Academic literature on the topic 'Détecteur d'ondes gravitationnelles'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Détecteur d'ondes gravitationnelles.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Dissertations / Theses on the topic "Détecteur d'ondes gravitationnelles"

1

Gouaty, Romain. "Analyse de la sensibilité du détecteur d'ondes gravitationnelles Virgo." Chambéry, 2006. http://www.theses.fr/2006CHAMS006.

Full text
Abstract:
Le détecteur d'ondes gravitationnelles Virgo est un interféromètre laser dont les bras font trois kilomètres de long. Cet interféromètre est actuellement dans une phase de réglages et d'ajustements ayant pour but d'amener l'instrument à sa sensibilité nominale. Il est pour cela nécessaire de réduire les bruits instrumentaux qui limitent la sensibilité pendant cette phase. Le travail décrit dans ce mémoire est consacré à l'analyse des bruits instrumentaux. Une description des bruits que l'on sait susceptibles de limiter la sensibilité de l'interféromètre est d'abord présentée, ainsi que leur mécanisme de propagation. La méthode ayant permis d'analyser les bruits instrumentaux est ensuite exposée. Elle consiste tout d'abord à identifier les sources de bruit potentielles par la recherche de cohérence entre les signaux de l'interféromètre. Il est ensuite utile de comprendre le mécanisme par lequel ces bruits se propagent dans l'interféromètre en élaborant des modèles analytiques. Cette analyse, appliquée aux données de l'interféromètre, a été complétée par des études utilisant une simulation du détecteur. Entre fin 2003 et fin 2005, les progrès de la mise en route de Virgo ont été ponctués par sept prises de données techniques, qui ont permis de vérifier l'évolution des performances du détecteur. Les résultats de l'analyse des bruits limitant la sensibilité de l'interféromètre au cours de chacune de ces prises de données techniques sont présentés dans ce mémoire. L'impact des améliorations techniques apportées à l'interféromètre pour éliminer l'effet de ces bruits est également discuté
The Virgo detector for gravitational waves is a laser interferometer with arms which are 3 km long. This interferometer is at present in its commissioning phase whose goal is to reach the Virgo nominal sensitivity. To this purpose it is necessary to reduce the technical noises which are limiting the sensitivity during this phase. The work described in this thesis focuses on the analysis of technical noises. The noises which are known to be likely to limit the sensitivity are first described and their propagation mechanism is also explained. The method used to analyse the technical noises is then presented. It first consists in identifying the possible noise sources by looking for coherence between the interferometer signals. Then it is useful to understand how the noise propagates into the interferometer. This is done by building analytical models of propagation. Some studies based on a simulation of the detector have been added to the analysis of interferometer data. Between the end of 2003 and the end of 2005, the advance of the commissioning has been punctuated with seven technical data taking periods, performed in order to check the evolution of the detector performance. The analysis of the noises limiting the interferometer sensitivity for each of these data taking is presented in this thesis. The impact of the technical upgrades implemented on the interferometer to suppress the effect of these noises is also discussed
APA, Harvard, Vancouver, ISO, and other styles
2

Trinquet, Hervé. "Caractérisation de la source laser du détecteur d'ondes gravitationnelles VIRGO." Phd thesis, Université de Nice Sophia-Antipolis, 2003. http://tel.archives-ouvertes.fr/tel-00135165.

Full text
Abstract:
La source laser pour le détecteur d'ondes gravitationnelles VIRGO a été conçue pour délivrer un faisceau stable, continu, mono mode de 20 W à 1.064 μm. Je rappelle dans un premier temps les principales contraintes auxquelles doit répondre la source laser. Je décris ensuite l'architecture du système et les techniques utilisées pour stabiliser le faisceau. Enfin je donne les principales performances obtenues jusqu'en juillet 2002 : puissance de 2.7W avec un niveau de stabilité en fréquence de 500 Hz rms pour un cycle utile de plus de 90%. Dans un second temps, j'étudie les principales sources de bruits et les processus de couplages pouvant expliquer le manque de stabilité du système. Je montre ainsi que le contrôle local utilisé contribue à augmenter le bruit de fréquence et de puissance jusqu'à 10 Hz. Des résonances mécaniques sont identifiées entre 10 Hz et 1 kHz. Ainsi la simplification de l'un des bancs devrait permettre au système de respecter les contraintes.
APA, Harvard, Vancouver, ISO, and other styles
3

Clapson, André-Claude. "Recherche de signaux impulsionnels sur le détecteur d'ondes gravitationnelles Virgo." Phd thesis, Université Paris Sud - Paris XI, 2006. http://tel.archives-ouvertes.fr/tel-00085885.

Full text
Abstract:
Le détecteur d'ondes gravitationnelles par interférométrie optique Virgo atteindra bientôt sa sensibilité nominale.
Les sources astrophysiques attendues sont principalement les coalescences de systèmes binaires d'objets compacts et les supernovas gravitationnelles. Les amplitudes des signaux sont à la limite de la sensibilité de l'instrument, les taux d'événements observables sont faibles et les formes d'ondes mal connues, notamment pour les effondrements gravitationnels.
L'analyse des données repose sur la recherche de signaux de faible amplitude dans du bruit coloré. Dans ce contexte, ce travail propose l'utilisation de décompositions temps-fréquence des séries temporelles pour la détection de signaux courts. Les performances de cette approche sont estimées en simulation et comparées à celles d'autres méthodes de détection disponibles dans la communauté.
Une autre difficulté pour l'analyse est la présence de structures spectrales étroites dans la distribution d'énergie en fréquence des données. Elles proviennent de résonances mécaniques des miroirs et du système d'isolation sismique de l'instrument. L'utilisation de filtres de Kalman pour éliminer ces bruits bien modélisés avant l'analyse est présentée. Le problème essentiel
de l'estimation des paramètres du modèle est traité, avec l'objectif d'une réestimation dynamique.
Enfin ces outils sont appliqués aux données Virgo disponibles, avec comme résultat principal la mise en évidence de sources de bruits instrumentaux importantes, dont la suppression demandera une amélioration du fonctionnement et une meilleure isolation de l'environnement.
APA, Harvard, Vancouver, ISO, and other styles
4

Ducrot, Marine. "Etude des cavités optiques de filtrage de sortie du détecteur d'ondes gravitationnelles Advanced Virgo." Thesis, Université Grenoble Alpes (ComUE), 2016. http://www.theses.fr/2016GREAY046/document.

Full text
Abstract:
Un siècle après leur prédiction par Albert Einstein, le 14 septembre 2015 des ondes gravitationnelles provenant de la coalescence de deux trous noirs ont été observées, ouvrant ainsi le champ à une toute nouvelle astronomie et une nouvelle manière d'étudier la gravitation. La faible amplitude des ondes gravitationnelles nécessite des détecteurs spécifiques et très sensibles. Advanced Virgo est un interféromètre kilométrique de deuxième génération dédié à la détection des ondes gravitationnelles. Un des éléments nécessaires pour atteindre la sensibilité requise est le système optique de filtrage appelé l’Output Mode Cleaner ou OMC, placé en sortie de l'interféromètre, et composé de deux cavités optiques. Ce manuscrit présente l'étude et la caractérisation de ce système optique de filtrage. Ce travail a permis de sélectionner les deux cavités actuellement installées dans le détecteur Advanced Virgo. Les performances de filtrage et l’impact de l’OMC sur la sensibilité du détecteur sont également décrits
About 100 years after their prediction by Albert Einstein gravitational waves produced by the coalescence of two black holes were observed on the 14th of September 2015, opening the field of gravitational wave astronomy and a new way to study gravitation. The small amplitude of gravitational waves requires specific and very sensitive detectors. Advanced Virgo is a second generation kilometric interferometer dedicated to the detection of gravitational waves. A necessary element to reach the required sensitivity is the filtering optical system named the Output Mode Cleaner or OMC, placed at the output of the interferometer, and composed of two optical cavities. This thesis shows the study and characterization of this optical system. This work informed the selection of the two optical cavities actually installed in the Advanced Virgo detector. The filtering performances and impact of the OMC on the detector sensitivity are also described
APA, Harvard, Vancouver, ISO, and other styles
5

Bonnand, Romain. "Le détecteur d'ondes gravitationnelles Advanced Virgo : Étude de la configuration optique et développement des miroirs." Phd thesis, Université Claude Bernard - Lyon I, 2012. http://tel.archives-ouvertes.fr/tel-00797350.

Full text
Abstract:
Les ondes gravitationnelles ont été prédites par Einstein dans sa théorie de la Relativité Générale. Elles sont des perturbations de l'espace-temps que l'on essaie de mettre en évidence par interférométrie laser. Les détecteurs sont des interféromètres de Michelson de plusieurs km de long combinés avec des cavités Fabry- Perot afin d'augmenter la sensibilité de l'instrument. La première génération de détecteurs (Virgo, LIGO, GEO) n'a pas permis d'obtenir une détection directe malgré plusieurs phases d'observations en coïncidence à la sensibilité prévue. Une seconde génération de détecteurs est actuellement en préparation avec notamment le projet européen Advanced Virgo qui devrait avoir une sensibilité améliorée d'un ordre de grandeur. Cette thèse s'intéresse dans un premier temps aux effets de lentille thermique due à la haute puissance contenue dans les cavités Fabry-Perot pour différentes configurations optiques de l'interféromètre. Par la suite, nous nous intéresserons aux miroirs qui composent les cavités Fabry-Perot depuis la définition des besoins en termes de planéité à la réalisation de cette planéité et à sa mesure. La planéité de ces miroirs doit être sub-nanométrique de façon à limiter les pertes optiques dans les cavités Fabry-Perot et ainsi réduire les effets du bruit de photons et de la lumière diffusée. Nous verrons la réalisation de la correction de la planéité des substrats par la technique dite du traitement correctif. Nous étudierons aussi l'uniformité du dépôt des couches minces diélectriques nécessaires à l'obtention de surface hautement réfléchissante avec en particulier l'étude du mouvement planétaire des substrats dans la machine de dépôts.
APA, Harvard, Vancouver, ISO, and other styles
6

Bondu, François. "Etude du bruit thermique et stabilisation en fréquence du laser du détecteur interferométrique d'ondes gravitationnelles VIRGO." Phd thesis, Université Paris Sud - Paris XI, 1996. http://tel.archives-ouvertes.fr/tel-00002892.

Full text
Abstract:
La sensibilité d'un détecteur interférométrique d'ondes gravitationnelles comme Virgo est cruciale pour l'analyse des sources astrophysiques. Une telle antenne détecte l'onde gravitationnelle comme une variation de phase de faisceau lumineux. La précision de la mesure peut être limitée par le bruit de longueur des cavités. dû aux vibrations thermiques, et par le bruit de fréquence du laser incident. Ma contribution à l'évaluation du bruit des modes de vibration interne des substrats des miroirs a été d'écrire un programme, basé sur la propagation des ondes acoustiques dans les solides. Il permet les calculs des fréquences de résonance, des masses équivalentes des modes, de la déformation de la surface et son couplage avec un faisceau lumineux incident. Les résultats permettent le dimensionnement des substrats. La sensibilité est alors légèrement moins bonne que celle fournie par une estimation grossière, si les pertes des ondes acoustiques sont constantes en fonction de la fréquence et égales à celles mesurées à résonance. Elle peut être améliorée par diminution des pertes ou par le choix d'un matériau ayant de meilleures performances. Nous avons également mené des expériences pour aider au choix du matériau des fils de suspension. Je propose une expérience de mesure directe du bruit thermique qui permettrait de vérifier la sensibilité.
La configuration de l'interféromètre rend le bruit de fréquence du laser négligeable si le laser est asservi en fréquence. La stabilisation de fréquence se fera en deux étages, l'un qui asservit la fréquence sur la longueur d'une cavité courte, le deuxième qui asservit sur les grands bras de l'interféromètre. Le premier étage a été construit. J'ai vérifié que ses performances remplissent les spécifications. La stabilité de fréquence obtenue se révèle être exceptionnelle.
APA, Harvard, Vancouver, ISO, and other styles
7

Grave, Xavier. "Etude de méthodes pour la recherche avec le détecteur VIRGO d'ondes gravitationnelles émises par des étoiles à neutrons." Phd thesis, Université Paris Sud - Paris XI, 1997. http://tel.archives-ouvertes.fr/tel-00003045.

Full text
Abstract:
Le but de l'expérience Virgo est la détection des ondes gravitationnelles. L'objet de cette thèse est l'étude de méthodes pour la recherche de signaux émis par des étoiles à neutrons ainsi que l'étalonnage du détecteur.
Dans une première partie, l'étoile à neutrons et son émission d'ondes gravitationnelles, sont présentées. Ensuite le détecteur, les principales sources de bruits, ainsi que la solution adoptée pour l'étalonnage sont décrits.
Puis dans une seconde partie la modélisation des effets dus aux mouvements de la terre (effet Doppler, modulation d'amplitude) est décrite. Leurs conséquences sur le rapport signal sur bruit sont déterminées.
Les deux derniers chapitres sont consacrés aux algorithmes de recherche de signaux périodiques. Tout d'abord le cas où la position de la source est connue est présenté. Le ralentissement de la rotation de la source et la correction de cet effet sont décrits. La correction de l'effet Doppler est aussi détaillée. De même, le problème de la gestion du gigantesque flot de données à traiter est abordé, et une solution y est apportée. Finalement la difficulté de recherche multidirectionnelle est présentée. Des prototypes d'algorithmes hiérarchiques sont aussi évalués.
APA, Harvard, Vancouver, ISO, and other styles
8

Barsuglia, Matteo. "Stabilisation en fréquence du laser et contrôle de cavités optiques à miroirs suspendus pour le détecteur interférométrique d'ondes gravitationnelles." Phd thesis, Université Paris Sud - Paris XI, 1999. http://tel.archives-ouvertes.fr/tel-00006570.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Drezen, Christine. "Utilisation de caméras CCD pour le contrôle du détecteur d'ondes gravitationnelles VIRGO : élaboration d'une interface VME et analye d'images." Université Joseph Fourier (Grenoble ; 1971-2015), 1997. http://www.theses.fr/1997GRE10147.

Full text
Abstract:
Virgo est un interferometre kilometrique concu pour la detection des ondes gravitationnelles. Ses miroirs suspendus doivent etre controles en permanence afin d'assurer un fonctionnement optimal du detecteur. Puisque l'interferometre doit fonctionner 24 heures sur 24, le dispositif necessite un controle efficace de la position des optiques et l'analyse des formes de faisceaux pendant l'alignement ou le realignement. Un tel controle doit s'exercer en temps reel et doit s'integrer dans le systeme complexe d'asservissement de l'interferometre. Cette these decrit le systeme d'imagerie constitue d'une camera ccd, d'une interface vme et des outils logiciels associes. Leurs applications au controle local des objets suspendus et a l'alignement initial de l'interferometre est presente. Le controle local qui mesure les six degres de liberte d'un miroir suspendu, par rapport a un systeme de reference local, est detaille. Ce controle est essentiellement applique a la memorisation des positions des miroirs ainsi qu'a l'amortissement de leurs mouvements pendulaires. L'analyse d'images est utilisee au demarrage de l'alignement de l'interferometre. Elle controle la position des impacts de faisceaux sur les miroirs. Le modele est teste sur un dispositif experimental et par simulation.
APA, Harvard, Vancouver, ISO, and other styles
10

Arnaud, Nicolas. "Contrôle global de la partie centrale du détecteur d'ondes gravitationnelles Virgo. Recherche de signaux impulsionnels: application aux coincidences entre interféromètres." Phd thesis, Université Paris Sud - Paris XI, 2002. http://tel.archives-ouvertes.fr/tel-00006624.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography