostram que não é possível amortecer as forças mastigatórias por meio dos materiais oclusais.
Less rigid oclusal materials such as acrylic resins are often used in prosthesis over implants because they are supposed to diminish the loads transferred to the bone; however there is no scientific evidence to support this theory. The objective of this work was to compare by photoelastic and dynamic analysis the load transfer after oclusal loads over single prosthesis over implants, varying the oclusal materials. A photoelastic model was created, with an anatomy similar to an inferior premolar region. An internal hexagon implant (3,75 x 11,5 mm) was put in this model. Three different types of prosthesis were constructed with decrescent stiffness: 1- Metallic (higher stiffness); 2- Composite resin (moderate stiffness); 3- With an EVA disc interposed (fewer stiffness). By means of a circular polariscope, the stress generated in the model with a compressive axial load of 100 N, was observed for each prosthesis. For the dynamic analysis, a physical modeling of each implant-prosthesis was carried out with Voigt models. After that, a mathematical representation of the systems was deduced and solved, taking into account the mechanic properties of the different materials, like the elastic modulus (E), the elastic coefficient (k) and the damping constant (c). To represent a physiologic masticatory load, a senoidal force was applied, during 0,25 s and maximum load of 100 N, by the expression ()) 8 cos( . 50 50 t t f π −=. With the photoelastic analysis, it was observed that stresses were generated at the apical and cervical regions of implants, with similar intensity and patterns between the three types of prosthesis. The dynamic analysis, showed that the loads applied over the prosthesis are transferred to the implant instantaneously. The results of both anaylis are in agreement that it is not possible to damp masticatory loads by means of occlusal materials.
APA, Harvard, Vancouver, ISO, and other styles
20

Conforte, Jadison Junio. "Efeito do biofilme de Enterococcus faecalis na resistência corrosiva no Titânio submetido a diferentes tratamentos de superfície /." Araçatuba, 2019. http://hdl.handle.net/11449/183065.

Full text
Abstract:
Orientador: Wirley Gonçalves Assunção
Coorientador: Cristiane Duque
Banca: Leonardo Perez Faverani
Banca: Valetin Adelino Ricardo Barão
Resumo: O objetivo desse estudo foi avaliar, in vitro, a corrosão em diferentes superfícies de Titânio comercialmente puro-Grau 4 (Ticp-G4) em função do efeito de biofilme bacteriano de Enterococcus faecalis. 57 discos foram utilizados divididos aleatoriamente de acordo com a superfície (n=19): Grupo I superfície usinada (USI); Grupo II superfície texturizada por duplo ataque ácido (D.A.) e Grupo III superfície texturizada por duplo ataque ácido e jateamento por zircônia (D.A.Zir). Para análise microbiológica (n=9), os discos foram posicionados em placas de 24 poços contendo cultura de Enterococcus faecalis à 1.5 x 105 células/mL em meio BHI caldo e incubados por 168 horas (7 dias) a 37° C. Após este período os discos foram removidos e as bactérias aderidas em sua superfície foram avaliadas por meio de contagem de Unidades Formadora de Colônias/mL (UFC/mL). Para análise corrosiva (n=5), novos espécimes foram inoculados da mesma forma em cultura de E. faecalis e após 7 dias, estes foram destinados ao ensaio eletroquímico por meio de espectroscopia de impedância eletroquímica (EIE), utilizando como eletrólitos BHI e biofilme e BHI caldo estéril. Os resultados foram submetidos à análise estatística: microbiológico (ANOVA com pós teste Tukey; 5%) e ensaio eletroquímico (ANOVA 2 Fatores e pós teste Tukey 5%). Na avaliação da contagem celular bacteriana, somente D.A.Zir (média 34 UFC/ml) diferiu de USI (média 16 UFC/ml) (p = 0,034), mas não de D.A. (24 UFC/ml). Na espectroscopia de impedân... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The objective of this study was to evaluate, in vitro, the corrosion in different surfaces of Titanium commercially pure-Grade 4 (Ticp-G4) as a function of the bacterial biofilm effect of Enterococcus faecalis. 57 disks were randomly divided according to the surface (n = 19): Group I machined surface (USI); Group IIsurface textured by double acid attack (D.A.) and Group III surface textured by double acid etching and zirconia (D.A.Zir). For microbiological analysis (n = 9), the discs were positioned in 24-well plates containing Enterococcus faecalis culture at 1.5 x 10 5 cells / ml in broth BHI medium and incubated for 168 hours (7 days) at 37 ° C. period the discs were removed and the bacteria adhered on its surface were evaluated by means of Colony Forming Units / mL (CFU / mL) counts. For corrosive analysis (n = 5), new specimens were inoculated in the same way in E. faecalis culture and after 7 days, they were destined to the electrochemical test by means of electrochemical impedance spectroscopy (IEE) using BHI and biofilm electrolytes and BHI sterile broth. The results were submitted to statistical analysis: microbiological (ANOVA with Tukey post test, 5%) and electrochemical test (ANOVA 2 Factors and post test Tukey 5%). In the evaluation of bacterialcell count, only D.A.Zir (mean 34 CFU / ml) differed from USI (mean 16 CFU / ml) (p = 0.034), but not D.A. (24 CFU / ml). In electrochemical impedance spectroscopy, for Nyquist and BODE, the D.A.Zir (Biofilm) group showed ... (Complete abstract click electronic access below)
Mestre
APA, Harvard, Vancouver, ISO, and other styles
21

Oh, Tae-Ju. "Histomorphometric comparison of two collagen membranes for the treatment of implant dehiscence defects a thesis submitted in partial fulfillment ... for the degree of Master of Science in Periodontics ... /." 2001. http://catalog.hathitrust.org/api/volumes/oclc/68962592.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
22

Stathis, Konstantinos. "An auger spectroscopic analysis of dental implant surface contaminants a thesis submitted in partial fulfillment ... for the degree of Master of Science in Prosthodontics /." 1997. http://catalog.hathitrust.org/api/volumes/oclc/68799621.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

McCracken, Michael. "Histomorphometric and radiopharmaceutical investigations of the bone integration of implants in vivo laboratory models /." 1999. http://catalog.hathitrust.org/api/volumes/oclc/48208737.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Fialho, Luísa Isabel Serra Glória. "Design of new biocompatible osseointegrated and antimicrobial dental implant." Doctoral thesis, 2021. http://hdl.handle.net/1822/75545.

Full text
Abstract:
Programa Doutoral em Engenharia de Materiais
Como alternativa aos implantes dentários convencionais de Ti, foi realizada uma biofuncionalização de superfícies de Ta por diferentes tratamentos de superfície de modo a aumentar a bioatividade da superfície bem como dotá-la de capacidade bactericida. Para alcançar este design inovador, a estratégia adotada prendeu-se com duas etapas principais: i) desenvolvimento de uma superfície bioativa baseada no efeito sinergético da camada anódica de Ta2O5 com (nano a micro) porosidades e enriquecida por elementos osteocondutores; ii) desenvolvimento do sistema antimicrobiano pela deposição, por pulverização catódica, de NPs de Zn/ZnO na superfície de Ta2O5, com ou sem uma fina camada de carbono. O primeiro tratamento funcional consistiu em duas etapas de anodização. A anodização inicial revelou-se sensível à concentração do eletrólito levando a uma curva j-t instável, ao aumento de temperatura do eletrólito e a uma morfologia final porosa ordenada e homogénea. A segunda anodização teve como finalidade incorporar elementos osteocondutores (Ca; P e/ou Mg) com uma razão de Ca/P biomimética. Duas abordagens foram propostas: anodização e/ ou polarização inversa. Os elementos osteocondutores foram incorporados na camada porosa de Ta2O5 sem comprometer a morfologia, porém a secção transversal das superfícies revelou uma estrutura lamelar inviável para aplicações biomédicas. Numa segunda abordagem, foi adotado o processo de oxidação por micro-arco onde foi possível otimizar uma estrutura (micro+nano) -porosa de Ta2O5 com Ca e P. Posteriormente, NPs de Zn (Zn/ZnO – core/shell) foram depositadas por pulverização catódica nas superfícies bioativas com (ou sem) uma camada adicional de carbono para controlar a libertação dos iões Zn²⁺. A adesão celular inicial foi garantida em todas as superfícies, destacando-se a superfície de Ta2O5 com NPs e a camada de carbono, que traduziu a maior taxa de proliferação celular. As duas superfícies com NPs apresentaram atividade antibacteriana contra S. aureus e a maior inibição das bactérias sésseis foi observada na superfície com as NPs Zn/ZnO sem a camada de carbono. Graças ao excelente desempenho in vitro das superfícies de Ta nanoestruturadas com elementos osteocondutores, este trabalho é um progresso na estratégia para desenvolver uma nova geração de implantes dentários simultaneamente capazes de promover a osteointegração e prevenir infeções implantares.
As alternative to the conventional Ti dental implants surfaces, Ta surface biofunctionalization was investigated using different surface treatments in order to enhance the surface bioactivity as well as endow it with bactericidal ability. To achieve this innovative design, the adopted strategy was accomplished in two main steps: i) development of a bioactive surface based on the synergetic effect of anodic Ta2O5 with multilevel porosity (nano to micro) with osteoconductive elements incorporated; ii) development of an antimicrobial delivery system by deposition, by magnetron sputtering, of Zn/ZnO nanoparticles deposited onto the anodic Ta2O5 structured surface with or without an additional thin carbon layer. The first functional treatment consisted of two anodization steps. The initial anodization-step was sensible to the electrolyte concentration leading to an unstable j-t curve and to a strong electrolyte temperature increase and a quite ordered and homogeneous porous nanopattern. A second anodization was carried out to obtain a porous structure enriched with osteoconductive elements (Ca, P and/or Mg), attaining a biomimetic Ca/P ratio. Two approaches were proposed: anodization and/or reverse polarization. The osteoconductive elements were successfully incorporated onto the porous Ta2O5 layer without compromising the nanostructure, however the cross-sectional analysis revealed an unsuitable lamellar structure for biomedical applications. As second approach, micro-arc oxidation process was adopted where it was possible to optimize a (micro+nano)porous CaP-containing Ta2O5 surface. Afterwards, Zn NPs (Zn/ZnO core-shell structure) were deposited by magnetron sputtering onto the bioactive surfaces with (or without) an additional carbon layer, for Zn²⁺ ions release control. The initial osteoblasts adhesion was ensured on all surfaces, but the porous Ta2O5 surface with the Zn/ZnO NPs and the carbon layer stood out, which also translated to a higher proliferation rate. Both Zn-containing surfaces presented antibacterial activity against S. aureus and the greatest sessile bacteria inhibition was observed on the surface with the Zn/ZnO NPs without the carbon layer. Due to the excellent in vitro performance of the nanostructured Ta surface with osteoconductive elements, this work is clearly a progress on the strategy to develop a new generation of dental implants that can simultaneously promote osseointegration and prevent implant’s infection.
Agradeço os apoios financeiros recebidos no âmbito do projeto HEALTHYDENT, POCI-01-0145-FEDER-030708
APA, Harvard, Vancouver, ISO, and other styles
25

Humphries, Robert M. "The accuracy of master casts fabricated from transfer impressions using the Branemark Osseointegrated Implant System a thesis submitted in partial fulfillment ... prosthodontics ... /." 1988. http://catalog.hathitrust.org/api/volumes/oclc/68788768.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles