Dissertations / Theses on the topic 'IMRT'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'IMRT.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Sheta, Amal. "IMRT and Rotational IMRT (mARC) Using Flat and Unflat Photon Beams." Doctoral thesis, Universitätsbibliothek Leipzig, 2016. http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-208212.
Full textKhadija, Murshed. "A Comparative Analysis of Conventional MLC Based IMRT and Solid Compensator Based IMRT Treatment Techniques." University of Toledo Health Science Campus / OhioLINK, 2009. http://rave.ohiolink.edu/etdc/view?acc_num=mco1264434257.
Full textSchiefer, Hans. "Kontrollen des Planungs-Bestrahlungsprozesses bei IMRT /." Basel : [s.n.], 2009. http://edoc.unibas.ch/diss/DissB_8781.
Full textMatsushima, Luciana Cardoso. "Determinação das curvas de isodose e confirmação do planejamento em Radioterapia de Intensidade Modulada - IMRT convencional empregando as técnicas de termoluminescência, luminescência opticamente estimulada e detectores semicondutores." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-24042015-095037/.
Full textRadiotherapy is one of three principal treatment modalities used in the treatment of malignant diseases such as cancer; the other two are chemotherapy and radiosurgery. In contrast to other medical specialties that rely mainly on the clinical knowledge and experience of medical specialists, radiotherapy, with its use of ionizing radiation in treatment of cancer, relies heavily on modern technology and the collaborative efforts of several professionals whose coordinated team approach greatly influences the outcome of the treatment. Intensity modulated radiation therapy (IMRT) with the use of multileaf collimators (MLCs) has the potential to achieve a much higher degree of target conformity and normal tissue sparing than most other treatment techniques, especially for target volumes or organs at risk with complex shapes. However, recent studies show that low doses of radiation can cause secondary cancers. This work aims to determine the radiation dose distribution in several radiation therapy treatment simulations with use of LiF:Mg,Ti; CaSO4:Dy and Al2O3:C dosimeters using a PMMA phantom for the following dosimetry techniques: thermoluminescence, optically stimulated luminescence (OSL) and semiconductor detectors.
Barros, Catarina da Silva. "Estudo, avaliação e optimização em radioterapia - IMRT." Master's thesis, Faculdade de Ciências e Tecnologia, 2010. http://hdl.handle.net/10362/4797.
Full textO cancro continua ser um problema de saúde pública, apesar dos esforços e desenvolvimentos verificados na luta contra o mesmo. Estima-se que em 2030 a incidência do cancro na população mundial duplique, sendo o envelhecimento da população a principal causa apontada pela Organização Mundial de Saúde (WHO, do inglês World Health Organization Desta forma, os avanços tecnológicos na saúde têm sido constantes, trazendo desenvolvimentos essenciais no diagnóstico e tratamento das mais variadas patologias. No que concerne à radioterapia, especialidade terapêutica utilizada em cerca de 50% a 60% dos doentes oncológicos, o seu estado acompanha os panoramas mais vanguardistas. ). A radioterapia de intensidade modelada (IMRT, do inglês Intensity-Modulated Radiation Therapy), resultante da evolução da técnica de radioterapia conformacional tridimensional (3D-CRT, do inglês Three-Dimensional Conformal Radiotherapy), veio a acrescentar à conformação geométrica do feixe de radiação, a capacidade de utilização da modulação da intensidade do mesmo. Desta forma a IMRT permite uma conformação dosimétrica, que salvaguarda ao máximo a integridade das estruturas adjacentes, bem como, o escalonamento de dose, mais eficaz do ponto de vista de controlo tumoral. No entanto, este ganho em saúde faz-se acompanhar, muitas vezes, do aumento de custos. Neste contexto é essencial avaliar e quantificar os custos, e as respectivas consequências/benefícios clínicos inerentes à utilização da tecnologia. Com este projecto, realizado em contexto empresarial, pretendeu-se estudar, avaliar e elaborar propostas de optimização que visem a implementação clínica da IMRT, aplicada a patologias da próstata e mama, num Serviço de Radioterapia de um Prestador de Cuidados de Saúde (PCS) público. Neste prestador, foram analisados todos os procedimentos do workflow de 3D-CRT das patologias da cabeça e pescoço (C&P), mama e da próstata, incluindo a caracterização a nível dos recursos humanos (RH) com a respectiva duração característica de cada tarefa mapeada, quer dos recursos tecnológicos envolvidos. Visto este PCS já ter iniciado a aplicação clínica de IMRT ao cancro de C&P, foram também analisados os procedimentos referentes a esta patologia, de forma a servirem de base para a realização dos modelos de IMRT para a mama e próstata, tal como, para comparar os custos inerentes à realização desta técnica, em relação à técnica conformacional. Por último projectou-se cenários da realização IMRT ao invés da 3D-CRT no PCS em estudo, para a neoplasia que economicamente se mostrou mais favorável.
Garcia, Aaron Nicholas. "Comparative Investigation of Dosimetric Tools in IMRT." Wright State University / OhioLINK, 2007. http://rave.ohiolink.edu/etdc/view?acc_num=wright1187369612.
Full textCruz, António Manuel Costa. "IMRT beam angle optimization using Tabu search." Master's thesis, Universidade de Aveiro, 2014. http://hdl.handle.net/10773/17714.
Full textO número de pacientes com cancro continua a crescer no mundo e a Organização Mundial da Saúde considerou mesmo esta como uma das principais ameaças para a saúde e o desenvolvimento humano. Dependendo da localização e das especi cidades do tumor, existem muitos tratamentos que podem ser usados, incluindo cirurgia, quimioterapia, imunoterapia e radioterapia. A Radioterapia de Intensidade Modulada (IMRT | Intensity Modulated Radiation Therapy) é uma das modalidades mais avançadas de radioterapia, onde a otimização pode ter um papel importante no que diz respeito à qualidade do tratamento aplicado. Em IMRT, o feixe de radiação pode ser visto como se fosse constituído por vários pequenos feixes, pelo uso de um colimador multifolhas, que permite que a intensidade seja modulada. Este complexo problema de otimização pode ser dividido em três subproblemas, que estão relacionados entre si e que podem ser resolvidos sequencialmente. Para cada paciente, os ângulos de onde a radiação ir a ocorrer têm de ser determinados (problema geométrico | otimização angular). Depois, para cada um desses ângulos, o mapa de intensidades (ou fluências) tem de ser calculado (problema das intensidades | otimização das fluências). Finalmente, e necessário determinar o comportamento do colimador multifolhas, de forma a garantir que as intensidades são, de facto, atribuídas (problema de realiza ção). Em cada um destes problemas de otimização, a qualidade do tratamento atribuído depende dos modelos e algoritmos usados. Neste trabalho, a nossa atenção estará particularmente focada na otimização angular, um problema conhecido por ser altamente não-convexo, com muitos mínimos locais e com uma função objetivo que requer muito tempo de computação para ser calculada. Tal significa, respetivamente, que os algoritmos que sejam baseados no cálculo de gradientes ou que requeiram muitas avaliações da função objetivo podem não ser adequados. Assim, os procedimentos metaheurísticos podem ser uma boa alternativa para abordar este problema, visto que são capazes de escapar de mínimos locais e são conhecidos por conseguirem calcular boas soluções em problemas complexos. Neste trabalho ser a descrita uma aplicação para Pesquisa Tabu. Serão ainda apresentados os testes computacionais realizados, considerando dez casos clínicos de pacientes previamente tratados por radioterapia, pretendendo-se mostrar que a Pesquisa Tabu e capaz de melhorar os resultados obtidos através da solução equidistante, cujo uso e comum na prática clínica.
The number of cancer patients continues to grow worldwide and the World Health Organization has even considered cancer as one of the main threats to human health and development. Depending on the location and speci cities of the tumor, there are many treatments that can be used, including surgery, chemotherapy, immunotherapy and radiation therapy. Intensity Modulated Radiation Therapy (IMRT) is one of the most advanced radiation therapy modalities, and optimization can have a key role in the quality of the treatment delivered. In IMRT, the radiation beam can be thought of as being composed by several small beams, through the use of a multileaf collimator, allowing radiation intensity to be modulated. This complex optimization problem can be divided in three related subproblems that can be solved sequentially. For each patient, the angles from which the radiation will be delivered have to be determined (geometric problem | beam angle optimization). Then, for each of these angles, the radiation intensity map is calculated ( uence or intensity optimization). Finally, it is necessary to determine the behavior of the multileaf collimator that guarantees that the desired radiation intensities are, indeed, delivered (realization problem). In each of these optimization problems, the quality of the treatment delivered depends on the models and algorithms used. In this work the attention will be focused in beam angle optimization, a problem known to be highly non{convex, with many local minima and with an objective function that is time expensive to calculate, which, respectively, means that algorithms that are gradient{based or that require many objective function evaluations will not be adequate. Metaheuristics can be the right tool to tackle this problem, since they are capable of escaping local minima and are known to be able to calculate good solutions for complex problems. In this work, an application of Tabu Search to beam angle optimization is described. Computational results considering ten clinical cases of head{and{neck cancer patients are presented, showing that Tabu Search is capable of improving the equidistant solution usually used in clinical practice.
Markovic, Miljenko. "Comparison of IMRT delivery methods a thesis /." San Antonio : UTHSC, 2008. http://learningobjects.library.uthscsa.edu/cdm4/item_viewer.php?CISOROOT=/theses&CISOPTR=58&CISOBOX=1&REC=13.
Full textHeeger, Jonas [Verfasser]. "Bestrahlung von Kopf-Hals-Tumoren mit fluenzmodulierter Radiotherapie (IMRT) : Vergleich zweier IMRT-Techniken mit 3D-konformaler Bestrahlung / Jonas Heeger." Köln : Deutsche Zentralbibliothek für Medizin, 2013. http://d-nb.info/1042333823/34.
Full textFlosi, Adriana Aparecida. "Desenvolvimento de cálculo de unidades monitoras para IMRT." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-03042012-092734/.
Full textIndependent verification of dose calculations and monitor units settings of IMRT treatment plans is an important step in the quality assurance procedure for IMRT technique. At present, the verification is mainly based on experimental measurements, which are time consuming and laborious. In this work an independent methodology of monitor units calculation was developed as a new tool for IMRT treatments quality and precision assurance. The values found are near those calculated by the treatment planning system used, in a manner that the calculation algorithm demonstrated ± 1,8 % concordance in a simple geometry with the system. After several tests and the levels of action well established, the independent monitor units verification for IMRT treatment plans will become an effective and efficient tool in quality assurance, helping identification and the reduction of possible mistakes in radiotherapy treatments. To radiotherapy services is assured the use of the developed methodology as a tool of quality control in IMRT treatments as an original contribution of this work, specially those that do not dispose financial resources to acquire commercially available independent monitor unit calculus software.
FLOSI, ADRIANA A. "Desenvolvimento de cálculos de unidades monitoras para IMRT." reponame:Repositório Institucional do IPEN, 2011. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10087.
Full textMade available in DSpace on 2014-10-09T14:00:37Z (GMT). No. of bitstreams: 0
Dissertação (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
Borges, Leandro Federiche. "Validação da metodologia de controle da qualidade in vivo com auxílio de filme radiocrômico, aplicados à teleterapia." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/17/17159/tde-04012017-155803/.
Full textThe measurement of dose, using the in vivo technique dosimetry, ensures that the dose calculated by the planning system is exactly the same as the dose delivered in linear accelerator, this ensures quality assurance in radiotherapy. The objective of this study was to evaluate the quality control techinique of IMRT treatments using radiochromic film. We analyzed 47 IMRT plans, which divided into three regions: Prostate, head and neck, and skull. For each plan, we used a radiochromic film coupled in linear accelerator head by a tray prepared to film placement. The film was stored for 24 hours after irradiation. Reading and analysis of point dose and 2D dose distribution were performed after this period. ll plans analyzed, the approval rating was 92%, and the others were flunked at least one criterion. Based on the results obtained in vivo dosimetry with radiochromic film was validated. This technique is reliable and practical to measure the dose delivered by linear accelerator.
Haukås, Solveig. ""Optimalisering av IMRT-planar for øyre-nase-hals-kreft"." Thesis, Norwegian University of Science and Technology, Department of Physics, 2009. http://urn.kb.se/resolve?urn=urn:nbn:no:ntnu:diva-6259.
Full textIn the dose planning system Oncentra MasterPlan there is a module for IMRT planning (IMRT - Intensity modulated radiation therapy). This module optimizes the plan based on given requirements for doses given to target volumes and organs at risk. The new enhanced algorithm (PBE), which is implemented in MasterPlan, is supposed to make the IMRT planning more exact and effcient. A cylindrical shaped target volume, with an organ at risk inside, was defined in MasterPlan to evaluate the dose distribution modeled by the PBE algorithm. A uniform dose of 2 Gy for the target volume and a maximum dose of 0.5 Gy for the organ at risk were set for the optimization. The plans were optimized with different angles of the collimator system, and film measurements were done according to the plans. It was found that the PBE algorithm gives a good description of the dose distribution, “tongue and groove" included, for IMRT optimization.
The principle of IMRT is to treat the patient with non-uniform beams from different directions around the patient. The beams are being optimized to give a high dose to the target volume and an acceptable low dose to the normal tissue and the organs at risk. An !IMRT value" is given as a measure of the quality of the optimization in MasterPlan. This value is used to compare treatment plans, to evaluate the quality of the optimization for different parameters.
The parameters which were examined were the angle of the collimator system, the number of beams given, number of segments, minimum number of MU per segment and minimum field size per segment. It was of interest to see how the parameters affect the IMRT optimization in MasterPlan. 11 patient plans were therefore replanned by varying these parameters. The “IMRT values" for the optimized plans were compared with the one-way ANOVA test Tukey HSD.
No significant differences were shown between the “IMRT values" of the plans with different angles of the collimator system. Nor were any significant differences shown between plans with 5, 7 or 9 beams equally spaced around the patient. Treatment plans containing beams equally spaced were significantly better than plans containing beams given only in front of the patient. The treatment plans containing 30 segments were significantly worse than the plans containing 50, 70 or 150 segments, according to the Tukey test. Although there was no porvable significant difference between the “IMRT values" for 50 and 70 segments, all the tested patients had a lower value (indicating better optimization) for plans containing 70 segments. The improvement of the optimization of plans with more than 70 segments was found to be small. There was no significant difference between the optimization of plans with 2 or 4 MU.
In addition to optimize the weight and fluence of the beams, MasterPlan can also optimize the gantry angles. This has been done for plans of 5 beams and with two different set of initial angles. Gantry optimizations were performed with initial angles formed as a fan in front of the patient and with angles equally spaced around the patient. It was found that in MasterPlan, different angles are found to be optimal depending on the initial angles.
One often wants to give a small part of the target volume a higher dose than the rest of the target, in treatment of head and neck cancer. This can be done in two ways. A boost plan can be made in addition to the original plan without boost, where a small part of the target volume is given a higher dose. This involves optimization and treatment of two plans. Another way is to integrate the boost plan in the original plan, and in this way make one plan. To see if it is possible to achieve more conform dose distributions for treatment with simultaneous integrated boost (SIB) than with the additional plan, 9 of the patients were planned with both methods. It was found that SIB enables more sparing of the organs at risk. A lower dose, closer to the predefined dose criterias of the target volume outside the boost volume is also achieved.
Planleggingsprogrammet Oncentra MasterPlan har ein modul for IMRT-planlegging (IMRT - Intensity modulated radiation therapy). Denne modulen optimaliserer planar på bakgrunn av førehandsgjevne dosekrav til målvolum og risikoorgan. Den nye ”enhanced"-algoritmen (PBE) som no er implementert i MasterPlan skal gjere IMRT-planlegginga meir korrekt og effektiv. For å sjekke kor bra dosefordelingane er modellert av PBE-algoritmen vart det definert eit sylinderforma, holt målvolum med eit risikoorgan inni. Det vart sett krav om uniform dose på 2 Gy for målvolumet og maks 0,5 Gy for risikoorganet. Planar vart optimalisert med omsyn til desse krava og med ulike vinklar på kollimatorsystemet. Deretter vart det bestrålt filmar i samsvar med planane, og desse vart samanlikna med dosefordelinga i planane. Det vart funne at PBE-algoritmen gjev ei svært bra beskriving av dosefordelingar med ”tongue and groove"-effektar ved IMRT-optimalisering.
Prinsippet bak IMRT er å behandle ein pasient med ikkje-uniforme felt frå ulike retningar rundt pasienten. Desse felta har blitt optimalisert for å gje høg dose til målvolumet og akseptabel låg dose til det omkringliggjande normalvevet og risikoorgana. I MasterPlan vert det oppgjeve ein IMRT-verdi som er eit mål på kor god optimaliseringa er i forhold til dei gjevne dosekrava. Denne IMRT-verdien er nytta ved samanliking av planar, for å finne ut kor god plan ein kan oppnå ved bruk av ulike parametrar under optimaliseringa.
Parametrar som vart undersøkt var vinkel på kollimatorsystemet, tal på felt, feltretning, tal på segment, minimum MU per segment og minimum feltstorleik per segment. For å sjå korleis valet av desse parametrane påverkar IMRT-optimaliseringa i MasterPlan, vart 11 pasientplanar replanlagt ved å variere parametrane. IMRTverdien til dei optimaliserte planane vart deretter samanlikna ved hjelp av one-way ANOVA-testen Tukey HSD.
Tukey-testen viste at det ikkje var nokon signifkant forskjell mellom IMRTverdiane til planane med ulike kollimatorvinklar. Det vart heller ikkje vist nokon signifkant forskjell mellom planar med 5, 7 og 9 felt jamt fordelt rundt pasienten. Planar med felt jamt fordelt rundt pasienten vart påvist å vere signifikant betre enn felt i vifteform framføre pasienten. I følgje Tukey-testen er planen med 30 segment signifikant dårlegare enn planane med 50, 70 og 150 segment. Det vart òg sett at optimaliseringa vart betre med 70 segment enn med 50 segment for alle dei testa pasientane. Ved å bruke fleire enn 70 segment vart det lita forbetring av optimaliseringa. For dei 11 pasientane vart det ikkje funne nokon signifikant forskjell for optimaliseringa av planar med 2 og 4 MU.
I tillegg til å optimalisere vektinga og intensiteten til felta, er det i MasterPlan mogleg å optimalisere gantryvinklane som felta vert gjevne frå. Dette vart forsøkt for planar med 5 felt og med to ulike sett av gjevne startvinklar. Det vart gjort gantryoptimalisering med startvinklar i vifteformasjon framføre pasienten og med startvinklar jamt fordelt rundt pasienten. Det viste seg at MasterPlan kom fram til forskjellige optimale vinklar avhengig av startvinklane.
I behandling av øyre-nase-hals-kreft er det ofte ynskjeleg å gje ein liten del av målvolumet høgare dose enn resten av volumet. Dette kan gjerast på to måatar. Ein kan lage ein boostplan i tillegg til den vanlege planen, der ein mindre del av målvolumet får høgare dose. I dette tilfellet må ein optimalisere to planar og behandle i samsvar med begge planane. Alternativt kan ein integrere boostplanen i den opphavlege planen slik at berre ein plan vert laga. For å sjå om ein kan oppnå meir konforme planar ved samstundes integrert boost (SIB) enn ved tilleggsboost, vart 9 av pasientane planlagt på begge desse måtane. Det vart funne at SIB gjev moglegheit for meir sparing av risikoorgan og at ein får jamt over ein lågare dose, som er meir i samsvar med krava, til målvolumet utanfor boostvolumet for desse planane.
Xian, Zheng. "Dose verification of a stereotactic IMRT treatment planning system." Thesis, University of British Columbia, 2010. http://hdl.handle.net/2429/23810.
Full textFraser, Danielle J. "Characterizing ionization chamber dosimetry in inverse planned IMRT fields." Thesis, McGill University, 2005. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=84031.
Full textBoudreau, Chantal. "The use of inhomogeneity corrections for inverse planned IMRT /." Thesis, McGill University, 2004. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=81268.
Full textAnderson, J. W. "The Design and Optimisation of Novel Collimators for IMRT." Thesis, Institute of Cancer Research (University Of London), 2009. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.516269.
Full textOsewski, Wojciech. "Rekonstrukcja rozkładu dawki w technikach dynamicznych : IMRT i VMAT." Doctoral thesis, Katowice : Uniwersytet Śląski, 2013. http://hdl.handle.net/20.500.12128/5389.
Full textSheta, Amal [Verfasser], Ulrich [Akademischer Betreuer] Wolf, Thomas [Akademischer Betreuer] Kuhnt, Rolf-Dieter [Gutachter] Kortmann, and Tilo [Gutachter] Wiezorek. "IMRT and Rotational IMRT (mARC) Using Flat and Unflat Photon Beams / Amal Sheta ; Gutachter: Rolf-Dieter Kortmann, Tilo Wiezorek ; Ulrich Wolf, Thomas Kuhnt." Leipzig : Universitätsbibliothek Leipzig, 2016. http://d-nb.info/1240627637/34.
Full textWatanabe, Érika Yumi. "Avaliação do dispositivo eletrônico de imagem portal \"Portal Dosimetry\" no controle de qualidade de radioterapia de intensidade modulada." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-08082011-110213/.
Full textIn this paper we present commissioning testing and evaluation of the use of Varians portal dosimetry in the quality assurance of intensity-modulated radiotherapy. The commissioning tests were performed to characterize the portal dosimetry in terms dosimetric and to assess the its possible application in radiotherapy. These tests demonstrated that portal dosimetry has all the characteristics to be used for dosimetry in radiotherapy such as linear response with dose, the independence of dose rate, reproducibility, and others. The evaluation of the use of portal dosimetry in quality control of IMRT was performed in two steps: assessing the ability of the device to detect errors deliberately introduced in simple and complex fluences. Errors of known magnitude were introduced in certain areas of fluences and was carried out quality control of these fluences with portal dosimetry and three dosimetric systems: ionization chamber, film and array of ionization chambers. The data obtained from the portal were compared with those of other devices and all were able to identify errors introduced satisfactorily, the values, normalized to the original fluence, obtained with the portal dosimetry were similar to the ionization chamber and the array of ion chambers (seven29) and differing in up to 2% of the values obtained with the films. The fluences measured with the portal dosimetry were evaluated both quantitatively and qualitatively. The index of the gamma function provided by software analysis of portal dosimetry showed no defined rules of behavior in relation to the errors introduced and for this reason the qualitative analysis has proved indispensable in cases evaluated.
Obata, Yasunori, and Hiroshi Oguchi. "Commissioning of modulator-based IMRT with XiO treatment planning system." AIP Publishing, 2009. http://hdl.handle.net/2237/20613.
Full textMassie, Michael Todd. "Respiratory-Gated IMRT Quality Assurance with Motion in Two Dimensions." Wright State University / OhioLINK, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=wright1284726606.
Full textHofmann, Tobias. "Evaluation der intensitätsmodulierten Bestrahlungstechnik für die stereotaktische Strahlentherapie im kraniellen Bereich." Master's thesis, Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2009. http://nbn-resolving.de/urn:nbn:de:bsz:14-ds-1234514545566-63458.
Full textAndræ, Nils. "Commissioning and validation of small subfields in Step-and-shoot IMRT." Thesis, Stockholm University, Medical Radiation Physics (together with KI), 2008. http://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-8316.
Full textOne of the most used irradiation techniques in modern radiation therapy is step-and-shoot IMRT. The accuracy of this technique when delivering complex dose distributions strongly depends on the size of the subfields. The aims of this study is to determine the minimum size of subfields that can be used efficiently in Step-and-Shoot IMRT, to investigate the validation process for beam delivery and treatment planning dose calculations, and to find recommendations for practical clinical implementations.
Two different detectors, a CC04 ion chamber and a SFD stereotactic diode, have been used for measuring head scatter factors in air (Sc), total output factors (Scp) and dose profiles in water for a wide range of field sizes. The measurements were compared to calculations done with a pre-release version of the Nucletron MasterPlanTM v 3.1 treatment planning system that employs a novel, high resolution fluence modelling for both its pencil beam and collapsed cone dose calculation algorithms. Collimator settings were explicitly checked using FWHM film measurements with a build-up sheet of tungsten placed close to the treatment head to reduce the influence from lateral electron transport and geometrical penumbra. An analysis of the influence and sensitivity of Scp for small fields with respect to the linear accelerator source size and shape was also made.
The measurements with the ionization chamber and the stereotactic diode showed good agreements with each other and with the treatment planning system calculations for field sizes larger than 2×2 cm2. For small field sizes, measurements with different detectors yielded different results. Calculations showed agreements with measurements with the smallest detector, provided careful field size calibration and commissioning of calculation parameters. Uncertainties in collimator settings and source characteristics were shown to yield large uncertainties in Scp for fields smaller than 2×2 cm2.
The treatment planning system was found to properly handle small subfields but results were very sensitive to uncertainties in source size, as well as calibration and reproducibility of the collimator settings. Therefore if subfields smaller than 2×2 cm2 are to be used in IMRT extra care should be taken to determine the source characteristics and to calibrate the collimators. The volume of the detectors used for validation of such small fields and the loss of charged particle equilibrium conditions also have to be taken into consideration.
Sample, Scott Alexander. "Evaluation of Beam Angle Scoring Using MCNP and Applied to IMRT." Thesis, Georgia Institute of Technology, 2007. http://hdl.handle.net/1853/14570.
Full textBragg, Christopher Mark. "Implementation of IMRT Methods including the assessment of a new calculation algorithm." Thesis, University of Sheffield, 2007. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.490192.
Full textSonier, Marcus. "IMRT treatment planning for arteriovenous malformations : patient stratification and dosimetric quality assurance." Thesis, University of British Columbia, 2013. http://hdl.handle.net/2429/43782.
Full textHo, Kean Fatt. "Optimising dose escalated intensity modulated radiotherapy (IMRT) in head and neck cancer." Thesis, University of Manchester, 2009. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.508596.
Full textLavor, Milton. "Avaliação das ferramentas de controle de qualidade para pacientes submetidos ao IMRT." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-16062011-161534/.
Full textIntensity modulated radiation therapy (IMRT) is currently been implemented in a rapidly growing number of centers in Brazil. As consequence many institutions are now facing the problem of performing a comprehensive quality control program before and during the implementation of IMRT in the clinical routine practice. The aim of this work is to evaluate and propose a methodology for quality assurance in IMRT treatments. An ionization chamber and a two-dimensional array detector were performed to assess the absolute value of the total dose of all fields in one specific point. The relative total dose distribution of all fields was measured with a radiochromic film and a two-dimensional array at one depth in a phantom. A comparison between measured and calculated dose distributions was performed using the gamma-index method, assessing the percentage of points that meet the criteria of ±3% dose difference and ±3 mm distance to agreement. As a result of 113 tested IMRT beams using ionization chamber and 81 using two-dimensional array, the proposal was to take an action level of about ± 5% compared to the treatment planning systems and measurements, for the verification of the dose in a single point at the low gradient dose region. Analysis of the two-dimensional array measurements showed that the gamma value was <1 for 97.7% of the data and for the film the gamma value was <1 for 96.6% of the data. This can be concluded that for an accurate delivery of dose in sliding-window IMRT with micro multileaf collimator, the absolute value of the total dose and the relative total dose distribution should be checked by absolute and relative dosimetry respectively.
Soh, Hwee Shin. "Quantitative metrics for assessing IMRT plan quality : comparing planning conformity and complexity." Thesis, University of Nottingham, 2018. http://eprints.nottingham.ac.uk/51364/.
Full textTzec, Quiñones Irving Ubaldo, and Cortes Jeanette Rodríguez. "Control de calidad en tratamientos de IMRT con película radiocrómica Gafchromic EBT3." Tesis de maestría, Universidad Autónoma del Estado de México, 2017. http://hdl.handle.net/20.500.11799/66163.
Full textLAVOR, MILTON. "Avaliação das ferramentas de controle de qualidade para pacientes submetidos ao IMRT." reponame:Repositório Institucional do IPEN, 2011. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9971.
Full textMade available in DSpace on 2014-10-09T14:06:31Z (GMT). No. of bitstreams: 0
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
Jadon, Rashmi. "Adaptive image-guided radiotherapy strategies for implementation of IMRT in gynaecological malignancies." Thesis, Cardiff University, 2016. http://orca.cf.ac.uk/98750/.
Full textPichler, Joseph Alan. "IMRT Plan Delivery Verification Utilizing a Spiral Phantom with Radiochromic Film Dosimetry." University of Toledo Health Science Campus / OhioLINK, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=mco1288963613.
Full textPfeiffer, Marie-Luise [Verfasser]. "Dosisvergleich von Bestrahlungsplänen bei HNO-Tumoren für IMRT-Techniken / Marie-Luise Pfeiffer." Kiel : Universitätsbibliothek Kiel, 2018. http://d-nb.info/1155165918/34.
Full textHack, Joshua. "Development and implementation of quality-assurance standards for external beam intensity modulated radiation therapy." Toledo, Ohio : University of Toledo, 2009. http://rave.ohiolink.edu/etdc/view?acc%5Fnum=mco1265034762.
Full textMorlotti, Marcelo Scolaro. "Verificação de tratamentos radioterápicos diversos com dosimetria termoluminescente." Universidade de São Paulo, 2007. http://www.teses.usp.br/teses/disponiveis/43/43134/tde-09052007-195209/.
Full textThe last decades noticed a massive improvement in radiotherapy techniques and the use of segmented beams produced by multileaf collimators. However, the dose radiation therapy planning systems (TPS) in use are characterized by the restriction of access to the calculation algorithms. The aim of this work was to compare dose values measured in an anthropomorphic phantom (Alderson Rando Phantom - ARP) to the reference dose values obtained from the TPS in real case simulations of radiotherapy treatments. Thermoluminescent dosimetry (TLD) technique was used to evaluate the doses. LiF dosimeters (TLD100) were positioned on the phantom pelvis, thorax, head and neck at homogeneous dose regions, as the Planned Target Volume (PTV), gradient dose regions, and areas far from PTV. The doses were delivered using two techniques, 3D conformal radiotherapy and Intensity Modulated Radiation Therapy (IMRT). Four TPS were used: CadPlan, ECLIPSE, Helax-TMS and KonRad. In several situations, calculation algorithms implemented in these planning systems were employed to take heterogeneities into account: two of them were correction-based algorithms (Batho and Pencil Beam) and one of them based in beam convolution-superposition (Collapsed Cone). Furthermore, a liquid water phantom was used to compare the TLD behavior to the Farmer thimble chamber (0,6 cc internal volume) results when exposed to high-energy photon beams. It was also possible to verify the quality of the PMMA supports that wer used in the calibration of the dosimeters on clinical beam, obtaining reliable results. Both the ARP pelvis and a water phantom showed similar behavior under irradiation, indicating that, in highly homogenous regions, the ARP material can be used to simulate human soft tissues under radiotherapy treatment. Inside the PTV, the dosimetry performed in the ARP, showed compatibility between measured and planned dose values, with discrepancies smaller than 2%, which are within the ICRU62 fixed limits (+7%/-5%, 2?). When the algorithms were used, a better agreement between the experimental and planned doses was achieved, but it was not possible to discriminate the Pencil Beam and Collapsed Cone algorithms. In regions with large dose gradients, the discrepancies between experimental and planned dose values are higher as the difficulties the position of the dosimeters are more critical. The measured doses, when the 3D radiotherapy technique was used, were within the ICRU62 pre-established limits whereas the IMRT technique provider more accurate values.
Al-Roumi, Moh'd. "Verification of patient position during intensity modulated radiotherapy by electronic portal imaging devices using Monte Carlo techniques." Thesis, Queensland University of Technology, 2018. https://eprints.qut.edu.au/116175/1/Moh%27d_Al-Roumi_Thesis.pdf.
Full textTsugawa, Takahiko, Masahiro Hagiwara, Hisato Nakazawa, Tatsuya Kobayashi, Yuta Shibamoto, Chisa Hashizume, and Yoshimasa Mori. "STEREOTACTIC RADIOTHERAPY FOR SPINAL INTRADURAL METASTASES DEVELOPING WITHIN OR ADJACENT TO THE PREVIOUS IRRADIATION FIELD : REPORT OF THREE CASES." Nagoya University School of Medicine, 2013. http://hdl.handle.net/2237/18476.
Full textMathayomchan, Boonyanit. "MULTIOBJECTIVE APPROACH TO MORPHOLOGICAL BASED RADIATION TREATMENT PLANNING." Case Western Reserve University School of Graduate Studies / OhioLINK, 2006. http://rave.ohiolink.edu/etdc/view?acc_num=case1131365356.
Full textStuder, Gabriela Monika. "Intensitäts-modulierte Radiotherapie (IMRT) maligner Kopf-Hals-Tumoren : Resultate bestätigen die entwickelten Konzepte /." Zürich, 2007. http://opac.nebis.ch/cgi-bin/showAbstract.pl?sys=000253372.
Full textBrodeur, Marylène. "Verification of IMRT beam delivery with a ferrous sulfate gel dosimeter and MRI." Thesis, McGill University, 2003. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=78331.
Full textThe gel dosimeter system is tested through a set of simple experiments which characterize and confirm the system as a valid QA tool for conformal and intensity modulated radiation therapy.
For this work, dynamic photon beams are created on a commercially available inverse treatment planning system and the treatment is delivered to a gel filled acrylic mold. Software has been developed to quantify dose from the QA MR images, and to register this information to the planning computed tomography (CT) scan. The software displays the measured dose on the planning CT, and calculates dose-volume histograms for the registered measured data and contoured patient structures. This work reveals good agreement between planned and measured dose distributions, with less than 5% difference in the mean doses of the contoured patient structures.
Altenstein, Georg [Verfasser], and Uwe [Akademischer Betreuer] Oelfke. "A Novel Collimator Concept for Fast Rotational IMRT / Georg Altenstein ; Betreuer: Uwe Oelfke." Heidelberg : Universitätsbibliothek Heidelberg, 2014. http://d-nb.info/1180300637/34.
Full textTang, Nin-fai Francis. "Monte Carlo dose calculations in quality assurance for IMRT of head and neck cancers." Click to view the E-thesis via HKUTO, 2008. http://sunzi.lib.hku.hk/hkuto/record/b40203797.
Full textTang, Nin-fai Francis, and 鄧年輝. "Monte Carlo dose calculations in quality assurance for IMRT of head and neck cancers." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2008. http://hub.hku.hk/bib/B40203797.
Full textLinnebach, Julian [Verfasser], and Uwe [Akademischer Betreuer] Haverkamp. "Einsatz der intensitätsmodulierten Radiotherapie (IMRT) beim mediastinalen Hodgkin-Lymphom / Julian Linnebach ; Betreuer: Uwe Haverkamp." Münster : Universitäts- und Landesbibliothek Münster, 2014. http://d-nb.info/1138280976/34.
Full textWilliams, Matthew John Physics Faculty of Science UNSW. "Investigations into static multileaf collimator based intensity modulated radiotherapy." Awarded by:University of New South Wales. Physics, 2005. http://handle.unsw.edu.au/1959.4/20577.
Full textYin, Lingshu. "Dose painting to combat tumor hypoxia while sparing urethra in prostate IMRT: a biologically based adaptive approach accounting for setup uncertainties and organ motion." Thesis, University of British Columbia, 2008. http://hdl.handle.net/2429/2524.
Full textSilva, Luis Felipe Oliveira e. "Desenvolvimento e avaliação de um sistema de cálculo de dose independente para controle de qualidade de IMRT do tipo jaws-only." reponame:Repositório Institucional da UnB, 2015. http://dx.doi.org/10.26512/2015.10.D.20724.
Full textSubmitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-06-06T17:55:07Z No. of bitstreams: 1 2015_LuisFelipeOliveiraeSilva.pdf: 5470471 bytes, checksum: 1fe65af174596febff5a94a7a05ae399 (MD5)
Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-06-15T11:30:22Z (GMT) No. of bitstreams: 1 2015_LuisFelipeOliveiraeSilva.pdf: 5470471 bytes, checksum: 1fe65af174596febff5a94a7a05ae399 (MD5)
Made available in DSpace on 2016-06-15T11:30:22Z (GMT). No. of bitstreams: 1 2015_LuisFelipeOliveiraeSilva.pdf: 5470471 bytes, checksum: 1fe65af174596febff5a94a7a05ae399 (MD5)
A radioterapia de intensidade modulada (IMRT, do inglês intensitymodulatedradiotherapy) proporciona distribuições de dose bastante complexas, com regiões de alto gradiente de dose. Essa complexidade representa um desafio maior no controle de qualidade (CQ) quando se compara a IMRT com a radioterapia convencional. O objetivo do presente trabalho foi desenvolver e avaliar um sistema de cálculo de dose independente, chamado SCI, para o controle de qualidade da IMRT do tipojawsonly. O software desenvolvido utiliza um algoritmo de cálculo de dose baseado em correções realizadas no fator de calibração do acelerador linear, por meio de fatores tabelados, derivados de medições e calculados a partir de simples modelagem. Os próprios dados gerados no comissionamento são usados para alimentar o algoritmo.Os cálculos são realizados em um plano de um fantoma retangular. Para validar o SCI, comparações entre as previsões dosimétricas do sistema e outras referências foram realizadas. Foram comparados: doses pontuais no centro de campos assimétricos medidos com câmara de ionização; perfis de campos medidos com filme radiocrômico e com câmara de ionização; distribuições planares de dose de cinco casos de câncer de próstata e cinco de cabeça e pescoço medidas com um arranjo bidimensional de câmaras de ionização e calculadas pelo sistema de planejamento de tratamento (SPT). A avaliação foi realizada utilizando diferenças percentuais de dose, a menor diferença de posição em que se encontra o mesmo valor de dose (DTA, do inglês distancetoagreement) e a avaliação gama com critérios: (i) diferença máxima de dose de 3%, DTA de 3 mm; (ii) diferença máxima de dose 5%, DTA de 3 mm; e (iii) diferença máxima de dose 5%, DTA de 5 mm. As diferenças encontradas nas comparações entre as doses obtidas no centro de campos assimétricos foram menores do que 2,5%.As diferenças nos perfis dos campos quadrados menores do que 30x30 cm2 foram menores do que 2% ou 2mm. Os campos menores, medidos com filme, apresentaram diferenças mais consideráveis (DTAs de até 5 mm foram observadas). Esse resultado já era esperado devido à maior resolução espacial do filme quando comparada à da câmara de ionização (volume sensível de 0,125 cc). As avaliações gama usando tanto as medições quanto o SPT como referência sugerem que o SCI representa a distribuição de dose real segundo o critério de 5% de diferença máxima de dose e 5 mm de DTA, uma vez que a média de pontos aprovados foi superior a 96,5% (p<0,001) em todos os casos quando esse critério foi utilizado. O sistema também apresenta um boa representação segundo o critério de 5% de diferença máxima de dose e 3 mm de DTA (média de pontos aprovados superior a 92,0%; p<0,01). As médias de pontos aprovados com esses dois critérios estão, portanto, de acordo com os valores tipicamente usados como referência por profissionais da área de radioterapia. Desta forma, o sistema desenvolvido no presente trabalho está pronto para ser utilizado para o CQ de IMRT do tipo jawsonly sem custo adicional em relação aos equipamentos já utilizados, reduzindo o fluxo de trabalho comparado a métodos mais tradicionais e sem ocupação adicional da máquina de tratamento.
Intensity modulated radiation therapy (IMRT) provides complex dose distributions with high dose gradient regions. This complexity is a major challenge for quality assurance (QA), specially when comparing IMRT with conventional radiotherapy. In this research, I propose, develop, and evaluate an independent dose calculation system for QA of jaws only IMRT (JOIMRT). The developed software uses a dose calculation algorithm based on corrections performed over the linear accelerator (linac) calibration factor. In order to perform this corrections I used tabulated factors derived from measurements and calculated from simple modeling. Also, I used the linac's commissioning data as input to the algorithm.The developed system then performs the main computations over a rectangular phantom plan. To validate the proposed system, I compared the predictions of the dosimetric system with references that are commonly used in the literature. Specifically, I compared: point doses in the center of asymmetric field measured with an ionization chamber; dose profiles measured with radiochromic film and an ionization chamber; planar dose distributions of five of prostate and five head and neck cases measured with a two-dimensional array of ionization chambers and calculated by the treatment planning system (TPS). The evaluation was performed using percentage dose differences, distance to agreement (DTA) and gamma evaluation with tree criterions: (i) maximum difference dose of 3% and 3 mm DTA, (ii) maximum difference dose of 5% and 3 mm DTA, and (iii) maximum difference dose of 5% and 5 mm DTA. The differences in the comparisons between the doses obtained in the center of asymmetric fields were smaller than 2.5%. Differences in the profiles of square fields up to 30x30 cm2 were smaller than 2% or 2 mm. Smaller fields measured with film showed more significant differences (I measured DTAs up to 5 mm). This result was expected because of the higher spatial resolution of the film, as compared to the ionization chamber that provided the measurements used as inputs to the calculation algorithm (sensitive volume of 0.125 cc). The point approval ratings using both measurements and the TPS as a reference suggest that the independent dose calculation system represents the actual dose distribution according to the criterion of 5 % maximum dose difference and 5 mm DTA, since the average was approved points above 96.5% (<0,001) in all cases when this criterion was used. The system also features a good representation according to the criterion of 5% maximal dose difference and 3 mm DTA (average of approved points above 92.0%; p <0.01). Therefore, the average of approved points obtained with those two criteria satisfies the values typically used as references by radiotherapy professionals. In this way, the system I developed is ready to be used for the JOIMRT QA with no additional cost with respect to equipment already used, reducing the workload compared to more traditional methods and without additional treatment machine occupation.
Stambaugh, Cassandra. "The Evaluation and Study of Modern Radiation Dosimetry Methods as Applied to Advanced Radiation Therapy Treatments Using Intensity Modulated Megavoltage Photon Beams." Scholar Commons, 2015. https://scholarcommons.usf.edu/etd/5587.
Full text