Academic literature on the topic 'EndoTOFPET'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'EndoTOFPET.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "EndoTOFPET"

1

Bugalho, R., C. Gaston, M. D. Rolo, J. Carlos Silva, R. Silva, and J. Varela. "EndoTOFPET-US data acquisition system." Journal of Instrumentation 8, no. 02 (February 22, 2013): C02049. http://dx.doi.org/10.1088/1748-0221/8/02/c02049.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Laugier, R., and P. Lecoq. "47 GOALS AND CHALLENGES OF THE ENDOTOFPET-US FP7 PROJECT." Radiotherapy and Oncology 102 (March 2012): S16. http://dx.doi.org/10.1016/s0167-8140(12)70031-2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Aubry, N., E. Auffray, F. B. Mimoun, N. Brillouet, R. Bugalho, E. Charbon, O. Charles, et al. "EndoTOFPET-US: a novel multimodal tool for endoscopy and positron emission tomography." Journal of Instrumentation 8, no. 04 (April 2, 2013): C04002. http://dx.doi.org/10.1088/1748-0221/8/04/c04002.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Frisch, Benjamin. "Combining endoscopic ultrasound with Time-Of-Flight PET: The EndoTOFPET-US Project." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 732 (December 2013): 577–80. http://dx.doi.org/10.1016/j.nima.2013.05.027.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Zvolský, Milan. "EndoTOFPET-US – A Miniaturised Calorimeter for Endoscopic Time-of-Flight Positron Emission Tomography." Journal of Physics: Conference Series 587 (February 13, 2015): 012068. http://dx.doi.org/10.1088/1742-6596/587/1/012068.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Pizzichemi, M. "Development of EndoTOFPET-US, a multi-modal endoscope for ultrasound and time of flight positron emission tomography." Journal of Instrumentation 9, no. 02 (February 5, 2014): C02002. http://dx.doi.org/10.1088/1748-0221/9/02/c02002.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "EndoTOFPET"

1

CUCCIATI, GIACOMO. "Optimization and characterization of PET scanners for Medical Imaging." Doctoral thesis, Università degli Studi di Milano-Bicocca, 2014. http://hdl.handle.net/10281/83322.

Full text
Abstract:
Positron emission tomography is an imaging technique that appeared to be a valid instrument for cancers detection and neuro-imaging studies. Since first models built during 1960s, an incredible effort has been done by researchers to develop scanners more and more advanced with higher specificity and efficiency. Monte Carlo simulations have shown to be a very important tool during design phase of PET prototypes thanks to their ability to simulate systems with many coupled degrees of freedom, as it happens when particles interact with matter. This Thesis work has started in the frame the Crystal Clear Collaboration when the EndoTOFPET scanner was already under development. This prototype is an high spatial resolution scanner for the study of pancreatic carcinoma and prostatic cancer, composed by a PET head mounted on an ultrasound endoscope and a PET plate to be placed outside the body. The Collaboration has chosen to use Monte Carlo simulations to support the design of this project and two simulations toolkits were available: Geant4 and SLitrani. In this work both the toolkits are studied and ray tracing in scintillator crystals are tested. In particular photon extraction efficiency is simulated under different surface treatments as coating and wrapping. Also the influence of the crystals geometry on light output is tested simulating different scintillators sections and lengths. Both Geant4 and SLitrani have shown to give similar results under these conditions. A main issue was observed regarding secondary particles since Geant4 is able to simulate their production while it is not possible with SLitrani. On other hand crystals anisotropy for optical photons can be activated in SLitrani. Light yield measurements were performed in laboratory on LYSO and PbWO 4 crystals to have a comparison with the results obtained by mean of simulations. Good agreements are obtained for what regards surfaces treatments while more tuning was required to simulate the effect of surface imperfections and diffusion inside crystals. For the Collaboration purposes, Geant4 results more reliable and it allows to use GATE, an open source software specifically developed for the simulation of medical imaging scanners. Due to the peculiar structure of the PET prototype it was necessary to develop a code to simulate the electronic chain, responsible for transforming the gammas detected in usable data for image reconstruction. Different coincidences sorting algorithms were studied and methods to introduce instrumental uncertainties in data were developed and reported in this work. Simulations of EndoTOFPET scanner with different scintillator dimensions, modules geometries and plate configurations were performed. Sensibility and spatial resolution were used as elements of comparison and results collected by simulations are reported and analysed in this work. Time of flight was tested applying different time resolutions while system response to DOI analysis was studied too. Thanks to these first simulations, valuable information for the developing of this prototype were collected.
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "EndoTOFPET"

1

Zorraquino, C. "EndoTOFPET-US a High Resolution Endoscopic PET-US Scanner Used for Pancreatic and Prostatic Clinical Exams." In IFMBE Proceedings, 451–54. Cham: Springer International Publishing, 2014. http://dx.doi.org/10.1007/978-3-319-00846-2_112.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "EndoTOFPET"

1

Cortinovis, Daniele. "EndoTOFPET-US: an endoscopic Positron Emission Tomography." In 53rd International Winter Meeting on Nuclear Physics. Trieste, Italy: Sissa Medialab, 2015. http://dx.doi.org/10.22323/1.238.0045.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Varela, Joao. "EndoTOFPET-US: Multi-modal endoscope for Ultrasound and Time of Flight PET." In 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). IEEE, 2014. http://dx.doi.org/10.1109/nssmic.2014.7430747.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Garutti, Erika. "EndoTOFPET-US a novel multimodal tool for endoscopy and Positron Emission Tomography." In 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference (2012 NSS/MIC). IEEE, 2012. http://dx.doi.org/10.1109/nssmic.2012.6551481.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

"EndoTOFPET-US: Towards a multi-modal endoscope for Ultrasound and Time of Flight PET." In 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC). IEEE, 2013. http://dx.doi.org/10.1109/nssmic.2013.6829146.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

"EndoTOFPET-US DAQ, designing the Data Acquisition System of a high resolution endoscopic PET-US detector." In 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC). IEEE, 2013. http://dx.doi.org/10.1109/nssmic.2013.6829207.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Auffray, E., F. Ben Mimoun Bel Hadj, N. Brillouet, P. Coudray, K. Doroud, G. Fornaro, B. Frisch, et al. "Design and performance of detector modules for the endoscopic PET probe for the FP7-project EndoTOFPET-US." In 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference (2012 NSS/MIC). IEEE, 2012. http://dx.doi.org/10.1109/nssmic.2012.6551739.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography