Dissertations / Theses on the topic 'Dental implants'

To see the other types of publications on this topic, follow the link: Dental implants.

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Dental implants.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Hultin, Margareta. "Factors affecting peri-implant tissue reactions /." Stockholm, 2001. http://diss.kib.ki.se/2001/91-628-4761-9/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Vermeulen, Lisa. "Development of a radiographic dental implant guide for forensic identification using current dental implants." Thesis, Cape Peninsula University of Technology, 2018. http://hdl.handle.net/20.500.11838/2755.

Full text
Abstract:
Thesis (MSc (Radiography))--Cape Peninsula University of Technology, 2018.
Introduction: Forensic dentistry plays a key role in identifying human remains that cannot be identified visually or by other means. Studies have shown that in cases of single or multiple deaths, scientific identification of human remains utilising forensic dentistry is often the most successful source of identification. Dental identification of human remains consists of a very complex procedure that makes it necessary during the investigation process to use and compare unique dental identifiers. A reliable and accurate method of identifying human remains is a positive radiological identification between ante-mortem and post-mortem images of dental radiographic images. Even if ante-mortem radiographic images may not be present during the identification process, post-mortem images may include details of dental restorations such as dental implants which cannot be seen during visual examination. The different types of dental implants vary in morphology and in conjunction with the unique appearance of dental anatomy and the placement of custom restorations such as dental implants, it has been found to accurately assist in the identification of human remains. Objectives: To establish a radiographic dental implant guide for ten commonly used dental implant types in the Western Cape, South Africa; and to identify and describe the morphological characteristics of these dental implant types as observed on pantomographs. Methods: The ten commonly used dental implant types were imaged radiographically to create a reference instrument which served as a tool for identifying and comparing different types of dental implants. The morphologies of the different dental implants, specifically the apex, thread and neck, were observed on ante-mortem pantomographs and compared to the appearance of the dental implants on the reference instrument to make a positive match. The straight tube image of all ten dental implant types in the reference instrument was used as the point of reference to positively identify the morphological characteristics of each dental implant type on the pantomographs. The morphological characteristics of the ten commonly used dental implant types used in the Western Cape were described and based on this a radiographic dental implant guide was developed. Results: A total of 384 dental implants were observed on the pantomographs. Of these, 380 dental implants could be positively identified on the pantomographs while 4 dental implants could not. A total of 350 dental implants (91%) were identified as dental implant types listed in the reference instrument while 30 dental implants were identified as a dental implant type not listed in the reference instrument. A total of 208 dental implants (54.2%) could be positively identified using the morphological characteristics namely the apex, thread and neck on the straight tube images of the dental implant type in the reference instrument. The radiographic dental implant guide was developed based on positive identification of the morphological characteristics of the dental implant types. Conclusion: This research study has illustrated that the morphology of dental implants can be used to differentiate between different dental implant types on pantomographs. Each dental implant type had unique morphological characteristics as well as similarities which enabled distinction between the different dental implant types, which facilitated dental implant identification and the development of a radiographic dental implant guide. The radiographic dental implant guide developed as part of this research study, may be useful in the field of forensic dentistry and forensic radiology.
APA, Harvard, Vancouver, ISO, and other styles
3

Blázquez, Hinarejos Mónica. "Diferencias histológicas en la adhesión del tejido conectivo alrededor de pilares sobre implantes tratados con láser y pilares convencionales." Doctoral thesis, Universitat de Barcelona, 2017. http://hdl.handle.net/10803/461943.

Full text
Abstract:
INTRODUCCIÓN. Uno de los retos más importantes hoy en día en implantología oral es evitar la pérdida ósea alrededor de los implantes oseointegrados y funcionales con el paso del tiempo. Una de las superficies que se ha desarrollado en los últimos años es la resultante de la microtexturación mediante láser. Diversos estudios han demostrado la adhesión del tejido conectivo a las superficies tratadas con láser en la zona cervical de los implantes oseointegrados, consiguiendo de este modo un sellado biológico a este nivel. Otras investigaciones hacen pensar que este sellado o adhesión mediante fibras de colágeno podría ser beneficioso en el pilar prostodóncico definitivo que se fija al implante. Se adquiriría mejor sellado en la zona cervical del pilar, de este modo se evitaría la migración bacteriana a este nivel y por consiguiente la pérdida ósea alrededor del implante. OBJETIVOS. Comparar las diferencias de adhesión del tejido gingival circundante entre los pilares tratados mediante láser y los pilares sin dicho tratamiento de superficie en humanos. MATERIAL Y MÉTODOS. Se involucran en el estudio clínico un total de seis participantes y doce implantes insertados, seis de ellos conectados a pilares con tratamiento láser y los otros seis a pilares de titanio lisos sin tratamiento de superficie. Tras 90 días de la inserción quirúrgica se retiran los pilares junto a 1 mm de tejido gingival y se procesan las muestras para su observación histológica. RESULTADOS. En las fotografías de microscopia óptica se observa que no existe unión del tejido gingival al pilar liso, contrariamente a lo sucedido en los pilares con tratamiento láser donde sí se observa adhesión del tejido. La media de porcentaje de TAC (Tissue Abutment Contact) en el pilar con tratamiento láser fue del 98,8% y en el pilar control liso fue del 24,1%. DISCUSIÓN. Todos los participantes tuvieron una evolución favorable con una cicatrización óptima de los tejidos y se rehabilitaron definitivamente con un pilar con tratamiento láser. El método utilizado tanto para el procesado de las muestras como para el cálculo de el análisis cuantitativo permitió cumplir los objetivos del estudio. Se plantean futuras líneas de investigación como el seguimiento de los participantes en el estudio a medio o largo plazo. CONCLUSIÓN. El tejido conectivo tiene una mejor adhesión a los pilares tratados con láser en comparación a los pilares lisos sin tratamiento de superficie.
INTRODUCTION. Achievement of implant stability and maintenance of crestal bone levels are prerequisites for a successful long-term function of dental implants. One of the surfaces which have been developed with that goal is the microtexturizing of the implant neck through laser application. Several studies have shown the adhesion of the connective tissue on the laser treated surfaces on the cervical region of osseointegrated implants, with the achievement of a biological seal at that level. Other studies suggest that this sealing or adhesion through collagen fibers could be benefitial on the final prosthetic abutment which is connected to the implant. This way it would be possible to achieve a sealing around the cervical region of the abutment, avoiding bacterial migration at that level and, therefore, peri-implant bone loss. OBJECTIVE. The goal of the current study is to compare the difference in connective tissue adherence to laser microtextured versus machined titanium abutments. MATERIAL AND METHODS Six patients and twelve dental implants were enrolled in the study, six of them fixed to laser treated abutment and the other six fixed to a machined abutment. Ninety days after the first intervention, second surgery was carried out. The abutment was unscrewed, removing a complex formed by the abutment and the surrounding 1 mm of gingival attachment for its histological assessment. RESULTS In the images of optical microscopy we observed intimate adherence between connective tissue and the laser treated abutments, while on machined abutments no adherence was detected. The mean percentage of TAC (Tissue Abutment Contact) on laser treated abutment was 98.8%, and 24.1% on the machined abutment. DISCUSSION All participants in the study had optimal healing and a treated laser abutment was placed the usual prosthetic protocol. We achieved the study objectives with both histological assessment and quantitative analysis methods. Futures lines of research are proposed as the follow-up of the partcipants in the study for medium or long term. CONCLUSION Connective tissues show enhanced adherence to microtextured abutments compared to machined abutments.
APA, Harvard, Vancouver, ISO, and other styles
4

Barão, Valentim Adelino Ricardo [UNESP]. "Avaliações biomecânicas e biológicas relacionadas às próteses implanto-suportadas e aos implantes osseointegrados." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/105565.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-31Bitstream added on 2014-06-13T20:25:51Z : No. of bitstreams: 1 barao_var_dr_araca.pdf: 1603640 bytes, checksum: 5d48588f784413a0d8cc560b1ff6d9b0 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Objetivos: (1) Investigar o papel de diferentes níveis de pH da saliva artificial (3; 6,5 e 9) no comportamento corrosivo do titânio comercialmente puro (cp-Ti) e da liga Ti-6Al-4V (Capítulo 1); (2) Avaliar a influência do processo de corrosão na afinidade do lipopolissacarídeo (LPS) de Escherichia coli para o cp-Ti e o Ti-6Al-4V (Capítulo 2); (3) Investigar a natureza tribocorrosiva do titânio em saliva artificial em presença de LPS (Capítulo 3); (4) Comparar o efeito de diferentes designs de overdentures implanto-retidas e prótese total fixa implanto-suportada na distribuição de tensões em mandíbula edêntula pelo método de elementos finitos tridimensional (Capítulo 4). Materiais e métodos: Testes eletroquímicos como potencial de circuito aberto, espectroscopia de impedância eletroquímica, e teste potenciodinâmico foram conduzidos. Para o teste de afinidade ao LPS, os espécimes foram tratados com LPS (1,5; 15 e 150 μg/ml) durante 24 horas para avaliar a aderência de LPS. Os discos foram transferidos a cada 24 horas para solução fresca de água livre de LPS até completar 72 horas, para investigar a liberação de LPS. No teste de tribocorrosão, o pH da saliva (6,5), a concentração de LPS (0, 0,15, 15 and 150 μg/ml), a duração do deslizamento (2000 ciclos), freqüência (1,2 Hz) e carga (20 N) foram usados para mimetizar o processo mastigatório. Finalmente, modelos tridimensionais de uma mandíbula edêntula foram construídos. No grupo OR a mandíbula foi restaurada com overdenture retida por implantes não esplitados com sistema de retenção O’ring; nos grupos BC-C e BC as mandíbulas foram restauradas com overdentures retidas por implantes esplintados com sistema de retenção barra-clipe associado ou não a cantilevers distais...
Objectives: (1) To investigate the role of different levels of pH of artificial saliva (pHs 3, 6.5 and 9) under simulated oral environment on the corrosion behavior of commercially-pure titanium (cp-Ti) and Ti-6Al-4V alloy (Chapter 1); (2) To assess the influence of corrosion process on Escherichia coli lipopolysaccharide (LPS) affinity for cp-Ti and Ti-6Al-4V alloy (Chapter 2); (3) To evaluate the tribocorrosive (corrosion/wear) nature of titanium in artificial saliva (pH 6.5) with LPS (Chapter 3); and (4) To compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible by using a three-dimensional finite element analysis. Materials and methods: Standard electrochemical tests, such as open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic tests were conducted in a controlled environment. For LPS affinity test, specimens were treated with LPS (1.5, 15 and 150 μg/ml) for 24 hours to evaluated LPS adherence. Discs were then transferred every 24 hours to fresh LPS-free water, up to 72 hours, to investigate LPS elution. In the tribocorrosion test, the pH of saliva (6.5); LPS concentration (0, 0.15, 15 and 150 μg/ml), sliding duration (2000 cycles), frequency (1.2Hz) and load (20 N) parameters mimicked the mastication process. Finally, tridimensional models of an edentulous mandible were constructed. In the OR group, the mandible was restored with an overdenture retained by unsplinted implants with O’ring attachment; in the BC-C and BC groups, the mandibles were restored with overdentures retained by splinted implants with bar-clip anchor associated or not with distally placed cantilevers, respectively; in the FD group, the mandible was restored with a fixed full-arch implant-supported prosthesis... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
5

Palacios, Garzón Natalia. "La pérdida marginal ósea en implantes de conexión externa versus conexión interna e implantes crestales y subcrestales." Doctoral thesis, Universitat de Barcelona, 2019. http://hdl.handle.net/10803/671196.

Full text
Abstract:
INTRODUCCIÓN: Cuando se coloca un implante, se asume que habrá una pérdida de hueso en la zona más coronal alrededor de este. La colocación del implante respecto al nivel de hueso ya sea crestal o subcrestal y el tipo de conexión elegida, ya sea conexión externa o interna, se han relacionado como algunos de los factores causantes de la pérdida de hueso alrededor de implantes. La preservación del hueso periimplante, es fundamental porque influye sobre la forma y el contorno de los tejidos blandos suprayacentes, que son importantes para el resultado estético del tratamiento y para el éxito de los mismos. El objetivo principal de esta tesis fue evaluar la pérdida de hueso marginal tanto en implantes de conexión externa e interna, como en implantes colocados a nivel crestal y subcrestal. Se ha sugerido que en la conexión externa y en la colocación subcrestal de los implantes existe mayor pérdida de hueso marginal, sin embargo, la literatura no es clara al respecto. Por este motivo se realizaron dos revisiones sistemáticas para responder a las siguientes preguntas: “En pacientes tratados con implantes dentales, ¿hay diferencia entre la conexión externa e interna en términos de pérdida ósea marginal alrededor de las conexiones? y ¿hay diferencias entre la colocación subcrestal y crestal en términos de pérdida ósea marginal? En la primera revisión se analizaron las conexiones. Se incluyeron 10 artículos que incluían 1.523 pacientes con 3.965 implantes. De acuerdo con esta revisión y considerando las limitaciones debidas a los grados de heterogeneidad entre los estudios incluidos, ambas conexiones presentaron altas tasas de supervivencia. Así todo y que la conexión interna es la que parece gozar de mayor reconocimiento en la actualidad; los estudios incluidos en esta revisión, caracterizados por un gran número de muestra y largos periodos de seguimiento demostraron que la conexión externa era una conexión fiable, avalada por estudios de longevidad. Respecto a la segunda revisión y metaanálisis, en la que se analizó la colocación a nivel crestal o subcrestal de los implantes, se obtuvieron resultados clínicos apropiados. Teniendo en cuenta la falta de evidencia científica en ambos aspectos y con la intención de poder aportar claridad a la hora de elegir la conexión del implante y su posicionamiento vertical respecto al hueso, planteamos la realización de un ensayo clínico aleatorio, con el objetivo de determinar si la pérdida de hueso difería significativamente entre las dos conexiones y las posiciones verticales del implante. MATERIAL Y MÉTODO : Los pacientes fueron reclutados del Máster de Medicina Cirugía e Implantología Oral. Facultat de Medicina i Ciencies de la Salut (Odontología). Y fueron atendidos en el Hospital Odontològic Universitat de Barcelona (HOUB). Se realizó un ensayo clínico aleatorizado, con un tamaño muestral de 93 implantes (31 de conexión externa y 62 de conexión interna: 33 con diseño para colocación infracrestal y 29 crestal) colocados en 27 pacientes. Se realizaron controles radiológicos el día de la colocación de implantes, al mes y durante la realización de las coronas, también se tuvo en cuenta el Análisis de Frecuencia de Resonancia (AFR) el día de la colocación del implante, cuando se colocó el pilar de cicatrización y durante la realización de la prótesis.
APA, Harvard, Vancouver, ISO, and other styles
6

Chou, Laisheng. "Effects of substratum surface chemistry and topography on extracellular matrix gene expression." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1997. http://www.collectionscanada.ca/obj/s4/f2/dsk3/ftp04/nq25033.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Barbosa, Gabriella Lopes de Rezende 1988. "Mensurações verticais para planejamento de mini-implantes palatinos em telerradiografia em norma lateral e tomografia computadorizada de feixe cônico." [s.n.], 2012. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290131.

Full text
Abstract:
Orientador: Solange Maria de Almeida
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-20T06:56:36Z (GMT). No. of bitstreams: 1 Barbosa_GabriellaLopesdeRezende_M.pdf: 1476954 bytes, checksum: 655317fdf41b3d0e2548c438c0fe7358 (MD5) Previous issue date: 2012
Resumo: Os objetivos deste estudo foram comparar as mensurações lineares referentes à altura óssea palatina na região de primeiros pré-molares superiores para inserção de miniimplantes palatinos por meio de imagens de telerradiografia em norma lateral (TNL), tomografia computadorizada de feixe cônico (TCFC) e telerradiografia reconstruída do exame tomográfico (telerradiografia virtual); assim como comparar as alturas ósseas das regiões medianas e paramedianas do sítio avaliado. Para tanto, foram utilizadas 110 imagens de TNL, telerradiografia virtual e TCFC, dos mesmos pacientes. Para avaliação das alturas nas imagens, foi realizada mensuração da distância entre a intersecção do longo eixo do primeiro pré-molar com o assoalho do palato duro e o assoalho nasal, a qual correspondeu à dimensão do osso disponível para inserção de mini-implantes de ancoragem. Para avaliação das alturas medianas e paramedianas no corte tomográfico na região de primeiro pré-molar, foram realizadas mensurações da distância entre a camada cortical do assoalho nasal e a cortical do palato duro nos sítios central, 3 mm à direita e à esquerda, 6 mm à direita e à esquerda. As mensurações foram realizadas por três avaliadores. Os valores encontrados da TNL não diferiram estatisticamente (p>0,05) da TCFC (padrão-ouro), sendo comparáveis aos do exame tomográfico. Já os valores da telerradiografia virtual diferiram estatisticamente (p<0,05) tanto da TCFC quanto da TNL, sendo medidas subestimadas quando comparadas ao padrão-ouro e à técnica radiográfica. Quando comparadas as medidas dos sítios avaliados, não houve diferença estatística (p>0,05) entre as alturas paramedianas e a central. Concluiu-se que as mensurações realizadas para planejamento de inserções de mini-implantes palatinos na região dos primeiros prémolares são comparáveis nos exames de TNL e em reconstruções multiplanares de TCFC, e subestimadas nos exames de telerradiografia virtual. Concluiu-se também que as regiões paramedianas bilaterais a 3mm e 6mm da sutura palatina na região avaliada possuem altura óssea comparável à região mediana do palato
Abstract: The aims of this study were to compare linear measurements related to the palatal bone thickness in the region of first premolars to insert palatal mini-implants on images of conventional lateral radiography (CLR), cone beam computed tomography (CBCT) and reconstructed radiography from CBCT scan (virtual radiograph), as well as compare the thickness of the bone regions of the median and paramedian site assessed. For this purpose, 110 images of CLR, virtual radiography and CBCT of the same patient were used. To evaluate the thicknesses on the images, measurements was performed between the distance of the intersection of the long axis of the first premolar to the hard palate floor and nasal floor, which corresponded to the relevant dimension of available bone for insertion of mini-implants. To evaluate the thickness in median and paramedian regions on CT slice in the region of first premolar, measurements were made between the cortical layer of the nasal floor and hard palate, on central site and paramedian sites 3 mm and 6 mm bilaterally. The measurements were performed by three evaluators. The values found on TNL were not statistically different (p> 0.05) of CBCT (gold standard).The values of the virtual radiography were statistically different (p <0.05) from CBCT and TNL, being underestimated when compared to the gold standard and the radiographic technique. When comparing the measurements of the sites studied, there was no statistical difference (p> 0.05) between the thicknesses of the central site and paramedian sites. It was concluded that the measurements made for planning palatal mini-implants, at the level of the first premolars, is comparable on TNL and multiplanar reconstructions of CBCT, while underestimated in virtual radiography examinations. It is also concluded that the bilateral paramedian regions at 3mm and 6mm from the palatal suture, in the region evaluated, have bone thickness comparable to the median region of the palate
Mestrado
Radiologia Odontologica
Mestre em Radiologia Odontológica
APA, Harvard, Vancouver, ISO, and other styles
8

Vasconcelos, Laércio Wonhrath [UNESP]. "Avaliação clínica e da freqüência de ressonância, de implantes instalados por meio de técnica cirúrgica modificada na maxila e submetidos à função imediata." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/103321.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-03Bitstream added on 2014-06-13T19:43:11Z : No. of bitstreams: 1 vasconcelos_lw_dr_araca.pdf: 3387652 bytes, checksum: 665ddeee618bbda24e7caff661ab090e (MD5)
Universidade Estadual Paulista (UNESP)
Brånemark et al. (1969) introduziram os implantes osseointegrados como forma de ancoragem para próteses com intuito de substituir os dentes perdidos, tanto na mandíbula como na maxila. Desde então, foram instituídas modificações no protocolo clássico. Entre elas, a submissão dos implantes à função imediatamente após a sua instalação. Esse procedimento tem sido largamente estudado na mandíbula, com altos índices de sucesso, contudo, a literatura é escassa quanto à aplicação desta técnica na maxila. Propôs-se, então, avaliar a função imediata em implantes instalados em maxilas desdentadas totais, no momento da cirurgia e após seis e 12 meses de função. Para tanto foi utilizada uma técnica cirúrgica modificada e a avaliação da estabilidade dos implantes foi feita por meio da análise da freqüência de ressonância. Foram selecionados 10 pacientes, nos quais foram instalados seis implantes na maxila com a submissão dos mesmos à função imediata mediante a instalação de uma prótese fixa, com infra-estrutura metálica, 24 horas após a cirurgia. Estes pacientes foram acompanhados por um período de 12 meses. As medidas da estabilidade do implante foram realizadas no momento da instalação dos implantes (M0) e após seis (M6) e 12 meses (M12). Após o período de acompanhamento, foram obtidos índices de sucesso de 95% para os implantes e 90% para as próteses. Quanto aos valores da estabilidade dos implantes, foi observada uma diferença estatisticamente significativa entre os valores de M0 e M6, e, M0 e M12. Sendo o M0, o momento com maior valor do coeficiente de estabilidade. Não houve diferença estatisticamente significativa entre os valores da estabilidade obtidos no M6 e M12. Quando comparados, o valor da estabilidade para cada implante, não apresentaram diferença estatisticamente significativa no mesmo período de avaliação...
Brånemark et al. (1969) presented the osseointegrated implants as a way to anchorage prosthesis for missing teeth substitution in the jaws. Ever since, modifications in the classical protocol were instituted. Among them, the functional loading of the implants, immediately after their installation. This procedure have been well documented in mandibles, with high success levels, however, literature is scarce about the application of this technique in maxilla. The purpose of this study is to evaluate the immediate function in implants installed in totally edentulous maxillas, at the surgical moment and after six and 12 months of function. For so much, a modified surgical technique was used and implant stability was evaluated through the resonance frequency analysis. Ten patients were selected, who received six implants installed in the maxilla and submitted to immediate function. A metallic infra-structure fixed prosthesis was installed 24 hours after the surgery. The follow-up period was of 12 months. Implant stability measurements were taken at the surgical moment (M0) and after six (M6) and 12 months (M12). After the follow-up period, success rates of 95% for implants and 90% for prosthesis were achieved. As for the implant stability values, significant statistical difference were observed between M0 and M6, and M0 e M12, and no significant statistical difference was observed between M6 and M12. When the stability values of each implant was compared, no significant statistical difference was observed between them for different evaluation periods. It is concluded that the submission of implants, installed in the maxilla through a modified technique, to immediate function is a well predictable procedure, ever since well selected and executed. The resonance frequency analysis is an efficient method for the evaluation of the initial and late implants’ stability.
APA, Harvard, Vancouver, ISO, and other styles
9

Santiago, Junior Joel Ferreira [UNESP]. "Avaliação da influência de diferentes materiais oclusais na confecção de próteses fixas implantossuportadas unitárias com diferentes diâmetros dos implantes osseointegrados: estudo pelo método dos elementos finitos tridimensionais." Universidade Estadual Paulista (UNESP), 2010. http://hdl.handle.net/11449/93588.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:26:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-25Bitstream added on 2014-06-13T19:34:21Z : No. of bitstreams: 1 santiagojunior_jf_me_araca.pdf: 4599975 bytes, checksum: efdcd7bb205ee8146a6d5463f80ff100 (MD5)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
A literatura científica ainda é escassa em relação à influência de diferentes materiais na confecção de próteses fixas implantossuportadas unitárias em relação aos diferentes diâmetros dos implantes osseointegrados na distribuição das tensões; as suas manifestações e repercussões na prática clínica ainda não estão totalmente esclarecidas, sendo a fundamentação científica indispensável. Assim, o objetivo desta dissertação foi avaliar a influência do material de revestimento oclusal na confecção de prótese fixa implantossuportada unitária com diferentes diâmetros de implantes osseointegrados. Para o estudo foram elaborados 08 modelos, representando cada qual uma secção de osso mandibular (osso esponjoso e cortical), com a presença apenas de um implante (Conexão Master Screw, Sistemas de Próteses, São Paulo, Brasil) do tipo hexágono externo de 3.75 mm x 10 mm (4 modelos) e de 5.00 mm x 10 mm (4 modelos) com coroas de porcelana feldspática, ou de resina acrílica, ou de resina composta ou coroa liga de NiCr. Para confecção dos modelos foram utilizados os programas de desenho assistido: Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA) e SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA). Os desenhos tridimensionais foram exportados para o programa de elementos finitos NEI Nastran® 9.0 (Noran Engineering, Inc, EUA), para geração da malha, aplicação da carga e análise. Os resultados foram visualizados através dos mapas de tensão von Mises de cada modelo proposto, a fim de avaliar as variações individuais da distribuição das tensões no implante e na coroa; no osso os resultados foram visualizados através dos mapas de tensão máxima principal. Na carga axial (200 N), o osso cortical não mostrou grandes diferenças entre todos os modelos e o osso trabecular sofreu um aumento das tensões por tração...
The scientific literature is still scarce about the influence of different veneering materials used in fabricating superstructures for implant-retained fixed prostheses in relation to different implant diameters on stress distribution, and the manifestations and implications in clinical practice were not clarified. The aim of this dissertation was to evaluate the influence of occlusal material for single implant-supported fixed prostheses with different implant diameters. For this study were simulated 8 models, representing a section of the mandibular bone (trabecular and cortical bone) with a single external hexagonal implant (Master Screw, Conexão Sistema de Prótese ltda., Sao Paulo, Brazil) of 3.75 x 10 mm (4 models) and 5.00 mm x10 mm (4 models) with a crown with different occlusal materials: feldspathic porcelain crowns, or acrylic resin or composite resin crown or NiCr alloy. The models were designed using computer-aided design softwares : Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp., Massachusetts, USA). The three-dimensional designs were exported to the finite element program NEI Nastran® 9.0 (Noran Engineering, Inc, USA) for mesh generation, load application and analysis. The results were visualized through von Mises stress maps of each model, to assess individual variations of the stress distribution on the implant and crown; bone results were visualized through maps of maximum principal stress. In axial loading (200 N), cortical bone showed no significant differences in all models,on the trabecular bone the tensile stress increased, with regular implant diameter. For non-axial loads (100 N), the cortical bone, the tensile stress increased significantly on the side common the load application, when it reduced the implant diameter; in the trabecular bone showed seemed stress patterns, although more... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
10

Bacchi, Ataís 1986. "Influência do material de infraestrutura e do desajuste vertical de próteses parciais fixas implantossuportadas nas tensões transmitidas às estruturas protéticas e ao tecido ósseo peri-implantar." [s.n.], 2012. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288548.

Full text
Abstract:
Orientador: Rafael Leonardo Xediek Consani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-19T19:18:16Z (GMT). No. of bitstreams: 1 Bacchi_Atais_M.pdf: 865962 bytes, checksum: 55e25bc8a48c9b1870a41c704082365a (MD5) Previous issue date: 2012
Resumo: O objetivo neste estudo foi avaliar a influência do material de infraestrutura e diferentes níves de desajuste vertical na concentração de tensões em prótese parcial fixa implantossuportada (infraestrutura e porcelana de cobertura), parafuso de retenção e tecido ósseo peri-implantar durante o assentamento protético e frente à aplicação de carga oclusal. Um modelo tridimensional de elementos finitos de uma porção posterior de mandíbula contendo dois implantes osseointegrados nas posições de segundo pré-molar e segundo molar, suportando uma prótese parcial fixa foi construído utilizando software específico de modelagem (SolidWorks 2010). Modelos de elementos finitos foram obtidos pela importação do modelo sólido ao software de simulação mecânica (ANSYS Workbench 11). Os modelos foram separados em grupos de acordo com o material de infraestrutura (liga de ouro tipo IV, liga de prata-paládio, titânio comercialmente puro, liga de cobalto-cromo ou zircônia) e o nível de desajuste vertical (10 ?m, 50 ?m e 100 ?m) criado na interface prótese-implante do segundo pré-molar. A concentração de tensões foi avaliada nas seguintes condições: (1) assentamento protético; e (2) cargas oclusais simultâneas de 110 N vertical e 15 N horizontal em cada dente. Os resultados obtidos mostraram que as infraestruturas mais rígidas apresentam maior concentração de tensões internas; entretanto, promoveram menores concentrações de tensão sobre a porcelana de recobrimento, em ambas condições avaliadas. Na análise do assentamento protético, materiais mais rígidos para infraestruturas aumentaram os valores de tensão no parafuso de retenção e não causaram diferença relevante nas tensões no tecido ósseo peri-implantar. Quando a carga foi aplicada, o uso de infraestruturas mais rígidas promoveu redução de tensões no parafuso de retenção e no tecido ósseo peri-implantar. Em ambas condições avaliadas um considerável aumento na concentração de tensões foi obsevado em todas as estruturas com a amplificação do desajuste. Nas diferentes simulações, o material de infraestrutura exerceu considerável influência nas tensões transmitidas às estruturas avaliadas, exceto ao tecido ósseo peri-implantar em condições de assentamento. Aumento de tensões em todas as estruturas pode ser observado com o aumento do desajuste
Abstract: The aim in this study was to evaluate the influence of the framework material and vertical misfit on the stresses created in an implant-supported partial prosthesis (framework and porcelain veneer), retention screw and peri-implant bone tissue during the settlement of the prosthesis and under load conditions. A 3-D Finite Element model of a posterior part of a jaw with two osseointegrated implants at the place of the right second pre-molar and second molar supporting an implant-supported fixed partial prosthesis was constructed using specific modeling software (SolidWorks 2010). Finite element models were obtained by importing the solid model into mechanical simulation software (ANSYS Workbench 11). The models were divided into groups according to the framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy or zirconia) and vertical misfit level (10 ?m, 50 ?m and 100 ?m) created at the second pre-molar implant-prosthesis interface. The stress concentration was evaluated in the following conditions: (1) settlement of the prosthesis; and (2) simultaneous loads of 110 N vertical and 15 N horizontal in each tooth. The obtained results showed that stiffer frameworks presented higher stress concentrations in it and led to lower stresses in the porcelain veneer, in both conditions. In the analysis of settlement of the prosthesis, stiffer framework materials increased the stress values in the retention screw and did not cause a relevant difference in the stresses values in peri-implant bone tissue. When the load was applied, the use of more stiffness frameworks led to lower stresses in the retention screw, and peri-implant bone tissue. In both conditions evaluated, considerable raise of stress concentration was observed in all the structures within misfit amplification. Comparing the results of the different simulations, the framework materials presented a considerable influence on the stress concentration in the structures evaluated, except on the peri-implant bone tissue during the settlement of the prosthesis, while a considerable increase of the stress in all the structures was observed with the increase of the misfit
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
11

Ayub, Karen Vaz. "Avaliação clínica e radiográfica de implantes utilizados como pilares de próteses inferiores implantossuportadas do tipo protocolo, colocadas sob carga imediata, empregando dois sistemas reabilitadores após 7 anos." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/25/25146/tde-03122013-164207/.

Full text
Abstract:
Esta pesquisa avaliou o sucesso de implantes utilizados como pilares de próteses inferiores implantossuportada do tipo protocolo, empregando dois sistemas reabilitadores, sob carga imediata, após 7 anos. Foram pesquisados os seguintes aspectos: índices de placa e de sangramento, estabilidade dos implantes por frequência de ressonância (FR) e perda óssea marginal. Foram avaliados 76 implantes, em 19 pacientes, divididos em 2 grupos: A (n=12, All-on-four® - Nobel Biocare®) e B (n=7, Neopronto® - Neodent®). Os pacientes foram acompanhados nos momento da instalação dos implantes (inicial), 6 meses, 1, 2 e 7 anos após a instalação. Os resultados mostraram uma taxa de sucesso de 100% para os implantes do grupo A e de 90% para o grupo B. Os índices de placa não apresentaram diferenças estatisticamente significativas e foram, no grupo A, de 71,87%, 63,54% e 47,92%, e, no grupo B de 26,78%, 41,07% e 37,50%, para as avaliações de 1, 2 e 7 anos, respectivamente. O índice de sangramento para o grupo A foi de 43,75%, 42,71% e 43,75% e para o grupo B foi de 53,57%, 51,79% e 48,21%, nos tempos de avaliação de 1, 2 e 7 anos, respectivamente, sem diferenças estatísticas. Não foi observado supuração em nenhum tempo de avaliação. Os resultados de FR não diferiram estatísticamente entre os dois grupos, entretanto, diminuíram entre a avaliação inical (grupo A = 69,27ISQ e grupo B = 68,29ISQ) e de 6 meses (grupo A = 64,65ISQ e grupo B = 66,50ISQ), e aumentaram nos anos seguintes para os 2 grupos, sendo para o grupo A de 66,17ISQ, 66,05ISQ e 69,87ISQ e para o grupo B de 67,78ISQ, 68,13ISQ e 73,61ISQ para os tempos de 1, 2 e 7 anos, respectivamente. Em relação a perda óssea, existiu diferença significativa entre grupos e foi de 0,49mm e 0,67mm após 1 ano e de 1,03mm e 1,27mm, após 7 anos, para os grupos A e B, respectivamente. Em relação à posição dos implantes, o grupo B apresentou diferença estatística entre os implantes centrais e distais nas avaliações de FR e perda óssea. Concluiu-se que 1- a taxa de sucesso foi de 100% para o grupo A e de 90% para o grupo B; 2- os índices de placa e de sangramento diminuíram ao longo dos anos de avaliação; 3- a FR foi semelhante entre os grupos, mas com diferença significativa no grupo A para o critério tempo e, no grupo B para os critérios tempos de avaliação e posição dos implantes; 4- perda da altura da crista óssea foi diferente significativamente entre os grupos, sendo maior no grupo B.
This study evaluated the success of implants used to support mandibular complete full-arch fixed prosthesis employing two rehabilitation systems with immediate loading after 7 years. The following aspects were investigated: plaque and bleeding index, implant stability by resonance frequency analysis and marginal bone loss. The 76 implants were evaluated in 19 patients divided in 2 groups: A (n=12, All-on-four® - Nobel Biocare®) and B (n=7, Neopronto® - Neodent®). The follow-up visits were at the time of implant placement (initial), 6 months, 1, 2 and 7 years after surgery. The results showed a success rate of 100% for implants in group A and 90% for group B. The plaque index did not differ statistically signifcant and were in group A, 71.87%, 63.54% and 47.92%, and in group B 26.78%, 41.07% and 37, 50% for 1, 2 and 7 years of follow-up, respectively. The bleeding index for group A was 43.75%, 42.71% and 43.75% and for group B was 53.57%, 51.79% and 48.21%, for 1, 2 and 7 years of follow-up, respectively, no statistical differences. Suppuration was not observed at any time of evaluation. The results of FR did not differ significantly between groups, however, decreased between initial (group A = 69,27ISQ and group B = 68,29 ISQ) and 6 months (group A = 64,65ISQ and group B = 66,50ISQ), and increased in the following evaluations for both groups, in group A was 66,17ISQ, 66,05ISQ and 69,87ISQ and group B was 67,78ISQ, 68,13ISQ and 73,61ISQ for 1, 2 and 7 years of follow-up, respectively. In relation to bone loss, a significant difference existed between groups and was 0,49mm and 0,67 mm after 1 year and 1,03mm and 1,27mm after 7 years, for groups A and B, respectively. Regarding the position of the implants, group B showed statistical difference between the central and distal implants for FR and bone loss. It was concluded that 1- Success rate was 100% for group A and 90% for group B; 2 - Plaque and bleeding index decreased over the follow-up; 3- FR was similar between groups, but with a significant difference in group A for thw criterion time, and in group B for the criteria evaluation times and position of the implants, 4- bone loss was significantly different between groups, and higher in group B.
APA, Harvard, Vancouver, ISO, and other styles
12

Antenucci, Rosse Mary Falcón [UNESP]. "Análise das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexões e qualidade óssea: estudo pelo método dos elementos finitos tridimensionais." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/105562.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-02Bitstream added on 2014-06-13T19:24:18Z : No. of bitstreams: 1 antenucci_rmf_dr_araca.pdf: 994627 bytes, checksum: 0fe6227d507931e16135dd308b4ca65c (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Um aspecto crítico que afeta o sucesso ou falha de um implante é a maneira pela qual as tensões são transferidas do implante ao tecido ósseo. A sobrecarga na prótese dentária pode levar a perda da osseointegração, dessa forma, é aconselhável evitar altas concentrações de tensões no osso de suporte, do ponto de vista clínico. Entretanto, o estresse mecânico pode ter consequências positivas ou negativas no tecido ósseo, fatores esses dependentes de vários fatores associados que podem ser mecânicos ou biológicos. Portanto, o propósito do presente estudo foi analisar a influência da qualidade óssea na distribuição das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexão protética, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados doze modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco com diferentes qualidades ósseas (Tipo I, II, III e IV) e a presença de um implante (4,0x10 mm) com diferente tipo de conexão (Hexágono externo, interno e cone Morse), com coroa metalo-cerâmica. Após geração de geometrias, os modelos foram importados para o programa de pré e pós processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (4 para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos...
A critical issue that affects the success or failure of an implant is the manner in which the stresses are transferred from the implant to bone tissue. The overload can lead the dental implant to loss of osseointegration, thus it is advisable to avoid high stress concentrations in bone support, according to the clinical point of view. However, mechanical stress can bring positive or negative consequences in the bone tissue and these factors depend on association with mechanical or biological factors. Therefore, the purpose of this study was to analyze the influence of bone quality on stress distribution in implant-prosthesis unit with different types of prosthetic connection, by the three-dimensional finite element method. For this, twelve three-dimensional models were made with the aid of SolidWorks 2010 and Rhinoceros 4.0, graphical modeling software, besides the InVesalius. Each model was composed of a block with different bone qualities (Type I, II, III and IV), an implant (4.0 x 10 mm) with different type of prosthetic connection (Hexagon external, internal and Morse taper) and metal ceramic crown. After generation of geometries, the models were imported into FEMAP 10.2, the pre and post-processing finite element software, where it was generated finite element meshes, boundary and loading conditions. The 200N load was applied axially and 100N obliquely on the occlusal surface of crowns. This total load was divided among the cusps (four points for the axial load and two points for the oblique load on the lingual cusps). Then, the analysis was generated in the FEMAP 10.2 and exported to the NeiNastran version 9.2 software for calculation in finite element analysis, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
13

Rahmanivahid, Pooyan. "Investigation on influence of dental implants." Thesis, Brunel University, 2015. http://bura.brunel.ac.uk/handle/2438/13789.

Full text
Abstract:
Osseointegration is defined as the direct physical and practical relation between the living tissue and implant surface. Although, success rate of dental implants is high, implant failure occurs. Overloading implants from occlusal forces are known as one of the main reasons. In order to have successful implant, a dynamic balance must be provided between mechanical and biological elements (Isidor, Flemming 1996). Şimşek et al. reported bone quality, oral sanitation, host medical condition and biomechanical parameters as the main reasons for implants failure. Also, implant fixture micromotion and inappropriate stress in the bone implant interface is known as the potential reasons for early bone loss and implant failure (Şimşek, Barış 2006). Even so, implant position in jawbone, bone density; biomaterial properties of implant surface, treatment technique, loading history and patient clinical status are the influential factors in implant success (Brunski, J.B. 1999). Although there are many studies on stress distribution of implants in bone-implant interface, majority are limited to current implants in the market. However, current designs have been developed by marketing purposes rather than scientific considerations. Therefore, there is need to introduce and analyse new designs in order to optimize implant structure. Recent investigations have shown reliability of FEA method in simulating human jawbone situation. This research aims to develop a new dental implant with better life expectancies and introduce an optimized implant based on FEA stress analyses and experimental tests. Therefore, based on literature recommendations a series of new design factors are defined and analysed. In this study, a primary design is created in AutoCAD and yields to 3 different implants developed in SolidWorks. Branemark MK IV was selected as the bench model to play role of control group. Then, CT-scan images of human jawbone are imported to MIMICS to create a host bone model. Implant and jawbone models are assembled in 3-Matic and exported to Abaqus for final analyses. A series of loadings are defined to examine implant performance in different conditions. Branemark and C-3 implants are manufactured from Titanium for experimental analyses. Mechanical tests on sawbone foam blocks and cadavers are targeted to portray realistic performance. This research demonstrates C-3 model as the optimized dental implant, which presents a new design profile and better performance in low bone densities. The FEA and experimental results validate the benefit of the new design compare to the conventional ones. Furthermore, results can provide a basis for future designers to develop further optimizations.
APA, Harvard, Vancouver, ISO, and other styles
14

Welander, Maria. "Soft tissue integration to dental implants /." Göteborg : Deptartment of Periodontology, Institute of Odontology, The Sahlgrenska Academy at University of Gothenburg, 2008. http://hdl.handle.net/2077/18196.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

O'Sullivan, Dominic. "The effect of implant geometry upon the primary stability of dental implants." Thesis, University of Bristol, 2001. http://hdl.handle.net/1983/339010c1-63ee-4eb9-b03c-b3a2b9b89dbf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
16

Caneva, Marco [UNESP]. "Influência de implantes pós-exodônticos com diferentes configurações sobre os tecidos peri-implantares: estudo experimental em cães." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/103315.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-05Bitstream added on 2014-06-13T21:04:26Z : No. of bitstreams: 1 caneva_m_dr_araca.pdf: 5420643 bytes, checksum: 2a88c9a9a85203bfd0cd8f4fd62affa4 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Objetivo: avaliar a influência da instalação de implantes em alvéolos imediatamente após a extração do elemento dental na regeneração dos tecidos peri-implantares com implantes de diferentes configurações Material e métodos: Nos alvéolos distais dos quartos pré-molares mandibulares de cães, imediatamente após as extrações das raízes dentais, foram instalados implantes cilíndricos com 3,3 mm de diâmetro (grupo controle) e implantes cônicos com 5,0 mm de diâmetro (grupo teste). Foram avaliados histologicamente a regeneração dos tecidos duros e moles peri-implantares após 4 meses do procedimento cirúrgico. Resultados: Todos os implantes apresentaram-se osseointegrados ao tecido ósseo maduro mineralizado. A crista óssea alveolar sofreu reabsorção tanto no grupo teste como controle. A superfície óssea vestibular dos implantes do grupo teste (cônico; 3,6 mm) apresentou maior grau de reabsorção em comparação ao grupo controle (cilíndrico; 1,6 mm). As dimensões dos tecidos moles apresentaram-se semelhantes em ambos os grupos. No entanto, em relação ao ombro do implante, a mucosa peri-implantar localizou-se mais apicalmente no grupo teste em relação ao grupo controle. Conclusão: Este estudo confirmou que a distância entre a superfície do implante e o contorno externo da crista óssea alveolar vestibular influenciou no grau de reabsorção da tábua óssea vestibular. Conseqüentemente, em relação ao ombro do implante, a mucosa peri-implantar será estabelecida em um nível mais apical, se a distância entre a superfície do implante e o contorno externo da crista óssea alveolar for menor
Aim: the aim of the present experiment was to study the influence of implant installation into sockets immediately after tooth extraction on the healing periimplant tissues with implants of various configurations. Material & methods: Transmucosal cylindrical 3.3mm in diameter implants in the control sites, and conical 5.0mm in diameter in the test sites, were installed into the distal socket of the forth mandibular premolars in dogs immediately after tooth extraction. After 4 months, the hard and soft tissue healing was evaluated histologically. Results: All implants were integrated in mineralized mature bone. Both at the test and control sites, the alveolar crest underwent resorption. The buccal bony surface at the implant of the test sites (conical; 3.6mm) was more resorbed compared to the control sites (cylindrical; 1.6mm). The soft tissue dimensions were similar in both groups. However, in relation to the implant shoulder, the periimplant mucosa was located more apically at the test compared to the control sites. Conclusion:The present study confirmed that the distance between the implant surface and the outer contour of the buccal alveolar bony crest influenced the degree of resorption of the buccal bone plate. Consequently, in relation to the implant shoulder, the peri-implant mucosa will be established at a more apical level if the distance between the implant surface and the outer contour of the alveolar crest is small
APA, Harvard, Vancouver, ISO, and other styles
17

Perez, Miguel Angel Jaimes. "Influencia do desenho dos implantes endosseos na distribuição de tensões apos aplicação de cargas verticais e obliquas : analise estrutural e fotoelastica." [s.n.], 2008. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289425.

Full text
Abstract:
Orientador: Jose Ricardo de Albergaria Barbosa
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-11T23:04:29Z (GMT). No. of bitstreams: 1 Perez_MiguelAngelJaimes_M.pdf: 6909101 bytes, checksum: 41413f644c388e8bd46795ab371670ee (MD5) Previous issue date: 2008
Resumo: Este estudo teve como objetivo analisar a influência do desenho dos implantes endósseos na distribuição de tensões geradas nos modelos fotoelásticos após aplicação de cargas verticais e oblíquas a 7,5N, em quatro marcas comerciais de implantes endósseos. Foram selecionados doze implantes, divididos em quatro grupos: I.) Máster Conect Cônico1 4,3 x 13 mm; II.)Titamax Ti Medular2 3,75 x 13 mm; III.) Colosso3 RC 4,0 x 13mm; IV.) Bicon Uncoated Implant4 3,5 x 11mm, cada grupo contendo 3 implantes da mesma marca comercial. Através da Microscopia Eletrônica de Varredura foi analisado o desenho estrutural dos implantes. Para a análise da distribuição de tensão foram confeccionados oito modelos em resina fotoelástica com dimensões de 40 mm x 10 mm de base e 30 mm de comprimento. Dois implantes para cada grupo foram posicionados e fixados no interior dos modelos fotoelásticos. Uma vez verificada a ausência de tensões nos oito modelos foram iniciados os ensaios. Quatro modelos dos diferentes grupos receberam cargas verticais e quatro receberam cargas oblíquas de 7,5N. Por meio do polariscópio circular pertencente ao laboratório de Materiais Dentários e Prótese da USP-Riberão Preto, foi possível visualizar as franjas de tensões geradas nos modelos. Cada seqüência foi fotografada, sendo mantida a mesma distância focal em todos os ensaios. Os resultados obtidos foram analisados por grupos. O Grupo I, implante de hexágono interno longo com porção cervical polida, topo das roscas arredondadas, passos das roscas contínuas, espirais angulados e configuração cônica, apresentou concentração das tensões na região apical, quando submetida à carga vertical e oblíqua. O Grupo II, implante de hexágono externo, porção cervical polida, topo das roscas em forma de "v", passos das roscas contínuos, espirais anguladas e configuração cilíndrica, apresentou distribuição das tensões na região apical, médio e cervical do implante quando submetida à carga vertical e oblíqua. O Grupo III, implante com hexágono interno, porção cervical polida, topo das roscas em forma cônica, passos das roscas contínuos, espirais anguladas e configuração cilíndrica, apresentou distribuição das tensões nas regiões apical, médio e cervical do implante após aplicação de carga vertical e oblíqua. O Grupo IV, implante com sistema cone morse, ombro cervical inclinado, platô ou barbatanas, topo do platô quadradas, passos do platô descontinuais, e configuração cilíndrica, distribuiu as tensões nas regiões apical, médio e cervical do implante após aplicação de carga vertical e oblíqua. Baseado nos resultados obtidos e dentro da metodologia deste estudo conclui-se que: O grupo I, de configuração cônica concentrou a distribuição das tensões em região apical. Os grupo II, III e IV, de configuração cilíndrica, distribuíram as tensões com intensidade e localização similares nos terços apical médio e cervical. O presente estudo evidenciou haver diferenças na distribuição das cargas de um tipo de implante para outro, levando acreditar que essas diferenças possam ter relação com o desenho das roscas e platô.
Abstract: The meaning of this study was analyze on 4 dental implants brands the influence of its thread design on tensions distribution generated thru photoelastic models, after applying a 7.5N load on vertical and oblique directions. Twelve implants, organized in four groups had been selected: I.) Máster Conect Cônico1 4.3 x 13 mm; II.) Titamax Ti Medular2 3.75 x 13 mm; III.) 4,0 Colosso3 RC x 13mm; IV.) Bicon Uncoated Implant4 3.5 x 11mm, being in each group, three dental implants of the same commercial brand. The structural designs of the implants were analyzed with Electronic Microscopy Sweepings. For the tension distribution analysis, eight models had been confectioned in photoelastic resin with 40mm x 10mm base dimensions and 30 mm of length. Two implants of each group had been located and fixed in the interior of photoelastic models. Once verified the absence of tensions in the eight models the analysis were started. Four models of the different groups had received 7.5N load on vertical and four received this same load on oblique direction. By means of the circular polariscope developed in the Dental Materials and Prostheses laboratory the Ribeirão Preto Dental School (USP/RP), it was possible to visualize the tensions fringes generated in the models. Each sequence was photographed, being kept the same focal distance in all the assays. The gotten results had been analyzed by groups. Group I., implants with long internal hexagon and polishing cervical portion, top of rounded off threads, angled steps of continuous threads, spirals and conical configuration, presented tensions concentration on the apical region, when submitted to the vertical and oblique load. Group II, implants with external hexagon, polishing cervical portion, top of threads in form of v, angled steps of continuous threads, spirals and cylindrical configuration, presented tensions distribution on the apical, medial and cervical regions of the dental implants, when submitted to the vertical and oblique load. Group III., implants with internal hexagon, polishing cervical portion, top of threads in conical form, steps of threads continuous, spirals angled and cylindrical configuration, presented tensions distribution on the apical, medial and cervical regions . Group IV, implants with cone morse system, inclined cervical shoulder, square shaped threads, fin or plateau, angled plateau steps discontinuous, and cylindrical configuration, distributed the tensions on the apical, medial and cervical regions after the application of vertical and oblique loads. Based in the results gotten and respecting the limitations of this study it can be concluding that: Group I. with conical configuration, the tension distributions is concentrated on the apical region. Groups II, III and IV, with cylindrical configuration, had distributed the tensions with similar intensity and localization on the apical, medial and cervical regions. In the present study it is evidenced to have differences in the distribution of loads on the dental implants analyzed, being not evident that these differences have relation with the threads design.
Mestrado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
18

Freitas, Júnior Amilcar Chagas [UNESP]. "Plataforma regular versus switching: estudo mecânico por meio de testes laboratoriais de fadiga e análise de elementos finitos em implantes com hexágono externo e interno." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/105554.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-30Bitstream added on 2014-06-13T20:25:50Z : No. of bitstreams: 1 freitasjunior_ac_dr_araca.pdf: 626707 bytes, checksum: 01bcfeff181d77eb6eaa682b52483519 (MD5)
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Proposição. O objetivo do presente trabalho foi avaliar a influência do conceito de plataforma switching na confiabilidade e modo de falha de restaurações unitárias sobre implante com hexágono externo ou interno na região anterior da maxila. Adicionalmente, análises de elementos finitos foram realizadas para avaliar o padrão de distribuição de tensão dentro do complexo pilar-implante e no tecido ósseo peri-implantar. Materiais e Métodos. 84 implantes foram divididos em 4 grupos (n = 21) para realização dos testes de fadiga: SWT-EH e REG-EH (implantes de conexão externa com plataforma switching ou regular, respectivamente); SWT-IH e REG-IH (implantes de conexão interna com plataforma switching ou regular, respectivamente). Análises estatísticas de Weibull foram realizadas considerando as missões de 50.000 ciclos a 210N e 300N. Adicionalmente, foram construídos 4 modelos de elementos finitos considerando as mesmas variáveis para obtenção das tensões equivalentes de von Mises (σvM) no complexo pilar-implante e das máximas tensões principais (σmax) no osso peri-implantar. Resultados. Os valores de Beta para os grupos SWT-EH (1,31), REG-EH (1,55), SWT-IH (1,83) e REG-IH (1,82) indicaram que a fadiga acelerou a falha em todos os grupos. Os valores de confiabilidade calculados para os grupos SWT-EH, REG-EH, SWT-IH e REH-IH foram 0,53 (0,33 - 0,70), 0,93 (0,80 - 0,97), 0,99 (0,93 - 0,99) and 0,99 (0,99 -de tensão estiveram no pilar (SWT-IH = 186 MPa e REG-IH = 88.8 MPa). No osso cortical, os implantes com plataforma switching geraram menor tensão (σmax) tanto para conexão externa (SWT-EH = 49.0 MPa e REG-EH = 56.5 MPa) como para conexão interna (SWT-IH = 37.7 MPa e REG-IH = 45.5 MPa)...
Purpose. The aim of the present study was to evaluate the effect of platform switching concept on reliability and failure modes of anterior single-unit restorations for internal and external hex implants. Additionally, finite element analysis were performed to assess the stress distribution within implant-abutment complex and peri-implant bone. Materials and Methods. 84 implants were divided in 4 groups (n=21) for fatigue tests: REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). Weibull analysis for a mission of 50,000 cycles at 300N was performed. Additionally, 4 three-dimensional finite element models reproducing the characteristics of specimens used in mechanical tests were created to evaluate the equivalent von Mises stress (σvM) within implant-abutment complex and the maximum principal stress (σmax) in the peri-implant bone. Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The calculated reliability for groups SWT-EH, REG-EH, SWT-IH and REH-IH were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), respectively. Failure modes (screw and/or abutment fracture) were similar for regular and switched-platform implants. Within implant-abutment complex, the higher peak of stress (σvM) was observed in fixation screw (SWT-EH = 190 MPa and REG-EH = 160 MPa) for groups with external hex implants; while for groups with internal hex implants was in abutment (SWT-IH = 186 MPa and REG-IH = 88.8 MPa). In the cortical bone... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
19

Olate, Morales Sergio Adrian. "Analise histologica e histomorfometrica do reparo osseo perimplantar em cães submetidos a instalação de implantes endosseos com um modelo de carga precoce em dois diferentes desenhos de implantes." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289423.

Full text
Abstract:
Orientador: Jose Ricardo de Albergaria-Barbosa
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-13T01:32:19Z (GMT). No. of bitstreams: 1 OlateMorales_SergioAdrian_M.pdf: 2518502 bytes, checksum: 379ec7fb825eca639d7e7c3aa4e052a8 (MD5) Previous issue date: 2009
Resumo: Diferentes protocolos para a reabilitação com prótese implanto assistida têm sido reportados. Deles, é possível que a carga imediata em implantes unitários sejam um dos mais controversos. O objetivo deste estudo foi estabelecer quantitativamente as características de reparo ósseo em implantes submetidos a um modelo de carga precoce. Foi desenvolvido um modelo experimental em cães para a avaliação de dois protocolos de instalação de implantes dentais com dois desenhos diferentes. Foi realizada a exodontia dos pré-molares bilaterais mandibulares dos animais e após de três meses foi realizada a instalação de dois implantes bilateriais. No implante mesial foi realizada a instalação do parafuso cicatrizador de 7 mm (modelo de carga imediata unitária sem contato oclusal) e no implante distal foi instalado o parafuso cobertor (técnica de implante submerso). Cada hemimandíbula recebeu um implante cilíndrico (Neodent Titamax CM®) e um implante cônico (Conexão Conect Ar®) com seu parafuso cicatrizador. Inicialmente os primariamente foram avaliados com microscopia eletrônica de varredura. Os sacrifícios dos animais foram após de três e seis semanas. Os blocos foram descalcificados e processados para análise com histológica descritiva e histomorfométrica. Foi aplicado o teste estatístico t teste para variáveis independentes com nível de significância de 5%. De forma geral, os implantes apresentaram maior formação óssea no nível cervical e menor no nível apical. Os resultados demonstram também maior formação óssea em implantes com o modelo de carga precoce que em aqueles sem carga, com ausência de diferença estatística. Por outra parte, os implantes cônicos apresentaram maior formação óssea que os cilíndricos, também sem significância estatística. Concluiu-se que os implantes com instalação do parafuso cicatrizador, como modelo de restauração imediata sem contato oclusal, apresenta maior quantidade óssea nos vales quando comparados aos implantes não submetidos a carga
Abstract: Several treatment types using prosthesis over implants have been reported, being the singles immediate loading therapy with more controversy. The meaning of the present study is established the characteristics of bone repair in dental implant submitted to immediate loading. It was performed a experimental model using dogs to value two different installations protocols of dental implants. It was done the extraction of the bilateral premolars of the jaw, installing the dental implants after 3 months of healing. The anterior implant was submitted to healing screw install of 7 mm (unitary immediate load model without oclusal contact) and the posterior ones were covered with cove screrw (immerse implant technique). Each hemi-jaw presented one cylindrical (Neodent Titamax CM®) or conical (Conexão Conect Ar®) with with anterior or posterior position, that was evaluated with scanning electron microscopy. The sacrifices were performed on three and six months. The specimens were decalcified and processed to begging its histological evaluation using descriptive and histomorphometric analyses. The statistical test T test was performed using significance index of 5%. In general, dental implants showed more bone formation on cervical region and less on apical area. The results demonstrated more bone formation on the immediate loading types, with no statistical significance. The conical ones presented more bone formation that cylindrical, but without statistical significance. This way it is possible to conclude that implants with immediate installation of healing screw, how immediately load model without oclusal contact (immediately restauration), have more osseous presence when compared to non load implant
Mestrado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
20

Prado, Devanir Silva Vieira 1951. "Avaliação do comportamento mecanico de proteses fixas implantossuportadas por meio da tecnica de extensometria eletrica." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290247.

Full text
Abstract:
Orientador: Wilkens Aurelio Buarque e Silva
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-13T01:38:34Z (GMT). No. of bitstreams: 1 Prado_DevanirSilvaVieira_M.pdf: 895028 bytes, checksum: fe09fdf9bad8a966f0302b161600791e (MD5) Previous issue date: 2009
Resumo: Muitas vezes, as tensões são causadas por alterações nas adaptações das estruturas protéticas ao implante, além dos desajustes marginais entre as fixações e as reabilitações protéticas. Este trabalho tem como objetivo, avaliar a distribuição de compressão e tração dos pilares protéticos e infra-estrutura metálica fundida em liga de cobalto-cromo, pela técnica de monobloco, simulando uma prótese fixa implantossuportadas sobre 06 implantes com distância de 10 mm entre implantes e com extremo livre (cantilever) bilateral com extensão de 20 mm, colocados através da curvatura da linha oclusal mandibular. Em cada pilar foram colados quatro extensômetros e um em cada cantilever, após o apertamento de todos pilares e a infra-estrutura aos implantes, foi submetido a um ensaio mecânico com cargas compressivas verticais de 150 N, analisando quantitativamente os resultados bem precisos através da extensometria. Os resultados foram obtidos usando os maiores valores de carga axial registrados em cada ponto de força aplicado, registrando deformação para infra-estrutura, pilares e os cantilevers. Com aplicação de carga nos pontos entre os pilares, foi obtido nos pilares mais próximos a aplicação da carga um maior grau de compressão e nos pilares mais distantes, em menor grau de acordo com a distribuição de carga deformação por compressão e ou/ tração. Com aplicação de carga vertical máxima no cantilever, o pilar adjacente foi o mais solicitado por compressão, independente do ponto de aplicação da carga e o último pilar do lado oposto em menor intensidade, também solicitado por compressão, formando um eixo de rotação, no qual os componentes anteriores foram solicitados em regime de tração (alavanca). O carregamento mecânico registrou deformação para a infraestrutura, pilares e cantilever.
Abstract: Frequently, stresses are caused by changes in adaptations of prosthetic structures to the implant besides marginal disajustment between prosthetic fixing and rehabilitations. This study aims to evaluate the distribution of compression and traction of the prosthetic sustainers and the methalic framework melted in cromocobalt alloy, through the monoblock technic simulating a fixed prosthesis implantsupported on 06 implants at the distance of 10mm between each other and with bilateral cantilever extending to 20mm, placed along the mandibular oclusal line curvature, with the extensometry technic. In each abutment there have been placed four strain guages and one in each cantilever, in configuration "Wheatstone Bridge", after all components having been fixed to the framework, it was submitted to a mechanic essay with vertical pressing charges of 150Ncm, checking quantitatively the accurate result through extensometry. Results have been obtained by using the greatest values of axial charge registered in each place of applied force,. On nearest pillars to the charge, It has been obtained a greater degree of compression (fulcrum), what corresponds to the amount of oclusal force applied to the equalizing stress force. And, therefore, the most distant pillars will assimilate a negative deformation ( compression) or a positive deformation (traction, seesaw), proportional to the lever arm.
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
21

Ribeiro, Fernanda Vieira. "Avaliação da regeneração ossea em defeitos peri-implantares de deiscencia tratados com uma abordagem combinada associando celulas derivadas da medula ossea e regeneração ossea guiada : estudo histomorfometrico em cães." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287911.

Full text
Abstract:
Orientadores: Marcio Zaffalon Casati, Karina Gonzales Silverio Ruiz
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-14T23:45:21Z (GMT). No. of bitstreams: 1 Ribeiro_FernandaVieira_D.pdf: 8018060 bytes, checksum: 8fc3b530db926d929facce5cfd30fb4e (MD5) Previous issue date: 2009
Resumo: O objetivo deste estudo foi avaliar histometricamente o reparo ósseo em defeitos periimplantares do tipo deiscência, criados cirurgicamente em cães, tratados com a associação de células derivadas da medula óssea (CMs) e regeneração óssea guiada (ROG). A medula óssea foi obtida a partir da crista ilíaca de oito cães beagle adultos machos. Células derivadas da medula óssea (CMs) foram isoladas, cultivadas in vitro e fenotipicamente caracterizadas com relação as suas propriedades osteogênicas. Os mesmos animais foram submetidos à extração bilateral dos primeiros molares e terceiro e quarto pré-molares inferiores. Após três meses, três leitos para a colocação de implantes foram confeccionados em cada lado da mandíbula, deiscências ósseas vestibulares foram criadas e, então, implantes de titânio de superfície usinada foram colocados. As deiscências ósseas foram tratadas aleatoriamente, de acordo com um dos seguintes grupos: 1) ROG+CMs+C: membrana de PTFE-e com reforço de titânio associada às células derivadas da medula óssea semeadas no carreador, 2) ROG+C: membrana de PTFE-e com reforço de titânio associada ao uso do carreador sem células, 3) CMs+C: células derivadas da medula semeadas no carreador, 4) ROG: membrana de PTFE-e com reforço de titânio, 5) C: carreador sem células e 6) Controle: nenhum tratamento. Após três meses, os animais foram sacrificados e os implantes em conjunto com os tecidos adjacentes foram processados laboratorialmente para obtenção de secções não descalcificadas. Os parâmetros avaliados foram: Contato direto osso-implante (CO), Preenchimento ósseo dentro das roscas do implante (PR) e Área de tecido ósseo fora das roscas (AF). In vitro, a caracterização fenotípica demonstrou que células derivadas da medula óssea apresentaram potencial osteogênico identificado pela formação de nódulos minerais e expressão de marcadores ósseos (fosfatase alcalina, sialoproteína óssea e colágeno tipo I). As análises histométricas revelaram que todos os defeitos tratados com membrana (ROG+CMs+C, ROG+C e ROG) demonstraram resultados estatisticamente similares (p>0,05) com relação à área de novo osso formado fora das roscas do implante, apresentando, no entanto, maior quantidade de osso neoformado fora dos limites das roscas, quando comparados aos demais grupos (CMs+C, C e Controle) (p<0,05). Adicionalmente, foi observado que o preenchimento ósseo dentro das roscas foi estatisticamente semelhante entre os grupos que utilizaram membrana (ROG+CMs+C, ROG+C, ROG) e o grupo tratado com células sem barreira (CMs+C) (p>0,05), enquanto todos estes grupos mostraram um preenchimento ósseo significativamente superior ao grupo Controle (p<0,05). Com relação à porcentagem de contato osso-implante, embora os defeitos tratados com membrana (ROG+CMs+C, ROG+C e ROG) tenham apresentado valores estatisticamente maiores quando comparados aos defeitos dos grupos C e Controle (p<0,05), uma tendência para aumento da extensão de contato osso-implante foi observada nos defeitos tratados com células sem a associação da ROG (grupo CMs+C). Dentro dos limites do presente estudo, pôde-se concluir que embora as células derivadas da medula óssea, utilizadas isoladamente, tenham promovido bons resultados em relação à formação óssea dentro das roscas do implante, o seu uso, associado à ROG, não promoveu benefícios adicionais na formação óssea em defeitos peri-implantares de deiscência.
Abstract: The purpose of this investigation was to histometrically evaluate the bone healing in surgically created dehiscence-type defects around titanium implants treated with an association of bone marrow-derived cells (BMCs) and guided bone regeneration (GBR). Bone marrow cells were harvested from eight male adult beagle dogs, cultured in vitro and phenotypically characterized with regard to their osteogenic properties. Following, the same animals were subjected to bilaterally teeth extraction (lower premolars and the first molar) and three months later, three implant sites were drilled in each side of mandible, buccal bone dehiscences were created and titanium dental implants with machined surface were placed. Dehiscences were randomly assigned to one of the following groups: 1) GBR+BMCs+C: PTFE-e barrier placement associated with BMCs into the carrier, 2) GBR+C: PTFE-e barrier placement associated with carrier, 3) GBR: PTFE-e barrier placement, 4) BMCs+C: BMCs into the carrier, 5) C: carrier without cells e 6) Control: no treatment. After 3 months, the animals were sacrificed and the implants in conjunction with adjacent hard tissues were processed for undecalcified sections. Bone-to-implant contact (BIC), bone filling within the limits of implant threads (BF) and new bone area (BA) in a zone lateral to the implant surface were obtained. Results: In vitro, phenotypic characterization demonstrated that BMCs presented osteogenic potential identified by the mineral nodule formation and the expression of bone markers. Histometrically, inter-group analysis demonstrated that all defects treated with GBR (GBR+BMCs+C, GBR+C and GBR) were statistically similar in terms of BA (p>0.05), presenting significantly higher BA as compared with other groups (BMCs+C, C and Control) (p<0.05). With respect the BF, no differences were observed among GBR+BMCs+C, GBR+C, GBR and BMCs+C groups (p>0.05), whereas all these groups showed statistically superior BF as compared to Control group (p<0.05). Additionally, although the percentage of BIC has been significantly higher in the defects treated by barrier membrane (GBR+BMCs+C, GBR+C and GBR) as compared to C and Control groups (p<0.05), a trend towards to a greater extension of BIC has been observed for the defects treated with BMCs+C. Within the limits of this study, it was concluded that although the use of bone marrowderived cells has provided promising outcomes in terms of bone formation within the limits of implant threads, their use, in combination with GBR, has not promoted additional benefits on the bone regeneration in peri-implantar dehiscence type bone defects.
Doutorado
Periodontia
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
22

Ricomini, Filho Antônio Pedro 1983. "Avaliação da perda de pre-carga e infiltração bacteriana em sistemas de implantes de encaixe conico e hexagono externo." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288134.

Full text
Abstract:
Orientador: Altair Antoninha Del Bel Cury
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-14T23:43:34Z (GMT). No. of bitstreams: 1 RicominiFilho_AntonioPedro_M.pdf: 1929547 bytes, checksum: 3218196794c582fbd092c07948036e16 (MD5) Previous issue date: 2009
Resumo: A presença de microrganismos na interface implante e pilar é um dos fatores associado ao insucesso de implantes osseointegrados. Sistemas de implantes de encaixe cônico visam precisa adaptação entre o implante e o pilar, entretanto não se sabe o comportamento desses sistemas frente a condições de estresse da cavidade oral quanto à manutenção da pré-carga e capacidade de selamento bacteriano. Assim, o objetivo deste estudo foi avaliar a perda de précarga e a infiltração bacteriana na interface implante e pilar de sistemas de encaixe cônico e hexágono externo, submetidos à ciclagem térmica e fadiga mecânica (CF). Foram utilizados 48 implantes de quatro sistemas de implante-pilar divididos em 8 grupos (n=6): (1) hexágono externo e munhão universal; (2) hexágono externo e munhão universal com CF; (3) cone morse e munhão universal; (4) cone morse e munhão universal com CF; (5) cone morse e munhão universal parafuso passante; (6) cone morse e munhão universal parafuso passante com CF; (7) cônica justaposição e pilar padrão; (8) cônica justaposição e pilar padrão com CF. Os implantes foram fixados em resina epóxica e os pilares acoplados, realizando a pré-carga. Os espécimes (implante-pilar) foram submetidos à ciclagem térmica de 1.000 ciclos a 5°C e 55°C, com permanência de 60 s em cada banho, e à fadiga mecânica de 1,0 milhão de ciclos, 1,0 Hz e 120 N. O ensaio de infiltração bacteriana foi realizado com o microrganismo Streptococcus sanguinis (NCTC 10904). Os espécimes foram imersos em meio Tryptic Soy + Yeast Extract (TY) contendo S. sanguinis e incubados a 37°C e 10% CO2 por 72 h. Os valores de destorque foram registrados e os pilares foram desacoplados. Cone de papel estéril foi esfregado na parte interna do implante, inserido em um tubo contendo meio TY estéril e incubado. A presença de infiltração bacteriana foi avaliada por meio da turbidez do caldo. Implantes e pilares foram avaliados por meio de MEV. Os dados de perda de pré-carga foram submetidos à análise de variância a 2 critérios e ao teste de Tukey. Todos os sistemas apresentaram maiores valores de destorque quando submetidos à CF (p<0,05). O sistema cone morse com munhão universal apresentou os maiores valores de destorque quando comparado aos demais sistemas (p<0,01). Todos os sistemas cônicos apresentaram infiltração bacteriana. Dentro das condições experimentais, o sistema cone morse com munhão universal apresentou os maiores valores de destorque e não foi observado relação entre a perda da précarga e infiltração bacteriana.
Abstract: The presence of microorganisms in the implant and abutment interface is one of the factors associated to the osseointegrated implant failures. Conical junction implant systems have aimed a precise fit between implant and abutment, however, the behavior of these systems it is not known when submitted to the stress environment as found in the oral cavity, related to the preload maintenance and bacterial seal ability. Thus, the aim of this study was to evaluate the preload loss and the bacterial penetration through the implant-abutment interface of conical and external hexagon connection systems, submitted to thermal cycling and mechanical fatigue (TM). Forty eight implants of four different implant-abutment systems were divided in 8 groups (n=6): (1) external hexagon and universal post; (2) external hexagon and universal post with TM; (3) morse taper and universal post; (4) morse taper and universal post with TM; (5) morse taper and universal post two pieces; (6) morse taper and universal post two pieces with TM; (7) locking taper and standard abutment; (8) locking taper and standard abutment with TM. The implants were embedded in epoxy resin and the abutments were connected, setting the preload. The assemblies (implant-abutment) were submitted to thermal cycling of 1.000 cycles at 5°C and 55°C, with a dwell time of 60 s each and to mechanical fatigue, 1.0 million cycles, 1.0 Hz, 120 N. Bacterial penetration assay was performed with Streptococcus sanguinis (NCTC 10904). The assemblies were immersed in Tryptic Soy + Yeast Extract (TY) broth containing S. sanguinis and incubated at 37°C and 10% CO2 for 72 h. Detorque values were recorded and the abutments were disconnected. Sterile paper points were rubbed on the inner part of the implant and inserted in a tube with sterile TY broth and incubated. The presence or absence of bacterial penetration was assessed by the broth turbidity. Implants and abutments were observed by SEM. The preload loss data was analyzed by two-way ANOVA, followed by Tukey test. All the screw systems showed higher detorque values when submitted to TM(p<0,05). The morse taper system with universal post showed the highest detorque values when compared with the other systems (p<0,01). All the conical systems showed bacteria penetration. Within these experimental conditions, the morse taper system with universal post showed the higher detorque values and no relation between the preload loss and the bacterial penetration was observed.
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
23

Lima, Liana Linhares. "Efeito da aplicação intermitente do PTH (1-34) sobre o tecido osseo ao redor de implantes inseridos em ratas expostas ou não a fumaça de cigarro." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287910.

Full text
Abstract:
Orientadores: Marcio Zaffalon Casati, João Batista Cesar Neto
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-15T00:47:10Z (GMT). No. of bitstreams: 1 Lima_LianaLinhares_D.pdf: 1779418 bytes, checksum: 5170e97149f324c7dae9d9edd2c763fb (MD5) Previous issue date: 2009
Resumo: O objetivo do presente estudo foi avaliar histometricamente a influência do PTH (1-34) sobre o reparo ósseo e osseointegração de implantes de titânio instalados em tíbias de ratas expostas ou não à inalação da fumaça de cigarro. Foram utilizadas 61 ratas Wistar adultas aleatoriamente divididas em: grupo 1 (n=15) : animais que receberam a aplicação do veículo necessário para a dissolução do hormônio após a instalação do implante; grupo 2 (n=16) : inalação de fumaça de cigarro (IFC) por 60 dias no pré e pós-operatório da colocação do implante; grupo 3 (n = 17): tratamento do grupo 2 associado à injeções subcutâneas de 40 fxg/kg de PTH sintético (1-34) três vezes por semana, após a colocação do implante e grupo 4 (n=13) : injeções subcutâneas de 40 Hg/kg de PTH sintético (1-34) três vezes por semana após a instalação dos implantes. Os animais foram sacrificados sessenta dias após a colocação dos implantes, secções não descalcificadas foram obtidas e avaliadas histometricamente, segundo os seguintes parâmetros: porcentagem de tecido ósseo em contato direto com a superfície do implante (CD), porcentagem de preenchimento ósseo das roscas do implante (AO) e porcentagem de tecido mineralizado numa zona de 500 um, adjacente à superfície do implante (PTM). Os parâmetros foram obtidos separadamente para região cortical e região medular. Não foram detectadas diferenças entre os grupos que receberam aplicação de PTH (1-34) (Grupos 3 e 4) em todos os parâmetros avaliados (p>0,05). Além disso, o PTH promoveu um aumento significativo no CD, AO e PTM em ambas as regiões, mesmo na presença de IFC (p<0.05) (exceto para AO na região cortical). Uma influência negativa da IFC foi observada para o parâmetro CD na região cortical, uma vez que o grupo 2 apresentou os menores valores de CD, seguidos do grupo 1. Resultados semelhantes foram observados para PTM em ambas as regiões analisadas. Dentro dos limites deste estudo pode-se concluir que a aplicação intermitente de PTH (1-34) é capaz de minimizar os impactos negativos da inalação da fumaça de cigarro na osseointegração de implantes de titânio inseridos em tíbias de ratas.
Abstract: The aim of this study was to investigate the synthetic parathyroid hormone, PTH (1-34), can mitigate the effect of cigarette smoke inhalation (CSI) on the bone healing around titanium implants inserted in rats. 61 female Wistar rats were randomly assigned to one of four groups: group l(n = 15): animals that received the application of the necessary vehicle for the dissolution of the hormone after installation of the implant; group 2 (n = 16): cigarette smoke inhalation (CSI) for 60 days preoperatively and sixty days after implant placement group 3(n = 17), treatment group 2, associated with subcutaneous injections of 40 u-g / kg of synthetic PTH (1-34) three times a week after implant placement and group 4 (n = 13): subcutaneous injections of 40 ug / kg of synthetic PTH (1-34) three times a week after placement of implants. The animals were sacrificed sixty days after the placement of implants, not decalcified sections were obtained and evaluated histometrically, according to the following parameters: percentage of bone tissue in direct contact with the implant surface (BIC), percentage of bone filling the threads of the implant (BF) and percentage of mineralized tissue in an area of 500 urn adjacent to the implant surface (BA). The parameters were obtained separately for the cortical and cancellous bone. No differences were found between the groups that received PTH (1-34) (Groups 3 and 4) in all evaluations (p> 0.05). In addition, PTH (1-34) caused a significant increase in BIC, BF and BA in both regions, even in the presence of CSI (p <0.05) (except for BF in the cortical region). A negative influence of the IFC was observed for the parameter BIC in the cortical region, as group 2 had the lowest values of BIC, followed by group 1. Similar results were observed for BA in both regions analyzed. Within the limits of this study can conclude that the intermittent application of PTH (1-34) is able to reversing the negative effects of cigarette smoke inhalation on osseointegration of titanium implants inserted in rats.
Doutorado
Periodontia
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
24

Menezes, Alynne Vieira de. "Influencia da inclinação da mandibula em medidas do rebordo alveolar em exames de tomografia computadorizada de feixe conico para implantes." [s.n.], 2010. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290136.

Full text
Abstract:
Orientador: Solange Maria de Almeida
Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-15T20:48:17Z (GMT). No. of bitstreams: 1 Menezes_AlynneVieirade_D.pdf: 1911461 bytes, checksum: 9eed499fb3fe7db23a7c4de2811423d3 (MD5) Previous issue date: 2010
Resumo: A utilização de implantes dentários para a reabilitação de regiões edêntulas é uma das atividades mais crescentes da Odontologia e a utilização de imagens é um fator essencial para se alcançar o almejado sucesso. Vários métodos de imagem vêm sendo utilizados com esse propósito e a tomografia computadorizada de feixe cônico (TCFC) vem se estabelecendo como um dos métodos promissores nesse sentido, pois se trata de um método confiável, capaz de produzir imagens em tamanho real, sem sobreposição e com dose de radiação menor que a tomografia computadorizada fan beam. Neste trabalho teve-se como objetivo avaliar a influência da posição da mandíbula na realização de medidas da altura e da espessura de sítios implantares em cortes ortorradiais de TCFC. Para tanto, foram utilizadas 10 mandíbulas maceradas, sendo obtidas imagens utilizando-se o tomógrafo de feixe cônico i-CAT. Foi realizada uma única imagem de cada mandíbula e a partir dessa imagem, os cortes ortorradiais foram obtidos considerando-se 3 diferentes posições: 1: base da mandíbula paralela ao plano horizontal (Posição Normal - PN); 2: base com inclinação de +10° (Posição Superior - PS) e 3: com inclinação de -10° (Posição Inferior - PI). A altura e a espessura óssea de cada região foram mensuradas por um único examinador e os dados obtidos nos grupos experimentais (PS e PI) foram comparados com os dados obtidos do grupo controle (PN) usando a análise de variância two-way (a=0,05). Os valores médios de altura e de espessura ósseas não variaram significativamente entre as posições inclinadas (PS e PI) e a posição padrão (PN), o que permite concluir que nas inclinações avaliadas, a direção do plano axial não influenciou nas medidas obtidas
Abstract: Dental implants have became part of routine treatment plans in many cases of edentulous patients and an important part of preimplant examination is provided by images of the existing bone structures in addition to the clinical findings. Several imaging modalities have been used for preimplant assessment and the cone-beam computed tomography may indeed be the next major advancement, since provides clinicians with accurate images of high diagnostic quality with relatively short scanning times and a reported radiation dose lower than fan beam computed tomography. The aim of this present study was to investigate the influence of mandibular inclination on the measured height and width of the cortical bone in reformatted cross-sectional cone beam computed tomography. Ten human dry mandibles were scanned with dental CBCT (i-CAT). It was performed only one scan of any mandible and reformatted cross-sectional scans were obtained at three different positions: (1) parallel to the lower border of the mandible (standard position); (2) with a inclination of +10° (Upper Position) and (3) with a n inclination of -10°(Lower Position). The alveolar bone height and width were measured for one examiner and data subjected to two-way analysis of variance and to compare the means obtained for the experimental groups (UP and LP) with the control group (standard position) (a=0,05). Mean values of bone height and width did not varied significantly between the inclined (UP and LP) and the standard positions. It could be concluded that in the positions analyzed, the direction of the axial planes did not influence the measurements obtained
Doutorado
Radiologia Odontologica
Doutor em Radiologia Odontológica
APA, Harvard, Vancouver, ISO, and other styles
25

Aroso, Ribeiro Carlos Manuel. "Retención y desgaste de tres sistemas de "attachment" para prótesis totales mandibulares sobre implantes - Estudio in Vitro." Doctoral thesis, Universitat de Barcelona, 2016. http://hdl.handle.net/10803/401680.

Full text
Abstract:
Mandibular overdentures retained by two implants are recognised as the first option for treating patients without teeth, as stated by the McGill University (Canada) in its consensus statement in 2002 and the British Society to the prosthodontics study, in your consensus statement of York, published in 2009. Compared to conventional full prosthesis, they provide greater satisfaction for the patient, greater chewing ability and preservation of the residual crest height. Purpose: This in vitro study was investigated and compare the durability and retention capacity of 3 types of attachments. Our working hypothesis states that there is no significant retention loss in different systems "attachments" tested and used in implant supported overdentures over the time and no wear in the metal components that`s requiring replacement during the same period. Materials and Methods: Three commercially available attachments were investigated:(Clix®: Preat Corporation, Santa Ynez, CA, United States; Dalbo-Plus®: Cendres+ Métaux, Biel/Bienne, Switzerland; Locator®: Zest Anchors,Inc ,Escondido, United States), 3 different abutments inclinations (0°, 10° and 20°) . The 72 attachments were placed in acrylic resin form and they were then subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH7 and 37°C, and retention values recorded at eight different times (at the beginning, one month, six months, a year, two years, three years, four years and five years). Results: The results revealed that there were significant differences in the average values of insertion/removal force due to the angulation (F (2, 48) =343619, p<0.05) and the type of attachment (F (7, 48) = 23.220, p < 0.05). An analysis of the results showed that the retention average (insertion and removal) for attachments was always more in inclination of 0° than inclination of 20°. Conclusions: All attachments were tested lose the maximum value of retention force. The abutment inclination influences the intrinsic strength value of each attachment and have effect on its durability over the period of time.
Las sobredentaduras mandibulares retenidas por dos implantes son reconocidas como la primera opción de tratamiento para pacientes edéntulos, tal como recoge la Universidad McGill (Canadá) en su declaración de consenso publicada en 2002 y la sociedad británica para el estudio de la odontología protésica, en su declaración de consenso de York, publicada en 2009. Al compararlas con prótesis completas convencionales, proporcionan una mayor satisfacción del paciente, una mayor capacidad masticatoria y una preservación de altura de la cresta residual. El objetivo de este trabajo es evaluar la durabilidad y capacidad de retención de attachments a largo del tiempo en inclinación de 0°, 10° e 20° y en saliva artificial a 37°C.El diseño experimental tomó en cuenta la existencia de 3 tipos distintos de sistemas de attachments (Clix®: Preat Corporation, Santa Ynez, CA, United States; Dalbo-Plus®: Cendres+ Métaux, Biel/Bienne, Suiza; Locator®: Zest Anchors,Inc ,Escondido, United States), 3 inclinaciones diferentes y uno tipo de saliva artificial ( pH 7). Los 72 attachments fueron testados en una máquina de ensayo de fatiga durante 5400 ciclos (cinco años) y se registraron los valores de retención en ocho momentos diferentes (inicio, un mes, seis meses, un año, dos años, tres años, cuatro años, cinco años).El análisis de los resultados demostró que la media de retención (inserción y desinserción) de los attachments fue siempre mayor en inclinación de 0° do que en inclinación de 20°. Todos los attachments del estudio han perdido valor máximo de retención.La inclinación influye en el valor de la fuerza intrínseca de cada attachment y tiene influencia en su durabilidad a lo largo del tiempo.
APA, Harvard, Vancouver, ISO, and other styles
26

Farré, Berga Oriol. "Disseny, anàlisi i avaluació per elements finits i estudis mecànics d'una nova cabota de cargol per a retenció de pròtesis dentals cargolades a implants i la seva respectiva eina." Doctoral thesis, Universitat de Barcelona, 2017. http://hdl.handle.net/10803/405390.

Full text
Abstract:
L'objectiu principal d'aquest estudi va ser dissenyar la geometria òptima d'una nova eina; crear les ranures del cap esfèric d’un nou cargol; i demostrar la seva resistència a un parell de fins a 40 N·cm a una angulació de 0, 15 i 30 graus utilitzant l'anàlisi d'elements finits no lineals. Un objectiu secundari va ser crear un sistema infal·lible i fàcilment recognoscible. Els dissenys del cargol de cap esfèric i la geometria de l’eina, que funcionen a qualsevol angulació de 0 a 30°, es van generar utilitzant el programa Pro-ENGINEER Wildfire 5.0. Les anàlisis estructurals estàtiques entre els cossos en contacte es van realitzar a diferents angles de 0°, 15° i 30° a un parell de 20 N·cm i 40 N·cm, utilitzant la simulació d'elements finits no lineals mitjançant l’ANSYS 12.0. La tensió màxima del cap del cargol i l’eina va ser similar a 20 N·cm i 40 N·cm. Encara que es van trobar deformacions majors a 40 N·cm, aquestes van ser petites i no van afectar el rendiment de l’enllaç. A més, el valor del parell de ruptura de l’enllaç amb rosca M2 va ser de 55 N·cm per a 0° i 30° i 47,5 N·cm per a 15°. L'anàlisi d'elements finits va mostrar que aquest nou cargol de cap esfèric i la seva respectiva eina són una bona solució per utilitzar en pròtesis amb orificis angulats cargolades a implants. Finalment, es van desenvolupar les proves mecàniques necessàries per adquirir dades més fiables i comprendre millor el seu comportament sota condicions de fatiga per tal de determinar la resistència a la torsió del conjunt cargol i eina Ball Head System (BHS) a 0°, 20° i 30° d’angulació; per comparar el conjunt BHS amb el sistema de eina hexagonal de 1,30 mm (HexS) a 20°; i analitzar la condició del conjunt BHS després de 10 i 30 iteracions amb un parell de 30 N·cm a una angulació de 30°. El conjunt BHS permet un parell de fins a 54 N·cm. En les mateixes condicions, el conjunt BHS va mostrar més resistència de parell que el conjunt d’HexS. Aquest últim es va haver de descargolar amb una eina de pressió de taller. Rellevància clínica: Aquest nou conjunt cargol i eina BHS es pot utilitzar per a orificis angulats de fins a 30º, és visualment fàcil d’identificar i fins i tot en presència de deformació del cap del cargol, la majoria es poden descargolar amb la seva pròpia eina.
The primary objective of this study was to design the optimal geometry of a novel screwdriver; create the grooves on a ball head screw; and demonstrate its resistance to a torque of up to 40 N·cm at an angulation of 0, 15 and 30 degrees by using nonlinear finite element analysis (FEA). A secondary objective was to create a foolproof and easily recognizable system. The grooved ball head screw and geometry of the screwdriver, functioning from an angulation of 0° to 30°, was generated using Pro-ENGINEER Wildfire 5.0 software. Static structural analyses between bodies in contact were performed at different angles of 0°, 15° and 30° at a torque of 20 N·cm and 40 N·cm, using nonlinear finite element simulation by means of ANSYS 12.0. The maximum stress supported by the ball head screw and screwdriver was similar at 20 N·cm and 40 N·cm. Although greater deformations were found at 40 N·cm, these were small and might not affect the performance of the system. Besides, the rupture torque value for the M2 connection was 55 N·cm for 0° and 30°, and 47.5 N·cm for 15°. Finite element analysis showed this novel ball head screw and screwdriver system to be a good solution for angled screw channels in implant-supported prostheses. Finally, the needed mechanical tests to acquire more reliable data and to better understand its behaviour under fatigue conditions were developed in order to determine the torsion resistance of the Ball Head System (BHS) screw and screwdriver set at 0°, 20° and 30° angulations; to compare the BHS set with the 1.30 mm hexagonal screwdriver system (HexS) at 20°; and analyse the condition of the BHS after 10 and 30 iterations with 30 N·cm torque at 30° angulation. The BHS allows tightening at a torque of up to 54 N·cm. Under the same conditions, BHS showed more torque resistance than HexS, which could not be removed. Clinical relevance: This new system can be used for angled screw channels, and even in presence of deformation, most can be removed with their own screwdriver.
APA, Harvard, Vancouver, ISO, and other styles
27

Morgan, M. Jane. "Structural analysis of an osseointegrated dental implant system." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1997. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp02/NQ28023.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Aguiar, Juliana Ribeiro Pala Jorge de [UNESP]. "Influência do tipo de conexão pilar/implante na manutenção da pré-carga de parafusos de retenção e na desadaptação vertical da coroa protética antes e após ciclagem mecânica." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/105561.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-05-02Bitstream added on 2014-06-13T19:24:17Z : No. of bitstreams: 1 aguiar_jrpj_dr_araca.pdf: 843042 bytes, checksum: f640ef7de226d005134afbe1456c4ddf (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Próteses implantossuportadas estão sujeitas a diversos tipos de falhas, sendo o afrouxamento do parafuso de retenção a complicação mais frequente, devido à perda da pré-carga inicial. A perda da pré-carga pode ser influenciada por fatores como incidência de cargas oclusais impróprias, diferentes tipos de conexões do sistema implante/prótese e desajustes entre a coroa e o implante. Sendo assim, este estudo teve como objetivo avaliar a manutenção da pré-carga de parafusos de retenção de titânio e a desadaptação vertical de coroas protéticas parafusadas, antes e após a ciclagem mecânica. Para isso, três tipos de conexões implante/pilar foram utilizados: implantes de conexão interna híbrida com pilar do tipo esteticone (grupo CIE); implantes de conexão externa com pilar o tipo esteticone (grupo CEE); e implantes de conexão externa com pilar UCLA (grupo CEU). Para cada grupo, foram confeccionadas 10 coroas metálicas fundidas em liga de CoCrMo para a composição final dos corpos-de-prova. Os parafusos de retenção protéticos receberam torque de 20N.cm nos grupos CIE e CEE e 30N.cm no grupo CEU, e, após três minutos, foi mensurado o valor de destorque inicial, com o auxílio de um torquímetro analógico. Após essa avaliação inicial, as coroas receberam novamente o torque recomendado e foram submetidas ao ensaio de ciclagem mecânica, com carga oblíqua (30°) de 130N ± 10N, a 2Hz de freqüência, totalizando 1x106 ciclos. Após a ciclagem, foi mensurado o destorque final. Além disso, antes e depois da ciclagem mecânica, foi realizada a verificação da adaptação vertical das coroas por meio de um estereomicroscópio, com as coroas parafusadas a um único implante e posicionadas em uma matriz de silicone...
Implant-supported prostheses are prone to several types of fail, and the retaining screw loosening is the most frequent complication, due to the loss of its initial preload. Loss of preload may be caused by different factors such as the incidence of excessive occlusal loading, different types of implant/prosthesis connections systems and vertical misfit between crown and implant. Thus, the aim of this study was to evaluate the preload maintenance of titanium retaining screws and to measure the vertical misfit of implant-supported screwed crowns, before and after mechanical cycling. For this purpose, three types of implant/abutment systems were embedded in polyester resin: internal hybrid connection implants and Estheticone abutments (Group ICE); external connection implants with Estheticone abutments (Group ECE); and external connection implants with UCLA abutments (Group ECU). For each group, 10 metallic crowns were cast in CoCrMo alloy for the final compositions of the specimens. Retaining screws received insertion torque of 20 N.cm in groups ICE and ECE and 30N.cm in group ECU, and, after three minutes, the initial detorque was measured through an analogical torquemeter. After this initial evaluation, crowns were retightened and submitted to cyclic loading test, with an oblique loading (30°) of 130N ± 10N, at 2Hz of frequency, totalizing 1x106 cycles. After cycling, final detorque was measured. Moreover, before and after mechanical cycling, the vertical misfit of the crowns was measured through estereomicroscopy, with the crowns screwed to a single implant and positioned into a silicone matrix. The data obtained were tabulated and submitted to variance analysis, Fisher’s exact test and Pearson’s linear... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
29

Moretti, Lívia Alves Corrêa. "Microtopografia de implantes de titânio com diferentes tratamentos de superfícies à microscopia eletrônica de varredura e de força atômica." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/58/58132/tde-18092012-160925/.

Full text
Abstract:
INTRODUÇÃO: A qualidade da interface osso-implante pode ser influenciada diretamente pela rugosidade da superfície e determina a forma como as células interagem, aderem-se e fixam-se a ela, podendo potencializar e encurtar o tempo de osseointegração. Este estudo propôs-se analisar qualitativamente a topografia e arquitetura de diferentes superfícies de implantes dentários, compará-las, descrevê-las e correlacioná-las com os possíveis eventos moleculares e celulares iniciais da osseointegração. MATERIAIS E MÉTODOS: cinco implantes com diferentes tratamentos de superfície foram analisados em três diferentes áreas: apical, região de roscas (topos, flancos e vales) e região cervical por microscopia eletrônica de varredura (MEV) e topo do ápice em microscopia de força atômica (MFA). RESULTADOS: as superfícies dos implantes NanoTite®, SLA® e Xive® TG plus, no MEV, são semelhantes pelo seu aspecto de lacunas, diferindo no plano superficial; a superfície do implantes TiUnite® apresenta características coraliformes/vulcanoides, enquanto a do implante Exopro® apresenta estrias em formas de pequenos sulcos. A rugosidade média (Ra) à MFA, apresentou-se maior no implante TiUnite®, seguido pelos implantes Xive®TG plus, NanoTite®, Exopro® e SLA®. A área analisada se restringe a pequenos pontos (nanométricos), que não possibilita uma visão panorâmica de todas as estruturas (micrométricas), e consequentemente não permite uma real comparação da rugosidade. CONCLUSÕES: a metodologia ideal para análise das superfícies com o objetivo de compreender como as células às colonizam e se aderem deve ser em escala micrométrica, destacando-se à MEV em detrimento da MFA. As duas metodologias, MEV e MFA, são fundamentais na análise de superfície de implantes dentários, porém devem ser conjuntamente e/ou simultaneamente empregadas. A MFA parece ser a mais adequada para estudos que visem a interação da superfície dos implantes com estrutura de nível molecular e à MEV, no nível celular. Cada tratamento de superfície promove um tipo específico de topografia, cujos benefícios moleculares, teciduais e clínicos devem ser estudados caso a caso.
Introduction: Bone-implant interface quality may be influenced by surface roughness and determines how cells interact, cling to and fix to, therefore can enhance and shorten the time for osseointegration. This study aims to analyze qualitatively the topography and architecture of different dental implants surfaces, to compare and describe them. MATERIALS AND METHODS: five implants with different surface treatments were evaluated in three different areas: apical, region of threads (tops, sides and valleys) and cervical region by scanning electron microscopy (SEM) and atomic force microscopy (AFM), correlating the possible molecular and cellular initials events of osseointegration. RESULTS: the surfaces of the implants NanoTite®, SLA® and ® Xive® TG plus, in the SEM, are similar by their appearance of gaps, although they differ in surface plane; the surface of TiUnite® implants have features such as corals and/or volcanos, while the implant Exopro ® has stretch marks in form of small grooves. The average roughness (Ra) to the AFM, appeared higher in TiUnite ® implant, followed by Xive® TG plus NanoTite®, Exopro® and SLA® implants. The area analyzed in the AFM, is restricted to small points (nanometrics), and do not allow denote a panoramic view of all structures (micrometrics), not allowing a real comparison of surface roughness. CONCLUSIONS: the optimal methodology for surfaces analysis with the objective of understanding how the cells colonize and fix to dental implants should be in the micrometer scale, highlighting the SEM over AFM. The AFM seems to be most suitable for studies aiming the interaction of the implant surface with molecular-level and SEM at the cellular level. Each treatment promotes a specific surface topography whose benefits molecular, tissue, and clinical should be studied separately.
APA, Harvard, Vancouver, ISO, and other styles
30

Pimentel, Gustavo Henrique Diniz [UNESP]. "Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four." Universidade Estadual Paulista (UNESP), 2014. http://hdl.handle.net/11449/145513.

Full text
Abstract:
Made available in DSpace on 2016-12-09T13:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-15. Added 1 bitstream(s) on 2016-12-09T13:55:26Z : No. of bitstreams: 1 000874738.pdf: 3429941 bytes, checksum: f0746f3294aca82e94682f551d6b7ae5 (MD5)
O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar in vitro a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema All-on-four). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo)
Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate in vitro the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating All-on-four system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
31

Pimentel, Gustavo Henrique Diniz. "Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four /." Araraquara, 2014. http://hdl.handle.net/11449/145513.

Full text
Abstract:
Orientador: Francisco de Assis Mollo Junior
Banca: Marco Antônio Compagnoni
Banca: Janaína Habib Jorge
Banca: Estevam Augusto Bonfante
Banca: Ricardo Faria Ribeiro
Resumo: O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar "in vitro" a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema "All-on-four"). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo)
Abstract: Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate "in vitro" the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating "All-on-four" system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below)
Doutor
APA, Harvard, Vancouver, ISO, and other styles
32

Hirayama, Patrícia Mitiko Asanuma. "Efeito do jateamento com óxido de alumínio e uso de adesivo, no afrouxamento do parafuso de pilares protéticos cônicos, com indexador de restaurações implanto suportadas." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/23/23150/tde-04072013-164032/.

Full text
Abstract:
O sucesso dos trabalhos protéticos, executados sobre os implantes osseointegrados, depende da estabilidade da conexão entre implante e pilar protético. Dentre as conexões protéticas existentes, as conexões cônicas têm demonstrado um desempenho melhor, tanto em termos mecânicos, como biológicos. A retenção friccional do pilar cônico é a grande responsável pela resistência aos movimentos laterais e oclusais da mastigação. Com a introdução de indexadores no desenho dessas conexões a característica mecânica mudou, levantando dúvidas em relação a sua atuação. Neste trabalho, avaliou-se o efeito do jateamento e uso do adesivo no torque de desaperto dessas conexões. Vinte e oito pilares synOCta® da marca Straumann® foram avaliados quanto ao torque de aperto inicial de 35 N.cm e torque de desaperto após ciclagem mecânica. Três grupos experimentais foram testados em relação ao grupo controle: modificação da superfície cônica por jateamento com óxido de alumínio, aplicação de adesivo entre as partes e o jateamento mais o adesivo. O grupo jateamento com aplicação do adesivo foi o único que apresentou valores de desaperto superiores quando comparado ao grupo controle. A rugosidade criada pelo jateamento, associada ao adesivo, elevou significantemente os valores de torque de desaperto do parafuso em comparação ao torque de aperto.
The success of the prosthetic work performed over dental implants depends on the stability of the connection between implant and abutment. Among the existing prosthetic connections, the conical connections have shown better performance, both mechanical and biological. The frictional retention of the morse taper is largely responsible for the resistance to lateral and occlusal movements of mastication. With the introduction of indexes in the design of these connections, the mechanical characteristic changed, raising doubts about its performance. In this study, we evaluated the effect of blasting and use of adhesive on abutment screw loosening torque of these connections. Twenty-eight synOcta® pillars Straumann® brand were evaluated for initial tightening torque of 35 N.cm and loosening torque after mechanical cycling. Three experimental groups were tested related to the control group: modification of the conical surface by blasting with aluminum oxide, aplication of adhesive between the parties and blasting added to the adhesive. The group blasted with adhesive application was the only one that showed values of loosening torque higher when compared to control group. The roughness created by blasting associated with the adhesive, significantly elevated values of abutment screw loosening torque against the tightening torque.
APA, Harvard, Vancouver, ISO, and other styles
33

Nemes, Jordan. "Fear of dental implants among edentulous patients." Thesis, McGill University, 2007. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=101732.

Full text
Abstract:
Despite implant-supported overdentures' advantages over conventional dentures, edentulous patients often refuse dental implants for reasons that may be related to fear. Objective. The purpose of this study was to uncover and explain the various forms and sources of dental implant-related fear among edentulous patients. Methods. A convenient sample of 8 edentulous/semi-edentulous participants was used. Participants were recruited from a current study at McGill University's Faculty of Dentistry, posting of recruitment flyers, and local homes and community centers for seniors. One-on-one interviews were conducted in Montreal from March 2005 to February 2006, transcribed verbatim, and coded into multiple theme-based sections. Results. Three categories of implant-related fear were identified: (1) fear of dental implant surgery; (2) fear of the recovery period; and (3) miscellaneous fears. As well, four main sources of dental implant-related fear were uncovered: (1) past negative experiences at the dentist; (2) "horror stories" of dental implant surgery; (3) having relatively little knowledge of dental implants; and (4) poor dentist-patient relationship. Discussion. The various forms of dental implant-related fear seem to play a substantial role in influencing a patient's decision to undergo implant surgery.
APA, Harvard, Vancouver, ISO, and other styles
34

Castro, Gabriela Cassaro de 1986. "Distribuição de tensões ao redor dos implantes em duas condições de desajuste vertical." [s.n.], 2015. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288283.

Full text
Abstract:
Orientador: Mauro Antonio de Arruda Nóbilo
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-26T22:26:53Z (GMT). No. of bitstreams: 1 Castro_GabrielaCassarode_D.pdf: 33391431 bytes, checksum: 639a953ad32049093199c81dd2ea3cb7 (MD5) Previous issue date: 2015
Resumo: Muito se discute sobre importância da passividade, seus efeitos mecânicos e biológicos e a dificuldade em sua obtenção. Devido aos procedimentos inerentes ao processo de confecção da infraestrutura metálica, desde a moldagem à fundição, distorções são incorporadas. Estas tornam-se preocupação biomecânica por gerar tensão no conjunto prótese-implante-osso. Propõe-se avaliar as tensões ao redor dos implantes em infraestruturas de Titânio para prótese total fixa sobre 4 implantes, com diferentes desajustes marginais por meio da fotoelasticidade. Quatro implantes hexágono externo 4,1 x 11,5 mm, foram posicionados sobre uma matriz simulando uma mandíbula edêntula e nomeados da esquerda para direita em A, B, C e D. Aos implantes, foram aparafusados mini-pilares cônicos e entre os pilares e a infraestrutura foram posicionados anéis espaçadores com dimensões conhecidas: para o grupo HE300 (n=5) foi simulado desajuste, respectivamente de A-D: 0 µm, 100 µm, 200 µm e 300 µm, para o grupo HE100 (n=5) apenas desajuste de 100 µm no implante D. A matriz foi duplicada em resina fotoelástica utilizando as infraestruturas como transferente de moldagem. Foram realizadas medições em 6 pontos em cada implante através do teste do parafuso único, em microscópio óptico, para aferir a desadaptação real obtida. Para obter as imagens fotoelásticas padronizadas a infraestrutura foi aparafusada aos pilares e levadas ao polariscópio circular. A tensão cisalhante máxima (Kgf) foi aferida em 7 pontos ao redor de cada implante e comparados quanto as tensões conjuntas em todos os implantes, ao redor de cada implante e na região cervical e apical. Os dados foram tabulados e submetidos à análise estatística pelo teste t de Student, para avaliar a diferença entre as médias de desadaptação e tensão e o teste de correlação de Spearman para verificar a relação entre tensão e desadaptação. A desadaptação média observada foi de 56,96 (±13,23) ?m para o grupo HE100 e de 194,53 (±162,98) ?m para HE300, apresentando diferença entre os grupos. Com relação à tensão, os grupos HE300 e HE100 mostraram-se iguais estatisticamente (p = 0,291). Mas verificou-se correlação positiva entre desadaptação e tensão em HE100 e HE300. Os implantes B, C e D apresentaram maior tensão no grupo HE100 (p < 0,0001) e no grupo HE300, não foi constatado diferença entre os implantes. As tensões foram maiores na cervical do que na região apical em ambos grupos, para HE 100: 36,92 (±9,33) Kgf na região cervical e 17,78 (±4,09) Kgf na região apical; para HE300: 50,37 (±13,20) Kgf na região cervical e para a região apical 21,20 (±3,95) Kgf. O grupo HE300 exibiu significantemente maior valor de tensão na região cervical (p = 0,012). Conclui-se que o desajuste obtido em HE300 foi maior que do grupo HE100 e gerou maior tensão na região cervical. Ao analisar os implantes em conjunto as tensões foram semelhantes estatisticamente. Foi observado correlação entre desajuste e tensão em ambos grupos. Nas duas situações simuladas, a tensão na região cervical foi maior que na apical
Abstract: There is concern over the importance of passivity, its mechanical and biological effects and the difficulty to obtain it. Misalignments are incorporated due to the procedures inherent in the manufacture of the metal frameworks process, from impression to casting. This becomes a biomechanical concern for generating tension in the prosthesis-implant-bone set. It proposes to analyze the stresses around the implants after being bolted with Titanium frameworks for fixed dentures on 4 implants with different marginal misfits through photoelasticity. Four external hex implants, 4.1 x 11.5 mm, were positioned on a matrix simulating an edentulous jaw and named from left to right, A, B, C and D, respectively. Tapered mini-pillars were screwed to the implants and between the pillars and frameworks were positioned spacer rings with known dimensions: For the HE300 (n=5) group there was a simulated misfit, with AD: 0 microns, 100 microns, 200 microns and 300 microns, respectively. For the just misfit HE100 (n=5) group of 100 microns in implant D, the matrix was duplicated in photoelastic resin using the framework as transfer abutment. Measurements were performed in 6 points in each implant, with the single screw test and an optical microscope to measure the real mismatch obtained. For the standardized photoelastic images, infrastructure was bolted to the columns and analyzed at circular polariscope. The maximum shear stress (kgf) was measured at 7 points around each implant and compared as joint stresses in all implants around each implant, cervical and apical region. Data were tabulated and submitted to statistical analysis by Student's t-test, to evaluate the difference between the means of misfit and tension, and the Spearman correlation test to verify the relationship between stress and maladjustment. The average misfit observed was 56.96 (±13.23) microns for the HE100 group, and 194.53 (±162.98) microns for HE300, with differences between groups. Regarding the strain, the HE300 and HE100 groups were statistically equal (p = 0291). Yet there was a positive correlation between misfit and strain into HE100 and HE300. The B, C and D implants presented a higher tension in the HE100 group (p <0.0001) and HE300 group difference was not observed between the implants. Tensions were higher in the cervical than in the apical region in both groups, for HE100: 36.92 (±9.33) and 17.78 (±4.09) kgf in the cervical region, and in the apical region; for HE300: 50.37 (±13.20) kgf in the cervical region, and the apical region 21.20 (±3.95) Kgf. The HE300 group exhibited significantly more tension the cervical region (p = 0.012). It is concluded that the misfit obtained in HE300 was higher than the misfit group HE100 and generated increased tension in the cervical region. However, the analysis of the photoelastic model found tensions to be equal. A direct relationship between misfit and tension was observed in both groups. In both cases simulated, the tension in the cervical region was larger than in the apical
Doutorado
Protese Dental
Doutora em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
35

Mahmoud, Hussein. "A description of dental implants placed at Tygerberg Oral Health Centre." University of the Western Cape, 2019. http://hdl.handle.net/11394/7532.

Full text
Abstract:
Magister Scientiae Dentium - MSc(Dent)
Purpose This study analyzed the dental surgical implant therapy in the past 5 years at Tygerberg Oral Health Centre, UWC Dental School, Cape Town, South Africa. The findings of this study serve as a guideline for the estimation of the prevalence in this dental hospital. The importance of this study was to aid in the establishment of the formalized electronic database for dental implant therapy. The data generated will form a foundational basis for future studies that may be conducted in the field of implantology. Methodology A retrospective cross-sectional study was conducted at the Tygerberg Oral Health Centre. The data was collected from the implant dental records for the years 2012-2017. Variables measured included the patient demographics such as age, gender, an implant placed by type, length, width, and anatomical location. Frequencies and means of data were generated using IBM SPSS v20.
APA, Harvard, Vancouver, ISO, and other styles
36

Mahmoud, Hussein. "A description of dental implants placed at Tygerberg Oral Health Centre." University of Western Cape, 2020. http://hdl.handle.net/11394/7242.

Full text
Abstract:
Magister Scientiae Dentium - MSc(Dent)
This study analyzed the dental surgical implant therapy in the past 5 years at Tygerberg Oral Health Centre, UWC Dental School, Cape Town, South Africa. The findings of this study serve as a guideline for the estimation of the prevalence in this dental hospital. The importance of this study was to aid in the establishment of the formalized electronic database for dental implant therapy. The data generated will form a foundational basis for future studies that may be conducted in the field of implantology.
APA, Harvard, Vancouver, ISO, and other styles
37

Basílio, Mariana de Almeida [UNESP]. "Efetividade de parafusos com tratamento de superfície na estabilidade de pilares em zircônia após carga cíclica." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/97312.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-18Bitstream added on 2014-06-13T19:16:53Z : No. of bitstreams: 1 basilio_ma_me_arafo.pdf: 801760 bytes, checksum: 7941402e0f93534f3eda18455ce01460 (MD5)
Com o objetivo de prevenir o afrouxamento, parafusos do pilar com lubrificantes sólidos de superfície foram desenvolvidos e introduzidos no mercado. Assim, foi proposto avaliar a efetividade de parafusos de liga de titânio com e sem tratamento de superfície sobre a estabilidade de pilares em zircônia (ZrO2) após carga cíclica, bem como observar alterações estruturais por meio de microscopia eletrônica de varredura (MEV). Para isso, 20 pilares UCLA em ZrO2 foram fixados sobre implantes do tipo hexágono externo com torque de 20 Ncm e divididos em 2 grupos (n=10), conforme o parafuso do pilar: (A) pilar-implante e parafuso de liga de titânio (Ti); (B) pilar-implante e parafuso de liga de titânio com cobertura Diamond Like Carbon (DLC/Ti). O valor do torque reverso (pré-carga) foi mensurado antes e após o carregamento. O teste foi realizado de acordo com a norma ISO 14801. Cargas cíclicas (0,5 x 106; 15 Hz) entre 11 - 211 N foram aplicadas com 30º de inclinação em relação ao longo eixo dos implantes. As médias dos grupos foram calculadas e comparadas utilizando análise de variância de dois fatores e testes F (α=0,05). Os resultados mostraram que antes do carregamento a média do grupo Ti foi significativamente maior que a do grupo DLC/Ti (p=0,021). Após o carregamento ambas as médias 14 diminuíram significativamente, sem diferença significante entre elas (p=0,499). As imagens obtidas na MEV revelaram micro-fraturas na base de assentamento do pilar. Nas condições estudadas, concluiu-se que: (1) os parafusos estudados apresentaram efetividade similar com relação à manutenção da pré-carga; (2) a redução significativa no torque reverso e os danos observados na MEV indicam que o acompanhamento dos pacientes é necessário para assegurar a longevidade das restaurações de ZrO2 implanto-suportadas.
In an attempt to prevent screw-loosening problem, abutment screws with surface treatment were developed. Thus, the aim of the current study was to evaluate comparatively the effectiveness of titanium alloy coated screws and noncoated screws on the stability of ZrO2-ceramic abutments after cyclic loading, as soon as observe possible microdamaging in the structure of the components using a scanning electron microscope (SEM). For this, 20 prefabricated ZrO2-ceramic UCLA abutments were tightened to 20 Ncm on their respective external hex implants and divided equally into 2 groups (n=10), according to the type of screws used: (A) implant-abutment and noncoated titanium alloy screw (Ti); (B) implant–abutment and titanium alloy screw with Diamond Like Carbon surface coating (DLC/Ti). The reverse torque value (preload) of the abutment screw was measured before and after loading. The tests were performed according to ISO norm 14801. A cyclic loading (0,5 x 106; 15 Hz) between 11 - 211 N was applied at an angle of 30 degrees to the long axis of the implants. Group means were calculated and compared using ANOVA and F tests (α=0,05). The results showed that before cyclic loading, the mean of Ti group was significantly higher than the DLC/Ti group (p=0,021). After cyclic loading, both means decreased significantly, with no significant differences 16 between them (p=0,499). Under the studied conditions, it can be concluded that: (1) the two abutment screw types presented similar effectiveness in maintaining preload; (2) the significant decrease in reverse torque values and the microdamaging detected at SEM analysis indicate that patient follow-up is needed to ensure the integrity of the ZrO2-ceramic single-implant restorations.
APA, Harvard, Vancouver, ISO, and other styles
38

Almeida, Daniel Augusto de Faria [UNESP]. "Avaliação da influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões: estudo pelo método dos elementos finitos tridimensionais." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/97362.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-10-21Bitstream added on 2014-06-13T19:58:21Z : No. of bitstreams: 1 almeida_daf_me_araca.pdf: 686399 bytes, checksum: 50ad249856d1640af8c25dd2dcb4adb5 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O comportamento biomecânico de um implante dentário osseointegrado desempenha um importante papel na sua longevidade funcional. As limitações anatômicas às vezes tornam necessário o posicionamento de implantes com angulações fora do considerado ideal para as reabilitações protéticas, havendo maior concentração de tensões e reabsorção no osso cortical ao redor do implante. Para solucionar tais situações o profissional deve lançar mão de um cuidadoso planejamento e uso de intermediários angulados, estudando qual conexão protética melhor se adapta a situação clínica. Portanto, o propósito do presente estudo foi analisar a influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados seis modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco ósseo e a presença de um implante (4,0x10 mm) com diferentes angulações (0º, 17º e 30º) e tipos de conexão (Hexágono externo e cone morse), com coroa metalo-cerâmica. Após geração das geometrias, os modelos foram importados para o programa de pré e pós-processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (quatro para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos NeiNastran versão 9.2, executada em uma estação de trabalho...
The biomechanical behavior of an osseointegrated dental implant plays an important role in the longevity. The anatomical limitations sometimes require the placement of implants with angles outside the considered ideal for prosthetic rehabilitation, with higher stress concentration and resorption in cortical bone around the implant. Thus, in some situations, the professional should planning careful the treatment and use the abutment, analyzing the prosthetic connection which best fits the clinical situation. Therefore, the purpose of this study was to analyze the influence of the implant angulation with different types of prosthetic connection on the stress distribution, by three-dimensional finite element method. Six three-dimensional models were made with the aid of the graphical modeling and SolidWorks 2010 Rhinoceros 4.0 and InVesalius.Each model was composed of a bone blockwith an implant (4.0 x 10 mm) with different angulations (0, 17 and 30) and connection types (Hexagon external and Morse taper) with metal-ceramic crown. After generation of the geometries, the models were imported into the pre-and post-processing finite element FEMAP 10.2, where we generated finite element meshes, boundary and loading conditions. The load was applied axial 200N and 100N obliquely to the occlusal surface of crowns. This total load was divided between the cusps (four for the axial load and two oblique lingual to the load). Then, the analysis was generated in and exported 10.2 FEMAP software for calculation in finite element program NeiNastran version 9.2, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and maximum principal stress. The maps for... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
39

Tunes, Fábio Sanches Magalhães. "Análise microbiológica da vedação com selante industrial de microgaps nas diferentes conexões implantares: estudo in vitro." Universidade de São Paulo, 2018. http://www.teses.usp.br/teses/disponiveis/25/25146/tde-02102018-171536/.

Full text
Abstract:
A utilização de implantes osseointegráveis e componentes protéticos tornaram-se recursos muito viáveis à resolução de casos simples e complexos na odontologia reabilitadora. No entanto, a junção implante componente pode apresentar problemas, tais como a presença de um microgap entre essas partes constituintes. Assim, vários materiais tem sido testados na tentativa de obstruir esse espaço, com resultados controversos. O objetivo deste estudo foi avaliar in vitro o comportamento de um adesivo anaeróbico (Loctite® 510, Henkel Ltda) monocomponente, de alta resistência e inerte, na vedação do microgap impedindo a passagem bacteriana do meio externo para o interno do conjunto. Foram utilizados 90 implantes de conexão externa hexagonal (n = 30), conexão interna hexagonal (n = 30) e conexão interna cônica (n = 30), divididos em Grupo Controle (n = 45) e Grupo Teste (n = 45). Os implantes foram abertos em fluxo laminar e cada unidade recebeu 3l de BHI estéril internamente. Sobre cada unidade era parafusado um componente protético especifico para cada marca e com torques recomendados pelos fabricantes com torquímetro digital. Os conjuntos Teste receberam ainda uma fina camada de adesivo que era aplicada com microbrush entre as partes; e todas as unidades dos grupos Controle e Teste foram vedados com material obturador provisório na sua porção mais coronal. Cada conjunto foi então imerso em 75 l de Enterococcus faecalis (ATCC 29212) em minitubos até o limite entre a junção implante/componente protético. Todas as amostras foram incubadas em estufa bacteriológica por 7, 14 e 28 dias a 37oC antes de serem reabertas. Após o período proposto, o conteúdo interno dos implantes foi coletado com cones de papel estéreis, diluído e semeado em placas de Petri, incubadas por 48 horas. Houve diferença significante entre o grupo teste e controle no grupo de conexão externa hexagonal, em todos os tempos (Teste de Fischer e Qui-quadrado, p 0.05). O adesivo anaeróbico testado funciona como barreira, não permitindo a migração de bactérias para o meio interno do conjunto implante/componente protético.
The use of dental implants and prosthetic components have become very feasible resources to solve simple and complex cases in rehabilitation dentistry. However, the implant component junction may present problems, such as the presence of a microgap between these components parts.Therefore, several materials have been tested in an attempt to obstruct this space, with controversial results. The objective of this study was to evaluate in vitro the behavior of an anaerobic monocomponent adhesive (Loctite® 510, Henkel Ltda), high resistance and inert characteristics, in the microgap seal preventing bacterial passage from the external side to the inner side of the assembly. A total of 90 implants were used, with hexagonal external connection (n = 30), internal hexagonal connection (n = 30) and internal conical connection (n = 30) divided into Control Group (n = 45). Implants were opened in laminar flow cabinet and each unit received 3l of sterile BHI internally. On each unit a specific prosthetic component was screwed in for each brand and with torques recommended by the manufacturers with digital torque wrench. The sets of Test also received a thin layer of adhesive that was applied with microbrush between the parts; and all units of the Control and Test groups were sealed with provisional obturator material in their most coronal portion. Each set was immersed in 75 l of Enterococcus faecalis (ATCC - 29212) in mini-tubes to the limit between the implant / prosthetic component junction. All samples were incubated in a bacteriological incubator for 7, 14 and 28 days at 37oC before being reopened. After the proposed period, the internal contents of the implants were collected with sterile paper cones, diluted and seeded in Petri dishes, incubated for 48 hours. There was a significant difference between the test and control groups in the hexagonal external connection group at all times (Fischer and Chi-square test, p 0.05). The anaerobic adhesive tested works as a barrier, not allowing the migration of bacteria into the internal environment of the implant / prosthetic component assembly.
APA, Harvard, Vancouver, ISO, and other styles
40

Antenucci, Rosse Mary Falcón. "Análise das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexões e qualidade óssea : estudo pelo método dos elementos finitos tridimensionais /." Araçatuba : [s.n.], 2011. http://hdl.handle.net/11449/105562.

Full text
Abstract:
Orientador: Eduardo Piza Pellizzer
Coorientador: Pedro Yoshito Noritomi
Banca: Paulo Sérgio Perri de Carvalho
Banca: Fellippo Ramos Verri
Banca: Marcelo Ferraz Mesquita
Banca: Pedro Tortamano Neto
Resumo: Um aspecto crítico que afeta o sucesso ou falha de um implante é a maneira pela qual as tensões são transferidas do implante ao tecido ósseo. A sobrecarga na prótese dentária pode levar a perda da osseointegração, dessa forma, é aconselhável evitar altas concentrações de tensões no osso de suporte, do ponto de vista clínico. Entretanto, o estresse mecânico pode ter consequências positivas ou negativas no tecido ósseo, fatores esses dependentes de vários fatores associados que podem ser mecânicos ou biológicos. Portanto, o propósito do presente estudo foi analisar a influência da qualidade óssea na distribuição das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexão protética, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados doze modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco com diferentes qualidades ósseas (Tipo I, II, III e IV) e a presença de um implante (4,0x10 mm) com diferente tipo de conexão (Hexágono externo, interno e cone Morse), com coroa metalo-cerâmica. Após geração de geometrias, os modelos foram importados para o programa de pré e pós processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (4 para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: A critical issue that affects the success or failure of an implant is the manner in which the stresses are transferred from the implant to bone tissue. The overload can lead the dental implant to loss of osseointegration, thus it is advisable to avoid high stress concentrations in bone support, according to the clinical point of view. However, mechanical stress can bring positive or negative consequences in the bone tissue and these factors depend on association with mechanical or biological factors. Therefore, the purpose of this study was to analyze the influence of bone quality on stress distribution in implant-prosthesis unit with different types of prosthetic connection, by the three-dimensional finite element method. For this, twelve three-dimensional models were made with the aid of SolidWorks 2010 and Rhinoceros 4.0, graphical modeling software, besides the InVesalius. Each model was composed of a block with different bone qualities (Type I, II, III and IV), an implant (4.0 x 10 mm) with different type of prosthetic connection (Hexagon external, internal and Morse taper) and metal ceramic crown. After generation of geometries, the models were imported into FEMAP 10.2, the pre and post-processing finite element software, where it was generated finite element meshes, boundary and loading conditions. The 200N load was applied axially and 100N obliquely on the occlusal surface of crowns. This total load was divided among the cusps (four points for the axial load and two points for the oblique load on the lingual cusps). Then, the analysis was generated in the FEMAP 10.2 and exported to the NeiNastran version 9.2 software for calculation in finite element analysis, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and... (Complete abstract click electronic access below)
Doutor
APA, Harvard, Vancouver, ISO, and other styles
41

Freitas, Júnior Amilcar Chagas. "Plataforma regular versus switching : estudo mecânico por meio de testes laboratoriais de fadiga e análise de elementos finitos em implantes com hexágono externo e interno /." Araçatuba : [s.n.], 2011. http://hdl.handle.net/11449/105554.

Full text
Abstract:
Orientador: Eduardo Passos Rocha
Banca: Wirley Gonçalves Assunção
Banca: Idelmo Rangel Garcia Júnior
Banca: Paulo Guilherme Coelho
Banca: Paulo Francisco César
Resumo: Proposição. O objetivo do presente trabalho foi avaliar a influência do conceito de plataforma switching na confiabilidade e modo de falha de restaurações unitárias sobre implante com hexágono externo ou interno na região anterior da maxila. Adicionalmente, análises de elementos finitos foram realizadas para avaliar o padrão de distribuição de tensão dentro do complexo pilar-implante e no tecido ósseo peri-implantar. Materiais e Métodos. 84 implantes foram divididos em 4 grupos (n = 21) para realização dos testes de fadiga: SWT-EH e REG-EH (implantes de conexão externa com plataforma switching ou regular, respectivamente); SWT-IH e REG-IH (implantes de conexão interna com plataforma switching ou regular, respectivamente). Análises estatísticas de Weibull foram realizadas considerando as missões de 50.000 ciclos a 210N e 300N. Adicionalmente, foram construídos 4 modelos de elementos finitos considerando as mesmas variáveis para obtenção das tensões equivalentes de von Mises (σvM) no complexo pilar-implante e das máximas tensões principais (σmax) no osso peri-implantar. Resultados. Os valores de Beta para os grupos SWT-EH (1,31), REG-EH (1,55), SWT-IH (1,83) e REG-IH (1,82) indicaram que a fadiga acelerou a falha em todos os grupos. Os valores de confiabilidade calculados para os grupos SWT-EH, REG-EH, SWT-IH e REH-IH foram 0,53 (0,33 - 0,70), 0,93 (0,80 - 0,97), 0,99 (0,93 - 0,99) and 0,99 (0,99 -de tensão estiveram no pilar (SWT-IH = 186 MPa e REG-IH = 88.8 MPa). No osso cortical, os implantes com plataforma switching geraram menor tensão (σmax) tanto para conexão externa (SWT-EH = 49.0 MPa e REG-EH = 56.5 MPa) como para conexão interna (SWT-IH = 37.7 MPa e REG-IH = 45.5 MPa)... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: Purpose. The aim of the present study was to evaluate the effect of platform switching concept on reliability and failure modes of anterior single-unit restorations for internal and external hex implants. Additionally, finite element analysis were performed to assess the stress distribution within implant-abutment complex and peri-implant bone. Materials and Methods. 84 implants were divided in 4 groups (n=21) for fatigue tests: REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). Weibull analysis for a mission of 50,000 cycles at 300N was performed. Additionally, 4 three-dimensional finite element models reproducing the characteristics of specimens used in mechanical tests were created to evaluate the equivalent von Mises stress (σvM) within implant-abutment complex and the maximum principal stress (σmax) in the peri-implant bone. Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The calculated reliability for groups SWT-EH, REG-EH, SWT-IH and REH-IH were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), respectively. Failure modes (screw and/or abutment fracture) were similar for regular and switched-platform implants. Within implant-abutment complex, the higher peak of stress (σvM) was observed in fixation screw (SWT-EH = 190 MPa and REG-EH = 160 MPa) for groups with external hex implants; while for groups with internal hex implants was in abutment (SWT-IH = 186 MPa and REG-IH = 88.8 MPa). In the cortical bone... (Complete abstract click electronic access below)
Doutor
APA, Harvard, Vancouver, ISO, and other styles
42

Shibli, Jamil Awad [UNESP]. "Análise microbiológica da peri-implantite induzida por ligadura em diferentes superfícies de implantes osseointegrados: estudo em cães." Universidade Estadual Paulista (UNESP), 2000. http://hdl.handle.net/11449/96212.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-04-17Bitstream added on 2014-06-13T20:17:45Z : No. of bitstreams: 1 shibli_ja_me_arafo.pdf: 739694 bytes, checksum: 57c9b17fc168fc0329fc6f5001a03672 (MD5)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
A microbiota presente na peri-implantite induzida por ligadura, em diferentes superfícies de implantes osseointegrados, foi analisada em 6 cães adultos machos. 36 implantes osseointegrados (9 Ticp: titânio comercialmente puro; 9 TPS: titânio plasma spray; 9 HA: hidroxiapatita; 9 superfícies tratadas com ácidos) foram inseridos e distribuídos igualmente 3 meses após exodontia de todos os pré-molares inferiores. Após um período de 3 meses de osseointegração, os implantes receberam os cicatrizadores. Decorridos 45 dias de cicatrização, amostras peri-implantares foram colhida, utilizando pontas de papel, no período 0 e após a colocação de ligaduras com fio de algodão, nos períodos 20, 40 e 60 dias. A contagem total de microrganismos (CTM) e a proporação de A. actinomycetemcomitans, Bacteroides forsythus, P. gingivalis, P. intermedia, Campylobacter sp, Capnocytophaga sp., Fusobacterium sp., Peptostreptococcus micros, bastonetes anaeróbios Gram-negativos, Streptococcus beta-hemolíticos, Eikenella corrodens e Candida sp. foram analisadas. Não houve diferença da CTM entre as diferentes superfícies (p>0,05). A Pg não foi detectada no tempo 0; nos tempos 20 e 40 foi detectada em 12 implantes (4 Ticp, 4 HA, 2 TPS e 1 Sup. Trat. com ácidos) e no período 60 dias, em 9 (2 Ticp, 3 HA, 2 TPS e 1 Sup. Trat. com ácidos), tendo menor afinidade à superfície tratada com ácidos. Pi foi detectada em 5 implantes (2 Ticp, 2 HA e 1 Sup. Trat. com ácidos) no período 0 e em 100% dos implantes nos demais períodos. Fusobacterium sp. foi detectado em todos os períodos, tendo uma maior afinidade à HA. Streptococcus beta-hemolíticos foi detectado em 6 implantes (3 Ticp, 1 TPS e 2 HA) no período 0 e 30, 26 e 24 implantes respectivamente nos períodos 20, 40 e 60. Campylobacter sp. e Candida sp. foram detectadas em baixas proporções. Os demais microrganismos não... .
The microbiota associated with ligature-induced peri-implantitis, in different dental implants surfaces, was investigated by cultivation on enriched non-selective and various selective solid media, in 6 mongrel dogs. 36 dental implants (9 Ticp: titanium commercially pure; 9 TPS: titanium plasma spray; 9 HA: hidroxiapatite; 9 surfaces acid-etched) were placed in a similar distribution in all dogs 3 months after extraction of all premolars in mandible. Following a healing period of 3 months, healing abutments were installed and 45 days after cotton ligatures were placed and oral-cleaning procedures abolished for 2 months to induce vertical bone loss of about 40%. Microbial samples were with paper points on day of ligature placement and after 20, 40 and 60 days. The total number of cultivable bacteria and proportions of A. actinomycetemcomitans, Bacteroides forsythus, P. gingivalis, P. intermediate, Campylobacter sp., Capnocytophaga sp., Fusobacterium sp., Peptostreptococcus micros, Enteric Gram-negative rods, beta-hemolytic Streptococcus, Eikenella corrodens and Candida sp. were analyzed. No significant microbiological differences were observed among the different surfaces (p>0,05). Pg was not detected in the time 0; already in the times 20 and 40 were detected in 12 dental implants (4 Ticp, 4 HA, 2 TPS and 1 acid-etched surface) and in the period 60 days, in 9(2 Ticp, 3 HA, 2 TPS and 1 acid-etched surface), tends smaller affinity to eh surface with acids-etched surface. Pi was detected in 5 implants (2 Ticp, 2 HA and 1 acid-etched surface) in the period 0 and in 100% of implants in other periods. Fusobacterium sp. was detected in all the periods, tends a larger affinity to HA. Beta-hemolytic Streptococcus was detected in 6 implants (3 Ticp, 1 TPS and 2 HA) in the period 0 and 30, 26 and 24... (Complete abstract, click electronic address below).
APA, Harvard, Vancouver, ISO, and other styles
43

Santiago, Júnior Joel Ferreira. "Avaliação da influência de diferentes materiais oclusais na confecção de próteses fixas implantossuportadas unitárias com diferentes diâmetros dos implantes osseointegrados : estudo pelo método dos elementos finitos tridimensionais /." Araçatuba : [s.n.], 2010. http://hdl.handle.net/11449/93588.

Full text
Abstract:
Resumo: A literatura científica ainda é escassa em relação à influência de diferentes materiais na confecção de próteses fixas implantossuportadas unitárias em relação aos diferentes diâmetros dos implantes osseointegrados na distribuição das tensões; as suas manifestações e repercussões na prática clínica ainda não estão totalmente esclarecidas, sendo a fundamentação científica indispensável. Assim, o objetivo desta dissertação foi avaliar a influência do material de revestimento oclusal na confecção de prótese fixa implantossuportada unitária com diferentes diâmetros de implantes osseointegrados. Para o estudo foram elaborados 08 modelos, representando cada qual uma secção de osso mandibular (osso esponjoso e cortical), com a presença apenas de um implante (Conexão Master Screw, Sistemas de Próteses, São Paulo, Brasil) do tipo hexágono externo de 3.75 mm x 10 mm (4 modelos) e de 5.00 mm x 10 mm (4 modelos) com coroas de porcelana feldspática, ou de resina acrílica, ou de resina composta ou coroa liga de NiCr. Para confecção dos modelos foram utilizados os programas de desenho assistido: Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA) e SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA). Os desenhos tridimensionais foram exportados para o programa de elementos finitos NEI Nastran® 9.0 (Noran Engineering, Inc, EUA), para geração da malha, aplicação da carga e análise. Os resultados foram visualizados através dos mapas de tensão von Mises de cada modelo proposto, a fim de avaliar as variações individuais da distribuição das tensões no implante e na coroa; no osso os resultados foram visualizados através dos mapas de tensão máxima principal. Na carga axial (200 N), o osso cortical não mostrou grandes diferenças entre todos os modelos e o osso trabecular sofreu um aumento das tensões por tração... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The scientific literature is still scarce about the influence of different veneering materials used in fabricating superstructures for implant-retained fixed prostheses in relation to different implant diameters on stress distribution, and the manifestations and implications in clinical practice were not clarified. The aim of this dissertation was to evaluate the influence of occlusal material for single implant-supported fixed prostheses with different implant diameters. For this study were simulated 8 models, representing a section of the mandibular bone (trabecular and cortical bone) with a single external hexagonal implant (Master Screw, Conexão Sistema de Prótese ltda., Sao Paulo, Brazil) of 3.75 x 10 mm (4 models) and 5.00 mm x10 mm (4 models) with a crown with different occlusal materials: feldspathic porcelain crowns, or acrylic resin or composite resin crown or NiCr alloy. The models were designed using computer-aided design softwares : Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp., Massachusetts, USA). The three-dimensional designs were exported to the finite element program NEI Nastran® 9.0 (Noran Engineering, Inc, USA) for mesh generation, load application and analysis. The results were visualized through von Mises stress maps of each model, to assess individual variations of the stress distribution on the implant and crown; bone results were visualized through maps of maximum principal stress. In axial loading (200 N), cortical bone showed no significant differences in all models,on the trabecular bone the tensile stress increased, with regular implant diameter. For non-axial loads (100 N), the cortical bone, the tensile stress increased significantly on the side common the load application, when it reduced the implant diameter; in the trabecular bone showed seemed stress patterns, although more... (Complete abstract click electronic access below)
Orientador: Eduardo Piza Pellizzer
Coorientador: Fellippo Ramos Verri
Banca: Paulo Sérgio Perri de Carvalho
Banca: Alcides Gonini Júnior
Mestre
APA, Harvard, Vancouver, ISO, and other styles
44

Camargo, Luiz Otavio Alves. "\"Análise prospectiva da estabilidade dos tecidos moles ao redor de implantes imediatos com restaurações imediatas em incisivos centrais superiores\"." Universidade de São Paulo, 2007. http://www.teses.usp.br/teses/disponiveis/23/23137/tde-17052007-153752/.

Full text
Abstract:
Os implantes imediatos que recebem restaurações imediatas vêm sendo apresentados na literatura como uma opção de tratamento confiável para a reposição de dentes condenados. No entanto, recentemente, dúvidas com relação à estabilidade dos tecidos periimplantares utilizando esta técnica têm sido levantadas. Neste estudo prospectivo, doze pacientes tiveram seus incisivos centrais superiores condenados substituídos por implantes imediatos e restaurações imediatas. Durante 18 meses, foram acompanhados o comprimento das coroas implanto-suportadas e a distância entre a ponta das papilas e a borda incisal dos dentes vizinhos. Não foi observada diferença estatisticamente significativa entre as medidas obtidas. Os resultados obtidos podem ser atribuídos ao rigoroso critério de seleção dos casos e a técnica cirúrgica aplicada. Pode-se afirmar que os tecidos moles periimplantares de implantes imediatos com restaurações imediatas, mantiveram-se estáveis ao longo dos 18 meses de observação seguindo-se os critérios de seleção e execução desse estudo.
The immediate implants that receive immediate restorations have been presented in literature as a reliable alternative to the replacement of condemned teeth. Recently, however, doubts regarding the perimplantar tissue stability have been raised. In this prospective study, twelve patients had their central maxillary incisor replaced by immediate implant and immediate restoration. After 18 months the papillae height and the Zenith of implant supported crown were compared to the dimensions before dental extraction. No statistically significant difference was observed between the obtained measurements. The authors justify the obtained results to the rigorous selection criteria of the cases that had been part of this sample and the surgical technique applied. In the selections criteria and executions followed in this work to the immediate implant placement and immediate restorations, we can state that the soft perimplantar tissues have been remained stable for the 18 months? observation.
APA, Harvard, Vancouver, ISO, and other styles
45

Ghensi, Paolo. "Biological and microbiological properties of dental implants and their relation to peri-implant diseases." Doctoral thesis, Università degli studi di Trento, 2019. http://hdl.handle.net/11572/242588.

Full text
Abstract:
With the increasing use of dental implants in the population, the past three decades have seen a dramatic growth in the prevalence of two new oral diseases: peri-implantitis which affects both soft and hard tissues surrounding the implant, and mucositis which precedes peri-implantitis and involves instead only soft tissues. Mucositis affects 50% to 90% of implants, while almost 20% of implants develop peri-implantitis that can lead over time to implant loss. The underlying hypothesis of this research project is that dental implant properties and their interaction with surrounding soft and hard tissues and oral microbiome play an important role in the maintenance of peri-implant health. Regarding specific characteristics of dental implants, experimental data are in part still lacking on biochemical behavior of implant surfaces and of possible new coatings able to reduce bacterial colonization. From the microbiological viewpoint, based on the lessons learned from the study of periodontal diseases, there are reasons to believe that specific members of the oral microbial communities represent a prerequisite for the development of peri-implant diseases. A thorough profiling of the microbial organisms associated with disease is thus the first step to undertake in order to develop novel prevention and therapeutic strategies. Currently available studies, however, adopted a study design which is not accounting for inter-subject variability, focused on few cultivable microbes only, or used low-resolution microbial profiling. Overall, there are thus several open questions on implant characteristics and microbiologic aspects that need to be addressed for the next generation of implant care. Because these aspects are tightly interconnected, in this thesis I employed an integrated approach to study multiple aspects of biological and microbiological properties of dental implants and their relation to peri-implant diseases. Starting from implant surfaces, we evaluated the biochemical behavior of a specific type of moderately rough surface. We found that, in-vitro, this surface called OGI (Osteo Growth Induction) positively acts on osteogenic and angiogenic commitment of mesenchymal stem cells (MSC). Still in the field of implant surfaces, we developed and tested in-vitro a potential anti-biofilm sericin-based coating obtaining very promising bacterial inhibition values. Finally, we investigated in-vivo through shotgun metagenomics the plaque microbiome associated with peri-implant health and disease unraveling specific microbial and functional signatures associated with these conditions and identifying specific disease-associated microbiome features. In this work we showed that peri-implant diseases are connected with the specific composition of the plaque microbiome and that implant surfaces, in addition to a potential strong bioactive role, if properly treated can significantly reduce microbial adhesion on them. Stressing that maintenance therapy always remains something essential, new scenarios for the future are possible. Besides the need of employing implants with adequate micro- and macro-characteristics, the ever more in-depth knowledge of the peri-implant microbiome will allow to implement increasingly effective anti-biofilm implant surfaces and to introduce microbiome-based protocols of diagnosis, prevention and personalized therapy.
APA, Harvard, Vancouver, ISO, and other styles
46

Ghensi, Paolo. "Biological and microbiological properties of dental implants and their relation to peri-implant diseases." Doctoral thesis, Università degli studi di Trento, 2019. http://hdl.handle.net/11572/242588.

Full text
Abstract:
With the increasing use of dental implants in the population, the past three decades have seen a dramatic growth in the prevalence of two new oral diseases: peri-implantitis which affects both soft and hard tissues surrounding the implant, and mucositis which precedes peri-implantitis and involves instead only soft tissues. Mucositis affects 50% to 90% of implants, while almost 20% of implants develop peri-implantitis that can lead over time to implant loss. The underlying hypothesis of this research project is that dental implant properties and their interaction with surrounding soft and hard tissues and oral microbiome play an important role in the maintenance of peri-implant health. Regarding specific characteristics of dental implants, experimental data are in part still lacking on biochemical behavior of implant surfaces and of possible new coatings able to reduce bacterial colonization. From the microbiological viewpoint, based on the lessons learned from the study of periodontal diseases, there are reasons to believe that specific members of the oral microbial communities represent a prerequisite for the development of peri-implant diseases. A thorough profiling of the microbial organisms associated with disease is thus the first step to undertake in order to develop novel prevention and therapeutic strategies. Currently available studies, however, adopted a study design which is not accounting for inter-subject variability, focused on few cultivable microbes only, or used low-resolution microbial profiling. Overall, there are thus several open questions on implant characteristics and microbiologic aspects that need to be addressed for the next generation of implant care. Because these aspects are tightly interconnected, in this thesis I employed an integrated approach to study multiple aspects of biological and microbiological properties of dental implants and their relation to peri-implant diseases. Starting from implant surfaces, we evaluated the biochemical behavior of a specific type of moderately rough surface. We found that, in-vitro, this surface called OGI (Osteo Growth Induction) positively acts on osteogenic and angiogenic commitment of mesenchymal stem cells (MSC). Still in the field of implant surfaces, we developed and tested in-vitro a potential anti-biofilm sericin-based coating obtaining very promising bacterial inhibition values. Finally, we investigated in-vivo through shotgun metagenomics the plaque microbiome associated with peri-implant health and disease unraveling specific microbial and functional signatures associated with these conditions and identifying specific disease-associated microbiome features. In this work we showed that peri-implant diseases are connected with the specific composition of the plaque microbiome and that implant surfaces, in addition to a potential strong bioactive role, if properly treated can significantly reduce microbial adhesion on them. Stressing that maintenance therapy always remains something essential, new scenarios for the future are possible. Besides the need of employing implants with adequate micro- and macro-characteristics, the ever more in-depth knowledge of the peri-implant microbiome will allow to implement increasingly effective anti-biofilm implant surfaces and to introduce microbiome-based protocols of diagnosis, prevention and personalized therapy.
APA, Harvard, Vancouver, ISO, and other styles
47

Villa, Luiz Marcelo Ribeiro [UNESP]. "Estudo das tensões em próteses sobre implantes esplintadas: análise pelo método da fotoelasticidade." Universidade Estadual Paulista (UNESP), 2013. http://hdl.handle.net/11449/108703.

Full text
Abstract:
Made available in DSpace on 2014-08-13T14:50:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-09-10Bitstream added on 2014-08-13T18:00:08Z : No. of bitstreams: 1 000764882.pdf: 5546687 bytes, checksum: 876ee1da472cfe331f69881dd5107292 (MD5)
Propósito: O objetivo deste estudo foi avaliar a influência da esplintagem e de diferentes comprimentos de implantes na distribuição de tensões em próteses implantossuportadas, sob carregamento axial e oblíquo, por meio do método da fotoelasticidade. Materiais e métodos: Um total de 05 modelos em resina fotoelástica foi confeccionado com diferentes situações propostas, realizaram-se 400 aplicações de carga para análise. As tensões foram consideradas de forma quantitativa e qualitativa utilizando um método randomizado e simples cego. A reprodutibilidade do estudo foi avaliada usando o coeficiente de correlação intra-examinador (CCI), erro sistemático e erro casual. A análise de variância a três critérios e pós-teste de Tukey foram utilizados e, valor de p>0.05 foi adotado para analisar as principais diferenças. Resultados: As mensurações mostraram elevado coeficiente de concordância intraexaminador (CCI>0.97). A esplintagem de próteses implantossuportadas agiu favoravelmente na distribuição de tensões e na transmissão de tensões para o implante adjacente (p<0.001), quando comparado a próteses unitárias. O carregamento oblíquo foi mais prejudicial e, pontecializou a formação de tensões em implantes adjacentes (p<0.001). O aumento do comprimento foi um fator significante na avaliação dos modelos B e C (p=0.004), o modelo B apresentou maior concentração de franjas quando comparado com D e E (p<0.001). Conclusão: As próteses implantossuportadas esplintadas comportaram-se melhor biomecanicamente quando comparadas as próteses unitárias. O aumento do comprimento teve relevância na redução de tensões. O carregamento oblíquo foi mais prejudicial para a distribuição de tensões quando comparado com o carregamento axial.
Purpose: The purpose of this study was to evaluate the influence of different lengths and splinting of implants on stress distribution in implant-supported prostheses under axial and oblique loading by means of the method of photoelasticity. Materials and methods: 05 models in photoelastic resin was prepared with different proposed situations, there were 400 applications for load analysis. Tensions were considered quantitatively and qualitatively using a randomized, single blind method. The reproducibility of the study was assessed using the intra correlation coefficient, systematic error and random error. The analysis of variance to three criteria and post - Tukey tests were used, and p values > 0.05 was adopted to analyze the main differences. Results: The measurements showed a high intra-concordance coefficient (ICC> 0.97). The prosthetic implant splinting acted favorably in the distribution of stresses and strains in the transmission next to the implant (p<0.001) when compared to the unitary prosthesis. The oblique loading was more damaging and potentialized the formation of stresses in adjacent implants (p<0.001). The increase in length was a significant factor for the evaluation of the models B and C (p = 0.004), the model B had a higher concentration of fringes as compared with D and E (p<0.001). Conclusion: The prosthetic implant splinted behaved better biomechanically compared prosthetics unit. The increased length was important in reducing stress. The oblique loading was more detrimental to the stress distribution compared to axial loading.
APA, Harvard, Vancouver, ISO, and other styles
48

Villa, Luiz Marcelo Ribeiro. "Estudo das tensões em próteses sobre implantes esplintadas : análise pelo método da fotoelasticidade /." Araçatuba, 2013. http://hdl.handle.net/11449/108703.

Full text
Abstract:
Orientador: Eduardo Piza Pellizzer
Banca: Marcelo Coelho Goiato
Banca: Stefan Fiuza de Carvalho Dekon
Banca: Regina Tamaki
Banca: Sandra Lúcia Dantas de Moraes
Resumo: Propósito: O objetivo deste estudo foi avaliar a influência da esplintagem e de diferentes comprimentos de implantes na distribuição de tensões em próteses implantossuportadas, sob carregamento axial e oblíquo, por meio do método da fotoelasticidade. Materiais e métodos: Um total de 05 modelos em resina fotoelástica foi confeccionado com diferentes situações propostas, realizaram-se 400 aplicações de carga para análise. As tensões foram consideradas de forma quantitativa e qualitativa utilizando um método randomizado e simples cego. A reprodutibilidade do estudo foi avaliada usando o coeficiente de correlação intra-examinador (CCI), erro sistemático e erro casual. A análise de variância a três critérios e pós-teste de Tukey foram utilizados e, valor de p>0.05 foi adotado para analisar as principais diferenças. Resultados: As mensurações mostraram elevado coeficiente de concordância intraexaminador (CCI>0.97). A esplintagem de próteses implantossuportadas agiu favoravelmente na distribuição de tensões e na transmissão de tensões para o implante adjacente (p<0.001), quando comparado a próteses unitárias. O carregamento oblíquo foi mais prejudicial e, pontecializou a formação de tensões em implantes adjacentes (p<0.001). O aumento do comprimento foi um fator significante na avaliação dos modelos B e C (p=0.004), o modelo B apresentou maior concentração de franjas quando comparado com D e E (p<0.001). Conclusão: As próteses implantossuportadas esplintadas comportaram-se melhor biomecanicamente quando comparadas as próteses unitárias. O aumento do comprimento teve relevância na redução de tensões. O carregamento oblíquo foi mais prejudicial para a distribuição de tensões quando comparado com o carregamento axial.
Abstract: Purpose: The purpose of this study was to evaluate the influence of different lengths and splinting of implants on stress distribution in implant-supported prostheses under axial and oblique loading by means of the method of photoelasticity. Materials and methods: 05 models in photoelastic resin was prepared with different proposed situations, there were 400 applications for load analysis. Tensions were considered quantitatively and qualitatively using a randomized, single blind method. The reproducibility of the study was assessed using the intra correlation coefficient, systematic error and random error. The analysis of variance to three criteria and post - Tukey tests were used, and p values > 0.05 was adopted to analyze the main differences. Results: The measurements showed a high intra-concordance coefficient (ICC> 0.97). The prosthetic implant splinting acted favorably in the distribution of stresses and strains in the transmission next to the implant (p<0.001) when compared to the unitary prosthesis. The oblique loading was more damaging and potentialized the formation of stresses in adjacent implants (p<0.001). The increase in length was a significant factor for the evaluation of the models B and C (p = 0.004), the model B had a higher concentration of fringes as compared with D and E (p<0.001). Conclusion: The prosthetic implant splinted behaved better biomechanically compared prosthetics unit. The increased length was important in reducing stress. The oblique loading was more detrimental to the stress distribution compared to axial loading.
Doutor
APA, Harvard, Vancouver, ISO, and other styles
49

Machado, Ana Carolina Masarolo. "Analise fotoelastica da distribuição de tensão em diferentes sistemas de overdentures sobre implantes osseointegrados." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288261.

Full text
Abstract:
Orientador: Mauro Antonio de Arruda Nobilo
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-13T03:34:41Z (GMT). No. of bitstreams: 1 Machado_AnaCarolinaMasarolo_M.pdf: 6585345 bytes, checksum: 5509254e08a517d153fa1da25652f8e0 (MD5) Previous issue date: 2009
Resumo: A proposta deste estudo in vitro, foi avaliar comparativamente por meio da fotoelasticidade, os padrões de tensões geradas ao redor dos implantes e rebordo residual variando-se os sistemas de retenção em overdentures. O estudo foi baseado em três sistemas de retenção para prótese tipo overdenture, a saber: sistema o'ring com 2 implantes (GI), barra-clipe com 2 implantes (GII) e barra-clipe e o'rings distais com 4 implantes (GIII). Sobre protótipos de mandíbulas humanas desdentadas, confeccionados por meio do processo de prototipagem pelo CTI (Centro de Tecnologia da Informação, Campinas, SP) foram fixados 2 ou 4 análogos de pilares Micro-Unit (GI e GII) e análogos de implantes (GI) (Master, Conexão - São Paulo - SP) dispostos nas regiões de caninos e primeiros pré-molares inferiores. Em seguida, foram obtidos moldes dos protótipos mandibulares utilizando silicone para duplicação (Silicone Master - Talladium do Brasil), e técnica de moldagem de transferência com transferentes quadrados unidos com resina acrílica (GC Pattern - GC Dental). A partir destes moldes foram obtidas três matrizes em resina fotoelástica Araldite (Araltec Produtos Químicos Ltda., Hunstman, Guarulhos, São Paulo) com 2 ou 4 implantes osseointegrados (Master - Conexão) incorporados e/ou pilares Micro-Unit. Foram confeccionados modelos de trabalho, nos quais foram realizados os procedimentos de soldagem a laser das barras metálicas, através da moldagem de transferência do posicionamento dos implantes no protótipo mandibular. Após a adaptação de cada sistema de overdentures sobre o modelo fotoelástico, foram aplicadas cargas oclusais de 100N alternadas nas regiões posteriores e anteriores. A análise fotoelástica foi realizada com o auxílio de polariscópio plano acoplado a câmera digital Sony Cybershot a100 (Sony Corp, Japão) que permitiu visualizar as franjas e registrar as imagens em fotografias digitais. Os resultados demonstraram maior concentração de tensão no GIII, apresentando menor distribuição ao rebordo residual e sobrecarga dos implantes posteriores. O GI mostrou o menor nível de tensão, o GII intermediário nível de tensão e houve distribuição da tensão ao rebordo posterior nestes dois grupos. Palavras-chave: Implante Osseointegrado, Overdentue, Sistema Barra-clipe, Sistema O'ring, Análise Fotoelástica
Abstract: The aim of this study was to evaluate through photoelastic analysis, the distribution of generated stress around implants and adjacent bone tissue, using differents implant-retained overdentures designs. Over an edentulous human mandible, achieve from a human model, 2 or 4 micro-unit replications abutments were embedded (Master, Conexao - Sao Paulo - SP) settled in the interforaminal region. Three models of photoelastic resin (Araltec Chemicals Ltda. Hunstman, Guarulhos, Sao Paulo, Brazil), with 2 or 4 incorporated implants (Master - Conexao) and Micro-Unit abutments, were obtained from mulds using silicone for duplication (Silicone Master - talladium do Brazil). Inclusion, finishing and polishing procedures were applied on the frameworks. This study was based on three different mechanisms of implant-retained mandibular overdentures: ball attachment (GI), bar attachment (GII) (both with 2 implants) and their association (GIII) (with 4 implants). After the adaptation of each overdenture system on the photoelastics models, 100N alternates oclusals charges were applied on backside and frontside regions. The photoelastic analysis was made with the aid of a plain polariscope (Measurements Group, USA) linked to a digital camera Sony Cybershot a100 (Sony Corp, Japan) that allowed visualize the fringes and register images on digital photos. The results demonstrated higher tension concentrated over the Group III, with a flat distribution of stress to the posterior ridge and overload on the posterior implants. Group I showed the smaller stress level and Group II intermediate level, there was distribution of stress to the posterior ridge in this two groups. Key words: Osseointegrated Implant, Overdenture, Bar System, Ball System, Photoelastic Analysis
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
50

Braga, Francisco Pantoja. "Avaliação in vitro da precisão de técnicas de moldagens para implantes osseointegrados." [s.n.], 2010. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289178.

Full text
Abstract:
Orientador: Guilherme Elias Pessanha Henriques
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-16T00:42:59Z (GMT). No. of bitstreams: 1 Braga_FranciscoPantoja_M.pdf: 1746788 bytes, checksum: 2e92ba56c05af0022643d89add3ac42c (MD5) Previous issue date: 2010
Resumo: Este estudo In vitro teve como objetivo avaliar a precisão de quatro técnicas de moldagens para implantes ósseo integrados. A partir de uma matriz metálica contendo três implantes foi construída uma supraestrutura simulando uma prótese. As quatro técnicas estudadas foram assim separadas: Grupo A - 10 moldagens com transferentes cônicos (sem união) em moldeiras individuais fechadas; Grupo B - 10 moldagens com transferentes quadrados isolados em moldeiras abertas; Grupo C - 10 moldagens com transferentes quadrados unidos com resina autopolimerizável em moldeiras individuais abertas; Grupo D - 10 moldagens com transferentes quadrados unidos com resina composta Bis-acrílica autopolimerizável em moldeiras individuais abertas. O material de moldagem para todos os grupos foi o silicone de adição Honigum Mono (DMG) e o gesso utilizado para a fabricação dos modelos foi Resin Rock (Whip Mix-USA). Desajustes marginais foram avaliados entre a supra estrutura metálica parafusada aos modelos de trabalho obtidos a partir das moldagens utilizando-se microscópio óptico (aumento de 120X), assim como as tensões induzidas à supraestrutura, avaliadas por extensometria. Para a comparação dos grupos foi utilizado o teste não-paramétrico de Kruskal-Wallis com nível de significância de 5%, para a verificação de existência de diferença significativa entre os grupos com respeito às duas variáveis estudadas. Utilizou-se comparações múltiplas não-paramétricas, para indicar qual ou quais os grupos que levaram à significância estatística. O teste de Kruskal-Wallis para a variável tensão apresentou valor de p= 0,0043 e para a variável desajuste o p encontrado foi igual a 0,6073. Sendo 5% o nível fixado, foi possível observar que apenas para a variável tensão os grupos apresentaram diferença significativa entre si. Foi calculado o coeficiente de correlação de Pearson para as variáveis tensão e desajuste, indicando correlação positiva entre as variáveis. Esta correlação foi altamente significativa (p=0,0074). Os demais valores encontrados não apresentaram significância estatística. Concluiu-se que a mais precisa dentre as quatro técnicas estudadas foi a que usou transferentes quadrados esplintados com bastões de resina pré- fabricados e que houve correlação direta entre desajuste marginal e tensões geradas à supraestrutura
Abstract: The main objective of this study in vitro is to evaluate the accuracy of four techniques of moldings implants osseointegrated. Starting from a metallic matrix with three implants, simulating a clinical situation, was constructed one super structure simulating one prosthesis. The four studied techniques were separated like this: Group A - 10 impressions with conic transfer in closed custom tray; Group B- 10 impressions with square transfer isolated in open custom tray; Group C- 10 impressions with square transfer splinted with autopolymerizing acrylic resin; Group D- 10 impressions taken with square transfer splinted with composite resin Bis-acrilic autopolymerizing in open custom tray. The impression taken material for all groups was vinyl polysiloxane Honigum (DMG), and the gypsum used was Resin Rock (Whip Mix-USA). Strains were analyzed by the use of strain gauges and misfit was analyzed by an optical microscope. The non-parametric test of Kruskal-Wallis was used to compare the 4 groups with a 5% level of significance to verify the significant difference among the groups with respect of the two studied variables. Multiple comparisons were used and they were non-parametric to indicate which group or groups will carry significance to statistics. The Kruskal-Wallis test as far as tension is concerned presented the value of p= 0.0043 and as far as misfit is concerned the p found was 0.6073. Being 5% the level established it is possible to observe that only the variable of tension in the groups show a significant difference among themselves. The correlated coefficient of Pearson was calculated between tension and misfit to each set of data in all the groups evaluated in the research, indicating positive correlation between tension and misfit. This correlation is highly significant (p-value 0.0074). The other values were not statistically significant. Conclusion: The most precise technique of the four was the one that used squared splinted transfers with prefabricated stick autopolymerizing acrylic resin and it had direct correlation between among misfit and tensions generated in the super structure
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography