Dissertations / Theses on the topic 'Materiali Dentari'

To see the other types of publications on this topic, follow the link: Materiali Dentari.

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Materiali Dentari.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Casella, Giuseppina. "Ricerche in vitro sui materiali dentari nella odontoiatria riabilitativa in pazienti sottoposti a terapia ortognatodontica." Doctoral thesis, Università di Catania, 2012. http://hdl.handle.net/10761/1130.

Full text
Abstract:
Le ricerche in vitro sui materiali dentari utilizzati nell Odontoiatria Riabilitativa sono state realizzate al fine di valutare le proprietà meccaniche di resine composite, adesivi smalto-dentinali e cementi endodontici di diverso spessore foto polimerizzati con due differenti lampade: un alogena di nuova generazione (Astralis 10 Ivoclar Vivadent) e una lampada LED (MiniLED Satelec), adoperate in modalità continua ad alta intensità di potenza ( > 1000 mW/cm2) e in modalità incrementale per tempi di esposizione di 10 e 20 secondi. Su campioni di opportuna geometria sono stati eseguiti test meccanici di compressione, flessione, durezza Vickers, usura e usura dopo trattamenti con acidi (acido orto fosforico al 36%, perossido di idrogeno al 10%, perossido di idrogeno al 20%, permanganato di potassio al 10%, etossido di sodio al 10%), e analisi al microscopio elettronico a scansione (SEM). L analisi statistica è stata effettuata utilizzando il test ANOVA a effetti fissi a due vie per campioni dipendenti (P < 0,05). I risultati delle prove hanno indicato che la sorgente alogena utilizzata nella sperimentazione permette di raggiungere gradi di conversione maggiori e in tempi più brevi rispetto a quella LED. È stato inoltre possibile definire le condizioni operative ottimali, in termini di tempo d esposizione e di spessore del campione, per ottenere materiali reticolati omogeneamente. I valori di durezza Vickers sia della superficie superiore, direttamente esposta alla fonte di luce, sia di quella inferiore hanno permesso di valutare il grado di polimerizzazione dei campioni irradiati per tempi e con modalità differenti. I valori di compressione hanno dimostrato che a parità di tempo di esposizione e di modalità di rilascio della luce, la sorgente luminosa adoperata influenza la resistenza a compressione dei materiali dentari analizzati. I materiali dentari contenenti componenti ibride e microibride testati rispondono meglio all azione della luce alogena. La componente nano ceramica risulta più resistente alla compressione se polimerizzata con sorgente LED. Utilizzando una lampada LED si è dimostrato che è consigliabile non superare per ogni apporto i 2 mm di spessore e prolungare i tempi di foto polimerizzazione, in modo da migliorare le caratteristiche meccaniche dei materiali dentari, specie quando è necessario foto polimerizzare a distanza e si opera su pazienti disfunzionali, dovendo riabilitare aree sottoposte a notevoli stress. I valori di flessione osservati tra i materiali dentari testati hanno rivelato che la sorgente alogena, utilizzata per identici tempi e con uguale modalità, garantiscono maggiori valori di resistenza a flessione rispetto alla LED. La completa polimerizzazione dei materiali testati, indicata dai valori di resistenza a flessione dipende comunque più dallo spessore dei materiali che dai tempi di irraggiamento.I valori di usura e usura dopo trattamenti con acidi (acido orto fosforico al 36%, perossido di idrogeno al 10%, perossido di idrogeno al 20%, permanganato di potassio al 10%, etossido di sodio al 10%) osservati tra i materiali dentari testati hanno rivelato che la sorgente LED, utilizzata per identici tempi e con uguale modalità, garantisce maggiori valori di resistenza a usura rispetto alla sorgente alogena. È stato così osservato che i materiali dentari esaminati presentano comportamenti alquanto differenti legati presumibilmente alla loro composizione di base.
APA, Harvard, Vancouver, ISO, and other styles
2

Diolosà, Marina. "Development of a new nano-engineered biopolymer-based dental adhesive system." Doctoral thesis, Università degli studi di Trieste, 2015. http://hdl.handle.net/10077/11136.

Full text
Abstract:
2013/2014
Lo scopo di questa tesi di dottorato è stato studiare l'effetto sulla durabilità dell’interfaccia adesiva del chitosano, modificato con gruppi metacrilici, con l’obiettivo di migliorare l'affidabilità clinica dei restauri dentali. Attualmente, la ricerca in questo settore mira ad aumentare la durata nel tempo del legame resina-dentina. Questa ricerca propone un nuovo concetto di sistema adesivo bi-funzionale basato su un biopolimero naturale in grado di creare doppia reticolazione covalente. Il chitosano è un polimero biocompatibile e non tossico. In questo studio è stato ipotizzato che il chitosano modificato con gruppi metacrilici sia in grado di legarsi covalentemente alla resina dei restauri dentale e, grazie alla presenza di cariche positive residue sul polisaccaride, di interagire elettrostaticamente con la dentina demineralizzata. Il Chitosano metacrilato è stato introdotto nel primer di un sistema adesivo sperimentale etch&rinse a tre passaggi per valutarne la forza di legame alla dentina. Le prove d’invecchiamento sono state condotte utilizzando due metodiche: invecchiamento statico e dinamico. Il secondo metodo simula la presenza del sistema adesivo nell’ambiente orale, sottoposto sia a carico masticatorio, che a stress termici. Le metodiche d’invecchiamento sono necessarie per valutare la stabilità nel tempo dei restauri dentali. L'introduzione del chitosano modificato con gruppi metacrilici nel primer di un sistema adesivo etch&rinse ha determinato: buoni valori di adesione dopo 24 ore (T0 μTBS); (2) buona stabilità dello strato ibrido quando sottoposto a simulazione meccanica della masticazione e stress termici (TCS μTBS). In sintesi, la prima parte di questa tesi di dottorato ha avuto lo scopo di esaminare lo stato dell'arte dei materiali dentali attualmente utilizzati in odontoiatria e il problema più importante in odontoiatria restaurativa: la degradazione dell'interfaccia adesiva. La seconda fase di questa ricerca è stata dedicata al trovare la formulazione ottimale di un sistema adesivo contenente chitosano modificato con gruppi metacrilici. Diverse formulazioni sono state testate e il sistema sperimentale identificato come A3* è stato considerato la migliore formulazione utilizzabile come sistema adesivo. Questa formulazione è stata poi nominata Chit-MA70. Sono stati eseguiti diversi test per valutare le caratteristiche dell’adesivo sperimentale, compresi test meccanici (test di microtensile). L'espressione del nanoleakage è stata valutata utilizzando la microscopia ottica e la microscopia elettronica a scansione (SEM). Per valutare la sostantività del chitosano sullo strato adesivo, il polimero è stato marcato con fluoresceina e i campioni sono stati osservati al microscopio confocale a scansione laser (CLSM). Nella fase finale di questo studio sono stati condotti test di citotossicità per valutare l'effetto del sistema adesivo Chit-MA70 sulla vitalità cellulare. Le prove eseguite su fibroblasti gengivali hanno rivelato una tossicità ridotta, se non praticamente assente, del sistema adesivo contenente chitosano metacrilato. Considerando i buoni risultati di questo studio, il chitosano modificato con gruppi metacrilici è stato proposto come componente di un sistema adesivo sperimentale. I risultati ottenuti utilizzando questo nuovo sistema adesivo sono stati rivendicati in un brevetto (febbraio 2014) e pubblicati in Biomacromolecules nel mese di ottobre (2014).
The purpose of this thesis was to investigate the effect of a methacrylate-modified chitosan on the durability of adhesive interfaces to improve the clinical performance of dental restorations. Current research in this field aims at increasing the resin-dentin bond durability. The aim of this project was the development of an innovative nano-engineered biocompatible dental adhesive system capable to form covalent chemical bonds with both the dentin collagen and the resin-based restorative materials. This research proposes a new concept of bi-functional reactive adhesive system based on a natural biopolymer capable to create double covalent reticulation. Chitosan is a biocompatible, biodegradable and non-toxic biopolymer. In the present work, chitosan was modified with methacrylate moieties and a physical-chemical characterization was carried out. This research speculated that the modified chitosan was able to covalently bind to the restorative resin and, due to the presence of residual positive charges on the polysaccharide, to electrostatically interact with the demineralized dentine. Chitosan bearing methacrylate groups was blended within the primer of a three- step etch&rinse experimental dentine bonding system to assay its bonding ability to dentine. Additionally, bonded interfaces were challenged with a chewing simulation associated with thermo cycling to assay their stability over time. The introduction of chitosan-modified monomers within the primer of an experimental three-step etch-and-rinse adhesive, improved (1) immediate bond strength (T0 μTBS); (2) stability of the hybrid layer after simulated chewing and thermo cycling (TCS μTBS). In summary, the first part of this PhD thesis aimed to review the state of the art of dental materials currently used in dentistry and the most important problem in restorative dentistry: the degradation of bonded interface focusing on the fundamental processes that are responsible for the degradation of the adhesive interface. The second part of this doctoral thesis was dedicated to find the optimal formulation of a chitosan–containing dental adhesive system. Several formulations were were tested and the one identified as A3* was considered the best formulation to be used as an adhesive system. This formulation was then named Chit-MA70. Several tests were carried out, including mechanical tests such as the microtensile bond strength test. The nanoleakage expression was evaluated using optical microscopy and scanning electron microscopy. The evaluation of the substantivity of chitosan on the adhesive layer was evaluated by labeling the methacrylate-modified chitosan, contained into the primer, with fluorescein and then observing the samples by confocal laser scanning microscopy. In the end, cytotoxicity tests were performed to evaluate the effect on cell viability of the adhesive system Chit-MA70. Tests carried out on gingival fibroblasts revealed a reduced if not practically absent toxicity of the adhesive system containing methacrylate-modified chitosan. Considering the good results of this study, the methacrylate-modified chitosan has been proposed as a component of a novel adhesive system. The findings on this new dental adhesive with methacrylate-modified chitosan were claimed into a patent in February 2014 and published in Biomacromolecules in October 2014.
XXVII Ciclo
1986
APA, Harvard, Vancouver, ISO, and other styles
3

Fonseca, Johnson Campideli. "Influencia das temperaturas de cocção de ceramica na resistencia a tração e dureza Vickers do titanio comercialmente puro fundido." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289196.

Full text
Abstract:
Orientador : Guilherme Elias Pessanha Henriques
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T02:46:58Z (GMT). No. of bitstreams: 1 Fonseca_JohnsonCampideli_D.pdf: 3777046 bytes, checksum: af3365185db79e8a274340afe4c58f00 (MD5) Previous issue date: 2005
Resumo:A utilização das ligas de metais não nobres para metalocerâmica tem aumentado com o passar do tempo devido às propriedades mecânicas e baixo custo das mesmas. O titânio tornou-se popular devido à sua excelente biocompatibilidade e propriedades mecânicas favoráveis. Apesar de tais vantagens, as informações sobre a influência dos ciclos de cocção das cerâmicas na dureza Vickers e resistência à tração são escassas. O objetivo do presente estudo foi: 1) avaliar a influência do ciclo de cocção da cerâmica (Vitatitankeramic) na dureza Vickers, bem como na resistência à tração (resistência à tração máxima, resistência à tração na ruptura e alongamento) do titânio comercialmente puro grau 2 fundido; 2) determinar o modo de falha nas superfícies fraturadas por meio de inspeção visual e caracterização por imagens obtidas com microscopia eletrônica de varredura (MEV). A dureza com penetrador Vickers foi medida em corpos-de-prova fundidos em formato de disco (3mm de espessura e 6mm de diâmetro) com carga de 9,08N e 5 segundos (HV1) de tempo de permanência. Os corpos-de-prova foram divididos nos seguintes grupos (n=5): DIN (sem ciclo de cocção), DBO (ciclo do ERQGHU), DOP (ciclos do ERQGHU+opaco), DDE (ciclos do ERQGHU+opaco+dentina) e DGL (ciclos do ERQGHU+opaco+dentina+JOD]H). Para o teste de resistência à tração foram utilizados corpos-de-prova de acordo com a norma E8M da ASTM e especificação número 5 da A.D.A. O teste foi realizado em uma máquina de ensaios mecânicos (MTS 810) com velocidade de deslocamento do atuador de 1mm/min. Os grupos (n=10) para o teste de resistência à tração foram divididos em TIN (sem ciclo de cocção), TBO (ciclo do ERQGHU), TOP (ciclos do ERQGHU+opaco), TDE (ciclos do ERQGHU+opaco+dentina) e TGL (ciclos do ERQGHU+opaco+dentina+JOD]H). A análise de falha foi feita por avaliação macroscópica visual e caracterização com MEV para determinar o modo predominante de fratura. Os valores originais de dureza Vickers e resistência à tração foram submetidos ao teste de análise de variância e as médias comparadas pelo teste de Tukey com 5% de nível de probabilidade. Os valores médios de dureza Vickers foram: 187,00±5,91 para DIN, 206,44±3,37 para DBO, 199,55±3,15 para DOP, 202,05±1,78 para DDE e 207,10±6,87 para DGL, com diferença significativa apenas entre o grupo DIN e os outros grupos submetidos aos ciclos de cocção da cerâmica. Os valores médios de 20 resistência máxima à tração (MPa) foram 494,05±54,4 para TIN, 511,28±51,76 para TBO, 505,46±44,76 para TOP, 481,99±68,66 para TDE e 493,13±33,17 para TGL. Os valores médios de resistência à tração na ruptura (MPa) foram: 409,24±58,5 para TIN, 411,45±42,62 para TBO, 407,06±35,83 para TOP, 390,26±55,96 para TDE e 395,5±26,35 para TGL. Os valores médios de alongamento (mm) foram: 3,07±1,04 para TIN, 3,01±0,93 para TBO, 2,72±0,44 para TOP, 3,05±0,86 para TDE e 2,72±0,89 para TGL. Não foram encontradas diferenças significativas nos grupos quanto à resistência máxima à tração, resistência à tração na ruptura e alongamento. A dureza Vickers após os ciclos de cocção da cerâmica exibiu diferença significativa em relação ao grupo DIN. A resistência à tração máxima, resistência à tração na ruptura e alongamento não foram influenciados pelos ciclos de cocção de forma significativa. A fratura dúctil foi predominante em todos os grupos, com presença de dimples na superfície de fratura
Abstract: The application of base metal alloys in metal-ceramic crowns has increased in the past because of their mechanical properties and low cost. Titanium has become popular due to its excelent biocompatibility and favorable mechanical properties. Despite its advantages, information about the influence of porcelain firing cycle on the Vickers hardness and tensile strenght is scarce. The aim of this study was: 1) to evaluate the porcelain firing cycle (Vitatitankeramic) influence on Vickers hardness and tensile strength, ultimate tensile strength and elongation of cast grade 2 commercially pure titanium; 2) to determine the mode of failure in fractured surfaces by macroscopic visualization and characterisation by scanning electron microscope (SEM) images. The hardness was measured with Vickers hardness tester in cast disc specimens (3mm in thickness and 6mm in diammeter) with 9,08 N of load and 5 seconds (HV1) for maintenance time. The specimens were divided into the following groups (n=5): DIN (without firing cycle), DBO (bonder cycle), DOP (bonder + opaque), DDE (bonder+opaque+dentin cycles) and DGL (bonder+opaque+dentin+glaze cycles). For the tensile test, specimens according with the ASTM E8M and specification 5 A.D.A. were used. The test was performed in a mechanical testing machine (MTS 810) with a crosshead speed of 1mm/min.. For tensile test the groups (n=10) were divided into TIN (without firing cycle), TBO (bonder cycle), TOP (bonder + opaque), TDE (bonder+opaque+dentin cycles) and TGL (bonder+opaque+dentin+glaze cycles). The failure analysis was made by visual inspection and characterisation with SEM to determine the predominant fracture mode. The original values of Vickers hardness and tensile strength were subjected to analysis of variance and the mean values were subjected to Tukey's test set at 5% probability level. The mean values of Vickers hardness were: 187.00±5.91 to DIN, 206.44±3.37 to DBO, 199.55±3.15 to DOP, 202.05±1.78 to DDE and 207.10±6.87 to DGL, with significant difference only between the DIN and the other groups submitted to the firing cycles. The mean values of tensile strength (MPa) were 494.05±54.4 to TIN, 511.28±51.76 to TBO, 505.46±44.76 to TOP, 481.99±68.66 to TDE and 493.13±33.17 to TGL. The ultimate tensile strength (MPa) mean values were: 409.24±58.5 to TIN, 411.45±42.62 to TBO, 407.06±35.83 to TOP, 390.26±55.96 to TDE and 395.5±26.35 to TGL. The values of elongation values (mm) were: 3.07±1.04 to TIN, 3.01±0.93 to TBO, 2.72±0.44 to TOP, 3.05±0.86 to TDE and 2.72±0.89 to TGL. No significant differences were found among groups regarding the tensile strength, ultimate tensile strength and elongation. The Vickers hardness after porcelain firing cycles was significantly different of DIN group. However, the tensile strength, ultimate tensile strength and elongation were not influenced by porcelain firing. Ductile fractures were predominant in all the experimental groups with the presence of dimples
Doutorado
Materiais Dentarios
Doutor em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
4

Melo, Renata Marques de [UNESP]. "Efeitos do tipo de sistema adesivo e região do dente sobre a resistência adesiva à dentina." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/113977.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-06-13Bitstream added on 2015-01-26T13:30:28Z : No. of bitstreams: 1 000326687.pdf: 2821504 bytes, checksum: 1d66d1ded90d9d6ea873a9687a44bde1 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Este estudo foi realizado no intuito de avaliar a resistência de união à dentina coronária e do canal radicular com dois sistemas adesivos de condicionamento total (dois e três passos) e um sistema autocondicionante. Os canais de trinta incisivos e caninos humanos superiores foram instrumentados e preparados com brocas. Os pinos usados na cimentação foram réplicas em cimento resinoso dual Duo-link do pino Aestheti Plus #2. Assim, constituíram-se três grupos (n = 10), segundo o sistema adesivo utilizado: condicionamento total três passos (CT3) - AII-Bond 2 + pino em cimento resinoso (pcr)+ Duo-link (DI); condicionamento total 2 passos (CT2) - One-Step Plus + pcr + DI; autocondicionante (AC) - Tyrian/One-Step Plus+ pcr + DI. Apôs a cimentação, foram obtidas oito secções transversais (1,5mm), a partir de 4mm acima da JEC até 4mm aquém do ápice do canal, envolvendo dentina coronária e radicular. As secções foram submetidas ao ensaio de push-out em máquina de ensaio universal EMIC (1 mm.min-1). Os dados de resistêncía adesiva foram analisados com o teste ANOVA de dois fatores de medidas repetidas (α<0,05). Foi observado que o efeito interação foi estatisticamente significante, isto é, o relacionamento entre os adesivos não foi o mesmo para as diferentes regiões. Comparando-se as médias obtidas com os adesivos em cada região (Tukey; α<0,05), observou-se que o CT3 (média± desvio padrão: 5,22 ± 1,70) foi superior ao CT2 (2,60 ± 1,74) e ao AC (1,68 ± 1,85). Para as condições estudadas, obteve-se melhor adesão à dentina com a utilização do sistema adesivo de condicionamento total com três passos, sobretudo na região coronária
This study aimed to evaluate lhe bond strengths between two total etching adhesive systems and (two and three steps) anda self-etching system to coronal and root canal dentin. The root canal of thirty human anterior teeth were endodontically instrumented and prepared with specific burs. Aestheti Plus #2 posts were duplicated in dual resin cement (Duo-link) and three groups (n=10) were formed, according to the adhesive sysfem used: 3 steps total etching adhesive system (3TE) - All-Bond 2 + resin cement post (rcp) + Duo-link (DI); 2 steps total etching adhesive system (2TE) - One-Step Plus + rcp + DI; sef-etching system (SE) Tyrian/One-Step Plus + rcp +DI. Following cementation, the teeth were cut transversally in eight sections (1,5mm), from the CEJ to 4mm above the canal apex. The sections were subjected to the push-out test in a universal testing machine (1mm.min-1). The data of bond strength were statistically analyzed with 2-way Anova of repeated measures (α<0.05), which showed that the interaction effect was significant. This meant that the relationship between the adhesives was not the same depending on the tooth region. Regarding the adhesive factor'' the comparison of means with Tukey test (α<0.05) showed that 3TE (mean ± standard deviation: 5,22 ± 1,70) was statistically superior to 2TE (2,60 ± 1,74) and SE (1,68 ± 1,85). Under the conditions of the present study, the three step total etching system had the highest bond strengths to dentin, especially in the coronal region
APA, Harvard, Vancouver, ISO, and other styles
5

Hermann, Caio. "Efeito da escovação mecanica e da termociclagem sobre dureza e rugosidade superficiais de reembasadores resilientes." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289925.

Full text
Abstract:
Orientador: Marcelo Ferraz Mesquita
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T03:47:30Z (GMT). No. of bitstreams: 1 Hermann_Caio_M.pdf: 1426714 bytes, checksum: 9b5d60e0226de3bf4200bec3b2f9f1c7 (MD5) Previous issue date: 2005
Resumo: Este trabalho teve como objetivo avaliar o efeito da escovação mecânica e termociclagem sobre dureza e rugosidade superficiais de três materiais reembasadores resilientes considerados definitivos, dois à base de silicone, um auto (Sofreliner MS) e outro termopolimerizável (Molloplast-B), além de um à base de resina acrílica autopolimerizável (Dentuflex). Para a confecção das amostras, foram utilizadas matrizes de silicone polimerizado por reação de condensação incluídas em muflas, obtendo um molde impresso no gesso posteriormente preenchido com os materiais resilientes. Foram confeccionadas 60 amostras, submetidas à leitura de rugosidade superficial num rugosímetro SURFCORDER SE 1700 (Kosaka Laboratory) e à leitura de dureza num durômetro Shore A (GS ¿ 709 Teclock, Osaka, Japão). Em seguida as amostras foram separadas em dois grupos, onde metade foi submetida ao ensaio de termociclagem numa máquina MSCT ¿ 3 PLUS regulada em 2.000 ciclos com banhos alternados de 60 segundos a 5±1oC e 55±1oC e a outra metade ao ensaio de escovação mecânica numa máquina MSEt, seguida de termociclagem. O ensaio de escovação foi executado sob carga estática de 200 g, com movimentos lineares, totalizando 30.000 ciclos, onde uma solução de dentifrício contendo água era liberada a cada 1 minuto sobre as amostras. Após os ensaios, foram executadas novas leituras de dureza e rugosidade superficial. Os valores obtidos foram submetidos à análise de variância em parcelas subdivididas no tempo, seguida do teste de Tukey em nível de 5% de significância. O material Dentuflex apresentou os maiores valores médios de rugosidade e dureza iniciais, seguidos do Molloplast-B e Sofreliner MS. Após termociclagem, os materiais Dentuflex e Sofreliner MS apresentaram aumento estatisticamente significante da dureza. Após escovação, o material Dentulfex apresentou diminuição nos valores de rugosidade e o Sofreliner MS aumento, ambos estatisticamente significantes. Após a escovação seguida de termociclagem, todos os materiais apresentaram valores de rugosidade estatisticamente semelhantes entre si, provavelmente devido ao polimento do material Dentuflex, abrasão do Sofreliner MS e preservação das características do Molloplast-B
Abstract: The aim of this study was to evaluate the effect of mechanical brushing and thermocycling on hardness and roughness of three resilient definitive lining materials: 1) auto (Sofreliner MS), 2) heat-polymerized (Molloplast-B) silicone bases; and 3) auto-polymerized plasticized acrylic resin (Dentuflex). To prepare the samples, silicone rubber matrixes were made and placed in a flask to obtain a cast pressed mold, and then filled with resilient lining materials, handled according to the manufacturer¿s directions. All samples were submitted to surface roughness readings in a roughness readings machine (SURFCORDER SE 1700 ¿ Kosaka Laboratory) and hardness readings in a Shore A durometer (GS ¿ 709 Teclock, Osaka, Japan). After the readings, the samples were assigned into 6 groups of 10 each, half of which were submitted to thermocycling treatment in a thermal cycler machine (MSCT ¿ 3 PLUS) for 2.000 cycles at temperatures ranging from 5±1oC to 55±1oC and a 60-second dwell time. The other half was submitted to a mechanical brushing simulation in an MSEt brushing machine followed by thermocycling. The samples were submitted to 30.000 strokes with linear brushing movements, under a 200 g static load pressure. Toothpaste solution was injected every one-minute break. Then new readings of hardness and roughness were done, and the values were submitted to variance analysis test followed by Tukey test, with 5% of significance. Dentuflex showed the highest initial values for both roughness and hardness, followed by Molloplast-B and Sofreliner MS. After thermocycling, Dentuflex and Sofreliner-MS showed a statistically significant increase in hardness values. After mechanical brushing, Dentuflex showed a decrease and Sofreliner MS an increase in roughness values. After mechanical brushing followed by thermocycling, all materials showed similar roughness values (statistically significant), probably due to the Dentuflex polished surface, the Sofreliner MS abrasion and the remained features of the Molloplast-B
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
6

Oliveira, Luciana Valadares. "Efeito da escovação mecanica e de agentes quimicos de limpeza de proteses sobre as caracteristicas superficiais de materiais reembasadores resilientes." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289926.

Full text
Abstract:
Orientador: Marcelo Ferraz Mesquita
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T03:56:46Z (GMT). No. of bitstreams: 1 Oliveira_LucianaValadares_M.pdf: 2328929 bytes, checksum: d3dcd162bfa4e1648664f19245daaffd (MD5) Previous issue date: 2005
Resumo: O objetivo deste trabalho foi avaliar o efeito da escovação mecânica e de agentes de limpeza sobre as características superficiais de materiais reembasadores resilientes. Foram utilizados os materiais Luci Sof (Dentsply), Molloplast-B (Dentax) e Sofreliner (Tokuyama), os agentes de limpeza Hipoclorito de Sódio a 0,5% (Medicinallis-Fármacia de Manipulação-SP-BR) e Efferdent (Warner-Lamber Co-EUA), a escova dental extra macia Johnson & Johnson Reach Professional (Johnson & Johnson Industrial LTDA.) e dentifrício Sorriso Dentes Brancos (Kolynos do Brasil). Foram confeccionadas 30 amostras de cada material, a partir da moldagem do dispositivo porta matriz da máquina de ensaio de escovação mecânica, com 25mm de comprimento X 14mm de largura X 3mm de espessura. Dez amostras de cada material foram submetidas à escovação mecânica e 20 imersas em agente de limpeza. A escovação mecânica foi realizada na máquina MSEt (Máquina de Simulação de Escovação), com velocidade de 5 movimentos por segundo (20.000 ciclos). Foram utilizados 2 agentes de limpeza: 1) Hipoclorito de Sódio a 0,5% a 37 + 1ºC, durante 20 minutos; 2) Efferdent, a 37 + 1ºC, durante 15 minutos. Após as imersões, as amostras foram lavadas e imersas em água destilada, a 37 ± 1ºC, pelo período restante das 24 h. Esse processo foi repetido 8 vezes por dia, durante 90 dias (720 ciclos). A rugosidade superficial, dureza Shore A e observação em microscópio eletrônico de varredura foram avaliadas antes e após os métodos de higienização. A rugosidade foi avaliada em rugosímetro Surfcorder SE 1700 (Kosaka ¿ Laboratory Ltda.); o ensaio de dureza Shore A em durômetro modelo GS-709 (Teclock-Japão), com aplicação de carga de 10N durante 1 segundo; a microscopia eletrônica de varredura em microscópio modelo JSM 5600 PV (JEOL-Japão), onde foi observada a morfologia superficial de amostras representativas de cada tratamento. Os resultados obtidos foram submetidos aos Testes de Wilcoxon-Mann-Whitney e de Kruskal-Wallis (5%). A escovação aumentou significantemente os valores de rugosidade dos materiais. Luci Sof (Ra=0,74m), Molloplast-B (Ra=1,28m) e Sofreliner (Ra=3,18m) apresentaram diferença estatisticamente significante entre si. O tratamento em Efferdent promoveu diminuição significante dos valores de rugosidade de Luci Sof e Sofreliner. Após o tratamento, os materiais não apresentaram diferença estatisticamente significante entre si (Luci Sof Ra=0,32m; Molloplast-B Ra=0,32m; Sofreliner Ra=0,36m). A imersão em Hipoclorito promoveu diminuição significante os valores de rugosidade dos materiais. Luci Sof (Ra=0,29m) e Molloplast-B (Ra=0,27m) e Molloplast-B e Sofreliner (Ra=0,17m) não apresentaram diferença estatisticamente significante entre si. A escovação diminuiu os valores de dureza significantemente de Molloplast-B (35,10), mas não alterou esses valores de Luci Sof (43,80) e Sofreliner (27,10). Após a escovação, os materiais apresentaram diferença estatisticamente significante entre si. A imersão em Efferdent diminui significantemente os valores de dureza dos materiais. Após o tratamento, Molloplast-B (25,70) e Sofreliner (25,75) não apresentaram diferença estatisticamente significante entre si, mas diferiram de Luci Sof (36,65). A imersão em Hipoclorito diminui significantemente os valores de dureza de Molloplast-B e Sofreliner, e não alterou para Luci Sof. Após o tratamento, Molloplast-B (28,85) e Sofreliner (26,00) não apresentaram diferença estatisticamente significante entre si, mas diferiram de Luci Sof (43,80). A escovação mecânica foi o tratamento que promoveu os maiores valores de rugosidade superficial para todos os materiais avaliados. Após a escovação, todos apresentaram valores estatisticamente diferentes entre si, na ordem crescente: Luci Sof, Molloplast-B e Sofreliner. Os tratamentos de imersão promoveram a diminuição dos valores de rugosidade superficial apresentados pelos materiais Luci Sof e Molloplast-B, e elevação para o material Sofreliner quando imerso em Efferdent. A escovação diminuiu o valor mediano de dureza do material Molloplast-B. Após a escovação, todos apresentaram valores estatisticamente diferentes entre si, na seguinte crescente: Sofreliner, Molloplast-B e Luci Sof. A imersão em Efferdent promoveu diminuição significativa dos valores de dureza para todos os materiais. A imersão em Hipoclorito de Sódio promoveu diminuição significativa dos valores de dureza dos materiais Sofreliner e Molloplast-B
Abstract: The aim of this study was to evaluate the influence of mechanical brushing and denture cleansers on the surface properties of soft lining materials. Three soft liners, Luci Sof (Dentsply), Molloplast-B (Dentax), and Sofreliner (Tokuyama), two denture cleansers Efferdent (Warner-Lamber Co- EUA), and 0,5% alkaline hypochlorite preparation, the Reach Professional toothbrush (Johnson & Johnson) and the dentifrice Sorriso Dentes Brancos (Kolynos do Brasil) were used. Thirty specimens of each soft liner material were prepared by molding the specimen container appliance of the brushing machine, measuring 25mm long, 15mm wide and 3mm thick. Ten specimens of each material were submitted to the mechanical brushing assay, and 20 specimens of each material immersed into the solution of each denture cleanser. The mechanical brushing assay was conducted on the MSEt plus machine, at a rate of 5.0 strokes per second (20.000 cycles). Two denture cleansing approaches were used: 1) specimens immersed in 0.5% alkaline hypochlorite preparation at 37 ± 1 ºC for 20 minutes; 2) specimens immersed in Efferdent at 37 ± 1 ºC for 15 minutes. The specimens were then washed thoroughly with tap water, and immersed into distilled water, for the remainder of the 24 h period, at 37 ± 1 ºC. This procedure was repeated 8 times a day, during 90 days (720 cycles). The specimens were evaluated before and after the cleansing procedures. The surface roughness was evaluated in a profilometer SE 1700 (Kosaka ¿ Laboratory), and the Shore A hardness in a microdurometer GS-709 (Teclock, Japan) with a penetrating load of 10N for 1 second. The observation of superficial morphology from representative specimens of each method of cleanser were observed using a scanning electron microscope JSM 5600 PV model (JEOL-Japan). All numeric data were subjected to Wilcoxon-Mann-Whitney and Kruskal-Wallis tests at the 5% level. The mechanical brushing assay increased significantly the roughness mean values for all materials. The mean values for Luci Sof (Ra=0.74m), Molloplast-B (Ra=1.28m) and Sofreliner (Ra=3.18m) were statistically different after the brushing assay. The Efferdent treatment decreased the roughness mean values of Luci Sof and Sofreliner significantly, but not for Molloplast-B. After the treatment, no differences in the mean values were observed among the materials (Luci Sof Ra=0.32m; Molloplast-B Ra=0.32m; Sofreliner Ra=0.36m). The Hypochlorite treatment decreased the roughness mean values of all materials significantly. After the treatment, neither Luci Sof (Ra=0.29m) and Molloplast-B (Ra=0.27m) nor Molloplast-B and Sofreliner (Ra=0.17m) showed statistically significant differences. The brushig assay decreased the hardness mean values significantly only for Molloplast-B. After the assay, no statistically significant differences were observed for Luci Sof (43.80), Molloplast-B (35.10) and Sofreliner (27.10). The Efferdent treatment decreased the hardness mean values significantly for all materials. After the treatment, mean values of Molloplast-B (25.70) and Sofreliner (25.75) were not statisticaly different, but they differed from that of Luci Sof (36.65). The Hypochlorite treatment decreased the hardness mean values of Molloplast-B and Sofreliner. After the treatment, mean values of Molloplast-B (28.85) and Sofreliner (26.00) were not statisticaly different, but they differed from that of Luci Sof (43.80). The mechanical brushing assay increased the roughness mean values for all materials significantly, from smoothest to roughest in the following order: Luci Sof, Molloplast-B, and Sofreliner. The denture cleansers decreased the roughness mean values of Luci Sof and Molloplast-B, and increased this values for Sofreliner in Efferdent. The mechanical brushing decreased the hardness mean value of Molloplast-B, and after this treatment, all materials showed statistical significantly differences, from smoothest to hardest in the following order: Sofreliner, Molloplast-B, and Luci Sof. The Efferdent treatment decreased the hardness mean values for all materials significantly. The Hypochlorite treatment decreased the hardness mean values for Sofreliner and Molloplast-B significantly
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
7

Gomes, Ana Paula Martins [UNESP]. "Avaliação da biocompatibilidade de dois adesivos dentinários pelo estudo das reações teciduais em conjuntivo de ratos." Universidade Estadual Paulista (UNESP), 1994. http://hdl.handle.net/11449/131905.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:22:29Z (GMT). No. of bitstreams: 0 Previous issue date: 1994-12-16. Added 1 bitstream(s) on 2015-12-10T14:28:36Z : No. of bitstreams: 1 000023949.pdf: 4351925 bytes, checksum: 33bebaef27e694418223c1324c9f2eb1 (MD5)
A biocompatibilidade de dois adesivos dentinários (Scotchbond MultiPurpose- 3M e Optibond Multi-Use - Kerr) foi avaliada por meio de implantes em tecido conjuntivo subcutâneo de ratos. Os implantes foram realizados, utilizando-se tubos de polietileno preenchidos com os respectivos adesivos e inseridos em lojas cirúrgicas preparadas no dorso dos animais, os quais foram sacrificados nos periodos de observação de 14, 30, 60 e 84 dias. Os tecidos circunjacentes aos implantes foram removidos, incluídos em parafina e corados com hematoxilina e eosina para análise em microscopia óptica. Os resultados mostraram moderado a discreto infiltrado inflamatório nos períodos iniciais de observação (14 e 30 dias) e reparação da área nos períodos posteriores (60 e 84 dias), com formação de cápsula fibrosa envolvendo todos os implantes. Os resultados obtidos nos permitiram concluir que: a) os dois adesivos dentinários são biologicamente aceitáveis quando colocados em contato com o tecido conjuntivo subcutâneo de ratos; b) houve reação moderada do tecido conjuntivo subcutâneo de ratos aos dois adesivos dentinários no período de observação de 14 dias, a qual persistiu com o adesivo Optibond MultiUse-light cure- (Kerr) aos 30 dias; c) as reações teciduais provocadas pelos dois adesivos nos períodos de observação de 60 e 84 dias foram semelhantes e biologicamente aceitáveis
The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue
APA, Harvard, Vancouver, ISO, and other styles
8

Gonçalves, Sérgio Eduardo de Paiva [UNESP]. "Adesivos multi-uso-avaliação da resistência adesiva a dentina frente a teste de cisalhamento, estereomicroscopia e microscopia eletrônica de varredura." Universidade Estadual Paulista (UNESP), 1994. http://hdl.handle.net/11449/131859.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:22:16Z (GMT). No. of bitstreams: 0 Previous issue date: 1994-12-15. Added 1 bitstream(s) on 2015-12-10T14:28:20Z : No. of bitstreams: 1 000023950.pdf: 5255881 bytes, checksum: a5b00e9d9a2096ed77f9f420143ca8d6 (MD5)
Adesão tem sido a meta das pesquisas Odontológicas nas últimas décadas. Para determinar se os mais recentes sistemas adesivos denominados como MULTI-USO poderiam ser utilizados associados a diferentes marcas comerciais de resina composta, em dentina, foram realizados testes de resistência ao cisalhamento. Setenta e dois corpos de prova foram confeccionados utilizando-se dentes pré-molares humanos íntegros, embutidos em resina acrílica, expondo-se a dentina por tratamento com lixas d'água de granulações 180, 400 e 600. Os corpos de prova foram divididos em três grupos: Grupo 1 Scotchbond Multi-Purpose (3M), grupo 2 - Optibond Light Cure (Kerr) e grupo 3 - Optibond Dual Cure (Kerr). Todos os grupos foram subdivididos em sub-grupos de 8 dentes, nos quais foram inseridas as resinas compostas: a-Z1 00 (3M do Brasil), bPrisma APH (Dentsply) e c- Herculite XRV(Kerr). Os corpos de prova foram submetidos à ciclagem térmica e após 24 horas de armazenamento em água destilada 370C, aos testes de resistência ao cisalhamento em máquina lnstron 4301 seguidos de análise em estereomicroscópio Technivai-Carl Zeiss de aumento para avaliar o tipo de fratura e, análise em microscopia eletrônica de varredura (M.E.V.). A aplicação do modelo estatístico de análise de variância permitiu a constatação de que o fator Adesivo apresentou um valor significante (p<0,05) independente do fator Resina, tendo o adesivo Optibond Light Cure propiciado a maior resistência média ao cisalhamento (15,446 MPa), seguido do Scotchbond Multi-Purpose (13,340 MPa) e do Optibond Dual Cure (1 0,019 MPa). A interaçâo Adesivo x Resina apresentou um valor estatisticamente significante (p<0,05), onde os melhores resultados foram obtidos entre as resinas Z100 e Herculite XRV com o adesivo Optibond Light Cure, e entre a Resina APH com o adesivo Scotchbond Multi-Purpose. Concluímos que o adesivo Optibond...
Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose
APA, Harvard, Vancouver, ISO, and other styles
9

Mello, Elson Braga de [UNESP]. "Influência do tratamento de superfície na infiltração marginal de reparos em porcelana." Universidade Estadual Paulista (UNESP), 2001. http://hdl.handle.net/11449/110664.

Full text
Abstract:
Made available in DSpace on 2014-11-10T11:09:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-06-19Bitstream added on 2014-11-10T11:57:34Z : No. of bitstreams: 1 000138150.pdf: 3497636 bytes, checksum: ee38fb09ee6e0b606da5fb2a0bca6a51 (MD5)
APA, Harvard, Vancouver, ISO, and other styles
10

Andreatta, Filho Osvaldo Daniel [UNESP]. "Avaliação da resistência adesiva entre um cimento resinoso e ligas para metalo-cerâmica submetidas a dois diferentes condicionamentos de supefície." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/114079.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-12Bitstream added on 2015-01-26T13:30:14Z : No. of bitstreams: 1 000436713.pdf: 7731647 bytes, checksum: 9b7aadb95aa028efeda85c7c4760387c (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O objetivo deste estudo foi avaliar a hipótese de que diferentes condicionamentos de superfície de três ligas para próteses metalo-cerâmica (Ouro - Degudent U – Degussa; Níquel-Cromo - Wiron 99, Bego; Titânio - Rematitan, Dentaurum) não alteram os valores de resistência adesiva com um cimento resinoso. Vinte blocos de cada liga com dimensões de 5x5x5mm foram fundidos e divididos em dois subgrupos de 10 blocos e condicionados com os seguintes tratamentos de superfície: TRAT. 1 (Primer) – jateamento com partículas de óxido de alumínio 110µm (Al2O3) + Alloy Primer (Kuraray, CO) e TRAT. 2 (Cojet)– jateamento com partículas de sílica com o sistema Cojet (3M/ESPE) + Silano ESPE-Sil (3M/ESPE). Os blocos condicionados de cada grupo foram cimentados com Panavia F (Kuraray, CO) a blocos de resina composta ClearfilTM AP-X (Kuraray, CO) sob carga constante de 750g por 10 minutos. Foram determinados, portanto, seis grupos experimentais constituídos por conjuntos formados pela liga, cimento e resina composta. Estes foram cortados em uma máquina de corte obtendo-se por bloco cimentado 4 amostras com dimensões de 10x1x1mm sendo que a superfície adesiva apresentou aproximadamente 1mm2 de área. O teste de microtração foi realizado em máquina de testes universal (EMIC) com célula de carga de 10kgf e velocidade de 1mm/min. Cada grupo foi representado por quarenta amostras, entretanto cada grupo apresentou 10 valores médios de resistência adesiva em MPa (n=10), sendo que cada valor foi proveniente da média obtida a partir dos valores individuais das quatro amostras de cada conjunto de blocos cimentados. Os valores de resistência adesiva e os desvios-padrão (MPa) para os grupos foram : G1: 7,33 ± 1,93d; G2: 13,35 ± 2,18 c G3: 23,56 ± 6,5 b; G4:42,6 ± 5,84 a; G5: 26,17 ± 1,94 b; G6: 44,30 ± 2,3 a. Os dados de resistência adesiva foram analisados estatisticamente pelo teste de ....
The aim of this study is to evaluate the hypothesis that different conditionings of surface of three dental alloys (Gold - Degudent U – Degussa; Nickel-chromium - Wiron 99, Bego; Titanium - Rematitan, Dentaurum) they do not modify the values of bond strength with a resin cement. Twenty blocks of each alloy with dimensions of 5x5x5mm were cast and divided in two subgroups of 10 blocks that were conditioned with the following surface treatments: TRAT. 1 – sandblasting with particles of oxide of aluminum 110μm (Al2O3) + Alloy Primer (Kuraray, CO) and TRAT. 2 - sandblasting with particles of oxide of silica with Cojet-Sand (3M/ESPE) + Silane (ESPE-SIL). The conditioned blocks of each group were luted with Panavia F (Kuraray, CO) to composite resin blocks of ClearfilTM AP-X (Kuraray, CO) under constant load of 750g for 10 minutes. Six experimental groups were constituted by sets formed by the alloy, cement and composite resin. The sets were split up in a mechanical lathe obtaining by block 4 samples with dimensions of 10x1x1mm and the adhesive surface with approximately 1mm2. The microtensile test was accomplished in an universal test machine (EMIC) with cell of load of 10kgf and crosshead speed of 1mm/min. Each group was represented by forty samples, however each group presented 10 means values of bond strength MPa (n=10), obtained from the mean of the individual values of the four samples of each cemented blocks. Means and standard deviation of bond strength (MPa) were: G1: 7.33 ± 1.93d; G2: 13.35 ± 2.18 c G3: 23.56 ± 6.5 b; G4:42.6 ± 5.84 a; G5: 26.17 ± 1.94 b; G6: 44.30 ± 2.3 a. The data of bond strength were analyzed by the analysis of variance test (ANOVA) and Tukey test, p<0.05. The results indicated that surface treatment 2 (Cojet) increased the bond strength between the resin cement and alloys. The smallest values of bond strength were obtained with gold alloy, independent of ....
APA, Harvard, Vancouver, ISO, and other styles
11

Nakaoka, Marcia Mika. "Efeito da termociclagem e do citrato sobre a deformação permanente e resistencia a tração da união de um reembasador resiliente unido a resina acrilica." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289922.

Full text
Abstract:
Orientador: Marcelo Ferraz Mesquita
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T03:47:43Z (GMT). No. of bitstreams: 1 Nakaoka_MarciaMika_M.pdf: 3146053 bytes, checksum: a03bb35599db030272585c8a34b3893e (MD5) Previous issue date: 2005
Resumo: O objetivo deste trabalho foi avaliar e comparar o desempenho de um material reembasador resiliente à base de resina acrílica (Eversoft com ou sem adição de citrato à composição), submetido ou não ao envelhecimento (termociclagem), sobre as propriedades de deformação permanente e resistência à tração da união com resina acrílica (QC-20®). Para a realização dos ensaios foram confeccionadas 80 amostras, metade para cada ensaio, separadas por composição e submetidas ou não à termociclagem, totalizando 8 grupos. Para o ensaio de tração, foram utilizadas matrizes retangulares de 10mm2 de secção transversal e um espaçador de 3mm de espessura para padronizar o espaço para a base resiliente, cujo molde impresso no silicone polimerizado por reação de condensação foi preenchido com resina acrílica e material resiliente. A resina acrílica foi incluída com o espaçador e após a polimerização, o espaçador foi removido, as amostras de resina acrílica retiradas do molde e realizado o acabamento. As amostras de resina acrílica retornaram ao molde, e no lugar do espaçador, os materiais resilientes foram prensados e termopolimerizados de acordo com as instruções dos fabricantes. Para o ensaio de deformação permanente, foram utilizadas matrizes cilíndricas de 12,7mm de diâmetro e 19mm de altura, cujo molde impresso no silicone foi preenchido com material resiliente. Metade das amostras de cada ensaio foi levada ao termociclador MSCT-3 PLUS, onde foram realizados 3.000 ciclos de 1 minuto de imersão em água a 5±1ºC e 1 minuto a 55±1ºC. A outra metade foi armazenada em água numa estufa a 370C durante 24 horas. As amostras foram submetidas ao ensaio de tração no equipamento EMIC-DL500MF com velocidade de 5 mm/minuto. As amostras foram avaliadas visualmente quanto ao tipo de ruptura ocorrida, e amostras representativas de cada tipo foram analisadas através de microscopia eletrônica de varredura em microscópio modelo JSM 5600 PV (JEOL, Japão). As amostras do estudo de deformação permanente foram ensaiadas em um aparelho mecânico recomendado na especificação no18 da American Dental Association (A.D.A.). Todos os dados obtidos foram submetidos à análise de variância em esquema fatorial 2x2 e as médias comparadas pelo Teste de Tukey, em nível de significância de 5%. Em relação aos valores médios de resistência à tração da união dos materiais não submetidos à termociclagem, o Eversoft com citrato ¿ Experimental apresentou menor valor (0,39 MPa), porém sem diferença estatística com o Eversoft sem citrato ¿ Eversoft® (0,44 MPa). Houve aumento dos valores médios de resistência à tração da união quando submetido à termociclagem para o Eversoft® (0,46 MPa) e Experimental (0,55 MPa), sendo estatisticamente significativo apenas para o material Experimental Em relação aos tipos de fratura, para ambos materiais não submetidos à termociclagem, predominaram rupturas coesivas (80%); e quando submetidos à termociclagem, foram observadas rupturas adesivas para o material Experimental (80%) e adesivas e mistas (40% e 50%, respectivamente) para o Eversoft®. Em relação à deformação permanente, os valores médios obtidos para os materiais Eversoft® e Experimental não submetidos à termociclagem (1,06% e 1,82%, respectivamente) diferiram estatisticamente quando submetidos à termociclagem (1,36% e 1,98 %, respectivamente). A termociclagem não afetou a resistência à tração da união para o material Eversoft®, enquanto o Experimental apresentou elevação no valor médio de resistência à tração da união, com diferença estatística significativa. A termociclagem elevou os valores médios de deformação permanente para ambos materiais. Independentemente do tratamento, o material resiliente Experimental apresentou o valor médio mais elevado para deformação permanente
Abstract: The aim of this study was to evaluate and compare the effect of citrate added or not to a composition of acrylic-based soft liner (Eversoft) on its permanent deformation and bond strength with acrylic resin (QC-20®). Eighty samples were used to carry out the two assays containing 40 specimens each: 2 materials (Eversoft® and Eversoft + citrate) and 2 treatments (with and without thermocycling) totaling 8 groups of 10 specimens each. For the tensile test, rectangular specimens with a 10x10mm2 cross sectional area were prepared for each acrylic resin and soft liner. Acrylic resin specimens were prepared by investing brass dies with a 3mm thick spacer in a denture flask. The dies and spacers were invested in silicone rubber. All dies and the spacer were machined to the same dimensions to standardize acrylic resin and soft liner shape. Specimens were made by processing soft liner against acrylic resin blocks according to the manufacturers¿ directions. For the permanent deformation, the specimens were prepared by investing brass dies (12.7 x 19.0 mm) in a denture flask and the model impressed was filled up with a soft liner. Half of the specimens of each assay were thermocycled using the MSCT-3 Plus with cycles of 1 minute in water at 5±1ºC and 1 minute in water at 55±1ºC, totaling 3000 cycles. The other half was stored in water at 370C for 24h. For the tensile test, the specimens were submitted to a bond strength testing machine (EMIC DL-500 MF) at the crosshead speed of 5mm/minute. Samples were visually evaluated as to the types of rupture observed in this study. The Scanning Electron Microscope JSM 5600 PV (JEOL, Japan) was used to analyze the representative samples. Permanent deformation was measured with an instrument described in the American Dental Association (A.D.A.) - specification number18. The data were submitted to a 2-way analysis of variance and the Tukey test (5%). The bond strength test, without thermocycling, revealed a lower mean value (0.39 MPa) for the group Eversoft with citrate - Experimental; however, no statistically significant difference was observed for the group Eversoft without citrate - Eversoft® (0.44 MPa). Thermocycling did not affect the bond strength regarding Eversoft® (0.46 MPa); however, Experimental presented a higher mean value (0,55 MPa) ¿ statistically significant. Both materials, without thermocycling, presented cohesive failures (80%). When submitted to thermocycling, 80% of adhesive failures were observed for Experimental, and 40% of adhesive and 50% of a combined mode of failures for Eversoft®. In relation to the permanent deformation, Eversoft® and Experimental, not submitted to thermocycling, presented mean values (1.06% and 1.82%, respectively) differing statistically from those submitted to thermocycling (1.36% and 1.98%, respectively). Thermocycling did not affect the bond strength regarding Eversoft®; however, Experimental presented a higher mean value. Thermocycling had a deleterious effect on the permanent deformation of both materials. Regardless of treatment, statistically significant difference was observed for Experimental group, showing the highest permanent deformation permanent value
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
12

Monteiro, Wildes da Costa. "Avaliação das alterações dimensionais em modelos de gesso para protese total por meio de medição tridimensional em função de materiais e tecnicas de moldagem." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290120.

Full text
Abstract:
Orientador: Simonides Consani
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T11:55:19Z (GMT). No. of bitstreams: 1 Monteiro_WildesdaCosta_D.pdf: 6985087 bytes, checksum: dab5ef3ae95601eac48a0d542f0cf87f (MD5) Previous issue date: 2005
Resumo: O objetivo deste estudo foi analisar por meio de medições tridimensionais, as alterações dimensionais que ocorrem nos modelos de gesso utilizados na confecção de prótese total, em função de diferentes materiais para moldagem: silicone, alginato e godiva equalizada com alginato. Foram confeccionados 45 modelos de gesso tipo IV, (n=15) construídos a partir de moldes obtidos de um modelo padrão metálico de alumínio, onde foram colocados 7 parafusos com 3,5 mm de diâmetro, para estabelecer pontos referenciais das distâncias a serem mensuradas. Esses pontos referenciais permitiram criar segmentos para o cálculo do volume e da área gerados nas figuras representativas dos modelos de gesso, permitindo avaliar a estabilidade dimensional dos modelos em gesso por meio de medições tridimensionais. No CETEF os modelos de gesso foram submetidos às medições tridimensionais no aparelho Mitutoyo, modelo BLN 710, equipado com cabeça de medição Renishaw PH9 e apalpador TP200 com esfera de 1mm de diâmetro, para as seguintes etapas: 1- transferência das coordenadas tridimensionais para o programa Mechanical Desktop; realização dos desenhos bidimensionais; medição dos seguimentos que compõem cada figura desenhada de cada desenho; realização dos desenhos tridimensionais; cálculo do volume e da área projetada utilizando a malha de elementos finitos e confecção de uma planilha de cálculo para cada material de moldagem; tratamento estatístico dos dados e determinação matemática das variações e das coordenadas x, y e z dos comprimentos de cada um dos segmentos, dos perímetros e das áreas de cada figura dos quarenta e cinco modelos. 2- lançamento dos dados nas planilhas de cálculo; tratamento estatístico dos dados e determinação matemática das variações e das coordenadas x, y e z dos comprimentos de cada um dos segmentos, dos perímetros e das áreas de cada figura. 3- apresentação tridimensional das variações dimensionais encontradas nos modelos; transferência das variações das coordenadas do grupo de modelos de cada material, em relação ao modelo padrão, para o software de desenho 3D ¿ Mechanical Desktop; geração das figuras para visualização das variações e elaboração de relatório técnico. Os resultados foram submetidos à média matemática simples da dispersão ou variação dos dados, que é o grau no qual os dados numéricos da amostra tendem a dispersar-se em torno de um valor médio. Foi utilizado neste trabalho o cálculo do desvio padrão simples. Os moldes feitos com silicone por adição produziram modelos com menor variação dimensional (capacidade de repetitibilidade) quando comparados aos modelos obtidos com moldes de alginato e godiva equalizada com alginato. O alginato produziu modelos com grande fidelidade de cópias em função da matriz metálica
Abstract: The purpose of this study was to analyze, through three-dimensional measurements, the dimensional changes in casts of stone used to make complete dentures, in function of different materials for impression: addition reaction silicone, alginate and impression compound reline with alginate. The casts of stone type IV were made from molds obtained from a metallic standard die of aluminum. In this metallic die were put seven screws with 3,5mm diameter, to establish referential points of the measured distances. The referential points allowed creating segments for the calculation of the area and volume in the representative drawings generated for the stone casts. The procedure allows evaluating the dimensional stability through three-dimensional measurements. In CETEF the stone die were measured with three-dimensional equipment Mitutoyo, model BLN 710, equipped with measurement head Renishaw PH9 and feeler TP200 with sphere of 1mm of diameter, for the stages: 1- Transfer of the three-dimensional coordinates for the program Mechanical Desktop; generation of the two-dimensional drawings; measurement of the segments that compose each drawing; generation of the three-dimensional drawings; projected area determination and volume calculation using the finite elements net; making of a calculation spread sheet for each impression material; statistical treatment of the data and mathematical determination of the variations in the x, y and z coordinates in the lengths of each segments, in the perimeters and in the areas of each drawing of the forty five casts. 2 - Insertion of the data in the calculation spread sheets; statistical treatment of the data and mathematical determination of the variations and in the x, y and z coordinates in the lengths of each one of the segments, in the perimeters and of the areas of each drawing. 3 - Three-dimensional presentation of the dimensional variations found in the models; transfer of the variations of the coordinates of the group of models of each material, for the software of 3D drawing ¿ Mechanical Desktop; generation of the drawings for visualization of the variations and elaboration of technical report. The results were submitted to the simple mathematics medium of the dispersion or variation of the data, that it is the degree, in which the numeric data of the sample tend to disperse around a medium value. It was used in this work the calculation of the simple standard deviation. The molds made with addition reaction silicone produced casts with smaller dimensional variation, when compared to the casts obtained with alginate or impression compound reline with alginate. The silicone presented larger capacity to repeat generated copies of the molds, from the standard die. The cast made with addition reaction silicone presented small variation among themselves when compared to the standard metallic die
Doutorado
Protese Dental
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
13

Silva, Elielson Nóbrega da. "Determinação da tensão de falha de lascamento da porcelana de cobertura em prótese livre de metal utilizando análise de imagem /." São José dos Campos, 2018. http://hdl.handle.net/11449/158299.

Full text
Abstract:
Orientador: Marcos Yutaka Shiino
Coorientador: Alberto Noriyuki Kojima
Banca: Vinícius Anéas Rodrigues
Banca: Vivian Silveira dos Santos Bardini
Resumo: A introdução da zircônia na Odontologia deu-se pela necessidade de melhores propriedades mecânicas dos materiais cerâmicos, pois com a crescente demanda estética, os cerâmicos tornaram-se materiais de largo uso, devido às suas propriedades estéticas e mecânicas. Em busca dessas propriedades, vários estudos analisaram a taxa de sobrevivência de restaurações zircônia-porcelana, relatando como uma das causas de falha a fratura precoce da porcelana de cobertura e o aumento significativo nos relatos clínicos de lascamento da porcelana de recobrimento aplicada sobre "coping" de zircônia. Diante desse problema, o objetivo deste trabalho foi determinar a tensão de falha no lascamento a partir de casos de clínicos e experimentais pertinentes a esse fenômeno em próteses fixas livres de metal .Foram coletados dados de artigos dos últimos 15 anos, por meio das bases de dados Pubmed e Google Schoolar, sendo selecionados para essa revisão os que obtiveram melhor abordagem do assunto, dando ênfase às possíveis causas de falhas nas restaurações cerâmicas dos casos clínicos e os ensaios realizados, visando um melhor entendimento desse fenômeno, via análise quantitativa e qualitativa, para melhor utilização e aproveitamento desse material na Odontologia. Para determinação da tensão de falha, foi empregada a mecânica da fratura linear elástica e determinado o fator de correção da trinca com base nas dimensões da trinca.Com a presente pesquisa, nota-se que amplitude de tensão influencia no proce... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The introduction of zirconia in dentistry was due to the need for better mechanical properties of ceramic materials, because of an increasing aesthetic demand. Ceramics became widely used materials due to their aesthetic and mechanical properties. Aiming at these properties, several studies have analyzed the survival rate of zirconia-porcelain restorations, reporting as one of the causes of failure. Early porcelain fracture coverage and a significant increase in clinical reports of veneering porcelain applied over "coping "of zirconia. In view of this problem, the objective of this work was to determine the failure causes of chipping from clinical and experimental cases associated to this phenomenon in fixed metal free prostheses. Data from articles of the last 15 years were collected through the Pubmed and Google Schoolar databases. Those who obtained the best approach to the subject were selected for this analysis, emphasizing the possible causes of failures in the ceramic restorations of the clinical cases and the tests performed. Aiming for a better understanding of this phenomenon, via quantitative and qualitative analysis, to better use this material in dentistry. To determine the failure causes, linear elastic fracture mechanics were used and the crack correction factor was determined based on the crack dimensions. With the present research, it is noticed that stress amplitude influences in the fracture process, although it has not pointed exactly the cause of the frac... (Complete abstract click electronic access below)
Mestre
APA, Harvard, Vancouver, ISO, and other styles
14

Araujo, Rosehelene Marotta [UNESP]. "Verificação da dureza de gessos em função da compatibilidade com materiais de moldagem à base de borracha." Universidade Estadual Paulista (UNESP), 1986. http://hdl.handle.net/11449/110744.

Full text
Abstract:
Made available in DSpace on 2014-11-10T11:10:01Z (GMT). No. of bitstreams: 0 Previous issue date: 1986Bitstream added on 2014-11-10T11:57:18Z : No. of bitstreams: 1 000023121.pdf: 1889129 bytes, checksum: 7d413d7d31d94f2b417c51acb5fba4e0 (MD5)
O material mais empregado atualmente na construção de modelos é o gesso, que a par de técnica simples reúne condições bastante satisfatórias com relação às propriedades mecânicas, físicas e químicas. Porém, a compatibilidade relativa dos gessos com os materiais de moldagem pode comprometer as qualidades da superfície do modelo. Em nosso trabalho, estudamos a Dureza de dois tipos de gessos: tipo III (gesso pedra) e tipo IV (gesso pedra melhorado), bem como a influência do contacto com três tipos de materiais de moldagem: silicone polimerizada por condensação (Xantopren), polissulfeto (Permlastic) e silicone polimerizada por adição (Provil). Como parâmetro de comparação foi utilizado o gesso reagindo em contacto com uma superfície de vidro...... ( (Resumo completo , clicar acesso eletrônico abaixo)
Currently the most widespread material used in dies is gypsum that together with its simple technique has very satisfactory mechanical, chemical and physical properties. However, its compactibility with the impression materials can compromise the die surface quality. In our work, we studies the hardness of the two gypsum types: Type III (die stone) and type IV (improved die stone), as well as the influence of the contact with three types of impression materials: polymerized silicone for condensation (Xantopren), polysulfide (Permlastic) and polymerized silicone by addition (Provil). As comparison parameter gypsum was used in contact with a glass surface…(Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
15

Araujo, Rosehelene Marotta. "Verificação da dureza de gessos em função da compatibilidade com materiais de moldagem à base de borracha /." Araraquara, 1986. http://hdl.handle.net/11449/110744.

Full text
Abstract:
Orientador: Francisco Pedro Monteiro da Silva Filho
Resumo: O material mais empregado atualmente na construção de modelos é o gesso, que a par de técnica simples reúne condições bastante satisfatórias com relação às propriedades mecânicas, físicas e químicas. Porém, a compatibilidade relativa dos gessos com os materiais de moldagem pode comprometer as qualidades da superfície do modelo. Em nosso trabalho, estudamos a Dureza de dois tipos de gessos: tipo III (gesso pedra) e tipo IV (gesso pedra melhorado), bem como a influência do contacto com três tipos de materiais de moldagem: silicone polimerizada por condensação (Xantopren), polissulfeto (Permlastic) e silicone polimerizada por adição (Provil). Como parâmetro de comparação foi utilizado o gesso reagindo em contacto com uma superfície de vidro...... ( (Resumo completo , clicar acesso eletrônico abaixo)
Abstract: Currently the most widespread material used in dies is gypsum that together with its simple technique has very satisfactory mechanical, chemical and physical properties. However, its compactibility with the impression materials can compromise the die surface quality. In our work, we studies the hardness of the two gypsum types: Type III (die stone) and type IV (improved die stone), as well as the influence of the contact with three types of impression materials: polymerized silicone for condensation (Xantopren), polysulfide (Permlastic) and polymerized silicone by addition (Provil). As comparison parameter gypsum was used in contact with a glass surface…(Complete abstract click electronic access below)
Mestre
APA, Harvard, Vancouver, ISO, and other styles
16

Queiroz, Adriana Cláudia Lapria Faria. "Avaliação de ligas experimentais de titânio para utilização em estruturas metálicas de próteses dentárias." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/58/58131/tde-26032010-095708/.

Full text
Abstract:
A utilização do titânio em odontologia tem aumentado devido suas propriedades mecânicas, biocompatibilidade, resistência à corrosão e baixo peso específico. Entretanto, o uso do titânio em próteses ainda não é rotineiro em virtude de dificuldades no processo de fundição. Uma das maneiras de superar estas dificuldades seria através do desenvolvimento de novas ligas cujo ponto de fusão fosse inferior ao do Ti cp. O objetivo deste estudo foi avaliar as propriedades mecânicas, biológicas e microestrutura de ligas experimentais de titânio para utilização em estruturas metálicas de próteses dentárias, após fundição odontológica, comparando-as ao Ti cp. As ligas experimentais avaliadas foram Ti-5Zr(%p), Ti-5Ta(%p) e Ti-5Ta-5Zr(%p). Os corpos-de-prova foram fundidos por arco voltaico em atmosfera de argônio e injeção por vácuo-pressão. Para avaliação das propriedades mecânicas, corpos-deprova em forma de halteres foram submetidos a ensaios de tração, barras foram submetidas a ensaios de flexão para avaliação do módulo de elasticidade, e hemi-esferas e discos foram submetidos ao teste de desgaste de dois corpos, sendo o perfil das amostras avaliado antes e após o teste para cálculo da perda de altura vertical. Discos foram utilizados para avaliação da microdureza e para caracterização microestrutural. Para avaliação das propriedades biológicas, células SCC9 foram cultivadas em meio de cultura D-MEM/HF12 suplementado sobre discos e poços sem discos foram usados como controle. Após períodos de 1, 4, 7, 10 e 14 dias, foi avaliada a proliferação celular pelo método histoquímico MTT. Aos 7 dias foi avaliada a viabilidade celular após marcação com azul de Trypan e contagem em hemocitômetro. A morfologia celular foi avaliada às 2, 12 e 24 horas através da visualização, em microscópio de fluorescência por epiluminação, do citoesqueleto de actina e dos núcleos, usando, respectivamente, faloidina e DAPI. Os resultados foram submetidos a testes estatísticos e a liga Ti-5Ta apresentou resistência à tração menor que as demais e módulo de elasticidade significativamente menor do que o Ti cp, embora não diferente das demais ligas experimentais. Com relação à resistência à abrasão, as ligas experimentais apresentaram desgaste significativamente menor do que o Ti cp e a liga Ti-5Zr apresentou microdureza significativamente maior do que os demais materiais. Não houve diferença na proliferação e na viabilidade celular entre os materiais. A avaliação da morfologia celular mostrou diferença na proporção de células nos diferentes estágios de desenvolvimento nos períodos de 2 e 12 horas, mas não em 24 horas. O Ti cp apresentou microestrutura do tipo feather-like com fase α, enquanto Ti-5Zr apresentou estrutura do tipo Widmanstätten com fase α e α´. As ligas Ti- 5Ta e Ti-5Ta-5Zr apresentaram as fases α, α´, α´´ e β, com arranjos lamelar e acicular, respectivamente. Os resultados deste estudo sugerem que as ligas estudadas apresentam potencial para aplicação em próteses dentárias, uma vez que suas propriedades biológicas foram semelhantes às do Ti cp, comprovado por proliferação, viabilidade e morfologia celular; e suas propriedades mecânicas, como resistência à abrasão, microdureza e resistência à tração foram satisfatórias, ainda que o módulo de elasticidade possa e deva ser melhorado.
The use of titanium in dentistry have increased due to its mechanical properties, biocompatibility, corrosion resistance and density. However, titanium has not been routinely used because of the difficulties related to casting technique. One of the options to solve these difficulties would be to develop new titanium alloys whose melting point was lower than cp Ti. So, the aim of this study was to evaluate the mechanical and biological properties and microstructure of experimental titanium alloys for prosthesis frameworks, after dental casting, comparing to cp Ti. The experimental alloys evaluated were Ti-5Zr(%w), Ti-5Ta(%w) and Ti-5Ta-5Zr(%w). The samples were cast by voltaic arc in argon atmosphere and vaccum/pressure injection. To evaluate the mechanical properties, dumbbell-shaped samples were submitted to tensile test, slab-shaped were submitted to flexure for modulus of elasticity evaluation, and stylus tips and disks were submitted to two-body wear test, evaluating the profile of the samples before and after the test to calculate vertical height loss. Disks were used for microhardness evaluation and microstructural observation. For the biological properties evaluation, SCC9 cells were cultured in D-MEM/HF12 supplemented on the disks and wells without disks were used as control. After 1, 4, 7, 10 and 14-day period, cell proliferation was measured by MTT method. After 7 days, cell viability was evaluated after Trypan blue marking and counting in a hemacytometer. Cell morphology was evaluated in 2, 12 and 24-hour periods examining, in fluorescence microscope under epifluorescence, actin cytoskeleton and cell nuclei, using, respectively, phalloidin and DAPI. The results were submitted to statistical analysis and Ti-5Ta alloy presented ultimate tensile strength lower than the others and modulus of elasticity statistically lower than cp Ti, but no different to the other experimental alloys. In relation to wear resistance, the experimental alloys presented wear significantly lower than cp Ti and the Ti-5Zr alloy presented microhardness greater than other materials. Cell morphology evaluation showed difference in the proportion of cells in the different stages in 2 and 12-hour periods, but not in 24. The cp Ti presented feather-like structure with α phase while Ti-5Zr presented a Widmanstätten structure with α and α´ phases. The Ti-5Ta and Ti-5Ta-5Zr alloys presented α, α´, α´´ and β phases with lamellar and acicular structures, respectively. The results of this study suggest that the studied alloys could be applied in dental prosthesis, once their biological properties were similar to cp Ti in cell proliferation, viability and morphology; and their mechanical properties, like wear resistance, microhardness and ultimate tensile strength were ideal, although the modulus of elasticity can and should be improved.
APA, Harvard, Vancouver, ISO, and other styles
17

Sanchez, Jose Luiz Lopes. "Estudo "in vitro" da resistencia da união entre resina acrilica e materiais reembasadores resilientes submetidos ou não a termociclagem." [s.n.], 1999. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289909.

Full text
Abstract:
Orientador: Marcelo Ferraz Mesquita
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-25T20:48:57Z (GMT). No. of bitstreams: 1 Sanchez_JoseLuizLopes_M.pdf: 7457590 bytes, checksum: 68530df6a97eededc15c5d1377abc735 (MD5) Previous issue date: 1999
Resumo: Este trabalho teve como objetivo comparar a resistência da união entre bases resilientes (Dentuflex, Ufi-Gel e Eversoft) e resina acrílica (QC-20), submetidas ou não à termociclagem. Foram utilizadas 60 amostras divididas em 6 grupos de variáveis, com 10 repetições cada. Para a confecção das amostras, foram utilizadas matrizes metálicas incluídas em mufla, cujo molde impresso na silicona de condensação e no gesso foi preenchido com resina acrílica. Após polimerizadas, as amostras foram unidas duas a duas em seu eixo longitudinal por uma base resiliente. Em seguida, metade das amostras foi levada ao termociclador MCT2 AMM Instrumental onde foram realizados 3000 ciclos de 1 minuto em água à 5° C '+ ou -'1° C) e 1 minuto em água a 65° C ( '+ ou -'1°C). A outra metade das amostras foi armazenada em água à 37° C durante 24 horas. Após cada período, as amostras foram submetidas a um tracionamento no equipamento EMIC-DL500MF com velocidade de 5mm/minuto. Os dados obtidos foram submetidos à análise estatística pelo Teste de Tukey, ao nível e 5% de probabilidade e as amostras foram analisadas quanto ao tipo de falha ocorrida. O material Dentuflex apresentou os maiores valores de resistência à tração, independentemente do tratamento recebido, apresentando diferença estatística em relação aos demais materiais. O material Eversoft quando termo ciciado apresentou superioridade estatística em relação ao material Ufi-Gel. Para os materiais Dentuflex e Eversoft, a termociclagem aumentou os valores de resistência à tração, apresentando diferença estatística em relação ao controle, entretanto, para o material Ufi-Gel, o comportamento não foi alterado
Abstract: The purpose of this study was to compare the tensile bond strength between soft-liners (Dentuflex, Ufi-Gel and Eversoft) and the acrylic resin (QC-20), submitted or not to the thermal cycling (of 1 minute in water at 5°C and 1 minute in water at 65°C). Twenty samples were made of each soft-liner. Half of each group received thermal cycling, and the other half, did not. For making the samples, metal matrixes were invested in flasks, the molds was packed with acrylic resin and a spacer was used to divided tbe samples in the middle. After the resin curing, the spacer was taken out and the acrylic resins were joint with soft-liner material. Half of the samples were submitted to 3.000 thermal cycles, and the other half, were not. Afterwards, the samples were submitted to the tensile bond strength test in a universal testing machine (EMIC-DL500MF) with a crosshead speed of 5 mm/min. The results, after Tukey test at 5% of probability, showed that the highest values were obtained to the Dentuflex (3:32 MPa), and the lowest values were observed with Ufi-Gel (0.18 MPa), both when submitted to the thermal cycling. According to the results it was observed that: the Dentuflex material presented the highest values of tensile bond strength, independent of the received treatment, presenting statistical differences related to the Eversoft and Ufi-Gel. The Eversoft material when submitted to the thermal cycling presented values statistically higher than the Ufi Gel. For the Dentuflex and Eversoft materials, the thermal cycling increased the tensile bond strength values presenting statistical differences related to the no cycled, and for the Ufi-Gel the behavior was not altered.
Mestrado
Protese Dental
Mestre em Odontologia
APA, Harvard, Vancouver, ISO, and other styles
18

Melo, Filho Antonio Braulino de [UNESP]. "Estudo comparativo in vitro da resistência à remoção de grampos circunferenciais aplicados sobre dentes íntegros e restaurados com resina composta." Universidade Estadual Paulista (UNESP), 1994. http://hdl.handle.net/11449/131989.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:22:56Z (GMT). No. of bitstreams: 0 Previous issue date: 1994-06-30. Added 1 bitstream(s) on 2015-12-10T14:29:10Z : No. of bitstreams: 1 000026434.pdf: 4352939 bytes, checksum: f59dc1edfd8a91ab4f0abc5ee063d699 (MD5)
Foi realizado um estudo experimental in vitro para investigar o comportamento da força necessária para o deslocamento de grampos circunferenciais de P.P.R. em dois grupos de corpos de prova: 1 com regime de trabalho do terminal retentivo sobre esmalte 2 com regime de trabalho do terminal retentivo sobre resina composta Para tal finalidade foi idealizado um dispositivo, construído a partir de uma máquina de costura de marca Elgin que tinha por objetivo simular repetidamente o movimento de introdução e remoção de grampos circunferenciais sobre os corpos de prova. O dispositivo contava ainda com uma plataforma para fixar os corpos de prova e permitir aferições, um contador de ciclos e um dinamometro. Os corpos de prova foram obtidos a partir da inclusão em gesso de dentes naturais extraídos, íntegros, do grupo dos molares, cujas áreas retentivas eram em esmalte natural ou construídas artificialmente, por adição de resina composta. Os grampos foram obtidos a partir de esculturas com resina acrílica e cera e fundidos em liga de cobalto cromo. A resina composta usada foi de última geração, do tipo monomodal, fotopolimerizável e retida no esmalte através de ataque ácido. Os testes foram realizados em meio aquoso, estabelecendo-se para cada corpo de prova cinco mil ciclos. Foram feitas verificações a cada cem ciclos até dois mil e a cada duzentos ciclos até o total de cinco mil. Os resultados mostraram que as variações na quantidade de força necessária para remover os grampos dos corpos de prova durante todo o período dos ensaios foi desprezível, sem significância, tanto para aqueles com áreas retentivas em esmalte como naqueles com áreas retentívas artificialmente feitas com resina composta
An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin
APA, Harvard, Vancouver, ISO, and other styles
19

Di, Hipolito Vinicius. "Efeito de sistemas adesivos sobre a superficie do esmalte dental integro e desgastado." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288193.

Full text
Abstract:
Orientador: Mario Fernando de Goes
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T04:58:32Z (GMT). No. of bitstreams: 1 DiHipolito_Vinicius_M.pdf: 12091121 bytes, checksum: a1fd755e6d549c37830ff5e95c7d0932 (MD5) Previous issue date: 2005
Resumo: O objetivo deste estudo foi avaliar o efeito dos sistemas adesivos autocondicionantes Prompt L-Pop (PLP-ESPE), Adper Prompt (AD-3M/ESPE) e Clearfil SE Bond (SE-Kuraray) no esmalte íntegro (I) e desgastado (D), em comparação com o sistema que utiliza o ácido fosfórico como condicionador Single Bond (SB-3M/ESPE). Um total de 52 terceiros molares humanos hígidos foi utilizado neste experimento. Para a análise do padrão de condicionamento e da interface de união foram utilizados 32 dentes divididos em 4 Grupos. No Grupo1 (n=3) foi aplicado o ácido fosfórico 35%, no Grupo 2 (n=3) o primer ácido do SE, e nos Grupos 3 (n=3) e 4 (n=3) os adesivos PLP e AD, respectivamente. Nos 5 dentes remanescentes de cada Grupo, o procedimento de união foi completado com a aplicação dos respectivos adesivos (Grupos 1 e 2) e fotopolimerização (todos os Grupos). Ainda, sobre cada um destes 5 dentes foi aplicada e fotopolimerizada uma camada do compósito Filtek Z-250 (3M/ESPE). Em 2 destas amostras realizou-se a caracterização morfológica da interface de união, e as 3 restantes foram dissolvidos em HCl 6N obtendo-se reproduções em resina do padrão de condicionamento. Para a avaliação da resistência de união, 20 dentes divididos nos mesmos 4 Grupos (n=5) receberam a aplicação dos adesivos e, sobre suas superfícies, foi construído um bloco de compósito Filtek Z250 de modo incremental. Após 24 horas, procedeu-se o ensaio de microtração e os resultados analisados utilizando o teste de Tukey (µ=0,05). O tipo de fratura foi classificado em: Tipo I- falha adesiva, Tipo II- fratura coesiva no esmalte, Tipo III- fratura coesiva no adesivo, Tipo IV- fratura coesiva no esmalte e no adesivo. O adesivo SE produziu suave desmineralização no esmalte I e D, resultando na formação de camada híbrida extremamente fina. Os adesivos PLP e AD produziram microporosidades em toda a superfície do esmalte, tanto I quanto D, sendo mais agressivo que o SE. Na zona de interface de união houve a difusão da resina na região desmineralizada com formação de uma camada híbrida contínua e uniforme. O ácido fosfórico produziu no esmalte I e D alterações morfológicas mais intensas, com a formação de uma zona híbrida igualmente contínua e uniforme, porém mais espessa. Quanto à resistência de união, os valores [média (MPa) ± desvio-padrão] foram: SB/I-29,74±7,67; SB/D-31,81±6,65; PLP/I-24,27±5,15; PLP/D-25,01±5,16; AD/I-20,49±5,72; AD/D-20,88±5,54; SE/I-17,19±5,03; SE/D-17,92±3,09. O sistema SB produziu valores médios de resistência de união estatisticamente superiores aos demais. Dentre os adesivos autocondicionantes, os melhores resultados foram alcançados pelo PLP, sendo estatisticamente superior ao AD que foi igual ao SE. As condições I e D do esmalte não exerceram influência sobre os resultados de microtração, independente do sistema adesivo empregado. O ácido fosfórico produziu os maiores níveis de alteração morfológica independente da condição do esmalte. Os adesivos autocondicionantes produziram diferentes morfologias após condicionamento. A ação dos adesivos PLP e AD foi mais efetiva quando comparada com o SE, tanto no esmalte I quanto D. Houve predominância do padrão de fratura tipo IV para o sistema SB, enquanto o tipo III prevaleceu nos adesivos autocondicionantes
Abstract: The aim of this study was to evaluate the effect of the self-etching systems Prompt L-Pop (PLP-ESPE), Adper Prompt (AD-3M/ESPE) e Clearfil SE Bond (SE-Kuraray) on ground (G) and unground (U) enamel in comparison to the total-etch system Single Bond (SB-3M/ESPE). Fifty-two non-carious human third molars were used in this study. Thirty-two teeth were separated in 4 Groups of 8 teeth to analyze the etching pattern and the resin-enamel interface. On Group 1 (n=3) a 35% phosphoric acid was applied, on Group 2 (n=3) the SE primer, and on the Groups 3 (n=3) and 4 (n=3) the ¿all in one¿ adhesives systems PLP and AD, respectively. The bonding procedures were performed on the five remainders teeth of each Group with the application of the bonding resins (Groups 1 e 2) and light curing (all the Groups). After that, an increment of the resin composite Filtek Z-250 (3M/ESPE) was applied and light cured on each tooth. Two of these samples were processed for morphologic characterization of the resin-enamel interface, and the three remainder were dissolved in HCl 6N to observe the resin reproduction of the etching pattern. To evaluate the microtensile bond strength, twenty teeth separated in the same four Groups (n=5) received the application of the adhesives and a block the resin composite Filtek Z250 (3M/ESPE) was incrementally built up on their surfaces. After 24 hours, the microtensile bond strength test was performed and the results analyzed by the Tukey¿s test (a=0,05). The fracture pattern was classified in: Type I- interfacial failure, Type II- cohesive failure in enamel, Type III- cohesive failure in bonding resin, Type IV- cohesive failure in enamel and in bonding resin. The self-etching system SE produced shallow demineralization on G and U enamel, resulting in an extremely thin hybrid layer. The ¿all in one¿ adhesive systems PLP and AD were more aggressive than SE, producing microporosities in both G and U enamel. The infiltration of the resin formed a homogenous and uniform hybrid layer. More aggressive morphologic alterations were produced by phosphoric acid in both G and U enamel. This outcomes in a hybrid layer equally continuous and uniform, however thicker. The microtensile bond strength values [Mean (MPa) ± SD] were: SB/U-29.74±7.67; SB/G-31.81±6.65; PLP/U-24.27±5.15; PLP/G-25.01±5.16; AD/U-20.49±5.72; AD/G-20.88±5.54; SE/U-17.19±5.03; SE/G-17.92±3.09. The SB system produced statistically higher bond strength compared to the other adhesive systems. Among the self-etching systems, the best results were obtained with PLP, which was statistically higher than AD that was similar to SE. The G and U conditions didn't show influence on the microtensile bond strength results independent of the adhesive system employed. Despite of the enamel condition, the phosphoric acid produced the highest morphologic alteration. The self-etching systems produced different morphologic features after conditioning. The action of the PLP and AD systems were more effective in comparison to SE for both G and U enamel. There was prevalence of type IV failure pattern for SB, while the type III was more frequent for the self-etching systems
Mestrado
Materiais Dentarios
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
20

Costa, Mariana Machado Teixeira de Moraes [UNESP]. "Avaliação da reação tecidual frente aos cimentos MTA Ângelus® cinza e um MTA fotopolimerizável experimental: análise microscópica em alvéolos dentários de ratos." Universidade Estadual Paulista (UNESP), 2008. http://hdl.handle.net/11449/104239.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-25Bitstream added on 2014-06-13T19:03:55Z : No. of bitstreams: 1 costa_mmtm_dr_araca.pdf: 1110079 bytes, checksum: 91b6d45dfad96a82f57a7802c12b0cb7 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Para contornar algumas dificuldades de manipulação do agregado de trióxido mineral (MTA) convencional, um MTA fotopolimerizável vem sendo desenvolvido. Desta forma, o objetivo do presente estudo foi avaliar a resposta tecidual frente ao uso deste material. Para isso, 57 tubos de polietileno preenchidos com o MTA experimental e o MTA cinza foram implantados em alvéolos de ratos. Como grupo controle, foram implantados tubos vazios. Os animais foram sacrificados após 30, 60 e 90 dias, sendo realizada a análise microscópica dos cortes obtidos e corados com Hematoxilina e Eosina. Foi possível concluir que o MTA fotopolimerizável apresentou uma resposta semelhante ao MTA cinza, caracterizada pela ausência de uma inflamação severa e pela deposição de tecido mineralizado em contato com o material.
The aim of this study was to evaluate the tissue reaction to a Light Cured MTA or MTA Ângelus® gray. It was used 57 animals, which were divided in three groups. In the Control Group, empty tubes were inserted into the rat’s sockets immediately after extraction. In the other groups, the tubes were filled with Light Cured MTA or MTA Ângelus®. After 30, 60 and 90 days after the implantation, the animals were sacrificed and the right hemi-maxilas were removed and processed in laboratory to analyses on light microscopy, with embedding in paraffin, cut with 6μm thickness and stained with HE. It was possible to conclude that Light Cured MTA presented a similar response when compared to MTA Ângelus®, being characterized by a mild inflammatory response and dystrophic calcifications areas. Despite of a favorable healing process obtained with this new experimental MTA, further studies should be conducted to elucidate these material properties and confirm the present results.
APA, Harvard, Vancouver, ISO, and other styles
21

Bin, Claudia Villela [UNESP]. "Citotoxicidade e genotoxicidade de cimentos endodônticos." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/90379.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-10Bitstream added on 2014-06-13T19:31:20Z : No. of bitstreams: 1 bin_cv_me_sjc.pdf: 1076251 bytes, checksum: a167eb57ce7c6168b48f17de4f6795bc (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O MTA é um cimento amplamente utilizado na endodontia devido ao potencial indutor da mineralização, sendo empregado em procedimentos de proteção do complexo dentino/pulpar, retrobturação, perfurações radiculares e de furca e em dentes com rizogênese incompleta. Inicialmente esse material não foi preconizado como cimento obturador de canais radiculares. Entretanto, recentemente foi criado um cimento endodôntico resinoso contendo MTA (MTA Fillapex) com essa indicação, porém não há estudos sobre este novo material. Como o MTA é utilizado sobre os tecidos periodontal, ósseo e pulpar, é importante conhecer seus efeitos citotóxicos e genotóxicos, uma vez que, alguns cimentos endodônticos podem liberar componentes tóxicos, prejudicando o processo de regeneração e reparação dos tecidos no qual entram em contato. Assim, o objetivo deste trabalho foi avaliar a citotoxicidade e genotoxicidade do MTA obturador (Fillapex) comparando-o com o MTA reparador e com o AH Plus. Fibroblastos de hamster Chinês (V79) foram colocados em contato com diferentes diluições de meios de cultura previamente expostos a esses materiais. A citotoxicidade foi avaliada através do ensaio de MTT, em espectrofotômetro, para a verificação da taxa de viabilidade celular. A genotoxicidade foi avaliada pela formação de micronúcleos (MNT), para detecção de mutações cromossômicas. A taxa de sobrevivência celular e o número de micronúcleos antes e após a exposição aos cimentos foram estatisticamente analisados pelo teste de Kruskal-Wallis e teste de Dunn (p<0,05). Os resultados mostraram que o MTA reparador manteve a viabilidade celular acima de 50% em todas as diluições. Porém, tanto o MTA Fillapex quanto o AH Plus foram altamente citotóxicos e capazes de aumentar a formação de micronúcleos em 8 vezes em relação ao grupo controle na diluição 1:4, mostrando que são cimentos cito e genotóxicos
The MTA is a sealer widely used in endodontics and for be considered a material that inducing mineralization, can be used in procedures for protection of dentin/pulp complex, retrofilling root and furcal perforations and in teeth with incomplete root formation. Initially this material was not recommended as root canal sealer. However, recently a resin sealer based on MTA (MTA Fillapex) was created for this indication, but there are no studies on this new material. As the MTA is used on the periodontal tissues, bone and pulp, it is important to know the cytotoxic and genotoxic effects, as some sealers can release toxic components, impairing the process of regeneration and repair of tissues in which they come into contact. Thus, the purpose of this study was to evaluate the cytotoxicity and genotoxicity of MTA obturator (Fillapex) comparing it with the MTA repairer and AH Plus. Chinese hamster fibroblasts (V79) were placed in contact with different dilutions of culture media previously exposed to such materials. Cytotoxicity was evaluated by MTT assay in spectrophotometer to check the viability rate and cell survival. The genotoxicity was evaluated by micronucleus (MNT) to detect chromosomal mutations. The cell survival rate and number of micronuclei before and after exposure to the cement were statistically analyzed by Kruskal-Wallis and Dunn test (p<0.05). The results showed that MTA reparative remained cell viability above 50% in all dilutions. However, both the MTA Fillapex and AH Plus were highly cytotoxic
APA, Harvard, Vancouver, ISO, and other styles
22

Michal, Potran. "Ispitivanje biokompatibilnosti i mehaničkih karakteristika polimera za bazu zubne proteze." Phd thesis, Univerzitet u Novom Sadu, Medicinski fakultet u Novom Sadu, 2015. http://www.cris.uns.ac.rs/record.jsf?recordId=94886&source=NDLTD&language=en.

Full text
Abstract:
U uvodnom delu doktorske disertacije opisuje se kompleksnost problematike korišćenja polimera za bazu zubne proteze, sa osvrtom na njihove opšte osobine, stepen biokompatibilnosti i njihove mehaničke karakteristike. Detaljno je opisana problematika ispitivanja stomatoloških materijala i napravljeno je poređenje i korelacija između in vitro i in vivo načina ispitivanja biokompatibilnosti. Drugi deo obuhvata ispitivanje čvrstoće polimera za bazu zubne proteze i analizu uticaja osobina materijala u odnosu na biološku sredinu u kojoj obavljaju svoju funkciju, i u odnosu na sile kojima su tokom funkcije materijali izloženi. Cilj doktorske disertacije je utvrđivanje stepena biokompatibilnosti i mehaničkih karakteristika toplopolimerizujućih, hladnopolimerizujućih i termoplastičnih akrilata za bazu zubne proteze. Istraživanje je obuhvatilo 3 komercijalna materijala iz grupe akrilata, koji se razlikuju po hemijskom sastavu i načinu polimerizacije. Ispitivanje biokompatibilnosti rađeno je u in vitro i in vivo uslovima. Ispitivanje na ćelijskim kulturama obuhvatalo je dve ćelisjke linije (MRC 5 i L929) sa dva načina kontakta između ćelija i materijala (direktan, indirektan) i dva načina određivanja biološkog ishoda (MTT test, Agar difuzioni test). Istraživanje urađeno in vivo obuhvatalo je test subkutane implantacije, na animalnom modelu pacova, i test iritacije oralne sluzokože na animalnom modelu hrčka. Oba testa rađena su u skladu sa standardom ISO 10993. Cilj in vivo istraživanja bio je ispitivanje reakcije tkiva na implantirani materijal, računajući i završnu integraciju ili dezintegraciju implantiranog materijala. Prednost in vivo istraživanja nalazi seu analizi uticaja materijala na sterilno živo tkivo, uz praćenje imunološke reakcije, kao dopuna prethodnom istraživanju na ćelijskim kulturama. Dopunski deo in vivo ispitivanja biokompatibilnosti određen je prema kliničkoj upotrebi ispitivanih materijala, zbog čega je odabran test oralne iritacije sluzokože. Sluzokoža bukalne kesice sirijskog hrčka sastoji se od pločasto slojvitog epitela sa orožavanjem, što je predstavljao dobar model za ispitivanje polimera za bazu zubne proteze, pošto zubna proteza naleže na sluzokožu nepca i rezidualnog alveolarnog grebena koja takođe orožava. Drugi deo disertacije obuhvatao je ispitivanje mehaničkih karakteristika, pri čemu su urađeni test zatezne čvrstoće, test savojne čvrstoće, test čvrstoće loma i mikrotvrdoće, uz dopunsku analizu pratećih parametara. Rezultati ispitivanja biokompatibilnosti pokazali su da su testovi biokompatibilnosti osetljivi na upražnjeni metodološki postupak. Ispitivanjem na ćelijskim kulturama nisu utvrđene značajne razlike u citotoksičnosti između toplopolimerizujućih, hladnopolimerizujućih i termoplastičnih akrilata. Takođe, rezultati su se razlikovali u odnosu na tip ćelijske kulture i način provere biološkog ishoda, što se slaže sa prethodnim navodima o kompleksnoj problematici njihovog međusobnog poređenja. Ispitivanjem biokompatibilnosti subkutanom implantacijom praćen je inflamatorni odgovor tkiva u vremenskom intervalu od 90 dana. Reakcija organizma na implantirani materijal posmatrana je kroz ćelijske i tkivne parametre, u skladu sa ISO 10993. Dodatno je urađena i analiza hrapavosti implantiranih materijala. Histološkom analizom utvrđena je razlika u inflamatornom odgovoru u odnosu na korišćeni materijal, kao i prema vremenskom intervalu implantacije. Test oralne iritacije sluzokože nije se pokazao kao dovoljno senzitivan za ispitivanje ovih vrsta materijala. Ispitivanjem mehaničkih karakteristika utvrđene su razlike između toplopolimerizujućih, hladnopolimerizujućih i termoplastičnih akrilata. Najveći stepen čvrstoće utvrđen je kod toplopolimerizujućih akrilata dok je najveća konzistentnost rezultata bila u grupi termoplastičnih akrilata. Prezentovano istraživanje predstavlja prvu detaljnu analizu biokompatibilnosti i mehaničkih karaktestistika polimera za bazu zubne proteze.
The introduction describes the complexity of use of denture base materials, with regard to their general characteristics, biocompatibility and mechanical properties. Issues related to the testing of dental materials is described in detail and comparison is made between in vitro and in vivo methods of biocompatibility testing. The second part further covers the determination of strength of previously used materials, in relation to biological environment in which their function is conducted and in relation to the influence of masticatory forces which can contribute to their mechanical failure. The aim of the presented research was to assess the degree of biocompatibility and mechanical properties of cold curing, hot curing and thermoformed denture base materials. The research included three denture base materials, which differed according to their chemical composition and polymerization protocols. The biocompatibility testing was carried out in in vitro and in vivo conditions. The in vitro experiments covered two different cell lines (MRC 5 human lung fibroblasts and L929 mouse fibroblasts) with two types of contact (direct, indirect) and two different types of quantification of biological outcome (MTT assay and Agar overley test). The in vivo assessment of biocompatibility covered the subcutaneous implantation test, on the animal model of Wistar rat, and oral mucosa irritation test, on the animal model of sirian hamster. Both tests were conducted according to the ISO 10993. The aim of the in vivo investigation was to evaluate tissue reactions to the implanted materials, including the final integration or disintegration of the tested materials. The advantage of in vivo investigation included the possibility of monitoring the materials influence on living tissues, with the analysis of imunological response as an addition to the previously conductedresearchon cell cultures. The supplemental part of in vivo investigation was chosen according to the clinical use of the tested materials, which included the oral mucosa irritation test.The mucosa of hamster buccal pouch consists of stratified squamos epithelium, which is considered to be an adequate replacement for the human denture supporting tissues, which also consist of the same type of epithelium. The second part of thesis includes the determination of mechanical properties of denture base materials. It consists of four types of tests: tensile strength test, bending strength test, fracture toughness test and microhardness tests, followed by the analysis of corresponding parameters. The results of the biocompatibility tests showed that the biological outcome of the applied method is highly depended on the methodological procedure. The investigation conducted in vitro, on two different cell lines, did not show significant difference in cytotoxicity between hot curing, cold curing and thermoformed denture base materials. Also, the results were influenced by the type of cell culture and the evaluation method of biological outcome, which agrees with the previous allegations about the complexicity of their mutual comparison. The subcutaneous implantation test covered the inflammatory response in the time period of 90 days. The organism reaction to the implanted material was determined through the cell and tissue parameters of organism response, evaluation of which was conducted according to the ISO 10993. Additionally, the surface roughness of the implanted specimens of materials was also measured. The inflammatory response of the ogranism was influenced by the type of the implanted material and the time interval of implantation. The oral mucosa irritation test has proven not to be sufficiently sensitive for testing of this type of materials. Testing of the mechanical properties od denture base materials, revealed the difference between the cold curing, hot curing and thermofomed denture base materials. The highest strength was observed in hot curing materials, while the highest consistency of the results was observed in thermoformed resins. The presented investigation presents the first detail analysis of the biocompatibility and mechanical properties of the denture base materials, and as such presents a novelty in the field of dental materials characterization.
APA, Harvard, Vancouver, ISO, and other styles
23

Hermann, Caio. "Avaliação comparativa da absorção, solubilidade e dureza em reembasadores resilientes submetidos a termociclagem." [s.n.], 2007. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289911.

Full text
Abstract:
Orientador: Marcelo Ferraz Mesquita
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-09T19:35:25Z (GMT). No. of bitstreams: 1 Hermann_Caio_D.pdf: 888674 bytes, checksum: d3703c6f41944c7eb987d5764bbec2b3 (MD5) Previous issue date: 2007
Resumo: Este trabalho teve como objetivo avaliar comparativamente o efeito do envelhecimento por termociclagem na absorção, solubilidade e dureza em dois materiais reembasadores resilientes considerados de longa duração, um à base de silicone autopolimerizável (Sofreliner MS) e outro à base de resina acrílica termopolimerizável (Super-soft). As amostras foram confeccionadas a partir de matrizes metálicas com formato circular medindo 45 mm de diâmetro X 1 mm de espessura (absorção e solubilidade) e 45 mm de diâmetro X 3 mm espessura (dureza). As matrizes foram incluídas em mufla metálica, obtendo um molde impresso no silicone posteriormente preenchido com os materiais resilientes. Foram confeccionadas 40 amostras, metade para mensuração de absorção de água e solubilidade e outra metade para dureza Shore A, mensurada num durômetro GS ¿ 709 Teclock, Osaka, Japão. Em seguida as amostras foram submetidas ao ensaio de termociclagem numa máquina MSCT ¿ 3 PLUS, regulada em 2.000 ciclos com banhos alternados de 60 segundos a 5±1oC e 55±1oC. Após os ensaios, foram efetuadas novas leituras de dureza Shore A e avaliação quanto à absorção de água e solubilidade. Os valores obtidos foram submetidos ao teste de Shapiro ¿ Wilks para avaliação da normalidade dos dados, seguida da aplicação do teste t de Student. Os resultados de absorção de água e solubilidade apresentaram diferença estatisticamente significante para ambos os materiais, sendo respectivamente 2,69 ± 0,16% e 1,59 ± 0,24% para o material Super ¿ soft e 1,41 ± 0,21% e 0,01 ± 0,1% para o Sofreliner MS (p<0,05). Para o ensaio de dureza Shore A, os valores apresentados antes e após termociclagem foram de 64 e 30 unidades pelos materiais Super ¿ soft e Sofreliner MS, respectivamente, não diferindo estatisticamente considerando os materiais isoladamente (p>0,05). Comparando cada material separadamente antes e após a termociclagem, ambos apresentaram diferença estatisticamente significante entre si (p<0,05). O material Sofreliner MS apresentou menores valores de absorção de água, solubilidade e dureza Shore A. Desse modo, concluiu-se dentro dos limites deste estudo que aparentemente este material deva apresentar melhor comportamento quando utilizado clinicamente
Abstract: The aim of this study was to evaluate the effect of thermocycling on sorption, solubility and Shore A hardness of two resilient definitive lining materials: 1) auto-polymerized silicone base (Sofreliner MS); and 2) heat-polymerized plasticized acrylic resin (Super - soft). To prepare the samples, twenty aluminium matrixes were made (ten for sorption and solubility and ten for Shore A hardness) placed in a flask order to obtain a cast pressed mold, and then filled with resilient lining materials, handled according to the manufacturer¿s directions. The hardness samples were submitted for readings in a Shore A durometer (GS ¿ 709 Teclock, Osaka, Japan). After the readings, the samples were submitted to thermal cycling treatment in a thermal cycler machine (MSCT ¿ 3 PLUS) for 2.000 cycles at temperatures ranging from 5±1oC to 55±1oC and a 60-second dwell time. After thermal cycling new readings of hardness were done, and the values of sorption and solubility calculated by Kasanji & Watkinson equation. The values were submitted to Shapiro ¿ Wilks analysis followed by Student test, with 5% of significance. Sorption and solubility showed statistical significance for both materials (2,69 ± 0,16 and 1,59 ± 0,24 for Super ¿ soft and 1,41 ± 0,21 and 0,01 ± 0,1 for Sofreliner MS) (p<0,05). For Shore A hardness the thermal cycling showed no effect for both materials (64 for Super ¿ soft and 30 for Sofreliner MS) (p>0,05). Sofreliner MS showed the lower values for sorption, solubility and Shore A hardness. Withing the limitations of this in vitro study Sofreliner MS showed best properties
Doutorado
Protese Dental
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
24

Ramos, Carolina Júdica [UNESP]. "Comportamento do esmalte de dentes decíduos após desafio desmineralizante em função de materiais restauradores: estudo ao microscópio de luz polarizada." Universidade Estadual Paulista (UNESP), 2003. http://hdl.handle.net/11449/131934.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:22:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-08-08. Added 1 bitstream(s) on 2015-12-10T14:28:49Z : No. of bitstreams: 1 000209033.pdf: 3006947 bytes, checksum: e0f461b5643caabba97c18e5683c7dda (MD5)
O objetivo deste estudo in vitro foi analisar ao microscópio de luz polarizada o comportamento do esmalte decíduo adjacente a quatro materiais restauradores, após um desafio desmineralizante. Foram realizados preparos cavitários de Classe V nas faces vestibulares de quarenta molares decíduos hígidos, os quais foram aleatoriamente divididos em quatro grupos experimentais (n=10) de acordo com os seguintes materiais: uma resina composta modificada por poliácidos (Dyract AP), uma resina composta híbrida (Z-250), um cimento de ionômero de vidro modificado por resina (Vitremer) e um cimento de ionômero de vidro convencional (Fuji IX GP Fast). Após o polimento das restaurações, os espécimes foram impermeabilizados e submetidos a um desafio desmineralizante representado pela imersão dos espécimes em gelatina acidificada (pH4,5) em temperatura ambiente por 14 dias. Após este período, os espécimes foram incluídos em resina e seccionados longitudinalmente obtendo-se secções de 100µm de espessura, que foram embebidas em água destilada para análise ao microscópio de luz polarizada. Os resultados obtidos revelaram formação de lesões artificiais de cárie em todos os grupos e os valores de profundidade da lesão externa, obtidos por meio de análise histomorfométrica, foram submetidos aos testes estatísticos de Kruskal-Wallis e Dunn (5%) constatando-se que o grupo do cimento de ionômero de vidro exibiu profundidade da lesão externa significantemente menor do que o grupo restaurado com resina composta. Concluiu-se que a desmineralização do esmalte decíduo pode ser influenciada pelo uso de diferentes materiais restauradores
The aim of this in vitro study was to evaluate by polarized light microscopy the development of artificial carious lesions in primary teeth adjacent to different restorative materials. Buccal class V restorations were prepared in 40 deciduous human molars with margins in enamel which were ramdonly divided into four groups (n=10): a poliacid modified resin composite (Dyract AP); a hybrid resin composite (Z-250); a resin-modified glass ionomer cement (Vitremer) and a conventional glass ionomer cement (Fuji IX GP Fast). After the restorative procedures, all teeth surfaces were coated with nail polish, except for the restoration area and 1 mm rim of tooth structure. ln order to induce artificial carious lesions, the specimens were immersed into an acidified gel (pH 4,5) for 14 days at room temperature. After this, the specimens were prepared for polarized light microscopy in an imbibition's media of water. The results showed the development of caries lesions in all groups. The data was analysed by Kruskal-Wallis and Dunn's test (5%) and the specimens restored with glass ionomer cement exhibited- the depth of caries significantly lower than the group restored with composite resin. lt was concluded that the restorative material can influence the demineralization of primary enamel
APA, Harvard, Vancouver, ISO, and other styles
25

Ramos, Carolina Júdica. "Comportamento do esmalte de dentes decíduos após desafio desmineralizante em função de materiais restauradores : estudo ao microscópio de luz polarizada /." São José dos Campos, 2003. http://hdl.handle.net/11449/131934.

Full text
Abstract:
Orientador: Silvio Issáo Myaki
Banca: Maria Naira Pereira Friggi
Banca: Yasmin Rodarte Carvalho
Resumo: O objetivo deste estudo in vitro foi analisar ao microscópio de luz polarizada o comportamento do esmalte decíduo adjacente a quatro materiais restauradores, após um desafio desmineralizante. Foram realizados preparos cavitários de Classe V nas faces vestibulares de quarenta molares decíduos hígidos, os quais foram aleatoriamente divididos em quatro grupos experimentais (n=10) de acordo com os seguintes materiais: uma resina composta modificada por poliácidos (Dyract AP), uma resina composta híbrida (Z-250), um cimento de ionômero de vidro modificado por resina (Vitremer) e um cimento de ionômero de vidro convencional (Fuji IX GP Fast). Após o polimento das restaurações, os espécimes foram impermeabilizados e submetidos a um desafio desmineralizante representado pela imersão dos espécimes em gelatina acidificada (pH4,5) em temperatura ambiente por 14 dias. Após este período, os espécimes foram incluídos em resina e seccionados longitudinalmente obtendo-se secções de 100µm de espessura, que foram embebidas em água destilada para análise ao microscópio de luz polarizada. Os resultados obtidos revelaram formação de lesões artificiais de cárie em todos os grupos e os valores de profundidade da lesão externa, obtidos por meio de análise histomorfométrica, foram submetidos aos testes estatísticos de Kruskal-Wallis e Dunn (5%) constatando-se que o grupo do cimento de ionômero de vidro exibiu profundidade da lesão externa significantemente menor do que o grupo restaurado com resina composta. Concluiu-se que a desmineralização do esmalte decíduo pode ser influenciada pelo uso de diferentes materiais restauradores
Abstract: The aim of this in vitro study was to evaluate by polarized light microscopy the development of artificial carious lesions in primary teeth adjacent to different restorative materials. Buccal class V restorations were prepared in 40 deciduous human molars with margins in enamel which were ramdonly divided into four groups (n=10): a poliacid modified resin composite (Dyract AP); a hybrid resin composite (Z-250); a resin-modified glass ionomer cement (Vitremer) and a conventional glass ionomer cement (Fuji IX GP Fast). After the restorative procedures, all teeth surfaces were coated with nail polish, except for the restoration area and 1 mm rim of tooth structure. ln order to induce artificial carious lesions, the specimens were immersed into an acidified gel (pH 4,5) for 14 days at room temperature. After this, the specimens were prepared for polarized light microscopy in an imbibition's media of water. The results showed the development of caries lesions in all groups. The data was analysed by Kruskal-Wallis and Dunn's test (5%) and the specimens restored with glass ionomer cement exhibited- the depth of caries significantly lower than the group restored with composite resin. lt was concluded that the restorative material can influence the demineralization of primary enamel
Mestre
APA, Harvard, Vancouver, ISO, and other styles
26

Dias, Alexandre Henrique de Moura. "Estudo da influência das características químicas e microestruturais nas propriedades mecânicas de sistemas totalmante cerâmicos /." São José dos Campos, 2002. http://hdl.handle.net/11449/110662.

Full text
Abstract:
Orientador: Marco Antonio Bottino
Banca: Guilherme Elias Pessanha Henriques
Banca: Maria do Carmo de Andrade Nono
Banca: João Candido de carvalho
Banca: Kimpara, Estevão Tomomitsu
RESUMO: O propósito deste estudo foi analisar a influência das características químicas e microestruturais nas propriedades mecânicas dos materiais de infra-estrutura (A -lPSEmpress 2 e B - In Ceram Alumina) e de recobrimento estético (C - Empress cerâmico e D -Vitadur Alfa) de sistemas totalmente cerâmicos. Para determinação dos valores dos parâmetros de propriedades mecânicas foram utilizados os ensaios de flexão em quatro pontos, cisalhamento (com e sem ciclagem) e microdurezasuperficialVickers. As superfícies das cerâmicas foram analisadas por dífração de raios X emicroscopia eletrônica de varredura (MEV). Após os ensaios mecânicos, as superfícies de fratura dos materiais A e B e as interfaces A/C e B/Dforam analisadas quimicamente por EDX e microestruturalmente por MEV. Os resultados foram consistentes com a literatura, onde os materiais são compostos de fases cristalinas e C e D são vítreos. Os valores médios de resistência à fratura por flexão foram coerente com os compostos presentes nas cerâmicas e os desvios padrões foram relacionadosà quantidade de defeitos microestruturais. Os tratamentos estatísticos não paramétrico de Kruskal-Wallis e Weibulldestes dados mostraram uma diferença estatisticamente significante do conjunto A/C em relação aos demais materiais, e do B/Dcom o material B. Não foi observada diferença significativa entre os valores de resistência à fratura obtida nos ensaios de cisalhamento estático e por ciclagem mecânica para um mesmo sistema. No ensaio semciclagern mecânica, verificou-se umamaior resistência adesiva para o sistema A/C, que foi associado à formação de interface química
ABSTRACT: The purpose of this study was 10 analyze the influence of chemical and microestrutural characteristics in the mechanical properties of infrastructurematerials (A -IPS Empress 2 and B - ln Ceram Alumina) and of aesthetic revestiment (C -ceramic Empress and D -VltadurA!fa) of systems all ceramic. Inorder to determine the parameters values for mechanical properties involving 4 points flexural oftest in four points were used, shear bond strength (with andwithout cyclic loading) and Vickers superficialmicrohardness. The ceramic surfaces were analyzed trough X-raydiffraction and scanning electron microscopy (SEM). After the mechanical test, the fracture surfaces of the materials A and B andthe interfaces A/C and B/D were analyzed chemically by EDS andmicrostruturally by SEM. The results complied with the literature,where A and B materials consists of crystalline phases and C andD are vitreous.The average flexure fracture strength values were consistenwiththe present compositions in the ceramic and the standard deviations were related to amount of microstrutural defects. Non parametric statistical treatment refering to Kruskal-Wallis and Weibull and involving these e data evidenced a significant difference in the A/C group compared to the remaining materials, and of B/D group compared to Bmaterial. It was not evidenced significant difference between the fracture strength values originated form the test of static shear bond strength and cyclic loading for one same system. ln the test without cyclic loading, evidenced greater adhesive strengthfor the A/C system andthis was associated to the formation of chemical interface
Doutor
APA, Harvard, Vancouver, ISO, and other styles
27

Naressi, Suely Carvalho Mutti [UNESP]. "Comparação da infiltração marginal de restaurações adesivas empregando instrumento rotativo ou um sistema químico-mecânico na remoção do tecido cariado." Universidade Estadual Paulista (UNESP), 1999. http://hdl.handle.net/11449/114068.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-08-16Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000124606.pdf: 3794271 bytes, checksum: 0b7e3cd809f5ce39ab4e03000f54651a (MD5)
Considerando a validade da proposta de remoção químico-mecânica face às vantagens e indicações que o produto Carisolv apresenta e visando a realização de restaurações duradouras, esta pesquisa teve como objetivo comparar o selamento de restaurações adesivas após a remoção químico-mecânica da cárie com Carisolv (Medi Team) e com o método convencional empregando instrumentos rotatórios. Para tanto, foram utilizados sessenta dentes molares humanos cariados que após a remoção da cárie pelas duas técnicas, receberam restaurações com os materiais adesivos Vitremer (3m), Dyract (Dentsply DeTrey) e TPH Spectrum (Dentsply DeTrey). Foi empregada a metodologia para mícroinfiltração com o corante Rodamina B a 0,2% em todos os corpos de prova, que posteriormente foram seccionados em cortadeira especial e avaliados em estereomicroscópio óptico, atribuindo-se escores conforme o grau de microinfiltração observado. A análise estatística constou dos testes não paramétricos de Kruskaii-Wallis e Mann-Whitney cujos resultados evidenciaram que a infiltração marginal ocorreu na maioria das amostras avaliadas; que a diferença entre os escores apresentados pelos materiais não foi significante com a técnica convencional, porém foi significante quando o Carisolv foi empregado; que o Vitremer apresentou os mais altos valores de microinfiltração em ambas as técnicas e que a remoção do tecido cariado pelo método convencional ou químico-mecânico com Carisolv, não influenciou o desempenho selador dos materiais adesivos empregados
The chemo-mechanical removal of carious tissue using Carisolv (MediTeam) presents several advantages and indications, when lasting adhesive fillings are expected. This research proposes to compare the sealing conditions of adhesive restorations placed on teeth submitted either to the chemo-mechanical method using Carisolv or to the traditional bur method of caries removal. Sixty decayed human molars received, after the removal of the carious tissue, adhesive fillings of Vitremer (3M), Dyract (Dentsply DeTrey) e TPH Spectrum (Dentsply DeTrey). The microleakage was observed using the 0,2% Rodamine B dye method in all the samples. The samples were sectioned and examined under optical stereomicroscopy. The statistical analysis using the Kruskall-Wallis and Mann-Whitney non-parametrics tests showed the existence of marginal leakage in most samples; the differences observed in the materials tested were not significant when the traditional method was used but a statistically significant difference existed when Carisolv was employed; the highest levels of microinfiltration occured with Vitremer and the sealing properties of the various adhesive materials were not influenced by the caries removal method applied
APA, Harvard, Vancouver, ISO, and other styles
28

Torres, Carlos Rocha Gomes [UNESP]. "Avaliação da microinfiltração marginal em restaurações de resina composta, quando o colágeno dentinário é mantido ou eliminado após o condicionamento ácido, alterando-se o período de armazenamento e a termociclagem." Universidade Estadual Paulista (UNESP), 2002. http://hdl.handle.net/11449/114072.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-03-15Bitstream added on 2015-01-26T13:30:16Z : No. of bitstreams: 1 000148105.pdf: 6603398 bytes, checksum: b573466a374fbc1a46aedaa48a08fe0f (MD5)
O objetivo deste estudo foi avaliar o grau de microinfiltração marginal em restaurações de resina composta, diante das variáveis remoção ou não do colágeno dentinário após o condicionamento ácido, e utilização ou não de uma camada de resina composta fluida sobre a dentina desproteinizada, alterando-se os seguintes fatores: a)tempo de armazenagem (0, 6 e 12 meses): b) ciclagem térmica (500, 1.500 e 2.500 ciclos). Para tal, 180 dentes bovinos receberam preparos classe V ao nível da junção amelocementária. Eles foram divididos em três grupos: grupo C - foi aplicado o sistema adesivo Single Bond (3M), segundo as recomendações do fabricante, e a seguir procedida a restauração com a resina composta Z250 (3M); grupo H - após o condicionamento ácido foi aplicada uma solução aquosa de NaOCI a 10% por 1 min, e então aplicado o adesivo Single Bond e a resina composta Z250; grupo HF- semelhante ao grupo H, exceto que após a polimerização do adesivo, uma fina camada de resina composta fluída Natural Flow (DFL) foi aplicada e polimerizada, antes da inserção da resina Z250. Todos os espécimes sofreram 500 ciclos ténnicos (5 ±5°C a 55 ±5°C). Os espécimes em cada grupo foram divididos ao acaso em três subgrupos. No primeiro, a microinfiltração marginal foi avaliada após 24h. No segundo, os espécimes permaneceram imersos em água destilada contendo 0,4% de azida sódica em estufa a 37°C por seis meses, sendo que após este período sofreram mais 1.000 ciclos térmicos. No terceiro, os espécimes permaneceram imersos por 12 meses, e receberam mais 1.000 ciclos térmicos a cada 6 meses, totalizando 2.500 ciclos. Após os respectivos períodos de armazenagem, a microinfiltração marginal foi avaliada pelo método do nitrato de prata seguido pela diafanização. Os espécimes foram analisados em estereomicroscópio e receberam escores de 0 a 4. Os dados...
The aim of this study was to evaluate the marginal microleakage in composite resin restorations. under the variables removal or not of the dentin collagen after the acid conditioning, and utilization or not of a flowable composite resin layer on deproteinized dentin, changing the factors: a) storage time (0, 6 and 12 months); b) thermal cycling (500, 1.500 and 2.500 cycles). For this, 180 bovine teeth received class V cavit preparation at cementun-enamel junction. They were assigned to three groups: group C - was applied the Single Bond adhesive system (3M), according to manufacturer instructions, and restored with Z250 composite resin (3M); group H - after the acid conditioning was applied a 10% NaOCI aqueous solution for 1min, and then applied the adhesive and restored with Z250; group HF - like the group H, except that after the adhesive polymerization. a thin layer of a flowable composite resin Natural Flow (DFL) was applied and polimerized, before the placement of Z250. AIl specimens received 500 thermal cycles (5±5'C to 55±5-'C). The specimens in each group were randomly assigned to three subgroups. In the first, the microleakage was evaluated after 24h. In second, the specimens were stored in distillate water containing 0,4% of sodium azide in stove at 37'C, for 6 months, and after this time received more 1.000 thermal cycles. In the third, the specimens were stored for 12 months, and they received more 1.000 thermal cycles for each 6 months. At the end of each storage time, the microleakage was evaluated by the silver nitrate method, followed by cleaning technique. The specimens were analyzed in stereomicroscope and received scores of 0 to 4. The data were submitted to statistical analysis, using the Kruskal Wallis's and Multiple Comparisons tests. After 6 months of storage, the groups H and HF showed falls in microleakage, while the group C didn't showed significant differences
APA, Harvard, Vancouver, ISO, and other styles
29

Pucci, Cesar Rogério [UNESP]. "Estudo comparativo in vitro da resistência ao cisalhamento de sistemas adesivos em dentina humana: uso de hipoclorito de sódio em sistemas convencionais ou primers acidificados." Universidade Estadual Paulista (UNESP), 2002. http://hdl.handle.net/11449/114076.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-12-11Bitstream added on 2015-01-26T13:30:16Z : No. of bitstreams: 1 000185829.pdf: 6961073 bytes, checksum: 5b5886f8bdc5cdb65a37f1d7e96773e8 (MD5)
O objetivo deste estudo foi avaliar comparativamente, in vitro, a resistência adesiva ao cisalhamento de sistemas adesivos convencionais come sem a remocão do colágeno com hipoclorito de sódio a 10% e adesivos autocondicionantes. Utilizou-se 48 molares humanos extraídos por indicacão cirúrgica ou ortodôntica que, após a limpeza, foram armazenados em freezer a -18°C. Os dentes foram seccionados em urn plano axial mésio-distal separando-os em duas metades, vestibular e lingual. Após o embutimento em resina acrílica, tiveram as superfícies vestibular e lingual desgastadas com lixa numa sequência de granulacão decrescente para padronizar a smear layer e expor a dentina até a espessura de 2 mm. A área de adesão foi delimitada em 3 mm de diâmetro. Os espécimes foram divididos em seis grupos, de acordo com o sistema adesivo e o tratamento dentinário realizado: OBF - adesivo autocondicionante One-Up Bond F (Tokuyama); CSEB - primer autocondicionante Clearfil SE Bond (Kuraray); SB -Single Bond (3M); SBMP - Scotchbond Multi Uso Plus (3M); SBH – após o condicionamento ácido foi utilizado o hipoclorito de sódio a 10% (AD Gel - Kuraray) durante um minuto e em seguida utilizado o Single Bond; SBMPH - após o condicionamento ácido foi utilizado o hipoclorito de sódio a 10% (AD Gel - Kuraray) durante um minuto e, em seguida, utilizado o Scotchbond Multi Uso Plus. A resina composta Z-100 (3M) foi inserida pela técnica incremental, em matriz metálica, sobre a área preparada. 0 ensaio mecânico de cisalhamento foi realizado em uma máquina lnstron Universal à velocidade de 0,5 mm/min. As superfícies fraturadas foram analisadas em estereomicroscópio (Karl Zeiss). Os dados foram submetidos à análise estatística, empregando-se os testes ANOVA e Tukey. Os resultados demonstraram os seguintes valores em MPa: CSEB - 24,362; SB - 20,956; SBH- 17,825; OBF - 17,355; SBMP - 17,218; SBMPH-14,169. Concluimos que...
The aim of this study was to investigate comparatively in vitro the shear bond strength of conventional adhesive systems with and without collagen removal using 10 % sodium hypochlorite and self-etch adhesives. 48 human's molars were extracted for surgery and orthodontic reasons and after cleaning, they were stored in freezers (-18º C). The teeth were sectioned in an axial plan (mesio-distal), separated in two halves, vestibular and lingual. The teeth were mounted in self-cure resin and the labial and lingual surfaces were ground with sequential abrasive sandpaper to standardize the smear layer and expose the dentin with 2 mm of the thickness. The adhesion surface was delimited in 3 mm of diameter, the specimens were separated into six groups in accordance with adhesive system and dentin treatment: OBF - self-etch adhesive One-Up Bond F (Tokuyama); CSEB- self-etch primer Clearfil SE Bond (Kuraray); SB - Single Bond (3M); SBMP - Scotchbond Multi Uso Plus (3M); SBH - after acid etching was used at 10% sodium hypochlorite (AD Gel - Kuraray) during one minute and then Single Bond was used; SBMPH - after the acid etching sodium hypochlorite at 10% was used (AD GelKuraray) during one minute and then Scotchbond Multi Uso Plus was used. The composite resin Z-100 (3M) was inserted by incremental technique with a metallic matrix on a prepared surface. The shear test was realized in an lnstron Universal machine at 0,5 mm/min speed. The fractured surfaces were classified in stereomicroscopic (Karl Zeiss). The data obtained was analyzed by ANOVA and Tukey tests. The data showed the following values (in MPa): CSEB- 24,362; SB- 20,956; SBH - 17,825; OBF - 17,355; SBMP - 17,218; SBMPH- 14,169. We concluded that self-etch adhesive CSEB showed bond strength significantly higher than OBF and SBMP adhesives; the self-etch adhesive with acidificate primer showed bond strength statistically higher than where...
APA, Harvard, Vancouver, ISO, and other styles
30

Antunes, Débora Pinto [UNESP]. "Resistência de união de cimentos resinosos em superfície de cerâmica de Y-TZP após aplicação de filme vitrocerâmico." Universidade Estadual Paulista (UNESP), 2014. http://hdl.handle.net/11449/123259.

Full text
Abstract:
Made available in DSpace on 2015-05-14T16:53:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-04-08Bitstream added on 2015-05-14T16:59:11Z : No. of bitstreams: 1 000822661.pdf: 3005956 bytes, checksum: aa617124450c9641b6ecb66c3cbbdaa9 (MD5)
Comparou-se a resistência de união (RU) dos cimentos resinosos Panavia F (P) (Kuraray) e RelyX U200 (R) (3M ESPE) à cerâmica zircônia através de três diferentes métodos de tratamento da superfície: 1- silicatização triboquímica (ST) (Rocatec Soft - 3M ESPE); 2- glaze (G) (Akyzent glaze spray- VITA); 3- aplicação de vidro bioativo (VBA). Blocos pré-sinterizados do sistema Zirkonzahn (Zirkonzahn) foram seccionados de modo a produzir 90 blocos menores (5 x 4 x 3 mm). Os blocos foram polidos em Politriz com lixas d’água de granulação fina 1000 e 1200 (3M ESPE) e limpos em banho ultrassônico contendo álcool isopropílico a 96% durante 5 min. Após a sinterização dos blocos cerâmicos, foi realizada a aplicação do tratamento de superfície. O Rocatec Soft foi jateado com 2,8 bar, ângulo de incidência perpendicular e distância padrão de 10 mm por 25 s em movimentos circulares. O Akyzent Glaze Spray foi pulverizado por 2 s e em seguida sinterizado em forno Vacumat (Vita) de acordo com recomendações do fabricante. Após a aplicação de 1 gota do vidro bioativo, procedeu-se a secagem e sinterização a 1200 ºC deste material. Em todos os grupos aplicou-se agente de união silano Monobond-S (Ivoclar Vivadent). Nos grupos 3, 4, 5 e 6 a superfície foi primeiramente condicionada com ácido hidrofluorídrico (HF) a 5% durante 2 min, lavada e depois silanizada. A cimentação foi realizada com um dispositivo (Ultradent), produzindo cilindros de cimento resinoso com 2 x 1mm.! Após 24 h os espécimes foram envelhecidos em termocicladora com 5.000 ciclos com banhos de temperatura entre 5 e 55 ºC e submetidos ao ensaio de cisalhamento na Shear Bond Tester (Bisco). O VBA foi analisado qualitativamente por meio de análise térmica diferencial (DTA), através de difração de raios-x (DRX)(Panalytical) e espectroscopia de energia dispersiva de raio-x (EDS) (Oxford Instruments)...
The bond strength of resin cements Panavia F (P) (Kuraray) and RelyX U200 (R) (3M ESPE) to zirconia using three different surface treatments: 1 - triboquemical silicatization (ST); 2 - glaze (G) 3 - bioactive glass (VBA) was compared. Blocks of Zirkonzahn system were cut producing 90 smaller blocks (5 x 4 x 3 mm). The blocks were polished with water finegrained 1000 and 1200 sandpaper in Politriz and cleaned with 96% isopropyl alcohol for 5 min. The Rocatec Soft was etched with 2.8 bar, in a perpendicular way and a distance of 10 mm for 25 s in a circular motion. The Akyzent Glaze Spray was sprayed by 2s and then sintered in oven Vacumat (Vita) according to manufacturer's recommendations. After application of 1 drop of bioactive glass, the material was dried and sintered at 1200 °C. In all groups was applied silane coupling agent Monobond- S (Ivoclar Vivadent). In groups 3, 4, 5 and 6 the surface was first etched with 5% hydrofluoric acid (HF) and then silanized. The cementing was carried out with a device (Ultradent), producing cured cement cylinders of 2 x 1mm. After 24 h the specimens were aged in thermocycler with 5,000 cycles at a temperature of 5 and 55 ºC and subjected to microshear test on Shear Bond Tester (Bisco). VBA was analyzed by means of DTA, XRD and EDS. Optical profilometry (PO) was performed to obtain roughness. After fracture the samples were analyzed through SEM. It was found that XRD revealed the formation of a glass ceramic film. DTA shows that the temperature of 1200 °C is the most suitable for sintering. DRX showed the formation of a glass ceramic film. According to ANOVA, the interaction effect was significant (p = 0.003 < 0.05). The test for multiple comparison of means, Tukey (5%) showed that the TBS (MPa) for VBA were significantly higher than the other groups (with 26.94 ± 3.50 to P and 28.36 ± 3.32 to R), regardless cement kind used. The lowest result...
APA, Harvard, Vancouver, ISO, and other styles
31

Dias, Alexandre Henrique de Moura. "Estudo comparativo da textura superficial entre os materiais estéticos indiretos /." São José dos Campos, 2000. http://hdl.handle.net/11449/110741.

Full text
Abstract:
Orientador: Estevão Tomomitsu Kimpara
Banca: Mauro Antonio de Arruda Notelo
Banca: Marco Antônio Bottino
Resumo: O propósito deste estudo foi avaliar a rugosidade superficial entre materiais de revestimento estético indiretos (Vita VMK95, Solidex, Artglass, Targis). Para tanto, confeccionaram-se 10 corpos-de-prova nas dimensões de 6mm de comprimento por 6mm de diâmetro de cada material. Uma das superfícies planas recebeu acabamento e polimento, conforme recomendações do fabricante. As amostras concluídas foram submetidas a mensuração, através do rugosímetro Hommel Tester T500. Os valores médios de rugosidade máxima entre os materiais em questão, foram 5,731Jm, 5,151Jm, 6,83 1.1m e 3, 721Jm, respectivamente. A seguir foram submetidos a análise de variância (ANOVA), ao nível de 5%, sendo detectado significância. Concluiu-se que o material Sofidex não apresentou diferença estatisticamente significante entre os grupos, enquanto o Targis apresenta significância estatística em relação ao Artglass e a cerâmica Vita vmk95
Abstract: The purpose of this study was to evaluate surface rugosity among indirect esthetic materials (Vita VMK 95, Solidex, Artglass, Targis). Ten samples of each material in the cilindric shape with dimension 6 x 6 mm were manufactured. The surface were submitted to finishing and polishing, according to manufacturer's recommendations. The samples were submitted to measuremenst, using the Hommel Tester T500 device. The average values of maxim surface rugosity among the materiais ín question, were 5, 73pm; 5, 15pm; 6, 83 j.Jm e 3, 72 j.Jm, respectively. Sample were also subjectted to variance analysis- ANOVA (5%), had detected significance. Concluded that the material Solidex did not present significant statistical differences among groups, while Targis presented significant statistical differences in relation to the Artglass and the ceramic Vita vmk95
Mestre
APA, Harvard, Vancouver, ISO, and other styles
32

Salazar, Marocho Susana María. "Efeito da fadiga cíclica na resistência, crescimento subcrítico de trincas e tempo de vida de cerâmicas a base de alumina infiltradas por vidro /." São José dos Campos, 2008. http://hdl.handle.net/11449/97417.

Full text
Abstract:
Orientador: Alvaro Della Bona
Banca: Marco Antonio Bottino
Banca: Mário Alexandre Coelho Sinhoreti
Resumo: O objetivo foi avaliar (1) a influência da microestrutura e composição de cerâmicas a base de alumina e infiltrada por vidro (IA- In-Ceram Alumina, Vita) e com reforço de zircônia (IZ- In-Ceram Zircônia, Vita) no comportamento mecânico quanto à resistência a flexão e fadiga; e (2) o efeito das cargas cíclicas na resistência (σ), crescimento subcrítico de trincas (CST) e tempo de vida (TV) desses materiais cerâmicos. Noventa corpos-de-prova (CP) (1.2 x 4 x 20 mm3) de cada material foram fabricados de acordo com ISO 6872 e instruções do fabricante. Os CP de IA e IZ foram divididos em 6 grupos (n=15), submetidos a: 1) flexão em três pontos em saliva artificial a 37°C (IA3P e IZ3P); e 2) fadiga cíclica em ambiente seco e úmido (IAFS, IAFU, IZFS, IZFU). A resistência inicial (σc) e o número de ciclos nos quais cada CP fraturou foram obtidos a partir do ensaio de flexão (3P) e da fadiga cíclica, respectivamente; e avaliados pela análise estatística de Weibull. O CST foi calculado a partir da velocidade da trinca em função da intensidade máxima de estresse. Para estimar o TV foi utilizado o diagrama de Wöhler (DW). Os valores de σc (MPa) da IA variaram de 340 a 560, e do IZ de 410 a 660. O módulo de Weibull (m) foi 8 para ambas IA e IZ, e a resistência característica (σ0) foi 550 MPa para IZ e 466 MPa para IA. O CST no IZ foi maior na presença de umidade. Baseados na σc e nos dados de fadiga, calculados com uma tensão máxima de 150 MPa, foi estimado em média, um TV de: IZFS= 1.57 x 108; IZFU= 1.70 x 107; IAFS= 1.75 x 106; e IAFU= 8.70 x 105 ciclos. Os CP de IZ apresentaram maiores valores de σc devido a presença de zircônia na sua composição e microestrutura. A partir do DW estimou-se que os materiais IA e IZ, têm uma probabilidade de falha de apenas 5% após 20 anos (10220000 ciclos), se a máxima tensão aplicada em meio úmido não exceder a 316MPa para IZ, e 264MPa para IA
Abstract: The objective of this study was to evaluate (1) the influence of the microstructure and chemical composition on the flexural strength and fatigue of glass-infiltrated alumina-based (IA- In-Ceram Alumina) and zirconia-reinforced (IZ- In-Ceram Zirconia) ceramics; and (2) the effect of the cyclic loading on the strength (σ), subcritical crack growth (SCG) and lifetime (Lt) of these framework ceramics. Ninety specimens (sp)(1.2 x 4 x 20 mm3) were fabricated according to the ISO 6872 standard and manufacturer instructions. IA and IZ sp were divided into 6 groups (n=15) and submitted to: 1) 3-point bending test in artificial saliva at 37ºC (IA3P e IZ3P); 2) cyclic fatigue test under dry and wet conditions (IAFD, IAFW, IZFD, IZFW). The initial strength (σ) and the number of cycles until fracture were obtained from the 3-point bending and cyclic fatigue test, respectively; and evaluated using the Weibull distribution. The SCG was obtained from the velocity of crack propagation (v) with the stress intensity factor. The Lt was described using the Wöhler diagram (WD). The σ values (MPa) ranged from 340 to 560 and from 410 to 660 for IA and IZ, respectively. The Weibull moduli (m= 8) was found similar for both ceramics, and the characteristic mechanical strength (σ0) of IA and IZ was 550 MPa and 466 MPa, respectively. Based on the σ and the calculated fatigue data, using a maximum stress of 150 MPa, an average Lt was estimated as follows: IZFD=, 1.57 x 108; IZFW= 1.70 x 107; IAFD= 1.75 x 106; and IAFW= 8.70 x 105 cycles.. SCG was greater for IZ sp when they were tested in water; the presence of zirconia in the IZ resulted in greater mean σ and σ0 values for IZ than for IA. The WD estimated a probability of failure of only 5% after 20 years (10220000 cycles) for IA and IZ if the maximum applied stress in wet conditions does not exceed to 316 MPa and 264 MPa, respectively
Mestre
APA, Harvard, Vancouver, ISO, and other styles
33

Pereira, Sarina Maciel Braga [UNESP]. "Colonização bacteriana na região marginal de restaurações cerâmicas: efeito do método de remoção do cimento e do polimento." Universidade Estadual Paulista (UNESP), 2015. http://hdl.handle.net/11449/139375.

Full text
Abstract:
Made available in DSpace on 2016-06-07T17:12:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-13. Added 1 bitstream(s) on 2016-06-07T17:16:59Z : No. of bitstreams: 1 000865267.pdf: 860727 bytes, checksum: 462d816a3edd9a695666266dd28a3c7f (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O presente estudo teve como objetivo avaliar o efeito de diferentes métodos de remoção do excesso de cimento e do polimento na formação de biofilme e micromorfologia na região de margem dente/restauração. A partir de dentes bovinos, foram obtidos 96 blocos de dentina (4 mm x 8 mm x 2 mm) que foram moldados e reproduzidos em gesso tipo IV, sobre os quais foram produzidos 96 blocos prensados de cerâmica (Vita PM9, Vita Zahnfabrik; 4 mm x 8 mm x 2 mm) pela técnica de cera perdida. Os blocos de dentina e seus respectivos blocos cerâmicos foram cimentados com um cimento resinoso auto-adesivo (RelyX U200, 3M ESPE) e o excesso de cimento foi removido utilizando diferentes técnicas: MBr: microbrush e fotoativação, MBr-Pol: microbrush, fotoativação e polimento, Pi: pincel e fotoativação, Pi-Pol: pincel, fotoativação e polimento, Foto- Expl: 5 s de fotoativação inicial, explorador e fotoativação final, Foto-Expl- Pol: 5 s de fotoativação inicial, explorador, fotoativação final e polimento, Foto-Bi: 5 s de fotoativação inicial, bisturi e fotoativação final, Foto-Bi-Pol: 5s de fotoativação inicial, bisturi, fotoativação final e polimento. Após 24 h, a rugosidade da região de margem das amostras foi analisada utilizando um rugosímetro (Mitutoyo SJ-400 Tóquio, Japão; três medições em cada amostra). Análise micromorfológica da região foi obtida por microscópio estereoscópico e MEV. Em seguida, as amostras foram contaminadas em caldo de sacarose com suspensão padronizada com Streptococcus mutans, Staphylococcus aureus e Candida albicans e incubados por um período de 48 h. As amostras foram analisadas quantitativamente para aderência bacteriana na região da margem por microscopia de varredura confocal a laser e contagem das unidades formadoras de colônias (UFC/mL), e analisadas qualitativamente usando MEV. Os dados de rugosidade superficial (Ra) foram submetidos à análise de variância (2- way), teste de Tukey..
Abstract This study evaluated the effects of excess cement removal techniques, with or without posterior polishing, on the biofilm formation and micromorphology in the marginal region of the tooth/restoration. From bovine teeth, 96 dentin blocks (4 x 8 x 2 mm) were produced, molded and reproduced in type IV gypsum, on which 96 pressed ceramic blocks (Vita PM9 4 mm x 8 mm x 2 mm, Vita Zahnfabrik) were produces via lost wax technique. The dentin blocks and their respective ceramic blocks were cemented with a self-adhesive resin-cement (RelyX U200, 3M ESPE) and cement excess was removed using different techniques, followed by polishing with silicone tips or, in some cases, not polished at all: MBr: microbrush and photoactivation, MBr-Pol: MBr + polishing, Pi: brush and photoactivation, Pi-Pol: PI + polishing, Photo-Expl: 5 s initial photoactivation, explorer and final curing, Photo-Expl-Pol: Photo-Expl + polishing, Photo-Bi: 5 s initial photoactivation, scalpel and final curing, Photo-Bi-Pol: Photo-Bi + polishing. After 24 hours, the samples marginal region roughness was analyzed using a profilometer (Mitutoyo SJ-400 Tokyo, Japan; three measurements on each sample). Micromorphological analyses of the region were performed by stereoscopic microscope and SEM. Then the samples were contaminated with sucrose broth standardized suspension with Streptococcus mutans, Staphylococcus aureus and Candida albicans and incubated for a period of 48 hours. The samples were quantitatively analyzed for bacterial adherence in the marginal region by confocal laser scanning microscopy and counting of colony forming units (CFU/ml), and qualitatively analyzed using SEM. Roughness data (Ra) were submitted to 2-way ANOVA, Tukey test (5%) and Student's-t tests. CFU, Biomass and bio thickness data were analyzed by Kruskal Wallis', Mann-Whitney's e Dunn's tests. The removing technique statistically influenced the roughness (Ra; p ˂ 0.05), when comparing polished and unpolished...
APA, Harvard, Vancouver, ISO, and other styles
34

Pereira, Sarina Maciel Braga. "Colonização bacteriana na região marginal de restaurações cerâmicas: efeito do método de remoção do cimento e do polimento /." São José dos Campos, 2015. http://hdl.handle.net/11449/139375.

Full text
Abstract:
Orientador: Luiz Felipe Valandro
Banca: Renata Marques de Melo Marinho
Banca: Antonio Olavo Cardoso Jorge
Banca: Marina Amaral
Banca: Rodrigo Othavio de Assuncão e Souza
Resumo: O presente estudo teve como objetivo avaliar o efeito de diferentes métodos de remoção do excesso de cimento e do polimento na formação de biofilme e micromorfologia na região de margem dente/restauração. A partir de dentes bovinos, foram obtidos 96 blocos de dentina (4 mm x 8 mm x 2 mm) que foram moldados e reproduzidos em gesso tipo IV, sobre os quais foram produzidos 96 blocos prensados de cerâmica (Vita PM9, Vita Zahnfabrik; 4 mm x 8 mm x 2 mm) pela técnica de cera perdida. Os blocos de dentina e seus respectivos blocos cerâmicos foram cimentados com um cimento resinoso auto-adesivo (RelyX U200, 3M ESPE) e o excesso de cimento foi removido utilizando diferentes técnicas: MBr: microbrush e fotoativação, MBr-Pol: microbrush, fotoativação e polimento, Pi: pincel e fotoativação, Pi-Pol: pincel, fotoativação e polimento, Foto- Expl: 5 s de fotoativação inicial, explorador e fotoativação final, Foto-Expl- Pol: 5 s de fotoativação inicial, explorador, fotoativação final e polimento, Foto-Bi: 5 s de fotoativação inicial, bisturi e fotoativação final, Foto-Bi-Pol: 5s de fotoativação inicial, bisturi, fotoativação final e polimento. Após 24 h, a rugosidade da região de margem das amostras foi analisada utilizando um rugosímetro (Mitutoyo SJ-400 Tóquio, Japão; três medições em cada amostra). Análise micromorfológica da região foi obtida por microscópio estereoscópico e MEV. Em seguida, as amostras foram contaminadas em caldo de sacarose com suspensão padronizada com Streptococcus mutans, Staphylococcus aureus e Candida albicans e incubados por um período de 48 h. As amostras foram analisadas quantitativamente para aderência bacteriana na região da margem por microscopia de varredura confocal a laser e contagem das unidades formadoras de colônias (UFC/mL), e analisadas qualitativamente usando MEV. Os dados de rugosidade superficial (Ra) foram submetidos à análise de variância (2- way), teste de Tukey..
Abstract This study evaluated the effects of excess cement removal techniques, with or without posterior polishing, on the biofilm formation and micromorphology in the marginal region of the tooth/restoration. From bovine teeth, 96 dentin blocks (4 x 8 x 2 mm) were produced, molded and reproduced in type IV gypsum, on which 96 pressed ceramic blocks (Vita PM9 4 mm x 8 mm x 2 mm, Vita Zahnfabrik) were produces via lost wax technique. The dentin blocks and their respective ceramic blocks were cemented with a self-adhesive resin-cement (RelyX U200, 3M ESPE) and cement excess was removed using different techniques, followed by polishing with silicone tips or, in some cases, not polished at all: MBr: microbrush and photoactivation, MBr-Pol: MBr + polishing, Pi: brush and photoactivation, Pi-Pol: PI + polishing, Photo-Expl: 5 s initial photoactivation, explorer and final curing, Photo-Expl-Pol: Photo-Expl + polishing, Photo-Bi: 5 s initial photoactivation, scalpel and final curing, Photo-Bi-Pol: Photo-Bi + polishing. After 24 hours, the samples marginal region roughness was analyzed using a profilometer (Mitutoyo SJ-400 Tokyo, Japan; three measurements on each sample). Micromorphological analyses of the region were performed by stereoscopic microscope and SEM. Then the samples were contaminated with sucrose broth standardized suspension with Streptococcus mutans, Staphylococcus aureus and Candida albicans and incubated for a period of 48 hours. The samples were quantitatively analyzed for bacterial adherence in the marginal region by confocal laser scanning microscopy and counting of colony forming units (CFU/ml), and qualitatively analyzed using SEM. Roughness data (Ra) were submitted to 2-way ANOVA, Tukey test (5%) and Student's-t tests. CFU, Biomass and bio thickness data were analyzed by Kruskal Wallis', Mann-Whitney's e Dunn's tests. The removing technique statistically influenced the roughness (Ra; p ˂ 0.05), when comparing polished and unpolished...
Doutor
APA, Harvard, Vancouver, ISO, and other styles
35

Ramos, Nathália de Carvalho. "Caracterização microestrutural e crescimento subcrítico de trincas em cerâmicas odontológicas /." São José dos Campos, 2014. http://hdl.handle.net/11449/127635.

Full text
Abstract:
Orientador: Renata Marques de Melo Marinho
Co-orientador: Paulo Francisco César
Banca: Marco Antônio Bottino
Banca: Guilherme de Siqueira Ferreira Anzaloni Saavedra
Banca: João Paulo Barros Machado
Resumo: O objetivo do trabalho foi caracterizar a microestrutura de quatro cerâmicas odontológicas CAD/CAM e avaliar a susceptibilidade à corrosão sob tensão. MEV-FEG e análise química com EDS foram realizados para a caracterização microestrutural. Para avaliar o padrão de cristalização das cerâmicas foi usado DRX e FT-IR. Módulo elástico, coeficiente de Poisson, densidade e tenacidade à fratura também foram mensurados. Os espécimes foram submetidos ao ensaio de flexão biaxial sob cinco taxas de tensão constante (0,006; 0,06; 0,6; 6 e 60 MPa/s), a fim de se determinar os parâmetros de crescimento subcrítico da trinca (CST) (n = coeficiente se susceptibilidade ao CST). Vinte e cinco espécimes foram ensaiados na maior taxa de tensão em óleo mineral para determinar a resistência inerte e realizar a análise de Weibull. Duzentos e quarenta discos cerâmicos (12 mm de diâmetro e 1,2 mm de espessura) foram feitos de quatro cerâmicas: cerâmica infiltrada por polímero - CIP (Vita Enamic, Vita Zahnfabrik, Bad Sackingen, Alemanha), cerâmica feldspática - FEL (Vita Mark II, Vita Zahnfabrik), cerâmica de dissilicato de lítio - DSL (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) e cerâmica de silicato de lítio reforçada por zircônia - SLZ (Vita Suprinity, Vita Zahnfabrik). A CIP foi caracterizada como geopolímero reforçado com polímeros, apresentando uma fase orgânica e outra inorgânica, obteve n = 29,1 ± 7,7 e módulo de Weibull (m) de 8,96. A FEL apresentou n = 36,6 ± 6,8 e m = 8,02. O DSL mostrou uma estrutura com grãos afilados de dissilicato envoltos em uma matriz vítrea e obteve o menor valor de n (8,4 ± 0,8) e m = 6,19. O SLZ mostrou grãos semelhantes a bastonetes, n = 11,2 ± 1,4 e m = 9,98. FEL apresentou menor susceptibilidade à corrosão sob tensão, DSL e SLZ apresentaram maior susceptibilidade. A CIP apresentou menor módulo elástico e nenhum cristal em sua composição. SLZ mostrou a presença...
Abstract: The aim of this study was to characterize the microstructure of four dental CAD-CAM ceramics and evaluate their susceptibility to stress corrosion. SEM and EDS were performed for microstructural characterization. For evaluation of the pattern of crystallization of the ceramics and the molecular composition, XRD and FTIR, respectively, were used. Elastic modulus, Poisson's ratio, density and fracture toughness were also measured. The specimens were subjected to biaxial flexure under 5 stress rates (0.006, 0.06, 0.6, 6 and 60 MPa/s) to determine the subcritical crack growth parameters (n and D). Twenty five specimens were further tested in mineral oil for determination of Weibull parameters. Two hundred forty ceramic discs (12 mm diameter and 1.2 mm thick) were made of four ceramics: feldspathic ceramic - FEL (Vita Mark II, Vita Zahnfabrik), ceramic-infiltrated polymer- PIC (Vita Enamic, Vita Zahnfabrik), lithium disilicate - LD (IPS e.max CAD, Ivoclar Vivadent) and zirconia-reinforced lithium silicate- LS (Vita Suprinity, Vita Zahnfabrik). PIC was characterized as a geopolymer reinforced by polymers. It presented organic and inorganic phases (n = 29.1 ± 7.7) and Weibull modulus (m) of 8.96. The FEL showed n = 36.6 ± 6.8 and m = 8.02. The LD showed a structure with needle-like disilicate grains in a glassy matrix and had the lowest value of n (8.4 ± 0.8) and m= 6.19. The ZLS showed similar rod-like grains, n = 11.2 ± 1.4 and m= 9.98. The FEL showed the lowest susceptibility to SCG corrosion, where as LD and ZLS presented the highest. The PIC presented the lowest elastic modulus and no crystals in its composition. ZLS presented tetragonal zirconia in its composition and showed the highest Weibull modulus among the materials studied
Mestre
APA, Harvard, Vancouver, ISO, and other styles
36

Andreatta, Filho Osvaldo Daniel. "Avaliação da resistência adesiva entre um cimento resinoso e ligas para metalo-cerâmica submetidas a dois diferentes condicionamentos de supefície /." São José dos Campos, 2005. http://hdl.handle.net/11449/114079.

Full text
Abstract:
Orientador: Renato Sussumu Nishioka
Banca: Matsuyoshi mori
Banca: Lourenço Correr Sobrinho
Banca: Carlos Augusto Pavanelli
Banca: Jose Roberto Rodrigues
Resumo: O objetivo deste estudo foi avaliar a hipótese de que diferentes condicionamentos de superfície de três ligas para próteses metalo-cerâmica (Ouro - Degudent U - Degussa; Níquel-Cromo - Wiron 99, Bego; Titânio - Rematitan, Dentaurum) não alteram os valores de resistência adesiva com um cimento resinoso. Vinte blocos de cada liga com dimensões de 5x5x5mm foram fundidos e divididos em dois subgrupos de 10 blocos e condicionados com os seguintes tratamentos de superfície: TRAT. 1 (Primer) - jateamento com partículas de óxido de alumínio 110µm (Al2O3) + Alloy Primer (Kuraray, CO) e TRAT. 2 (Cojet)- jateamento com partículas de sílica com o sistema Cojet (3M/ESPE) + Silano ESPE-Sil (3M/ESPE). Os blocos condicionados de cada grupo foram cimentados com Panavia F (Kuraray, CO) a blocos de resina composta ClearfilTM AP-X (Kuraray, CO) sob carga constante de 750g por 10 minutos. Foram determinados, portanto, seis grupos experimentais constituídos por conjuntos formados pela liga, cimento e resina composta. Estes foram cortados em uma máquina de corte obtendo-se por bloco cimentado 4 amostras com dimensões de 10x1x1mm sendo que a superfície adesiva apresentou aproximadamente 1mm2 de área. O teste de microtração foi realizado em máquina de testes universal (EMIC) com célula de carga de 10kgf e velocidade de 1mm/min. Cada grupo foi representado por quarenta amostras, entretanto cada grupo apresentou 10 valores médios de resistência adesiva em MPa (n=10), sendo que cada valor foi proveniente da média obtida a partir dos valores individuais das quatro amostras de cada conjunto de blocos cimentados. Os valores de resistência adesiva e os desvios-padrão (MPa) para os grupos foram : G1: 7,33 ± 1,93d; G2: 13,35 ± 2,18 c G3: 23,56 ± 6,5 b; G4:42,6 ± 5,84 a; G5: 26,17 ± 1,94 b; G6: 44,30 ± 2,3 a. Os dados de resistência adesiva foram analisados estatisticamente pelo teste de ....
Abstract: The aim of this study is to evaluate the hypothesis that different conditionings of surface of three dental alloys (Gold - Degudent U - Degussa; Nickel-chromium - Wiron 99, Bego; Titanium - Rematitan, Dentaurum) they do not modify the values of bond strength with a resin cement. Twenty blocks of each alloy with dimensions of 5x5x5mm were cast and divided in two subgroups of 10 blocks that were conditioned with the following surface treatments: TRAT. 1 - sandblasting with particles of oxide of aluminum 110μm (Al2O3) + Alloy Primer (Kuraray, CO) and TRAT. 2 - sandblasting with particles of oxide of silica with Cojet-Sand (3M/ESPE) + Silane (ESPE-SIL). The conditioned blocks of each group were luted with Panavia F (Kuraray, CO) to composite resin blocks of ClearfilTM AP-X (Kuraray, CO) under constant load of 750g for 10 minutes. Six experimental groups were constituted by sets formed by the alloy, cement and composite resin. The sets were split up in a mechanical lathe obtaining by block 4 samples with dimensions of 10x1x1mm and the adhesive surface with approximately 1mm2. The microtensile test was accomplished in an universal test machine (EMIC) with cell of load of 10kgf and crosshead speed of 1mm/min. Each group was represented by forty samples, however each group presented 10 means values of bond strength MPa (n=10), obtained from the mean of the individual values of the four samples of each cemented blocks. Means and standard deviation of bond strength (MPa) were: G1: 7.33 ± 1.93d; G2: 13.35 ± 2.18 c G3: 23.56 ± 6.5 b; G4:42.6 ± 5.84 a; G5: 26.17 ± 1.94 b; G6: 44.30 ± 2.3 a. The data of bond strength were analyzed by the analysis of variance test (ANOVA) and Tukey test, p<0.05. The results indicated that surface treatment 2 (Cojet) increased the bond strength between the resin cement and alloys. The smallest values of bond strength were obtained with gold alloy, independent of ....
Doutor
APA, Harvard, Vancouver, ISO, and other styles
37

Oliva, Eduardo Andrade de. "Influência do método de processamento na resistência à flexão, tração diametral e dureza dos sistemas cerâmicos /." Araraquara : [s.n.], 2003. http://hdl.handle.net/11449/97324.

Full text
Abstract:
Orientador: Carlos Alberto dos Santos Cruz
Banca: Luís Geraldo Vaz
Banca: Paulo Vicente Barbosa da Rocha
Resumo: O objetivo deste trabalho foi avaliar a resistência à flexão, a resistência à tração diametral e a dureza das cerâmicas feldspáticas AllCeram (processada por sinterização) e Cergogold (processada por injeção à vácuo) e Ceramco 2 (processada por sinterização convencional e por injeção). Foram confeccionadas dez amostras de cada grupo experimental para o ensaio de resistência à flexão (em forma de barra, 25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872) e 15 amostras para o ensaio de resistência à tração diametral (em forma de disco, 6mm de diâmetro, 3mm de espessura). Os testes foram realizados em equipamento MTS 810 (Material Test System, EUA), com célula de carga de 10kN e velocidade de 0,5mm/minuto, gerenciado por programa Test Star II (IBM, EUA). Para o ensaio de dureza, na escala Vickers, cinco fragmentos de cada grupo foram incluídos em resina acrílica autopolimerizável, polidos e submetidos ao teste no durômetro Buheler (EUA), com carga de 1,0kgf por 30 segundos. Dento da técnica de processamento indicada pelo fabricante, nos ensaios de resistência à flexão e dureza, os resultados apontaram igualdade estatística entre os materiais Ceramco 2 (73,75MPa / 478,8VNH) e Cergogold (68,96MPa / 495,3VHN); a seguir, com valores estatisticamente inferiores está a cerâmica All-Ceram (50,51MPa / 451VHN). No ensaio de resistência à tração diametral, houve igualdade estatística entre os 3 materiais: Ceramco 2 (34,15MPa), Cergogold (33,95MPa) e AllCeram (29,74MPa). Para a cerâmica Ceramco 2, o método de processamento sinterização ou injeção à vácuo não interferiu na resistência mecânica, apresentando valores com igualdade estatística para as três propriedades estudadas: respectivamente, resistência à flexão (73,75MPA, 77,88MPa), resistência à tração diametral (34,15MPa, 33,52MPa) e dureza ...(Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The aim of this study was to compare flexural strength, diametral tensile strength and hardness of ceramics AllCeram (convencional fusing), Cergogold (heat-pressed) and Ceramco 2 (convencional fusing and heat-pressed). Ten especimens were made for flexural test (25mm length; 5mm width; 2mm thick - ISO 6872), and 15 especimens for diametral test (6mm diameter, 3mm thick). The tests were done in a MTS 810 machine (Material Test System - USA), with load cell of 10kN and crosshead-speed of 0.5mm/minute, managed by Test Star II software (IBM, USA). Five samples of each ceramic were included in autocured resin JET (Artigos odontológicos Clássico, Brazil), polished and submitted to Vickers hardness test in duromer Buheler (USA), with load of 1.0kgf for 30 seconds. Manuffacturer' processing technique the mean flexural stengths and hardness was significantly similar for Ceramco 2(73,75MPa / 478,8VNH) and Cergogold (68,96MPa / 495,3VNH), and significantly stronger than AllCeram (50,51 / 451VNH). All materials did not differ for diametral tensile (AllCeram 29,74MPa; Cergogold, 33,95MPa; Ceramco 2, 34,15MPa). Effects of processing method (convencional fusing and heat-pressed) did not influenced on flexural strength (73,75MPa / 77,88MPa), diametral tensile strength (34.15 MPa / 33,52 MPa) and hardness (478,8VHN / 471,5VHN) of Ceramco 2. However, for Ceramco 2 (heat-pressed) flexural strength (77,88MPa) became significantly higher and hardness (471,5VHN) became significantly lower than Cergogold (68,96MPa, 495,3VHN).
Mestre
APA, Harvard, Vancouver, ISO, and other styles
38

Cortez, Douglas Giordani Negreiros. "Estudo in vivo da infiltração coronaria em dentes de cães tratados endodonticamente e protegidos por diferentes materiais." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289868.

Full text
Abstract:
Orientador: Alexandre Augusto Zaia
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T22:23:00Z (GMT). No. of bitstreams: 1 Cortez_DouglasGiordaniNegreiros_D.pdf: 24105426 bytes, checksum: d2a6f958d2f989ae6e14ff197ec69f42 (MD5) Previous issue date: 2005
Resumo: Este trabalho avaliou in vivo a infiltração coronária de microrganismos em dentes tratados endodonticamente, preparados para pino e com o remanescente obturador protegido ou não com diferentes materiais. Foram utilizados 136 canais de incisivos e pré-molares de 6 cães. Após a anestesia dos animais, os canais foram instrumentados. Cento e dois canais foram obturados pela técnica da condensação lateral.com cimento Sealapex e 34 canais foram obturados por .cone único de guta percha sem cimento. Em 68 canais obturados pela condensação lateral e nos 34 canais obturados sem cimento as obturações foram parcialmente removidas deixando um remanescente padronizado de 4mm. Diretamente sobre os remanescentes obturadores foram realizadas proteções com espessura de 2mm com: Coltosol ou resina composta "flow". Os demais canais tiveram as obturações parcialmente removidas deixando-as com 6mm e não receberam proteção. Os canais foram divididos em 8 grupos de 17 cada distribuídos da seguinte maneira: - grupos 1 e 5: proteção com resina composta flow; - grupos 2 e 6: proteção com Coltosol; - grupos 3 e 7: proteção com coltosol nas raízes obturadas com cone único sem cimento; - grupos 4 e 8: sem proteção. Devidamente preparados, os espécimes permaneceram com as obturações expostas à cavidade oral dos animais. Os grupos 1 a 4 foram avaliados -com 30 dias de exposição e os grupos 5 a 8 com 180 dias. Decorridos os tempos experimentais os animais foram mortos. Todos os espécimes foram avaliados radiograficamente quanto ao aparecimento de lesão periapical. Em cada grupo, 11 raízes destinadas ao estudo histológico foram removidas em bloco e devidamente processadas para histologia. Os demais espécimes foram extraídos e destinados a pesquisa da presença bacteriana por dois métodos, onde 3 raízes foram destinadas à cultura microbiológica e outras 3 foram clivadas transversalmente para a análise em Microscopia Eletrônica de Varredura (MEV). Radiograficamente não foi detectada lesão periapical em nenhum espécime. Na avaliação microbiológica apenas um espécime do grupo 7 apresentou -crescimento bacteriano. A avaliação em MEV não demonstrou infiltração bacteriana. Histologicamente com 30 dias nenhum espécime apresentou inflamação relacionada à infiltração coronária. Com ô meses o grupo 5 apresentou 2 espécimes com inflamação relacionada à infiltração coronária, os demais grupos apresentaram apenas 1 espécime cada com inflamação. A coloração de Brown e Brenn evidenciou microrganismos nos espécimes com inflamação. Os resultados permitiram concluir que o Coltosol foi eficiente na proteção das obturações e que a obturação do canal apresenta uma boa resistência à infiltração coronária in vivo por 180 dias
Abstract: This in vivo study evaluated the microbial coronal leakage in dogs endodontically treated teeth, post space preparation and with the remaining filling protected or not with different materiais. A hundred thirty six root canais of incisives and pre-molars of 6 dogs were used. After the anesthesia of the animais, these teeth were endodontically prepared. Hundred two canaIs were filled by lateral condensation technique and Sealapex sealer, and 34 canais were filled only with a single gutta-percha cone without sealer. In 68 canais filled by lateral-condensation and in the 34 canais filled without sealer, the fillings were partially removed leaving standardized 4mm. Directly on the remaining obturations, protections with 2mm of thickness were done with Coltosol or Composite " flow ". The obturations of the other canais were partially removed leaving them with 6mm and didn't receive protection. The canais were divided in 8 groups of 17 .each distributed in the following way: - groups 1 and 5: protection with composite flow; - groups 2 and 6: protection with Coltosol; - groups 3 and 7: protection with coltosol in the roots filled with a single cone without sealer; - groups 4 and 8: without protection. Properly prepared, the specimens stayed with the fillings exposed to the oral cavity of the animais. The groups 1 to 4 were evaluated with 30 days of exposition and the groups 5 to 8 with 180 days. In the end of the experimental times the animais were killed. Ali the specimens were radiographically appraised about the appearance of periapical lesions. In each group, 11 roots destined to the histological evaluation were removed in block and properly processed for histology. The other specimens were extracted and destined to bacterial research by two methods. In 3 roots microbiologic culture was accomplished and the other 3 were transverselly fractured to Scanning Electronic Microscopy (SEM) analysis. Periapicallesion was not radiographically detected in any specimen. In the microbiologic evaluation only one specimen of the group 7 presented bacterial growth. The SEM evaluation did not demonstrate bacterial leakage. Histologically, at 30 days, no -specimen presented inflammation related to coronal leakage. With 6 months the group 5 presented 2 specimens with inflammation related to the coronal leakage, the other groups presented only 1 specimen each with inflammation. The Brown and Br.enn stain evidenced microrganisms in the specimens with inflammation. The r.esults allowed to conclude that Coltosol was efficient in the protection of the obturations and that theroot canal filling presents a good resistance to coronalleakage in vivo up to 180 days
Doutorado
Endodontia
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
39

Naoe, Hilka Tiemi. "Influencia dos tipos de tratamentos sobre a resistencia de união entre dentes e resinas acrilicas." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288557.

Full text
Abstract:
Orientador: Rafael Leonardo Xediek Consani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-12T19:07:37Z (GMT). No. of bitstreams: 1 Naoe_HilkaTiemi_M.pdf: 1024541 bytes, checksum: 92dfb7adacf4acd2b08826fb3278ce7c (MD5) Previous issue date: 2009
Resumo: O objetivo neste estudo foi verificar a resistência da união ao cisalhamento entre as resinas acrílicas Clássico ou Onda-Cryl e o dente Trubyte-Biotone, sob a influência de diversas formas de retenção, compreendendo nenhum tratamento (controle), perfuração com broca, jateamento com partículas de óxido de alumínio, condicionamento com monômero, condicionamento com primer e interações. Noventa matrizes retangulares, medindo 20mm de largura por 35mm de comprimento, foram confeccionadas com cera utilidade e incluídas na parte inferior de muflas metálicas ou plásticas, com gesso pedra tipo III Herodent. As matrizes retangulares foram removidas depois de plastificadas com água em ebulição e os moldes de gesso revestidos com silicone laboratorial, nos quais foram incluídos um dente molar com a base contendo um cilindro de cera de 6mm de diâmetro por 25mm de comprimento. O conjunto dente-cilindro em cera foi recoberto com uma camada de silicone e a mufla preenchida com gesso pedra. Depois da presa do gesso, o conjunto dente-cilindro em cera foi removido, o bastão em cera retirado, o dente limpo com detergente e as bases submetidas aos tratamentos de acordo com o protocolo e recolocadas nos moldes de silicone. As resinas acrílicas termopolimerizáveis foram proporcionadas na relação volumétrica de 3/1 (polímero/monômero), adaptadas na fase plástica nos moldes de silicone e prensadas em prensa hidráulica de bancada. As muflas metálicas foram levadas à termopolimerizadora automática para polimerização da resina no ciclo em banho de água à temperatura de 74ºC durante 9 horas. As muflas plásticas foram colocadas em forno de microondas para polimerização da resina, calibrado com 900W de potência, para o ciclo de: fase I - 3 minutos com 40% da potência, fase II - 4 minutos com potência 0% e fase III - 3 minutos com 90% da potência e esfriamento das muflas em bancada. Depois da demuflagem, os corpos-de-prova foram armazenados em água destilada à temperatura de 37ºC durante 24 horas. Depois da armazenagem, os corpos-de-prova foram submetidos ao teste de resistência ao cisalhamento na máquina de ensaios universal Instron, com velocidade de 1mm/minuto. Os resultados submetidos à análise de variância e as médias ao teste de Tukey (5%) mostraram que os valores da união entre dentes artificiais e resinas acrílicas não apresentam diferença estatística significativa, quando comparadas independentemente dos tipos de tratamentos. Na análise dos tipos de tratamentos, independentemente da resina acrílica, o grupo que recebeu jateamento+adesivo apresentou média com diferença estatística significativa com o grupo perfurado+adesivo. Os demais grupos não apresentaram diferença estatística significativa. Quando os tratamentos foram considerados em cada resina, na Clássico não houve diferença significativa entre eles e na Onda-Cryl os tratamentos controle e perfurado+adesivo foram diferentes estatisticamente dos grupos jateado+ monômero e jateado+adesivo. Os demais grupos não apresentaram diferenças estatísticas. Na comparação entre resinas, somente o grupo controle apresentou diferença estatística significativa com o maior valor para a resina Onda-Cryl
Abstract: The purpose of this study was to verify the shear bond strength between denture tooth Trubyte-Biotone and the acrylic resins Clássico and Onda-Cryl, under the influence of various forms of treatments, including no treatment (control), retention groove, sandblasting with aluminum oxide particles, monomer application, primer application, and interactions. Ninety wax rectangular mold patterns (20 mm in width and 35 mm in length), were poured into a traditional brass flask or metal with type III dental stone that was proportioned and manipulated following the manufacturer's recommendations. After wax patterns removal, the stone mold was filled with a layer of laboratory silicone putty. Identical model acrylic molar teeth with a wax stick (6mm diameter and 25mm long) attached at the ridge lap surface were partially embedded into the silicone layer. The resultant tooth/wax stick set was then covered with a layer of laboratory silicone putty. After dental stone isolation with petroleum jelly, the flask was completely poured with type III dental stone and pressed in a hydraulic press bench. Following, the tooth/wax stick set was deflasked and the wax stick removed from the tooth ridge lap. The tooth was brushed with a solution of hot water and liquid detergent to eliminate the wax residuos. Heat-cured denture base acrylic resins were prepared using a ratio of volume 3/1(polymer/monomer), adapted on stage in plastic molds made of silicon and pressing into bench hydraulic press. The metal flask were conventional packed, polymerized in a hot water bath at 74oC for 9 hours in polymerizing unit, and deflasked after flask cooling at room temperature. The plastic flask were placed in the microwave oven for curing the acrylic resin, calibrated with 900W of power for the cycle: Phase I - 3 minutes with 40% of the power, phase II - 4 minutes with 0% power and phase III - 3 minutes with 90% of the power and flask cooling at room temperature. After deflasked, all specimens were stored in distilled water at a temperature of 37oC for 24 hours, and they were performed the shear bond testing in an Instron machine, using a cross-speed of 1mm/minuto. The results were submitted to ANOVA and Tukey's test (5%) showed that the values of the shear bond strength between artificial teeth and acrylic resins were not statistically significant when compared regardless of the types of treatments. In the treatment type analysis, regardless of acrylic resin, the sandblasting+adhesive group showed bond strength values with significant statistically difference when compared to groove+adhesive group. The other experimental groups were not statistically different. When the treatments were considered in each resin, in the Classico acrylic resin there was no significant difference between them. In Onda-Cryl, control and groove+adhesive treatments were statistically different of the sandblasting+monomer and sandblasting+adhesive groups, while the other showed no statistical differences. In the comparison between resins, only the control group showed statistically significant differences, with the greatest value for the Onda-Cryl acrylic resin
Mestrado
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
40

Sfalcin, Ravana Angelini 1985. "Análise da penetração de materiais resinosos experimentais em lesões iniciais de cárie em esmalte por meio de microscopia confocal." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288588.

Full text
Abstract:
Orientador: Regina Maria Puppin Rontani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-17T23:15:14Z (GMT). No. of bitstreams: 1 Sfalcin_RavanaAngelini_M.pdf: 1330489 bytes, checksum: abc6987e3821135b4fb9e477a2ae52cc (MD5) Previous issue date: 2011
Resumo: O objetivo deste trabalho foi avaliar a penetração de materiais resinosos experimentais de baixa viscosidade em lesões artificiais sub-superficiais de cárie em esmalte (LASCE), por meio de Microscopia Confocal de Varredura a Laser (MCVL). Cinquenta e cinco terceiros molares humanos extraídos e livres de cárie foram selecionados. Blocos da superfície oclusal foram obtidos e distribuídos em 11 grupos (n=5), dos quais 5 blocos foram mantidos hígidos (Grupo Controle Positivo) e os demais submetidos a produção de cárie in vitro. Os blocos de esmalte oclusal cariados foram distribuídos aleatoriamente de acordo com a composição do material em: Grupo Controle Negativo (dente cariado); G1: 100% TEGDMA, G2: 80% TEGDMA + 20% etanol, G3: 80% TEGDMA + 20% HEMA, G4: 75% TEGDMA + 25% UDMA, G5: 60% TEGDMA + 20% UDMA + 20% etanol, G6: 60% TEGDMA + 20% UDMA + 20% HEMA, G7: 75% TEGDMA + 25% BisEMA, G8: 60% TEGDMA + 20% BisEMA + 20% etanol e G9: 60% TEGDMA + 20% BisEMA + 20% HEMA. Os materiais experimentais foram impregnados com corante isotiocianato de rodamina B a 0,1 % anterior a aplicação na superfície oclusal, e após fotoativado (40 s), os blocos foram seccionados em fatias de 0,5 mm, e estas foram deixadas em solução etanólica de fluoresceína de sódio 100 ?M por 3 min, para visualização em Microscopia Confocal de Varredura a Laser. A análise das imagens foi feita através do programa LAS AF Lite, e em seguida as médias de intensidade foram convertidas em porcentagem pelo Microsoft Excel. Os valores de porcentagem obtidos foram submetidos a análise de variância e teste de Tukey, em nível de significância de 5%. Os resultados mostraram que a maior média de intensidade de fluorescência, indicando o maior percentual de preenchimento ocorrido na lesão de cárie, ocorreu no G7, enquanto o menor valor foi obtido pelo grupo G5. Pode-se concluir que diferentes concentrações monoméricas e composição de misturas em composto resinoso de baixa viscosidade produzem diferentes percentuais de penetração e preenchimento de lesões cariosas em esmalte. Os maiores valores de preenchimento das lesões foram obtidos com a mistura TEGDMA+BisEMA e os mais baixos para TEGDMA+UDMA+etanol
Abstract: The aim of this study was to evaluate the penetration of low viscosity experimental resin materials containing different combinations of resin monomers/diluents in enamel-like caries lesions using Confocal Laser Scanning Microscopy (CLSM). Nine experimental resin materials containing TEGDMA as a base monomer and varying the other monomers and solvents BisEMA, HEMA, UDMA and ethanol were prepared in different proportions. Fifty and five sound and extracted third human molars were used. The crown fragments were obtained and distributed in 11 groups (n=5), which 5 crown fragments were maintained sound (Positive Control Group) and the others were submitted to in vitro lesion caries production. The crown fragments were distributed randomly according to material composition: Negative Control Group (carious teeth); Carious and infiltrated blocks: G1: 100% TEGDMA, G2: 80% TEGDMA + 20% ethanol, G3: 80% TEGDMA + 20% HEMA, G4: 75% TEGDMA + 25% UDMA, G5: 60% TEGDMA + 20% UDMA + 20% ethanol, G6: 60% TEGDMA + 20% UDMA + 20% HEMA, G7: 75% TEGDMA + 25% BisEMA, G8: 60% TEGDMA + 20% BisEMA + 20% ethanol and Group 9: 60% TEGDMA + 20% BisEMA + 20% HEMA. Experimental materials were labeled with the red fluorophore rhodamine B isothiocyanate (RITC 0,1%; Sigma Aldrich, Steinheim, Germany) prior to the application on occlusal surface, and after light cured (40 s), 0,5 mm thin sections were prepared and immersed in a 50% ethanolic solution of 100 ?M sodium fluorescein (NaFL, Sigma Aldrich) for 3 min, to confocal microscopy visualization. Analysis of images was made by program LAS AF Lite, then, intensity means were converted in percentage by Microsoft Excel. Percentage values obtained were submitted to ANOVA Tukey's test, at significance level of 5%. Results showed that that the highest mean of fluorescence intensity, indicating fulfilling percentage penetration occurred into caries lesion, was obtained in the G7, while lower value was obtained by G5. It could be concluded that different monomeric concentrations and composition of low viscosity resin blends produce different percentage of penetration and fulfilling of initial enamel-like caries lesions. The best results were obtained for TEGDMA+BisEMA and the lowest results for TEGDMA+UDMA+ethanol
Mestrado
Materiais Dentarios
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
41

Araújo, Tatiany Gabrielle Freire 1984. "Resistência de união de materiais resinosos de baixa viscosidade em lesões incipientes de cárie em esmalte." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288608.

Full text
Abstract:
Orientador: Regina Maria Puppin-Rontani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-17T23:43:51Z (GMT). No. of bitstreams: 1 Araujo_TatianyGabrielleFreire_M.pdf: 1655802 bytes, checksum: 6a47f7f2b524f4184895f4492c916f31 (MD5) Previous issue date: 2011
Resumo: A infiltração de resinas de baixa viscosidade (infiltrantes) em lesões incipientes de cárie em esmalte parece ser uma abordagem promissora na odontologia apresentando vantagens em relação à remineralização ou tratamentos invasivos. Para isso o material deve penetrar e selar a entrada das lesões, reforçando a estrutura cariada e eventualmente impedindo a progressão da lesão, com capacidade de manter a resistência de união duradoura com o esmalte cariado. O objetivo do trabalho foi avaliar a resistência de união de resinas experimentais de baixa viscosidade com diferentes composições sobre a lesão de cárie incipiente em esmalte pelo teste de micro tração. Noventa terceiros molares humanos inclusos foram utilizados. As raízes dos dentes foram seccionadas e os fragmentos coronários foram lixados e seccionados, mesio-distalmente, para produção da lesão artificial, subsuperficial de cárie de esmalte. Cada espécime foi mantido individualmente em 50 mL de solução produtora de cárie, durante 10h a 37ºC. Os amostras foram distribuídos aleatoriamente em 9 grupos compostos por 10 dentes (n = 10) de acordo com a composição do material resinoso de baixa viscosidade (Grupo 1: TEGDMA 100%, Grupo 2: TEGDMA 80% + etanol 20%, Grupo 3 : TEGDMA 80% + HEMA 20%, Grupo 4: TEGDMA 75% + UDMA 25%, Grupo 5: TEGDMA 60% + UDMA 20% + etanol 20%, Grupo 6 : TEGDMA 60% + UDMA 20% + HEMA 20%, Grupo 7: TEGDMA 75% + BisEMA 25%, Grupo 8: TEGDMA 60% + BisEMA 20% + etanol 20% e Grupo 9: TEGDMA 60% + BisEMA 20% + HEMA 20 %). Os resultados mostraram que os maiores valores de resistência de união foram observados para G1, G3, G4, G6 e G7. Os valores intermediários de resistência de união foram para G2, G5 e G9. O grupo G8 apresentou o menor valor de resistência de união. Pode se concluir que os materiais infiltrantes com composição livre do solvente etanol, apresentaram maiores valores de resistência de união ao esmalte cariado
Abstract: Infiltration of enamel-like initial caries lesions with low viscosity resins (infiltrants) seems to be a promising approach in dentistry and it have showed advantages regarding to remineralization or invasive treatments. In this way, material must penetrate and seal lesions intake, reinforcing carious structure and eventually avoiding lesion progression, with capacity in maintaining a long-term strength bond with carious enamel. The aim of this study was to evaluate bond strength of experimental low viscosity resins with different compositions of monomers over artificial enamel caries lesions by micro tensile bond strength test. Ninety human molars third without caries were used. Tooth root were cut and crown fragments were polished and cut, in mesio-distal sense, for the enamel-like initial caries lesions production. Each specimen was immersed individually in 50 mL of caries former solution, during 10 h at 37°C. Specimens were distributed randomly in 9 groups (n=10), according to low viscosity experimental material composition (Group 1: TEGDMA 100%, Group 2: TEGDMA 80% + ethanol 20%, Group 3: TEGDMA 80% + HEMA 20%, Group 4: TEGDMA 75% + UDMA 25%, Group 5 : TEGDMA 60% + UDMA 20% + ethanol 20% , Group 6: TEGDMA 60% + UDMA 20% + HEMA 20%, Group 7: TEGDMA 75% + BisEMA 25%, Group 8: TEGDMA 60% + BisEMA 20 % + ethanol 20%, Group 9 : TEGDMA 60% + BisEMA 20% + HEMA 20%). Results showed that higher values of bond strength were observed to the groups G1, G3, G4, G6 and G7. Intermediate values of bond strength were observed to G2, G5 and G9. Group G8 showed lower mean value of bond strength. It could be concluded that the use of infiltrant materials with composition without ethanol solvent showed higher value of bond strength on the carious enamel
Mestrado
Materiais Dentarios
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
42

Marchiori, André Vinícius. "Reação exotérmica e expansões de presa e térmica de revestimentos frente às técnicas de fundição convencional e rápida /." Araçatuba : [s.n.], 2007. http://hdl.handle.net/11449/105583.

Full text
Abstract:
Orientador: Eulália Maria Martins da Silva
Banca: Wirley Gonçalves Assunção
Banca: Paulo Henrique dos Santos
Banca: Osvaldo Luiz Bezzon
Banca: Paulo Martins Ferreira
Resumo: Os protocolos estabelecidos numa técnica de fundição objetivam compensar a contração de solidificação da liga metálica e obter estruturas metálicas fundida com adequada adaptação cervical. A técnica de fundição rápida tem demonstrado ser uma alternativa, mas há dúvidas sobre como os revestimentos se expandem. Este estudo comparou as expansões de presa, térmica e total de três revestimentos odontológicos perante os procedimentos realizados em técnicas de fundição convencional e rápida. Na primeira parte desse estudo, determinaram-se as curvas das expansões resultantes da reação exotérmica de presa (n=5/revestimentoXtécnica), juntamente com as curvas de temperaturas que permitiram determinar o pico da exotermia e o intervalo médio requerido por cada revestimento para atingí-lo e; na segunda parte, aferiu-se a expansão térmica (n=3/revestimento). Para a análise estatística, utilizou-se o ANOVA e o Teste de Tukey (p<0,05). O maior valor médio de temperatura durante a presa foi determinado para o revestimento Micro Fine 1700 (88oC), que não diferiu estatisticamente do Heat Shock (80,3oC) e o menor, para o All Therm (67oC). O Micro Fine 1700 foi o que atingiu seu pico máximo de temperatura mais precocemente (5,8min), seguido pelo Heat Shock (16,4min) e o All Therm (18,8min), sendo todos diferentes entre si (p<0,05). Pôde-se constatar que os três revestimentos avaliados atingiram seus respectivos picos de temperatura num tempo menor ou igual a 20 minutos. Quanto à expansão de presa, para os revestimentos fosfatados foi muito menor no tempo de 20 minutos (tempo de espera para presa na técnica de fundição rápida) em comparação ao que se obteve com 60 minutos; o que não ocorreu, estatisticamente, para o revestimento cerâmico Micro Fine 1700. Só o revestimento cerâmico Micro Fine 1700 apresentou sua expansão de presa estabilizada aos 20 minutos.
Abstract: The protocols established in casting techniques aimed to compensate the solidification contraction of metallic alloy and to get casting metallic structures with accurate marginal fit. The accelerated casting technique has demonstrated to be an alternative, but some doubts regarding investment expansion remains. This study compared the curves of temperatures resultant setting expansion and expansions of setting, thermal and total of three dental investments before the conventional and accelerated casting techniques. In the first part of this study, the curves of the resultant expansion of the setting exothermic reaction (n=5/investment) were determined, together with the curves of temperatures. Based on theses temperatures curves either the maximum exothermic setting reaction temperature, and the mean time interval required for each investment were calculated. In the second part, thermal expansion (n=3/investmentXtechnique) was analyzed. ANOVA and Tukey Test were used as a statistic analysis at 5% level of significance. Micro Fine 1700 investment showed the highest temperature values during the setting (88oC), and did not differ significantly from the Heat Shock (80.3oC) (p>.05). All Therm exhibited lower values (67oC) that differed from the two other investments (p<.05). Micro Fine 1700 reached the maximum exothermic setting reaction temperature first (5.8min), followed by Heat Shock (16.4min) and All Therm (18.8min) (p<.05). It can be evidenced that the three investments had reached their temperature peak until 20 minutes. The setting expansions of the phosphate bonded investments were very lower in the time of 20 minutes (wait time for setting in the accelerated casting technique) in comparison to 60 minutes. However, this difference did not occur to Micro Fine 1700 ceramic investment (p>.05). Analyzing thermal expansion, only Heat Shock showed statistic difference regarding technique factor.
Doutor
APA, Harvard, Vancouver, ISO, and other styles
43

Prado, Rodrigo Diniz do. "Efeito do envelhecimento em baixa temperatura e desgaste no comportamento mecânico de uma cerâmica Y-TZP com duas espessuras diferentes indicada para restauração monolítica /." São José dos Campos, 2016. http://hdl.handle.net/11449/148775.

Full text
Abstract:
Orientador: Luiz Felipe Valandro
Coorientador: Marco Antonio Bottino
Banca: João Paulo Barros Machado
Banca: Guilherme de Siqueira Ferreira Anzaloni Saavedra
Resumo: O objetivo deste estudo foi avaliar o efeito do desgaste com broca diamantada, o envelhecimento (degradação em baixa temperatura) e espessura do material cerâmico no comportamento mecânico de uma cerâmica Y-TZP. Para este estudo, 240 espécimes foram fabricados em formato de disco, de acordo com a norma ISO 6872: 2008 para resistência à flexão biaxial de amostras de cerâmica (N = 120, com dimensões de 0,5 mm de espessura x 15 mm de diâmetro; N = 120 com a dimensão 1,0 milímetros de espessura x diâmetro 15 mm). Os espécimes foram divididos aleatoriamente em 8 grupos (n = 30), de acordo com três fatores em estudo: 'desgaste' em 2 níveis (com e sem desgaste com broca diamantada), o envelhecimento em 2 níveis (com e sem envelhecimento) e da espessura da cerâmica também em 2 níveis (0,5 a 1,0 mm). O desgaste foi realizado com uma broca diamantada montada em um motor de baixa rotação associado a um contra-ângulo multiplicador de velocidade (T2 REVOR R170, Sirona, Bensheim, Alemanha), sob constante irrigação de água. O envelhecimento foi simulado em uma autoclave à temperatura de 134 °C, durante um período de 20 horas, sob pressão de 2 bar. Após o desgaste e envelhecimento, análises de rugosidade e topográficas foram realizadas e análises de transformação de fase por difração de raios-X. Os dados coletados foram submetidos à análise de Weibull. O desgaste promoveu um aumento da rugosidade, enquanto que o envelhecimento em autoclave não afetou estatisticamente a rugosidade da superfíc... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The goals of this investigation were to evaluate the effects of grinding with diamond bur and aging (low temperature degradation) on the mechanical behavior of a fullcontour Y-TZP ceramic with two thicknesses. Y-TZP shaped-disc specimens (Zirlux FC, Ardent Dental) were manufactured with thickness of 0.5 mm and 1.0 mm (both with 15 mm in diameter). The specimens from every thickness were randomly assigned into 4 groups, according to two factors: 'grinding' on 2 levels (with and without grinding with diamond bur), aging in 2 levels (with and without aging). Grinding was performed with a diamond bur mounted in a slow speed rotation motor associated with a counter-angle speed multiplier hand-piece, under constant watercooling. Low temperature aging was performed in an autoclave at 134°C temperature, for a period of 20h, under 2 bar of pressure. After grinding and aging, roughness analyzes were performed on a surface roughness tester and 3D digital optical profilometer; topographic analysis were made in a scanning electron microscope; phase transformation analysis by X-ray diffraction. Biaxial flexural strength tests were performed in the universal testing machine. Specific statistical analyses were carried out (Weibull analysis for the strength data). Grinding promoted an increase in roughness, while aging in autoclave did not affect statistically the surface roughness. Also, grinding and aging lead to higher values of m-phase content, although, grinding lead to a decrease in the material susceptibility to a new phase transformations during aging (after aging, as-sintered condition resulted in higher m-phase content compared with ground). Independent on the zirconia's thickness, aging in autoclave and grinding led to an increase in characteristic strengths. Within the limits of this study, it was observed that: grinding and low ...(Resumo completo, clicar acesso eletrônico abaixo)
Mestre
APA, Harvard, Vancouver, ISO, and other styles
44

Naressi, Suely Carvalho Mutti [UNESP]. "Estudo comparativo de resistência ao cisalhamento em reconstruções com amálgama, utilizando como procedimento retentivo pino rosqueável, amalgapin e adesivo dentário." Universidade Estadual Paulista (UNESP), 1995. http://hdl.handle.net/11449/113958.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:25Z (GMT). No. of bitstreams: 0 Previous issue date: 1995-06-06Bitstream added on 2015-01-26T13:30:30Z : No. of bitstreams: 1 000026436.pdf: 2385135 bytes, checksum: 6eb3ae5068a2873e6fcff35962e5dfb0 (MD5)
Objetivando evitar perda de dentes posteriores com grandes destruições coronárias, este trabalho comparou, mediante termociclagem e testes laboratoriais, a resistência ao cisalhamento entre três procedimentos retentivos de reconstrução com amálgama em dentes pré-molares com preparo tipo flat: pino rosqueável, amalgapin e amálgama adesivo. Os valores resultantes da ação das forças e a análise das falhas, visualmente e em microscopia ótica estereoscópica, permitiram inferir que o melhor procedimento retentivo ocorreu com pino rosqueável, seguido do amalgapin. A técnica do amálgama adesivo, com o material por nós utilizado, apresentou-se ineficaz como único procedimento retentivo neste tipo de reconstrução
In order to avoid the loss of largely destroyed crowns of posterior teeth, this study dealt with laboratory tests to compare the resistance to shear strengths application among three retentive procedures for amalgam buildups: adhesive amalgam, amalgapin and threadned pin. The failures resultant from the strength action, analysed visually and stereoscopic otic microscopy, permitted to conclude that the best retentive procedure happened with threadned pin, followed by amalgapin. The adhesive amalgam restoration technique was considered non-efficient, for the adhesive used, as the only retentive procedure in this kind of buildup
APA, Harvard, Vancouver, ISO, and other styles
45

Andreatta, Filho Osvaldo Daniel [UNESP]. "Avaliação da resistência adesiva entre a superfície de uma cerâmica aluminizada e um cimento resinoso." Universidade Estadual Paulista (UNESP), 2003. http://hdl.handle.net/11449/113973.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-06-16Bitstream added on 2015-01-26T13:30:28Z : No. of bitstreams: 1 000200252.pdf: 4826015 bytes, checksum: 2d68716152cb183fffad313962f0dd68 (MD5)
Este trabalho teve como objetivo avaliar o efeito da ciclagem térmica sobre a resistência adesiva entre a superfície de uma cerâmica aluminizada (Procera AIICeram, Nobei-Biocare) e um cimento resinoso (Panavia F, Kuraray CO). Foram confeccionados nove blocos de cerâmica, com dimensões de 5x6x6mm, sendo que uma das faces, com dimensões de 5x6mm de cada bloco, foi condicionada com uma cobertura triboquimica de sílica (Sistema Rocatec, ESPE). A seguir foram cimentados a blocos de resina composta (Clearfil AP-X, Kuraray CO), obtidos a partir da duplicação dos blocos Cerâmicos moldados com silicona de adição (Express, 3M). Em seguida, os conjuntos cerâmica-cimento resina foram cortados obtendo-se 75 corpos-de-prova com formato retangular com dimensões de 12x1x1mm e superfície adesiva apresentando 1mm2 ± 0, 1mm2. Os corpos-de-prova foram divididos em três grupos (n=25): G1 - armazenagem por 14 dias em água destilada a 37°C, G2- 6000 ciclos térmicos em água (5°C e 55°C) e G3 - ciclagem térmica a 12000 ciclos em água (5°C e 55°C). Após os períodos de armazenagem e ciclagem os corpos-de-prova foram fixados com adesivo de cianoacrilato ao dispositivo de microtração e ensaiados sob velocidade de 1 mm/min em máquina de ensaio universal (EMIC). Os dados foram tratados estatisticamente pela Anova e pelo teste de Tukey e indicaram que os valores médios de tensão de rupturas (MPa) de G1 (10,710 ± 3,54) não diferiram estatisticamente (p< 5%) de G2 (9,019 ± 3,90), porém houve diferença significativa entre G1 e G3 (7 ,280 ± 3,00). Concluiu-se que a ciclagem térmica diminuiu os valores de resistência adesiva significativamente quando os corpos-de-prova foram submetidos a 12000 ciclos
The aim of this study was to evaluate the effect of thermocycling on the bond strength between the surface of Procera AllCeram (Nobel-Biocare) and the resin cement (Panavia F, Kuraray CO). Nine ceramic blocks were fabricated with dimensions of 5x6x6mm. One of the faces with 5x6mm of each ceramic block was conditioned with a tribochemical silica coating (Rocatec system, Espe) and after it was luted with Panavia F to another identical block made from composite resin (Clearfil AP-X, Kuraray CO) obtained through duplication of the ceramic blocks with addition sílicona impression material (Express, 3M). The nine groups formed by ceramic, cement and composite resin were split up obtained 75 samples with dimensions of 12x1 x1 mm and adhesive surface presenting 1mm2±0,1mm2 of area. The samples were divided into 3 groups (n=25): G1 - stored for 14 days in distilled water at 37°C; G2- thermocycling for a total of 6000 cycles (5°C- 55°C); G3 - thermocycling for a total of 12000 cycles (5°C- 55°C). After conditioned times the samples were fixed with clanoacrilate adhesive at microtensile device and tested ín a universal testing machine (EM/C) at a crosshead speed of 1 mm/min. Data were analysed by ANOVA and Tukey test. The results indicated that the mean values of rupture tension (MPa) of G1 (10. 710 ± 3.54) they didn't differ estatisticaty (p <5%) of G2 (9.019 ± 3.90), however there was significant difference between G1 and G3 (7.280 ± 3.00). lt was possible to conclude that the themocycling reduced the values of bond strength significantly when samples were submitted to 12000 cycles
APA, Harvard, Vancouver, ISO, and other styles
46

Andreatta, Filho Osvaldo Daniel. "Avaliação da resistência adesiva entre a superfície de uma cerâmica aluminizada e um cimento resinoso /." São José dos Campos, 2003. http://hdl.handle.net/11449/113973.

Full text
Abstract:
Orientador: Maria Auxiliadora Junho de Araújo
Banca: Lourenço Correr Sobrinho
Banca: Renato Sussumu Nishioka
Resumo: Este trabalho teve como objetivo avaliar o efeito da ciclagem térmica sobre a resistência adesiva entre a superfície de uma cerâmica aluminizada (Procera AIICeram, Nobei-Biocare) e um cimento resinoso (Panavia F, Kuraray CO). Foram confeccionados nove blocos de cerâmica, com dimensões de 5x6x6mm, sendo que uma das faces, com dimensões de 5x6mm de cada bloco, foi condicionada com uma cobertura triboquimica de sílica (Sistema Rocatec, ESPE). A seguir foram cimentados a blocos de resina composta (Clearfil AP-X, Kuraray CO), obtidos a partir da duplicação dos blocos Cerâmicos moldados com silicona de adição (Express, 3M). Em seguida, os conjuntos cerâmica-cimento resina foram cortados obtendo-se 75 corpos-de-prova com formato retangular com dimensões de 12x1x1mm e superfície adesiva apresentando 1mm2 ± 0, 1mm2. Os corpos-de-prova foram divididos em três grupos (n=25): G1 - armazenagem por 14 dias em água destilada a 37°C, G2- 6000 ciclos térmicos em água (5°C e 55°C) e G3 - ciclagem térmica a 12000 ciclos em água (5°C e 55°C). Após os períodos de armazenagem e ciclagem os corpos-de-prova foram fixados com adesivo de cianoacrilato ao dispositivo de microtração e ensaiados sob velocidade de 1 mm/min em máquina de ensaio universal (EMIC). Os dados foram tratados estatisticamente pela Anova e pelo teste de Tukey e indicaram que os valores médios de tensão de rupturas (MPa) de G1 (10,710 ± 3,54) não diferiram estatisticamente (p< 5%) de G2 (9,019 ± 3,90), porém houve diferença significativa entre G1 e G3 (7 ,280 ± 3,00). Concluiu-se que a ciclagem térmica diminuiu os valores de resistência adesiva significativamente quando os corpos-de-prova foram submetidos a 12000 ciclos
Abstract: The aim of this study was to evaluate the effect of thermocycling on the bond strength between the surface of Procera AllCeram (Nobel-Biocare) and the resin cement (Panavia F, Kuraray CO). Nine ceramic blocks were fabricated with dimensions of 5x6x6mm. One of the faces with 5x6mm of each ceramic block was conditioned with a tribochemical silica coating (Rocatec system, Espe) and after it was luted with Panavia F to another identical block made from composite resin (Clearfil AP-X, Kuraray CO) obtained through duplication of the ceramic blocks with addition sílicona impression material (Express, 3M). The nine groups formed by ceramic, cement and composite resin were split up obtained 75 samples with dimensions of 12x1 x1 mm and adhesive surface presenting 1mm2±0,1mm2 of area. The samples were divided into 3 groups (n=25): G1 - stored for 14 days in distilled water at 37°C; G2- thermocycling for a total of 6000 cycles (5°C- 55°C); G3 - thermocycling for a total of 12000 cycles (5°C- 55°C). After conditioned times the samples were fixed with clanoacrilate adhesive at microtensile device and tested ín a universal testing machine (EM/C) at a crosshead speed of 1 mm/min. Data were analysed by ANOVA and Tukey test. The results indicated that the mean values of rupture tension (MPa) of G1 (10. 710 ± 3.54) they didn't differ estatisticaty (p <5%) of G2 (9.019 ± 3.90), however there was significant difference between G1 and G3 (7.280 ± 3.00). lt was possible to conclude that the themocycling reduced the values of bond strength significantly when samples were submitted to 12000 cycles
Mestre
APA, Harvard, Vancouver, ISO, and other styles
47

Moraes, Fernanda Gomes de. "Influência do EDTA, laser de ND:YAG e da combinação de ambos sobre a dentina radicular e na obturação de canais laterais." Universidade de São Paulo, 2003. http://www.teses.usp.br/teses/disponiveis/25/25138/tde-06102004-155820/.

Full text
Abstract:
Objetivou-se avaliar a influência do EDTA, laser de Nd:YAG e da combinação de ambos nas superfícies das paredes dentinárias e na obturação de canais laterais artificiais. Foram utilizados 54 pré-molares inferiores com 1 raiz e 1 canal radicular. Suas coroas foram removidas e três canais laterais artificiais foram confeccionados nos três terços de uma das faces proximais de cada uma dessas raízes com um alargador com diâmetro referente a uma lima do tipo K número 15. Preparado os canais laterais, os canais principais foram instrumentados com limas do tipo K no terço apical, até a de nº 40, e com brocas de Gattes Glidden nos terços cervical e médio. A irrigação foi feita com hipoclorito de sódio a 1% a cada troca de instrumento e uma irrigação final com soro fisiológico. As raízes foram divididas em 3 grupos com 18 raízes em cada um, em função dos tratamentos a que foram submetidas as paredes dos canais: Grupo1 - aplicação de EDTA por 5 minutos, agitação com instrumento de memória, irrigação final com soro fisiológico; Grupo 2 - 4 aplicações de laser de Nd:YAG com 15 Hz, 100 mJ e 1,5 Watts com movimentos helicoidais, em cada dente e Grupo 3 - aplicação de EDTA nos moldes do Grupo1 e, após essa etapa, aplicação do laser de Nd:YAG conforme o Grupo 2. Das 18 raízes, 3 foram preparadas para análise ao M.E.V. e as 15 restantes tiveram os canais obturados. A obturação foi feita com guta-percha e cimento AH Plus utilizando a técnica Híbrida de Tagger. Após a obturação foram feitas tomadas radiográficas das raízes para análise da obturação dos canais laterais artificiais. As raízes que foram reservadas para observação ao M.E.V., foram seccionadas longitudinalmente e, então, preparadas para as fotomicrografias onde se procurou evidenciar as embocaduras dos canais laterais e os túbulos dentinários, em cada terço. A análise dos resultados demonstrou não haver diferenças estatisticamente significantes (p > 0,05) entre os procedimentos realizados e nem em relação à obturação dos canais laterais artificiais. As fotomicrografias revelaram que as embocaduras dos canais laterais artificiais, independentemente dos terços analisados, em alguns casos, foram obliteradas com "smear layer" e não por dentina derretida, e que em alguns casos, o laser foi capaz de derreter dentina e selar os túbulos dentinários.
This study aimed at evaluating the influence of EDTA, Nd:YAG laser and the combination of both on the surface of the dentinal walls and for filling of artificial lateral root canals. Fifty-four single-rooted mandibular premolars with one canal were employed. Their crowns were removed and three artificial lateral root canals were prepared, one at each third of one proximal aspect of each root, by means of a reamer with a similar diameter to a K file #15. After preparation of the lateral canals, the main canals were instrumented with K files up to #40 at the apical portion and Gates Glidden burs at the middle and cervical thirds. Irrigation was performed with 1% sodium hypochloride every change of instrument, followed by final irrigation with saline solution. The teeth were divided in three groups with 18 roots each, according to the type of treatment applied to the canal walls: Group 1 - application of EDTA for 5 minutes, agitation with the working length file, and final irrigation with saline solution; Group 2 - four applications of Nd:YAG laser at 15 Hz, 100 mJ and 1.5 Watts with helicoidal movement in each tooth; and Group 3 - application of EDTA as described for group 1, finalizing with application of Nd:YAG laser as described for Group 2. Three roots were prepared for SEM analysis and the remaining 15 roots were obturated. Obturation was carried out with AH plus cement through Tagger's hybrid technique. Radiographs of the roots were then obtained in order to analyze the obturation of the artificial lateral canals. The roots employed for SEM analysis were longitudinally sectioned and prepared for the photomicrographs, in which an attempt was made to demonstrate the openings of the lateral canals and dentinal tubules. No statistically significant differences (p < 0.05) were observed between the performed procedures, neither for the independent analysis of each third regarding obturation of the artificial lateral canals. The photomicrographs revealed that the openings of the artificial lateral canals were obliterated by "smear layer" in some instances, and not by the dissolved dentin. Besides, in some cases the application of laser was unable to dissolve the dentin and seal the dentinal tubules.
APA, Harvard, Vancouver, ISO, and other styles
48

Carvalho, Cláudio Antonio Talge. "Avaliação in vitro da resistência estrutural em dentes fragilizados utilizando reforços intra-radiculares /." São José dos Campos, 2002. http://hdl.handle.net/11449/114073.

Full text
Abstract:
Orientador: Marcia Carneiro Valera
Banca: Silvia Lustosa de Castro
Banca: Maria Antonia Pereira
Banca: Alberto Siqueira e Silva
Banca: Ana Paula Martins Gomes
Resumo: Dentes com rizogênese incompleta quando sofrem trauma com conseqüente necrose pulpar permanecem com suas paredes dentinárias finas e fragilizadas, tornando-se mais suscetiveis a reincidências de fraturas. A proposta deste trabalho foi avaliar através do teste de compressão a resistência à fratura de dentes bovinos fragilizados que receberam reforços intra-radiculares com resina composta ou pino de fibra de zircônia. Para tanto, utilizou-se 56 dentes bovinos, os quais tiveram suas coroas seccionadas padronizando o tamanho das raízes em 30mm. Os dentes foram divididos em quatro grupos experimentais (14 dentes} e, com exceção do grupo 04 (Controle negativo), todos os canais radiculares foram preparados biomecanicamente até o instrumento de nº 80 e alargados com brocas Gates-Glidden nos 3, 4, 5 e 6 até 20mm de profundidade. A porção coronária foi alargada com broca diamantada tronco cônica nº 721 até a junção cemento-esmalte vestibular e, com broca diamantada tronco cônica nº 716, realizou-se a fragilização das paredes dentinárias do canal radicular a 20mm de profundidade, deixando aproximadamente 2mm de espessura em cada parede. Após, as raízes foram divididas em grupos: grupo 01-receberam reforço intra-radicular com resina composta, fotopolimerizada com o auxílio do sistema Luminex , seguida da obturação do canal; grupo 02-obturação do canal deixando os 10mm apicais com material obturador, e reforço intra-radicular com pino de fibra de zircõnia cimentado com cimento resinoso; o grupo 03-(Controle positivo) não recebeu reforço intra-radicular e foi obturado pela técnica da condensação lateral ativa; no grupo 04-(Controle negativo), os dentes não foram fragilizados. Os espécimes foram embutidos em blocos metálicos, os quais foram adaptados a um dispositivo cilíndrico, de modo que os espécimes foram fixados a 45°. Este dispositivo foi adaptado a um...
Abstract: lmmature teeth when suffer trauma with consequent necrosis pulpar they stay with its dentinal walls thin and brittle, becoming more susceptible to the second injuries. The purpose of this work is to evaluate through the compression test, the resistance to fracture of teeth bovine brittleness that received reinforcements within the root canal with composite resin or pins of zircônia fiber. lt was used 56 bovine teeth, which had its crowns sectioned in the medium third standardizing the size of the specimens in 30mm of length. The teeth were divided in four experimental groups (14 teeth) and, except for the group 04 (negative control), all the root canal was instrumented to #80 and enlarged firstly with drills Gates-Glidden numbers 3, 4, 5 and 6 to 20mm of depth, after, lhe coronary portion was enlarged with the conical drill number 721 until the cementoenamel junction facial and, with lhe conical drill number 716, the brittleness of the dentinal walls of the root canal at 20mm of depth, leaving 2mm of thickness approximately in each wall. After, the specimens of the group 01 received reinforcement within the root canal with composite resin, that was cured by aid of the Luminex system and, after, they were obturated; in lhe group 02, the specimens were obturated. Just leaving the 10mm apical with material, and they received reinforcement within the root canal with zircônia fiber pins cemented with resinous cement; the group 03 (positive control) it didn't received reinforcement within the root canal and it was obturated by the technique of the active lateral condensation; in the group 04 (negative control), the teeth were not brittleness. After, all the specimens were embedded with acrylic resin chemically activated, in metallic blocks, which were adapted to a cylindrical device, so that the specimens were fractured by load in angle of 45°. This device was adapted to a lnstron machine, ...
Doutor
APA, Harvard, Vancouver, ISO, and other styles
49

Nagayassu, Marcos Paulo. "Efeito dos tratamentos de superfície na resistência da união porcelana/cimento resinoso /." São José dos Campos, 2003. http://hdl.handle.net/11449/113974.

Full text
Abstract:
Orientador: José de Eduardo Junho de Araújo
Banca: Paulo Sérgio Mutarelli
Banca: Lafayette Nogueira Junior
Resumo: O objetivo deste estudo in vitro foi avaliar o efeito de diferentes tratamentos da superfície cerâmica, na resistência ao cisalhamento da união entre porcelana e cimento resinoso. Foram confeccionados sessenta pares de discos de porcelana aluminizada a 50% Vitadur Alpha (Vita), de tamanhos padronizados em 6mm de diâmetro por 3mm de espessura (A), e 3mm por 3mm (B). As amostras foram divididas aleatoriamente em seis grupos (n=10), de acordo com um dos seguintes tratamentos de superfície: condicionamento com ácido fluorídrico por 2 e 4min (G1 e G2), jateamento com óxido de alumínio (50µm) por 5s (G3), jateamento seguido de ácido fluorídrico por 2 e 4min (G4 e G5) e controle (G6). Em seguida, foi aplicado silano (Tokuso Ceramic Primer - Tokuyama) na superfície tratada de ambos os discos, e os discos B foram cimentados sobre os respectivos discos A, utilizando cimento resinoso dual (Bistite ll DC- Tokuyama). Os espécimes foram armazenados em água destilada a 37ºC por 24h, para posterior teste de cisalhamento em máquina de ensaio universal. Os resultados obtidos, expressos em MPa, foram submetidos aos testes de ANOVA fator único e Tukey (p≤0,05). O condicionamento com ácido fluorídrico por 2min apresentou resultados significantemente superiores ao condicionamento por 4min e ao grupo controle, porém não diferiu estatisticamente do jateamento, associado ou não ao ácido fluorídrico por 2 ou 4min
Abstract: The aim of this ln vitro study was to evaluate the effect of different surface treatments on the shear bond strength between porcelain and resin cement. Sixty pairs of 50% aluminous porcelain (Vitadur Alpha - Vita) discs were fabricated, each with 6mm in diameter by 3mm in thickness (A), and 3 by 3mm (B). Samples were randomly divided into six groups (n=10), according to one of the following surface treatments: etching with 10% hydrofluoric acid for 2 or 4min (G1 and G2); sandblasting with aluminum oxide (50µm) for 5s (G3); sandblasting followed by etching for 2 or 4min (G4 e G5) and control (G6). Then, silane was applied (Tokuso Ceramic Primer- Tokuyama) on the treated surface of both discs, and using a dual-cure resin cement (Bistite ll DC- Tokuyama), B discs were bonded together with their respective A discs. Specimens were stored in distilled water at 37ºC for 24h before shear bond strength were determined on a universal testing machine. The results, in MPa, were compared by one-way ANOVA and Tukey test (p≤0,05). Bond strength produced alter etching with 10% hydrofluoric acid for 2min was significantly higher than etching for 4min and control, but there was no statistical difference to sandblasting a/one, or followed by etching for 2 or 4min
Mestre
APA, Harvard, Vancouver, ISO, and other styles
50

Naressi, Suely Carvalho Mutti. "Estudo comparativo de resistência ao cisalhamento em reconstruções com amálgama, utilizando como procedimento retentivo pino rosqueável, amalgapin e adesivo dentário /." São José dos Campos, 1995. http://hdl.handle.net/11449/113958.

Full text
Abstract:
Orientador: José Benedicto de Mello
Banca: Dan Mihail Fichman
Banca: Maria Amélia Maximo de Araujo
Resumo: Objetivando evitar perda de dentes posteriores com grandes destruições coronárias, este trabalho comparou, mediante termociclagem e testes laboratoriais, a resistência ao cisalhamento entre três procedimentos retentivos de reconstrução com amálgama em dentes pré-molares com preparo tipo flat: pino rosqueável, amalgapin e amálgama adesivo. Os valores resultantes da ação das forças e a análise das falhas, visualmente e em microscopia ótica estereoscópica, permitiram inferir que o melhor procedimento retentivo ocorreu com pino rosqueável, seguido do amalgapin. A técnica do amálgama adesivo, com o material por nós utilizado, apresentou-se ineficaz como único procedimento retentivo neste tipo de reconstrução
Abstract: In order to avoid the loss of largely destroyed crowns of posterior teeth, this study dealt with laboratory tests to compare the resistance to shear strengths application among three retentive procedures for amalgam buildups: adhesive amalgam, amalgapin and threadned pin. The failures resultant from the strength action, analysed visually and stereoscopic otic microscopy, permitted to conclude that the best retentive procedure happened with threadned pin, followed by amalgapin. The adhesive amalgam restoration technique was considered non-efficient, for the adhesive used, as the only retentive procedure in this kind of buildup
Mestre
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography