Academic literature on the topic 'Differentially Pumped Chamber; Ansys Fluent; Diferenciálně čerpaná komora'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Differentially Pumped Chamber; Ansys Fluent; Diferenciálně čerpaná komora.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Dissertations / Theses on the topic "Differentially Pumped Chamber; Ansys Fluent; Diferenciálně čerpaná komora"

1

Balobanov, Damir. "Vliv způsobu čerpání experimentální komory na průběh teploty plynu." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2021. http://www.nusl.cz/ntk/nusl-442558.

Full text
Abstract:
The master‘s thesis is focused on issue of pumping in the experimental pumped chambre of an environmental scanning microcope. In the theoretical part, there are presented microscopy as science. Afterwards the thesis is focused on electron microscopy and its problem and vakuum system, computer program used for preparation of simulation and study that the experimental part is based on. The experimental part contains the results of gas flow in the differential pumped chambre. The problematics were solved by Ansys Fluent system.
APA, Harvard, Vancouver, ISO, and other styles
2

Polách, Ondřej. "Optimalizace tvaru čerpání diferenciálně čerpané komory pro novou koncepci elektronového mikroskopu." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2015. http://www.nusl.cz/ntk/nusl-221092.

Full text
Abstract:
The present work deals with electron microscopy, electron microscopy primarily environmental. The main task of the work will draft the optimal shape of the differentially pumped chamber, dividing the pressure difference between tube and chamber with sample for a new concept of an electron microscope. By ANSYS Fluent will be analyzed pumping gas. Subsequently, according to the results obtained will be a modified form of the differential Chamber and to achieve the lowest gas pressure on the track of the electron beam.
APA, Harvard, Vancouver, ISO, and other styles
3

Bílek, Michal. "Analýza tvaru sacích kanálů současné koncepce diferenciálně čerpané komory." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2015. http://www.nusl.cz/ntk/nusl-221313.

Full text
Abstract:
This master´s thesis discusses the analysis of the shape of the intake ports of differentially pumped chamber for the current concept. The first part is an introduction to the microscopy issue, then it is focused on ESEM microscopes and it also includes a describtion of the Flow dynamics and a mathematical describtion. In the following chapters the software Solid Works, where the model of differentially pumped chamber is created, and the software Ansys Fluent, which is used for analysis, are described. The second part concerns the proposed concepts and the results of their simulations. At the end of the work the results are analyzed and evaluated.
APA, Harvard, Vancouver, ISO, and other styles
4

Lepltová, Kristýna. "Matematicko - fyzikální analýza dynamického tlaku pro experimentální diferenciální komoru." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2018. http://www.nusl.cz/ntk/nusl-376980.

Full text
Abstract:
This thesis is based on the series of scholarly article dedicated to the issue of pumping in the differential scanning chamber of an environmental scanning microscope. The thesis is based on Danilatos’s study where the pumping of the differential pumped chamber is solved by means of the Monte Carlo statistical method. The thesis analyzes gas flow in the experimental chamber using the Pipot tube. The analyses will be used for the design of the experimental chamber which will serve for the experimental evaluation of the flow results in the chamber using the continuum mechanics.
APA, Harvard, Vancouver, ISO, and other styles
5

Rous, Miroslav. "Analýza vlivu umístění kónické clony v nadzvukovém proudu v komoře diferenciálního čerpání." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2018. http://www.nusl.cz/ntk/nusl-377065.

Full text
Abstract:
The thesis is focused on the medium dynamics simulation in the environmental scanning electron microscope. Specifically, it researches (examines) the conical aperture location effect in the differential pumped chamber and the width of the pumping channel in this chamber. The theoretical part deals with the environmental scanning microscope generally and other tools used in this thesis, e.g. ANSYS Fluen software, fluid turbulence, medium free path of molecules and electrons scattering. In the practical part, the work is focused on data processing from the ANSYS Fluent program and on their evaluation.
APA, Harvard, Vancouver, ISO, and other styles
6

Bednář, Eduard. "Analýza vlivu proudění plynu v oblasti umístění vzorku v komoře enviromentálního rastrovacího elektronového mikroskopu." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2016. http://www.nusl.cz/ntk/nusl-242067.

Full text
Abstract:
This thesis deals with the simulation of fluid dynamics in environmental scanning electron microscope and evaluate solvers setup, the degree of discretization, choice of turbulent model and proposal optimal design of environmental scanning electron microscope. The theoretical part describes the issue of environmental scanning electron microscopy, software SolidWorks and ANSYS Fluent, basic equations describing fluid status, fluid turbulence, the mean free path of molecules and electron scattering. The practical part of the thesis is to create the model of environmental scanning electron microscope AQUASEM II in CAD system SolidWorks and simulation of fluid flow in the sample chamber before aperture PLA1 by ANSYS Fluent. A series of simulations provided the perfect setting solver. These knowledge are used in the second stage of the practical part, where is proposed optimal shape of the table sample and the input aperture PLA1.
APA, Harvard, Vancouver, ISO, and other styles
7

Šimík, Marcel. "Specifika nastavení řešiče v systému Ansys Fluent pro nízké tlaky v EREM." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2017. http://www.nusl.cz/ntk/nusl-319633.

Full text
Abstract:
This thesis is focused on electron microscopy which issue is discussed at the beginning of work. The main attention is dedicated to the Environmental electron microscope, especially the differentially pumped chamber, which the thesis deals with. There is a production of an experimental chamber for analysis of shock waves on going therefore main goal of this thesis was to analyze the flow pattern in this chamber. Using the Ansys Fluent program, simulations of the characteristic flow that arises from the pumping of the vacuum chambers namely the ultrasonic flow at low pressures on which the most suitable turbulent module was applied as well as the degree of discretization was performed. The final analysis of this flow pattern is primarily focused on the localization of the shock wave which experimental evidence is to be lodged by shadow optical method as a part of the new concept of the chamber. The basis for the simulation of the chamber was taken over by Dr. Danilatos, with which the results were compared.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography