Contents
Academic literature on the topic 'Micromuscles artificiels'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Micromuscles artificiels.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Micromuscles artificiels"
Liu, Shuangping, Zhenwei Yao, Kevin Chiou, Samuel I. Stupp, and Monica Olvera de la Cruz. "Emergent perversions in the buckling of heterogeneous elastic strips." Proceedings of the National Academy of Sciences 113, no. 26 (June 14, 2016): 7100–7105. http://dx.doi.org/10.1073/pnas.1605621113.
Full textMaziz, Ali, Cédric Plesse, Caroline Soyer, Eric Cattan, and Frédéric Vidal. "Top-down Approach for the Direct Synthesis, Patterning, and Operation of Artificial Micromuscles on Flexible Substrates." ACS Applied Materials & Interfaces 8, no. 3 (January 11, 2016): 1559–64. http://dx.doi.org/10.1021/acsami.5b09577.
Full textYang, Xiufeng, Longlong Chang, and Néstor O. Pérez-Arancibia. "An 88-milligram insect-scale autonomous crawling robot driven by a catalytic artificial muscle." Science Robotics 5, no. 45 (August 19, 2020): eaba0015. http://dx.doi.org/10.1126/scirobotics.aba0015.
Full textDissertations / Theses on the topic "Micromuscles artificiels"
Gaudin, Vincent. "Contribution à l'étude de micromuscles artificiels activables par pression osmotique et implantables en milieu biologique." Phd thesis, Grenoble 1, 2007. http://www.theses.fr/2007GRE10057.
Full textThis work is a contribution to the development of artificial micromuscles lays on an innovating “in-vivo” way of energy conversion. The idea is to use the osmotic process to convert a chemical energy into a mechanical one. This study is generic as the potential biomedical applications might be numerous; it is based on the design of an inflatable semipermeable membrane structure (joined osmotic) intended to avoid endoleaks occurring from abdominal aorta aneurysm endoprosthesis. After presenting the osmotic phenomenon and the considered applications, the study breaks up into two parts. The first part carries on the osmo-mechanical characterization of the osmotic system water/cellulose-acetate membrane/saccharose. This was made possible thanks to the development of original experimental devices. Regarding the targeted range of use, the membrane’s mechanical behavior is mainly elastoplastic and its permeability strongly depends on its strain state. In the second part, we develop a numerical model of the contact area between the aneurysm neck and the endoprosthesis equipped with an inflatable joint. The modeling of the membrane joint is based on the results of the first part. The mechanical behaviors of the endoprosthesis and the aorta are modelled on the basis of literature’s result, respectively by a simple linear elastic isotropic law and an isotropic hyperelastic potential of Rivlin series. A parametric study then underlines the feasibility of this endoprosthesis and the influences of few design parameters on its performances
Gaudin, Vincent. "Contribution à l'étude de micromuscles artificiels activables par pression osmotique et implantables en milieu biologique." Phd thesis, 2007. http://tel.archives-ouvertes.fr/tel-00169431.
Full textAprès l'exposé du phénomène d'osmose et de l'application envisagée, l'étude se décompose en deux parties.
• La première partie porte sur la caractérisation osmo-mécanique du système osmotique eau/membrane d'acétate de cellulose/saccharose. Des dispositifs expérimentaux originaux ont été mis en place. Dans le domaine d'utilisation envisagé, la membrane présente un comportement mécanique principalement élasto-plastique et sa perméabilité dépend fortement de son état de déformation.
• Dans la seconde partie, un modèle numérique de la zone de contact entre le collet de l'anévrisme et l'endoprothèse munie d'un joint gonflable est mis en place. La modélisation du joint membranaire s'appuie sur les résultats de la première partie. Les comportements mécaniques de l'endoprothèse et de l'aorte sont modélisés sur la base de résultats de la littérature respectivement par une simple loi isotrope élastique linéaire et un potentiel hyperélastique isotrope en série de Rivlin. Une étude paramétrique permet alors de souligner la faisabilité de cette endoprothèse et l'influence de quelques paramètres de conception sur ses performances.