Dissertations / Theses on the topic 'IEEE 1471'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 41 dissertations / theses for your research on the topic 'IEEE 1471.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Horčic, Michal. "Softwarová architektura." Master's thesis, Vysoká škola ekonomická v Praze, 2011. http://www.nusl.cz/ntk/nusl-85238.
Full textSinclair, Robert, and Charles H. Jones. "APPLYING IEEE 1451 STANDARD TO AATIS." International Foundation for Telemetering, 2001. http://hdl.handle.net/10150/606467.
Full textCurrent legacy acquisition systems such as the Advanced Airborne Test Instrumentation System (AATIS) are custom-built to each individual application with unique sensors and data modules. Replacing, adding, or subtracting sensors requires the system to be removed from service for days, weeks, or even months. This is a result of having to route special wires to each sensor and reprogramming the system with sensor information, calibration data, etc. AR sensor information must be contained in the main system since these systems do not have intelligence at the sensor level. If sensors were to contain information in their own IEEE 1451-compliant transducer electronic data sheet (TEDS), the main system would no longer have to be reprogrammed with this information. This information could then be obtained directly from the sensors when they are inserted into the system. A plug-n-play capability is being added to the system with the development of a standard interface to the system control unit (SCU). This interface, called a Multi-Network Capable Applications Processor (Multi-NCAP), will interface IEEE 1451-compliant smart transducer interface modules (STIMs) to the SCU in the AATIS as well as other legacy systems. With this development, maintenance and new configuration times for the AATIS and other legacy systems will be significantly reduced.
Jesus, Rafael Marcelino de [UNESP]. "MATIW 1451 - monitoramento e acionamento de transdutores inteligentes através da Web (Padrão IEEE 1451)." Universidade Estadual Paulista (UNESP), 2007. http://hdl.handle.net/11449/87251.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Nesta dissertação é apresentada uma aplicação web, dinâmica e interativa, para o controle e monitoramento de transdutores inteligentes conectados em rede de acordo com o padrão IEEE 1451. O ambiente está hospedado em um computador pessoal que desempenha as funções de um servidor web e da parte lógica de um processador com capacidade de operar em rede. O acesso aos transdutores da rede é realizado através de um módulo de interface para transdutores inteligentes, implementado em um dispositivo lógico programável. No desenvolvimento do MATIW 1451 utilizou-se somente plataforma operacional e linguagens de programação de domínio público, abertas e padronizadas como estabelece o comitê gestor do padrão IEEE 1451. O sistema foi testado em uma rede de transdutores contendo um sensor de temperatura e uma ventoinha e em uma rede de distribuição de água, contendo sensores de pressão, vazão e um redutor de pressão.
This paper presents an interactive and dynamic web application to control and monitor smart transducers connected in network according to the IEEE 1451 standart, named MATIW 1451. A personal computer acts as a web server and as the logical part of a NCAP (Network Capable Application Process). The transducers are accessed via a STIM (Smart Transducer Interface Module) implemented by a PLD (Programmable Logic Device). The tools used in the implementation of MATIW 1451 are all in public domain, open as defined by the 1451 committee, including the operating system, languages, libraries and API s. The system was tested in a network of transducers comprised by a temperature sensor and cooler, and also tested in a water distribution kit with pressure and flow sensors, and a pressure reducer.
Jesus, Rafael Marcelino de. "MATIW 1451 - monitoramento e acionamento de transdutores inteligentes através da Web (Padrão IEEE 1451) /." Ilha Solteira : [s.n.], 2007. http://hdl.handle.net/11449/87251.
Full textAbstract: This paper presents an interactive and dynamic web application to control and monitor smart transducers connected in network according to the IEEE 1451 standart, named MATIW 1451. A personal computer acts as a web server and as the logical part of a NCAP (Network Capable Application Process). The transducers are accessed via a STIM (Smart Transducer Interface Module) implemented by a PLD (Programmable Logic Device). The tools used in the implementation of MATIW 1451 are all in public domain, open as defined by the 1451 committee, including the operating system, languages, libraries and APIs. The system was tested in a network of transducers comprised by a temperature sensor and cooler, and also tested in a water distribution kit with pressure and flow sensors, and a pressure reducer.
Orientador: Alexandre César Rodrigues da Silva
Coorientador: Carlos Antônio Alves
Banca: Ailton Akira Shinoda
Banca: Mauro Conti Pereira
Mestre
Cruz, Cristóvão André Antunes. "Support mechanisms for deterministic MAC in IEEE 802.11p." Master's thesis, Universidade de Aveiro, 2015. http://hdl.handle.net/10773/14471.
Full textTransportation systems play an extremely important role in modern society. A huge research e ort has been devoted to this eld in the past few years making them safer cleaner and more e cient, originating the so-called Intelligent Transportation Systems (ITS). While some of the enabling technologies are entering their mature phase, there are still many open problems that must be solved before such systems can be e ectively leveraged. Specifically, the medium access is regarded as being one of the most challenging issues to solve in order to provide dependable wireless communications in vehicular networks [BUSB09]. The standard protocols have been shown to fail in addressing this issue and some possible solutions are being proposed, but despite the di culty of correctly modelling the channel dynamics, most work on MAC protocols for real-time vehicular communications has been performed under simulated environments, using simplistic assumptions that do not necessarily hold in a read environment. The implementation of a deterministic MAC scheme is hampered by the fact that commercial devices do not allow modi cations to the standard MAC mechanism, and the development of a device from scratch to implement one Medium Access Control (MAC) scheme is an extremely laborious endeavour. However, over the last few years, the IT2S platform for vehicular communication has been developed and is now in a stage that allows implementation and testing of new solutions for the vehicular communications environment. It is a exible platform that allows modi cation to be made in any layer of the communication stack and therefore suited to be adapted for the implementation of new MAC schemes. This work presents an overview of MAC mechanisms capable of providing deterministic real-time access and assesses the features a communications device must include in order to allow the implementation of these mechanisms. It then proposes an implementation of such as device based on the existing IT2S plaform. A exible solution was obtained that allows all the studied MAC schemes to be implemented purely in software, with no modi cations required to the hardware mechanisms, lowering the needed amount of skills required to perform a working implementation of a novel MAC scheme. The performance of the solution was also found to be appropriate for the required uses. It is now possible to create test beds for new MAC schemes and perform more concrete and accurate analysis of their performance.
Os meios de transporte têm um papel preponderante na sociedade moderna. Muito esforço de investigação tem sido dedicada e este campo nos últimos anos, com vista a tornar estes meios mais limpos, seguros e eficientes, originado os chamados Sistemas de Transporte Inteligentes (ITS). Enquanto algumas das tecnologias base estão já prontas a ser utilizadas, ainda existem problemas a ser resolvidos antes de se poder utilizar todo o potencial destes sistemas. Um problema específico, o acesso ao meio, é atualmente considerado um dos mais desa antes em termos de investigação e que detém ainda uma quantidade interessante de problemas a ser resolvidos para que se possa depender de comunicações sem fios em ambientes veiculares. Estudos provaram que os protocolos standard nãoo resolvem este problema e têm sido propostas soluções, Mas apesar da dificuldade de modelar corretamente a dinâmica do canal, a maior parte das análises tem sido realizada em ambientes de simulação, com assunçõess simplistas que não correspondem necessariamente ao ambiente real. A implementação de um mecanismo de acesso ao meio determinístico é dificultada pelo facto de que os dispositivos comerciais não permitem modificações aos mecanismos standard e o desenvolvimento de um dispositivo de raiz que implemente o mecanismo proposto ser extremamente trabalhoso. No entanto,ao longo dos últimos anos tem sido desenvolvida a plataforma de comunicações veiculares IT2S, que atingiu agora uma fase que permite a sua utilização para implementar e testar novas soluções para ambientes veiculares. Trata-se de uma plataforma flexível que permite a realização de modificações em qualquer camada da pilha protocolar, portanto passível de ser adaptada para a implementação de novos mecanismos de acesso ao meio. Este trabalho apresenta uma perspetiva alargada dos mecanismos de acesso ao meio determinísticos propostos na literatura e estuda quais as características necessárias que um dispositivo de comunicação precisa fornecer para os poder implementar. Segue-se então uma proposta de implementação de um tal dispositivo, baseada na plataforma IT2S. Foi possível obter uma solução flexível o suficiente para implementar todos os mecanismos estudados recorrendo apenas a software, sem necessidade de alterações ao hardware, baixando a fasquia da dificuldade na criação de uma implementação prática de um mecanismo de acesso ao meio. A solução foi testada e a desempenho considerada adequada para as possíveis utilizações. É agora possível criar bancadas de teste para novos mecanismos de acesso ao meio e executar análises mais concretas e precisas da sua desempenho.
Eccles, Lee H., and Charles H. Jones. "IEEE P1451.0 CORE TEDS AND COMMON COMMAND SET." International Foundation for Telemetering, 2004. http://hdl.handle.net/10150/605792.
Full textThe Technical Committee 9 (TC-9) of the Institute of Electrical and Electronics Engineers (IEEE) Instrument and Measurement Society wants to ensure that all members of the IEEE 1451 family of standards conform to a common set of basic functionality and have, at some level, a common interface. To this end, the IEEE p1451.0 working group has been chartered to prepare an overarching standard that will define the operation of the other members of the family while still leaving the physical interface up to the various other standards working groups. The IEEE p1451.0 will define the general functionality required of an IEEE 1451 transducer, a common command set that is appropriate to all family members, and the core set of transducer electronic data sheets (TEDS). This paper gives a brief overview of the overall functionality and follows that with a description of the commands and the TEDS.
Smith, Conroy. "An admission control scheme for IEEE 802.11e wireless local area networks." Master's thesis, University of Cape Town, 2008. http://hdl.handle.net/11427/14701.
Full textRecent times has seen a tremendous increase in the deployment and use of 802.11 Wireless Local Area Networks (WLANs). These networks are easy to deploy and maintain, while providing reasonably high data rates at a low cost. In the paradigm of Next-Generation-Networks (NGNs), WLANs can be seen as an important access network technology to support IP multimedia services. However a traditional WLAN does not provide Quality of Service (QoS) support since it was originally designed for best effort operation. The IEEE 802. 11e standard was introduced to overcome the lack of QoS support for the legacy IEEE 802 .11 WLANs. It enhances the Media Access Control (MAC) layer operations to incorporate service differentiation. However, there is a need to prevent overloading of wireless channels, since the QoS experienced by traffic flows is degraded with heavily loaded channels. An admission control scheme for IEEE 802.11e WLANs would be the best solution to limit the amount of multimedia traffic so that channel overloading can be prevented. Some of the work in the literature proposes admission control solutions to protect the QoS of real-time traffic for IEEE 802.11e Enhanced Distributed Channel Access (EDCA). However, these solutions often under-utilize the resources of the wireless channels. A measurement-aided model-based admission control scheme for IEEE 802.11e EDCA WLANs is proposed to provide reasonable bandwidth guarantees to all existing flows. The admission control scheme makes use of bandwidth estimations that allows the bandwidth guarantees of all the flows that are admitted into the network to be protected. The bandwidth estimations are obtained using a developed analytical model of IEEE 802.11e EDCA channels. The admission control scheme also aims to accept the maximum amount of flows that can be accommodated by the network's resources. Through simulations, the performance of the proposed admission control scheme is evaluated using NS-2. Results show that accurate bandwidth estimations can be obtained when comparing the estimated achievable bandwidth to actual simulated bandwidth. The results also validate that the bandwidth needs of all admitted traffic are always satisfied when the admission control scheme is applied. It was also found that the admission control scheme allows the maximum amount of flows to be admitted into the network, according the network's capacity.
Jones, Charles H. "IEEE 1451 SMART TRANSDUCER STANDARDS: STATUS, GOING WIRELESS, AND PULLING IT ALL TOGETHER." International Foundation for Telemetering, 2004. http://hdl.handle.net/10150/605791.
Full textThere are seven parts of the Institute of Electrical and Electronics Engineers (IEEE) 1451 Smart Transducer family of standards either approved, in work, or in review. These documents are providing a nonproprietary set of standards for the implementation of smart transducers (i.e., sensors and actuators). This paper overviews these standards and their status. In particular, the IEEE P1451.5, which addresses wireless transducers, and the IEEE P1451.0, which will provide a common high level architecture for the entire family, will be discussed. A reference model, which is being used as a focus for the IEEE P1451.0, will be introduced to help show the relation between all the members of the family.
Tani, Fernando Keisuke. "Proposta de desenvolvimento de transdutores inteligentes baseados na norma IEEE 1451 aplicados a redes LonWorks." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/3/3141/tde-09032007-171041/.
Full textThe need for more efficient and cost-effective solutions in the control and automation market drives the increasing demand for systems based on control networks and smart transducers. However, the fragmented nature of the control network market hinders the development of solutions based on such technologies. The IEEE 1451 family of standards tries to solve this problem by specifying a common set of interfaces between the transducers and the control networks, isolating the transducer\'s project from the choice of networks. In this work, a smart transducer based on the IEEE 1451.2 standard (STIM) and its interface module to a LonWorks network (NCAP) were developed. Through the development and evaluation of the prototypes, the applicability of the standard and the concepts involved in the IEEE 1451 were verified. It was confirmed that a smart transducer based on the IEEE 1451.2 standard can be developed with low-cost, off-the-shelf components and software tools, and that it is possible to combine the benefits of the IEEE 1451 with the qualities of the LonWorks system. It was also perceived that the acceptance of the IEEE 1451 in the market is quite low, and that the release of the remaining standards that make up the IEEE 1451 family is essential for its success.
Munoz, Ramon J., and Robert J. Guice. "IEEE 802.16 Commercial Off The Shelf (COTS) technologies as a compliment to Ship To Objective Maneuver (STOM) communications." Thesis, Monterey, California. Naval Postgraduate School, 2004. http://hdl.handle.net/10945/1417.
Full textThis research evaluates the IEEE 802.16 standards and technologies that are currently being developed in the commercial sector. The robust capability of this standard lends itself potentially to numerous military applications. This research explores how this technology might address the shortcomings of existing military radio and data systems; specifically, with respect to the issues surrounding the Ship to Objective Maneuver (STOM) communications. The intent of this research is to provide recommendations on the necessary 'adapt from COTS' changes for this technology to address STOM networking requirements. This research includes discussions on the military requirements for an IEEE 802.16 adapted waveform. The requirements are for the IEEE 802.16 'adapt from COTS' are derived from researched on the Concept of Employment for STOM operations and the specification of the Joint Tactical Radio Systems (JTRS) Wideband Networking Waveform (WNW). These discussions offer an illustration of the complex networking demands the COTS adapted systems would need to address. Through detailed exploration of the current IEEE 802.16 standards and implementation testing with pre-standard IEEE 802.16a equipment, we were able to make recommendations on the COTS adaptations necessary to make IEEE 802.16 suitable as a complimentary technology within the STOM scenario.
Captain, United States Marine Corps
Sinclair, Robert, Russell Beech, Kevin Jones, Scott Mundon, and Charles H. Jones. "LEGACY SYSTEMS’ SENSORS BECOME PLUG-N-PLAY WITH IEEE P1451.3 TEDS." International Foundation for Telemetering, 2002. http://hdl.handle.net/10150/605608.
Full textReplacing and maintaining sensors in existing legacy systems is costly and time consuming since no information beyond voltage or current is supplied by these sensors. When a sensor is replaced or added, information for that sensor has to be incorporated by the software programmer into the main system software – a costly and time-consuming process. A method has been developed to give these old sensors the intelligence to meet the requirements of the proposed IEEE P1451.3 standard. This is accomplished with no changes to the legacy hardware and a minor, one time change to the legacy main system software.
Rufino, Leonardo Maccari. "Integração do protocolo SIP à norma IEEE 1451 para redes de sensores sem fio." Florianópolis, SC, 2012. http://repositorio.ufsc.br/xmlui/handle/123456789/96189.
Full textMade available in DSpace on 2012-10-26T09:38:57Z (GMT). No. of bitstreams: 1 302647.pdf: 3317702 bytes, checksum: 0b78bafe8cfda4c10b5581993bff11db (MD5)
Redes de sensores sem fio (RSSF) são compostas por dispositivos chamados nós sensores, os quais são capazes de monitorar alguns fenômenos do meio ambiente que os rodeia, tais como informações escalares (temperatura, aceleração) ou multimídia (áudio, vídeo), transformando-os em sinais digitais e comunicando-se com outros nós da rede. A fim de padronizar o acesso e o comportamento das diversas plataformas existentes, a família de padrões IEEE 1451 foi desenvolvida. Esta padronização introduz conceitos interessantes, como a divisão do sistema em duas partes principais, NCAP (Network Capable Application Processor) e TIM (Transducer Interface Module), e a definição dos TEDS (Transducer Electronic Data Sheet). Porém, o padrão não trata eficientemente os requisitos das RSSF atuais, tal como a necessidade dos sensores executarem de forma eficiente e energeticamente consciente, permitindo economizar sua energia, fator crítico em grande parte destes dispositivos. Assim, este trabalho apresenta um novo modo de execução chamado TIM-IM (TIM Initiated Message), o qual permite que TIMs reportem seus dados sempre que houver novas leituras sensoriadas, ao invés de aguardar por polling originado pelo NCAP, evitando permanecer com o módulo de comunicação ligado grande parte do tempo. Adicionalmente, o padrão IEEE 1451 limita-se às redes de sensores que captam informações escalares. Assim, a presente dissertação visa, também, a integração de sensores multimídia à norma, apresentando algumas modificações tanto nos TEDS quanto nas mensagens trafegadas entre NCAP e TIM. A fim de permitir o acesso aos sensores através da rede do usuário, foi utilizado o protocolo SIP (Session Initiation Protocol). SIP vem sendo bastante utilizado atualmente junto à tecnologia VoIP (Voice over Internet Protocol), sendo responsável por estabelecer, modificar e finalizar uma sessão. Devido ao seu tamanho, torna-se inviável seu uso em muitos sistemas embarcados com restrição de recursos. Logo, este trabalho apresenta uma miniaturização do mesmo, alcançada através da eliminação de algumas requisições e campos de cabeçalho (do inglês header fields). Por fim, é apresentada a integração do protocolo SIP ao IEEE 1451. Para isto, foi utilizado o estabelecimento de sessões, assim como o esquema de notificação de presença presente no SIP e a extensão relativa à transferência de mensagens instantâneas. Assim, com a união de ambas as normas, permite-se que sensores sejam acessados por usuários remotos utilizando SIP phones, através da Internet, independentemente de sua localização física.
Wireless sensor networks (WSN) are formed by devices called sensor nodes capable of monitoring some phenomena around them, such as scalar information (temperature, acceleration) or multimedia (audio, video), transforming them into digital signals and communicating with other nodes. In order to standardize the access and behavior of the various platforms available, the IEEE 1451 standards family was developed. This standardization introduces interesting concepts, such as splitting the system into two major parts, NCAP (Network Capable Application Processor) and TIM (Transducer Interface Module), and the definition of TEDS (Transducer Electronic Data Sheet). However, the standard does not address efficiently the requirements of current WSN, such as the need for sensors perform efficiently and energyconscious, saving its energy, which is critical for most of these devices. This work presents a new execution mode called TIM-IM (TIM Initiated Message), which allows TIMs to report its data whenever there are new sensed readings, rather than wait for polling originated by NCAP, avoiding remain with the communication module connected all the time. Additionally, IEEE 1451 is limited to sensor networks that collect scalar information. Thus, this thesis also aims at the integration of multimedia sensors to the standard, presenting some modifications in TEDS and in the messages sent between NCAP and TIM. In order to allow the access to sensors via user#s network, it was used the SIP (Session Initiation Protocol) protocol. SIP has been widely used today by the VoIP (Voice over Internet Protocol) technology and it is responsible to establish, modify and terminate a session. Due to its size, its use is not feasible in many resource-constrained embedded systems. Thus, this work presented a miniaturization of the protocol, achieved through the elimination of some requests and header fields. Finally, it was presented the integration of SIP to IEEE 1451. For this, it was used the session establishment, as well as the presence notification scheme of the SIP protocol and the extension for the transfer of instant messages. Thus, with the union of both standards, sensors can be accessed by remote users using SIP phones through the Internet, regardless of their physical location.
Fernandes, Ronald, Michael Graul, Paul Koola, Mark Garner, and Charles H. Jones. "AN AIRCRAFT T&E METHODOLOGY BASED ON THE IEEE 1451 FAMILY OF STANDARDS." International Foundation for Telemetering, 2005. http://hdl.handle.net/10150/604903.
Full textThis paper describes a methodology for aircraft T&E processes that exploits the advantages of the IEEE 1451 family of standards, including the design, implementation, test, and maintenance of instrumentation systems. The methodology includes the use of handheld and desktop applications that support the design of sensor networks, commissioning of sensors, sensor health monitoring, sensor plug-and-play capability, alarm management, and reports. The methodology incorporates the use of existing instrumentation support systems that have traditionally been used for aircraft T&E processes.
Pereira, Mário Wilson Paiva. "Arquitetura de hardware para monitor de UTI segundo padrão IEEE 1451: uma prova de conceito." reponame:Repositório Institucional da UFC, 2017. http://www.repositorio.ufc.br/handle/riufc/28260.
Full textSubmitted by Renato Vasconcelos (ppgeti@ufc.br) on 2017-11-17T18:30:25Z No. of bitstreams: 1 2017_dis_mwppereira.pdf: 12636405 bytes, checksum: 9101596c0294db74704566e056987670 (MD5)
Rejected by Marlene Sousa (mmarlene@ufc.br), reason: Prezado Mário Wilson: Existe uma orientação para que normalizemos as dissertações e teses da UFC, em suas paginas pré-textuais e lista de referencias, pelas regras da ABNT. Por esse motivo, sugerimos consultar o modelo de template, para ajudar nesta tarefa, disponível em: http://www.biblioteca.ufc.br/educacao-de-usuarios/templates/ Vamos agora as correções sempre de acordo com o template: 1. Na capa inicia-se na margem superior da folha/página com todas as informações centralizadas, em letras maiúsculas, em negrito, fonte tamanho 12 e espaço 1,5 entre linhas. Falta colocar o Centro de Tecnologia no alto da folha 2. Na folha de rosto (que segue a capa) nenhuma informação fica em negrito e o título deve ser todo em maiúsculo. O texto que apresenta a submissão de sua dissertação está transcrito no template. Favor alterar. 3. Na folha de aprovação o tamanho da fonte do titulo está maior que 12, nenhuma informação fica em negrito. Nessa folha não deve constar nem local, nem data. 4. A dedicatória deve iniciar abaixo do meio da folha com recuo de 8 cm da margem esquerda. O texto deve ser apresentado em tamanho 12, justificado, espaço entre linhas 1,5. 5. A palavra AGRADECIMENTOS deve ficar em negrito. 6. Epígrafe: Elemento opcional. Citação, seguida da indicação de autoria, relacionada com o tema do trabalho, expressa em folha/página distinta. Inicia-se abaixo do meio da folha, com recuo de 8 cm da margem esquerda. O texto deve ser digitado em tamanho 12, espaço 1,5 entre linhas, justificado, e entre aspas. 7. Troque a palavra Lista de ilustrações por LISTA DE FIGURAS (use maiúscula e negrito), já que vc optou em utilizar as tabelas separadas. O termo Lista de Ilustrações só deve ser usado quando juntar todas as tabelas em uma só. 8. As LISTAS DE TABELAS, ABREVIATURAS E SÍMBOLOS devem ficar em negrito. 9. No sumário os APÊNDICES e ANEXOS não são numerados, do mesmo modo que as REFERÊNCIAS. 10 Na lista de referencias, retire a informação, que está no final de cada obra citada, do numero de vezes que o autor foi citado em seu trabalho. Quando citar documentos consultados online, colocar autor. título. disponível em:
Submitted by Renato Vasconcelos (ppgeti@ufc.br) on 2017-11-29T12:30:37Z No. of bitstreams: 1 2017_dis_mwppereira.pdf: 13047402 bytes, checksum: f3860047ffbca14a78358f0c384dfb3d (MD5)
Rejected by Marlene Sousa (mmarlene@ufc.br), reason: Prezado Mário Wilson: Vc realizou quase todas as alterações, mas falta ainda, sempre de acordo com template disponível em: http://www.biblioteca.ufc.br/educacao-de-usuarios/templates/ 3. Na folha de aprovação os membros da banca não podem ir para a outra folha. Você pode fazer a opção de dividir um lado do outro. Ex. ________________________________ ________________________________ _________________________________ _______________________________ _________________________________ _______________________________ 10. Na lista de referencias, o título não fica em caixa alta, apenas a primeira letra e siglas se houver. Ex. ANAHP. Observatório 2015. GARCIA, W. L. C. Teds-easy - descricão automática de transducer electronic data sheet MARCONDES, A. Desenvolvimento de protótipo de gravador de TEDS e de etiqueta eletrônica TEDS PRIYA, M. et al. Embedded based wireless ICU monitoring system ROSSI, S. R.; RODRIGUES DA SILVA, A. C.; SANTOS FILHO, T. A. D. IEEE 1451.2- based sensor system with JAVA-TEDS software Tool TESTER, S. N. C. et al. An IEEE 1451 TEDS compiler and serial network compliance tester. Att. Marlene 3366-9620 on 2017-11-29T17:00:56Z (GMT)
Submitted by Renato Vasconcelos (ppgeti@ufc.br) on 2017-12-01T14:14:36Z No. of bitstreams: 1 2017_dis_mwppereira.pdf: 13128245 bytes, checksum: f6b50d91d6917b0407cfdedeba21bf03 (MD5)
Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2017-12-01T16:28:19Z (GMT) No. of bitstreams: 1 2017_dis_mwppereira.pdf: 13128245 bytes, checksum: f6b50d91d6917b0407cfdedeba21bf03 (MD5)
Made available in DSpace on 2017-12-01T16:28:19Z (GMT). No. of bitstreams: 1 2017_dis_mwppereira.pdf: 13128245 bytes, checksum: f6b50d91d6917b0407cfdedeba21bf03 (MD5) Previous issue date: 2017-07-28
This work presents the development of a hardware architecture for ICU monitors, combining design stages of embedded systems, biomedical instrumentation, intelligent sensors and the IEEE 1451 protocol. The method used defines operational requirements, system decomposition into modules, architecture definition and implementation using commercial development platforms. The entire process is based on national and international standards and protocols, seeking to design the system within the constraints of a product and validate the concept through printed circuit board prototypes. The proposed architecture establishes a network of intelligent biomedical sensors, called STIM, controlled by a central node, called NCAP. The use of this architecture provides modular, self-configuring, easy-to-maintain, plug and play sensors with standardized communication and data interface. The work also describes the process of creating electronic data sheets of the STIMs, called TEDS, which contain the operation characteristics of each smart sensor.
Este trabalho apresenta o desenvolvimento de uma arquitetura de hardware para moni- tores de UTI combinando etapas do projeto de sistemas embarcados, instrumentação biomédica, sensores inteligentes e o protocolo IEEE 1451. A metodologia empregada define requisitos operacionais, decomposição do sistema em módulos, definição da arquitetura e implementação utilizando plataformas de desenvolvimento comerciais. Todo o processo é baseado em normas e protocolos de órgãos nacionais e internacionais procurando projetar o sistema dentro das restrições de um produto e validar o conceito por meio de protótipos em placas de circuito impresso. A arquitetura proposta estabelece uma rede de sensores biomédicos inteligentes, denominados STIM, controlados por um elemento cental, denominado NCAP. A utilização desta arquitetura proporciona sensores modulares, autoconfiguráveis, de fácil manutenção, plug and play, com interface de comunicação e dados padronizados. O trabalho também descreve o processo de criação de folhas de dados eletrônicas dos STIMs, denominadas TEDS, que contêm as características de operação de cada sensor inteligente.
Santos, Filho Tércio Alberto dos. "MATIUDE - monitoramento e acesso a transdutores inteligentes (Padrão IEEE 1451) utilizando dispositivos embarcados (celulares e PDA's) /." Ilha Solteira : [s.n.], 2007. http://hdl.handle.net/11449/87053.
Full textAbstract: On this work, an applicatory for mobile devices (cellular and PDA's) called MATIUDE (Monitoring and Access to the Smart Transducers Using the Embedded Devices) was developed for monitoring and access to the smart transducers in compliance with the standard IEEE 1451. The communication between the NCAP and the smart modules is performed though the physical interface standardized TII limiting the system in a total of 255 transducers per module STIM. The tests were carried in a water distribution system in the Hydrology and Hydrometric laboratory on a mockup's farm and ambient temperature monitoring, both developed in the Signal Processing and Digital System Laboratory. The results prove the good working.
Orientador: Alexandre César Rodrigues da Silva
Coorientador: Aparecido Augusto de Carvalho
Banca: Carlos Antonio Alves
Banca: Mauro Conti Pereira
Mestre
Santos, Filho Tércio Alberto dos [UNESP]. "MATIUDE - monitoramento e acesso a transdutores inteligentes (Padrão IEEE 1451) utilizando dispositivos embarcados (celulares e PDA´s)." Universidade Estadual Paulista (UNESP), 2007. http://hdl.handle.net/11449/87053.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Neste trabalho foi desenvolvido um aplicativo para os dispositivos móveis (celulares e PDA´s) chamado MATIUDE (Monitoramento e Acesso aos Transdutores Inteligentes Utilizando os Dispositivos Embarcados) para o monitoramento e acesso aos transdutores inteligentes em conformidade com o padrão IEEE 1451. O sistema realiza a comunicação com o NCAP utilizando a rede ethernet. A comunicação entre o NCAP com os módulos inteligentes é realizada por meio da interface física padronizada TII podendo acoplar num total de 255 transdutores por módulo STIM. Os testes foram realizados em um sistema de distribuição de água no laboratório Hidrologia e Hidrometria, na maquete de uma granja e no monitoramento de temperatura ambiente, porém desenvolvidos no Laboratório de Processamento de Sinais e Sistemas Digitais. Os resultados obtidos comprovam o bom funcionamento do sistema.
On this work, an applicatory for mobile devices (cellular and PDA´s) called MATIUDE (Monitoring and Access to the Smart Transducers Using the Embedded Devices) was developed for monitoring and access to the smart transducers in compliance with the standard IEEE 1451. The communication between the NCAP and the smart modules is performed though the physical interface standardized TII limiting the system in a total of 255 transducers per module STIM. The tests were carried in a water distribution system in the Hydrology and Hydrometric laboratory on a mockup’s farm and ambient temperature monitoring, both developed in the Signal Processing and Digital System Laboratory. The results prove the good working.
Trchalík, Roman. "Síťová architektura a propojování vestavěných systémů." Doctoral thesis, Vysoké učení technické v Brně. Fakulta informačních technologií, 2013. http://www.nusl.cz/ntk/nusl-261223.
Full textNAMBA, Massahide de Oliveira. "Modelagem e Especificação de um Middleware para Redes de Sensores Sem Fio Aplicado à Saúde." Universidade Federal de Goiás, 2011. http://repositorio.bc.ufg.br/tede/handle/tde/518.
Full textSolutions in healthcare are focused on diagnostics, productivity and personal care in this way, theWireless Sensor Networks WSN allow health professionals to monitor people more efficiently. To make integration between WSN and the applications and interfaces that health professionals use more effective its needed a software component that facilitates and mitigates the problems of developing these applications, this component is called middleware. From the perspective of software development, this middleware mainly offers the advantage of focusing the work on the requirements of the software, making the programmer not to worry about the characteristics of hardware and interconnection of devices in the WSN. In the way to facilitate the use of applications in healthcare, this middleware offers some features that are introduced to simplify and ensure the transmission of information in addition to providing reliable use of them. In this work we propose a middleware named Kratos that allows portability and concurrent execution of applications by standardized interfaces to mobile devices, allowing their use in sensor networks applied to health in a transparent way. To evaluate the use of Kratos and its functionality was proposed an application scenario for monitoring electrocardiographic signals (ECG), which will conduct the monitoring and sending alerts to mobile devices from a medical staff. The implementation of the ECG sensor and all the modeling of middleware is in compliance with the IEEE 1451 family of standards.
As soluções na área da saúde focam em diagnósticos, produtividade e cuidados pessoais. Desta forma, as Redes de Sensores Sem Fio RSSF permitem aos profissionais de saúde o monitoramento mais eficiente das pessoas. Para que seja mais eficiente a integração entre as RSSF e as aplicações e interfaces que os profissionais de saúde utilizam, é necessário um componente de software que facilite e mitigue os problemas do desenvolvimento dessas aplicações, a este componente denominamos middleware. Da perspectiva do desenvolvimento de software, este middleware oferece principalmente a vantagem de poder focar o trabalho nas exigências do software, livrando o programador da preocupação com características de hardware e interconexão de dispositivos na RSSF. A fim de facilitar o uso de aplicações na área de saúde, este middleware propõe características que são introduzidas para simplificar e garantir a transmissão de informações, além de proporcionar o uso confiável das mesmas. Nesta dissertação é proposto o middleware Kratos que permite portabilidade e execução concorrente das aplicações por meio de interfaces padronizadas com dispositivos móveis, possibilitando assim o seu uso em redes de sensores aplicadas a saúde de forma transparente. Para validar o uso do Kratos e suas funcionalidades foi proposto um cenário de aplicação para o monitoramento de sinais eletrocardiográficos (ECG), que realiza o monitoramento e envio de alertas para dispositivos móveis de uma equipe médica. A implementação do sensor de ECG bem como toda a modelagem do middleware está em conformidade com a família de padrões IEEE 1451.
Santos, Jos? de Anchieta Gomes dos. "Arquitetura hardware/software de um n?cleo NCAP segundo o padr?o IEEE 1451.1: uma prova de conceito." Universidade Federal do Rio Grande do Norte, 2010. http://repositorio.ufrn.br:8080/jspui/handle/123456789/18681.
Full textOs sensores inteligentes s?o dispositivos que se diferenciam dos sensores comuns por apresentar capacidade de processamento sobre os dados monitorados. Eles tipicamente s?o compostos por uma fonte de alimenta??o, transdutores (sensores e atuadores), mem?ria, processador e transceptor. De acordo com o padr?o IEEE 1451 um sensor inteligente pode ser dividido em m?dulos TIM e NCAP que devem se comunicar atrav?s de uma interface padronizada chamada TII. O m?dulo NCAP ? a parte do sensor inteligente que comporta o processador. Portanto, ele ? o respons?vel por atribuir a caracter?stica de intelig?ncia ao sensor. Existem v?rias abordagens que podem ser utilizadas para o desenvolvimento desse m?dulo, dentre elas se destacam aquelas que utilizam microcontroladores de baixo custo e/ou FPGA. Este trabalho aborda o desenvolvimento de uma arquitetura hardware/software para um m?dulo NCAP segundo o padr?o IEEE 1451.1. A infra-estrutura de hardware ? composta por um driver de interface RS-232, uma mem?ria RAM de 512kB, uma interface TII, o processador embarcado NIOS II e um simulador do m?dulo TIM. Para integra??o dos componentes de hardware ? utilizada ferramenta de integra??o autom?tica SOPC Builder. A infra-estrutura de software ? composta pelo padr?o IEEE 1451.1 e pela aplica??o espec? ca do NCAP que simula o monitoramento de press?o e temperatura em po?os de petr?leo com o objetivo de detectar vazamento. O m?dulo proposto ? embarcado em uma FPGA e para a sua prototipa??o ? usada a placa DE2 da Altera que cont?m a FPGA Cyclone II EP2C35F672C6. O processador embarcado NIOS II ? utilizado para dar suporte ? infra-estrutura de software do NCAP que ? desenvolvido na linguagem C e se baseia no padr?o IEEE 1451.1. A descri??o do comportamento da infra-estrutura de hardware ? feita utilizando a linguagem VHDL
Rossi, Anderson Rodrigo 1981. "Uma nova técnica de comunicação e alimentação de transdutores inteligentes utilizando apenas um fio baseada no padrão IEEE 1451." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/258976.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação
Made available in DSpace on 2018-08-23T02:42:42Z (GMT). No. of bitstreams: 1 Rossi_AndersonRodrigo_M.pdf: 49446456 bytes, checksum: e180d104b943e830a31e17128fa88249 (MD5) Previous issue date: 2013
Resumo: Sabe-se que atualmente, transmissores de loop de corrente, alimentados por um host ou data logger (equipamentos de leitura e/ou armazenamento de dados) são as técnicas mais utilizadas para medição e controle distribuído. Essa transmissão, normalmente, consiste na conexão individual por meio de, no mínimo, um fio, conectando os sensores remotos ao equipamento de leitura de dados. Ressalta-se que, se faz necessária a utilização de um fio terra para o retorno da corrente elétrica juntamente a esse fio de sinal, sendo descrito no texto como "um fio". Consequentemente, com a complexidade envolvida em um processo industrial, tem-se uma grande quantidade de sensores envolvidos, de modo que a ligação de todos os sensores ocasiona uma grande quantidade de fios que convergem para o equipamento de leitura de dados, gerando uma enorme complexidade nas decisões a serem tomadas em relação à instalação e manutenção do sistema. O trabalho tem como objetivo utilizar apenas um fio para a conexão entre vários sensores e atuadores remotos e o equipamento de leitura de dados, a fim de obter, com a diminuição da quantidade de cabeamento, melhoria no controle, precisão nas decisões a serem tomadas, consequentemente, uma maior simplicidade na manutenção e expansão do sistema, além de ser bastante estável às interferências eletromagnéticas, pois o fio recebe a mesma interferência eletromagnética em toda sua extensão e esse efeito se anula permitindo a comunicação entre grandes distâncias. Trata-se de um sistema de interfaceamento de sensores inteligentes a equipamentos de leitura de dados baseado nos padrões IEEE 1451, o qual emprega uma técnica para envio e recebimento de dados e a própria alimentação dos sensores remotos utilizando apenas um fio. O sistema proposto é formado por um NCAP (Network Capable Application Processor), um TII (Transducer Independent Interface), um TIM (Transducers Interface Module), 64 sensores e 64 atuadores caracterizando 128 TransducerChannels. Foi realizado um comparativo com um sistema utilizado pela FEAGRI-UNICAMP (Faculdade de Engenharia Agrícola) para a medição de temperatura no processo de armazenamento com secagem de grãos em silos por aeração forçada para a validação do sistema. Com isso pôde-se verificar as vantagens com relação à rapidez na instalação, facilidade de manutenção, redução de materiais (fios) e confiabilidade no sistema
Abstract: It's known that nowadays, current loop transmitters, fed by a host or a data logger are the most commonly used techniques to distributed measurement and control. Usually this transmission consists of an individual connection through at least a wire pair, connecting the remote sensors to the data logger. It's noted that it's necessary the use of the ground wire to electric current return with this signal wire, it's described at the text as "1 wire". Consequently, with the complexity involved in an industrial process, there is a great amount of involved sensors, in a way that all sensors connection causes a need of a great amount of wires that converge to the data reading equipment, causing a tremendous complexity around the decisions to be taken about the installation and maintenance of the system. This work has as objective using just 1-Wire (a source/communication wire and a common wire) to connect many remote sensors and actuators to the data logger, causing, with the reduction of the cabling amount, a control improvement, accuracy in the decisions to be taken, consequently, a great simplicity in the system maintenance and expansion, besides it's very stable against electromagnetic interference (EMI), because 1-Wire receives the similar EMI and it cancel this effect allowing taking possible to communicate for greater distances. This work discusses the smart sensors interface to data logger based on IEEE1451 standard and it uses a sending/receiving data and sourcing technique using just 1-Wire. The proposed system is formed by a NCAP (Network Capable Application Processor), a TII (Transducer Independent Interface), a TIM (Transducers Interface Module), 64 sensors and 64 actuators, characterizing 128 TransducerChannels. A comparison was made with a system that is used by FEAGRI-UNICAMP (College of Agricultural Engineering - University of Campinas) to measure the temperature at the storage process with grain drying in recipients by forced aeration to validate the system. Thus it can be verified the advantages related to the velocity in the installation, easier maintenance, materials reduction (wires) and reliability on the system
Mestrado
Eletrônica, Microeletrônica e Optoeletrônica
Mestre em Engenharia Elétrica
Rossi, Silvano Renato [UNESP]. "Implementação de um nó IEEE 1451, baseado em ferramentas abertas e padronizadas, para aplicações em ambientes de instrumentação distribuída." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/101976.
Full textUniversidad Nacional de Asuncion
Atualmente, as redes de transdutores inteligentes desempenham um papel de importância vital em sistemas de Medição e Controle Distribuído. Nesse contexto, o Padrão IEEE 1451 para interfaceamento de transdutores inteligentes tem como objetivo simplificar a conectividade de transdutores em ambientes de rede, fornecendo, para tal fim, um conjunto de interfaces padronizadas, aumentando a flexibilidade dos sistemas de instrumentação distribuída. Neste trabalho descreve-se a implementação de um nó de rede em conformidade com o padrão IEEE 1451. O nó foi completamente desenvolvido através do emprego de ferramentas padronizadas e sistemas abertos. O nó é composto por um Processador de Aplicação com Capacidade de Operar em Rede (NCAP), com base no padrão IEEE 1451.1 e um Módulo de Interface para Transdutores Inteligentes (STIM), em conformidade com o padrão IEEE 1451.2. A parte física do NCAP foi implementada através dos recursos de um Computador Pessoal (PC) e de um Dispositivo Lógico Programável (PLD) de uso geral. A parte lógica do NCAP foi desenvolvida através da tecnologia Java. O STIM foi implementado com dispositivos lógicos programáveis versáteis, de uso geral, e sua funcionalidade foi integralmente descrita em linguagem de descrição de hardware. O conjunto NCAP-STIM foi conectado a uma rede de área local, sob o modelo de comunicação cliente-servidor, sendo que várias aplicações clientes podem acessar as informações dos transdutores conectados ao STIM, através da rede, via intermediação do NCAP. O emprego de ferramentas padronizadas e abertas no desenvolvimento total do sistema IEEE 1451 é uma das contribuições mais importantes do presente trabalho. No entanto, há várias contribuições pontuais como: a maneira de descrever as Informações de Transdutores em Formato Eletrônico (TEDS), a implementação... .
Nowadays, smart transducer networks play an essential role in distributed measurement and control systems. In this context, the IEEE 1451 smart transducer interface standards aimed to simplify transducer connectivity, providing a set of common interfaces for connecting transducers in a networked fashion, increasing the flexibility of distributed instrumentation systems. In this work the implementation of a network node according to the IEEE 1451 standard is introduced. The node has been fully developed using open and standardized tools. A Network Capable Application Processor (NCAP) according to the IEEE 1451.1 Standard and a Smart Transducer Interface Module (STIM) comprises the node. The physical part of the NCAP has been implemented using the resources of a Personal Computer (PC) and a general-purpose Programmable Logic Device (PLD). The logical part of the NCAP has been developed using Java technology. The STIM module was implemented with versatile, general-purpose Programmable Logic Devices. STIM functionality has been fully developed in hardware description language. A network node (STIM-NCAP) was connected in a client-server modelbased local area network. Many client applications can access STIM transducers information, through the network with the NCAP as an intermediary. One of the most important contributions of this work is the employment of open and standardized tools for implementing the IEEE 1451 network node. However, there are many specific contributions such as: Transducer Electronic Data Sheet (TEDS’s) description method, programmable logic-based Protocol Manager implementation that allows the use of the parallel port without any modification, the employment of low-cost PLDs for implementing the STIM and the Protocol Manager, and Java-based NCAP software development. Through the implementation of the IEEE Standard, industries... (Complete abstract, click electronic address below).
Rossi, Silvano Renato. "Implementação de um nó IEEE 1451, baseado em ferramentas abertas e padronizadas, para aplicações em ambientes de instrumentação distribuída /." Ilha Solteira : [s.n.], 2005. http://hdl.handle.net/11449/101976.
Full textAbstract: Nowadays, smart transducer networks play an essential role in distributed measurement and control systems. In this context, the IEEE 1451 smart transducer interface standards aimed to simplify transducer connectivity, providing a set of common interfaces for connecting transducers in a networked fashion, increasing the flexibility of distributed instrumentation systems. In this work the implementation of a network node according to the IEEE 1451 standard is introduced. The node has been fully developed using open and standardized tools. A Network Capable Application Processor (NCAP) according to the IEEE 1451.1 Standard and a Smart Transducer Interface Module (STIM) comprises the node. The physical part of the NCAP has been implemented using the resources of a Personal Computer (PC) and a general-purpose Programmable Logic Device (PLD). The logical part of the NCAP has been developed using Java technology. The STIM module was implemented with versatile, general-purpose Programmable Logic Devices. STIM functionality has been fully developed in hardware description language. A network node (STIM-NCAP) was connected in a client-server modelbased local area network. Many client applications can access STIM transducers information, through the network with the NCAP as an intermediary. One of the most important contributions of this work is the employment of open and standardized tools for implementing the IEEE 1451 network node. However, there are many specific contributions such as: Transducer Electronic Data Sheet (TEDS's) description method, programmable logic-based Protocol Manager implementation that allows the use of the parallel port without any modification, the employment of low-cost PLDs for implementing the STIM and the Protocol Manager, and Java-based NCAP software development. Through the implementation of the IEEE Standard, industries... (Complete abstract, click electronic address below).
Orientador: Aparecido Augusto de Carvalho
Coorientador: Alexandre César Rodrigues da Silva
Banca: Onofre Trindade Júnior
Banca: Edward David Moreno Ordonez
Banca: Cláudio Kitano
Banca: Ricardo Tokio Higuti
Doutor
Edenilson, Oliveira Reges José. "Implementação em VHDL de Sensor Inteligente com Módulo CAN e Ampliflicador Sensível à Fase." Universidade Federal de Pernambuco, 2010. https://repositorio.ufpe.br/handle/123456789/5015.
Full textPetróleo Brasileiro S.A.
Neste trabalho são apresentadas a descrição em linguagem VHDL e a implementa ção em FPGA de um amplificador sensível à fase (lock-in) e de um módulo de comunica ção CAN para o desenvolvimento de um sensor inteligente inspirado na família de padrões IEEE 1451. O amplificador sensível à fase é utilizado para detecção e condicionamento de sinais. Sua implementação em formato digital possibilita a utilização de técnicas de processamento digital de sinais. A síntese do amplificador utilizou apenas 6% dos recursos lógicos da FPGA escolhida, possibilitando a implementação de vários amplificadores em paralelo, na mesma FPGA. O módulo CAN implementado é capaz de se comunicar em rede com outros módulos CAN, disponíveis comercialmente. A utilização lógica do módulo CAN implementado foi comparada à do módulo HurriCANe, desenvolvido pela ESA. O funcionamento dos circuitos foi verificado com êxito a partir de simulações e de testes realizados após a implementação em FPGA. A interligação do módulo CAN ao amplificador lock-in foi realizada com sucesso, sendo ocupados apenas 14% dos recursos da FPGA
Batista, Edson Antonio [UNESP]. "Implementação de uma plataforma HW/SW para automação industrial, utilizando hardware reconfigurável com processador NIOS II em conformidade com o padrão IEEE 1451." Universidade Estadual Paulista (UNESP), 2009. http://hdl.handle.net/11449/100282.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
A aplicabilidade da rede de comunicação junto com o avanço tecnológico é constantemente explorada pelos projetistas de automação e controle, pois, estas vertentes podem melhorar o desempenho de um processo industrial. O padrão IEEE 1451, surge em meio a estes desafios, com intuito de homologar conceitos e tecnologias para implementar uma rede de transdutores inteligentes. Neste trabalho desenvolveu-se uma plataforma de hardware/software para ser utilizada na automação industrial, tanto cabeamento como sem fio, de acordo com os padrões IEEE 1451.2 e IEEE 1451.5. Essa plataforma, denominada neste trabalho por plataforma IEEE 1451, é composta por um hardware, o Módulo de Interface para Transdutores (TIM – Transducer Interface Module), e por um software Processador de Aplicação para Rede de Comunicação (NCAP – Network Capable Application Processor). A lógica de controle e as especificações dos transdutores (TEDS – Transducer Electronics Data Sheet) foram inseridas no TIM por meio da programação (linguagem C/C++) do processador NIOS II e o hardware sintetizado em FPGA da família Cyclone II, especificamente na placa de desenvolvimento DE2 da Altera Corporation. A programação do processador NIOS II baseou-se em um template definido neste trabalho como IEEE 1451 que possui funções e bibliotecas específicas para atender às funcionalidades das aplicações e das normas IEEE 1451. O NCAP possui características de um software supervisório e foi desenvolvido com tecnologia Java no ambiente NetBeans IDE (Integrated Development Environment) versão 6.5. Entre as principais funções deste NCAP está a capacidade de enviar e receber os dados através da porta RS232, geração de relatório incluindo a TEDS, interface gráfica dinâmica e identificação de usuários. A plataforma IEEE 1451 foi testada...
Designers usually exploit the fast evolution of technology along with the application of communication networks to improve the performance on industrial processes. The IEEE 1451 standard comes to aid in the development of networks of intelligent transducers, by defining concepts and technologies used in their implementations. This works intends to provide an application consisting of a hardware/software platform to be used in industrial automation, either wireless or not, according to the 1451.2 and 1451.5 IEEE standards. This IEEE 1451 platform is composed by a hardware part, the Transducer Interface Module (TIM), and a software part, the Network Capable Application Processor (NCAP). The control logic and the transducer specifications (TEDS – Transducer Electronics Data Sheet) were inserted in the TIM by programming in C/C++ a NIOS II processor, synthesized in a FPGA of the Cyclone II family, using the DE2 development board from Altera Corporation. The NIOS II programming was based on an IEEE 1451 template, with functions and libraries to implement the functionalities of the IEEE 1451 applications and guidelines. The NCAP software resembles a supervisory system and was developed in Java in the NetBeans integrated development environment, version 6.5. Amongst its main functions are the capabilities of report generation including TEDS, a dynamic graphical interface, user identification and the ability to send and receive data through a RS232 port. This IEEE 1451 platform was tested in the automation of different applications, demonstrating its flexibility and rapid prototyping suited for the development of control systems. Other advantages are the use of an object oriented language in the development of the NCAP software, which facilitates the code reuse, and the use of reconfigurable hardware for the TIM implementation. The results from this work showed that the technology applied... (Complete abstract click electronic access below)
Batista, Edson Antonio. "Implementação de uma plataforma HW/SW para automação industrial, utilizando hardware reconfigurável com processador NIOS II em conformidade com o padrão IEEE 1451 /." Ilha Solteira : [s.n.], 2009. http://hdl.handle.net/11449/100282.
Full textAbstract: Designers usually exploit the fast evolution of technology along with the application of communication networks to improve the performance on industrial processes. The IEEE 1451 standard comes to aid in the development of networks of intelligent transducers, by defining concepts and technologies used in their implementations. This works intends to provide an application consisting of a hardware/software platform to be used in industrial automation, either wireless or not, according to the 1451.2 and 1451.5 IEEE standards. This IEEE 1451 platform is composed by a hardware part, the Transducer Interface Module (TIM), and a software part, the Network Capable Application Processor (NCAP). The control logic and the transducer specifications (TEDS - Transducer Electronics Data Sheet) were inserted in the TIM by programming in C/C++ a NIOS II processor, synthesized in a FPGA of the Cyclone II family, using the DE2 development board from Altera Corporation. The NIOS II programming was based on an IEEE 1451 template, with functions and libraries to implement the functionalities of the IEEE 1451 applications and guidelines. The NCAP software resembles a supervisory system and was developed in Java in the NetBeans integrated development environment, version 6.5. Amongst its main functions are the capabilities of report generation including TEDS, a dynamic graphical interface, user identification and the ability to send and receive data through a RS232 port. This IEEE 1451 platform was tested in the automation of different applications, demonstrating its flexibility and rapid prototyping suited for the development of control systems. Other advantages are the use of an object oriented language in the development of the NCAP software, which facilitates the code reuse, and the use of reconfigurable hardware for the TIM implementation. The results from this work showed that the technology applied... (Complete abstract click electronic access below)
Orientador: Alexandre César Rodrigues da Silva
Coorientador: Aparecido Augusto de Carvalho
Banca: Dionizio Paschoareli Junior
Banca: Luis Carlos Origa de Oliveira
Banca: Eduardo do Valle Simões
Banca: Mauro Conti Pereira
Doutor
Santos, Filho Tércio Alberto dos [UNESP]. "Desenvolvimento de um nó de rede com diferentes interfaces de acordo com o padrão IEEE 1451 utilizando o processador nios II e o sistema operacional embarcado uclinux." Universidade Estadual Paulista (UNESP), 2012. http://hdl.handle.net/11449/100287.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Os sistemas operacionais possuem um papel fundamental nos microcomputadores, realizando o interfaceamento entre os aplicativos e o hardware. Além dos microcomputadores, atualmente, os sistemas operacionais são empregados em ambiente a com arquitetura restrita, como os microcontroladores, denominando-os como sistemas operacionais embarcados. Algumas das aplicações para os sistemas operacionais co embarcados são voltadas para as redes de transdutores inteligentes, realizando o a gerenciamento e controle do sistema em que atua. Neste trabalho apresenta-se o desenvolvimento de um nó de rede denominado NCAP, utilizando o kit DE2 e o sistema o operacional embarcado μClinux para o monitoramento e controle dos TIMs com diferentes interfaces conforme a norma IEEE 1451. O NCAP desenvolvido possui como característica a conexão de diferentes TIMs com recursos de controle e monitoramento com distintas a interfaces de comunicação, com fio (RS-232) e sem fio (ZigBee). Para realização dos testes, foram desenvolvidos 4 TIMs com diferentes características, sendo: 2 STIMs (IEEE P1451.2) e 2 WTIMs (IEEE 1451.5). Os testes foram realizados utilizando uma interface de rede externa, a Ethernet, que, por meio do microcomputador, é possível acessar a página web em um servidor embarcado instalado no nó de rede NCAP. Com isso, é possível realizar o controle e o monitoramento dos transdutores conectados ao TIM independente da interface de comunicação sem fio ou com fio. Além do acesso aos transdutores, e o nó possui características que facilitam o gerenciamento, como: servidor de FTP e acesso remoto. O desenvolvimento do nó de rede embarcado, padronizado pela norma o IEEE 1451, possibilita maior flexibilidade de implantação em locais remotos e facilita a ampliação do sistema sem efetuar grandes modificações na rede. Uma característica importante...
The operating systems have a key role in microcomputers, performing interfacing between applications and the hardware. In addition to computers, currently embedded operating systems are employed in an environment with restricted architecture, such as microcontrollers, terming them as embedded operating systems. Some of the applications for embedded operating systems are geared for smart transducer networks, making the management and control system in which it operates. This work presents the development of a network node denominated NCAP using the DE2 kit and embedded operating system μClinux for monitoring and control of TIMs with different interfaces based on IEEE 1451. The NCAP has developed the characteristic connection of different TIMs with monitoring and control capabilities with different communication interfaces, wired (RS-232) and wireless (ZigBee). The testing, four TIMs were developed with different characteristics, as follows: 2 STIMs (IEEE P1451.2) and two WTIMs (IEEE 1451.5). The tests were performed using an external network interface, Ethernet, that through the PC, you can access the web page in an embedded server installed on the network node NCAP. This makes it possible to perform control and monitoring of transducers connected to the TIM interface regardless of wireless or wired. In addition to access to the transducers, the node has features that facilitate the management, such as FTP server and remote access. The development of embedded network node, standardized by IEEE 1451, allows for greater flexibility of deployment in remote locations and facilitates the expansion of the system without making major changes in the network. An important feature is the dynamic development in relation to the hardware implemented in FPGA with Nios II processor, it is... (Complete abstract click electronic access below)
Santos, Filho Tércio Alberto dos. "Desenvolvimento de um nó de rede com diferentes interfaces de acordo com o padrão IEEE 1451 utilizando o processador nios II e o sistema operacional embarcado uclinux /." Ilha Solteira, 2012. http://hdl.handle.net/11449/100287.
Full textCo-orientador:
Banca: Nobuo Oki
Banca: Aparecido Augusto de Carvalho
Banca: Edson Antonio Batista
Banca: Elnatan Chagas Ferreira
Resumo: Os sistemas operacionais possuem um papel fundamental nos microcomputadores, realizando o interfaceamento entre os aplicativos e o hardware. Além dos microcomputadores, atualmente, os sistemas operacionais são empregados em ambiente a com arquitetura restrita, como os microcontroladores, denominando-os como sistemas operacionais embarcados. Algumas das aplicações para os sistemas operacionais co embarcados são voltadas para as redes de transdutores inteligentes, realizando o a gerenciamento e controle do sistema em que atua. Neste trabalho apresenta-se o desenvolvimento de um nó de rede denominado NCAP, utilizando o kit DE2 e o sistema o operacional embarcado μClinux para o monitoramento e controle dos TIMs com diferentes interfaces conforme a norma IEEE 1451. O NCAP desenvolvido possui como característica a conexão de diferentes TIMs com recursos de controle e monitoramento com distintas a interfaces de comunicação, com fio (RS-232) e sem fio (ZigBee). Para realização dos testes, foram desenvolvidos 4 TIMs com diferentes características, sendo: 2 STIMs (IEEE P1451.2) e 2 WTIMs (IEEE 1451.5). Os testes foram realizados utilizando uma interface de rede externa, a Ethernet, que, por meio do microcomputador, é possível acessar a página web em um servidor embarcado instalado no nó de rede NCAP. Com isso, é possível realizar o controle e o monitoramento dos transdutores conectados ao TIM independente da interface de comunicação sem fio ou com fio. Além do acesso aos transdutores, e o nó possui características que facilitam o gerenciamento, como: servidor de FTP e acesso remoto. O desenvolvimento do nó de rede embarcado, padronizado pela norma o IEEE 1451, possibilita maior flexibilidade de implantação em locais remotos e facilita a ampliação do sistema sem efetuar grandes modificações na rede. Uma característica importante... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The operating systems have a key role in microcomputers, performing interfacing between applications and the hardware. In addition to computers, currently embedded operating systems are employed in an environment with restricted architecture, such as microcontrollers, terming them as embedded operating systems. Some of the applications for embedded operating systems are geared for smart transducer networks, making the management and control system in which it operates. This work presents the development of a network node denominated NCAP using the DE2 kit and embedded operating system μClinux for monitoring and control of TIMs with different interfaces based on IEEE 1451. The NCAP has developed the characteristic connection of different TIMs with monitoring and control capabilities with different communication interfaces, wired (RS-232) and wireless (ZigBee). The testing, four TIMs were developed with different characteristics, as follows: 2 STIMs (IEEE P1451.2) and two WTIMs (IEEE 1451.5). The tests were performed using an external network interface, Ethernet, that through the PC, you can access the web page in an embedded server installed on the network node NCAP. This makes it possible to perform control and monitoring of transducers connected to the TIM interface regardless of wireless or wired. In addition to access to the transducers, the node has features that facilitate the management, such as FTP server and remote access. The development of embedded network node, standardized by IEEE 1451, allows for greater flexibility of deployment in remote locations and facilitates the expansion of the system without making major changes in the network. An important feature is the dynamic development in relation to the hardware implemented in FPGA with Nios II processor, it is... (Complete abstract click electronic access below)
Doutor
Udina, Oliva Sergi. "Smart Chemical Sensors: Concepts and Application." Doctoral thesis, Universitat de Barcelona, 2012. http://hdl.handle.net/10803/84079.
Full textLa tesis introduce conceptos básicos sobre el diseño de sensores químicos inteligentes, en particular presenta los estándares propuestos IEEE-1451 y BS-7986, y elabora una propuesta para el diseño óptimo de dichos sensores químicos inteligentes. Se implementa la propuesta de diseño para una aplicación concreta, el análisis de gas natural. Además de la aplicación de los conceptos sobre sensores químicos inteligentes se pretende además diseñar un analizador compacto, rápido y de bajo coste, para ello se estudia el uso de un microsensor termoeéctrico como sensor principal del analizador. Una vez probada su viabilidad se implementan ambos conceptos (sensores inteligentes y microsensor termoeléctrico) en un prototipo funcional validado en laboratorio. Como resultado se obtiene una propuesta para el diseño de sensores químicos inteligentes basada en estándares, y por otro lado se presenta un nuevo analizador de gas natural, más rápido y compacto que los existentes. Los resultados obtenidos originan diversas publicaciones en revistas así como dos patentes de método y sistema.
FENG, LIN YUEH, and 林岳鋒. "IEEE 1451 smart sensor design and research." Thesis, 2004. http://ndltd.ncl.edu.tw/handle/06112975963698551489.
Full text中華大學
機械與航太工程研究所
92
The purpose of this research is to design an IEEE 1451 smart sensor. This smart sensor is uses a new generation of 8-bit microcontroller unit (MCU) for center controller that is manufactured by Motorola, based on IEEE 1451 standard to build up a smart sensor. The MC68HC908Q family MCU is low-cost, high-performance of 8-bit MCUs, which includes: internal oscillator generator, A/D converter, Digital I/O and Flash memory. These parts are included to reduce external components. Almost MCU can do most of thing except sensor. After implement this MCU the smart sensor module becomes smaller. The data communication is by using RS-232 for information transfer. This new generation of 8-bit MCU is very good for current business requirements of “light, thin, short, small” and low cost. This research is design for some low cost smart sensors, such as temperature sensor, pressure gauge, Accelerometer and Gyroscope. In general, sensors do not have temperature and bias compensation capability. In addition with MCU, this research builds up a Transducer Electronic Data Sheet (TEDS) defined by IEEE 1451 standard, that the sensor can become a precision smart sensor.
Lu, Wei-Han, and 呂瑋翰. "Using IEEE 1451 to Integrate Smart Transducer into ALE Middleware." Thesis, 2011. http://ndltd.ncl.edu.tw/handle/60357943887274991199.
Full textChang, Ning-Chuan, and 張寧娟. "Development of a Middleware for Exploring Practicality of IEEE 1451 Protocol Family." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/86797552960033027019.
Full text國立彰化師範大學
電子工程學系
102
Sensor technology has been widely applied in the application domains nowadays, with the scale expansion, then the sensor network will vigorous development. Because many different sensor network protocols that are incompatible on the system design, expansion, and maintenance are obstacles. Therefore, the IEEE 1451 protocol defines two kind standard function nodes that NCAP and STIM, and uses a unitary system platform to collect transducer data, monitor environment, or control system. In the environment monitoring, in order to achieve the goal that widely monitor environment and share information, use STIM retrieve signals in the partial environment and collects by NCAP spreads to the Internet. In the control system, the STIM and the controlled object build an interface that can exchange information, with construct the control program in NCAP that can immediately and effectively achieve objectives. At the same time, using wide area network (WAN) capacity of NCAP and distributed interactive of other NCAP to expand the scale of whole control system. Before the applications of IEEE 1451 protocol still not mature, for effectively integrate the existent sensor network that practicality applied in IEEE 1451 protocol family. The middleware technique can encapsulate the detail translations between the IEEE1451 protocol and the existent sensor network, through the standard application program interface to hide the detail translations of practicality networks, achieves the goal of unitary IEEE1451 system platform. This paper developed the middleware by two sensor networks that wired CANOpen and wireless Zigbee. Middleware has been achieved and respectively constructed translation interface of CANOpen and Zigbee sensor networks, The functions of IEEE 1451 middleware have request-reply command translation, node discovery, surveillance, failure diagnosis, break detection ,and the transducer data access to create a virtual STIM and sensor network, let NCAP can access sensors information of STIM base on IEEE 1451 protocol. The development achievement of this paper gradually add customized sensor network protocols to extend coverage of the whole sensor network, and concretely implement the goal setting of IEEE 1451 protocol.
Srinivasan, Karthik. "A low cost transmit only wireless sensor based on the IEEE 1451 standard." 2005. http://wwwlib.umi.com/dissertations/fullcit/1428439.
Full textTitle from PDF title page (viewed on Feb. 2, 2006) Available through UMI ProQuest Digital Dissertations. Thesis adviser: Darold Wobschall. Includes bibliographical references.
Venugopal, Nandakumar. "Design of GPS based transducer interface module (TIM) (based on IEEE 1451 standard)." 2006. http://proquest.umi.com/pqdweb?did=1203571621&sid=7&Fmt=2&clientId=39334&RQT=309&VName=PQD.
Full textTitle from PDF title page (viewed on Mar. 15, 2007) Available through UMI ProQuest Digital Dissertations. Thesis adviser: Wobschall, Darold. Includes bibliographical references.
Kuo, YanTing, and 郭彥廷. "On the Design and Implementation of ALE+ Extension to Support IEEE 1451 Transducers." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/04631958311734474256.
Full text逢甲大學
資訊工程學系
103
In this paper, our purpose is to integrate the Application Level Event Plus (ALE+) and IEEE 1451 standard. ALE+ will have better features that ALE+ can operate the transducers based on IEEE 1451 series and sense environmental information. We extend the integration of the transducers; include sensor cycle specification, actuator cycle specification, sensor cycle report and actuator cycle report in the original ALE+. We extend the ALE architecture to the ALE+, and we modify the ALE+ module. This architecture can use in the Internet of Thing (IoT) because it can apply the transducers. But the ALE+ does not much descript the connection between the ALE+ and transducer, so our paper will discuss this problem. We will modify the original ALE+ architecture and the part of connection to the transducers. The modification lets ALE+ communicates to the transducer based on the IEEE 1451 standard, and operate any transducer to sense environmental information. Our extension and modification can let ALE+ complete to using in the IoT.
Pindi, Ntunitangua René. "Desenvolvimento do Módulo de Interface de Transdutor Inteligente Norma ISSO/IEC/IEEE-21451." Master's thesis, 2018. http://hdl.handle.net/10400.6/9930.
Full textNowadays, monitoring, controlling and managing in real time industrial processes is an indispensable task. But more and more, transducer’s networks have conquered their space in this world. The transducer is a key element for these networks and, at the same time, a factor that can result in non-interoperability. This factor is one of the fundamental characteristics of transducer networks. This work consists in the development of a transducer node (TIM) in compliance with the ISO/IEC/IEEE 21451-0 standard, capable of communicating with any node of the network through the NCAP implemented in full compliance with the same standard and communication module based on the IEEE P1452-2 UART standard. The communication between the transducer node and the network node is based on the client-server model. The transducer node was developed in a Texas Instruments Ultra-Lower-Power MSP-EXP430F5529 microcontroller using Code Composer Studio 6.0.
Kong, De Jing, and 孔德景. "A Study and Design the Smart Transducer Interface Module (STIM) with IEEE 1451 Standards." Thesis, 2006. http://ndltd.ncl.edu.tw/handle/41254571798469998985.
Full text聖約翰科技大學
自動化及機電整合研究所
94
The main propose of this thesis is to develop an IEEE 1451 Smart Transducer Interface Module (STIM). To realize this propose, we use an 8-bit microprocessor, PIC 16F877, to implement the STIM, which is connected to the PC by the RS-232 bus, furthermore, to transport the detected data from input sensors to PC. For the data and command display, we use the LabVIEW suit. The users can directly entry the commands via the user graphic interface (GUI) of the LabVIEW. The PIC 16F877 is an 8-bit microprocessor, which was produced by the microchip Company, and a RISC structure. It has the following characteristics: easy to operate, learn, powerful input/output user interface, embedded A/D converter and EEPROM data memory, and digital interface. Thus, we can implement the STIM exploiting only PIC 16F877. Even, the power is turned off, the data of equipments, can be resided in the EEPROM, which is used to implement the Transducer Electronic Data Sheet (TEDS), and the TEDS is a sensor interface to connect the STIM and RS-232, too.
"Proposta de desenvolvimento de transdutores inteligentes baseados na norma IEEE 1451 aplicados a redes LonWorks." Tese, Biblioteca Digital de Teses e Dissertações da USP, 2006. http://www.teses.usp.br/teses/disponiveis/3/3141/tde-09032007-171041/.
Full textCheng, Tung-tzu, and 程銅賜. "Application of EPCglobal Architecture and IEEE 1451 Standards in a Smart Home Security Internet of Things System." Thesis, 2011. http://ndltd.ncl.edu.tw/handle/76126918156176656744.
Full text逢甲大學
資訊電機工程碩士在職專班
99
Due the rapid development of information and communication technology, smart home security system has been quickly moving to digital and networking technology innovation. Since digital data can be stored, processed and transmitted, it makes home security equipments be more functionally sophisticated and remotely controlled. However, digital processing and network communication may have the problems of data exchange and protocol consistence caused by individual manufacture developing its own sensor and security controller using proprietary protocol and data format. It is important to integrate data exchange and communication protocols to effectively perform home security management. In this thesis, we employ IEEE 1451 standards and EPCglobal network architecture as the kernel system of the Internet of Things (IoT). An electronic product code is attached to a smart sensor, such as gas sensor, carbon monoxide sensor, and temperature sensor, to be a unique identification code. The thesis focuses on smart home security scenarios. A security sensing device generates low-level simple security event which is transmitted to the backend IoT system by smart transducer interface module (STIM) including RFID reader. Complex events are defined using event patterns and processed by complex event engine to induce and forecast high-level intelligent events and to reduce home security disasters.
Liu, Wei. "Design of TEDS writer, reader and testing system for transducer interface modules based on the IEEE 1451 standard." 2006. http://proquest.umi.com/pqdweb?did=1136092031&sid=10&Fmt=2&clientId=39334&RQT=309&VName=PQD.
Full textTitle from PDF title page (viewed on Oct. 03, 2006) Available through UMI ProQuest Digital Dissertations. Thesis adviser: Wobschall, Darold C. Includes bibliographical references.
Tseng, Chao-Wen, and 曾昭文. "On the Design of Internet of Things Architecture Based on EPCglobal Extension and IEEE 1451: Identify Layer and Capture Layer." Thesis, 2016. http://ndltd.ncl.edu.tw/handle/apt3sy.
Full text逢甲大學
資訊工程學系
104
Many researchers focus their works on IoT architectural design from different perspectives. How to realize the IoT environment is a significant issue. For building IoT applications, the identification and transducer capability should be brought into consideration simultaneously. GS1 EPCglobal architecture framework is divided into identify, capture, and share layers and defines a collection of standards to support RFID applications. It is not entirely adequate to build IoT applications. IEEE 1451 standard series is a set of transducer standards that defines data exchange formats, communication protocols, and various connection interfaces between sensors/actuators and transducer interface modules. By appending IEEE 1451 transducer capability to the EPCglobal extension framework, a consistent EPC scheme expression for heterogeneous things can be achieved at the identify layer. It is beneficial to put minimum efforts on the extension of capture and share layers. The deployment of IoT applications contains a variety of things that are attached to endpoint devices such as RFID tags, sensors, and actuators to perform identifying things, sensing, and controlling. In the identify layer, we focus on how to resolve the heterogeneous and dynamic characteristic of this variety of things. A uniform expression mechanism based on Electronic Product Coding scheme is introduced. The extended SGTIN and SGXIN approaches are proposed in this dissertation. This mechanism plays a fundamental role in supporting transducer capability. The Application Level Events is extended to collect and process sensor/actuator data at the capture layer. Device cycle, transducer cycle specification, and transducer cycle report are introduced to collect and process transducer data in the capture layer. The extension of ALE middleware module is proposed for explaining the design philosophy and proving the concept. A transducer event is introduced in EPCglobal Information Services. It makes a fundamental for adding transducer capability and share information with the capture and query services of EPCIS. IoT applications are deployed in the field of smart home, building, medical care, manufacture, service, and agriculture. However, these applications cannot exchange the gathered data and analyze for decision making usually. This dissertation proposes a coding mechanism at the identify layer and ALE extension at the capture layer. By cooperating with the layers of EPCglobal extension, an IoT architecture based on international standards for building versatile applications is proposed. The other architecture design issues such as security, fault tolerance, and load balance are not addressed.
Guia, Sabrina Santos. "A Platform to Support the Development of Applications Based on the Segmentation and Labelling Algorithm." Master's thesis, 2015. http://hdl.handle.net/10400.6/5975.
Full textA necessidade do uso de redes de sensores que operem de forma cada vez mais eficiente impulsiona os métodos de investigação destinados à melhoria da gestão de informação. Ao mesmo tempo, a explosão tecnológica que se apodera da nossa vida quotidiana, tem uma influência não só sobre o que é plausível a ser padronizado, mas também na sua possibilidade de execução. Um exemplo disso é a necessidade de intercâmbio de conhecimento do comportamento do sinal do sensor de forma padronizada, bem como de algumas das suas características e parâmetros isolados. A diminuição de dados a serem geridos e transmitidos torna-se claramente útil, em especial, quando há interesse no estudo de características dos sinais, tais como: amplitude, presença de ruido, tendência para valores em estado estacionário, etc., pequenos parâmetros capazes de induzir o comportamento geral do sinal medido. No mundo dos sensores, a inteligência dos mesmos é concentrada no ponto de medição efetuada pelo transdutor. A partir deste ponto, são apresentados três algoritmos. O primeiro é baseado na técnica de procedimento de medição rápida da transformada de Fourier (FFT), enquanto o segundo é baseado na teoria de amostragem compressiva (CS). Por último apresenta-se uma proposta de algoritmo, no domínio do tempo, baseado nos processos de segmentação e rotulagem (S&L) da sobre amostragem de um sinal, também proposto para a definição do novo padrão do IEEE 1451. Sendo que o seu objetivo principal foca-se na gestão de uma quantidade menor de dados, mas na aquisição da mesma quantidade e qualidade de informação. Deste modo, o ideal será que o sinal seja sobre amostrado, por forma a criar redundância entre as amostras vizinhas. Não sendo por isso necessária a segmentação de cada par de amostras, armazenando e transferindo apenas as amostras que forem consideradas portadoras de informação importante. Como resultado do processo de segmentação, são obtidos dois vetores para o armazenamento das amplitudes e índices de tempo das amostras essenciais, e do processo de rotulagem, os segmentos são classificados, segundo o seu comportamento, em oito classes diferentes e armazenados num terceiro vetor. O conjunto com vetores, MCT, forma uma plataforma estruturalmente normalizada de apoio à cooperação de dados sensoriais. A mesma permite, também, assegurar a reconstrução do sinal adquirido. Este último foi implementado e cada função e seus respetivos módulos de operação foram descritos ao pormenor. Além disso, foram também indicados os respetivos parâmetros de entrada e de saída de cada função. Posteriormente, o projeto foi preparado para implantação num microcontrolador, cuja arquitetura é ARM. Resultados experimentais são relatados e expostos, com a finalidade de demonstrar o desempenho do algoritmo proposto, na área de aquisição, análise e processamento de sinais. Após execução do procedimento anteriormente mencionado, a análise de sequência de segmentos revela que o algoritmo possui a capacidade de extrair informações globais, de sinais adquiridos, à semelhança do comportamento de um observador Humano. Além disso, o seu reduzido custo computacional permite a sua incorporação em sensores inteligentes destinados aos mais variados contextos de aplicação, viabilizando a sua execução em tempo real. O documento está dividido em quatro capítulos. No primeiro capítulo é feita uma breve investigação do estado da arte, são apresentadas as considerações teóricas na área de extração de conhecimento a partir da aquisição, análise e processamento de dados. No segundo capítulo são descritos os algoritmos mais conhecidos no que diz respeito à aplicação na área de estudo. No terceiro, são mostradas as ferramentas de software e os dispositivos de hardware aplicados à respetiva implementação e implantação do projeto de programação. No quarto capítulo é realizada a implementação do algoritmo proposto e feita a respetiva implantação do mesmo. As funções integrantes da API são individualmente testadas e os resultados expostos e analisados. No quinto, e último, capítulo são feitas as considerações finais, tiradas as respetivas conclusões e apresentadas as sugestões de trabalho futuro.