Journal articles on the topic 'Low-Dose biplanar X-Rays'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 24 journal articles for your research on the topic 'Low-Dose biplanar X-Rays.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.
Courvoisier, Aurélien, Antonio Cebrian, Julien Simon, Pascal Désauté, Benjamin Aubert, Célia Amabile, and Lucie Thiébaut. "Virtual Scoliosis Surgery Using a 3D-Printed Model Based on Biplanar Radiographs." Bioengineering 9, no. 9 (September 14, 2022): 469. http://dx.doi.org/10.3390/bioengineering9090469.
Gajny, Laurent, Shahin Ebrahimi, Claudio Vergari, Elsa Angelini, and Wafa Skalli. "Quasi-automatic 3D reconstruction of the full spine from low-dose biplanar X-rays based on statistical inferences and image analysis." European Spine Journal 28, no. 4 (October 31, 2018): 658–64. http://dx.doi.org/10.1007/s00586-018-5807-6.
Andellini, Martina, Francesco Faggiano, Roxana di Mauro, Pietro Derrico, and Matteo Ritrovato. "OP45 HTA Of A Pediatric Biplanar Low-Dose X-Ray Imaging System." International Journal of Technology Assessment in Health Care 34, S1 (2018): 17–18. http://dx.doi.org/10.1017/s0266462318000983.
Goodbody, Christine, Paz Kedem, Michaela Thompson, Huong T. Do, Douglas N. Mintz, Roger F. Widmann, and Emily R. Dodwell. "Reliability and Reproducibility of Subject Positioning with EOS Low-Dose Biplanar X-ray." HSS Journal ® 13, no. 3 (March 1, 2017): 263–66. http://dx.doi.org/10.1007/s11420-017-9548-6.
Hurry, Jennifer K., Alan J. Spurway, Elise K. Laende, Saad Rehan, Janie L. Astephen Wilson, Michael J. Dunbar, and Ron El-Hawary. "A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty." Acta Orthopaedica 94 (November 30, 2023): 555–59. http://dx.doi.org/10.2340/17453674.2023.19669.
Berg, Britt-Isabelle, Aurélien Laville, Delphine S. Courvoisier, Philippe Rouch, and Thomas Schouman. "Experiences with a new biplanar low-dose X-ray device for imaging the facial skeleton: A feasibility study." PLOS ONE 15, no. 7 (July 2, 2020): e0235032. http://dx.doi.org/10.1371/journal.pone.0235032.
Ben-Sira, Liat, Shelly I. Shiran, Li-tal Pratt, Ronit Precel, Dror Ovadia, Shlomi Constantini, and Jonathan Roth. "Use of EOS Low-Dose Biplanar X-Ray for Shunt Series in Children with Hydrocephalus: A Preliminary Study." World Neurosurgery 116 (August 2018): e273-e277. http://dx.doi.org/10.1016/j.wneu.2018.04.187.
Gheno, Ramon, Eric Nectoux, Bernard Herbaux, Matteo Baldisserotto, Luiz Glock, Anne Cotten, and Nathalie Boutry. "Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device." European Radiology 22, no. 4 (October 20, 2011): 765–71. http://dx.doi.org/10.1007/s00330-011-2308-y.
Hosseinian, S., and H. Arefi. "3D RECONSTRUCTION FROM MULTI-VIEW MEDICAL X-RAY IMAGES – REVIEW AND EVALUATION OF EXISTING METHODS." ISPRS - International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences XL-1-W5 (December 11, 2015): 319–26. http://dx.doi.org/10.5194/isprsarchives-xl-1-w5-319-2015.
Hosseinian, S., and H. Arefi. "PHOTOGRAMMETRY IN 3D MODELLING OF HUMAN BONE STRUCTURES FROM RADIOGRAPHS." ISPRS - International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences XLII-2/W4 (May 10, 2017): 115–21. http://dx.doi.org/10.5194/isprs-archives-xlii-2-w4-115-2017.
Kerbrat, Adeline, Isabelle Rivals, Pauline Dupuy, Gauthier Dot, Britt-Isabelle Berg, Valérie Attali, and Thomas Schouman. "Biplanar Low-Dose Radiograph Is Suitable for Cephalometric Analysis in Patients Requiring 3D Evaluation of the Whole Skeleton." Journal of Clinical Medicine 10, no. 23 (November 23, 2021): 5477. http://dx.doi.org/10.3390/jcm10235477.
Thépaut, Matthias, Sylvain Brochard, Julien Leboucher, Mathieu Lempereur, Eric Stindel, Valentin Tissot, and Bhushan S. Borotikar. "Measuring physiological and pathological femoral anteversion using a biplanar low-dose X-ray system: validity, reliability, and discriminative ability in cerebral palsy." Skeletal Radiology 45, no. 2 (November 27, 2015): 243–50. http://dx.doi.org/10.1007/s00256-015-2298-y.
Assi, A., A. Presedo, A. Baudoin, D. Mitton, I. Ghanem, and W. Skalli. "Specific 3D reconstruction for children lower limbs using a low dose biplanar X-ray system. Reproducibility of clinical parameters for cerebral palsy patients." Computer Methods in Biomechanics and Biomedical Engineering 10, sup1 (January 2007): 27–28. http://dx.doi.org/10.1080/10255840701479065.
Dietrich, Tobias J., Christian W. A. Pfirrmann, Alexander Schwab, Katja Pankalla, and Florian M. Buck. "Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography." Skeletal Radiology 42, no. 7 (March 28, 2013): 959–67. http://dx.doi.org/10.1007/s00256-013-1600-0.
Koutras, Christos, Hamed Shayestehpour, Jesús Pérez, Christian Wong, John Rasmussen, Maxime Tournier, Matthieu Nesme, and Miguel A. Otaduy. "Biomechanical Morphing for Personalized Fitting of Scoliotic Torso Skeleton Models." Frontiers in Bioengineering and Biotechnology 10 (July 19, 2022). http://dx.doi.org/10.3389/fbioe.2022.945461.
Kümmerlin, Jana, Hannah Katharina Fabro, Peter Heide Pedersen, Kenneth Krogh Jensen, Dennis Pedersen, and Michael Skipper Andersen. "Measuring Knee Joint Laxity in Three Degrees-of-Freedom In Vivo Using a Robotics- and Image-Based Technology." Journal of Biomechanical Engineering 144, no. 8 (March 4, 2022). http://dx.doi.org/10.1115/1.4053792.
Mekhael, Elio, Rami El Rachkidi, Renee Maria Saliby, Nabil Nassim, Karl Semaan, Abir Massaad, Mohamad Karam, et al. "Functional assessment using 3D movement analysis can better predict health-related quality of life outcomes in patients with adult spinal deformity: a machine learning approach." Frontiers in Surgery 10 (May 3, 2023). http://dx.doi.org/10.3389/fsurg.2023.1166734.
Hultenmo, Maria, Anders Nygren, Björn Söderberg, and Håkan Wåhlander. "Dose Evaluation and Proposal of Local Diagnostic Reference Levels for Paediatric Cardiac Catheterizations Performed on a High-Sensitivity Angiographic System Allowing Low-Dose Imaging." Radiation Protection Dosimetry, June 9, 2021. http://dx.doi.org/10.1093/rpd/ncab072.
Park, Jun Young, Byung Woo Cho, Hyuck Min Kwon, Kwan Kyu Park, and Woo-Suk Lee. "Knee Extension Is Related to the Posteriorly Deviated Gravity Line to the Pelvis in Young Adults: Radiographic Analysis Using Low-Dose Biplanar X-ray." Yonsei Medical Journal 63 (2022). http://dx.doi.org/10.3349/ymj.2022.0184.
Gennari, A., T. Langlais, S. Litrico, S. Persohn, J. Allain, and W. Skalli. "Biomechanical specimen assessment by low dose biplanar X-ray study of fusion constructions using a posterior lumbar cage with integrated anchors and posterior adjunctive fixators." Computer Methods in Biomechanics and Biomedical Engineering, August 16, 2021, 1–7. http://dx.doi.org/10.1080/10255842.2021.1966625.
Deng, Min, Qianyun Chen, Qiao Deng, Lin Shi, Cherry Cheuk Nam Cheng, Kwong Hang Yeung, Rongli Zhang, et al. "Statistical changes of lung morphology in patients with adolescent idiopathic scoliosis after spinal fusion surgery—a prospective nonrandomized study based on low-dose biplanar X-ray imaging." Quantitative Imaging in Medicine and Surgery, January 2021, 0. http://dx.doi.org/10.21037/qims-21-1147.
Peeters, C. M. M., G. J. F. J. Bos, D. H. R. Kempen, P. C. Jutte, C. Faber, and F. H. Wapstra. "Assessment of spine length in scoliosis patients using EOS imaging: a validity and reliability study." European Spine Journal, October 15, 2022. http://dx.doi.org/10.1007/s00586-022-07326-4.
Peeters, C. M. M., L. van Houten, D. H. R. Kempen, F. H. Wapstra, P. C. Jutte, I. van den Akker-Scheek, and C. Faber. "Assessment of pedicle size in patients with scoliosis using EOS 2D imaging: a validity and reliability study." European Spine Journal, April 25, 2021. http://dx.doi.org/10.1007/s00586-021-06839-8.
Shakeri, Mohammadreza, Seyed Mani Mahdavi, Masih Rikhtehgar, Mohammad Soleimani, Hasan Ghandhari, Behnam Jafari, and Seyedehsan Daneshmand. "EOS® is reliable to evaluate spinopelvic parameters: a validation study." BMC Medical Imaging 24, no. 1 (February 6, 2024). http://dx.doi.org/10.1186/s12880-023-01178-0.