Dissertations / Theses on the topic 'Implants'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Implants.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Antenucci, Rosse Mary Falcón [UNESP]. "Análise das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexões e qualidade óssea: estudo pelo método dos elementos finitos tridimensionais." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/105562.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Um aspecto crítico que afeta o sucesso ou falha de um implante é a maneira pela qual as tensões são transferidas do implante ao tecido ósseo. A sobrecarga na prótese dentária pode levar a perda da osseointegração, dessa forma, é aconselhável evitar altas concentrações de tensões no osso de suporte, do ponto de vista clínico. Entretanto, o estresse mecânico pode ter consequências positivas ou negativas no tecido ósseo, fatores esses dependentes de vários fatores associados que podem ser mecânicos ou biológicos. Portanto, o propósito do presente estudo foi analisar a influência da qualidade óssea na distribuição das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexão protética, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados doze modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco com diferentes qualidades ósseas (Tipo I, II, III e IV) e a presença de um implante (4,0x10 mm) com diferente tipo de conexão (Hexágono externo, interno e cone Morse), com coroa metalo-cerâmica. Após geração de geometrias, os modelos foram importados para o programa de pré e pós processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (4 para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos...
A critical issue that affects the success or failure of an implant is the manner in which the stresses are transferred from the implant to bone tissue. The overload can lead the dental implant to loss of osseointegration, thus it is advisable to avoid high stress concentrations in bone support, according to the clinical point of view. However, mechanical stress can bring positive or negative consequences in the bone tissue and these factors depend on association with mechanical or biological factors. Therefore, the purpose of this study was to analyze the influence of bone quality on stress distribution in implant-prosthesis unit with different types of prosthetic connection, by the three-dimensional finite element method. For this, twelve three-dimensional models were made with the aid of SolidWorks 2010 and Rhinoceros 4.0, graphical modeling software, besides the InVesalius. Each model was composed of a block with different bone qualities (Type I, II, III and IV), an implant (4.0 x 10 mm) with different type of prosthetic connection (Hexagon external, internal and Morse taper) and metal ceramic crown. After generation of geometries, the models were imported into FEMAP 10.2, the pre and post-processing finite element software, where it was generated finite element meshes, boundary and loading conditions. The 200N load was applied axially and 100N obliquely on the occlusal surface of crowns. This total load was divided among the cusps (four points for the axial load and two points for the oblique load on the lingual cusps). Then, the analysis was generated in the FEMAP 10.2 and exported to the NeiNastran version 9.2 software for calculation in finite element analysis, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and... (Complete abstract click electronic access below)
Aguiar, Juliana Ribeiro Pala Jorge de [UNESP]. "Influência do tipo de conexão pilar/implante na manutenção da pré-carga de parafusos de retenção e na desadaptação vertical da coroa protética antes e após ciclagem mecânica." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/105561.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Próteses implantossuportadas estão sujeitas a diversos tipos de falhas, sendo o afrouxamento do parafuso de retenção a complicação mais frequente, devido à perda da pré-carga inicial. A perda da pré-carga pode ser influenciada por fatores como incidência de cargas oclusais impróprias, diferentes tipos de conexões do sistema implante/prótese e desajustes entre a coroa e o implante. Sendo assim, este estudo teve como objetivo avaliar a manutenção da pré-carga de parafusos de retenção de titânio e a desadaptação vertical de coroas protéticas parafusadas, antes e após a ciclagem mecânica. Para isso, três tipos de conexões implante/pilar foram utilizados: implantes de conexão interna híbrida com pilar do tipo esteticone (grupo CIE); implantes de conexão externa com pilar o tipo esteticone (grupo CEE); e implantes de conexão externa com pilar UCLA (grupo CEU). Para cada grupo, foram confeccionadas 10 coroas metálicas fundidas em liga de CoCrMo para a composição final dos corpos-de-prova. Os parafusos de retenção protéticos receberam torque de 20N.cm nos grupos CIE e CEE e 30N.cm no grupo CEU, e, após três minutos, foi mensurado o valor de destorque inicial, com o auxílio de um torquímetro analógico. Após essa avaliação inicial, as coroas receberam novamente o torque recomendado e foram submetidas ao ensaio de ciclagem mecânica, com carga oblíqua (30°) de 130N ± 10N, a 2Hz de freqüência, totalizando 1x106 ciclos. Após a ciclagem, foi mensurado o destorque final. Além disso, antes e depois da ciclagem mecânica, foi realizada a verificação da adaptação vertical das coroas por meio de um estereomicroscópio, com as coroas parafusadas a um único implante e posicionadas em uma matriz de silicone...
Implant-supported prostheses are prone to several types of fail, and the retaining screw loosening is the most frequent complication, due to the loss of its initial preload. Loss of preload may be caused by different factors such as the incidence of excessive occlusal loading, different types of implant/prosthesis connections systems and vertical misfit between crown and implant. Thus, the aim of this study was to evaluate the preload maintenance of titanium retaining screws and to measure the vertical misfit of implant-supported screwed crowns, before and after mechanical cycling. For this purpose, three types of implant/abutment systems were embedded in polyester resin: internal hybrid connection implants and Estheticone abutments (Group ICE); external connection implants with Estheticone abutments (Group ECE); and external connection implants with UCLA abutments (Group ECU). For each group, 10 metallic crowns were cast in CoCrMo alloy for the final compositions of the specimens. Retaining screws received insertion torque of 20 N.cm in groups ICE and ECE and 30N.cm in group ECU, and, after three minutes, the initial detorque was measured through an analogical torquemeter. After this initial evaluation, crowns were retightened and submitted to cyclic loading test, with an oblique loading (30°) of 130N ± 10N, at 2Hz of frequency, totalizing 1x106 cycles. After cycling, final detorque was measured. Moreover, before and after mechanical cycling, the vertical misfit of the crowns was measured through estereomicroscopy, with the crowns screwed to a single implant and positioned into a silicone matrix. The data obtained were tabulated and submitted to variance analysis, Fisher’s exact test and Pearson’s linear... (Complete abstract click electronic access below)
Moretti, Lívia Alves Corrêa. "Microtopografia de implantes de titânio com diferentes tratamentos de superfícies à microscopia eletrônica de varredura e de força atômica." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/58/58132/tde-18092012-160925/.
Full textIntroduction: Bone-implant interface quality may be influenced by surface roughness and determines how cells interact, cling to and fix to, therefore can enhance and shorten the time for osseointegration. This study aims to analyze qualitatively the topography and architecture of different dental implants surfaces, to compare and describe them. MATERIALS AND METHODS: five implants with different surface treatments were evaluated in three different areas: apical, region of threads (tops, sides and valleys) and cervical region by scanning electron microscopy (SEM) and atomic force microscopy (AFM), correlating the possible molecular and cellular initials events of osseointegration. RESULTS: the surfaces of the implants NanoTite®, SLA® and ® Xive® TG plus, in the SEM, are similar by their appearance of gaps, although they differ in surface plane; the surface of TiUnite® implants have features such as corals and/or volcanos, while the implant Exopro ® has stretch marks in form of small grooves. The average roughness (Ra) to the AFM, appeared higher in TiUnite ® implant, followed by Xive® TG plus NanoTite®, Exopro® and SLA® implants. The area analyzed in the AFM, is restricted to small points (nanometrics), and do not allow denote a panoramic view of all structures (micrometrics), not allowing a real comparison of surface roughness. CONCLUSIONS: the optimal methodology for surfaces analysis with the objective of understanding how the cells colonize and fix to dental implants should be in the micrometer scale, highlighting the SEM over AFM. The AFM seems to be most suitable for studies aiming the interaction of the implant surface with molecular-level and SEM at the cellular level. Each treatment promotes a specific surface topography whose benefits molecular, tissue, and clinical should be studied separately.
Basílio, Mariana de Almeida [UNESP]. "Efetividade de parafusos com tratamento de superfície na estabilidade de pilares em zircônia após carga cíclica." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/97312.
Full textCom o objetivo de prevenir o afrouxamento, parafusos do pilar com lubrificantes sólidos de superfície foram desenvolvidos e introduzidos no mercado. Assim, foi proposto avaliar a efetividade de parafusos de liga de titânio com e sem tratamento de superfície sobre a estabilidade de pilares em zircônia (ZrO2) após carga cíclica, bem como observar alterações estruturais por meio de microscopia eletrônica de varredura (MEV). Para isso, 20 pilares UCLA em ZrO2 foram fixados sobre implantes do tipo hexágono externo com torque de 20 Ncm e divididos em 2 grupos (n=10), conforme o parafuso do pilar: (A) pilar-implante e parafuso de liga de titânio (Ti); (B) pilar-implante e parafuso de liga de titânio com cobertura Diamond Like Carbon (DLC/Ti). O valor do torque reverso (pré-carga) foi mensurado antes e após o carregamento. O teste foi realizado de acordo com a norma ISO 14801. Cargas cíclicas (0,5 x 106; 15 Hz) entre 11 - 211 N foram aplicadas com 30º de inclinação em relação ao longo eixo dos implantes. As médias dos grupos foram calculadas e comparadas utilizando análise de variância de dois fatores e testes F (α=0,05). Os resultados mostraram que antes do carregamento a média do grupo Ti foi significativamente maior que a do grupo DLC/Ti (p=0,021). Após o carregamento ambas as médias 14 diminuíram significativamente, sem diferença significante entre elas (p=0,499). As imagens obtidas na MEV revelaram micro-fraturas na base de assentamento do pilar. Nas condições estudadas, concluiu-se que: (1) os parafusos estudados apresentaram efetividade similar com relação à manutenção da pré-carga; (2) a redução significativa no torque reverso e os danos observados na MEV indicam que o acompanhamento dos pacientes é necessário para assegurar a longevidade das restaurações de ZrO2 implanto-suportadas.
In an attempt to prevent screw-loosening problem, abutment screws with surface treatment were developed. Thus, the aim of the current study was to evaluate comparatively the effectiveness of titanium alloy coated screws and noncoated screws on the stability of ZrO2-ceramic abutments after cyclic loading, as soon as observe possible microdamaging in the structure of the components using a scanning electron microscope (SEM). For this, 20 prefabricated ZrO2-ceramic UCLA abutments were tightened to 20 Ncm on their respective external hex implants and divided equally into 2 groups (n=10), according to the type of screws used: (A) implant-abutment and noncoated titanium alloy screw (Ti); (B) implant–abutment and titanium alloy screw with Diamond Like Carbon surface coating (DLC/Ti). The reverse torque value (preload) of the abutment screw was measured before and after loading. The tests were performed according to ISO norm 14801. A cyclic loading (0,5 x 106; 15 Hz) between 11 - 211 N was applied at an angle of 30 degrees to the long axis of the implants. Group means were calculated and compared using ANOVA and F tests (α=0,05). The results showed that before cyclic loading, the mean of Ti group was significantly higher than the DLC/Ti group (p=0,021). After cyclic loading, both means decreased significantly, with no significant differences 16 between them (p=0,499). Under the studied conditions, it can be concluded that: (1) the two abutment screw types presented similar effectiveness in maintaining preload; (2) the significant decrease in reverse torque values and the microdamaging detected at SEM analysis indicate that patient follow-up is needed to ensure the integrity of the ZrO2-ceramic single-implant restorations.
Almeida, Daniel Augusto de Faria [UNESP]. "Avaliação da influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões: estudo pelo método dos elementos finitos tridimensionais." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/97362.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O comportamento biomecânico de um implante dentário osseointegrado desempenha um importante papel na sua longevidade funcional. As limitações anatômicas às vezes tornam necessário o posicionamento de implantes com angulações fora do considerado ideal para as reabilitações protéticas, havendo maior concentração de tensões e reabsorção no osso cortical ao redor do implante. Para solucionar tais situações o profissional deve lançar mão de um cuidadoso planejamento e uso de intermediários angulados, estudando qual conexão protética melhor se adapta a situação clínica. Portanto, o propósito do presente estudo foi analisar a influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados seis modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco ósseo e a presença de um implante (4,0x10 mm) com diferentes angulações (0º, 17º e 30º) e tipos de conexão (Hexágono externo e cone morse), com coroa metalo-cerâmica. Após geração das geometrias, os modelos foram importados para o programa de pré e pós-processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (quatro para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos NeiNastran versão 9.2, executada em uma estação de trabalho...
The biomechanical behavior of an osseointegrated dental implant plays an important role in the longevity. The anatomical limitations sometimes require the placement of implants with angles outside the considered ideal for prosthetic rehabilitation, with higher stress concentration and resorption in cortical bone around the implant. Thus, in some situations, the professional should planning careful the treatment and use the abutment, analyzing the prosthetic connection which best fits the clinical situation. Therefore, the purpose of this study was to analyze the influence of the implant angulation with different types of prosthetic connection on the stress distribution, by three-dimensional finite element method. Six three-dimensional models were made with the aid of the graphical modeling and SolidWorks 2010 Rhinoceros 4.0 and InVesalius.Each model was composed of a bone blockwith an implant (4.0 x 10 mm) with different angulations (0, 17 and 30) and connection types (Hexagon external and Morse taper) with metal-ceramic crown. After generation of the geometries, the models were imported into the pre-and post-processing finite element FEMAP 10.2, where we generated finite element meshes, boundary and loading conditions. The load was applied axial 200N and 100N obliquely to the occlusal surface of crowns. This total load was divided between the cusps (four for the axial load and two oblique lingual to the load). Then, the analysis was generated in and exported 10.2 FEMAP software for calculation in finite element program NeiNastran version 9.2, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and maximum principal stress. The maps for... (Complete abstract click electronic access below)
Tunes, Fábio Sanches Magalhães. "Análise microbiológica da vedação com selante industrial de microgaps nas diferentes conexões implantares: estudo in vitro." Universidade de São Paulo, 2018. http://www.teses.usp.br/teses/disponiveis/25/25146/tde-02102018-171536/.
Full textThe use of dental implants and prosthetic components have become very feasible resources to solve simple and complex cases in rehabilitation dentistry. However, the implant component junction may present problems, such as the presence of a microgap between these components parts.Therefore, several materials have been tested in an attempt to obstruct this space, with controversial results. The objective of this study was to evaluate in vitro the behavior of an anaerobic monocomponent adhesive (Loctite® 510, Henkel Ltda), high resistance and inert characteristics, in the microgap seal preventing bacterial passage from the external side to the inner side of the assembly. A total of 90 implants were used, with hexagonal external connection (n = 30), internal hexagonal connection (n = 30) and internal conical connection (n = 30) divided into Control Group (n = 45). Implants were opened in laminar flow cabinet and each unit received 3l of sterile BHI internally. On each unit a specific prosthetic component was screwed in for each brand and with torques recommended by the manufacturers with digital torque wrench. The sets of Test also received a thin layer of adhesive that was applied with microbrush between the parts; and all units of the Control and Test groups were sealed with provisional obturator material in their most coronal portion. Each set was immersed in 75 l of Enterococcus faecalis (ATCC - 29212) in mini-tubes to the limit between the implant / prosthetic component junction. All samples were incubated in a bacteriological incubator for 7, 14 and 28 days at 37oC before being reopened. After the proposed period, the internal contents of the implants were collected with sterile paper cones, diluted and seeded in Petri dishes, incubated for 48 hours. There was a significant difference between the test and control groups in the hexagonal external connection group at all times (Fischer and Chi-square test, p 0.05). The anaerobic adhesive tested works as a barrier, not allowing the migration of bacteria into the internal environment of the implant / prosthetic component assembly.
Antenucci, Rosse Mary Falcón. "Análise das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexões e qualidade óssea : estudo pelo método dos elementos finitos tridimensionais /." Araçatuba : [s.n.], 2011. http://hdl.handle.net/11449/105562.
Full textCoorientador: Pedro Yoshito Noritomi
Banca: Paulo Sérgio Perri de Carvalho
Banca: Fellippo Ramos Verri
Banca: Marcelo Ferraz Mesquita
Banca: Pedro Tortamano Neto
Resumo: Um aspecto crítico que afeta o sucesso ou falha de um implante é a maneira pela qual as tensões são transferidas do implante ao tecido ósseo. A sobrecarga na prótese dentária pode levar a perda da osseointegração, dessa forma, é aconselhável evitar altas concentrações de tensões no osso de suporte, do ponto de vista clínico. Entretanto, o estresse mecânico pode ter consequências positivas ou negativas no tecido ósseo, fatores esses dependentes de vários fatores associados que podem ser mecânicos ou biológicos. Portanto, o propósito do presente estudo foi analisar a influência da qualidade óssea na distribuição das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexão protética, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados doze modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco com diferentes qualidades ósseas (Tipo I, II, III e IV) e a presença de um implante (4,0x10 mm) com diferente tipo de conexão (Hexágono externo, interno e cone Morse), com coroa metalo-cerâmica. Após geração de geometrias, os modelos foram importados para o programa de pré e pós processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (4 para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: A critical issue that affects the success or failure of an implant is the manner in which the stresses are transferred from the implant to bone tissue. The overload can lead the dental implant to loss of osseointegration, thus it is advisable to avoid high stress concentrations in bone support, according to the clinical point of view. However, mechanical stress can bring positive or negative consequences in the bone tissue and these factors depend on association with mechanical or biological factors. Therefore, the purpose of this study was to analyze the influence of bone quality on stress distribution in implant-prosthesis unit with different types of prosthetic connection, by the three-dimensional finite element method. For this, twelve three-dimensional models were made with the aid of SolidWorks 2010 and Rhinoceros 4.0, graphical modeling software, besides the InVesalius. Each model was composed of a block with different bone qualities (Type I, II, III and IV), an implant (4.0 x 10 mm) with different type of prosthetic connection (Hexagon external, internal and Morse taper) and metal ceramic crown. After generation of geometries, the models were imported into FEMAP 10.2, the pre and post-processing finite element software, where it was generated finite element meshes, boundary and loading conditions. The 200N load was applied axially and 100N obliquely on the occlusal surface of crowns. This total load was divided among the cusps (four points for the axial load and two points for the oblique load on the lingual cusps). Then, the analysis was generated in the FEMAP 10.2 and exported to the NeiNastran version 9.2 software for calculation in finite element analysis, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and... (Complete abstract click electronic access below)
Doutor
Santiago, Junior Joel Ferreira [UNESP]. "Avaliação da influência de diferentes materiais oclusais na confecção de próteses fixas implantossuportadas unitárias com diferentes diâmetros dos implantes osseointegrados: estudo pelo método dos elementos finitos tridimensionais." Universidade Estadual Paulista (UNESP), 2010. http://hdl.handle.net/11449/93588.
Full textFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
A literatura científica ainda é escassa em relação à influência de diferentes materiais na confecção de próteses fixas implantossuportadas unitárias em relação aos diferentes diâmetros dos implantes osseointegrados na distribuição das tensões; as suas manifestações e repercussões na prática clínica ainda não estão totalmente esclarecidas, sendo a fundamentação científica indispensável. Assim, o objetivo desta dissertação foi avaliar a influência do material de revestimento oclusal na confecção de prótese fixa implantossuportada unitária com diferentes diâmetros de implantes osseointegrados. Para o estudo foram elaborados 08 modelos, representando cada qual uma secção de osso mandibular (osso esponjoso e cortical), com a presença apenas de um implante (Conexão Master Screw, Sistemas de Próteses, São Paulo, Brasil) do tipo hexágono externo de 3.75 mm x 10 mm (4 modelos) e de 5.00 mm x 10 mm (4 modelos) com coroas de porcelana feldspática, ou de resina acrílica, ou de resina composta ou coroa liga de NiCr. Para confecção dos modelos foram utilizados os programas de desenho assistido: Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA) e SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA). Os desenhos tridimensionais foram exportados para o programa de elementos finitos NEI Nastran® 9.0 (Noran Engineering, Inc, EUA), para geração da malha, aplicação da carga e análise. Os resultados foram visualizados através dos mapas de tensão von Mises de cada modelo proposto, a fim de avaliar as variações individuais da distribuição das tensões no implante e na coroa; no osso os resultados foram visualizados através dos mapas de tensão máxima principal. Na carga axial (200 N), o osso cortical não mostrou grandes diferenças entre todos os modelos e o osso trabecular sofreu um aumento das tensões por tração...
The scientific literature is still scarce about the influence of different veneering materials used in fabricating superstructures for implant-retained fixed prostheses in relation to different implant diameters on stress distribution, and the manifestations and implications in clinical practice were not clarified. The aim of this dissertation was to evaluate the influence of occlusal material for single implant-supported fixed prostheses with different implant diameters. For this study were simulated 8 models, representing a section of the mandibular bone (trabecular and cortical bone) with a single external hexagonal implant (Master Screw, Conexão Sistema de Prótese ltda., Sao Paulo, Brazil) of 3.75 x 10 mm (4 models) and 5.00 mm x10 mm (4 models) with a crown with different occlusal materials: feldspathic porcelain crowns, or acrylic resin or composite resin crown or NiCr alloy. The models were designed using computer-aided design softwares : Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp., Massachusetts, USA). The three-dimensional designs were exported to the finite element program NEI Nastran® 9.0 (Noran Engineering, Inc, USA) for mesh generation, load application and analysis. The results were visualized through von Mises stress maps of each model, to assess individual variations of the stress distribution on the implant and crown; bone results were visualized through maps of maximum principal stress. In axial loading (200 N), cortical bone showed no significant differences in all models,on the trabecular bone the tensile stress increased, with regular implant diameter. For non-axial loads (100 N), the cortical bone, the tensile stress increased significantly on the side common the load application, when it reduced the implant diameter; in the trabecular bone showed seemed stress patterns, although more... (Complete abstract click electronic access below)
Bacchi, Ataís 1986. "Influência do material de infraestrutura e do desajuste vertical de próteses parciais fixas implantossuportadas nas tensões transmitidas às estruturas protéticas e ao tecido ósseo peri-implantar." [s.n.], 2012. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288548.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-19T19:18:16Z (GMT). No. of bitstreams: 1 Bacchi_Atais_M.pdf: 865962 bytes, checksum: 55e25bc8a48c9b1870a41c704082365a (MD5) Previous issue date: 2012
Resumo: O objetivo neste estudo foi avaliar a influência do material de infraestrutura e diferentes níves de desajuste vertical na concentração de tensões em prótese parcial fixa implantossuportada (infraestrutura e porcelana de cobertura), parafuso de retenção e tecido ósseo peri-implantar durante o assentamento protético e frente à aplicação de carga oclusal. Um modelo tridimensional de elementos finitos de uma porção posterior de mandíbula contendo dois implantes osseointegrados nas posições de segundo pré-molar e segundo molar, suportando uma prótese parcial fixa foi construído utilizando software específico de modelagem (SolidWorks 2010). Modelos de elementos finitos foram obtidos pela importação do modelo sólido ao software de simulação mecânica (ANSYS Workbench 11). Os modelos foram separados em grupos de acordo com o material de infraestrutura (liga de ouro tipo IV, liga de prata-paládio, titânio comercialmente puro, liga de cobalto-cromo ou zircônia) e o nível de desajuste vertical (10 ?m, 50 ?m e 100 ?m) criado na interface prótese-implante do segundo pré-molar. A concentração de tensões foi avaliada nas seguintes condições: (1) assentamento protético; e (2) cargas oclusais simultâneas de 110 N vertical e 15 N horizontal em cada dente. Os resultados obtidos mostraram que as infraestruturas mais rígidas apresentam maior concentração de tensões internas; entretanto, promoveram menores concentrações de tensão sobre a porcelana de recobrimento, em ambas condições avaliadas. Na análise do assentamento protético, materiais mais rígidos para infraestruturas aumentaram os valores de tensão no parafuso de retenção e não causaram diferença relevante nas tensões no tecido ósseo peri-implantar. Quando a carga foi aplicada, o uso de infraestruturas mais rígidas promoveu redução de tensões no parafuso de retenção e no tecido ósseo peri-implantar. Em ambas condições avaliadas um considerável aumento na concentração de tensões foi obsevado em todas as estruturas com a amplificação do desajuste. Nas diferentes simulações, o material de infraestrutura exerceu considerável influência nas tensões transmitidas às estruturas avaliadas, exceto ao tecido ósseo peri-implantar em condições de assentamento. Aumento de tensões em todas as estruturas pode ser observado com o aumento do desajuste
Abstract: The aim in this study was to evaluate the influence of the framework material and vertical misfit on the stresses created in an implant-supported partial prosthesis (framework and porcelain veneer), retention screw and peri-implant bone tissue during the settlement of the prosthesis and under load conditions. A 3-D Finite Element model of a posterior part of a jaw with two osseointegrated implants at the place of the right second pre-molar and second molar supporting an implant-supported fixed partial prosthesis was constructed using specific modeling software (SolidWorks 2010). Finite element models were obtained by importing the solid model into mechanical simulation software (ANSYS Workbench 11). The models were divided into groups according to the framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy or zirconia) and vertical misfit level (10 ?m, 50 ?m and 100 ?m) created at the second pre-molar implant-prosthesis interface. The stress concentration was evaluated in the following conditions: (1) settlement of the prosthesis; and (2) simultaneous loads of 110 N vertical and 15 N horizontal in each tooth. The obtained results showed that stiffer frameworks presented higher stress concentrations in it and led to lower stresses in the porcelain veneer, in both conditions. In the analysis of settlement of the prosthesis, stiffer framework materials increased the stress values in the retention screw and did not cause a relevant difference in the stresses values in peri-implant bone tissue. When the load was applied, the use of more stiffness frameworks led to lower stresses in the retention screw, and peri-implant bone tissue. In both conditions evaluated, considerable raise of stress concentration was observed in all the structures within misfit amplification. Comparing the results of the different simulations, the framework materials presented a considerable influence on the stress concentration in the structures evaluated, except on the peri-implant bone tissue during the settlement of the prosthesis, while a considerable increase of the stress in all the structures was observed with the increase of the misfit
Mestrado
Protese Dental
Mestre em Clínica Odontológica
Ayub, Karen Vaz. "Avaliação clínica e radiográfica de implantes utilizados como pilares de próteses inferiores implantossuportadas do tipo protocolo, colocadas sob carga imediata, empregando dois sistemas reabilitadores após 7 anos." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/25/25146/tde-03122013-164207/.
Full textThis study evaluated the success of implants used to support mandibular complete full-arch fixed prosthesis employing two rehabilitation systems with immediate loading after 7 years. The following aspects were investigated: plaque and bleeding index, implant stability by resonance frequency analysis and marginal bone loss. The 76 implants were evaluated in 19 patients divided in 2 groups: A (n=12, All-on-four® - Nobel Biocare®) and B (n=7, Neopronto® - Neodent®). The follow-up visits were at the time of implant placement (initial), 6 months, 1, 2 and 7 years after surgery. The results showed a success rate of 100% for implants in group A and 90% for group B. The plaque index did not differ statistically signifcant and were in group A, 71.87%, 63.54% and 47.92%, and in group B 26.78%, 41.07% and 37, 50% for 1, 2 and 7 years of follow-up, respectively. The bleeding index for group A was 43.75%, 42.71% and 43.75% and for group B was 53.57%, 51.79% and 48.21%, for 1, 2 and 7 years of follow-up, respectively, no statistical differences. Suppuration was not observed at any time of evaluation. The results of FR did not differ significantly between groups, however, decreased between initial (group A = 69,27ISQ and group B = 68,29 ISQ) and 6 months (group A = 64,65ISQ and group B = 66,50ISQ), and increased in the following evaluations for both groups, in group A was 66,17ISQ, 66,05ISQ and 69,87ISQ and group B was 67,78ISQ, 68,13ISQ and 73,61ISQ for 1, 2 and 7 years of follow-up, respectively. In relation to bone loss, a significant difference existed between groups and was 0,49mm and 0,67 mm after 1 year and 1,03mm and 1,27mm after 7 years, for groups A and B, respectively. Regarding the position of the implants, group B showed statistical difference between the central and distal implants for FR and bone loss. It was concluded that 1- Success rate was 100% for group A and 90% for group B; 2 - Plaque and bleeding index decreased over the follow-up; 3- FR was similar between groups, but with a significant difference in group A for thw criterion time, and in group B for the criteria evaluation times and position of the implants, 4- bone loss was significantly different between groups, and higher in group B.
Barão, Valentim Adelino Ricardo [UNESP]. "Avaliações biomecânicas e biológicas relacionadas às próteses implanto-suportadas e aos implantes osseointegrados." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/105565.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Objetivos: (1) Investigar o papel de diferentes níveis de pH da saliva artificial (3; 6,5 e 9) no comportamento corrosivo do titânio comercialmente puro (cp-Ti) e da liga Ti-6Al-4V (Capítulo 1); (2) Avaliar a influência do processo de corrosão na afinidade do lipopolissacarídeo (LPS) de Escherichia coli para o cp-Ti e o Ti-6Al-4V (Capítulo 2); (3) Investigar a natureza tribocorrosiva do titânio em saliva artificial em presença de LPS (Capítulo 3); (4) Comparar o efeito de diferentes designs de overdentures implanto-retidas e prótese total fixa implanto-suportada na distribuição de tensões em mandíbula edêntula pelo método de elementos finitos tridimensional (Capítulo 4). Materiais e métodos: Testes eletroquímicos como potencial de circuito aberto, espectroscopia de impedância eletroquímica, e teste potenciodinâmico foram conduzidos. Para o teste de afinidade ao LPS, os espécimes foram tratados com LPS (1,5; 15 e 150 μg/ml) durante 24 horas para avaliar a aderência de LPS. Os discos foram transferidos a cada 24 horas para solução fresca de água livre de LPS até completar 72 horas, para investigar a liberação de LPS. No teste de tribocorrosão, o pH da saliva (6,5), a concentração de LPS (0, 0,15, 15 and 150 μg/ml), a duração do deslizamento (2000 ciclos), freqüência (1,2 Hz) e carga (20 N) foram usados para mimetizar o processo mastigatório. Finalmente, modelos tridimensionais de uma mandíbula edêntula foram construídos. No grupo OR a mandíbula foi restaurada com overdenture retida por implantes não esplitados com sistema de retenção O’ring; nos grupos BC-C e BC as mandíbulas foram restauradas com overdentures retidas por implantes esplintados com sistema de retenção barra-clipe associado ou não a cantilevers distais...
Objectives: (1) To investigate the role of different levels of pH of artificial saliva (pHs 3, 6.5 and 9) under simulated oral environment on the corrosion behavior of commercially-pure titanium (cp-Ti) and Ti-6Al-4V alloy (Chapter 1); (2) To assess the influence of corrosion process on Escherichia coli lipopolysaccharide (LPS) affinity for cp-Ti and Ti-6Al-4V alloy (Chapter 2); (3) To evaluate the tribocorrosive (corrosion/wear) nature of titanium in artificial saliva (pH 6.5) with LPS (Chapter 3); and (4) To compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible by using a three-dimensional finite element analysis. Materials and methods: Standard electrochemical tests, such as open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic tests were conducted in a controlled environment. For LPS affinity test, specimens were treated with LPS (1.5, 15 and 150 μg/ml) for 24 hours to evaluated LPS adherence. Discs were then transferred every 24 hours to fresh LPS-free water, up to 72 hours, to investigate LPS elution. In the tribocorrosion test, the pH of saliva (6.5); LPS concentration (0, 0.15, 15 and 150 μg/ml), sliding duration (2000 cycles), frequency (1.2Hz) and load (20 N) parameters mimicked the mastication process. Finally, tridimensional models of an edentulous mandible were constructed. In the OR group, the mandible was restored with an overdenture retained by unsplinted implants with O’ring attachment; in the BC-C and BC groups, the mandibles were restored with overdentures retained by splinted implants with bar-clip anchor associated or not with distally placed cantilevers, respectively; in the FD group, the mandible was restored with a fixed full-arch implant-supported prosthesis... (Complete abstract click electronic access below)
Oliveira, Janisse Martinelli Borges de. "Análise fotoelástica de tensões transmitidas a implantes curtos." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/58/58131/tde-21092011-150827/.
Full textThe aim of this study was to evaluate by the photoelastic method, stress transmission to implants of different lengths by metal-ceramic crowns under different loads, and how crown/implant ratio influenced this stress distribution. From four matrixes, four photoelastic models (Araldite) were made simulating free mandibular end, with teeth 44 in resin (Luxatemp) and tooth 45, 46 and 47 replaced by implants with 4 mm in diameter. Group 1 (G1) was formed by two implants with conventional length or long (11 mm; Titamax Cortical CM, Neodent) replacing tooth 45 and 46, and one short implant (5 mm; Ws Cortical CM, Neodent) replacing the 47. Group 2 (G2) had one implant with 11 mm (45) and 2 implants with 5 mm (46 and 47). Group 3 (G3) was rehabilitated by three implants of 5 mm and group 4 (G4) for 3 implants of 11 mm in length. In the groups with 5 mm implants was simulated 4 mm bone resorption in height. Metal-ceramic fixed prosthesis was bolted on the abutments. Different oclusal loads were performed over the crowns, 150N in occlusal balanced, 100N on the 45 mesial, and 100N on the 47 distal. Quantitatively photoelastic analysis determined the stress transmitted (MPa) on the groups: G1 (84.73), G2 (136.36), G3 (126.77) and G4 (164.72) for the occlusal load balanced, G1 (91.66), G2 (70.93), G3 (93.08) and G4 (119.82) for charging on the 45 mesial, and G1 (75.22), G2 (70.88), G3 (93.79) and G4 (117.56) to the load on the 47 distal. Crown/implant ratio for short implants was greater than 2.5 and for long implants was about 1. After analysis, it was concluded that the highest values of strains were found in the group with three long implants (G4), and the increased crown/implant ratio showed no correlation with the highest stress concentration. Comparatively, the use of short implants reduced stress around the implants.
Mouchet, Frédéric. "Les implants cochléaires : technique chirurgicale et complications." Montpellier 1, 1996. http://www.theses.fr/1996MON11051.
Full textTolentino, Lívia de Souza. "Estudo clínico randomizado e controlado de implantes de diâmetro reduzido confeccionados em titânio puro e uma liga de titânio/zircônico instalados em área de molares inferiores: resultados de 1 ano de acompanhamento." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/23/23146/tde-18032015-164124/.
Full textThe aim of the present randomized controlled trial study was to analyze marginal bone loss (MBL) and clinical parameters around narrow-diameter implants (NDIs - 3.3 mm) made of titanium/zirconium alloy (TiZr) in comparison to commercially pure titanium (cpTi) installed in the molar region of the mandible after one year in function. Ten patients participated in the study. A TiZr and a cpTi NDI were randomly installed in contralateral molar sites of the mandible of each patient in a split-mouth design. Eight weeks after healing, all metal-ceramic single crowns were adapted to the implants and patients were enrolled in a plaque control program. MBL at the mesial and distal aspects of the implants were evaluated by comparing periapical radiographs taken immediately after prosthesis installation (T1) and one year after loading (T2). Clinical probing depth, bleeding on probing, suppuration, visible plaque, and implant mobility were evaluated to determine implant success and survival rates. Mean MBL at the interproximal aspects of TiZr implant sites was 0.32±0.27 mm, while at cpTi implant sites MBL was 0.35±0.24 mm (p> 0.05). Both TiZr and cpTi NDIs presented 100% implant survival and success rates, with no significant differences in the clinical parameters studied (p> 0.05). In conclusion, TiZr and cpTi NDIs presented similar outcomes after one year in function in the molar region of the mandible. The results suggest that TiZr and cpTi NDIs may be equally used to support single crowns in the posterior area of the mouth. However, further studies with longer follow-up periods are necessary to confirm these findings.
Gastaldo, José Fabio Guastelli. "Análise fotoelástica das tensões ao redor dos implantes, na região de mandíbula, com aplicação de força em próteses tipo protocolo, revestidas em resina acrílica." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/23/23150/tde-29052013-154831/.
Full textThe purpose of this study was to analyze, using the photoelasticity method, the behavior of stresses occurring in peri-implant structures and fixed prosthesis supports following Brånemark protocol that are screwed on five implants of different lengths, 10mm; 13mm and 15mm, when submitted to occlusal loads. Three mandible photoelastic models were built: MD10; MD13 and MD15, with five implants each, 3.75mm of internal diameter and located in parallel with each other in the interforaminal region. Microunit pillars were installed on each implant model with a 1mm-belt, and a single prosthesis was installed over them with a cobalt/chrome metallic infrastructure covered with thermoplastic acrylic resin. Loads of 1.0 and 3.0 bars were applied and images were photographed and evaluated. Results showed that highest tensions occurred in 10mm-length implants; the patterns of stresses was the same in implants of different lengths and only the magnitude of stresses changed along implant body. The greater the length the lower the stress in the analyzed region of the model. We concluded that: 1) The implants of greater length tension better distributed along the body of the implant. 2) Tensions were located more apically by both mesial and distal implants of greater length. 3) The implants have suffered greater tensions were the closest to the cantilever and implant center.
Vasconcelos, Laércio Wonhrath [UNESP]. "Avaliação clínica e da freqüência de ressonância, de implantes instalados por meio de técnica cirúrgica modificada na maxila e submetidos à função imediata." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/103321.
Full textUniversidade Estadual Paulista (UNESP)
Brånemark et al. (1969) introduziram os implantes osseointegrados como forma de ancoragem para próteses com intuito de substituir os dentes perdidos, tanto na mandíbula como na maxila. Desde então, foram instituídas modificações no protocolo clássico. Entre elas, a submissão dos implantes à função imediatamente após a sua instalação. Esse procedimento tem sido largamente estudado na mandíbula, com altos índices de sucesso, contudo, a literatura é escassa quanto à aplicação desta técnica na maxila. Propôs-se, então, avaliar a função imediata em implantes instalados em maxilas desdentadas totais, no momento da cirurgia e após seis e 12 meses de função. Para tanto foi utilizada uma técnica cirúrgica modificada e a avaliação da estabilidade dos implantes foi feita por meio da análise da freqüência de ressonância. Foram selecionados 10 pacientes, nos quais foram instalados seis implantes na maxila com a submissão dos mesmos à função imediata mediante a instalação de uma prótese fixa, com infra-estrutura metálica, 24 horas após a cirurgia. Estes pacientes foram acompanhados por um período de 12 meses. As medidas da estabilidade do implante foram realizadas no momento da instalação dos implantes (M0) e após seis (M6) e 12 meses (M12). Após o período de acompanhamento, foram obtidos índices de sucesso de 95% para os implantes e 90% para as próteses. Quanto aos valores da estabilidade dos implantes, foi observada uma diferença estatisticamente significativa entre os valores de M0 e M6, e, M0 e M12. Sendo o M0, o momento com maior valor do coeficiente de estabilidade. Não houve diferença estatisticamente significativa entre os valores da estabilidade obtidos no M6 e M12. Quando comparados, o valor da estabilidade para cada implante, não apresentaram diferença estatisticamente significativa no mesmo período de avaliação...
Brånemark et al. (1969) presented the osseointegrated implants as a way to anchorage prosthesis for missing teeth substitution in the jaws. Ever since, modifications in the classical protocol were instituted. Among them, the functional loading of the implants, immediately after their installation. This procedure have been well documented in mandibles, with high success levels, however, literature is scarce about the application of this technique in maxilla. The purpose of this study is to evaluate the immediate function in implants installed in totally edentulous maxillas, at the surgical moment and after six and 12 months of function. For so much, a modified surgical technique was used and implant stability was evaluated through the resonance frequency analysis. Ten patients were selected, who received six implants installed in the maxilla and submitted to immediate function. A metallic infra-structure fixed prosthesis was installed 24 hours after the surgery. The follow-up period was of 12 months. Implant stability measurements were taken at the surgical moment (M0) and after six (M6) and 12 months (M12). After the follow-up period, success rates of 95% for implants and 90% for prosthesis were achieved. As for the implant stability values, significant statistical difference were observed between M0 and M6, and M0 e M12, and no significant statistical difference was observed between M6 and M12. When the stability values of each implant was compared, no significant statistical difference was observed between them for different evaluation periods. It is concluded that the submission of implants, installed in the maxilla through a modified technique, to immediate function is a well predictable procedure, ever since well selected and executed. The resonance frequency analysis is an efficient method for the evaluation of the initial and late implants’ stability.
Villa, Luiz Marcelo Ribeiro [UNESP]. "Estudo das tensões em próteses sobre implantes esplintadas: análise pelo método da fotoelasticidade." Universidade Estadual Paulista (UNESP), 2013. http://hdl.handle.net/11449/108703.
Full textPropósito: O objetivo deste estudo foi avaliar a influência da esplintagem e de diferentes comprimentos de implantes na distribuição de tensões em próteses implantossuportadas, sob carregamento axial e oblíquo, por meio do método da fotoelasticidade. Materiais e métodos: Um total de 05 modelos em resina fotoelástica foi confeccionado com diferentes situações propostas, realizaram-se 400 aplicações de carga para análise. As tensões foram consideradas de forma quantitativa e qualitativa utilizando um método randomizado e simples cego. A reprodutibilidade do estudo foi avaliada usando o coeficiente de correlação intra-examinador (CCI), erro sistemático e erro casual. A análise de variância a três critérios e pós-teste de Tukey foram utilizados e, valor de p>0.05 foi adotado para analisar as principais diferenças. Resultados: As mensurações mostraram elevado coeficiente de concordância intraexaminador (CCI>0.97). A esplintagem de próteses implantossuportadas agiu favoravelmente na distribuição de tensões e na transmissão de tensões para o implante adjacente (p<0.001), quando comparado a próteses unitárias. O carregamento oblíquo foi mais prejudicial e, pontecializou a formação de tensões em implantes adjacentes (p<0.001). O aumento do comprimento foi um fator significante na avaliação dos modelos B e C (p=0.004), o modelo B apresentou maior concentração de franjas quando comparado com D e E (p<0.001). Conclusão: As próteses implantossuportadas esplintadas comportaram-se melhor biomecanicamente quando comparadas as próteses unitárias. O aumento do comprimento teve relevância na redução de tensões. O carregamento oblíquo foi mais prejudicial para a distribuição de tensões quando comparado com o carregamento axial.
Purpose: The purpose of this study was to evaluate the influence of different lengths and splinting of implants on stress distribution in implant-supported prostheses under axial and oblique loading by means of the method of photoelasticity. Materials and methods: 05 models in photoelastic resin was prepared with different proposed situations, there were 400 applications for load analysis. Tensions were considered quantitatively and qualitatively using a randomized, single blind method. The reproducibility of the study was assessed using the intra correlation coefficient, systematic error and random error. The analysis of variance to three criteria and post - Tukey tests were used, and p values > 0.05 was adopted to analyze the main differences. Results: The measurements showed a high intra-concordance coefficient (ICC> 0.97). The prosthetic implant splinting acted favorably in the distribution of stresses and strains in the transmission next to the implant (p<0.001) when compared to the unitary prosthesis. The oblique loading was more damaging and potentialized the formation of stresses in adjacent implants (p<0.001). The increase in length was a significant factor for the evaluation of the models B and C (p = 0.004), the model B had a higher concentration of fringes as compared with D and E (p<0.001). Conclusion: The prosthetic implant splinted behaved better biomechanically compared prosthetics unit. The increased length was important in reducing stress. The oblique loading was more detrimental to the stress distribution compared to axial loading.
Villa, Luiz Marcelo Ribeiro. "Estudo das tensões em próteses sobre implantes esplintadas : análise pelo método da fotoelasticidade /." Araçatuba, 2013. http://hdl.handle.net/11449/108703.
Full textBanca: Marcelo Coelho Goiato
Banca: Stefan Fiuza de Carvalho Dekon
Banca: Regina Tamaki
Banca: Sandra Lúcia Dantas de Moraes
Resumo: Propósito: O objetivo deste estudo foi avaliar a influência da esplintagem e de diferentes comprimentos de implantes na distribuição de tensões em próteses implantossuportadas, sob carregamento axial e oblíquo, por meio do método da fotoelasticidade. Materiais e métodos: Um total de 05 modelos em resina fotoelástica foi confeccionado com diferentes situações propostas, realizaram-se 400 aplicações de carga para análise. As tensões foram consideradas de forma quantitativa e qualitativa utilizando um método randomizado e simples cego. A reprodutibilidade do estudo foi avaliada usando o coeficiente de correlação intra-examinador (CCI), erro sistemático e erro casual. A análise de variância a três critérios e pós-teste de Tukey foram utilizados e, valor de p>0.05 foi adotado para analisar as principais diferenças. Resultados: As mensurações mostraram elevado coeficiente de concordância intraexaminador (CCI>0.97). A esplintagem de próteses implantossuportadas agiu favoravelmente na distribuição de tensões e na transmissão de tensões para o implante adjacente (p<0.001), quando comparado a próteses unitárias. O carregamento oblíquo foi mais prejudicial e, pontecializou a formação de tensões em implantes adjacentes (p<0.001). O aumento do comprimento foi um fator significante na avaliação dos modelos B e C (p=0.004), o modelo B apresentou maior concentração de franjas quando comparado com D e E (p<0.001). Conclusão: As próteses implantossuportadas esplintadas comportaram-se melhor biomecanicamente quando comparadas as próteses unitárias. O aumento do comprimento teve relevância na redução de tensões. O carregamento oblíquo foi mais prejudicial para a distribuição de tensões quando comparado com o carregamento axial.
Abstract: Purpose: The purpose of this study was to evaluate the influence of different lengths and splinting of implants on stress distribution in implant-supported prostheses under axial and oblique loading by means of the method of photoelasticity. Materials and methods: 05 models in photoelastic resin was prepared with different proposed situations, there were 400 applications for load analysis. Tensions were considered quantitatively and qualitatively using a randomized, single blind method. The reproducibility of the study was assessed using the intra correlation coefficient, systematic error and random error. The analysis of variance to three criteria and post - Tukey tests were used, and p values > 0.05 was adopted to analyze the main differences. Results: The measurements showed a high intra-concordance coefficient (ICC> 0.97). The prosthetic implant splinting acted favorably in the distribution of stresses and strains in the transmission next to the implant (p<0.001) when compared to the unitary prosthesis. The oblique loading was more damaging and potentialized the formation of stresses in adjacent implants (p<0.001). The increase in length was a significant factor for the evaluation of the models B and C (p = 0.004), the model B had a higher concentration of fringes as compared with D and E (p<0.001). Conclusion: The prosthetic implant splinted behaved better biomechanically compared prosthetics unit. The increased length was important in reducing stress. The oblique loading was more detrimental to the stress distribution compared to axial loading.
Doutor
Pérez, Delgado José Delfín. "Prótese implanto‒suportada aparafusada vs. cimentada." Master's thesis, [s.n.], 2015. http://hdl.handle.net/10284/5069.
Full textA procura de reabilitações orais cada vez mais próximas dos dentes naturais contribuiu para a evolução das técnicas de reabilitação oral, nomeadamente na área da implantologia, onde atualmente são levantados vários paradigmas, entre os quais se encontra a discussão entre a utilização de próteses cimentadas versus as próteses aparafusadas. Neste trabalho é feita uma revisão da literatura e uma comparação em relação aos dois tipos de retenção de prótese fixas implanto‒suportadas. Para isso foram analisados vários fatores com influência no sucesso ou insucesso dos dois tipos de restaurações como: estética, oclusão, resistência, retenção, biomecânica, reversibilidade, ajuste passivo, efeitos biológicos, provisionalização, função imediata e hábitos parafuncionais. A resposta a esta discussão só é possível de ser obtida após uma exaustiva avaliação de cada caso de reabilitação, ponderando as vantagens e desvantagens de cada técnica, não havendo uma resposta geral para a questão de qual o melhor tipo de retenção. The search for oral rehabilitations more and more close from the natural teeth had contributed for the evolution of the oral rehabilitation techniques, namely in the implantology field, where nowadays are lifted several paradigms, among which is the discussion among the use of cement‒retained or screw‒retained prostheses. In this work it is done a literature review and a comparison in relation to the both types of implant‒supported fixed prostheses retention.For that propose several factors with influence on the success or failure of the both type of restorations were analyzed, such as: aesthetics, occlusion, resistance, retention, biomechanics, retrievability, passivity, biological effects, provisionals, immediate function and parafunctional activity. The answer to this discussion it’s only obtained after an exhaustive evaluation of each rehabilitation case, considering the advantages and disadvantages of each technique, without having a general answer for the question which is the best type of retention.
Alves, Suleima do Vale. "Análise da durabilidade, retenção e tensão em overdentures retidas por implantes associadas ou não a mini-implantes posteriores." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/58/58131/tde-01092017-102655/.
Full textThe purpose of this in vitro study was to analyze the durability, retention and strength caused for implants-retained overdentures by ball/O-ring system or bar/clip, associated or not mini-implants in the posterior region of the mandible. Anterior Morse taper connection implants (3.75 x 11 mm) and single-body mini-implants (2 x 10 mm) were used and the groups divided to (n=12): G2O: implants-retained overdentures 2 implants with ball/O-rings ; G1B: implants-retained overdentures 2 bar/clip implants; G4O: implants-retained overdentures 2 implants with ball/O-rings and 2 mini-implants in the posterior region ; G1B2O: implants-retained overdentures 2 implants with bar/clip and 2 mini-implants in the posterior region. For the qualitative evaluation of compression and/or traction areas in polyurethane models, a digital image correlation method (DIC) with occlusal (300 N) and punctual (250 N) loading was applied with frontal and lateral views of the experimental models. An accelerated progressive fatigue test with loads of 80 N, 140 N, 200 N, 260 N, 320 N and 380 N, frequency of 5 Hz, completing120,000 cycles. In order to evaluate the retention force, the models were submitted to traction force, previously to thermocycling (Time 1) after 200 N (Time 2) and posteriorly 380 N (Time 3), being the retention force recorded in triplicate. The durability analysis, by optic microscopy, of the retentive components was performed after the traction tests at the determined times. The application images of the occlusal load, showed that the stress in groups 1B and 1B2O were similar, in groups 2O and 4O presented stress in the anterior region, but in the 4O group, there was better distribution throughout the analyzed area. In the application of punctual loading, all the models presented compression tensions in the posterior region and traction in the anterior one, but with greater intensity in the 2O and 4O models, and lower intensity in the 1B and 1B2O models. In the retention analyzes of the components, there was no significant difference (p <0.05) between groups 1B-1B2O, but there was a significant difference between groups 2O-4O, noting a higher retentive force in the 4O group. The comparisons between the groups, 1B-2O and 1B2O-4O showed a significant difference, and the groups with bar/clip systems obtained higher retention than the groups with O-rings. In the microscopic images, there was no significant difference in the O-rings internal structure, but there was a significant difference in the clips images. It was concluded that the durability, retention and stress distribution do not change with the placement of posterior mini-implants in overdentures with retentive bar/clip system. With retentive system ball/O-ring the installation of mini-implants increased the retention force and favored much the distribution of the stress, thus reducing the forefoot leverage to the posterior part of the prosthesis.
Pimentel, Gustavo Henrique Diniz [UNESP]. "Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four." Universidade Estadual Paulista (UNESP), 2014. http://hdl.handle.net/11449/145513.
Full textO assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar in vitro a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema All-on-four). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo)
Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate in vitro the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating All-on-four system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below)
Pimentel, Gustavo Henrique Diniz. "Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four /." Araraquara, 2014. http://hdl.handle.net/11449/145513.
Full textBanca: Marco Antônio Compagnoni
Banca: Janaína Habib Jorge
Banca: Estevam Augusto Bonfante
Banca: Ricardo Faria Ribeiro
Resumo: O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar "in vitro" a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema "All-on-four"). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo)
Abstract: Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate "in vitro" the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating "All-on-four" system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below)
Doutor
Almeida, Daniel Augusto de Faria. "Avaliação da influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões : estudo pelo método dos elementos finitos tridimensionais /." Araçatuba : [s.n.], 2011. http://hdl.handle.net/11449/97362.
Full textCoorientador: Fellippo Ramos Verri
Banca: Estevão Tomomitsu Kimpara
Banca: Marcelo Coelho Goiato
Resumo: O comportamento biomecânico de um implante dentário osseointegrado desempenha um importante papel na sua longevidade funcional. As limitações anatômicas às vezes tornam necessário o posicionamento de implantes com angulações fora do considerado ideal para as reabilitações protéticas, havendo maior concentração de tensões e reabsorção no osso cortical ao redor do implante. Para solucionar tais situações o profissional deve lançar mão de um cuidadoso planejamento e uso de intermediários angulados, estudando qual conexão protética melhor se adapta a situação clínica. Portanto, o propósito do presente estudo foi analisar a influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados seis modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco ósseo e a presença de um implante (4,0x10 mm) com diferentes angulações (0º, 17º e 30º) e tipos de conexão (Hexágono externo e cone morse), com coroa metalo-cerâmica. Após geração das geometrias, os modelos foram importados para o programa de pré e pós-processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (quatro para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos NeiNastran versão 9.2, executada em uma estação de trabalho... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The biomechanical behavior of an osseointegrated dental implant plays an important role in the longevity. The anatomical limitations sometimes require the placement of implants with angles outside the considered ideal for prosthetic rehabilitation, with higher stress concentration and resorption in cortical bone around the implant. Thus, in some situations, the professional should planning careful the treatment and use the abutment, analyzing the prosthetic connection which best fits the clinical situation. Therefore, the purpose of this study was to analyze the influence of the implant angulation with different types of prosthetic connection on the stress distribution, by three-dimensional finite element method. Six three-dimensional models were made with the aid of the graphical modeling and SolidWorks 2010 Rhinoceros 4.0 and InVesalius.Each model was composed of a bone blockwith an implant (4.0 x 10 mm) with different angulations (0, 17 and 30) and connection types (Hexagon external and Morse taper) with metal-ceramic crown. After generation of the geometries, the models were imported into the pre-and post-processing finite element FEMAP 10.2, where we generated finite element meshes, boundary and loading conditions. The load was applied axial 200N and 100N obliquely to the occlusal surface of crowns. This total load was divided between the cusps (four for the axial load and two oblique lingual to the load). Then, the analysis was generated in and exported 10.2 FEMAP software for calculation in finite element program NeiNastran version 9.2, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and maximum principal stress. The maps for... (Complete abstract click electronic access below)
Mestre
Gomes, Maria Helena Garcia. "Análise fotoelástica das tensões ao redor das estruturas peri-implantares, suportes de próteses fixas com revestimento em cerâmica." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/23/23150/tde-10092013-200840/.
Full textThe purpose of this research was to evaluate, using the photoelastic method, the behavior of tensions on peri-implant-supported structure deriving from pressure applied to a ceramic-coated fixed prosthesis . Three photoelastic-resin mandibles were built, each of them containing five 3.75-mm external hexagon implants with variable lengths and denominated MOD10 (implants with 10mm), MOD13 (implants with 13mm), MOD15 (implants with 15mm), located in parallel with each other in the interforaminal region. A fixed cobalt/chrome prosthesis structure was built with 15mm-bilateral-distal-length (cantilever), coated in ceramic, and screwed onto microunit pillars with a 1.0mm belt. A proper oclusal adjustment was performed at maximum intercuspation between antagonistic teeth. Models were submitted to pressures of 1.0 and 3.0 bars applied on implants at axial ends. Their behavior was evaluated by direct real-time visualization and by photographic images. Results showed that the greater the implant length, the greater the propagation of tension along implant length and on its apices; implants distally located, next to the cantilever, presented greater tensions in relation to others; as implant length increase, propagation of tension along the mandibular structure, such as the mandible body and ascending arm, also increase. Conclusion was 1. The longer the fixed-prosthesis-supported implant, coated in ceramic, the more tensions are distributed along its body and apex, propagating along mandibular structures. 2. Implants closer to the cantilever are those supporting the highest load and presenting the highest tensions.
Caneva, Marco [UNESP]. "Influência de implantes pós-exodônticos com diferentes configurações sobre os tecidos peri-implantares: estudo experimental em cães." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/103315.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Objetivo: avaliar a influência da instalação de implantes em alvéolos imediatamente após a extração do elemento dental na regeneração dos tecidos peri-implantares com implantes de diferentes configurações Material e métodos: Nos alvéolos distais dos quartos pré-molares mandibulares de cães, imediatamente após as extrações das raízes dentais, foram instalados implantes cilíndricos com 3,3 mm de diâmetro (grupo controle) e implantes cônicos com 5,0 mm de diâmetro (grupo teste). Foram avaliados histologicamente a regeneração dos tecidos duros e moles peri-implantares após 4 meses do procedimento cirúrgico. Resultados: Todos os implantes apresentaram-se osseointegrados ao tecido ósseo maduro mineralizado. A crista óssea alveolar sofreu reabsorção tanto no grupo teste como controle. A superfície óssea vestibular dos implantes do grupo teste (cônico; 3,6 mm) apresentou maior grau de reabsorção em comparação ao grupo controle (cilíndrico; 1,6 mm). As dimensões dos tecidos moles apresentaram-se semelhantes em ambos os grupos. No entanto, em relação ao ombro do implante, a mucosa peri-implantar localizou-se mais apicalmente no grupo teste em relação ao grupo controle. Conclusão: Este estudo confirmou que a distância entre a superfície do implante e o contorno externo da crista óssea alveolar vestibular influenciou no grau de reabsorção da tábua óssea vestibular. Conseqüentemente, em relação ao ombro do implante, a mucosa peri-implantar será estabelecida em um nível mais apical, se a distância entre a superfície do implante e o contorno externo da crista óssea alveolar for menor
Aim: the aim of the present experiment was to study the influence of implant installation into sockets immediately after tooth extraction on the healing periimplant tissues with implants of various configurations. Material & methods: Transmucosal cylindrical 3.3mm in diameter implants in the control sites, and conical 5.0mm in diameter in the test sites, were installed into the distal socket of the forth mandibular premolars in dogs immediately after tooth extraction. After 4 months, the hard and soft tissue healing was evaluated histologically. Results: All implants were integrated in mineralized mature bone. Both at the test and control sites, the alveolar crest underwent resorption. The buccal bony surface at the implant of the test sites (conical; 3.6mm) was more resorbed compared to the control sites (cylindrical; 1.6mm). The soft tissue dimensions were similar in both groups. However, in relation to the implant shoulder, the periimplant mucosa was located more apically at the test compared to the control sites. Conclusion:The present study confirmed that the distance between the implant surface and the outer contour of the buccal alveolar bony crest influenced the degree of resorption of the buccal bone plate. Consequently, in relation to the implant shoulder, the peri-implant mucosa will be established at a more apical level if the distance between the implant surface and the outer contour of the alveolar crest is small
Perez, Miguel Angel Jaimes. "Influencia do desenho dos implantes endosseos na distribuição de tensões apos aplicação de cargas verticais e obliquas : analise estrutural e fotoelastica." [s.n.], 2008. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289425.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-11T23:04:29Z (GMT). No. of bitstreams: 1 Perez_MiguelAngelJaimes_M.pdf: 6909101 bytes, checksum: 41413f644c388e8bd46795ab371670ee (MD5) Previous issue date: 2008
Resumo: Este estudo teve como objetivo analisar a influência do desenho dos implantes endósseos na distribuição de tensões geradas nos modelos fotoelásticos após aplicação de cargas verticais e oblíquas a 7,5N, em quatro marcas comerciais de implantes endósseos. Foram selecionados doze implantes, divididos em quatro grupos: I.) Máster Conect Cônico1 4,3 x 13 mm; II.)Titamax Ti Medular2 3,75 x 13 mm; III.) Colosso3 RC 4,0 x 13mm; IV.) Bicon Uncoated Implant4 3,5 x 11mm, cada grupo contendo 3 implantes da mesma marca comercial. Através da Microscopia Eletrônica de Varredura foi analisado o desenho estrutural dos implantes. Para a análise da distribuição de tensão foram confeccionados oito modelos em resina fotoelástica com dimensões de 40 mm x 10 mm de base e 30 mm de comprimento. Dois implantes para cada grupo foram posicionados e fixados no interior dos modelos fotoelásticos. Uma vez verificada a ausência de tensões nos oito modelos foram iniciados os ensaios. Quatro modelos dos diferentes grupos receberam cargas verticais e quatro receberam cargas oblíquas de 7,5N. Por meio do polariscópio circular pertencente ao laboratório de Materiais Dentários e Prótese da USP-Riberão Preto, foi possível visualizar as franjas de tensões geradas nos modelos. Cada seqüência foi fotografada, sendo mantida a mesma distância focal em todos os ensaios. Os resultados obtidos foram analisados por grupos. O Grupo I, implante de hexágono interno longo com porção cervical polida, topo das roscas arredondadas, passos das roscas contínuas, espirais angulados e configuração cônica, apresentou concentração das tensões na região apical, quando submetida à carga vertical e oblíqua. O Grupo II, implante de hexágono externo, porção cervical polida, topo das roscas em forma de "v", passos das roscas contínuos, espirais anguladas e configuração cilíndrica, apresentou distribuição das tensões na região apical, médio e cervical do implante quando submetida à carga vertical e oblíqua. O Grupo III, implante com hexágono interno, porção cervical polida, topo das roscas em forma cônica, passos das roscas contínuos, espirais anguladas e configuração cilíndrica, apresentou distribuição das tensões nas regiões apical, médio e cervical do implante após aplicação de carga vertical e oblíqua. O Grupo IV, implante com sistema cone morse, ombro cervical inclinado, platô ou barbatanas, topo do platô quadradas, passos do platô descontinuais, e configuração cilíndrica, distribuiu as tensões nas regiões apical, médio e cervical do implante após aplicação de carga vertical e oblíqua. Baseado nos resultados obtidos e dentro da metodologia deste estudo conclui-se que: O grupo I, de configuração cônica concentrou a distribuição das tensões em região apical. Os grupo II, III e IV, de configuração cilíndrica, distribuíram as tensões com intensidade e localização similares nos terços apical médio e cervical. O presente estudo evidenciou haver diferenças na distribuição das cargas de um tipo de implante para outro, levando acreditar que essas diferenças possam ter relação com o desenho das roscas e platô.
Abstract: The meaning of this study was analyze on 4 dental implants brands the influence of its thread design on tensions distribution generated thru photoelastic models, after applying a 7.5N load on vertical and oblique directions. Twelve implants, organized in four groups had been selected: I.) Máster Conect Cônico1 4.3 x 13 mm; II.) Titamax Ti Medular2 3.75 x 13 mm; III.) 4,0 Colosso3 RC x 13mm; IV.) Bicon Uncoated Implant4 3.5 x 11mm, being in each group, three dental implants of the same commercial brand. The structural designs of the implants were analyzed with Electronic Microscopy Sweepings. For the tension distribution analysis, eight models had been confectioned in photoelastic resin with 40mm x 10mm base dimensions and 30 mm of length. Two implants of each group had been located and fixed in the interior of photoelastic models. Once verified the absence of tensions in the eight models the analysis were started. Four models of the different groups had received 7.5N load on vertical and four received this same load on oblique direction. By means of the circular polariscope developed in the Dental Materials and Prostheses laboratory the Ribeirão Preto Dental School (USP/RP), it was possible to visualize the tensions fringes generated in the models. Each sequence was photographed, being kept the same focal distance in all the assays. The gotten results had been analyzed by groups. Group I., implants with long internal hexagon and polishing cervical portion, top of rounded off threads, angled steps of continuous threads, spirals and conical configuration, presented tensions concentration on the apical region, when submitted to the vertical and oblique load. Group II, implants with external hexagon, polishing cervical portion, top of threads in form of v, angled steps of continuous threads, spirals and cylindrical configuration, presented tensions distribution on the apical, medial and cervical regions of the dental implants, when submitted to the vertical and oblique load. Group III., implants with internal hexagon, polishing cervical portion, top of threads in conical form, steps of threads continuous, spirals angled and cylindrical configuration, presented tensions distribution on the apical, medial and cervical regions . Group IV, implants with cone morse system, inclined cervical shoulder, square shaped threads, fin or plateau, angled plateau steps discontinuous, and cylindrical configuration, distributed the tensions on the apical, medial and cervical regions after the application of vertical and oblique loads. Based in the results gotten and respecting the limitations of this study it can be concluding that: Group I. with conical configuration, the tension distributions is concentrated on the apical region. Groups II, III and IV, with cylindrical configuration, had distributed the tensions with similar intensity and localization on the apical, medial and cervical regions. In the present study it is evidenced to have differences in the distribution of loads on the dental implants analyzed, being not evident that these differences have relation with the threads design.
Mestrado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Mestre em Clínica Odontológica
Freitas, Júnior Amilcar Chagas [UNESP]. "Plataforma regular versus switching: estudo mecânico por meio de testes laboratoriais de fadiga e análise de elementos finitos em implantes com hexágono externo e interno." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/105554.
Full textConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Proposição. O objetivo do presente trabalho foi avaliar a influência do conceito de plataforma switching na confiabilidade e modo de falha de restaurações unitárias sobre implante com hexágono externo ou interno na região anterior da maxila. Adicionalmente, análises de elementos finitos foram realizadas para avaliar o padrão de distribuição de tensão dentro do complexo pilar-implante e no tecido ósseo peri-implantar. Materiais e Métodos. 84 implantes foram divididos em 4 grupos (n = 21) para realização dos testes de fadiga: SWT-EH e REG-EH (implantes de conexão externa com plataforma switching ou regular, respectivamente); SWT-IH e REG-IH (implantes de conexão interna com plataforma switching ou regular, respectivamente). Análises estatísticas de Weibull foram realizadas considerando as missões de 50.000 ciclos a 210N e 300N. Adicionalmente, foram construídos 4 modelos de elementos finitos considerando as mesmas variáveis para obtenção das tensões equivalentes de von Mises (σvM) no complexo pilar-implante e das máximas tensões principais (σmax) no osso peri-implantar. Resultados. Os valores de Beta para os grupos SWT-EH (1,31), REG-EH (1,55), SWT-IH (1,83) e REG-IH (1,82) indicaram que a fadiga acelerou a falha em todos os grupos. Os valores de confiabilidade calculados para os grupos SWT-EH, REG-EH, SWT-IH e REH-IH foram 0,53 (0,33 - 0,70), 0,93 (0,80 - 0,97), 0,99 (0,93 - 0,99) and 0,99 (0,99 -de tensão estiveram no pilar (SWT-IH = 186 MPa e REG-IH = 88.8 MPa). No osso cortical, os implantes com plataforma switching geraram menor tensão (σmax) tanto para conexão externa (SWT-EH = 49.0 MPa e REG-EH = 56.5 MPa) como para conexão interna (SWT-IH = 37.7 MPa e REG-IH = 45.5 MPa)...
Purpose. The aim of the present study was to evaluate the effect of platform switching concept on reliability and failure modes of anterior single-unit restorations for internal and external hex implants. Additionally, finite element analysis were performed to assess the stress distribution within implant-abutment complex and peri-implant bone. Materials and Methods. 84 implants were divided in 4 groups (n=21) for fatigue tests: REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). Weibull analysis for a mission of 50,000 cycles at 300N was performed. Additionally, 4 three-dimensional finite element models reproducing the characteristics of specimens used in mechanical tests were created to evaluate the equivalent von Mises stress (σvM) within implant-abutment complex and the maximum principal stress (σmax) in the peri-implant bone. Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The calculated reliability for groups SWT-EH, REG-EH, SWT-IH and REH-IH were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), respectively. Failure modes (screw and/or abutment fracture) were similar for regular and switched-platform implants. Within implant-abutment complex, the higher peak of stress (σvM) was observed in fixation screw (SWT-EH = 190 MPa and REG-EH = 160 MPa) for groups with external hex implants; while for groups with internal hex implants was in abutment (SWT-IH = 186 MPa and REG-IH = 88.8 MPa). In the cortical bone... (Complete abstract click electronic access below)
Olate, Morales Sergio Adrian. "Analise histologica e histomorfometrica do reparo osseo perimplantar em cães submetidos a instalação de implantes endosseos com um modelo de carga precoce em dois diferentes desenhos de implantes." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289423.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-13T01:32:19Z (GMT). No. of bitstreams: 1 OlateMorales_SergioAdrian_M.pdf: 2518502 bytes, checksum: 379ec7fb825eca639d7e7c3aa4e052a8 (MD5) Previous issue date: 2009
Resumo: Diferentes protocolos para a reabilitação com prótese implanto assistida têm sido reportados. Deles, é possível que a carga imediata em implantes unitários sejam um dos mais controversos. O objetivo deste estudo foi estabelecer quantitativamente as características de reparo ósseo em implantes submetidos a um modelo de carga precoce. Foi desenvolvido um modelo experimental em cães para a avaliação de dois protocolos de instalação de implantes dentais com dois desenhos diferentes. Foi realizada a exodontia dos pré-molares bilaterais mandibulares dos animais e após de três meses foi realizada a instalação de dois implantes bilateriais. No implante mesial foi realizada a instalação do parafuso cicatrizador de 7 mm (modelo de carga imediata unitária sem contato oclusal) e no implante distal foi instalado o parafuso cobertor (técnica de implante submerso). Cada hemimandíbula recebeu um implante cilíndrico (Neodent Titamax CM®) e um implante cônico (Conexão Conect Ar®) com seu parafuso cicatrizador. Inicialmente os primariamente foram avaliados com microscopia eletrônica de varredura. Os sacrifícios dos animais foram após de três e seis semanas. Os blocos foram descalcificados e processados para análise com histológica descritiva e histomorfométrica. Foi aplicado o teste estatístico t teste para variáveis independentes com nível de significância de 5%. De forma geral, os implantes apresentaram maior formação óssea no nível cervical e menor no nível apical. Os resultados demonstram também maior formação óssea em implantes com o modelo de carga precoce que em aqueles sem carga, com ausência de diferença estatística. Por outra parte, os implantes cônicos apresentaram maior formação óssea que os cilíndricos, também sem significância estatística. Concluiu-se que os implantes com instalação do parafuso cicatrizador, como modelo de restauração imediata sem contato oclusal, apresenta maior quantidade óssea nos vales quando comparados aos implantes não submetidos a carga
Abstract: Several treatment types using prosthesis over implants have been reported, being the singles immediate loading therapy with more controversy. The meaning of the present study is established the characteristics of bone repair in dental implant submitted to immediate loading. It was performed a experimental model using dogs to value two different installations protocols of dental implants. It was done the extraction of the bilateral premolars of the jaw, installing the dental implants after 3 months of healing. The anterior implant was submitted to healing screw install of 7 mm (unitary immediate load model without oclusal contact) and the posterior ones were covered with cove screrw (immerse implant technique). Each hemi-jaw presented one cylindrical (Neodent Titamax CM®) or conical (Conexão Conect Ar®) with with anterior or posterior position, that was evaluated with scanning electron microscopy. The sacrifices were performed on three and six months. The specimens were decalcified and processed to begging its histological evaluation using descriptive and histomorphometric analyses. The statistical test T test was performed using significance index of 5%. In general, dental implants showed more bone formation on cervical region and less on apical area. The results demonstrated more bone formation on the immediate loading types, with no statistical significance. The conical ones presented more bone formation that cylindrical, but without statistical significance. This way it is possible to conclude that implants with immediate installation of healing screw, how immediately load model without oclusal contact (immediately restauration), have more osseous presence when compared to non load implant
Mestrado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Mestre em Clínica Odontológica
Prado, Devanir Silva Vieira 1951. "Avaliação do comportamento mecanico de proteses fixas implantossuportadas por meio da tecnica de extensometria eletrica." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290247.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-13T01:38:34Z (GMT). No. of bitstreams: 1 Prado_DevanirSilvaVieira_M.pdf: 895028 bytes, checksum: fe09fdf9bad8a966f0302b161600791e (MD5) Previous issue date: 2009
Resumo: Muitas vezes, as tensões são causadas por alterações nas adaptações das estruturas protéticas ao implante, além dos desajustes marginais entre as fixações e as reabilitações protéticas. Este trabalho tem como objetivo, avaliar a distribuição de compressão e tração dos pilares protéticos e infra-estrutura metálica fundida em liga de cobalto-cromo, pela técnica de monobloco, simulando uma prótese fixa implantossuportadas sobre 06 implantes com distância de 10 mm entre implantes e com extremo livre (cantilever) bilateral com extensão de 20 mm, colocados através da curvatura da linha oclusal mandibular. Em cada pilar foram colados quatro extensômetros e um em cada cantilever, após o apertamento de todos pilares e a infra-estrutura aos implantes, foi submetido a um ensaio mecânico com cargas compressivas verticais de 150 N, analisando quantitativamente os resultados bem precisos através da extensometria. Os resultados foram obtidos usando os maiores valores de carga axial registrados em cada ponto de força aplicado, registrando deformação para infra-estrutura, pilares e os cantilevers. Com aplicação de carga nos pontos entre os pilares, foi obtido nos pilares mais próximos a aplicação da carga um maior grau de compressão e nos pilares mais distantes, em menor grau de acordo com a distribuição de carga deformação por compressão e ou/ tração. Com aplicação de carga vertical máxima no cantilever, o pilar adjacente foi o mais solicitado por compressão, independente do ponto de aplicação da carga e o último pilar do lado oposto em menor intensidade, também solicitado por compressão, formando um eixo de rotação, no qual os componentes anteriores foram solicitados em regime de tração (alavanca). O carregamento mecânico registrou deformação para a infraestrutura, pilares e cantilever.
Abstract: Frequently, stresses are caused by changes in adaptations of prosthetic structures to the implant besides marginal disajustment between prosthetic fixing and rehabilitations. This study aims to evaluate the distribution of compression and traction of the prosthetic sustainers and the methalic framework melted in cromocobalt alloy, through the monoblock technic simulating a fixed prosthesis implantsupported on 06 implants at the distance of 10mm between each other and with bilateral cantilever extending to 20mm, placed along the mandibular oclusal line curvature, with the extensometry technic. In each abutment there have been placed four strain guages and one in each cantilever, in configuration "Wheatstone Bridge", after all components having been fixed to the framework, it was submitted to a mechanic essay with vertical pressing charges of 150Ncm, checking quantitatively the accurate result through extensometry. Results have been obtained by using the greatest values of axial charge registered in each place of applied force,. On nearest pillars to the charge, It has been obtained a greater degree of compression (fulcrum), what corresponds to the amount of oclusal force applied to the equalizing stress force. And, therefore, the most distant pillars will assimilate a negative deformation ( compression) or a positive deformation (traction, seesaw), proportional to the lever arm.
Mestrado
Protese Dental
Mestre em Clínica Odontológica
Ribeiro, Fernanda Vieira. "Avaliação da regeneração ossea em defeitos peri-implantares de deiscencia tratados com uma abordagem combinada associando celulas derivadas da medula ossea e regeneração ossea guiada : estudo histomorfometrico em cães." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287911.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-14T23:45:21Z (GMT). No. of bitstreams: 1 Ribeiro_FernandaVieira_D.pdf: 8018060 bytes, checksum: 8fc3b530db926d929facce5cfd30fb4e (MD5) Previous issue date: 2009
Resumo: O objetivo deste estudo foi avaliar histometricamente o reparo ósseo em defeitos periimplantares do tipo deiscência, criados cirurgicamente em cães, tratados com a associação de células derivadas da medula óssea (CMs) e regeneração óssea guiada (ROG). A medula óssea foi obtida a partir da crista ilíaca de oito cães beagle adultos machos. Células derivadas da medula óssea (CMs) foram isoladas, cultivadas in vitro e fenotipicamente caracterizadas com relação as suas propriedades osteogênicas. Os mesmos animais foram submetidos à extração bilateral dos primeiros molares e terceiro e quarto pré-molares inferiores. Após três meses, três leitos para a colocação de implantes foram confeccionados em cada lado da mandíbula, deiscências ósseas vestibulares foram criadas e, então, implantes de titânio de superfície usinada foram colocados. As deiscências ósseas foram tratadas aleatoriamente, de acordo com um dos seguintes grupos: 1) ROG+CMs+C: membrana de PTFE-e com reforço de titânio associada às células derivadas da medula óssea semeadas no carreador, 2) ROG+C: membrana de PTFE-e com reforço de titânio associada ao uso do carreador sem células, 3) CMs+C: células derivadas da medula semeadas no carreador, 4) ROG: membrana de PTFE-e com reforço de titânio, 5) C: carreador sem células e 6) Controle: nenhum tratamento. Após três meses, os animais foram sacrificados e os implantes em conjunto com os tecidos adjacentes foram processados laboratorialmente para obtenção de secções não descalcificadas. Os parâmetros avaliados foram: Contato direto osso-implante (CO), Preenchimento ósseo dentro das roscas do implante (PR) e Área de tecido ósseo fora das roscas (AF). In vitro, a caracterização fenotípica demonstrou que células derivadas da medula óssea apresentaram potencial osteogênico identificado pela formação de nódulos minerais e expressão de marcadores ósseos (fosfatase alcalina, sialoproteína óssea e colágeno tipo I). As análises histométricas revelaram que todos os defeitos tratados com membrana (ROG+CMs+C, ROG+C e ROG) demonstraram resultados estatisticamente similares (p>0,05) com relação à área de novo osso formado fora das roscas do implante, apresentando, no entanto, maior quantidade de osso neoformado fora dos limites das roscas, quando comparados aos demais grupos (CMs+C, C e Controle) (p<0,05). Adicionalmente, foi observado que o preenchimento ósseo dentro das roscas foi estatisticamente semelhante entre os grupos que utilizaram membrana (ROG+CMs+C, ROG+C, ROG) e o grupo tratado com células sem barreira (CMs+C) (p>0,05), enquanto todos estes grupos mostraram um preenchimento ósseo significativamente superior ao grupo Controle (p<0,05). Com relação à porcentagem de contato osso-implante, embora os defeitos tratados com membrana (ROG+CMs+C, ROG+C e ROG) tenham apresentado valores estatisticamente maiores quando comparados aos defeitos dos grupos C e Controle (p<0,05), uma tendência para aumento da extensão de contato osso-implante foi observada nos defeitos tratados com células sem a associação da ROG (grupo CMs+C). Dentro dos limites do presente estudo, pôde-se concluir que embora as células derivadas da medula óssea, utilizadas isoladamente, tenham promovido bons resultados em relação à formação óssea dentro das roscas do implante, o seu uso, associado à ROG, não promoveu benefícios adicionais na formação óssea em defeitos peri-implantares de deiscência.
Abstract: The purpose of this investigation was to histometrically evaluate the bone healing in surgically created dehiscence-type defects around titanium implants treated with an association of bone marrow-derived cells (BMCs) and guided bone regeneration (GBR). Bone marrow cells were harvested from eight male adult beagle dogs, cultured in vitro and phenotypically characterized with regard to their osteogenic properties. Following, the same animals were subjected to bilaterally teeth extraction (lower premolars and the first molar) and three months later, three implant sites were drilled in each side of mandible, buccal bone dehiscences were created and titanium dental implants with machined surface were placed. Dehiscences were randomly assigned to one of the following groups: 1) GBR+BMCs+C: PTFE-e barrier placement associated with BMCs into the carrier, 2) GBR+C: PTFE-e barrier placement associated with carrier, 3) GBR: PTFE-e barrier placement, 4) BMCs+C: BMCs into the carrier, 5) C: carrier without cells e 6) Control: no treatment. After 3 months, the animals were sacrificed and the implants in conjunction with adjacent hard tissues were processed for undecalcified sections. Bone-to-implant contact (BIC), bone filling within the limits of implant threads (BF) and new bone area (BA) in a zone lateral to the implant surface were obtained. Results: In vitro, phenotypic characterization demonstrated that BMCs presented osteogenic potential identified by the mineral nodule formation and the expression of bone markers. Histometrically, inter-group analysis demonstrated that all defects treated with GBR (GBR+BMCs+C, GBR+C and GBR) were statistically similar in terms of BA (p>0.05), presenting significantly higher BA as compared with other groups (BMCs+C, C and Control) (p<0.05). With respect the BF, no differences were observed among GBR+BMCs+C, GBR+C, GBR and BMCs+C groups (p>0.05), whereas all these groups showed statistically superior BF as compared to Control group (p<0.05). Additionally, although the percentage of BIC has been significantly higher in the defects treated by barrier membrane (GBR+BMCs+C, GBR+C and GBR) as compared to C and Control groups (p<0.05), a trend towards to a greater extension of BIC has been observed for the defects treated with BMCs+C. Within the limits of this study, it was concluded that although the use of bone marrowderived cells has provided promising outcomes in terms of bone formation within the limits of implant threads, their use, in combination with GBR, has not promoted additional benefits on the bone regeneration in peri-implantar dehiscence type bone defects.
Doutorado
Periodontia
Doutor em Clínica Odontológica
Ricomini, Filho Antônio Pedro 1983. "Avaliação da perda de pre-carga e infiltração bacteriana em sistemas de implantes de encaixe conico e hexagono externo." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288134.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-14T23:43:34Z (GMT). No. of bitstreams: 1 RicominiFilho_AntonioPedro_M.pdf: 1929547 bytes, checksum: 3218196794c582fbd092c07948036e16 (MD5) Previous issue date: 2009
Resumo: A presença de microrganismos na interface implante e pilar é um dos fatores associado ao insucesso de implantes osseointegrados. Sistemas de implantes de encaixe cônico visam precisa adaptação entre o implante e o pilar, entretanto não se sabe o comportamento desses sistemas frente a condições de estresse da cavidade oral quanto à manutenção da pré-carga e capacidade de selamento bacteriano. Assim, o objetivo deste estudo foi avaliar a perda de précarga e a infiltração bacteriana na interface implante e pilar de sistemas de encaixe cônico e hexágono externo, submetidos à ciclagem térmica e fadiga mecânica (CF). Foram utilizados 48 implantes de quatro sistemas de implante-pilar divididos em 8 grupos (n=6): (1) hexágono externo e munhão universal; (2) hexágono externo e munhão universal com CF; (3) cone morse e munhão universal; (4) cone morse e munhão universal com CF; (5) cone morse e munhão universal parafuso passante; (6) cone morse e munhão universal parafuso passante com CF; (7) cônica justaposição e pilar padrão; (8) cônica justaposição e pilar padrão com CF. Os implantes foram fixados em resina epóxica e os pilares acoplados, realizando a pré-carga. Os espécimes (implante-pilar) foram submetidos à ciclagem térmica de 1.000 ciclos a 5°C e 55°C, com permanência de 60 s em cada banho, e à fadiga mecânica de 1,0 milhão de ciclos, 1,0 Hz e 120 N. O ensaio de infiltração bacteriana foi realizado com o microrganismo Streptococcus sanguinis (NCTC 10904). Os espécimes foram imersos em meio Tryptic Soy + Yeast Extract (TY) contendo S. sanguinis e incubados a 37°C e 10% CO2 por 72 h. Os valores de destorque foram registrados e os pilares foram desacoplados. Cone de papel estéril foi esfregado na parte interna do implante, inserido em um tubo contendo meio TY estéril e incubado. A presença de infiltração bacteriana foi avaliada por meio da turbidez do caldo. Implantes e pilares foram avaliados por meio de MEV. Os dados de perda de pré-carga foram submetidos à análise de variância a 2 critérios e ao teste de Tukey. Todos os sistemas apresentaram maiores valores de destorque quando submetidos à CF (p<0,05). O sistema cone morse com munhão universal apresentou os maiores valores de destorque quando comparado aos demais sistemas (p<0,01). Todos os sistemas cônicos apresentaram infiltração bacteriana. Dentro das condições experimentais, o sistema cone morse com munhão universal apresentou os maiores valores de destorque e não foi observado relação entre a perda da précarga e infiltração bacteriana.
Abstract: The presence of microorganisms in the implant and abutment interface is one of the factors associated to the osseointegrated implant failures. Conical junction implant systems have aimed a precise fit between implant and abutment, however, the behavior of these systems it is not known when submitted to the stress environment as found in the oral cavity, related to the preload maintenance and bacterial seal ability. Thus, the aim of this study was to evaluate the preload loss and the bacterial penetration through the implant-abutment interface of conical and external hexagon connection systems, submitted to thermal cycling and mechanical fatigue (TM). Forty eight implants of four different implant-abutment systems were divided in 8 groups (n=6): (1) external hexagon and universal post; (2) external hexagon and universal post with TM; (3) morse taper and universal post; (4) morse taper and universal post with TM; (5) morse taper and universal post two pieces; (6) morse taper and universal post two pieces with TM; (7) locking taper and standard abutment; (8) locking taper and standard abutment with TM. The implants were embedded in epoxy resin and the abutments were connected, setting the preload. The assemblies (implant-abutment) were submitted to thermal cycling of 1.000 cycles at 5°C and 55°C, with a dwell time of 60 s each and to mechanical fatigue, 1.0 million cycles, 1.0 Hz, 120 N. Bacterial penetration assay was performed with Streptococcus sanguinis (NCTC 10904). The assemblies were immersed in Tryptic Soy + Yeast Extract (TY) broth containing S. sanguinis and incubated at 37°C and 10% CO2 for 72 h. Detorque values were recorded and the abutments were disconnected. Sterile paper points were rubbed on the inner part of the implant and inserted in a tube with sterile TY broth and incubated. The presence or absence of bacterial penetration was assessed by the broth turbidity. Implants and abutments were observed by SEM. The preload loss data was analyzed by two-way ANOVA, followed by Tukey test. All the screw systems showed higher detorque values when submitted to TM(p<0,05). The morse taper system with universal post showed the highest detorque values when compared with the other systems (p<0,01). All the conical systems showed bacteria penetration. Within these experimental conditions, the morse taper system with universal post showed the higher detorque values and no relation between the preload loss and the bacterial penetration was observed.
Mestrado
Protese Dental
Mestre em Clínica Odontológica
Lima, Liana Linhares. "Efeito da aplicação intermitente do PTH (1-34) sobre o tecido osseo ao redor de implantes inseridos em ratas expostas ou não a fumaça de cigarro." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287910.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-15T00:47:10Z (GMT). No. of bitstreams: 1 Lima_LianaLinhares_D.pdf: 1779418 bytes, checksum: 5170e97149f324c7dae9d9edd2c763fb (MD5) Previous issue date: 2009
Resumo: O objetivo do presente estudo foi avaliar histometricamente a influência do PTH (1-34) sobre o reparo ósseo e osseointegração de implantes de titânio instalados em tíbias de ratas expostas ou não à inalação da fumaça de cigarro. Foram utilizadas 61 ratas Wistar adultas aleatoriamente divididas em: grupo 1 (n=15) : animais que receberam a aplicação do veículo necessário para a dissolução do hormônio após a instalação do implante; grupo 2 (n=16) : inalação de fumaça de cigarro (IFC) por 60 dias no pré e pós-operatório da colocação do implante; grupo 3 (n = 17): tratamento do grupo 2 associado à injeções subcutâneas de 40 fxg/kg de PTH sintético (1-34) três vezes por semana, após a colocação do implante e grupo 4 (n=13) : injeções subcutâneas de 40 Hg/kg de PTH sintético (1-34) três vezes por semana após a instalação dos implantes. Os animais foram sacrificados sessenta dias após a colocação dos implantes, secções não descalcificadas foram obtidas e avaliadas histometricamente, segundo os seguintes parâmetros: porcentagem de tecido ósseo em contato direto com a superfície do implante (CD), porcentagem de preenchimento ósseo das roscas do implante (AO) e porcentagem de tecido mineralizado numa zona de 500 um, adjacente à superfície do implante (PTM). Os parâmetros foram obtidos separadamente para região cortical e região medular. Não foram detectadas diferenças entre os grupos que receberam aplicação de PTH (1-34) (Grupos 3 e 4) em todos os parâmetros avaliados (p>0,05). Além disso, o PTH promoveu um aumento significativo no CD, AO e PTM em ambas as regiões, mesmo na presença de IFC (p<0.05) (exceto para AO na região cortical). Uma influência negativa da IFC foi observada para o parâmetro CD na região cortical, uma vez que o grupo 2 apresentou os menores valores de CD, seguidos do grupo 1. Resultados semelhantes foram observados para PTM em ambas as regiões analisadas. Dentro dos limites deste estudo pode-se concluir que a aplicação intermitente de PTH (1-34) é capaz de minimizar os impactos negativos da inalação da fumaça de cigarro na osseointegração de implantes de titânio inseridos em tíbias de ratas.
Abstract: The aim of this study was to investigate the synthetic parathyroid hormone, PTH (1-34), can mitigate the effect of cigarette smoke inhalation (CSI) on the bone healing around titanium implants inserted in rats. 61 female Wistar rats were randomly assigned to one of four groups: group l(n = 15): animals that received the application of the necessary vehicle for the dissolution of the hormone after installation of the implant; group 2 (n = 16): cigarette smoke inhalation (CSI) for 60 days preoperatively and sixty days after implant placement group 3(n = 17), treatment group 2, associated with subcutaneous injections of 40 u-g / kg of synthetic PTH (1-34) three times a week after implant placement and group 4 (n = 13): subcutaneous injections of 40 ug / kg of synthetic PTH (1-34) three times a week after placement of implants. The animals were sacrificed sixty days after the placement of implants, not decalcified sections were obtained and evaluated histometrically, according to the following parameters: percentage of bone tissue in direct contact with the implant surface (BIC), percentage of bone filling the threads of the implant (BF) and percentage of mineralized tissue in an area of 500 urn adjacent to the implant surface (BA). The parameters were obtained separately for the cortical and cancellous bone. No differences were found between the groups that received PTH (1-34) (Groups 3 and 4) in all evaluations (p> 0.05). In addition, PTH (1-34) caused a significant increase in BIC, BF and BA in both regions, even in the presence of CSI (p <0.05) (except for BF in the cortical region). A negative influence of the IFC was observed for the parameter BIC in the cortical region, as group 2 had the lowest values of BIC, followed by group 1. Similar results were observed for BA in both regions analyzed. Within the limits of this study can conclude that the intermittent application of PTH (1-34) is able to reversing the negative effects of cigarette smoke inhalation on osseointegration of titanium implants inserted in rats.
Doutorado
Periodontia
Doutor em Clínica Odontológica
Menezes, Alynne Vieira de. "Influencia da inclinação da mandibula em medidas do rebordo alveolar em exames de tomografia computadorizada de feixe conico para implantes." [s.n.], 2010. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290136.
Full textTese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-15T20:48:17Z (GMT). No. of bitstreams: 1 Menezes_AlynneVieirade_D.pdf: 1911461 bytes, checksum: 9eed499fb3fe7db23a7c4de2811423d3 (MD5) Previous issue date: 2010
Resumo: A utilização de implantes dentários para a reabilitação de regiões edêntulas é uma das atividades mais crescentes da Odontologia e a utilização de imagens é um fator essencial para se alcançar o almejado sucesso. Vários métodos de imagem vêm sendo utilizados com esse propósito e a tomografia computadorizada de feixe cônico (TCFC) vem se estabelecendo como um dos métodos promissores nesse sentido, pois se trata de um método confiável, capaz de produzir imagens em tamanho real, sem sobreposição e com dose de radiação menor que a tomografia computadorizada fan beam. Neste trabalho teve-se como objetivo avaliar a influência da posição da mandíbula na realização de medidas da altura e da espessura de sítios implantares em cortes ortorradiais de TCFC. Para tanto, foram utilizadas 10 mandíbulas maceradas, sendo obtidas imagens utilizando-se o tomógrafo de feixe cônico i-CAT. Foi realizada uma única imagem de cada mandíbula e a partir dessa imagem, os cortes ortorradiais foram obtidos considerando-se 3 diferentes posições: 1: base da mandíbula paralela ao plano horizontal (Posição Normal - PN); 2: base com inclinação de +10° (Posição Superior - PS) e 3: com inclinação de -10° (Posição Inferior - PI). A altura e a espessura óssea de cada região foram mensuradas por um único examinador e os dados obtidos nos grupos experimentais (PS e PI) foram comparados com os dados obtidos do grupo controle (PN) usando a análise de variância two-way (a=0,05). Os valores médios de altura e de espessura ósseas não variaram significativamente entre as posições inclinadas (PS e PI) e a posição padrão (PN), o que permite concluir que nas inclinações avaliadas, a direção do plano axial não influenciou nas medidas obtidas
Abstract: Dental implants have became part of routine treatment plans in many cases of edentulous patients and an important part of preimplant examination is provided by images of the existing bone structures in addition to the clinical findings. Several imaging modalities have been used for preimplant assessment and the cone-beam computed tomography may indeed be the next major advancement, since provides clinicians with accurate images of high diagnostic quality with relatively short scanning times and a reported radiation dose lower than fan beam computed tomography. The aim of this present study was to investigate the influence of mandibular inclination on the measured height and width of the cortical bone in reformatted cross-sectional cone beam computed tomography. Ten human dry mandibles were scanned with dental CBCT (i-CAT). It was performed only one scan of any mandible and reformatted cross-sectional scans were obtained at three different positions: (1) parallel to the lower border of the mandible (standard position); (2) with a inclination of +10° (Upper Position) and (3) with a n inclination of -10°(Lower Position). The alveolar bone height and width were measured for one examiner and data subjected to two-way analysis of variance and to compare the means obtained for the experimental groups (UP and LP) with the control group (standard position) (a=0,05). Mean values of bone height and width did not varied significantly between the inclined (UP and LP) and the standard positions. It could be concluded that in the positions analyzed, the direction of the axial planes did not influence the measurements obtained
Doutorado
Radiologia Odontologica
Doutor em Radiologia Odontológica
Olate, Morales Sergio Adrian. "Estudo morfométrico da estrutura óssea crâniofacial visando a reabilitação com prótese facial retida em implantes extrabucais." [s.n.], 2010. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289448.
Full textTese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-16T04:25:57Z (GMT). No. of bitstreams: 1 OlateMorales_SergioAdrian_D.pdf: 2241387 bytes, checksum: f35c455160e70ece3b0c4ef20a1abce8 (MD5) Previous issue date: 2010
Resumo: Os implantes craniofaciais têm sido empregadas para obter retenção e suporte de estruturas protéticas faciais sendo útil em pacientes com seqüelas pelo tratamento do câncer, tumores, trauma ou malformações. O objetivo deste estudo descritivo foi estabelecer a espessura óssea de diferentes regiões do complexo crâniomaxilofacial para definir os melhores locais de instalação de implantes craniofaciais. Em 40 crânios humanos (31 masculinos e 9 femininos), com uma idade de entre 20 e 60 anos, provenientes do Laboratório de Anatomia da FOPUNICAMP foram realizadas tomografias computadorizadas volumétricas cone beam com o sistema I-CAT VISION na área de Radiologia Odontológica da FOPUNICAMP; posteriormente as imagens foram analisadas no software InVesalius 3.0 por dois pesquisadores para realizar a morfometria óssea. As medições foram executadas nas regiões periorbitarias, perinasais, periauriculares e na região do osso zigomático, determinando a distância entre as corticais externa e interna nos sentidos sagitais, axiais e coronais. Foram determinados os valores para cada unidade individual. Nas diferentes regiões avaliadas, na área supraorbitária os valores mínimos foram de 7,92mm ± 1,82mm e na área lateral foram de 7,54mm ± 0,98mm permitindo a instalação de implantes de 5mm ou 6mm; na área do osso zigomático os valores mínimos foram de 10,4mm ± 2,35mm permitindo a inserção de implantes de 8mm. Na área periuricular os valores obtidos na região superior foram de 2,93mm ± 0,55mm e na região inferior foram de 3,1mm ± 0,7mm; já na região do processo mastóide pode ser possível a instalação de implantes de 5mm. Na área perinasal é possível instalar implantes de 4mm ou 5mm. Conclui se que na área crâniomaxilofacial existem regiões de espessura aceitável para instalação de implantes extrabucais, sendo a região auricular superior a que apresenta maiores limitações
Abstract: Craniofacial fixation have been used for retention and support of facial prosthetic devices, useful in patients with sequelae of treatment for cancer, tumors, trauma and congenital or genetic malformations. We conducted a descriptive study to establish the bone thickness in different regions of the cranium complex to define the best locations for craniofacial implants. In 40 human skulls (31 men and 9 female), between 20 to 60 years old, from the Laboratory of Anatomy of FOPUNICAMP were performed tomography computed volumetric cone beam with the ICAT VISION in the area of Dental Radiology of FOP-UNICAMP. Subsequent images were analyzed in InVesalius 3.0 software by two researchers to perform bone morphometry. The measurement were performed in the periorbital, perinasal and periauricular region and the area of zygomatic bone, determining the distance between the internal and external cortical senses in sagittal, axial and coronal views. The values were determined for each individual unit. In the supraorbital area, the minimum values were 7.92 mm ± 1.82 mm and the lateral area were 7.54 mm ± 0.98 mm allowing the installation of 5mm or 6mm length implants, the área of the zygomatic bone minimum values were 10 , 4 mm ± 2.35 mm allowing the insertion of implants of 8 mm. In the periauricular areas the values in the upper region were 2.93mm ± 0.55mm and lower were 3.1mm ± 0.7mm; the region of the mastoid process allowed the installation of 5mm implants. In the perinasal region 4mm or 5mm length implants could be installed. We conclude that in the craniummaxillofacial area there are regions for acceptable thickness for extrabucal implant installation being the superior temporal bone area that show has major limitations
Doutorado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Doutor em Clínica Odontológica
Silva, Cristina Ramos da [UNESP]. "Influência das variáveis morfológicas em modelos fotoelásticos com implantes submetidos à carga axial." Universidade Estadual Paulista (UNESP), 2009. http://hdl.handle.net/11449/97396.
Full textEste trabalho teve como objetivo analisar, em 12 modelos fotoelásticos, com alturas e espessuras diferentes, se a aplicação de uma força axial de 100N sobre os implantes resultaria em alteração na morfologia da reflexão fotoelástica. Na análise fotoelástica, os modelos foram colocados em um Polariscópio para a observação das franjas isocromáticas. A formação destas franjas se fez pela aplicação de uma carga axial de 100N, dirigida ao ponto central do cicatrizador posicionado sobre o implante medindo 10mm x 3,75mm (Conexão, Sistemas de Próteses, Brasil). A tensão resultante de cada modelo fotoelástico foi monitorada e registrada fotograficamente e, subsequentemente vista através do programa gráfico Phothoshop 7.0. Para análise qualitativa, foi mensurada a área abaixo do ápice do implante, envolvendo a faixa verde da franja de segunda ordem de cada modelo através do programa Image Tool. A partir da confrontação do tamanho dessas áreas, definiu-se a performance gerada por cada corpo de prova, frente à carga axial aplicada. Resultados: houve alteração do tamanho da área analisada quando variaram a altura e a espessura dos modelos fotoelásticos. Observamos que quando os modelos foram observados em grupo, o grupo III (altura de 30mm) apresentou menor área. Significância: a morfologia do corpo de prova pode influenciar de forma direta no resultado de pesquisas com modelos fotoelásticos e isto pode levar à 16 interpretações incorretas, portanto, não se pode comparar resultado de corpo de prova com tamanhos e formas diferentes.
This study aimed to analyze in 12 photoelastics models with heights and different thicknesses if the application of an axial force of 100N on implants result in changes in the morphology of photoelastic reflection. For the photoelastic analysis the models were placed in a reflection polariscope for the observation of fringes patterns isochromatics. The formation of these fringes was done by applying an axial load of 100 N, addressed to the central point of healed positioned on the implant measuring 10mm x 3.75 mm (Conexão, Sistemas de Próteses - Brasil). The tension resulting from each photoelastic model was monitored and recorded photographically and subsequently seen through the chart Phothoshop 7.0. For qualitative analysis measured the area below the apex of the implant involving and the fringe of the green belt of the second order of each model through the Image Tool. From the comparison of the size of these areas we define the performance generated by each body of evidence, at the axial load applied. We can see that change in the size of the listening area where several analyzed height and thickness of the models under study. Results: There was variation in the size of the area where several analyzed height and thickness of the photoelastics models. We observed that when the models were observed in group, group III (height 30mm) showed a lower area. Significance: The morphology of the samples can to influence an important role in the direct result of research with photoelastic models and this can lead to 19 incorrect interpretations, so we can not compare the result of samples with different size and shape.
Tonella, Bianca Piccolotto [UNESP]. "Análise fotoelástica da distribuição de tensões em próteses implantossuportadas cimentadas ou parafusadas em implantes de hexágono externo, interno ou cone-morse." Universidade Estadual Paulista (UNESP), 2009. http://hdl.handle.net/11449/97403.
Full textOs aspectos biomecânicos do implante osseointegrado são fundamentalmente diferentes daqueles do dente natural, que é circundado pelo ligamento periodontal. A possibilidade de transferência de sobrecarga ao implante, e deste ao osso, pode exceder o limite fisiológico e provocar falha da reabilitação ou até mesmo a perda da osseointegração. Portanto, é essencial otimizar a distribuição da carga mastigatória através das próteses e destas para os implantes e osso suporte. A avaliação biomecânica da geometria do implante e do sistema de retenção protético torna-se fundamental, visto que os implantes foram desenvolvidos para suportarem forças durante sua função. O estudo das tensões entre as estruturas de suporte e implantes tem sido realizado para prevenir falhas da estrutura protética ou do próprio implante. Assim, nosso trabalho teve como objetivo a realização de dois capítulos, sendo que o primeiro capítulo analisa a distribuição das tensões nos diferentes tipos de implantes, hexágono externo, hexágono interno e cone-morse, em relação aos sistemas de retenção protética, parafusadas ou cimentadas, em próteses parciais fixas implantossuportadas de três elementos. O segundo capítulo aborda a distribuição de tensões nas próteses parciais fixas implantossuportadas unitárias e de três elementos, usando implantes de hexágono externo, interno e cone-morse. Foram construídos modelos fotoelásticos em resina PL-2 (Vishay Measurements Group, Inc Raleigh, N.C. USA), com implantes de 4,00 x 10 mm (Conexão Sistema de Prótese Ltda- São Paulo- SP - Brasil). A saber foram construídos para: 1) próteses parciais fixas implantossuportadas de três elementos com dois implantes, situados na região segundo pré-molar e segundo molar, e 2) modelos com implantes unitários. As próteses foram construídas de forma padronizada...
The biomechanical aspects of an implant are fundamentally different from those of a natural tooth, which is surrounded by a periodontal ligament. The possibility of transferring the overload to the implant, and then to the bone, may exceed the physiological limit and cause failure of rehabilitation or even loss of osseointegration. Therefore, it is essential to optimize the distribution of the chewing load through the prostheses and from them to the implants and support bone. The biomechanical evaluation of the implant’s geometry and prosthetic retained system becomes essential, since the implants were developed to withstand forces during their function. The study of the stress between the structures of support and implants have been done to prevent failures of the prosthesis structure or of the implant. Thus, our work aimed at the achievement of two studies, being the first chapter the analysis of stress distribution on different types of implants: external hexagon, internal hexagon and morse taper, compared to retained prosthesis systems: screwed and cemented in 3-FDP. The second chapter discusses the distribution of stress between dental implant single tooth and 3-FDP, taking into account the different types of connection of the implant. Photoelastic models were built in PL-2 resin (Vishay Measurements Group, Inc Raleigh, NC USA) with 4.00 x 10 mm implants (Conexao Sistema de Protese Ltda- Sao Paulo- SP - Brazil). Models were built for: 1.) fixed partial dentures of three elements with two implants, located in the second pre-molar and on the region of the second molar, and 2) models with dental implants single tooth. The prostheses were constructed in a standardized way with Ni-Cr alloy (Fit Cast-SB Plus - without Beryllium, Talladium do Brasil, Curitiba-PR-Brazil). A circular polariscopy was used and a Universal Testing Machine (EMIC DL-3000) applied axial... (Complete abstract click electronic access below)
Tonella, Bianca Piccolotto. "Análise fotoelástica da distribuição de tensões em próteses implantossuportadas cimentadas ou parafusadas em implantes de hexágono externo, interno ou cone-morse /." Araçatuba : [s.n.], 2009. http://hdl.handle.net/11449/97403.
Full textAbstract: The biomechanical aspects of an implant are fundamentally different from those of a natural tooth, which is surrounded by a periodontal ligament. The possibility of transferring the overload to the implant, and then to the bone, may exceed the physiological limit and cause failure of rehabilitation or even loss of osseointegration. Therefore, it is essential to optimize the distribution of the chewing load through the prostheses and from them to the implants and support bone. The biomechanical evaluation of the implant's geometry and prosthetic retained system becomes essential, since the implants were developed to withstand forces during their function. The study of the stress between the structures of support and implants have been done to prevent failures of the prosthesis structure or of the implant. Thus, our work aimed at the achievement of two studies, being the first chapter the analysis of stress distribution on different types of implants: external hexagon, internal hexagon and morse taper, compared to retained prosthesis systems: screwed and cemented in 3-FDP. The second chapter discusses the distribution of stress between dental implant single tooth and 3-FDP, taking into account the different types of connection of the implant. Photoelastic models were built in PL-2 resin (Vishay Measurements Group, Inc Raleigh, NC USA) with 4.00 x 10 mm implants (Conexao Sistema de Protese Ltda- Sao Paulo- SP - Brazil). Models were built for: 1.) fixed partial dentures of three elements with two implants, located in the second pre-molar and on the region of the second molar, and 2) models with dental implants single tooth. The prostheses were constructed in a standardized way with Ni-Cr alloy (Fit Cast-SB Plus - without Beryllium, Talladium do Brasil, Curitiba-PR-Brazil). A circular polariscopy was used and a Universal Testing Machine (EMIC DL-3000) applied axial... (Complete abstract click electronic access below)
Orientador: Eduardo Piza Pellizzer
Coorientador: Adriana Cristina Zavanelli
Banca: Humberto Gennari Filho
Banca: Rafael Leonardo Xediek Consani
Mestre
Silva, Cristina Ramos da. "Influência das variáveis morfológicas em modelos fotoelásticos com implantes submetidos à carga axial /." Araçatuba : [s.n.], 2009. http://hdl.handle.net/11449/97396.
Full textAbstract: This study aimed to analyze in 12 photoelastics models with heights and different thicknesses if the application of an axial force of 100N on implants result in changes in the morphology of photoelastic reflection. For the photoelastic analysis the models were placed in a reflection polariscope for the observation of fringes patterns isochromatics. The formation of these fringes was done by applying an axial load of 100 N, addressed to the central point of healed positioned on the implant measuring 10mm x 3.75 mm (Conexão, Sistemas de Próteses - Brasil). The tension resulting from each photoelastic model was monitored and recorded photographically and subsequently seen through the chart Phothoshop 7.0. For qualitative analysis measured the area below the apex of the implant involving and the fringe of the green belt of the second order of each model through the Image Tool. From the comparison of the size of these areas we define the performance generated by each body of evidence, at the axial load applied. We can see that change in the size of the listening area where several analyzed height and thickness of the models under study. Results: There was variation in the size of the area where several analyzed height and thickness of the photoelastics models. We observed that when the models were observed in group, group III (height 30mm) showed a lower area. Significance: The morphology of the samples can to influence an important role in the direct result of research with photoelastic models and this can lead to 19 incorrect interpretations, so we can not compare the result of samples with different size and shape.
Orientador: Humberto Gennari Filho
Coorientador: Adriana Cristina Zavanelli
Banca: Marcelo Coelho Goiato
Banca: Fellippo Ramos Verri
Mestre
Santos, Fernanda Henriques dos 1980. "Caracterização de polivinilálcool e polivinilpirrolidona (PVAI/PVP) para reparo de cartilagem articular mandibular." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/263590.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica
Made available in DSpace on 2018-08-18T02:53:41Z (GMT). No. of bitstreams: 1 Santos_FernandaHenriquesdos_M.pdf: 2590038 bytes, checksum: 807936f77ee66231cc661475d6643f25 (MD5) Previous issue date: 2011
Resumo: Na área médica, para se desenvolver um dispositivo que funcione como implante, deve-se utilizar materiais que sejam compatíveis para funções específicas do corpo humano, e esses são classificados como biomateriais. Neste trabalho, foram determinados os parâmetros que serão aplicados ao laser de infravermelho (condutividade térmica do material, densidade do material e comprimento de onda do laser) utilizado na máquina de prototipagem rápida, a qual será usada para a fabricação do implante. Este implante será composto por um biomaterial polimérico a base de Polivinilalcool (PVAl) e, terá como objetivo a substituição da cartilagem articular mandibular. Estudos já avaliaram as propriedades mecânicas de hidrogéis poliméricos de PVAl mostrando sua aplicabilidade como reparadores da cartilagem articular em articulação de quadril, porém a articulação mandibular é submetida à aplicações de cargas superiores havendo a necessidade de melhoria de suas propriedades mecânica. A mistura física de dois ou mais polímeros é denominada blenda polimérica e seu objetivo é aperfeiçoar ou modificar as propriedades dos materiais adequando-as para uma aplicação específica. A literatura relata que PVAl e Polivinilpirrolidona (PVP) são polímeros miscíveis entre si e, quando não reticulados são solúveis em água. O PVP é um polímero amorfo e autolubrificante, e por isso, foi escolhido para melhorar as propriedades mecânicas do PVAl. Blendas nas composições de 90:10 de PVAl e PVP respectivamente, reticuladas via laser infravermelho utilizando concentração de 2,5% de termoiniciador cianovalérico foram caracterizadas via Espectroscopia do Infravermelho Médio, Calorimetria Exploratória Diferencial (DSC), Microscopia Eletrônica de Varredura (MEV) e Extração sol-gel. Através desses experimentos foram determinados os parâmetros do laser para posterior utilização na máquina de prototipagem rápida. Foi possível também realizar a cura do material através do laser de infravermelho. A cura foi confirmada através dos outros ensaios realizados
Abstract: In the medical area to develop a device that functions as an implant, one should use materials that are compatible for specific functions of the human body, and these are classified as biomaterials. In this study, we determined the laser parameters that will be applied to the infrared laser (thermal conductivity, material density and wavelength of the laser) in rapid prototyping machine, which will be used to manufacture the implant. This implant is a polymeric biomaterial based on polyvinylalcool (PVAl) and will aim to replace the articular cartilage of the mandible. Studies have evaluated the mechanical properties of polymeric hydrogels PVAl showing its applicability as repairing articular cartilage in hip joint, but the mandibular joint is subjected to loads greater than applications having the need to improve their mechanical properties. The physical mixture of two or more polymers is called polymer blend and its goal is to improve or modify the properties of materials making them suitable for a specific application. The literature reports that PVAl and PVP polymers are miscible and, when not crosslinked, are soluble in water. PVP is an amorphous polymer and selflubricating, and therefore was chosen to improve the mechanical properties of PVAl. Blends in the compositions of 90:10 PVAl and PVP respectively, crosslinked using infrared concentration of 2.5% termoiniciador cianovaléric were characterized by mid-infrared spectroscopy, Differential Scanning Calorimetry (DSC), Scanning Electron Microscopy (SEM) and sol-gel fraction. Through these experiments were determined laser parameters for subsequent use in rapid prototyping machine. It was also possible to realize the cure of material through the infrared laser. The cure was confirmed by other tests
Mestrado
Materiais e Processos de Fabricação
Mestre em Engenharia Mecânica
O'Sullivan, Dominic. "The effect of implant geometry upon the primary stability of dental implants." Thesis, University of Bristol, 2001. http://hdl.handle.net/1983/339010c1-63ee-4eb9-b03c-b3a2b9b89dbf.
Full textFerreira, Felipe Ramalho. "Idealização e desenvolvimento de um dispositivo para avaliação de resistência da interface implante-intermediário protético por meio de ensaios cíclicos de flexão rotativa." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/25/25135/tde-17082010-155302/.
Full textThe success of a rehabilitation therapy with implant fixtures requires a balance between biological and mechanical factors. The biological factors are innumerable, however the mechanics associate it whit instability of the implant-abutment interface. On the basis of these information, the aim of this study is to create a device which it will be possible to evaluate and to compare the resistance and the stability of the implant-abutment interface whith implants of different connection system and abutments, after the simulated load application, that will be carried through a dynamic assay of rotational fatigue load, also known as rotary bending. For the creation of this device, some procedures on the basis of principles of milling CNC (Computerized Numerical control), electric and physical engineering had been used. The future tests and results, using this device to carry through the fatigue assay, will be published in future works. For the development of the body test to be analyzed in the assay machine, implant fixtures of external hexagon type (Neodent) of 3,75mm of diameter x 11mm of length had been used. In the ending of the development, a trustworthy, resistant and extremely versatile device was gotten; being able itself easily to vary the exerted load and the frequency of rotation, being been thus possible to execute innumerable combinations of fatigue assays. This study demonstrated the possibility and viability of it developing an adequate device to carry through an assay of fatigue, of small dimension (portable) and the significantly inferior cost of what if to buy a proper device for such end.
Santiago, Júnior Joel Ferreira. "Avaliação da influência de diferentes materiais oclusais na confecção de próteses fixas implantossuportadas unitárias com diferentes diâmetros dos implantes osseointegrados : estudo pelo método dos elementos finitos tridimensionais /." Araçatuba : [s.n.], 2010. http://hdl.handle.net/11449/93588.
Full textAbstract: The scientific literature is still scarce about the influence of different veneering materials used in fabricating superstructures for implant-retained fixed prostheses in relation to different implant diameters on stress distribution, and the manifestations and implications in clinical practice were not clarified. The aim of this dissertation was to evaluate the influence of occlusal material for single implant-supported fixed prostheses with different implant diameters. For this study were simulated 8 models, representing a section of the mandibular bone (trabecular and cortical bone) with a single external hexagonal implant (Master Screw, Conexão Sistema de Prótese ltda., Sao Paulo, Brazil) of 3.75 x 10 mm (4 models) and 5.00 mm x10 mm (4 models) with a crown with different occlusal materials: feldspathic porcelain crowns, or acrylic resin or composite resin crown or NiCr alloy. The models were designed using computer-aided design softwares : Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp., Massachusetts, USA). The three-dimensional designs were exported to the finite element program NEI Nastran® 9.0 (Noran Engineering, Inc, USA) for mesh generation, load application and analysis. The results were visualized through von Mises stress maps of each model, to assess individual variations of the stress distribution on the implant and crown; bone results were visualized through maps of maximum principal stress. In axial loading (200 N), cortical bone showed no significant differences in all models,on the trabecular bone the tensile stress increased, with regular implant diameter. For non-axial loads (100 N), the cortical bone, the tensile stress increased significantly on the side common the load application, when it reduced the implant diameter; in the trabecular bone showed seemed stress patterns, although more... (Complete abstract click electronic access below)
Orientador: Eduardo Piza Pellizzer
Coorientador: Fellippo Ramos Verri
Banca: Paulo Sérgio Perri de Carvalho
Banca: Alcides Gonini Júnior
Mestre
Vermeulen, Lisa. "Development of a radiographic dental implant guide for forensic identification using current dental implants." Thesis, Cape Peninsula University of Technology, 2018. http://hdl.handle.net/20.500.11838/2755.
Full textIntroduction: Forensic dentistry plays a key role in identifying human remains that cannot be identified visually or by other means. Studies have shown that in cases of single or multiple deaths, scientific identification of human remains utilising forensic dentistry is often the most successful source of identification. Dental identification of human remains consists of a very complex procedure that makes it necessary during the investigation process to use and compare unique dental identifiers. A reliable and accurate method of identifying human remains is a positive radiological identification between ante-mortem and post-mortem images of dental radiographic images. Even if ante-mortem radiographic images may not be present during the identification process, post-mortem images may include details of dental restorations such as dental implants which cannot be seen during visual examination. The different types of dental implants vary in morphology and in conjunction with the unique appearance of dental anatomy and the placement of custom restorations such as dental implants, it has been found to accurately assist in the identification of human remains. Objectives: To establish a radiographic dental implant guide for ten commonly used dental implant types in the Western Cape, South Africa; and to identify and describe the morphological characteristics of these dental implant types as observed on pantomographs. Methods: The ten commonly used dental implant types were imaged radiographically to create a reference instrument which served as a tool for identifying and comparing different types of dental implants. The morphologies of the different dental implants, specifically the apex, thread and neck, were observed on ante-mortem pantomographs and compared to the appearance of the dental implants on the reference instrument to make a positive match. The straight tube image of all ten dental implant types in the reference instrument was used as the point of reference to positively identify the morphological characteristics of each dental implant type on the pantomographs. The morphological characteristics of the ten commonly used dental implant types used in the Western Cape were described and based on this a radiographic dental implant guide was developed. Results: A total of 384 dental implants were observed on the pantomographs. Of these, 380 dental implants could be positively identified on the pantomographs while 4 dental implants could not. A total of 350 dental implants (91%) were identified as dental implant types listed in the reference instrument while 30 dental implants were identified as a dental implant type not listed in the reference instrument. A total of 208 dental implants (54.2%) could be positively identified using the morphological characteristics namely the apex, thread and neck on the straight tube images of the dental implant type in the reference instrument. The radiographic dental implant guide was developed based on positive identification of the morphological characteristics of the dental implant types. Conclusion: This research study has illustrated that the morphology of dental implants can be used to differentiate between different dental implant types on pantomographs. Each dental implant type had unique morphological characteristics as well as similarities which enabled distinction between the different dental implant types, which facilitated dental implant identification and the development of a radiographic dental implant guide. The radiographic dental implant guide developed as part of this research study, may be useful in the field of forensic dentistry and forensic radiology.
Saliba, Felipe Miguel Pinto. "Proposta de uma metodologia para comparar a capacidade de diferentes parafusos na manutenção da união do componente protético com o implante." Universidade do Estado do Rio de Janeiro, 2006. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=686.
Full textThe occurrences of screws loosening that hold the prosthesis to the implants are concerning reasons for professionals and companies. In fact, companies are trying to minimize this problem by developing and launching screws that, if used, supposedly would reduce the prosthesis failures incidences. This work develops a methodology to achieve a loose tightening torque trial of prosthetic screw, with two defined objectives: (1) to isolate the screw behavior independently from the abutment hexagon; (2) to obtain a loose tightening transfer load, establishing a screw joint movement freedom, as it happens in the mouth, and not only on the prosthetic screw. In order to apply this new methodology, 20 external hexagon implants and 20 abutments without hexagon kept by 20 screws divided in two groups: 10 titanium screws (group 1) and 10 solid lubricated screws TorqTite (group 2). After the abutment fixation by the screw , with a 32 Ncm torque, the reverse torque, instead of being applied to the screw, was applied to the abutment with a key that fitted onto the abutment, making it move in a loose tightening direction, eliminating the preload and screw loosening. Taking the results into consideration, it was possible to see that group 2 had a reverse torque average value higher (48,47 Ncm 5,04) than group 1 (38,62 Ncm 6,43) establishing a significant difference between two screws (p=0,001), even for a small sample, showing the efficiency of the used method.
Floyd, Colette F. "Subcutaneous FSH implants." Connect to this title online, 2007. http://etd.lib.clemson.edu/documents/1193080537/.
Full textLottiaux, Pierre-Marie. "Keratoplasties et implants." Université Louis Pasteur (Strasbourg) (1971-2008), 1992. http://www.theses.fr/1992STR1M104.
Full textTribst, João Paulo Mendes [UNESP]. "Comportamento biomecânico de implantes retos e angulados sobre cargas axiais e não axiais por análise de elementos finitos e extensometria linear." Universidade Estadual Paulista (UNESP), 2017. http://hdl.handle.net/11449/148639.
Full textApproved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-30T19:35:24Z (GMT) No. of bitstreams: 1 tribst_jpm_me_sjc.pdf: 2530158 bytes, checksum: 8e235a2d5347c6969e7816c0f8e75e91 (MD5)
Made available in DSpace on 2017-01-30T19:35:24Z (GMT). No. of bitstreams: 1 tribst_jpm_me_sjc.pdf: 2530158 bytes, checksum: 8e235a2d5347c6969e7816c0f8e75e91 (MD5) Previous issue date: 2017-01-18
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Este trabalho buscou estudar as microdeformações geradas ao redor de implantes de hexágono externo durante carregamentos axiais e não axiais, variando-se a angulação dos implantes, utilizando a análise por elementos finitos e a extensometria linear como ferramentas. Inicialmente modelos 3D de diferentes próteses fixas foram construídos a fim de se permitir uma correlação dos resultados encontrados no modelo simplificado com o modelo anatômico e assim validar a geometria da prótese utilizada no estudo. Após a confirmação dos resultados de tensão similar entre as próteses na região dos implantes e do bloco, o modelo da prótese simplificada foi definida como válida. Em seguida, um modelo de bloco de poliuretano foi criado e duplicado. Implantes com conexão de hexágono externo (HE) foram modelados e em um bloco representados perpendiculares à superfície enquanto que em outro bloco foram colocados com inclinação de 17°. Foram modelados também intermediários do tipo mini pilar cônico retos e angulados conforme a inclinação dos implantes. Por último, foi utilizado o modelo de supraestrutura previamente validada para ambos os grupos, na qual a carga foi incidida. Todos os constituintes foram considerados perfeitamente simétricos, sólidos, isotrópicos. Os modelos receberam cargas de 300 N/cm em pontos axiais e não axiais através do software de análise por elementos finitos para se verificar a tensão máxima principal e as microdeformações. Em seguida, através da análise experimental de extensometria, dois blocos de poliuretano foram confeccionados e receberam três HE cada, bem como, respectivos mini pilares cônicos de acordo com a inclinação dos implantes instalados. Então, uma supraestrutura metálica, idêntica ao modelo computacional foi fundida em NiCr e parafusada sobre os implantes com torque de 10 N/cm. Foram aplicadas cargas de 300 N/cm durante 10 segundos em pontos axiais e não axiais. Para mensurar as microdeformações, foram colados quatro extensômetros na superfície de cada bloco tangenciando os implantes. Os dados obtidos foram analisados estatisticamente através dos testes ANOVA e Tukey (α=5%). Os resultados encontrados pela extensometria mostram que existe diferença significante entre o uso de implantes retos ou inclinados (p<0,005) em uma prótese fixa. Através da correlação das metodologias, pode-se observar que o grupo com implantes inclinados atinge picos de tensão acima do limite fisiológico.
This work aimed to study the microstrains generated around external hexagon implants during axial and non-axial loads, varying the angulation of the implants, using finite element analysis and linear strain gauge as tools. Initially 3D models of different fixed prostheses were constructed in order to allow a correlation of the results found in the simplified model with the anatomical model and thus validate the geometry of the prosthesis used in the study. After confirming the results of similar stress between the prostheses in the implants and the block region, the simplified prosthesis was defined as valid. After, a polyurethane block model was created and duplicated. Implants with external hexagon connection (HE) were modeled and inserted perpendiculary into one block while in another block, were placed with the inclination of 17 °. Straight and angled mini conical abutments were also modeled according to the inclination of the implants. Finally, the supra-structure previously validated for both groups was used, through which the load was affected. All constituents were considered perfectly symmetrical, solid, and isotropic. The models received a load of 300 N / cm in axial and non-axial points through the finite element analysis software, to verify the maximum principal stress and microstrains. Then, through the experimental analysis of strain-gauge, two polyurethane blocks were prepared and received three HE implants each, as well as respective mini tapered pillars according to the inclination of the installed implants. Then, a metallic superstructure, identical to the computational model, was cast in Ni-Cr and screwed onto the implants with torque of 10 N / cm. The load of 300 N / cm was applied for 10 seconds at axial and non-axial points. To measure the microstrains, four extensometers were glued on the surface of each block by tangential implants. The data obtained were statistically analyzed using ANOVA and Tukey tests (α = 5%). S strain-gauge data showed that there is a significant difference between using straight or angled implants (p <0.005) in a fixed prosthesis. And, through the correlation of methodologies it can be observed that the group with angled implants reaches peaks of tension above the physiological limit.
Panza, Leonardo Henrique Vadenal 1982. "Avaliação da manutenção da pre-carga de parafusos de ouro e titanio em proteses implanto-suportadas." [s.n.], 2006. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288245.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-07T21:11:17Z (GMT). No. of bitstreams: 1 Panza_LeonardoHenriqueVadenal_M.pdf: 663328 bytes, checksum: 9c68a1e736e333278ff91bfba5ca2da4 (MD5) Previous issue date: 2006
Resumo: O sucesso da terapia reabilitadora com implantes requer um equilíbrio entre fatores biológicos e mecânicos. Os fatores biológicos são multifatoriais, já os mecânicos associam-se à instabilidade da conexão implante-parafuso-intermediário. Entre os fatores responsáveis pela manutenção da estabilidade desta conexão, a manutenção da pré-carga do parafuso é o mais importante. Com base nestas informações, este estudo buscou avaliar a manutenção da pré-carga de parafusos de ouro, após a aplicação de carga simulada, por meio da realização de ciclagem mecânica do conjunto protético, e também observar a ocorrência de rotação da coroa ou do intermediário protético em relação aos implantes. Para tanto, foram utilizados 40 implantes, 20 com hexágono interno e 20 externo, conectados a intermediários protéticos do tipo Esteticone com angulação de 17° e sem angulação, todos retidos por parafusos de titânio rosqueados a 20N/cm, sobre os quais foram parafusadas coroas confeccionadas em resina acrílica simulando pré-molares superiores humanos com parafusos de ouro apertados a 10N/cm. Cada conjunto foi então submetido ao ensaio de fadiga com aplicação de forças médias de 115 N no sentido do longo eixo do implante por 0.2 s, com uma freqüência de 1 Hz, totalizando um total de 250.000 de ciclos (correspondendo aproximadamente a 3 meses de uso). A manutenção da pré-carga dos parafusos, foi avaliada pelo destorque dos parafusos, após a realização do ensaio de fadiga, com a utilização de um torquímetro digital. Os resultados foram então submetidos à análise de variância a 2 critérios e ao teste de Tuckey, através dos quais foi possível observar que, para o parafuso protético, ocorreu diferença estatisticamente significante entre os tipos de implante, mas sem interação com o tipo de intermediário. No entanto para o parafuso do intermediário ocorreu diferença significativa tanto para o tipo de implante como entre os intermediários, com interação entre os fatores. A análise estatística apontou um desempenho melhor para a manutenção da pré-carga inicial dos parafusos, nos intermediários angulados tanto nos implantes de hexágono interno, quanto nos de hexágono externo. Nenhum dos corpos de prova apresentou rotação de coroa ou intermediário protético quando analisados ao microscópio
Abstract: After osseointegration failures, screw loosening is the most common problem in implant dentistry. However, controversies still exist regarding to the influence of type connection implant to abutment in screw loosing or fracture. This study evaluated pre-tightening maintenance in abutment and prosthetic screws of external and internal implant hexagon with standard and 17° angulated abutments after fatigue testing. Also, the rotational dislodgement was checked using digital measurement microscope. Four subsets (n=10) of implants and abutments were assessed: (G1) internally hexed implant and standard abutment (G2) internally hexed implant and 17° angulated abutment (G3) externally hexed implant and standard abutments (G4) externally hexed implant and 17° angulated abutment. Abutments were retained by titanium screws tightened to 20 N/cm. Acrylic resin crowns were manufactured and were retained over the abutments with gold screws tightened at 10 N/cm, using an electronic torque controller. A vertical line was ascribed across the implant-abutment and crown-abutment interface to identify any rotational displacement. The fatigue tests were performed in a servo-hydraulic machine which delivered forces between 100 and 120 N for 250,000 cycles, through a piston to the crown. The implant-abutment interface were evaluated using a light microscope. Then, screw was removed and detorque value was recorded. Data were statistically analyzed using ANOVA and Tukey test (a=.05) No horizontal displacement of acrylic resin crown and abutments were observed. ANOVA showed significant difference for prosthetic screw between implant types, but without interaction with abutment. However, for abutment screw, there was a significant difference between implant type and abutment. Also, it was observed interaction between implant and abutments types. Internally hexed implants (G1 and G2) and externally hexed implants (G3 and G4) showed significant difference with a better performance for angulated abutment in comparison to standard abutment. Within the limitations of this study it was concluded that pre-tightening maintenance of screw was affected by the type of abutment and the type connection implant used. There was no dislodgement for crown or abutment when standard or pre-angulated abutments were used after 250.000 cycles of simulated loading. Indeed, internal and external hexed connections were effective to avoid rotation of crowns
Mestrado
Protese Dental
Mestre em Clínica Odontológica
Moraes, Paulo Hemerson de 1982. "Analise fotoelástica em diferentes protocolos de reabilitação utilizando implantes dentais em maxilas edêntulas atróficas." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289447.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-17T16:30:04Z (GMT). No. of bitstreams: 1 Moraes_PauloHemersonde_M.pdf: 14156681 bytes, checksum: ca90b60d99caa756d6b1104881f6bf54 (MD5) Previous issue date: 2011
Resumo: Com o avanço da implantodontia, as maxilas edêntulas atróficas que anteriormente eram indicações de enxertos ósseos para viabilizar a reabilitação com implantes dentais, atualmente é possível contornar a maioria destes quadros clínicos sem a necesidade de enxertos ósseos utilizando técnicas como implantes zigomáticos. No entanto, visando a manutenção destes tratamentos aplicados, torna-se essencial o conhecimento do comportamento biomecânico destas modalidades de tratamentos. Diante do exposto, a presente pesquisa apresenta 3 estudos biomecânicos ¿in vitro¿ descritos nos capítulos a seguir. CAPÍTULO I: O objetivo deste estudo foi analisar as tensões mecânicas ao redor dos implantes e ossos adjacentes por meio de análise fotoelástica simulando três combinações de reabilitações com implantes zigomáticos. Cargas oclusais na região do primeiro molar foram simuladas, e a distribuição de tensões sobres os implantes e ossos adjacentes foram examinados. A distribuição das cargas foi observada predominantemente nas regiões de corpo e processo frontal do osso zigomático para ambos os modelos analisados. A distribuição de tensões analisadas pela análise fotoelástica concentrou-se no corpo e processo frontal do osso zigomático. No modelo 1 (2 implantes zigomáticos + 2 implantes convencionais), maiores concentrações foram encontradas ao redor dos implantes e osso adjacente. Diante dos testes realizados, a reabilitação com 2 implantes zigomáticos com 4 implantes convencionais (Modelo 2) são mais favoráveis mecanicamente. CAPÍTULO II: O objetivo deste estudo foi analisar a distribuição de tensões em estruturas craniofaciais e regiões adjacentes aos implantes de dois tipos de reabilitação com conceito All-on- Four utilizando implantes zigomáticos. Os testes fotoelásticos mostraram concentração de carga no corpo e processo frontal do osso zigomático. A partir das análises obtidas, ambos os modelos apresentam satisfatório comportamento mecânico
Abstract: With the advancement of implantology, atrophic edentulous jaws that previously were indications of bone grafts to enable rehabilitation with dental implants, actually is possible to circumvent most of these clinical situations without the need for bone grafts using techniques such as the zygomatic implants. However, for the maintenance of these treatments, becomes essential knowledge of the biomechanical behavior of these treatment modalities. Given the above, this research presents three biomechanical studies in vitro described in the following chapters. CHAPTER I: The aim of this study was to analyze the mechanical stresses around the implants and surrounding bone by photoelastic analysis simulating combinations of three rehabilitations with zygomatic implants. Occlusal loads in first molar region were simulated, and the stress distribution on the implants and surrounding bone were examined. The load distribution was observed predominantly in the body and frontal process of zygomatic bone for both models analyzed. The stress distribution analyzed by photoelastic analysis concentrated on the body and frontal process of zygomatic bone. Model 1 (2 + 2 zygomatic implants conventional implants), higher concentrations were found around the implants and surrounding bone. Before the tests, rehabilitation with two zygomatic implants with conventional implants 4 (Model 2) are better mechanically. CHAPTER II: The aim of this study was to analyze the stress distribution in craniofacial structures and regions adjacent to implants of two types of rehabilitation with All-on-Four concept using zygomatic implants. The photoelastic tests showed load concentration in the body and frontal process of zygomatic bone. From the analysis obtained, both models have satisfactory mechanical properties.
Mestrado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Mestre em Clínica Odontológica
Castro, Gabriela Cassaro de 1986. "Distribuição de tensões ao redor dos implantes em duas condições de desajuste vertical." [s.n.], 2015. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288283.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-26T22:26:53Z (GMT). No. of bitstreams: 1 Castro_GabrielaCassarode_D.pdf: 33391431 bytes, checksum: 639a953ad32049093199c81dd2ea3cb7 (MD5) Previous issue date: 2015
Resumo: Muito se discute sobre importância da passividade, seus efeitos mecânicos e biológicos e a dificuldade em sua obtenção. Devido aos procedimentos inerentes ao processo de confecção da infraestrutura metálica, desde a moldagem à fundição, distorções são incorporadas. Estas tornam-se preocupação biomecânica por gerar tensão no conjunto prótese-implante-osso. Propõe-se avaliar as tensões ao redor dos implantes em infraestruturas de Titânio para prótese total fixa sobre 4 implantes, com diferentes desajustes marginais por meio da fotoelasticidade. Quatro implantes hexágono externo 4,1 x 11,5 mm, foram posicionados sobre uma matriz simulando uma mandíbula edêntula e nomeados da esquerda para direita em A, B, C e D. Aos implantes, foram aparafusados mini-pilares cônicos e entre os pilares e a infraestrutura foram posicionados anéis espaçadores com dimensões conhecidas: para o grupo HE300 (n=5) foi simulado desajuste, respectivamente de A-D: 0 µm, 100 µm, 200 µm e 300 µm, para o grupo HE100 (n=5) apenas desajuste de 100 µm no implante D. A matriz foi duplicada em resina fotoelástica utilizando as infraestruturas como transferente de moldagem. Foram realizadas medições em 6 pontos em cada implante através do teste do parafuso único, em microscópio óptico, para aferir a desadaptação real obtida. Para obter as imagens fotoelásticas padronizadas a infraestrutura foi aparafusada aos pilares e levadas ao polariscópio circular. A tensão cisalhante máxima (Kgf) foi aferida em 7 pontos ao redor de cada implante e comparados quanto as tensões conjuntas em todos os implantes, ao redor de cada implante e na região cervical e apical. Os dados foram tabulados e submetidos à análise estatística pelo teste t de Student, para avaliar a diferença entre as médias de desadaptação e tensão e o teste de correlação de Spearman para verificar a relação entre tensão e desadaptação. A desadaptação média observada foi de 56,96 (±13,23) ?m para o grupo HE100 e de 194,53 (±162,98) ?m para HE300, apresentando diferença entre os grupos. Com relação à tensão, os grupos HE300 e HE100 mostraram-se iguais estatisticamente (p = 0,291). Mas verificou-se correlação positiva entre desadaptação e tensão em HE100 e HE300. Os implantes B, C e D apresentaram maior tensão no grupo HE100 (p < 0,0001) e no grupo HE300, não foi constatado diferença entre os implantes. As tensões foram maiores na cervical do que na região apical em ambos grupos, para HE 100: 36,92 (±9,33) Kgf na região cervical e 17,78 (±4,09) Kgf na região apical; para HE300: 50,37 (±13,20) Kgf na região cervical e para a região apical 21,20 (±3,95) Kgf. O grupo HE300 exibiu significantemente maior valor de tensão na região cervical (p = 0,012). Conclui-se que o desajuste obtido em HE300 foi maior que do grupo HE100 e gerou maior tensão na região cervical. Ao analisar os implantes em conjunto as tensões foram semelhantes estatisticamente. Foi observado correlação entre desajuste e tensão em ambos grupos. Nas duas situações simuladas, a tensão na região cervical foi maior que na apical
Abstract: There is concern over the importance of passivity, its mechanical and biological effects and the difficulty to obtain it. Misalignments are incorporated due to the procedures inherent in the manufacture of the metal frameworks process, from impression to casting. This becomes a biomechanical concern for generating tension in the prosthesis-implant-bone set. It proposes to analyze the stresses around the implants after being bolted with Titanium frameworks for fixed dentures on 4 implants with different marginal misfits through photoelasticity. Four external hex implants, 4.1 x 11.5 mm, were positioned on a matrix simulating an edentulous jaw and named from left to right, A, B, C and D, respectively. Tapered mini-pillars were screwed to the implants and between the pillars and frameworks were positioned spacer rings with known dimensions: For the HE300 (n=5) group there was a simulated misfit, with AD: 0 microns, 100 microns, 200 microns and 300 microns, respectively. For the just misfit HE100 (n=5) group of 100 microns in implant D, the matrix was duplicated in photoelastic resin using the framework as transfer abutment. Measurements were performed in 6 points in each implant, with the single screw test and an optical microscope to measure the real mismatch obtained. For the standardized photoelastic images, infrastructure was bolted to the columns and analyzed at circular polariscope. The maximum shear stress (kgf) was measured at 7 points around each implant and compared as joint stresses in all implants around each implant, cervical and apical region. Data were tabulated and submitted to statistical analysis by Student's t-test, to evaluate the difference between the means of misfit and tension, and the Spearman correlation test to verify the relationship between stress and maladjustment. The average misfit observed was 56.96 (±13.23) microns for the HE100 group, and 194.53 (±162.98) microns for HE300, with differences between groups. Regarding the strain, the HE300 and HE100 groups were statistically equal (p = 0291). Yet there was a positive correlation between misfit and strain into HE100 and HE300. The B, C and D implants presented a higher tension in the HE100 group (p <0.0001) and HE300 group difference was not observed between the implants. Tensions were higher in the cervical than in the apical region in both groups, for HE100: 36.92 (±9.33) and 17.78 (±4.09) kgf in the cervical region, and in the apical region; for HE300: 50.37 (±13.20) kgf in the cervical region, and the apical region 21.20 (±3.95) Kgf. The HE300 group exhibited significantly more tension the cervical region (p = 0.012). It is concluded that the misfit obtained in HE300 was higher than the misfit group HE100 and generated increased tension in the cervical region. However, the analysis of the photoelastic model found tensions to be equal. A direct relationship between misfit and tension was observed in both groups. In both cases simulated, the tension in the cervical region was larger than in the apical
Doutorado
Protese Dental
Doutora em Clínica Odontológica