Contents
Academic literature on the topic 'Extracción líquido-líquido'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Extracción líquido-líquido.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Extracción líquido-líquido"
Santos, Gabriel, and Ysrael M. Vera. "Estudio de la extracción de tierras raras ligeras a partir de la extracción líquido – líquido utilizando ácidos organofosforados y ácido ascórbico." Revista de Metalurgia 55, no. 2 (June 19, 2019): 142. http://dx.doi.org/10.3989/revmetalm.142.
Full textCabrera, Rosa, Rita Stumpo, Paula López, Graciela Ferraro, Osvaldo Cascone, and Hector M. Fernández-Lahore. "Separación de Proteínas en Mezclas Biológicas Complejas Mediante Procesos Continuos de Extracción Líquido-Líquido." FABICIB 5 (December 6, 2005): 107–18. http://dx.doi.org/10.14409/fabicib.v5i1.672.
Full textSierra-Rodríguez, M. A., J. M. López-López, and S. Jiménez-Prada de Miguel. "Perfluorocarbono líquido subfoveal. Extracción después de 3 meses." Archivos de la Sociedad Española de Oftalmología 91, no. 12 (December 2016): 596–98. http://dx.doi.org/10.1016/j.oftal.2016.02.004.
Full textRodríguez de San Miguel, E., J. De Gyves, M. Muñoz, and M. Valiente. "Aplicación del programa LETAGROP-DISTR al análsis de datos en equilibrios de extracción líquido-líquido." Educación Química 5, no. 4 (August 31, 2018): 224. http://dx.doi.org/10.22201/fq.18708404e.1994.4.66747.
Full textGuerrero Dallos, Jairo Arturo, and Nancy Yohanna Veladia Rodríguez. "Comparación de dos metodologías para la determinación de residuos de plaguicidas en agua potable." Revista Colombiana de Química 43, no. 1 (October 5, 2015): 17–24. http://dx.doi.org/10.15446/rev.colomb.quim.v43n1.50538.
Full textPerales, Liliana Hernández, Leticia Esperanza Hernández Cruz, Felipe Legorreta García, Berenice Mena García, and Mario Ávila Rodríguez. "Selective Recovery of Zn(II) and Fe(III) by Liquid - Liquid Extraction Using Cyphos IL 109 as Extractant." Advanced Materials Research 976 (June 2014): 217–21. http://dx.doi.org/10.4028/www.scientific.net/amr.976.217.
Full textArturo, Jaime, Yovanny Morales, and Daniela Valencia. "Extracción reactiva en procesos controlados por la cinética." Revista de Investigación 9, no. 1 (January 1, 2016): 97–107. http://dx.doi.org/10.29097/2011-639x.44.
Full textGómez Páez, Sebastián. "Estado del arte de correlaciones para el modelamiento del fenómeno de transferencia de masa en columnas de extracción líquido - líquido." Revista de Investigación 11, no. 2 (February 26, 2019): 67–81. http://dx.doi.org/10.29097/2011-639x.229.
Full textCórdova, Javier S., and Elizabeth Paitan. "Determinación de parámetros para obtención y conservación de cuajo de bovino adulto." Ciencia e Investigación 16, no. 1 (June 17, 2013): 9–11. http://dx.doi.org/10.15381/ci.v16i1.8625.
Full textDestéfanis-Petricorena, Carina Alejandra, Abel Eduardo Fernandez-Maurial, María Ursula Cavero-Romaña, and Oscar Alberto Mejia-Sanchez. "Gestión de residuos líquidos en la producción de aceite de oliva en la empresa Deinal S.A.C. Tacna Perú." INGENIERÍA INVESTIGA 3, no. 1 (June 25, 2021): 632–38. http://dx.doi.org/10.47796/ing.v3i1.486.
Full textDissertations / Theses on the topic "Extracción líquido-líquido"
Cid, Cabrera Camila Fernanda. "Desarrollo de metodologías analíticas para la determinación de imidacloprid en agua mediante microextracción líquido-líquido dispersiva (DLLME) y fluorescencia inducida fotoquímicamente asociado a calibración multivariada." Tesis, Universidad de Chile, 2014. http://www.repositorio.uchile.cl/handle/2250/129979.
Full textImidacloprid pertenece a un nuevo tipo de pesticidas llamados neonicotinoides. Estos son pesticidas sistémicos que se distribuyen dentro de las plantas después de ser absorbidos por ellas. Se les utiliza mediante rociado y en recubrimiento de semillas, principalmente para el control de plagas en cultivos como cereales, soja, maíz y muchas frutas y verduras. Desde la introducción de imidacloprid en 1991, el uso de diferentes pesticidas neonicotinoides ha crecido considerablemente, en Chile este pesticida se encuentra entre los 10 más vendidos de acuerdo a reportes del SAG. Debido a su baja lipoficidad y reducida presión de vapor, el imidacloprid es un potencial contaminante de aguas naturales superficiales o subterráneas, ya sea por escorrentía o percolación. Este hecho evidencia la necesidad de establecer la situación ambiental correspondiente mediante el análisis periódico de aguas, lo que a su vez requiere disponer de métodos de análisis adecuados en términos de sensibilidad y selectividad. En esta investigación se desarrolló un método para determinar imidacloprid en aguas, basado en extracción líquido-líquido micro dispersiva (DLLME) y fluorescencia foto-inducida asociada a calibración multivariada. Dado que la eficiencia de la extracción tiene una dependencia multifactorial, ésta fue optimizada mediante superficie de respuesta obteniéndose una recuperación promedio de 61 % (aceptable para las concentraciones del analito evaluadas entre 4 a 14 ng ml -1), utilizando cloroformo-acetonitrilo (extractante-dispersante) en presencia de NaCl y agitación en vortex. La generación de un compuesto fluorescente se logró por irradiación del analito con luz UV a 254 nm, en medio básico, en un sistema batch utilizando un capilar de vidrio. Los espectros de emisión y de excitación-emisión fueron obtenidos mediante espectroscopia de fluorescencia en micro-cubetas de cuarzo en una región amplia de longitudes de onda. El método de cuantificación fue desarrollado utilizando calibración de segundo orden, aplicando mínimos cuadrados parciales desdoblados acoplados a bilinearización residual (U-PLS/RBL) y análisis paralelo de factores (PARAFAC) a matrices de excitación-emisión. Estas herramientas fueron utilizadas para predecir la concentración del analito en presencia de potenciales interferentes (otros pesticidas neonicotiniodes y fipronil). Se analizaron tres grupos de muestras de complejidad creciente, los primeros dos set de validación se realizaron en buffer, el primero sin interferentes y el segundo en presencia de potenciales interferentes, obteniéndose un error de predicción (REP) inferior a 10% y un límite de detección (LOD) igual o inferior a 0,007 μg ml-1. El tercer set de muestras se realizó en presencia de interferentes agregando la etapa de extracción, se compararon estos resultados con los obtenidos mediante el método de referencia HPLC-DAD. Se observó que al agregar la etapa de DLLME se sobre-exige el modelo predictivo de segundo orden debido posiblemente a la co-extracción de otros compuestos no modelados, obteniéndose un error de predicción (REP) de 16% al utilizar U-PLS/RBL y porcentajes de recuperación entre un 50-88%. Este problema se confirmó al analizar un set de muestras reales, en el cual el porcentaje de recuperación obtenido estuvo entre un 27-93%, presentando mayor dificultad las muestras con un alto contenido de materia orgánica o con elevada dureza. Debido a los problemas presentados con DLLME se propuso evaluar un método alternativo de extracción de imidacloprid mediante extracción en fase sólida con columnas de C-18. Se compararon los resultados obtenidos mediante este método con los obtenidos mediante DLLME obteniéndose mejores resultados para la SPE C-18 en cuanto a precisión y recuperación. Posteriormente se analizó nuevamente un set de muestras reales, obteniéndose recuperaciones entre un 64-114%
Imidacloprid belongs to a new type of pesticides called neonicotinoids. These are systemic pesticides which spread within the plants after being absorbed by them. They are used by spraying and seed coating, mainly to control pests in crops such as corn, soybean and many fruits and vegetables. Since the introduction of imidacloprid in 1991, the use of different neonicotinoids pesticides has grown considerably, this pesticide in Chile is among the Top 10 in sales, according to reports from SAG. Due to its low lipophilic and reduced vapor pressure, imidacloprid is a potential contaminant of surface natural waters or groundwater, either by runoff or percolation. This fact highlights the need to establish the appropriate environmental situation through regular analysis of water, which in turn requires the availability of appropriate methods in terms of sensitivity and selectivity. In this research, a method was developed to determine imidacloprid in water, based on dispersive liquid-liquid micro-extraction (DLLME) and photo-induced fluorescence associated with multivariate calibration. Given that the extraction efficiency has a multifactorial dependence, it was optimized through response surface obtaining an average recovery of 61% (acceptable for analyte concentrations evaluated between 4 and 14 ng ml -1), using chloroform-acetonitrile (extractant-dispersant) in the presence of NaCl and vortexing. The generation of a fluorescent compound was achieved by irradiating the analyte with UV light at 254 nm, in a basic medium, in a batch system using a glass capillary. The emission spectra and MEE were obtained through fluorescence spectroscopy, using quartz micro-cuvettes in a wide wavelength region. The quantification method was developed using second-order calibration, applying unfolded partial least squares coupled to residual bilinearization (U-PLS/RBL) and parallel factor analysis (PARAFAC), associated with MEE. These algorithms were used to predict the concentration of the analyte in the presence of potential interferents (fipronil and others neonicotinoids pesticides). Under these conditions, three groups of samples of increasing complexity were analyzed; the first two validation sets were performed in buffer, the first one without interferents and the second in presence of potential interferents, obtaining a error of prediction (REP) under 10% and a limit of detection (LOD) equal or lower than 0.007 μg ml-1. The third set of samples was performed in the presence of interferents, including the extraction stage; these results were compared with those obtained by the reference method HPLC-DAD. It was noted that adding the step of DLLME over-demands the model, possibly due to the co-extraction of other not modeled compounds, yielding 16% as error of prediction (REP) when using U-PLS/ RBL and recovery rates between 50-88 %. This problem was confirmed by analyzing a set of real samples, in which the recovery rate obtained was between 27-93%, being the most difficult samples those with high organic content or high hardness. Due to problems presented with DLLME, it was proposed to conduct an alternative imidacloprid extraction method through solid phase extraction (SPE) using C18 columns. The results obtained by this method were compared with those obtained by DLLME, yielding better results for the C18 SPE for precision and recovery. Subsequently, a set of real samples were analyzed once again, obtaining recoveries between 64-114%
Hidalgo, Muñoz Manuela. "Especiación de metales preciosos en sistemas líquido-líquido y su aplicación en procesos de separación mediante membranas líquidas soportadas." Doctoral thesis, Universitat Autònoma de Barcelona, 1991. http://hdl.handle.net/10803/3263.
Full textCerón, Neculpan Masiel Susana. "Determinación de hidrocarburos aromáticos policíclicos por medio de extracción homogénea líquido-líquido y cromatografía líquida de alta eficiencia en muestras acuosas prístinas." Tesis, Universidad de Chile, 2012. http://www.repositorio.uchile.cl/handle/2250/113601.
Full textAutorizada por el autor, pero con restricción para ser publicada a texto completo en el Portal de tesis, hasta enero de 2017
Los hidrocarburos aromáticos policíclicos (HAPs) son una familia de más de 100 compuestos orgánicos; presentan al menos dos anillos aromáticos fusionados y son derivados principalmente de la combustión incompleta de biomasa y combustibles fósiles. Son ubicuos y su formación, fuentes y depositación son ampliamente estudiadas. En este contexto, es muy relevante su control en muestras ambientales. La presencia de los HAPs en diferentes matrices de Antártica y Groenlandia (suelos, sedimentos, nieve y agua de mar) ha sido detectada en niveles muy bajos de concentración. Debido a los niveles del orden de ultratrazas de estos compuestos en matrices acuosas de zonas remotas, las etapas de extracción y pre-concentración son requeridas previo a su determinación analítica. La extracción homogénea líquido-líquido (HLLE) constituye un método promisorio en cuanto a exactitud y precisión y presenta una serie de ventajas de tipo práctico (simple, tiempos cortos de extracción, bajo costo y uso de pequeños volúmenes de solvente) y entre ellas destaca la posibilidad de usar pequeños volúmenes de muestra, como los obtenidos en sistemas de fusión en continuo con muestreo discreto de testigos de hielo; dichas muestras son homogéneas y permiten obtener alta resolución temporal para el estudio de composición química en testigos de hielo. El objetivo de esta investigación fue desarrollar una metodología analítica basada en HLLE apropiada para el estudio de hidrocarburos aromáticos policíclicos en muestras acuosas prístinas obtenidas desde un testigo de hielo de Antártica. En HLLE los analitos son extraídos desde una solución homogénea en un pequeño volumen de fase sedimentada, formada por el fenómeno de separación de fases, en un sistema de componentes ternarios. La metodología de extracción se desarrolló y optimizó mediante técnicas de diseño multivariado utilizando cromatografía líquida de alta eficiencia con detección de arreglo de diodos (HPLC-DAD) para, posteriormente, validar el método de determinación de los compuestos por cromatografía líquida de alta eficiencia con detección de fluorescencia (HPLC-FLD), a fin de obtener límites de detección y cuantificación apropiados, de acuerdo a los niveles de concentración esperados en las muestras. La extracción desde muestras acuosas muy diluidas se realizó por adición de una mezcla de cloroformo y metanol y agitación manual por 30 segundos. La separación de fases fue por adición de NaCl, recuperándose el extracto (fase sedimentada) por centrifugación. Aplicando un diseño factorial a tres niveles con tres factores (33) se establecieron las condiciones óptimas de extracción y determinación simultánea para naftaleno, fenantreno, antraceno, benzo[k]fluoranteno, benzo[b]fluoranteno acenaftileno, fluoreno, fluoranteno, benzo[a]pireno (BaP), benzo[g,h,i]perileno, dibenzo[a,h]antraceno, indeno[1,2,3-c,d]pireno, (BghiP) acenafteno, pireno y criseno. Las condiciones óptimasde extracción fueron: 10% m/v de NaCl, 1,2 mL de CH3OH y 120 μL de CHCl3 (solvente extractante) para 3,5 mL de muestra. Los factores de enriquecimiento logrados fluctuaron entre 32 y 43 en el intervalo 8-50 ng mL-1 para la metodología HLLE-HPLC-DAD y desde 34 a 49 en el intervalo 0,03-0,11 ng mL-1 para HLLE-HPLC-FLD. Las recuperaciones de los HAPs bajo las condiciones óptimas a niveles de concentración de 20 ng mL-1 fluctuaron entre 67 y 92%, con desviaciones estándar relativas entre 0,7 y 5,1 %. Para la detección por fluorescencia las recuperaciones variaron entre 71 y 99 % en el intervalo de concentraciones de 0,048-0,130 ng mL-1, con desviaciones estándar relativas entre 1,1 y 9,9%. Para HLLE-HPLC-FLD la sensibilidad analítica/ límites de detección/ límites de cuantificación estuvieron entre 0,0078/ 0,0203/ 0,0676 ng mL-1 para fluoranteno y 0,0006/ 0,0015/ 0,0051 ng mL-1 para antarceno. Un comportamiento lineal para la extracción fue establecido, con valores de R2 entre 0,9654 para fluoranteno y 0,9998 para antraceno. La aplicación de HLLE-HPLC-FLD en muestras acuosas prístinas, correspondientes a secciones de un testigo de hielo, permitió la detección y cuantificación en el orden de los pg mL-1 de la mayoría de los analitos (menos BaA y coroneno) en las muestras, encontrándose diferencias a diferentes profundidades al considerar el total de HAPs estudiados.
Polycyclic aromatic hydrocarbons (PAHs) are a family of over 100 organic compounds, having at least two fused aromatic rings. They are derived mainly from the incomplete combustion of fossil fuel and biomass. PAHs are ubiquitous and their formation, sources and fate have been extensively reviewed. In this context their control on environmental samples is highly relevant. The presence of PAHs in various matrices in Antarctica and Greenland (soil, sediment, snow and sea water) has been detected at very low concentrations levels. According to the ultra-trace levels in aqueous matrices from remote areas an extraction and pre-concentration step, prior to the analytical determination is required. Homogeneous liquid–liquid extraction (HLLE) is a promising method for the determination of organic compounds in aqueous matrices because of its accuracy and precision. In addition it presents several practical advantages (simple, with short extraction times, low cost and use of small volumes of solvent). This technique allows using small sample volumes, such as those attained from continuous ice core melter system with discrete sampling for different chemical analysis. These samples are homogeneous and provide a high temporal resolution for the study of ice core chemical composition. The objective of this research was to develop an analytical methodology based on HLLE appropriate for the study of polycyclic aromatic hydrocarbons in pristine aqueous samples obtained from an ice core of Antarctic. In HLLE analytes are extracted from a homogeneous solution in a small volume of sedimented phase formed by a phase separation phenomenon in a ternary component system. The extraction methodology was developed and optimized using multivariate design by using high-performance liquid chromatography with diode array detection (HPLC-DAD) for the analytical determination of PAHs. In a second stage the method was validated for the determination of compounds by high-performance liquid chromatography with fluorescence detection (HPLC-FLD) in order to achieve the appropriate limits of detection (LODs) and quantification (LOQs) according to the possible concentration levels of samples. The extraction from very dilute aqueous samples was performed by adding a mixture of chloroform and methanol and manual shaking for 30 seconds. Phase separation was performed by adding NaCl and the extract (sedimented phase) was recovered by centrifugation. The optimization was carried out by applying a three-level factorial design with three factors (33) for the simultaneous extraction and analytical determination of 15 PAHs from water samples: naphthalene, phenanthrene, anthracene, acenaphthylene, fluorene, fluoranthene, benzo[k]fluoranthene, benzo[b]fluoranthene benzo[a]pyrene, acenaphthene, benzo[g,h,i]perylene, chrysene, pyrene, dibenzo[a,h]anthracene and indeno [1,2,3-c,d] pyrene. Optimal conditions were: 10% w/v of NaCl, 1.2 mL of CH3OH and 120 μL of CHCl3 (extracting solvent) for 3.5 mL of sample. The enrichment factors obtained were between 32 and 43 in the range 8-50 ng mL-1 for the HLLE-HPLC-DAD methodology and from 34 to 49 in the range 0.03-0.11 ng mL-1 for HLLE-HPLC-FLD. Recoveries under optimal conditions for a PAHs concentration levels of 20 ng mL-1 varied between 67 and 92% with a relative standard deviation between 0.7 and 5.1 %. For fluorescence detection mean recoveries were 71-99 % in the concentration range 0.048 -0.13 ng mL-1, with a relative standard deviation of 1.1-9.9% Analytical sensitivity/detection limit and quantification limits for the whole method varied between 0.0078/ 0.0203/ 0.0676 ng mL-1 for fluoranthene and 0.0006/ 0.0015/ 0.0051 ng mL-1 for anthracene. A linear behavior for the extraction method was established with R2 values between 0.9654 for fluoranthene and 0.9998 for anthracene. The application of HLLE-HPLC-FLD to aqueous pristine samples from ice core sections allowed the detection and quantification in the order of pg mL-1, of most analytes (less coronene and BaA) in samples. Significant differences were found at different depths when the total PAHs under study were considered.
Conicyt
Ruiz, Garay Germán Martín, and Rotta Juan José Saavedra. "Determinación de los parámetros óptimos de funcionamiento para un equipo de extracción sólido-líquido en la extracción de aceite esencial de naranja usando un sistema de cáscara de naranja-alcohol etílico." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2007. https://hdl.handle.net/20.500.12672/431.
Full textTesis
Reyes-Labarta, Juan A. "Diseño de columnas de rectificación y extracción multicomponente: cálculo del reflujo mínimo." Doctoral thesis, 1998. http://hdl.handle.net/10045/10023.
Full text