Dissertations / Theses on the topic 'Denses materials'

To see the other types of publications on this topic, follow the link: Denses materials.

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Denses materials.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Maillard, Mathilde. "Imprimabilité de pâtes céramiques par robocasting : Applications aux matériaux denses et multimatériaux." Thesis, Lyon, 2022. https://theses.insa-lyon.fr/publication/2022LYSEI035/these.pdf.

Full text
Abstract:
Ce travail de thèse a pour objectif d'élaborer des pièces céramiques denses mono et multi-matériaux ayant des architectures complexes. Ces architectures sont réalisées à l'aide d'une technologie de fabrication additive d'extrusion de pâtes céramiques à travers une fine seringue (DIW : robocasting). Ce travail de recherche est financé par le projet ANR CERAPIDE qui a pour objectif la réalisation de pièces céramiques plus rapidement et en consommant moins d'énergie, de sa formulation jusqu'aux étapes de post traitements thermiques. Ainsi, les formulations des pâtes sont optimisées en adaptant les additifs et leurs quantités dans le but d'obtenir des pâtes homogènes, sans défauts et ayant les propriétés rhéologiques nécessaires pour l'impression. Une pâte céramique doit entre autres disposer d'un comportement rhéofluidifiant tout en disposant d'une contrainte seuil élevée pour pouvoir être imprimée par empilement successif de couches. La maitrise rhéologique et l'optimisation des formulations permettent d'imprimer des pièces denses avec des propriétés mécaniques améliorées. Le changement d'additif permet de modifier l'état de surface des pièces denses et donc de modifier les propriétés mécaniques des pièces. La définition de l'imprimabilité des pâtes céramiques est étudiée pour comprendre les relations entre les propriétés microstructurales, environnementales et technologiques. Ainsi, les paramètres d'impressions doivent être sélectionnés en fonction des propriétés finales souhaitées pour la pièce imprimée. La compréhension de tous ces paramètres permet d'élaborer des pièces en alumine ayant une moyenne de contrainte à la rupture de 350 MPa sans étapes de polissage
The main goal of this thesis is to elaborate dense single and multi-material ceramic parts with complex architectures. These architectures are realized using an additive manufacturing technology of extrusion of ceramic pastes through a fine syringe (DIW : robocasting). This research work is financed by the ANR CERAPIDE project, which aims to produce ceramic parts more quickly and with less energy consumption, from formulation to post heat treatment stages. Thus, the formulations of the pastes are optimized by adapting the additives and their quantities in order to obtain homogeneous pastes, without defects and having the rheological properties necessary for printing. Among other things, a ceramic paste must have be shear-thinning while having a high yield stress to be able to be printed by successive stacking of layers. The rheological control and the optimization of the formulations allow to print dense parts with improved mechanical properties. The change of additive allows to modify the topography of the dense parts and thus to modify the mechanical properties of the parts. The definition of printability of ceramic pastes is studied to understand the relationships between microstructural, environmental and technological properties. Finally, the printing parameters must be selected according to the final properties desired for the printed part. The understanding of all these parameters allows the development of alumina parts with an average stress at break of 350 MPa without polishing steps
APA, Harvard, Vancouver, ISO, and other styles
2

Simon, Jean-Christophe. "Diffusion électromagnétique dépendante dans les milieux hétérogènes denses." Rouen, 1994. http://www.theses.fr/1994ROUES061.

Full text
Abstract:
Il est montré que la diffusion électromagnétique dans les milieux hétérogènes denses fait intervenir de nombreux couplages multipolaires entre les particules. Dans ce travail, la distinction est faite entre la diffusion indépendante, couramment utilisée, et la diffusion dépendante. La première partie décrit les effets de diffusions multiple et cohérente, phénomènes liés à la diffusion indépendante. L'équation de transfert radiatif est résolue par une méthode de Monte-Carlo, et l'influence des propriétés d'absorption du milieu environnant les particules est mise en évidence. Les limites de la diffusion indépendante sont exposées à l'aide d'une expérience d'extinction par des particules de verre placées dans une cuve. La seconde partie traite de la diffusion dépendante, et décrit sa théorie. Le théorème d'addition des fonctions d'onde vectorielles harmoniques sphériques est étudié numériquement, en montrant de nombreux exemples caractéristiques. Un critère de convergence des sommations infinies intervenant dans ce théorème est testé, et nous statuons sur ses limites. Enfin, l'application de cette théorie aux milieux réels fortement concentrés est discutée, et son adaptation à l'équation de transfert radiatif est étudiée
APA, Harvard, Vancouver, ISO, and other styles
3

Khamseh, Saeed. "Rheophysics of granular materials with interstitial fluid : a numerical simulation study." Thesis, Paris Est, 2014. http://www.theses.fr/2014PEST1025/document.

Full text
Abstract:
Nous étudions la rhéologie d'un ensemble de grains sphériques et frottants, par la simulation numérique, à l'échelle des grains, d'écoulements de cisaillement sous une contrainte normale P contrôlée, en présence d'un liquide interstitiel. En faible teneur, ce liquide se présente sous forme de ménisques intergranulaires qui transmettent des forces capillaires attractives ; s'il sature l'espace intergranulaire, on s'intéresse alors à l'écoulement de Stokes de la suspension dense ainsi constituée, où dominent les forces visqueuses. Les assemblages de grains secs constituent un système de référence aux propriétés mécaniques bien connues, en particulier l'approche de l'état critique de la mécanique des sols dans la limite quasi-statique. L'effet des ménisques capillaires qui joignent les grains en présence d'un liquide en faible saturation (régime pendulaire) est étudié pour les taux de cisaillement allant du régime quasi statique au régime inertiel. La rhéologie est caractérisée par le frottement interne apparent, la compacité de l'assemblage, les différences de contraintes normales et diverses variables internes, fonctions de deux paramètres de contrôle adimensionnés : le nombre inertiel I et la pression réduite P*, qui compare les forces de confinement à l'adhésion dans les contacts. Notre étude concerne les états homogènes, ce qui exclut les états de cisaillement localisés observés à faible P*, de l'ordre de 0,1. Le coefficient de frottement interne augmente de 0.35 (cas sec) à 0.9 environ pour P*=0.4, tandis que la compacité décroît de 0.59 à 0.52. L'important effet des forces capillaires sur la rhéologie, sensible pour des P* de plusieurs unités, est relié à la texture anisotrope des contacts et des ponts liquides. Lorsque P* décroît, nombre de contacts cohésifs sont maintenus pour des intervalles de déformation de plusieurs unités, survivant aux effets de rotation et de cisaillement de l'écoulement, et forment des amas percolants dans le système entier. Les résultats sont modérément sensibles à la saturation dans le régime pendulaire, mais fortement affectés par l'hystérèse de la conformation des ménisques. En présence de forces visqueuses et non plus capillaires, une version simplifiée de la dynamique stokésienne est adoptée dans laquelle les forces de lubrification entre proches voisins, supposées dominantes, sont les seules interactions hydrodynamiques. La rhéologie est fortement influencée par les contacts intergranulaires directes, qu'autorise la coupure à courte distance de la singulérité de lubrification du fait de la rugosité de surface des particules. Le même état critique que celui des grains secs est approché dans la limite quasi-statique. Nous discutons de lois rhéologiques exprimées en fonction du nombre visqueux qui remplace alors le nombre inertiel, et de la divergence de la viscosité effective à l'approche de la compacité critique en écoulement permanent, ou de la compacité maximale des assemblages aléatoires pour les configurations isotropes désordonnées
We numerically simulate the shear flow of dense assemblies of 3D frictional spherical grains under a fixed normal stress P in steady-state, either in the presence of a small amount of an interstitial liquid, which gives rise to capillary menisci and attractive forces, or in the fully saturated state, when the mechanical properties of suspensions in Stokes flow are controlled by hydrodynamic and contact forces. Dry grain assemblies are used as a reference system for which the rheological properties - in particular the approach to the critical state – are rather well known and can be measured with good accuracy. A non-saturating wetting fluid creates capillary attractive intergranular forces, the effects of which on the rheology are investigated in the pendular state, with shear rates ranging from quasistatic to inertial regimes. The system behavior is characterized by the dependence of internal friction coefficient, solid fraction, normal stress differences and internal state parameters on two dimensionless control parameters: the inertial number, I and the reduced pressure, P*, comparing confining forces to contact tensile strength. We focus on steady homogeneous flows, excluding localized flow patterns which we observe to occur for low P* (of order 0.1). The apparent internal friction coefficient increases to 0.9 in the quasistatic limit for P*=0.4, from its dry value 0.35, while solid fraction decreases from 0.59 to 0.52. We relate the significant effect of capillary forces on the macroscopic behavior of the system, up to P* values of several unities, to fabric anisotropy parameters of contact and distant interactions. As P* decreases, many cohesive contacts are observed to survive the tumbling motion associated to the shear flow, and their average age exceeds the reciprocal shear rate. Corresponding clusters of grains with enduring capillary bonds gather a large proportion of grains and percolate through the sample. The results are shown to be moderately sensitive to saturation within the pendular range, yet rather strongly affected by the hysteretic nature of liquid bridges. In the presence of viscous forces, assuming lubrication effects to dominate the hydrodynamic interactions, we adopt a simplified version of the (overdamped) Stokesian dynamics approach, in which hydrodynamic interactions only couple close neighbours. Rheological properties are strongly influenced by direct intergranular contacts and friction, which are permitted due to a very small distance lubrication cutoff modeling surface asperities. The same critical state as in the dry case is approached in the quasistatic limit. We discuss expressions of rheological laws involving the viscous number instead of the inertial number, and the divergence of effective viscosities in steady flow and in isotropic random suspensions as either the critical state or the random close packing solid fraction are approached
APA, Harvard, Vancouver, ISO, and other styles
4

Odinot, Julie. "Développement de la fabrication additive directe par DED-CLAD : de la poudre à la mise en forme de pièces céramiques denses." Thesis, Université Paris-Saclay (ComUE), 2019. http://www.theses.fr/2019SACLN059.

Full text
Abstract:
Les techniques d’élaboration de matériaux par fabrication additive (FA) sont en plein essor [1]. Elles permettent de fabriquer des pièces par ajout de matière, en opposition avec les techniques traditionnelles par soustraction de matière (usinage). Il existe à l’heure actuelle de nombreux procédés de FA, adaptés à différentes applications : fusion ou frittage par faisceau d’électrons ou par laser, dépôt de matière direct ou en lit de poudre… Ces procédés ont été bien développés pour des matériaux polymères puis métalliques. Des techniques de FA de matériaux céramiques via des polymères chargés ont également vu le jour, mais celles-ci nécessitent des traitements postérieurs (cycles de déliantage, frittage) [2]. Les matériaux céramiques denses sont encore peu développés en fabrication additive en raison de la fissuration de ces matériaux lors de leur élaboration.La technologie CLAD (Construction Laser Additive Directe), développée par IREPA-LASER, permet la fabrication de pièces par dépôt de matière fondue. Le matériau sous forme de poudre est acheminé via une buse laser et projeté dans le faisceau. Il est ainsi porté à la température de fusion. La fusion successive de plusieurs couches permet l’obtention de la pièce. Cette technique, en plus de n’utiliser que la matière nécessaire (contrairement aux techniques de fabrication par lit de poudre), permet la fabrication de pièces de grandes dimensions, voire en multi-matériaux. Cette technologie est, pour l’heure, dédiée aux matériaux métalliques.L’objet de ce sujet de thèse, en partenariat entre l’ONERA et IREPA-LASER dans le cadre du projet inter-Carnot CLADIATOR, est d’étudier la FA de matériaux céramiques denses par le procédé CLAD®. Cette étude porte ainsi sur le procédé dans son ensemble, des matières premières aux pièces finales, en passant par l’adaptation du moyen de fabrication aux contraintes spécifiques liées aux matériaux céramiques.Les matières premières exigent d’être adaptées au procédé ; les deux principales difficultés étant la coulabilité de la poudre, nécessaire pour son acheminement dans la buse, et l’absorption de la source laser par le matériau pour sa montée en température. En parallèle de la caractérisation des matières premières (granulométrie, MEB, dilatométrie, DRX…), des essais d’atomisation par séchage seront effectués pour optimiser la coulabilité des poudres [3]. Ce procédé d’atomisation permet d’obtenir des poudres sous forme d’agglomérats sphériques de plus petites particules ; leur forme est régulière, mais elles restent poreuses. L’ajout de dopants sera étudié pour améliorer l’absorption du signal, en adéquation avec une éventuelle adaptation du laser. Les matériaux considérés sont l’alumine, la zircone ainsi que des compositions eutectiques d’alumine-zircone.La principale difficulté de ce sujet réside dans la sensibilité à la fissuration des matériaux céramiques, en raison du fort gradient thermique induit par le chauffage local du laser et le refroidissement de la pièce. Des solutions de chauffage de la pièce et/ou du matériau avant et après le dépôt seront étudiées pour limiter les contraintes thermomécaniques subies par le matériau [3,4].La machine devra également être modifiée pour supporter les températures élevées nécessaires à l’élaboration de céramiques (températures de fusion et dispositif de pré/post chauffage). L’étude et l’optimisation de ces solutions seront effectuées à l’aide de modélisations multi physiques sur le logiciel COMSOL en collaboration avec IREPA-LASER.Enfin, l’influence du procédé d’élaboration sur l’état des pièces réalisées sera étudiée grâce à des caractérisations microscopiques, mécaniques, thermiques…
This work, in partnership between the ONERA Materials and Composite Structure Department (DMSC) and IREPA Laser within the CLADIATOR project, is based on the study of direct additive manufacturing of dense ceramic materials by direct melt deposition (also known as laser cladding) process. This process enables high dimensions or even multi-materials part manufacturing.It will deal with the adaptation of raw materials (ceramic powders) to the existing machine, especially in the case of powder flowability and optical absorption. Indeed, the powder flowability enables its transportation up to the laser nozzle, while the optical absorption of the laser signal is necessary to allow its melting.In parallel, the existing machine also needs to be adapted to ceramic materials : the main difficulty of this work will be the occurence of cracks during the manufacturing. This phenomena is due to the local heating by the laser and the materials brittleness. That’s why some secondary heating solutions, before or after the melt, will have to be defined to decrease the thermal gradient in the material while processing. Those solutions will be discussed between Onera and Irepa Laser, based on FEM simulations established with COMSOL Multiphysics software.Finally, the elaboration process influence on the manufactured ceramics parts will be investigated with microscopy, mechanical and thermal characterization
APA, Harvard, Vancouver, ISO, and other styles
5

Gonçalves, Luciano de Souza. "Resistencia da união a microtração de sistemas adesivos em função da remoção de colageno em dentes bovinos." [s.n.], 2007. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290105.

Full text
Abstract:
Orientador: Simonides Consani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-08T12:54:56Z (GMT). No. of bitstreams: 1 Goncalves_LucianodeSouza_M.pdf: 2259891 bytes, checksum: b20e173fcec2e3d501d6548d1bae0f29 (MD5) Previous issue date: 2007
Resumo: O objetivo deste estudo foi avaliar dois sistemas adesivos (Prime & Bond 2.1 - PB2.1 e Prime & Bond NT - PBNT) aplicados sobre a dentina de dentes bovinos com prévia aplicação de solução de hipoclorito de sódio (NaOCl) a 10% por um minuto, por meio do teste de resistência de união a microtração em corpos-de-prova submetidos ou não à ciclagem mecânica e degradação hídrica. Quarenta incisivos centrais bovinos tiveram as coroas seccionadas e aleatoriamente separados em oito grupos. O desgaste da área a ser unida foi feito com lixas de granulação 600 e as amostras incluídas em cilindros de PVC. Nos grupos submetidos à ciclagem mecânica, a simulação do ligamento periodontal foi feita com elastômero à base de poliéter. As coroas foram confeccionadas com o compósito TPH Spectrum em incrementos de aproximadamente 2mm de espessura, com fotoativação de 20s por incremento, até completar 5,0mm de altura, sendo os grupos sem ciclagem mecânica: G1 - sistema adesivo PB2.1, G2 - sistema adesivo PBNT, G3 - sistema adesivo PB2.1 após tratamento com hipoclorito de sódio 10% por 60s e lavagem com água por 30s, e G4 - sistema adesivo PBNT após tratamento com hipoclorito de sódio 10% por 60s e lavagem com água por 30s. O mesmo tratamento foi realizado nos dentes dos grupos G5, G6, G7 e G8, submetidos a 50.000 ciclos mecânicos, após armazenagem por 24 horas. As amostras foram armazenadas por 24 horas em ambiente a 37ºC com umidade relativa de 100% e depois seccionados para a obtenção dos palitos, com secção lateral de 0,8mm. O ensaio foi realizado numa máquina universal. Metade dos palitos de cada amostra foi armazenada por 60 dias em água destilada a 37ºC, para observação dos efeitos da degradação hídrica. Os padrões de fratura foram observados em Microscópio Eletrônico de Varredura (110x). Os resultados obtidos (MPa) foram: G1a - 29,69 (6,63), G2a - 47,82 (4,70); G3a - 50,66 (9,14); G4a - 52,42 (11,82); G5a - 31,79 (10,73); G6a - 32,74 (9,62); G7a - 42,56 (7,52) e G8a - 43,34 (16,75) para os grupos ensaiados após 24 horas. Para os grupos após 60 dias, os resultados foram: G1b - 11,49 (4,22); G2b - 31,49 (5,76); G3b - 46,50 (13,66); G4b - 48,78 (7,73); G5b - 15,05 (6,85); G6b - 17,05 (7,18); G7b - 43,36 (7,26) e G8b 48,83 (12,22). Os valores foram submetidos à análise estatistica. O tratamento com hipoclorito de sódio mostrou valores estatisticamente semelhantes para o teste de resistência de união à microtração com ambos adesivos, quando os tempos 24 horas e 60 dias foram comparados, nos grupos ciclados ou não. Os grupos não tratados com NaOCl apresentaram valores estatisticamente inferiores após o armazenamento por 60 dias, quando comparado com os grupos após 24 horas. Dentro das limitações do estudo foi possível concluir que o tratamento com NaOCl aumentou os valores de resistência da união dos adesivos PB2.1 e PBNT testados 24 horas após a confecção das restaurações. Os grupos desproteinizados apresentaram-se menos suceptiveis a degradação hídrica quando comparados aos grupos restaurados com a técnica adesiva convencional
Abstract: The aim of this study was to evaluate the microtensile bond strength of two adhesive systems (Prime & Bond 2.1 - PB2.1 and Prime & Bond NT - PBNT) applied to bovine dentin previously treated with 10% sodium hypochlorite (NaOCl) solution. Specimens were submitted or not to mechanical cycling and hydrolytic degradation. Crowns of forty central incisors were seccioned and were randomly assigned to eight groups. Surface flattening of the area to be bonded was performed with 600-grit silicon carbide paper, and teeth were then embedded in PVC cylinders. For mechanical cycling groups, simulation of periodontal ligament was carried out with polyether-based elastomeric impression material. A 5-mm layer of resin was build up on the flattened surface using TPH Spectrum composite, adding 2-mm increments at a time, photocured for 20s. Groups not submitted to mechanical cycling: G1 - PB2.1; G2 - PBNT; G3 - PB2.1 after treatment with 10% NaOCl for 60s and rinsing with water for 30s; and G4 - PBNT after treatment with 10% NaOCl for 60s and rinsing with water for 30s. The same was conducted in groups G5, G6, G7 and G8, which were submitted to 50,000 mechanical cycles 24h after restorative procedures. After cycling, the specimens were stored at 37º C for 24h, and 100% relative humidity, and then sectioned to obtain 0.8mm-thick beams. Instron machine was used to test microtensile bond strength, at a crosshead speed of 0.5mm/min. Half of the beams were stored at 37º C for 60 days in distilled water, which was changed every week, to observe hydrolytic degradation effects. Fracture patterns were observed under scanning electron microscopy (110x). Results for the bond strength (MPa) at 24h were G1a -29.69 (6.63), G2a - 7.82 (4.70); G3a - 50.66 (9.14); G4a - 52.42 (11.82); G5a - 31.79 (10.73); G6a - 32.74 (9.62); G7a -42.56 (7.52) e G8a - 43.34 (16.75). For the groups tested after 60 days, the results were G1b - 11.49 (4.22); G2b -31.49 (5.76); G3b - 46.50 (13.66); G4b - 48.78 (7.73); G5b - 15.05 (6.85); G6b - 17.05 (7.18); G7b - 43.36 (7.26) e G8b 48.83 (12.22). Data were submitted to statistics analisys . For both adhesives, specimens treated with NaOCl showed no statistically difference bond strength values for the 24-h test period when compared to the 60-day period, considering groups submitted or not to mechanical cyclying. Untreated groups showed statistically lower values after 60 days compared to 24h. Within the limitations of this study, it was concluded that the treatment with NaOCl increased the bond strength values of Prime & Bond 2.1 and Prime & Bond NT tested 24h after preparation of the specimens. The groups submitted to deproteinization were found to be less susceptible to hydrolytic degradation when compared to groups restored using the conventional adhesive technique
Mestrado
Materiais Dentarios
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
6

Carvalho, Cláudio Antonio Talge. "Avaliação in vitro da resistência estrutural em dentes fragilizados utilizando reforços intra-radiculares /." São José dos Campos, 2002. http://hdl.handle.net/11449/114073.

Full text
Abstract:
Orientador: Marcia Carneiro Valera
Banca: Silvia Lustosa de Castro
Banca: Maria Antonia Pereira
Banca: Alberto Siqueira e Silva
Banca: Ana Paula Martins Gomes
Resumo: Dentes com rizogênese incompleta quando sofrem trauma com conseqüente necrose pulpar permanecem com suas paredes dentinárias finas e fragilizadas, tornando-se mais suscetiveis a reincidências de fraturas. A proposta deste trabalho foi avaliar através do teste de compressão a resistência à fratura de dentes bovinos fragilizados que receberam reforços intra-radiculares com resina composta ou pino de fibra de zircônia. Para tanto, utilizou-se 56 dentes bovinos, os quais tiveram suas coroas seccionadas padronizando o tamanho das raízes em 30mm. Os dentes foram divididos em quatro grupos experimentais (14 dentes} e, com exceção do grupo 04 (Controle negativo), todos os canais radiculares foram preparados biomecanicamente até o instrumento de nº 80 e alargados com brocas Gates-Glidden nos 3, 4, 5 e 6 até 20mm de profundidade. A porção coronária foi alargada com broca diamantada tronco cônica nº 721 até a junção cemento-esmalte vestibular e, com broca diamantada tronco cônica nº 716, realizou-se a fragilização das paredes dentinárias do canal radicular a 20mm de profundidade, deixando aproximadamente 2mm de espessura em cada parede. Após, as raízes foram divididas em grupos: grupo 01-receberam reforço intra-radicular com resina composta, fotopolimerizada com o auxílio do sistema Luminex , seguida da obturação do canal; grupo 02-obturação do canal deixando os 10mm apicais com material obturador, e reforço intra-radicular com pino de fibra de zircõnia cimentado com cimento resinoso; o grupo 03-(Controle positivo) não recebeu reforço intra-radicular e foi obturado pela técnica da condensação lateral ativa; no grupo 04-(Controle negativo), os dentes não foram fragilizados. Os espécimes foram embutidos em blocos metálicos, os quais foram adaptados a um dispositivo cilíndrico, de modo que os espécimes foram fixados a 45°. Este dispositivo foi adaptado a um...
Abstract: lmmature teeth when suffer trauma with consequent necrosis pulpar they stay with its dentinal walls thin and brittle, becoming more susceptible to the second injuries. The purpose of this work is to evaluate through the compression test, the resistance to fracture of teeth bovine brittleness that received reinforcements within the root canal with composite resin or pins of zircônia fiber. lt was used 56 bovine teeth, which had its crowns sectioned in the medium third standardizing the size of the specimens in 30mm of length. The teeth were divided in four experimental groups (14 teeth) and, except for the group 04 (negative control), all the root canal was instrumented to #80 and enlarged firstly with drills Gates-Glidden numbers 3, 4, 5 and 6 to 20mm of depth, after, lhe coronary portion was enlarged with the conical drill number 721 until the cementoenamel junction facial and, with lhe conical drill number 716, the brittleness of the dentinal walls of the root canal at 20mm of depth, leaving 2mm of thickness approximately in each wall. After, the specimens of the group 01 received reinforcement within the root canal with composite resin, that was cured by aid of the Luminex system and, after, they were obturated; in lhe group 02, the specimens were obturated. Just leaving the 10mm apical with material, and they received reinforcement within the root canal with zircônia fiber pins cemented with resinous cement; the group 03 (positive control) it didn't received reinforcement within the root canal and it was obturated by the technique of the active lateral condensation; in the group 04 (negative control), the teeth were not brittleness. After, all the specimens were embedded with acrylic resin chemically activated, in metallic blocks, which were adapted to a cylindrical device, so that the specimens were fractured by load in angle of 45°. This device was adapted to a lnstron machine, ...
Doutor
APA, Harvard, Vancouver, ISO, and other styles
7

Galetti, Roberta 1985. "Análise da resistência da união de sistemas adesivos à dentina de dentes submetidos à radioterapia in vivo." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288156.

Full text
Abstract:
Orientador: Mario Fernando de Goes
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-17T23:45:11Z (GMT). No. of bitstreams: 1 Galetti_Roberta_M.pdf: 1687550 bytes, checksum: 5c4f4c530954698741e89cea1c241dfc (MD5) Previous issue date: 2011
Resumo: Este estudo avaliou a resistência da união à dentina de dentes de pacientes que foram submetidos à radioterapia. Foram utilizados dezoito incisivos humanos extraídos de pacientes saudáveis (grupo controle) e dezoito incisivos de pacientes submetidos à radioterapia. As superfícies vestibulares de cada dente foram desgastadas para remover o esmalte e expor a dentina. Os dentes foram aleatoriamente distribuídos em três grupos experimentais de acordo com o sistema adesivo aplicado: Single Bond 2 (SB2) (3M ESPE), Easy One (EO) (3M ESPE) and Clearfil SE Bond (CSE) (Kuraray). Os sistemas adesivos foram aplicados na superfície preparada de acordo com as instruções do fabricante e restaurados usando um compósito resinoso (Filtek Supreme, 3M ESPE). Após estocagem em água deionizada por 24 horas (37°C), os dentes foram seccionados no sentido longitudinal (mesio-distal e vestíbulo-lingual) para obter espécimes com uma aparência similar a palitos com área de 0,8 mm2 (±0,1mm2). Os espécimes foram tracionados usando uma máquina de teste universal (Instron 4411, Corona, CA, USA) com célula de carga de 500N a uma velocidade de 0,5 mm/min. Os padrões de fratura foram observados em MEV (JEOL, JSM - 5600 LV, Scanning Electron Microscope, Tokyo, Japan). Os dados foram analisados pelo teste ANOVA para dois fatores (p?0,05). Nenhuma diferença estatística significativa foi encontrada entre os sistemas adesivos e entre os grupos de dentes irradiados in vivo (SB= 44,66±10.12; EO= 41,48±12.71; CSE= 46,01±6.98) e grupo controle (SB= 39,12±9.51; EO= 42,40±6.66; CSE= 36,58±7.06). Todos os grupos apresentaram predominantemente padrão de fratura mista, com fraturas na base da camada híbrida, coesiva na camada híbrida e coesiva no adesivo. A radioterapia realizada in vivo não afetou a resistência de união à dentina aos sistemas adesivos utilizados no estudo
Abstract: This study evaluated the influence of irradiation on dentin bond strength of the extracted teeth of patients who underwent radiotherapy. Eighteen caries-free human incisors were extracted from healthy patients (control group) and eighteen incisors from patients submitted to radiotherapy. The buccal surfaces of each tooth were grounded to remove enamel and expose dentin. Teeth were randomly assigned to three experimental groups according to the adhesive system employed: Single Bond 2 (SB2) (3M ESPE), Easy One (EO) (3M ESPE) and Clearfil SE Bond (CSE) (Kuraray). The adhesive systems were applied to the prepared surface according to manufacturers' instructions and were restored using composite resin (Filtek Supreme, 3M ESPE). After 24 hours in deionized water storage (37oC), teeth were longitudinal (mesio-distal and buccal-lingual) cut to obtain beam specimens with a cross-section area of 0.8 (± 0.1mm2). Specimens were tested in tension using a universal testing machine (Instron 4411, Corona, CA, USA) with 500 N load cell at a cross-speed of 0.5mm/min. Fracture patterns were observed under SEM (JEOL, JSM - 5600 LV, Scanning Electron Microscope, Tokyo, Japan). Data were analyzed by Two-way ANOVA (p?0.05). No statistically significant difference was found among adhesive systems or between the irradiated group in vivo (SB= 44.66±10.12; EO= 41.48±12.71; CSE= 46.01±6.98) and the control group (C/SB= 39.12±9.51; C/EB= 42.40±6.66; C/CSE= 36.58±7.06). All groups presented a predominance of mix fractures with the hybrid layer inner base, cohesive in hybrid layer and cohesive in adhesive. Radiotherapy in vivo did not affect dentin bond strength for the adhesive materials tested in this study
Mestrado
Materiais Dentarios
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
8

Carvalho, Cláudio Antonio Talge [UNESP]. "Avaliação in vitro da resistência estrutural em dentes fragilizados utilizando reforços intra-radiculares." Universidade Estadual Paulista (UNESP), 2002. http://hdl.handle.net/11449/114073.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-05-07Bitstream added on 2015-01-26T13:30:16Z : No. of bitstreams: 1 000153365.pdf: 4243096 bytes, checksum: 4ac8a630a1606f01e62807e3baafb495 (MD5)
Dentes com rizogênese incompleta quando sofrem trauma com conseqüente necrose pulpar permanecem com suas paredes dentinárias finas e fragilizadas, tornando-se mais suscetiveis a reincidências de fraturas. A proposta deste trabalho foi avaliar através do teste de compressão a resistência à fratura de dentes bovinos fragilizados que receberam reforços intra-radiculares com resina composta ou pino de fibra de zircônia. Para tanto, utilizou-se 56 dentes bovinos, os quais tiveram suas coroas seccionadas padronizando o tamanho das raízes em 30mm. Os dentes foram divididos em quatro grupos experimentais (14 dentes} e, com exceção do grupo 04 (Controle negativo), todos os canais radiculares foram preparados biomecanicamente até o instrumento de nº 80 e alargados com brocas Gates-Glidden nos 3, 4, 5 e 6 até 20mm de profundidade. A porção coronária foi alargada com broca diamantada tronco cônica nº 721 até a junção cemento-esmalte vestibular e, com broca diamantada tronco cônica nº 716, realizou-se a fragilização das paredes dentinárias do canal radicular a 20mm de profundidade, deixando aproximadamente 2mm de espessura em cada parede. Após, as raízes foram divididas em grupos: grupo 01-receberam reforço intra-radicular com resina composta, fotopolimerizada com o auxílio do sistema Luminex , seguida da obturação do canal; grupo 02-obturação do canal deixando os 10mm apicais com material obturador, e reforço intra-radicular com pino de fibra de zircõnia cimentado com cimento resinoso; o grupo 03-(Controle positivo) não recebeu reforço intra-radicular e foi obturado pela técnica da condensação lateral ativa; no grupo 04-(Controle negativo), os dentes não foram fragilizados. Os espécimes foram embutidos em blocos metálicos, os quais foram adaptados a um dispositivo cilíndrico, de modo que os espécimes foram fixados a 45°. Este dispositivo foi adaptado a um...
lmmature teeth when suffer trauma with consequent necrosis pulpar they stay with its dentinal walls thin and brittle, becoming more susceptible to the second injuries. The purpose of this work is to evaluate through the compression test, the resistance to fracture of teeth bovine brittleness that received reinforcements within the root canal with composite resin or pins of zircônia fiber. lt was used 56 bovine teeth, which had its crowns sectioned in the medium third standardizing the size of the specimens in 30mm of length. The teeth were divided in four experimental groups (14 teeth) and, except for the group 04 (negative control), all the root canal was instrumented to #80 and enlarged firstly with drills Gates-Glidden numbers 3, 4, 5 and 6 to 20mm of depth, after, lhe coronary portion was enlarged with the conical drill number 721 until the cementoenamel junction facial and, with lhe conical drill number 716, the brittleness of the dentinal walls of the root canal at 20mm of depth, leaving 2mm of thickness approximately in each wall. After, the specimens of the group 01 received reinforcement within the root canal with composite resin, that was cured by aid of the Luminex system and, after, they were obturated; in lhe group 02, the specimens were obturated. Just leaving the 10mm apical with material, and they received reinforcement within the root canal with zircônia fiber pins cemented with resinous cement; the group 03 (positive control) it didn't received reinforcement within the root canal and it was obturated by the technique of the active lateral condensation; in the group 04 (negative control), the teeth were not brittleness. After, all the specimens were embedded with acrylic resin chemically activated, in metallic blocks, which were adapted to a cylindrical device, so that the specimens were fractured by load in angle of 45°. This device was adapted to a lnstron machine, ...
APA, Harvard, Vancouver, ISO, and other styles
9

Penina, Patricia de Oliveira. "Análise microscópica de capeamento pulpar direto com diferentes materiais em dentes humanos." Universidade do Estado do Rio de Janeiro, 2007. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=562.

Full text
Abstract:
O capeamento pulpar direto busca preservar a vitalidade pulpar. Este trabalho apresenta a resposta tecidual de polpas humanas ao capeamento pulpar direto com o Agregado de Trióxido Mineral (MTA) comparado com o hidróxido de cálcio. Foram utilizados 20 pré-molares de dez pacientes com extração indicada para tratamento ortodôntico. Todos os dentes apresentavam vitalidade pulpar e neles foram feitos capeamentos pulpares diretos com MTA ou com o hidróxido de cálcio. Os dentes foram extraídos num período de 14 dias ou 45 dias, estabelecendo os seguintes grupos experimentais: Ca(OH) 14 dias; Ca(OH) 45 dias; MTA 14 dias e MTA 45 dias. Estes dentes foram analisados microscopicamente por dois examinadores treinados. Os dados obtidos foram tabulados, utilizando-se o teste Kappa para observar o grau de concordância entre os examinadores. Para avaliação comparativa entre as respostas citotóxicas dos materiais testados foi aplicado o teste não paramétrico Kruskal-Wallis e o teste de Dunn para comparações individuais e identificação da significância dos achados. Na análise dos resultados não houve diferença estatisticamente significante entre os grupos nos períodos experimentais de 14 e 45 dias, e nem na resposta inflamatória pulpar frente ao hidróxido de cálcio quando comparado ao MTA. Quanto à espessura e à organização da barreira dentinária reparatória com o hidróxido de cálcio, quando comparado com o MTA também não apresenta diferença estatisticamente significante. Conclui-se que o MTA satisfaz os requisitos de um material capeador pulpar em dentes de humanos, apresentando propriedades físicas e biológicas que o indicam para este tratamento.
The direct dental pulp capping aims to preserve the pulp vitality. This work shows the tissue response from human pulps to that procedure with the Mineral Trioxide Agregate (MTA) compared to calcium hydroxide - Ca(OH)2. Twenty premolars from 10 patients with extraction indicated to orthodontic treatment were used. All teeth showed pulp vitality and were treated with direct dental pulp capping with MTA or with calcium hydroxide. The teeth have been extracted within 14 or 45 days, stablishing the following experimental groups: Ca(OH)2 14 days; Ca(OH)2 45 days; MTA 14 days; and MTA 45 days. These teeth were analyzed under microscopy by two observers trained. The data obtained were put in table using the Kappa test to note the agreement degree between the observers. For the comparative assessment between the citotoxic response from material tested has been applied the non-paired Kruskal-Wallis test, and the Dunns test for individual comparisons and identifying the significance of findings. In the analysis of results there had no statistically significant difference between the groups in experimental periods of 14 days and 45 days, not even in the pulp inflammatory response to calcium hydroxide when compared to MTA. The thickness and arrangement of the healing dentin barrier faced with calcium hydroxide, when compared to MTA, also showed no statistically significant difference. It may be concluded that the MTA fulfils the requirements of pulp capping material in human teeth showing biological and physical properties that indicate it for this treatment.
APA, Harvard, Vancouver, ISO, and other styles
10

Lopes, Murilo Baena. "Analise estrutural e mecanica de dentes bovinos relacionados a testes de união adesiva." [s.n.], 2007. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290104.

Full text
Abstract:
Orientador: Simonides Consani
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-08T11:55:44Z (GMT). No. of bitstreams: 1 Lopes_MuriloBaena_D.pdf: 3468611 bytes, checksum: 9606e712f2290f8675f6224ff08a51a6 (MD5) Previous issue date: 2007
Resumo: O propósito deste estudo foi: 1 - Comparar os valores de resistência de união esmalte e dentina humanos com os valores obtidos em dentes bovinos, utilizando dois sistemas de união com princípios de atuação distintos; 2 -Comparar as dimensões tubulares e distribuição na dentina humana e bovina; 3-Comparar duas técnicas (confocal e microscopia óptica) para determinar a microinfiltração em dentes bovinos e humanos para sistemas adesivos. Para o teste de resistência de união, a dentina e o esmalte humano e bovino apresentaram valores equivalentes para o Clearfil Liner Bond 2V. O Scotchbond Multi-Purpose não mostrou diferença estatística em esmalte, porém em dentina o substrato bovino mostrou maiores valores de união que o humano. Quando analisado o diâmetro tubular, a dentina bovina superficial e média mostrou diâmetros estatisticamente maiores que para a dentina humana superficial e média. Não se encontrou diferença estatística entre o diâmetro tubular em dentina humana e bovina em dentina profunda. A densidade dos túbulos dentinários foi estatisticamente maior em dentina humana que em dentina bovina. No teste de microinflitração, quando dente bovino foi utilizado, o Scotchbond apresentou estatisticamente mais infiltração que o Clearfil. Para o dente humano não foi encontrada diferença estatística. Quando escores foram analisados, o Scotchbond não apresentou diferenças para o Clearfil, entretanto este apresentou estatisticamente menos infiltração em dente bovino que em dente humano quando o microscópio óptico foi utilizado. Microscópio confocal mostrou maior especificidade para o corante e limites de microinfiltração mais nítidos. Com o substrato bovino nem sempre se encontrou resultados equivalentes em teste de união com o dente humano. A estrutura dentinária mostrou-se diferente entre dentes humanos e bovinos. O dente bovino não seria o mais adequado para testes de microinfiltração
Abstract: The purpose of this study was: 1 - To compare shear bond strength values obtained in human enamel and dentin with the values obtained in bovine teeth using two adhesive systems with different actions; 2- To compared the tubular dimensions and distribution of human dentine and bovine dentine; 3 - To compare two techniques (confocal and optical microscopies) for determining microleakage in human and bovine teeth for adhesive bond systems. For shear bond strength, the bovine and the human dentin and enamel had equivalent values for Clearfil Liner Bond 2V. Scotchbond Multi-Purpose had no statistical differences on enamel, but on dentin, the bovine substrate showed higher bond strength values than the human one. Bovine dentine tubular diameter for superficial and middle dentine was significantly greater than for human superficial and middle dentine. There was no significant difference in tubular diameter between human and bovine deep dentine. The density of dentine tubules is significantly greater in human dentine than in bovine dentine. When bovine teeth were used, Scotchbond showed statistically higher mean penetration than Clearfil. When human teeth were used no difference was found. For microleakage test, when bovine teeth were used, Scotchbond showed statistically higher mean penetration than Clearfil. When human teeth were used no difference was found. When scores were analyzed, Scotchbond showed no difference to Clearfil, however Clearfil showed statistically less infiltration in bovine teeth than in human teeth when optical microscopy was used. Confocal microscopy showed higher sensibility for the stain and clearer leakage limits. The bovine teeth not always show the same pattern of results of human teeth in shear bond test. The dentinal structure showed different between human and bovine substrates. Bovine teeth may be not suitable for adhesive microleakage tests
Doutorado
Materiais Dentarios
Doutor em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
11

Naoe, Hilka Tiemi. "Influencia dos tipos de tratamentos sobre a resistencia de união entre dentes e resinas acrilicas." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288557.

Full text
Abstract:
Orientador: Rafael Leonardo Xediek Consani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-12T19:07:37Z (GMT). No. of bitstreams: 1 Naoe_HilkaTiemi_M.pdf: 1024541 bytes, checksum: 92dfb7adacf4acd2b08826fb3278ce7c (MD5) Previous issue date: 2009
Resumo: O objetivo neste estudo foi verificar a resistência da união ao cisalhamento entre as resinas acrílicas Clássico ou Onda-Cryl e o dente Trubyte-Biotone, sob a influência de diversas formas de retenção, compreendendo nenhum tratamento (controle), perfuração com broca, jateamento com partículas de óxido de alumínio, condicionamento com monômero, condicionamento com primer e interações. Noventa matrizes retangulares, medindo 20mm de largura por 35mm de comprimento, foram confeccionadas com cera utilidade e incluídas na parte inferior de muflas metálicas ou plásticas, com gesso pedra tipo III Herodent. As matrizes retangulares foram removidas depois de plastificadas com água em ebulição e os moldes de gesso revestidos com silicone laboratorial, nos quais foram incluídos um dente molar com a base contendo um cilindro de cera de 6mm de diâmetro por 25mm de comprimento. O conjunto dente-cilindro em cera foi recoberto com uma camada de silicone e a mufla preenchida com gesso pedra. Depois da presa do gesso, o conjunto dente-cilindro em cera foi removido, o bastão em cera retirado, o dente limpo com detergente e as bases submetidas aos tratamentos de acordo com o protocolo e recolocadas nos moldes de silicone. As resinas acrílicas termopolimerizáveis foram proporcionadas na relação volumétrica de 3/1 (polímero/monômero), adaptadas na fase plástica nos moldes de silicone e prensadas em prensa hidráulica de bancada. As muflas metálicas foram levadas à termopolimerizadora automática para polimerização da resina no ciclo em banho de água à temperatura de 74ºC durante 9 horas. As muflas plásticas foram colocadas em forno de microondas para polimerização da resina, calibrado com 900W de potência, para o ciclo de: fase I - 3 minutos com 40% da potência, fase II - 4 minutos com potência 0% e fase III - 3 minutos com 90% da potência e esfriamento das muflas em bancada. Depois da demuflagem, os corpos-de-prova foram armazenados em água destilada à temperatura de 37ºC durante 24 horas. Depois da armazenagem, os corpos-de-prova foram submetidos ao teste de resistência ao cisalhamento na máquina de ensaios universal Instron, com velocidade de 1mm/minuto. Os resultados submetidos à análise de variância e as médias ao teste de Tukey (5%) mostraram que os valores da união entre dentes artificiais e resinas acrílicas não apresentam diferença estatística significativa, quando comparadas independentemente dos tipos de tratamentos. Na análise dos tipos de tratamentos, independentemente da resina acrílica, o grupo que recebeu jateamento+adesivo apresentou média com diferença estatística significativa com o grupo perfurado+adesivo. Os demais grupos não apresentaram diferença estatística significativa. Quando os tratamentos foram considerados em cada resina, na Clássico não houve diferença significativa entre eles e na Onda-Cryl os tratamentos controle e perfurado+adesivo foram diferentes estatisticamente dos grupos jateado+ monômero e jateado+adesivo. Os demais grupos não apresentaram diferenças estatísticas. Na comparação entre resinas, somente o grupo controle apresentou diferença estatística significativa com o maior valor para a resina Onda-Cryl
Abstract: The purpose of this study was to verify the shear bond strength between denture tooth Trubyte-Biotone and the acrylic resins Clássico and Onda-Cryl, under the influence of various forms of treatments, including no treatment (control), retention groove, sandblasting with aluminum oxide particles, monomer application, primer application, and interactions. Ninety wax rectangular mold patterns (20 mm in width and 35 mm in length), were poured into a traditional brass flask or metal with type III dental stone that was proportioned and manipulated following the manufacturer's recommendations. After wax patterns removal, the stone mold was filled with a layer of laboratory silicone putty. Identical model acrylic molar teeth with a wax stick (6mm diameter and 25mm long) attached at the ridge lap surface were partially embedded into the silicone layer. The resultant tooth/wax stick set was then covered with a layer of laboratory silicone putty. After dental stone isolation with petroleum jelly, the flask was completely poured with type III dental stone and pressed in a hydraulic press bench. Following, the tooth/wax stick set was deflasked and the wax stick removed from the tooth ridge lap. The tooth was brushed with a solution of hot water and liquid detergent to eliminate the wax residuos. Heat-cured denture base acrylic resins were prepared using a ratio of volume 3/1(polymer/monomer), adapted on stage in plastic molds made of silicon and pressing into bench hydraulic press. The metal flask were conventional packed, polymerized in a hot water bath at 74oC for 9 hours in polymerizing unit, and deflasked after flask cooling at room temperature. The plastic flask were placed in the microwave oven for curing the acrylic resin, calibrated with 900W of power for the cycle: Phase I - 3 minutes with 40% of the power, phase II - 4 minutes with 0% power and phase III - 3 minutes with 90% of the power and flask cooling at room temperature. After deflasked, all specimens were stored in distilled water at a temperature of 37oC for 24 hours, and they were performed the shear bond testing in an Instron machine, using a cross-speed of 1mm/minuto. The results were submitted to ANOVA and Tukey's test (5%) showed that the values of the shear bond strength between artificial teeth and acrylic resins were not statistically significant when compared regardless of the types of treatments. In the treatment type analysis, regardless of acrylic resin, the sandblasting+adhesive group showed bond strength values with significant statistically difference when compared to groove+adhesive group. The other experimental groups were not statistically different. When the treatments were considered in each resin, in the Classico acrylic resin there was no significant difference between them. In Onda-Cryl, control and groove+adhesive treatments were statistically different of the sandblasting+monomer and sandblasting+adhesive groups, while the other showed no statistical differences. In the comparison between resins, only the control group showed statistically significant differences, with the greatest value for the Onda-Cryl acrylic resin
Mestrado
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
12

Bowman, Elisabeth Therese. "The ageing and creep of dense granular materials." Thesis, University of Cambridge, 2002. https://www.repository.cam.ac.uk/handle/1810/251841.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Cortez, Douglas Giordani Negreiros. "Estudo in vivo da infiltração coronaria em dentes de cães tratados endodonticamente e protegidos por diferentes materiais." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289868.

Full text
Abstract:
Orientador: Alexandre Augusto Zaia
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T22:23:00Z (GMT). No. of bitstreams: 1 Cortez_DouglasGiordaniNegreiros_D.pdf: 24105426 bytes, checksum: d2a6f958d2f989ae6e14ff197ec69f42 (MD5) Previous issue date: 2005
Resumo: Este trabalho avaliou in vivo a infiltração coronária de microrganismos em dentes tratados endodonticamente, preparados para pino e com o remanescente obturador protegido ou não com diferentes materiais. Foram utilizados 136 canais de incisivos e pré-molares de 6 cães. Após a anestesia dos animais, os canais foram instrumentados. Cento e dois canais foram obturados pela técnica da condensação lateral.com cimento Sealapex e 34 canais foram obturados por .cone único de guta percha sem cimento. Em 68 canais obturados pela condensação lateral e nos 34 canais obturados sem cimento as obturações foram parcialmente removidas deixando um remanescente padronizado de 4mm. Diretamente sobre os remanescentes obturadores foram realizadas proteções com espessura de 2mm com: Coltosol ou resina composta "flow". Os demais canais tiveram as obturações parcialmente removidas deixando-as com 6mm e não receberam proteção. Os canais foram divididos em 8 grupos de 17 cada distribuídos da seguinte maneira: - grupos 1 e 5: proteção com resina composta flow; - grupos 2 e 6: proteção com Coltosol; - grupos 3 e 7: proteção com coltosol nas raízes obturadas com cone único sem cimento; - grupos 4 e 8: sem proteção. Devidamente preparados, os espécimes permaneceram com as obturações expostas à cavidade oral dos animais. Os grupos 1 a 4 foram avaliados -com 30 dias de exposição e os grupos 5 a 8 com 180 dias. Decorridos os tempos experimentais os animais foram mortos. Todos os espécimes foram avaliados radiograficamente quanto ao aparecimento de lesão periapical. Em cada grupo, 11 raízes destinadas ao estudo histológico foram removidas em bloco e devidamente processadas para histologia. Os demais espécimes foram extraídos e destinados a pesquisa da presença bacteriana por dois métodos, onde 3 raízes foram destinadas à cultura microbiológica e outras 3 foram clivadas transversalmente para a análise em Microscopia Eletrônica de Varredura (MEV). Radiograficamente não foi detectada lesão periapical em nenhum espécime. Na avaliação microbiológica apenas um espécime do grupo 7 apresentou -crescimento bacteriano. A avaliação em MEV não demonstrou infiltração bacteriana. Histologicamente com 30 dias nenhum espécime apresentou inflamação relacionada à infiltração coronária. Com ô meses o grupo 5 apresentou 2 espécimes com inflamação relacionada à infiltração coronária, os demais grupos apresentaram apenas 1 espécime cada com inflamação. A coloração de Brown e Brenn evidenciou microrganismos nos espécimes com inflamação. Os resultados permitiram concluir que o Coltosol foi eficiente na proteção das obturações e que a obturação do canal apresenta uma boa resistência à infiltração coronária in vivo por 180 dias
Abstract: This in vivo study evaluated the microbial coronal leakage in dogs endodontically treated teeth, post space preparation and with the remaining filling protected or not with different materiais. A hundred thirty six root canais of incisives and pre-molars of 6 dogs were used. After the anesthesia of the animais, these teeth were endodontically prepared. Hundred two canaIs were filled by lateral condensation technique and Sealapex sealer, and 34 canais were filled only with a single gutta-percha cone without sealer. In 68 canais filled by lateral-condensation and in the 34 canais filled without sealer, the fillings were partially removed leaving standardized 4mm. Directly on the remaining obturations, protections with 2mm of thickness were done with Coltosol or Composite " flow ". The obturations of the other canais were partially removed leaving them with 6mm and didn't receive protection. The canais were divided in 8 groups of 17 .each distributed in the following way: - groups 1 and 5: protection with composite flow; - groups 2 and 6: protection with Coltosol; - groups 3 and 7: protection with coltosol in the roots filled with a single cone without sealer; - groups 4 and 8: without protection. Properly prepared, the specimens stayed with the fillings exposed to the oral cavity of the animais. The groups 1 to 4 were evaluated with 30 days of exposition and the groups 5 to 8 with 180 days. In the end of the experimental times the animais were killed. Ali the specimens were radiographically appraised about the appearance of periapical lesions. In each group, 11 roots destined to the histological evaluation were removed in block and properly processed for histology. The other specimens were extracted and destined to bacterial research by two methods. In 3 roots microbiologic culture was accomplished and the other 3 were transverselly fractured to Scanning Electronic Microscopy (SEM) analysis. Periapicallesion was not radiographically detected in any specimen. In the microbiologic evaluation only one specimen of the group 7 presented bacterial growth. The SEM evaluation did not demonstrate bacterial leakage. Histologically, at 30 days, no -specimen presented inflammation related to coronal leakage. With 6 months the group 5 presented 2 specimens with inflammation related to the coronal leakage, the other groups presented only 1 specimen each with inflammation. The Brown and Br.enn stain evidenced microrganisms in the specimens with inflammation. The r.esults allowed to conclude that Coltosol was efficient in the protection of the obturations and that theroot canal filling presents a good resistance to coronalleakage in vivo up to 180 days
Doutorado
Endodontia
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
14

Andreatta, Filho Osvaldo Daniel [UNESP]. "Avaliação da resistência adesiva entre um cimento resinoso e ligas para metalo-cerâmica submetidas a dois diferentes condicionamentos de supefície." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/114079.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-12Bitstream added on 2015-01-26T13:30:14Z : No. of bitstreams: 1 000436713.pdf: 7731647 bytes, checksum: 9b7aadb95aa028efeda85c7c4760387c (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O objetivo deste estudo foi avaliar a hipótese de que diferentes condicionamentos de superfície de três ligas para próteses metalo-cerâmica (Ouro - Degudent U – Degussa; Níquel-Cromo - Wiron 99, Bego; Titânio - Rematitan, Dentaurum) não alteram os valores de resistência adesiva com um cimento resinoso. Vinte blocos de cada liga com dimensões de 5x5x5mm foram fundidos e divididos em dois subgrupos de 10 blocos e condicionados com os seguintes tratamentos de superfície: TRAT. 1 (Primer) – jateamento com partículas de óxido de alumínio 110µm (Al2O3) + Alloy Primer (Kuraray, CO) e TRAT. 2 (Cojet)– jateamento com partículas de sílica com o sistema Cojet (3M/ESPE) + Silano ESPE-Sil (3M/ESPE). Os blocos condicionados de cada grupo foram cimentados com Panavia F (Kuraray, CO) a blocos de resina composta ClearfilTM AP-X (Kuraray, CO) sob carga constante de 750g por 10 minutos. Foram determinados, portanto, seis grupos experimentais constituídos por conjuntos formados pela liga, cimento e resina composta. Estes foram cortados em uma máquina de corte obtendo-se por bloco cimentado 4 amostras com dimensões de 10x1x1mm sendo que a superfície adesiva apresentou aproximadamente 1mm2 de área. O teste de microtração foi realizado em máquina de testes universal (EMIC) com célula de carga de 10kgf e velocidade de 1mm/min. Cada grupo foi representado por quarenta amostras, entretanto cada grupo apresentou 10 valores médios de resistência adesiva em MPa (n=10), sendo que cada valor foi proveniente da média obtida a partir dos valores individuais das quatro amostras de cada conjunto de blocos cimentados. Os valores de resistência adesiva e os desvios-padrão (MPa) para os grupos foram : G1: 7,33 ± 1,93d; G2: 13,35 ± 2,18 c G3: 23,56 ± 6,5 b; G4:42,6 ± 5,84 a; G5: 26,17 ± 1,94 b; G6: 44,30 ± 2,3 a. Os dados de resistência adesiva foram analisados estatisticamente pelo teste de ....
The aim of this study is to evaluate the hypothesis that different conditionings of surface of three dental alloys (Gold - Degudent U – Degussa; Nickel-chromium - Wiron 99, Bego; Titanium - Rematitan, Dentaurum) they do not modify the values of bond strength with a resin cement. Twenty blocks of each alloy with dimensions of 5x5x5mm were cast and divided in two subgroups of 10 blocks that were conditioned with the following surface treatments: TRAT. 1 – sandblasting with particles of oxide of aluminum 110μm (Al2O3) + Alloy Primer (Kuraray, CO) and TRAT. 2 - sandblasting with particles of oxide of silica with Cojet-Sand (3M/ESPE) + Silane (ESPE-SIL). The conditioned blocks of each group were luted with Panavia F (Kuraray, CO) to composite resin blocks of ClearfilTM AP-X (Kuraray, CO) under constant load of 750g for 10 minutes. Six experimental groups were constituted by sets formed by the alloy, cement and composite resin. The sets were split up in a mechanical lathe obtaining by block 4 samples with dimensions of 10x1x1mm and the adhesive surface with approximately 1mm2. The microtensile test was accomplished in an universal test machine (EMIC) with cell of load of 10kgf and crosshead speed of 1mm/min. Each group was represented by forty samples, however each group presented 10 means values of bond strength MPa (n=10), obtained from the mean of the individual values of the four samples of each cemented blocks. Means and standard deviation of bond strength (MPa) were: G1: 7.33 ± 1.93d; G2: 13.35 ± 2.18 c G3: 23.56 ± 6.5 b; G4:42.6 ± 5.84 a; G5: 26.17 ± 1.94 b; G6: 44.30 ± 2.3 a. The data of bond strength were analyzed by the analysis of variance test (ANOVA) and Tukey test, p<0.05. The results indicated that surface treatment 2 (Cojet) increased the bond strength between the resin cement and alloys. The smallest values of bond strength were obtained with gold alloy, independent of ....
APA, Harvard, Vancouver, ISO, and other styles
15

Santos, Paulo Henrique dos. "Avaliação da porosidade interna e da rugosidade de superficie de resinas compostas para dentes posteriores submetidas a escovação." [s.n.], 2000. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290110.

Full text
Abstract:
Orientador: Simonides Consani
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-27T10:02:09Z (GMT). No. of bitstreams: 1 Santos_PauloHenriquedos_M.pdf: 3739962 bytes, checksum: 4f966540d6526543127025aacad09ae1 (MD5) Previous issue date: 2000
Resumo: O objetivo deste estudo foi verificar a porosidade interna, a rugosidade de superficie de resinas compostas para restauração em dentes posteriores submetidas a ensaio mecânico de escovação e a eficácia de métodos de recuperação de lisura superficial. Os materiais utilizados foram as resinas compostas específicas para restauração em dentes posteriores: Prodigy Condensável@ (KerrISybron) e Alert@ (JenericlPentron); resinas compostas para utilização em dentes anteriores e posteriores: Z100@ (3M) e Definite@ (Degussa) e o selante de superficie Protect-It@ (JenericlPentron). Para avaliação da rugosidade de superficie, 10 corpos-de-prova de cada material foram confeccionados à temperatura de 23 ::t 1°e e umidade relativa do ar ambiental de 50 ::t 5% , utilizando uma matriz metálica com 2mm de espessura por 4mm de diâmetro. Após 24 horas, foi realizado o polimento dos materiais utilizando o sistema de acabamento e polimento Sof-Lex@ (3M) e uma das superfícies dos corpos-de-prova foi coberta com o selante de superficie e a outra não. Todos os corpos-de-prova foram levados individualmente ao rugosímetro (Surfcorder SE 1700) para verificação da rugosidade inicial das superfícies, antes de serem submetidos a movimentos lineares de escovação, com velocidade de 250 movimentos por minuto, totalizando 30.000 ciclos por superficie, num período de duas horas. Após este período, foi realizada a segunda leitura da rugosidade em todas as superfícies, sendo que, em seguida, uma delas foi recoberta com selante de superfície e a rugosidade foi novamente aferida. Na outra, foram tomadas mais duas leituras da rugosidade, uma após o repolimento e outra após a aplicação do selante. Para a avaliação da porosidade, os corpos-de-prova de cada material foram seccionados com disco de óxido de silício, incluídos em resina acrílica de ativação química, abrasonados com lixas de granulação de magnitude decrescente (200, 400 e 600) e imersos em tinta Nankin (Acrilex) por 12 horas. A quantidade de poros na área seccionada foi verificada com auxilio da lupa estereoscópica Carl-Zeiss (Alemanha), com aumento de 64 vezes e a área percentual foi calculada utilizando o programa Adobe Photoshop versão 4. O. Os resultados foram submetidos à análise de variância e ao teste de Tukey, em nível de 5% de probabilidade. Os resultados mostraram que: (1) houve aumento da rugosidade superficial em todos os compósitos após o ensaio de escovação, à exceção do Prodigy Condensávet; (2) o Alert@ apresentou maior rugosidade superficial dentre as resinas o Alert@ e Definite@, sem promover efeito nos materiais Z1O0@ e Prodigy Condensável@; estudadas; (3) o selante de superficie diminuiu a rugosidade provocada pela escovação para (4) o melhor método de recuperação da lisura superficial após desgaste abrasivo foi o repolimento, podendo associá-Io à aplicação do selante, especialmente para o Alert@ e (5) a maior porosidade foi obtida para o Alert@, seguido pelo Prodigy Condensável@, quando comparados com o Definite@ e Z100@
Abstract: The aim of this study was to verify the internal porosity, the surface roughness of posterior composite resins submitted on mechanical toothbrushing and the efficency of methods for superficial smoothness recuperation. The materials evaluated were two posterior composite resms: Prodigy Condensable@ (Kerr/Sybron) and Alert@ (Jeneric/Pentron); two universal composite resins: Z100@ (3M) and Definite@ (Degussa) and the surface penetrating sealant Protect-It@ (Jeneric/Pentron). For the measurement of surface rourghness, ten specimens of each material were made at 23 :t 1°C of room temperature and 50 :t 5% of relative humidity, using metallic matrice (2mm in height, 4mm in diameter). After 24 hours, the specimens were polished using Sof-Lex system@ (3M) and one of the surfaces was covered with the surface sealant. AlI the specimens were taken to the rugosimeter (Surfcorder SE 1700) to examine the initial surface roughness, before the mechanical toothbrushing at constant speed of 250 strokes per minute, during 2 hours, totalizing 30.000 cyc1es. The surface roughness was then measured one more time, one of the surfaces was recovered with the surface sealant and this surface was examined again. On the other surface, two more measurements were made, one after the repolishing and other after the surface sealant application. For evaluation of porosity, the specimens were _cut with silicon disc, inc1uded in chemical acrillic resin, abrasioned with sandpapers (200, 400 and 600) and immersed in Nankin corant (Acrilex) for 12 hours. The porosity was quantified in a stereoscopic microscopy Carl-Zeiss (Germany), with 64 x of magnification, and the percentual area was calculated using the Adobe Photoshop 4.0 programo The results were subject to analysis of variance and to Tukey' s test at 5% significant leveI and showed that: (1) the roughness surface increased in all of the materiais after the mechanical toothbrushing, except Prodigy Condensable@; (2) Alert@ showed the most roughness surface; (3) the surface penetrating sea1ant decreased the roughness after the mechanical toothbrushing for Alert@ and Definite@ without any effect for Z1O0@ and Prodigy Condensable@; (4) the best method for superficial smoothness recuperation after abrasion specia11y for the Alert@; (5) Alert@ showed the most porosity, followed by Prodigy was the repolishing, which can be associated with the application of surface sealant, Condensable@, when compared with Definite@ and ZlOO@
Mestrado
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
16

Kim, Duck Young. "Ab initio Lattice Dynamics : Hydrogen-dense and Other Materials." Doctoral thesis, Uppsala universitet, Institutionen för fysik och materialvetenskap, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-9535.

Full text
Abstract:
This thesis presents a theoretical study of materials under high pressure using ab initio lattice dynamics based on density functional theory and density functional perturbation theory using both super-cell and linear response approach. Ab initio lattice dynamics using super-cell approach is applied to compare our theoretical predictions with experimental findings. Phonon dispersion curves of fcc α-γ cerium are calculated and compared with inelastic X-ray scattering data. Pressure dependency of phonon density of states in two cubic phases TiO2 allows us to assign the observed cubic phase in experiments to be of fluorite rather than pyrite structure. Dynamical stability of cotunnite TiO2 phase at low pressure can explain the observed quenching phenomena in experiments. Our calculated O2 vibron mode in both ε-ζ phases of solid oxygen supports the hypothesis that both phases are iso-structural. Hydrogen-dense materials attract great attention not only because they open a path to study phenomena related to metallization (superconductivity) of solid hydrogen but also because they are closely related to important industrial applications (hydrogen storage). Using linear response method, we find that metallic fcc-AlH3 is dynamically stabilized in the range of 72-106 GPa and can persist at ambient pressure if finite temperature effects are considered. For SiH4, we test dynamical stability, Raman spectra, zero point energy, and utilize GW calculations for self energy correction. We find that a metallic tetragonal phase of SiH4 can be assigned to the experimentally observed one. Our ab initio lattice dynamics calculations based on density functional perturbation theory predict that fcc-YH3 is a pressure-induced superconductor with a high transition temperature of 40 K at 17.7 GPa. With increasing pressure this material undergoes a superconductor-metal-superconductor transition and the underlying mechanism of this transition can simultaneously explains also the observed metal-insulator transition at 25 GPa in YH3-δ.
APA, Harvard, Vancouver, ISO, and other styles
17

Borges, Alexandre Luiz Souto [UNESP]. "Avaliação clínica do grau de paralelismo obtido no preparo de planos de guia de dentes suportes de prótese parcial remóvivel, utilizando paralelizador intrabucal." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/132151.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:24:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-04-07. Added 1 bitstream(s) on 2015-12-10T14:30:19Z : No. of bitstreams: 1 000320918.pdf: 858457 bytes, checksum: fe8cfff3b43587e5f4c878675dc48ff8 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O objetivo do presente estudo foi avaliar a eficiência do paralelizador intrabucal ParalAB como método de transferência de planos de guia e a influência do tipo de arcada e posição dos dentes suportes nos preparos realizados por estudantes e profissionais. Foram selecionados 92 modelos de trabalho de pacientes em tratamento na clínica de Prótese Parcial Removível, nos quais foram preparados 321 planos de guia por diferentes operadores utilizando o ParalAB, divididos em dois grupos: grupo 1: profissionais (n=44) e grupo 2: alunos (n=48). Esses grupos foram subdivididos em subgrupos de acordo com a arcada (S - Superior e I - Inferior) e posição (A - Anterior e P - Posterior). A mensuração da inclinação da superfície preparada foi realizada de maneira indireta utilizando um relógio apalpador para registro do deslocamento que proporcionava um cálculo do valor angular em relação à trajetória de inserção escolhida. O valor médio obtido para os grupos 1 e 2 foram respectivamente 0,64 ± 0,36º e 0,77 ± 0,45º, para os subgrupos S e I foram 0,78 ± 0,47º e 0,64 ± 0,34º e para ambos os subgrupos A e P foram 0,71 ± 0,41o. A aplicação do teste estatístico ANOVA (5%), revelou que os efeitos tipo de operador e posição bem como as interações não apresentaram diferença significante já para o tipo de arcada houve diferença significante. Ao se aplicar o teste de Tukey (5%) para o tipo de arcada obteve-se 0,59 ± 0,32o para o grupo 1I, 0,70 ± 0,38o para o 1S, 0,69 ±0,42o para o 2I e 0,78 ± 0,43o para o 2S. Pode-se concluir que o aparelho ParalAB foi capaz de produzir planos de guia com baixo desvio em relação à trajetória de inserção e de restringir a influência da experiência do operador na qualidade do preparo final de planos de guia para os dentes suportes da maxila e que a quantidade de retoques foi muito baixa
The aim of this study was to evaluate the efficiency of the ParalAB intraoral device as a transference method of guide planes and to verify the influence of the arch and position of the abutment teeth on preparations produced by students and dentists. 321 guide planes were prepared by different collaborators using the ParalAB device on 92 casting models deriving from patients of partial removable denture dental clinic. The preparations were divided in two groups: group 1: dentists (n=44) and group 2: students (n=48). These groups were subdivided in subgroups according to the arch (S - maxilla and I - mandible) and position (A - anterior teeth and P - posterior teeth). The inclinations of guide planes were indirectly measured by means of an Order Dial Indicator that provided the angular deviation related to the path of insertion. The mean value obtained for the groups 1 and 2 were respectively 0,64 ± 0,36º and 0,77 ± 0,45º, for the subgroups S and I were 0,78 ± 0,47º and 0,64 ± 0,34º and for both the subgroups A and P were 0,71 ± 0,41o. The ANOVA test (5%) revealed no significant differences for the effects operator and position, as well as their interactions, and for the arch type, there was significant difference. The results of Tukey test (5%) for the type of arch were 0,59 ± 0,32o for the group 1I, 0,70 ± 0,38o for 1S, 0,69 ± 0,42o for 2I and 0,78 ± 0,43o for 2S. It was concluded that the ParalAB device was able to produce guide planes with low deviations related to the path of insertion and to reduce the influence of the professional experience on the quality of preparations made on maxilla and that few new preparations were needed
APA, Harvard, Vancouver, ISO, and other styles
18

Borges, Alexandre Luiz Souto. "Avaliação clínica do grau de paralelismo obtido no preparo de planos de guia de dentes suportes de prótese parcial remóvivel, utilizando paralelizador intrabucal /." São José dos Campos, 2005. http://hdl.handle.net/11449/132151.

Full text
Abstract:
Orientador: José Eduardo Junho de Araújo
Banca: Arlindo Abreu de Castro Filho
Banca: Paulo Sérgio Mutarelli
Banca: Carlos Rocha Gomes Torres
Banca: Eduardo Shigueyuki Uemura
Resumo: O objetivo do presente estudo foi avaliar a eficiência do paralelizador intrabucal ParalAB como método de transferência de planos de guia e a influência do tipo de arcada e posição dos dentes suportes nos preparos realizados por estudantes e profissionais. Foram selecionados 92 modelos de trabalho de pacientes em tratamento na clínica de Prótese Parcial Removível, nos quais foram preparados 321 planos de guia por diferentes operadores utilizando o ParalAB, divididos em dois grupos: grupo 1: profissionais (n=44) e grupo 2: alunos (n=48). Esses grupos foram subdivididos em subgrupos de acordo com a arcada (S - Superior e I - Inferior) e posição (A - Anterior e P - Posterior). A mensuração da inclinação da superfície preparada foi realizada de maneira indireta utilizando um relógio apalpador para registro do deslocamento que proporcionava um cálculo do valor angular em relação à trajetória de inserção escolhida. O valor médio obtido para os grupos 1 e 2 foram respectivamente 0,64 ± 0,36º e 0,77 ± 0,45º, para os subgrupos S e I foram 0,78 ± 0,47º e 0,64 ± 0,34º e para ambos os subgrupos A e P foram 0,71 ± 0,41o. A aplicação do teste estatístico ANOVA (5%), revelou que os efeitos tipo de operador e posição bem como as interações não apresentaram diferença significante já para o tipo de arcada houve diferença significante. Ao se aplicar o teste de Tukey (5%) para o tipo de arcada obteve-se 0,59 ± 0,32o para o grupo 1I, 0,70 ± 0,38o para o 1S, 0,69 ±0,42o para o 2I e 0,78 ± 0,43o para o 2S. Pode-se concluir que o aparelho ParalAB foi capaz de produzir planos de guia com baixo desvio em relação à trajetória de inserção e de restringir a influência da experiência do operador na qualidade do preparo final de planos de guia para os dentes suportes da maxila e que a quantidade de retoques foi muito baixa
Abstract: The aim of this study was to evaluate the efficiency of the ParalAB intraoral device as a transference method of guide planes and to verify the influence of the arch and position of the abutment teeth on preparations produced by students and dentists. 321 guide planes were prepared by different collaborators using the ParalAB device on 92 casting models deriving from patients of partial removable denture dental clinic. The preparations were divided in two groups: group 1: dentists (n=44) and group 2: students (n=48). These groups were subdivided in subgroups according to the arch (S - maxilla and I - mandible) and position (A - anterior teeth and P - posterior teeth). The inclinations of guide planes were indirectly measured by means of an Order Dial Indicator that provided the angular deviation related to the path of insertion. The mean value obtained for the groups 1 and 2 were respectively 0,64 ± 0,36º and 0,77 ± 0,45º, for the subgroups S and I were 0,78 ± 0,47º and 0,64 ± 0,34º and for both the subgroups A and P were 0,71 ± 0,41o. The ANOVA test (5%) revealed no significant differences for the effects operator and position, as well as their interactions, and for the arch type, there was significant difference. The results of Tukey test (5%) for the type of arch were 0,59 ± 0,32o for the group 1I, 0,70 ± 0,38o for 1S, 0,69 ± 0,42o for 2I and 0,78 ± 0,43o for 2S. It was concluded that the ParalAB device was able to produce guide planes with low deviations related to the path of insertion and to reduce the influence of the professional experience on the quality of preparations made on maxilla and that few new preparations were needed
Doutor
APA, Harvard, Vancouver, ISO, and other styles
19

Uemura, Eduardo Shigueyuki [UNESP]. "Estudo comparativo in vitro da resistência ao cisalhamento de discos metálicos de níquel-cromo, com ou sem tratamento de superfície, unidos à dentina bovina com quatro cimentos." Universidade Estadual Paulista (UNESP), 1999. http://hdl.handle.net/11449/114066.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-06-21Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000127814.pdf: 3655431 bytes, checksum: 12e1609540144e91b6188d471f4f987c (MD5)
O estudo foi realizado com oitenta incisivos inferiores bovinos. Os dentes foram extraídos, limpos, as raízes foram seccionadas, o tecido pulpar coronário foi removido e submetido à congelamento a -18°C, por um tempo máximo de 28 dias. A inclusão foi feita em gesso pedra tipo IV. Após o desgaste do esmalte, a dentina superficial foi preparada numa área de 5mm, sendo que a espessura de dentina remanescente foi padronizada (1 ,7 a 2mm). Os discos de liga de Ni-Cr tinham 3X5mm de diâmetro e todos foram submetidos a um ciclo de queima de cerâmica. Metade dos discos foram jateados com óxido de alumínio de 50µm.enquanto a outra metade não sofreu este tratamento. Após limpeza em ultra•som os discos foram cimentados à dentina com: cimento de fosfato de zinco-S.S.White (controle), cimento de ionômero de vidro modificado por resina (CIVMR) Fuji Plus-Fuji, Cimento Resinoso 3M-3M e cimento resinoso Panavia 21-Kuraray. Os dados, após análise estatística ANOVA e teste de Tukey (p< 0,05), mostraram para as variáveis cimento e tratamento de superfície dos discos metálicos os seguintes valores médios de resistência da união dentina/cimento/metal: cimento resinoso Panavia 21 com jateamento (18,29MPa), sem jateamento (17,87MPa); Cimento Resinoso 3M com jateamento (15,81MPa), sem jateamento (11,40MPa); CIVMR com jateamento (16,57MPa), sem jateamento (16,70MPa); cimento de fosfato de zinco com jateamento (3,35MPa), sem jateamento (0,9BMPa). As médias dos valores de resistências ao cisalhamento permitiram concluir: a) houve diferença estatisticamente significante entre o cimento controle e os cimentos em teste; b) não houve diferença estatisticamente significante entre o cimento resinoso Panavia 21 e o CIVMR, mas ambos foram estatisticamente diferentes do cimento resinoso 3M; c) houve diferença estatisticamente significante entre as médias de resistência dos espécimes jateados
This study was carried out with 80 bovine lower incisors. After extraction and debridement the teeth were cut in two parts (crown and roof), having the pulp tissue removed. Crowns were frozen at -18° C for a maximum period of 28 days and then embedded in type IV stone. Preparations were carried out in superficial dentin (minimum 5mm area) while the remaining dentin thickness was standardized (1.7 to 2mm). 80 Ni-Cr disks (3mm height, 5mm diameter) were submitted to a ceramic firing cycle. Half the disks had a 50µm AL2O3 blast while the other half did not. Cements used were: ZPC -SSW, GICRM Fuji Plus-Fuji; 3M resinous cement - 3M; resinous cement Panavia 21- Kuraray. After ANO VA statistical analysis and Tukey's test (p> 0.05), data showed the following shear bond strength mean values at the interface dentin/cement/Ni-Cr disks: dentin/Panavia 21/ blasted Ni-Cr disks (18,29MPa), dentin/Panavia 21/ non blasted Ni-Cr disks (17, 87MPa); dentin/Fuji Plus/blasted Ni-Cr disks (16,57MPa), dentin/Fuji Plus/non-blasted Ni-Cr disks (16.70MPa); dentin/3M resinous cement/blasted Ni-Cr disks (15.81 MPa), dentin/3M resinous cement/non-blasted Ni-Cr disks (11,40MPa); dentin/ZPC/blasted Ni-Cr disks (3,35 MPa), dentin/ZPC/non-blasted Ni-Cr disks (O,98MPa). Results lead to the conclusions: a) control and tested cements mean shear bond strength values showed a significant statistical difference; b) there was no significant statistical difference between Fuji Plus and Panavia mean shear bond strengths, though both values differed statistically from 3M resinous cement mean shear bond strength; c) blasted and non-blasted specimens mean shear bond strength values showed a statistical significant difference; d) There was no significant statistical difference between resin modified GICRM and Panavia 21 mean shear bond strength values, with or without Ni-Cr disks blasting
APA, Harvard, Vancouver, ISO, and other styles
20

Ueda, Julio Katuhide [UNESP]. "Estudo in vitro da resistência à fratura de raízes debilitadas. Efeito de diferentes tratamentos restauradores." Universidade Estadual Paulista (UNESP), 2007. http://hdl.handle.net/11449/101362.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-06Bitstream added on 2014-06-13T19:41:14Z : No. of bitstreams: 1 ueda_jk_dr_arafo.pdf: 3962196 bytes, checksum: a5332fed2f0a6d42be6d3100aaa4ce11 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
A preservação e a restauração de dentes despolpados severamente debilitados é um procedimento complexo e relativamente imprevisível. Este estudo avaliou a resistência à fratura de raízes bovinas experimentalmente debilitadas, reconstruídas internamente com diferentes materiais restauradores em combinação com pinos pré-fabricados de fibra de vidro comparados com raízes íntegras restauradas com núcleo metálico fundido ou pino de fibra de vidro. Foram selecionadas raízes de 120 (n=15) incisivos bovinos inferiores de dimensões semelhantes, dos quais, 90 foram internamente preparados para simular uma raiz debilitada. Todas as raízes foram preenchidas com diferentes materiais restauradores e os espécimes foram submetidos ao teste de resistência ao fracasso/ fratura com a aplicação de uma carga compressiva tangencial a um ângulo de 135º em relação ao longo eixo axial das raízes. Resultados indicaram diferenças estatisticamente significante entre os grupos. As raízes debilitadas restauradas com núcleo metálico fundido (grupo NMF-RD) demonstraram os mais baixos valores de resistência à fratura (107.7436 N), sendo estatisticamente diferentes dos demais grupos. As raízes íntegras restauradas com núcleo metálico fundido (NMF-RI) mostraram os maiores valores de resistência (362.3308 N), mas com diferenças estatisticamente significantes somente quando comparadas às raízes debilitadas restauradas com cimento resinoso dual (Variolink II, Ivoclar Vivadent - grupo Vario-RD), cimento resinoso autopolimerizável (Multilink, Ivoclar Vivadent - grupo Multi-RD) e cimento de ionômero de vidro modificado por resina (Vitremer, 3M ESPE - grupo Vitre-RD) associado com pino de fibra de vidro...
The preservation and restoration of severely weakened pulpless teeth is a difficult and relatively unpredictable procedure. This study evaluated the resistance to fracture of experimentally weakened bovine roots internally reconstructed with different filling materials in combination with prefabricated fiberglass posts compared with restored roots that were relatively intact. The roots of 120 mandibular bovine incisors with similar bulks were selected. Of these, 90 were internally prepared to standardized dimensions, thereby simulating weakness. All roots were filled with different restorative materials. The specimens were submitted to the fracture resistance testing with the application of a tangential compressive loading at an angle of 135º in relation to the long axes of the roots. Results indicated statistically significant differences among the groups. The weakened roots restored with the cast post-core (group NMF-RD) demonstrated the lowest fracture resistance values (107.7436 N), which were significantly different from the averages of the remaining groups. The healthy roots restored with the cast post-core (group NMF-RI) showed the highest values (362.3308 N), but statistically significant differences were observed only when compared with weakened roots restored by the dual-cured resin cements (Variolink II, Ivoclar Vivadent - group Vario-RD), chemically cured resin cements (Multilink, Ivoclar Vivadent - group Multi-RD) and resin-modified glass-ionomer cement (Vitremer, 3M ESPE - group Vitre-RD) associated with fiberglass posts. There was not statistically significant differences among the groups of the weakened roots restored with self-adhesive universal resin cement (RelyX Unicem, 3M ESPE - group Unicem-RD), composite resin (Tetric 15 Ceram, Ivoclar Vivadent - group Tetric-RD), group Vitre-RD and group Vario-RD... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
21

Renouf, Mathieu. "Optimisation numérique et calcul parallèle pour l'étude de milieux divisés bi- et tridimensionnels." Phd thesis, Université Montpellier II - Sciences et Techniques du Languedoc, 2004. http://tel.archives-ouvertes.fr/tel-00007686.

Full text
Abstract:
Ce travail est dédié à la simulation numérique des milieux granulaires denses dont les interaction sont régies par des lois de contact frottant. L'approche utilisée est la méthode "Non Smooth Contact Dynamics" qui traite le contact sans régularisation numérique et utilise un algorithme de type Gauss-Seidel. Pour diminuer le temps nécessaire aux simulations, et mener des études paramétriques fines, nous avons procédé à plusieurs types d'optimisation numérique portant, dans un premier temps, sur la mise en oeuvre de différents types d'implémentation exploitant ou non le calcul parallèle (optimisation informatique) puis, dans un second temps, sur le développement d'un algorithme de type Gradient Conjugué (optimisation algorithmique). Ces différentes stratégies se révèlent très efficaces nous permettant de simuler plus rapidement des problèmes bi et tridimensionnels. Deux applications pointant sur la diversité de comportement des milieux granulaires (liquide/solide) ont été abordées: une étude numérique sur les écoulements en tambour tournant venant compléter des résultats expérimentaux et une étude de mouvements tectoniques par éléments discrets permettant de porter un nouveau regard sur les expériences analogiques en "boîtes à sable" effectuées en géophysique.
APA, Harvard, Vancouver, ISO, and other styles
22

Melo, Filho Antonio Braulino de. "Estudo comparativo in vitro da resistência à remoção de grampos circunferenciais aplicados sobre dentes íntegros e restaurados com resina composta /." São José dos Campos, 1994. http://hdl.handle.net/11449/131989.

Full text
Abstract:
Orientador: João Vieira de Moraes
Banca: José Eduardo Junho de Araújo
Banca: Rogério Lacaz Netto
A BFO possui a versão preliminar da tese, com alterações, sob o título: Estudo comparativo in vitro do comportamento, quanto à força necessária à remoção, de grampos circunferenciais de Prótese Parcial Removível com regimes de trabalho sobre esmalte e sobre um tipo de resina composta.
Resumo : Foi realizado um estudo experimental in vitro para investigar o comportamento da força necessária para o deslocamento de grampos circunferenciais de P.P.R. em dois grupos de corpos de prova: 1 com regime de trabalho do terminal retentivo sobre esmalte 2 com regime de trabalho do terminal retentivo sobre resina composta Para tal finalidade foi idealizado um dispositivo, construído a partir de uma máquina de costura de marca Elgin que tinha por objetivo simular repetidamente o movimento de introdução e remoção de grampos circunferenciais sobre os corpos de prova. O dispositivo contava ainda com uma plataforma para fixar os corpos de prova e permitir aferições, um contador de ciclos e um dinamometro. Os corpos de prova foram obtidos a partir da inclusão em gesso de dentes naturais extraídos, íntegros, do grupo dos molares, cujas áreas retentivas eram em esmalte natural ou construídas artificialmente, por adição de resina composta. Os grampos foram obtidos a partir de esculturas com resina acrílica e cera e fundidos em liga de cobalto cromo. A resina composta usada foi de última geração, do tipo monomodal, fotopolimerizável e retida no esmalte através de ataque ácido. Os testes foram realizados em meio aquoso, estabelecendo-se para cada corpo de prova cinco mil ciclos. Foram feitas verificações a cada cem ciclos até dois mil e a cada duzentos ciclos até o total de cinco mil. Os resultados mostraram que as variações na quantidade de força necessária para remover os grampos dos corpos de prova durante todo o período dos ensaios foi desprezível, sem significância, tanto para aqueles com áreas retentivas em esmalte como naqueles com áreas retentívas artificialmente feitas com resina composta
Abstract: An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin
Mestre
APA, Harvard, Vancouver, ISO, and other styles
23

Joaquim, Natália Martins 1989. "Análise da citotoxicidade de materiais obturadores de dentes decíduos." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288856.

Full text
Abstract:
Orientador: Fernanda Miori Pascon
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-26T01:46:29Z (GMT). No. of bitstreams: 1 Joaquim_NataliaMartins_M.pdf: 1245977 bytes, checksum: c5a3811c7ba1d723505963537d831210 (MD5) Previous issue date: 2014
Resumo: Endodontia em dentes decíduos é um procedimento de suma importância para manter a integridade e saúde dos dentes e tecidos de suporte. Sendo assim, o uso de materiais obturadores de canais radiculares que apresente o máximo de propriedades desejáveis é indispensável. O objetivo do presente estudo foi analisar a citotoxicidade de diferentes materiais obturadores em fibroblastos do ligamento periodontal humano (PDL) e em células osteoblásticas de osteossarcoma humano (Saos-2). Os fibroblastos foram cultivados em meio de cultura (meio Eagle modificado por Dulbeco - DMEM) suplementado com 1% soro fetal bovino (FBS) e antibióticos. Os osteoblastos foram cultivados em meio de cultura McCoy¿s suplementado com 15% FBS e antibióticos. Próximos de atingir a confluência, as células foram plaqueadas na concentração de 7x103 células por poço e foram expostas aos seguintes materiais, conforme os grupos: G1- Meio de cultura sem material obturador (controle negativo), G2- Dimetiilsulfóxido (DMSO) (controle positivo), G3- Calen®, G4- Calen® associada ao Óxido de Zinco, G5- Calen® associada ao Iodofórmio, G6- Óxido de zinco e eugenol (OZE), G7- Vitapex® e G8- UltraCal®XS. A manipulação dos materiais foi realizada em condições assépticas. A citotoxicidade dos materiais obturadores foi analisada em intervalos de tempos (8, 24 e 48 horas) pelo método de redução MTS e classificado como não citotóxico, citotoxicidade leve, moderada e grave. O grupo controle negativo foi composto apenas por células, sem o uso de material obturador. A análise morfológica das células foi realizada por meio da microscopia de fluorescência. Os dados obtidos foram submetidos à análise de variância dois fatores e ao teste Tukey para comparação entre os grupos, com nível de significância 5%. As imagens obtidas por meio da microscopia de fluorescência foram analisadas de forma descritiva. Os resultados mostraram que para os fibroblastos, Calen®(85,91±10,01), Calen® associada ao Óxido de Zinco (85,91±8,16) e Calen® associada ao Iodofórmio (83,96±13,95) diferiram do controle negativo (100±0) e positivo (19.72±5,70) após 8 horas de exposição. Para os osteoblastos, Calen® associada ao Óxido de Zinco (75,87±19,16), Calen® associada ao Iodofórmio (75,5±12,40) e o OZE (68,71±22,19) foram os únicos grupos que em 8 horas diferiram do controle negativo (100±0) e positivo (22,18±6,77). Pode-se concluir que todos os materiais avaliados, para fibroblastos do ligamento periodontal humano, não foram citotóxicos ao longo do tempo. No entanto, Calen® associada ao Iodofórmio apresentou toxicidade leve em 48 horas para os osteoblastos. Vitapex® foi o material que apresentou menor toxicidade celular nos osteoblastos em 8 e 48 horas, comparando-se os outros materiais avaliados. Calen® associado ao Óxido de zinco, Calen® associado ao Iodofórmio e OZE foram capazes de modificar a morfologia dos fibroblastos, mas para os osteoblastos não foram observadas alterações morfológicas
Abstract: Endodontics in primary teeth is an important procedure to maintain the integrity and health of the teeth and supporting tissues. Using a root canal filling material that shows desirable properties is indispensable. The aim of the present study was to evaluate the root filling materials cytotoxicity on periodontal ligament fibroblasts (PDL) and osteoblastic human osteosarcoma cells (Saos-2). Fibroblasts were cultured in culture medium (Dulbeco modified Eagle medium - DMEM) supplemented with 1% fetal bovine serum (FBS) and antibiotics. The osteoblasts were cultured in McCoy's culture medium supplemented with 15% FBS and antibiotics. Next to reach confluence, the cells were plated at a concentration of 7x103 cells per well and were exposed to materials, according to the groups: G1 - culture medium without filling material (negative control); G2- Dimethyl sulfoxide (DMSO) (positive control); G3 ¿ Calen®; G4 - Calen® associated with Zinc Oxide; G5 - Calen® associated with Iodoform; G6 ¿ Zinc Oxide and eugenol (ZOE); G7 - Vitapex®; G8 - UltraCal® XS. The materials were prepared under aseptic conditions. Cytotoxicity was evaluated by cell viability at time intervals (8, 24 and 48 h) by MTS assay and rated as non-cytotoxic, mild, moderate and severe cytotoxicity. The negative control group was composed only of cells without the use of filling material. Cells morphological were observed by fluorescence microscopy. Data were submitted to two-way analysis of variance with post-hoc comparisons base on Tukey's multiple comparisons, with the significance level fixed at 5%. The images obtained at fluorescence microscopy were evaluated using descriptive analysis. The results showed that for fibroblasts, Calen®(85.91±10.01), Calen® associated with Zinc Oxide (85.91±8.16) e Calen® associated with Iodoform (83.96±13.95) was differ from the negative control (100±0) and positive (19.72±5.70), at 8 h. For osteoblasts, Calen® associated with Zinc Oxide (75.87±19.16), Calen® associated with Iodoform (75.5±12.40) and ZOE (68.71±22.19) differed from negative control (100±0) and positive (22.18±6.77) in 8 h. It can be concluded that all materials were non- cytotoxic to human fibroblasts cells over time. However, Calen® + Iodoform showed higher cytotoxicity to osteoblasts at 48 h. Vitapex® was the material that showed the less cell cytotoxicity in osteoblasts at 8 and 48 h, compared to the other materials tested. Calen® associated with Zinc Oxide, Calen® associated with Iodoform and ZOE was able to modify the morphology of fibroblasts, but osteoblasts but no morphologic alterations were observed
Mestrado
Odontopediatria
Mestra em Odontologia
APA, Harvard, Vancouver, ISO, and other styles
24

Lopes, Rafael Paiva. "Avaliação da permeabilidade dentária de dentes submetidos à reintervenção endodôntica quando obturados com diferentes cimentos." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/23/23145/tde-16012012-143744/.

Full text
Abstract:
O presente estudo avaliou ex vivo a permeabilidade das paredes dentinárias de canais radiculares, após a remoção de três diferentes associações de materiais obturadores. Para tanto, 36 pré-molares uni-radiculares extraídos, com comprimento e aspectos anatômicos semelhantes, tiveram a cirurgia de acesso à câmara pulpar realizada, preparo do canal radicular até instrumentos ProTaper F4 e obturação com uma das seguintes associações de materiais: G1 - guta-percha e cimento Fill Canal (n=10); G2 - guta-percha e cimento AH-Plus (n=10); G3 - Resilon e cimento Epiphany (n=10). Seis espécimes tiveram seus canais preparados mas não foram obturados para fins de controle positivo. Após 24 horas em estufa, os canais foram desobturados, com instrumentos rotatórios NRT para retratamento, limas do tipo K #40 e solvente de óleo de casca de laranja. Terminada a desobturação, os espécimes foram impermeabilizados e submetidos ao teste de impregnação de azul de metileno 1% por 24 horas. Os dentes foram então lavados em água corrente por 24 horas, tiveram sua coroas amputadas e as raízes seccionadas horizontalmente em fatias de 1mm. Uma secção de cada terço radicular foi selecionada e fotografada, e o percentual de dentina corada em cada secção foi calculada por meio de um software de análise gráfica. Os resultados demonstraram diferença significativa entre os grupos experimentais e o grupo controle (p<0,05), contudo, não houve diferença estatística entre os grupos experimentais (p>0,05). Concluiu-se assim que o tipo de material obturador utilizado não influencia na permeabilidade dentinária após sua remoção.
The purpose of this study was to evaluate ex vivo the permeability of root canal dentin walls after the removal of three different combinations of filling materials. To this end, 36 extracted human single-rooted premolars, with similar length and anatomy, had surgery access to the pulp chamber, root canal preparation was performed to F4 ProTaper instruments and filling with one of the following associations of filling materials: G1 - gutta-percha and Fill Canal cement (n = 10); G2 - gutta-percha and AH Plus cement (n = 10); G3 - Resilon cones and Epiphany cement (n = 10). Six specimens were prepared but its canals were not filled for positive control. After 24 hours at 37 ° C, the canals were desobturated, making use of NRT rotary instruments , # 40 K-type files and orange oil based solvent. After the removal of the filling material, specimens were sealed and tested for impregnation of dye in 1% methylene blue for 24 hours in the absence of vacuum. The teeth were then washed in running water for 24 hours, had their crowns amputated and the roots sectioned horizontally into 1 mm slices. For each root third , one section was selected and photographed, the images were stored on computer and the percentage of stained dentin in each section was calculated using a graphical analysis software. The results showed a statistically significant difference between experimental groups and control group (p <0.05). However, there was no statistical difference between experimental groups (p> 0.05). Thus, it was concluded that the type of filling material does not influence dentin permeability after its removal.
APA, Harvard, Vancouver, ISO, and other styles
25

Araújo, Sandra Maria Santos de Oliveira 1954. "Obtenção e caracterização de corpos densos e porosos de campósitos de alumina e zircônia para utilização como biomaterial." [s.n.], 2012. http://repositorio.unicamp.br/jspui/handle/REPOSIP/263580.

Full text
Abstract:
Orientador: Cecília Amélia de Carvalho Zavaglia
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica
Made available in DSpace on 2018-08-20T17:09:57Z (GMT). No. of bitstreams: 1 Araujo_SandraMariaSantosdeOliveira_D.pdf: 2193089 bytes, checksum: e02431a815e7c5e9923283bd405849a9 (MD5) Previous issue date: 2012
Resumo: Nesta tese foram investigadas as propriedades físicas, mecânicas e microestruturais de compósitos cerâmicos densos e porosos de Al2O3-ZrO2 cujas matérias primas foram previamente moídas em moinho vibratório com a finalidade de se obter nanocompósitos com melhores propriedades que as cerâmicas de alumina e de zircônia puras, e compósitos microestruturados. A finalidade desses estudos foi desenvolver um processamento de matérias primas para aplicações biomédicas futuras, como por exemplo: cabeça de fêmur e acetábulo cerâmicos, para implantes coxofemorais, pilares cerâmicos, para implantes dentais e braquetes cerâmicos, usados em ortodontia. As matérias primas, Al2O3 e ZrO2-3%Y2O3 foram caracterizadas quanto à composição e suas estruturas cristalinas. Foram cominuídas em moinho vibratório desenvolvido na Escola de Engenharia de São Carlos-USP, por 2, 4, 6 e 10 horas. Os pós resultantes da moagem por seis horas foram misturados e homogeneizados em três proporções, 15, 30 e 45 % de zircônia em alumina por 22 horas. O corpo denso foi conformados convencionalmente, por prensagem uniaxial (50MPa), prensagem isostática (200MPa) e sinterização em 1450°C por 2 horas. Por seu conjunto de características mecânicas a composição com 30% de zircônia e 70% de alumina foi usada para produção do corpo poroso, características estas superiores tanto às do compósito nanoestruturado como às do corpo monolítico e compatíveis à aplicação estrutural. O corpo poroso foi obtido pelo método da esponja, sinterizado em 1600°C e apresentou resistência à compressão de 6,71 MPa, valor que está contido na faixa de resistência do osso esponjoso para uma porosidade acima de 60%, poros interconectados e de tamanho compatíveis aos exigidos pela engenharia tecidual. O teste de citotoxicidade confirmou a biocompatibilidade do compósito poroso. A biocompatibilidade associada ao valor da resistência mecânica à compressão e ao tamanho dos poros permite afirmar a potencialidade do compósito obtido nas condições do trabalho como material a ser testado para crescimento de células
Abstract: In this thesis it was investigated the mechanical properties of a Al2O3-ZrO2 ceramic composite which raw materials were previously ground on a vibratory mill in order to obtain a micro structured nanocomposite with better properties than pure alumina and zirconium. The purpose of this paper was to develop raw materials for future biomedical applications, as: femoral head and ceramic acetabulum, for hip implants, ceramic abutments, for dental implants and ceramics brackets, used in orthodontics. The raw materials, Al2O3 e ZrO2-3%Y2O3 were characterized as to composition and crystal structures. They were comminuted in a vibratory mill designed by Escola de Engenharia-USP/ São Carlos, for 2, 4, 6 e 10 hours. The 6-hours milling post-derived were mixed and homogenized in three ratios, 15, 30 e 45 % of zirconium in alumina for 22 hours. The dense body was conventionally shaped, by single axial pressing (50MPa), isostatic pressing (200MPa) and sintering in 1450°C for 2 hours. Due the set of mechanical characteristic, compositions 30%-zirconium and 70%-alumina was used to produce the porous body production and supported for structural applications. The porous specimen was obtained by the sponge method sintered at 1600ºC showed a compressive strength of 6,71 MPa, a value which is in the resistance in the range of cancellous bone resistance, for a porosity above 60%, interconnected pores and size compatible with those required by tissue engineering. Citotoxicity test confirmed the composite biocompatibility. Biocompatibility associated with mechanical strength and pores size allows to affirm the potential of the composite obtained in those conditions as a material to be tested for cell growth
Doutorado
Materiais e Processos de Fabricação
Doutora em Engenharia Mecânica
APA, Harvard, Vancouver, ISO, and other styles
26

Melo, Filho Antonio Braulino de [UNESP]. "Estudo comparativo in vitro da resistência à remoção de grampos circunferenciais aplicados sobre dentes íntegros e restaurados com resina composta." Universidade Estadual Paulista (UNESP), 1994. http://hdl.handle.net/11449/131989.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:22:56Z (GMT). No. of bitstreams: 0 Previous issue date: 1994-06-30. Added 1 bitstream(s) on 2015-12-10T14:29:10Z : No. of bitstreams: 1 000026434.pdf: 4352939 bytes, checksum: f59dc1edfd8a91ab4f0abc5ee063d699 (MD5)
Foi realizado um estudo experimental in vitro para investigar o comportamento da força necessária para o deslocamento de grampos circunferenciais de P.P.R. em dois grupos de corpos de prova: 1 com regime de trabalho do terminal retentivo sobre esmalte 2 com regime de trabalho do terminal retentivo sobre resina composta Para tal finalidade foi idealizado um dispositivo, construído a partir de uma máquina de costura de marca Elgin que tinha por objetivo simular repetidamente o movimento de introdução e remoção de grampos circunferenciais sobre os corpos de prova. O dispositivo contava ainda com uma plataforma para fixar os corpos de prova e permitir aferições, um contador de ciclos e um dinamometro. Os corpos de prova foram obtidos a partir da inclusão em gesso de dentes naturais extraídos, íntegros, do grupo dos molares, cujas áreas retentivas eram em esmalte natural ou construídas artificialmente, por adição de resina composta. Os grampos foram obtidos a partir de esculturas com resina acrílica e cera e fundidos em liga de cobalto cromo. A resina composta usada foi de última geração, do tipo monomodal, fotopolimerizável e retida no esmalte através de ataque ácido. Os testes foram realizados em meio aquoso, estabelecendo-se para cada corpo de prova cinco mil ciclos. Foram feitas verificações a cada cem ciclos até dois mil e a cada duzentos ciclos até o total de cinco mil. Os resultados mostraram que as variações na quantidade de força necessária para remover os grampos dos corpos de prova durante todo o período dos ensaios foi desprezível, sem significância, tanto para aqueles com áreas retentivas em esmalte como naqueles com áreas retentívas artificialmente feitas com resina composta
An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin
APA, Harvard, Vancouver, ISO, and other styles
27

Berger, Sandrine Bittencourt. "Efeitos de agentes clareadores de alta concentração para tratamento em consultorio na microdureza, morfologia e composição quimica do esmalte humano." [s.n.], 2007. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287820.

Full text
Abstract:
Orientador: Marcelo Giannini
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-08T05:38:41Z (GMT). No. of bitstreams: 1 Berger_SandrineBittencourt_M.pdf: 5356625 bytes, checksum: 1b4907c704681cbb071f3574823129e2 (MD5) Previous issue date: 2007
Resumo: Vários estudos têm se preocupado com os efeitos adversos produzidos pelos agentes clareadores de uso caseiro e de consultório. Este estudo tem como objetivo avaliar os efeitos de agentes clareadores de alta concentração (peróxido de hidrogênio a 35%) utilizados em consultório na dureza, composição química e estrutural do esmalte humano. Sessenta e cinco terceiros molares humanos hígidos foram utilizados. Dois fragmentos de esmalte (4x4x3mm) foram removidos das faces vestibular e lingual de cada dente. As amostras foram divididas em 10 grupos (n=10). Antes do clareamento, foram polidas e submetidas ao teste de microdureza Knoop (KHN) e análise em Espectroscopia Raman Transformada de Fourier (ERTF) para determinação da relação de fosfato (PO4) e carbonato (CO3) presente no esmalte não tratado. O grupo controle (GC) não foi submetido ao tratamento clareador. Nos grupos experimentais foram utilizados três diferentes agentes clareadores (Whiteness HP Maxx - W; Pola Office ¿ P e Opalescence Xtra - O) bem como três formas de irradiação (sem irradiação - SI; irradiação com lâmpada halógena ¿ LH, irradiação com LED + Laser Diodo - L). Após os tratamentos, os géis clareadores foram coletados com a solução de enxágüe para avaliação da concentração de cálcio, utilizando espectrofometria de absorção atômica. Em seguida, as amostras foram submetidas à ERTF, ao teste de microdureza superficial e interna, observadas em microscopia eletrônica de varredura para analisar as alterações na superfície e avaliadas em microscopia de luz polarizada para analisar os efeitos das técnicas de clareamento na desmineralização superficial do esmalte. As médias de microdureza superficial variaram de 297,48±16,29 (O-SI) a 317,86±9,62 (P-L) antes do tratamento clareador e 260,94±17,17 (OSI) a 291,68±16,20 (W-LH, pós-clareamento). Para a microdureza interna as médias variaram de 69,55±42,02 (O-L, 20ìm) a 288,13±53,16 (GC, 80ìm). Na determinação da composição química do esmalte através de ERTF, para o fosfato a média da área do pico de fosfato variou entre 14,50± 0,32 (O-SI) a 14,90 ± 0,28 (P-LH) antes do tratamento, sendo que após o tratamento variaram entre 14,24 ± 0,72 (P-L) a 15,03 ± 0,23 (P-LH). Para o carbonato valores de: 3,60 ± 0,52 (W-LH) a 4,41 ± 0,67 (P-SI) antes do tratamento foram encontrados. Após o tratamento variaram entre: 3,69 ± 0,29 (GC) a 4,41 ± 0,13 (P-LH). A concentração de cálcio presente na solução de enxágüe variou entre 0,32 (W-SI) a 1,61 (O-L). Na microscopia eletrônica de varredura, com exceção do grupo controle, todos os grupos apresentaram alterações morfológicas na superfície. Em microscopia de luz polarizada, os grupos Whiteness sem irradiação, com luz halógena e LED/laser, Pola Office com LED/laser e Opalescence com luz halógena e LED/laser apresentaram desmineralização em profundidade. Observamos alterações no conteúdo mineral pela diminuição significativa dos valores de microdureza, perda de cálcio e desmineralização visualizada em microscopia de luz polarizada, além de alterações morfológicas na superfície do esmalte visualizadas em microscopia eletrônica de varredura. Concluímos que a utilização do peróxido de hidrogênio a 35% empregado no tratamento clareador em consultório requer cautela uma vez que, causa alterações na estrutura do esmalte como mostrado no presente estudo
Abstract: Several studies have been concerned with the adverse effects produced by home applied and in-office bleaching treatments. The aim of this study is to evaluate the effects of highconcentrated bleaching agents (35% hydrogen peroxide) on human enamel microhardness, chemical and structural composition. Sixty and five human third molars human were used. Two enamel blocks (4x4x3mm) were obtained from bucal and lingual surfaces of each tooth. The samples were divided in 10 groups (n=10). Before the bleaching treatment, samples were polished and submitted to microhardness test (Knoop) and Fourier Transform Raman Spectroscopy (FTRS) analysis in order to determine the concentration of phosphate (PO4) and carbonate (CO3) present the enamel. Control group (CG) was not submitted to the bleaching treatment. In the remaining experimental groups three different bleaching agents were used (Whiteness HP Maxx - W; Pola Office ¿ P and Opalescence Xtra - O) and three ways of irradiation (no light irradiation - N; irradiation with halogen light - HL and irradiation with LED + Diode Laser - L). After the treatments, the rinsing water solution was to evaluate the concentration of calcium, by means of atomic absorption spectrometry analysis. Afterwards, the samples were re-submitted to FTRS and to surface and cross-sectional microhardness measurement. Samples were observed in scanning electron microscopy to observe surface alterations and in polarized light microscopy to examine the effects of the bleaching techniques in the demineralization of the enamel. The average surface microhardness values microhardness ranged from 297.48±16.29 (O-N) to 317.86±9.62 (P-L) before the bleaching treatment and 260.94±17.17 (O-N) to 291.68±16.20 (W-HL) after bleaching. The mean values obtained after cross-sectional microhardness measurement ranged from 69.55±42.02 (O-L, 20µm) to 288.13±53.16 (CG, 80 µm). The phosphate concentration on enamel determined by means of FTRS ranged from 14.50±0.32 (O-N) to 14.90±0.28 (P-HL) before the treatment. After the treatment the phosphate concentration ranged from 14.24±0.72 (P-L) to 15.03±0.23 (P-HL). The concentration of carbonate present on treated enamel ranged from 3.60±0.52 (WHL) to 4.41±0.67 (P-N) before the treatment and after the treatment, the concentration varied from 3.69±0.29 (CG) to 4.41±0.13 (P-LH). The concentration of calcium in the rinsing water solution ranged from 0.32 (W-N) to 1.61 (O-L). The scanning electron microscopy showed that all groups presented morphologic alterations in the surface, except for the control group. The images obtained after polarized light microscopy showed that Whiteness without irradiation, with halogen light and LED/diode laser, Pola Office with LED/diode laser and Opalescence with halogen light and LED/diode laser presented demineralization. Alterations on enamel mineral content, significant decrease of enamel microhardness and calcium concentration, demineralization observed by means of polarized light microscopy and morphological alterations on enamel observed by means of scanning electron microscopy were observed in the present study. In conclusion, the use of the 35% hydrogen peroxide as a bleaching agent in clinical situations requires caution, since it may cause alterations on enamel structure as observed in the present study
Mestrado
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
28

Ramos, Carolina Júdica [UNESP]. "Comportamento do esmalte de dentes decíduos após desafio desmineralizante em função de materiais restauradores: estudo ao microscópio de luz polarizada." Universidade Estadual Paulista (UNESP), 2003. http://hdl.handle.net/11449/131934.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:22:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-08-08. Added 1 bitstream(s) on 2015-12-10T14:28:49Z : No. of bitstreams: 1 000209033.pdf: 3006947 bytes, checksum: e0f461b5643caabba97c18e5683c7dda (MD5)
O objetivo deste estudo in vitro foi analisar ao microscópio de luz polarizada o comportamento do esmalte decíduo adjacente a quatro materiais restauradores, após um desafio desmineralizante. Foram realizados preparos cavitários de Classe V nas faces vestibulares de quarenta molares decíduos hígidos, os quais foram aleatoriamente divididos em quatro grupos experimentais (n=10) de acordo com os seguintes materiais: uma resina composta modificada por poliácidos (Dyract AP), uma resina composta híbrida (Z-250), um cimento de ionômero de vidro modificado por resina (Vitremer) e um cimento de ionômero de vidro convencional (Fuji IX GP Fast). Após o polimento das restaurações, os espécimes foram impermeabilizados e submetidos a um desafio desmineralizante representado pela imersão dos espécimes em gelatina acidificada (pH4,5) em temperatura ambiente por 14 dias. Após este período, os espécimes foram incluídos em resina e seccionados longitudinalmente obtendo-se secções de 100µm de espessura, que foram embebidas em água destilada para análise ao microscópio de luz polarizada. Os resultados obtidos revelaram formação de lesões artificiais de cárie em todos os grupos e os valores de profundidade da lesão externa, obtidos por meio de análise histomorfométrica, foram submetidos aos testes estatísticos de Kruskal-Wallis e Dunn (5%) constatando-se que o grupo do cimento de ionômero de vidro exibiu profundidade da lesão externa significantemente menor do que o grupo restaurado com resina composta. Concluiu-se que a desmineralização do esmalte decíduo pode ser influenciada pelo uso de diferentes materiais restauradores
The aim of this in vitro study was to evaluate by polarized light microscopy the development of artificial carious lesions in primary teeth adjacent to different restorative materials. Buccal class V restorations were prepared in 40 deciduous human molars with margins in enamel which were ramdonly divided into four groups (n=10): a poliacid modified resin composite (Dyract AP); a hybrid resin composite (Z-250); a resin-modified glass ionomer cement (Vitremer) and a conventional glass ionomer cement (Fuji IX GP Fast). After the restorative procedures, all teeth surfaces were coated with nail polish, except for the restoration area and 1 mm rim of tooth structure. ln order to induce artificial carious lesions, the specimens were immersed into an acidified gel (pH 4,5) for 14 days at room temperature. After this, the specimens were prepared for polarized light microscopy in an imbibition's media of water. The results showed the development of caries lesions in all groups. The data was analysed by Kruskal-Wallis and Dunn's test (5%) and the specimens restored with glass ionomer cement exhibited- the depth of caries significantly lower than the group restored with composite resin. lt was concluded that the restorative material can influence the demineralization of primary enamel
APA, Harvard, Vancouver, ISO, and other styles
29

Ramos, Carolina Júdica. "Comportamento do esmalte de dentes decíduos após desafio desmineralizante em função de materiais restauradores : estudo ao microscópio de luz polarizada /." São José dos Campos, 2003. http://hdl.handle.net/11449/131934.

Full text
Abstract:
Orientador: Silvio Issáo Myaki
Banca: Maria Naira Pereira Friggi
Banca: Yasmin Rodarte Carvalho
Resumo: O objetivo deste estudo in vitro foi analisar ao microscópio de luz polarizada o comportamento do esmalte decíduo adjacente a quatro materiais restauradores, após um desafio desmineralizante. Foram realizados preparos cavitários de Classe V nas faces vestibulares de quarenta molares decíduos hígidos, os quais foram aleatoriamente divididos em quatro grupos experimentais (n=10) de acordo com os seguintes materiais: uma resina composta modificada por poliácidos (Dyract AP), uma resina composta híbrida (Z-250), um cimento de ionômero de vidro modificado por resina (Vitremer) e um cimento de ionômero de vidro convencional (Fuji IX GP Fast). Após o polimento das restaurações, os espécimes foram impermeabilizados e submetidos a um desafio desmineralizante representado pela imersão dos espécimes em gelatina acidificada (pH4,5) em temperatura ambiente por 14 dias. Após este período, os espécimes foram incluídos em resina e seccionados longitudinalmente obtendo-se secções de 100µm de espessura, que foram embebidas em água destilada para análise ao microscópio de luz polarizada. Os resultados obtidos revelaram formação de lesões artificiais de cárie em todos os grupos e os valores de profundidade da lesão externa, obtidos por meio de análise histomorfométrica, foram submetidos aos testes estatísticos de Kruskal-Wallis e Dunn (5%) constatando-se que o grupo do cimento de ionômero de vidro exibiu profundidade da lesão externa significantemente menor do que o grupo restaurado com resina composta. Concluiu-se que a desmineralização do esmalte decíduo pode ser influenciada pelo uso de diferentes materiais restauradores
Abstract: The aim of this in vitro study was to evaluate by polarized light microscopy the development of artificial carious lesions in primary teeth adjacent to different restorative materials. Buccal class V restorations were prepared in 40 deciduous human molars with margins in enamel which were ramdonly divided into four groups (n=10): a poliacid modified resin composite (Dyract AP); a hybrid resin composite (Z-250); a resin-modified glass ionomer cement (Vitremer) and a conventional glass ionomer cement (Fuji IX GP Fast). After the restorative procedures, all teeth surfaces were coated with nail polish, except for the restoration area and 1 mm rim of tooth structure. ln order to induce artificial carious lesions, the specimens were immersed into an acidified gel (pH 4,5) for 14 days at room temperature. After this, the specimens were prepared for polarized light microscopy in an imbibition's media of water. The results showed the development of caries lesions in all groups. The data was analysed by Kruskal-Wallis and Dunn's test (5%) and the specimens restored with glass ionomer cement exhibited- the depth of caries significantly lower than the group restored with composite resin. lt was concluded that the restorative material can influence the demineralization of primary enamel
Mestre
APA, Harvard, Vancouver, ISO, and other styles
30

Amaral, Thais Helena Andreolli do. "Materiais para cimentação de restaurações protéticas: resposta no tecido subcutâneo de camundongos isogênicos e na polpa de dentes de cães." Universidade de São Paulo, 2007. http://www.teses.usp.br/teses/disponiveis/58/58135/tde-13112007-115519/.

Full text
Abstract:
O objetivo desse trabalho foi avaliar a biocompatibilidade de diferentes agentes cimentantes (Ketac Cem Easy Mix 3M ESPE e RelyX Unicem 3M ESPE) microscopicamente, por meio de implantes em tecido conjuntivo subcutâneo de camundongos isogênicos; microscópica e radiograficamente, após aplicação em cavidades profundas, próximas à polpa, em dentes de cães. No estudo em tecido conjuntivo subcutâneo foram utilizados quarenta camundongos isogênicos da linhagem BALB/c divididos em 9 grupos com 3 períodos experimentais: Grupo I: Ketac Cem Easy Mix (7 dias), Grupo II: RelyX Unicem (7 dias), Grupo III: tubo de polietileno vazio (7 dias), Grupo IV: Ketac Cem Easy Mix (21 dias) Grupo V: RelyX Unicem (21 dias), Grupo VI: tubo de polietileno vazio (21 dias), Grupo VII: Ketac Cem Easy Mix (63 dias), Grupo VIII: RelyX Unicem (63 dias), Grupo IX: tubo de polietileno vazio (63 dias). No estudo em dentes de cães foram utilizados quarenta dentes (80 raízes) de 4 cães, distribuídos em 6 grupos: Grupo I: Ketac Cem Easy Mix (7 dias), Grupo II: RelyX Unicem (7 dias), Grupo III: Cimento de óxido de zinco e eugenol (7 dias), Grupo IV: Ketac Cem Easy Mix (70 dias) Grupo V: RelyX Unicem (70 dias), Grupo VI: Cimento de óxido de zinco e eugenol (70 dias). A análise microscópica no tecido conjuntivo subcutâneo foi realizada em microscópio de luz comum, baseada nos seguintes parâmetros: infiltrado inflamatório (celularidade e tipo de célula) e reparo tecidual. Na análise microscópica em dentes de cães, foi registrada a descrição completa das características da dentina, polpa e tecidos periapicais de acordo com os seguintes aspectos: Presença de polpa normal; Presença de dentina reacional; Presença de ulceração; Pulpite e Presença de necrose pulpar, sendo os resultados submetidos à análise estatística utilizando-se o teste exato de Fisher (p<0,05). A avaliação radiográfica foi realizada por meio de radiografias periapicais obtidas previamente à execução dos atos operatórios e após os períodos experimentais, com relação à integridade da lâmina dura, presença ou ausência de reabsorções radiculares e áreas de rarefação óssea periapical. Os resultados da análise microscópica evidenciaram que, quando empregados sobre a dentina, ambos os cimentos não ocasionaram reações pulpares insatisfatórias. No entanto, quando colocados diretamente sobre o tecido pulpar, desencadearam reação inflamatória intensa, com necrose pulpar e desenvolvimento de reação periapical. No tecido conjuntivo subcutâneo de camundongos, o Ketac Cem Easymix apresentou resposta inflamatória e fenômenos reacionais intensos em todos os períodos analisados. Já o RelyX Unicem apresentou resposta inflamatória discreta com reparo tecidual nos períodos mais tardios. Podemos concluir que os cimentos RelyX Unicem e Ketac Cem Easymix apresentaram resultados satisfatórios, quando empregados na dentina de cavidades profundas, sem exposição pulpar. No entanto, quando em contato com o tecido conjuntivo subcutâneo e com o tecido pulpar em microexposições apresentaram resultados insatisfatórios.
The purpose of this study was to evaluate the biocompatibility of different luting agents (Ketac Cem Easy Mix 3M ESPE and RelyX Unicem 3M ESPE), microscopically, by means of implants in the subcutaneous connective tissue of isogenic mice; microscopically and radiographically, after application to deep cavities, close to the pulp, in dogs teeth. In the study in subcutaneous connective tissue, 40 isogenic BALB/c mice were allocated in 9 groups with 3 experimental periods: Group I: Ketac Cem Easy Mix® (7 days), Group II: RelyX Unicem (7 days), Group III: empty polyethylene tube (7 days), Group IV: Ketac Cem Easy Mix (21 days) Group V: RelyX? Unicem (21 days), Group VI: empty polyethylene tube (21 days), Group VII: Ketac Cem Easy Mix (63 days), Group VIII: RelyX Unicem (63 days), Group IX: empty polyethylene tube (63 days). In the study in the pulp tissue of dogs teeth, 40 teeth (80 roots) of 4 dogs were used and assigned to 6 groups: Group I: Ketac Cem Easy Mix (7 days), Group II: RelyX Unicem (7 days), Group III: zinc oxide and eugenol cement (7 days), Group IV: Ketac Cem Easy Mix (70 days) Group V: RelyX Unicem (70 days), Group VI: zinc oxide and eugenol cement (70 days). The microscopic analysis of the subcutaneous connective tissue was performed under standard ligth microscopy, according to the following parameters: presence of inflammatory infiltrate (cellularity and cell type) and tissue repair. In the microscopic analysis in dogs teeth, a comprehensive description of dentin, pulp and periapical tissue characteristics was undertaken, based on the following aspects: presence of normal pulp; presence of reparative dentin; presence of ulceration; presence of pulpitis; and presence of pulp necrosis. The radiographic evaluation was performed by means of the analysis of periapical radiographs taken before the operative procedures and at the experimental periods, with respect to the integrity of the lamina dura, presence or absence of root resorptions and areas of periapical bone rarefaction. The results of the microscopic analysis demonstrated that, when applied to dentin, both cements did not cause adverse pulp reactions. Nevertheless, when applied directly to the pulp tissue, the luting agents triggered an intense inflammatory response, with pulp necrosis and development of periapical reaction. In the subcutaneous connective tissue of mice, Ketac Cem Easymix induced an inflammatory response and intense reactive phenomena at all analyzed periods. On the other hand, RelyX Unicem induced a discrete inflammatory response with tissue repair at the later periods. It may be concluded that RelyX Unicem and Ketac Cem Easymix luting agents presented satisfactory results when applied to the dentin of deep cavities without pulp exposure. However, when placed in contact with the subcutaneous connective tissue and pulp tissue in areas of micro-exposures, these materials presented unsatisfactory results.
APA, Harvard, Vancouver, ISO, and other styles
31

Verardo, Olivia Santos de Oliveira. "Materiais obturadores: resposta tecidual após biopulpectomia em dentes de cães." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/58/58135/tde-19032010-114526/.

Full text
Abstract:
O objetivo do presente trabalho foi avaliar a resposta tecidual em 48 pré- molares (96 raízes) de cães, após obturação dos canais radiculares com diferentes materiais. Os dentes foram submetidos à biopulpectomia, ao preparo biomecânico e divididos em oito grupos, onde os canais radiculares foram obturados com os seguintes materiais: Grupos I e V pasta Calen® espessada com óxido de zinco; Grupos II e VI cimento EndoREZ; Grupos III e VII cimento Sealapex®, e Grupos IV e VIII cimento de óxido de zinco e eugenol. Decorridos os períodos de 30 e 90 dias, os animais foram mortos, as peças removidas e submetidas ao processamento histológico. A avaliação histopatológica foi baseada nos seguintes parâmetros: intensidade do infiltrado inflamatório, espessura do ligamento periodontal, reabsorção do tecido ósseo, limte de obturação e presença ou ausência de selamento apical. Os resultados foram submetidos à análise estatística pelo teste não paramétrico de Kruskal-Wallis, com nível de significância de 5%. Com base nos resultados obtidos e considerando as condições específicas deste trabalho, pôde-se concluir que a pasta Calen® espessada com óxido de zinco foi o material que apresentou a melhor resposta tecidual, seguida pelos cimentos Sealapex® e óxido de zinco e eugenol. O cimento EndoREZ apresentou resposta tecidual desfavorável .
The objective of the present work was evaluate the tissue response in 48 premolars( 96 roots), of dogs teeth, after pulpectomy, with different roots canals filling materials. The teeth were submitted to the biomechanical preparation and divided in eigth groups, where the canals were filled with following materials: Groups I and V - Calen® paste thickened with zinc oxide; Groups II and VI - EndoREZ sealer; Groups III and VII - Sealapex® sealer; and Groups IV and VIII Zinc oxide and eugenol cement. After periods of 30 and 90 days, the animals were killed, the pieces reduced and submitted to the histological processing. The histopathological evaluation was based on the following parameters: intensity of the inflammatory infiltrate, thickness of the periodontal ligament, bone resorption,filling limit and presence or absence of sealed apical. The results were submitted to the statistical analysis by the non parametric test of Kruskal-Wallis, with significance level was 5%. Based on the results obtained in histopathological analysis and methodologies employed in the present work, it may be conclued that: Calen® paste thickened with zinc oxide was the material that showed the better tissue response, following by Sealapex® sealer and zinc oxide and eugenol cement. EndoREZ sealer showed tissue response unfavorable.
APA, Harvard, Vancouver, ISO, and other styles
32

Zhou, Fuping. "Creeping flow behavior of dense granular materials under high confinement pressure." Access to citation, abstract and download form provided by ProQuest Information and Learning Company; downloadable PDF file, 197 p, 2006. http://proquest.umi.com/pqdweb?did=1172112591&sid=2&Fmt=2&clientId=8331&RQT=309&VName=PQD.

Full text
Abstract:
Thesis (Ph.D.)--University of Delaware, 2006.
Principal faculty advisors: Suresh G. Advani, Dept. of Mechanical Engineering, and Eric D. Wetzel, Army Research Laboratory. Includes bibliographical references.
APA, Harvard, Vancouver, ISO, and other styles
33

Alonso, Renata Camila Bruschi. "Colagem de fragmentos em dentes anteriores fraturados : efeito de materiais e tecnicas na resistencia ao impacto." [s.n.], 2007. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289577.

Full text
Abstract:
Orientador: Lourenço Correr Sobrinho
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-08T10:12:27Z (GMT). No. of bitstreams: 1 Alonso_RenataCamilaBruschi_M.pdf: 1462277 bytes, checksum: 2005c106fdedd696c9baa0d0a44fc8ca (MD5) Previous issue date: 2007
Resumo: O objetivo desse estudo foi avaliar in vitro o efeito de diferentes materiais e técnicas de colagem de fragmentos na resistência ao impacto de dentes anteriores, comparando-a com a resistência à fratura dos dentes hígidos. Para isso, foram selecionados 90 incisivos inferiores bovinos recém-extraídos, com dimensões da coroa de aproximadamente 15 mm de largura mésio-distal e 25 mm de comprimento inciso-cervical. Para a obtenção de fragmentos padronizados, foi realizada secção da coroa de 80 dentes a 12 mm da borda incisal com o uso de disco diamantado em cortadeira Isomet 1000. Remanescentes dentais e fragmentos foram submetidos ao ultrassom em banho de água por 2 horas para remoção da smear layer. Em seguida, os dentes foram embutidos em tubos de PVC com resina acrílica, e o ligamento periodontal foi simulado com poliéter (Impregum Soft). Os dentes seccionados foram distribuídos em 8 grupos (n=10), segundo os materiais e a técnica de colagem de fragmento: G1 - Colagem Direta (CD) + Single Bond (SB) + Filtek Z350 Flow (FF); G2 - CD + Clearfil SE Bond (CSE) + FF; G3 - CD + SB + Rely X CRA (RX); G4 - CD + CSE + RX; G5 - Chanfro Circunferencial (CC) + SB + FF; G6 - CC + CSE + FF; G7 - CC + SB + RX; G8 -CC + CSE + RX. O chanfro circunferencial foi confeccionado após o reposicionamento do fragmento utilizando ponta diamantada esférica (#1016) e, em seguida, restaurado com compósito Filtek Z250 (A3). Todos os materiais foram aplicados de acordo com as instruções dos fabricantes. Dez dentes foram mantidos hígidos para compor o grupo controle. Em seguida, as amostras foram armazenadas em água deionizada a 37oC, durante 24h e submetidas a acabamento e polimento utilizando pontas diamantadas (#3195 F/FF) e sistema Sof-Lex. Para análise da resistência ao impacto, as amostras foram posicionadas em uma máquina universal de testes mecânicos (Instron) de modo que uma carga compressiva foi aplicada na face vestibular a 2 mm do bordo incisal com velocidade de 500 mm/min até a fratura da amostra. Os dados obtidos foram submetidos à Análise de Variância e as médias comparadas pelo teste de Ryan-Einot-Gabriel-Welsch a 5% de significância. Os resultados obtidos, em Kgf, foram, em ordem decrescente: G controle - 64,8; G7 - 43,36; G5 - 37,82; G6 - 37,44; G8 - 26,68; G1 - 26,48; G3 - 23,59; G4 - 17,55; G2 -12,42. A técnica de colagem utilizando Chanfro Circunferencial foi significativamente superior à técnica de Colagem Direta. A utilização do sistema adesivo de condicionamento ácido total Single Bond promoveu aumento significativo na resistência ao impacto quando comparado ao sistema autocondicionante Clearfil SE Bond. Não houve diferença significativa entre os agentes cimentantes Rely X e Filtek Z350 Flow. Nenhuma técnica ou material considerado individualmente foi capaz de devolver ao dente restaurado a resistência mecânica do dente hígido. Somente a associação entre técnica de colagem com Chanfro Circunferencial e sistema de união Single Bond foi capaz de devolver ao dente restaurado a resistência mecânica do dente hígido
Abstract: The objective of this in vitro study was to evaluate the effect of different materials and reattachment techniques on the resistance to impact of anterior teeth and also to compare the resistance to fracture shown by both, sound and restored anterior teeth, considering the different reattachment techniques used. Ninety fresh bovine incisors with crown dimensions of approximately 15 mm of mesiodistal width and 25 mm of incisocervical length were selected. In order to obtain standardized fragments, 80 crowns was sectioned 12 mm from the incisal edge buy means of a diamond saw in an ISOMET 1000 machine. Dental remnants and incisal fragments were submitted to ultrasonic bath for 2 hours, so as to remove smear layer. After the teeth were mounted in PVC rings and embedded in acrylic resin, the periodontal tissue was simulated using polyether (Impregum Soft). The sectioned teeth were distributed in 8 groups (n=10) according to material and reattachment technique: G1 - Direct bonding (DB) + Single Bond (SB) + Filtek Z350 Flow (FF); G2 - DB + Clearfil SE Bond (CSE) + FF; G3 - DB + SB + Rely X CRA (RX); G4 - DB + CSE + RX; G5 - Circumferential Chamfer (CC) + SB + FF; G6 - CC + CSE + FF; G7 - CC + SB + RX; G8 - CC + CSE + RX. The circumferential chamfer was prepared after the bonding of the fragment by means of a spherical diamond point (# 1016). The chamfer was filled with the restorative composite Filtek Z250 (A3). All materials were applied according to the manufacturers' instructions. Ten sound teeth were used as control group. The embedded specimens were stored for 24 hours in deionized water at 37oC and then submitted to finishing and polishing procedures using diamond points (#3195F/FF) and the Sof-Lex system. To evaluate their resistance to impact, the specimens were positioned in a universal testing machine (Instron). A compressive load was applied on the buccal surface, 2 mm from the incisal edge and at a crosshead speed of 500 mm/min, until the failure. The resulting data were submitted to ANOVA One Way and Ryan-Einot-Gabriel-Welsch Multiple Range test at 5% significance. The results (Kgf), were, in decreasing order: G control - 64.8; G7 - 43.36; G5 - 37.82; G6 - 37.44; G8 - 26.68; G1 - 26.48; G3 - 23.59; G4 - 17.55; G2 - 12.42. The fragment reattachment using the circumferential chamfer technique showed results which were significantly better than those shown by direct bonding. In addition, the use of the conventional total-etching bonding system Single Bond caused a significant increase in impact resistance when compared to the use of the self-etching bonding system Clearfil SE Bond. There was no significant difference among the luting agents (Rely X and Filtek Z350 Flow). No technique or material, when individually considered, was capable of achieving the mechanical strength of the sound teeth. Only the association of reattachment technique using circumferential chamfer with the bonding system Single Bond was capable of giving back to the restored teeth the resistance to impact shown by the sound teeth
Mestrado
Materiais Dentarios
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
34

Yui, Karen Cristina Kazue. "Avaliação in vitro da efetividade de associações de agentes clareadores na alteração da cor de dentes manchados por pigmentos sangüineos /." São José dos Campos : [s.n.], 2006. http://hdl.handle.net/11449/101354.

Full text
Abstract:
Orientador: José Roberto Rodrigues
Banca: Marianne Spalding
Banca: Maria Antonio Pereira
Banca: Sérgio Eduardo de Paiva Gonçalves
Banca: Maria Amélia Máximo de Araújo
Resumo: O objetivo deste estudo foi avaliar in vitro a efetividade de três associações de materiais clareadores na técnica mediata de clareamento de dentes tratados endodonticamente. Foram utilizados 48 pré-molares humanos íntegros, pigmentados artificialmente com sangue humano. Após preparo biomecânico, os canais radiculares foram obturados e o tampão cervical foi confeccionado com 3mm de cimento de fosfato de zinco ao nível da junção amelo-cementária. Os dentes foram divididos em quatro grupos (n=12): C (controle, sem material clareador), A1 (perborato de sódio + água destilada), A2 (perborato de sódio + peróxido de carbamida a 10%) e A3 (perborato de sódio + peróxido de carbamida a 35%). Os materiais clareadores foram trocados aos sete e 14 dias. Concluiu-se que o perborato de sódio associado ao peróxido de carbamida (tanto a 10%, como a 35%) foi mais efetivo do que quando associado à água destilada.
Abstract: The aim of this study was to evaluate in vitro the effectiveness of three associations of bleaching agents on artificially stained pulpless teeth. Forty-eight recently extracted intact human premolars were stained by immersing them in human blood, and divided into four groups. All teeth were endodontically treated and 3mm of zinc phosphate cement was placed at the cementoenamel junction. The teeth were divided into one control group and three test groups (n=12): C) control group, without bleaching agent, A1) sodium perborate with water, A2) sodium perborate with 10% carbamide peroxide, A3) sodium perborate with 35% carbamide peroxide. On days 7 and 14, each pulp chamber was refilled with fresh bleaching paste. Color coordinates of CIELAB color system were measured and assessed with the aid of a dental spectrophotometer (EasyShade®, Vita). It was concluded that sodium perborate mixed with carbamide peroxide (10% or 35%) was more effective than mixed with water.
Doutor
APA, Harvard, Vancouver, ISO, and other styles
35

Garcia, Liliani Fernanda Marques. "Avaliação da resistência à fratura vertical de dentes tratados endodonticamente com diferentes materiais obturadores." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/23/23145/tde-24112009-114532/.

Full text
Abstract:
O presente estudo teve como objetivo avaliar comparativamente in vitro a resistência à fratura radicular de dentes tratados endodonticamente usando diferentes materiais obturadores: AH Plus (Dentsply/De Trey, Alemanha), Real Seal (Sybron Endo, EUA), GuttaFlow (Coltène/Whaledent, Suíça) , ActiV GP (Brasseler, EUA) e Thermafil (Dentsply-Tulsa Dental, EUA). Sessenta e quatro pré-molares inferiores foram divididos em Grupo Controle (n=4), onde as raízes não foram nem instrumentadas nem obturadas e outros 5 grupos de acordo com os materiais obturadores empregados: Grupo AH Plus (n=12); Grupo Real Seal (n=12); Grupo GuttaFlow (n=12); Grupo ActiV GP (n=12); Grupo Thermafil (n=12). As raízes foram instrumentadas com o sistema Protaper Universal (Dentsply-Maillefer, Suíça), e em seguida foram obturadas com os respectivos materiais. Após a obturação, todos os espécimes foram armazenados à 37º C com 100% de umidade por 72 horas e incluídos em resina acrílica. O ligamento periodontal foi simulado com Impregum, que formou uma fina camada entre a raiz e a resina acrílica. Os espécimes foram submetidos ao teste de resistência à fratura em uma máquina de ensaios triaxiais (1,0mm/min). Os valores médios obtidos e o desvio padrão (em Newtons) em ordem decrescente foram: Grupo controle 394,25 ± 56,17 N; Grupo ActiV GP 263 ± 89,32 N; Grupo Thermafil 198,17 ± 61,65 N; Grupo AH Plus 158,08 ± 31,56 N; Grupo Real Seal 154,92 ± 42,64 N e Grupo GuttaFlow 107,92 ± 20,72 N. Os dados foram submetidos aos testes ANOVA e Dunett (5%). Dentre os grupos experimentais, as raízes obturadas com ActiV GP mostraram-se mais resistentes à força vertical aplicada, porém similares aos grupos controle e Thermafil. Os grupos AH Plus, Real Seal e Thermafil mostraram-se similares estatisticamente quanto à resistência à fratura. O grupo GuttaFlow apresentou menores valores médios de resistência à fratura.
The aim of this study was to evaluate the in vitro vertical fracture resistance of endodontically treated teeth using different root filling materials: AH Plus (Dentsply/De Trey, Alemanha), Real Seal (Sybron Endo, EUA), GuttaFlow (Coltène/Whaledent, Suíça) , ActiV GP (Brasseler, EUA) and Thermafil (Dentsply- Tulsa Dental, EUA). Sixty four single-rooted human lower premolar were assigned into a Control Group (n=4), where the roots were not prepared or filled, and five experimental groups (n=12) according to the root filling materials: Group AH Plus; Group Real Seal; Group GuttaFlow; Group ActiV GP; Group Thermafil. The roots were prepared using Protaper Universal system (Dentsply-Maillefer, Suíça) and filled using one of the root filling materials. Then, the specimens were stored at 37º C at 100% humidity for 72 hours and included in acrylic resin. The periodontal ligament was simulated by the use of Impregum, which made a thin layer between the root and acrylic resin. The specimens were submitted to a vertical fracture resistance using a testing machine triaxiais (1,0mm/min). The values (Newton) and standard deviations obtained were: Control Group 394,25 ± 56,17N; Group ActiV GP 263 ± 89,32N; Group Thermafil 198,17 ± 61,65N; Group AH Plus 158,08 ± 31,56N; Group Real Seal 154,92 ± 42,64N and Group GuttaFlow 107,92 ± 20,72N. The data were submitted to ANOVA e Dunett tests (5%). Among the experimental groups, roots filled with ActiV GP showed the highest values of resistance of load vertical was applied, and were similar to Control Group and Thermafil. AH Plus, Real Seal and Thermafil groups showed statistical similar fracture resistance. GuttaFlow Group showed the lowest values of fracture resistance.
APA, Harvard, Vancouver, ISO, and other styles
36

Yui, Karen Cristina Kazue [UNESP]. "Avaliação in vitro da efetividade de associações de agentes clareadores na alteração da cor de dentes manchados por pigmentos sangüineos." Universidade Estadual Paulista (UNESP), 2006. http://hdl.handle.net/11449/101354.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-06-09Bitstream added on 2014-06-13T20:01:53Z : No. of bitstreams: 1 yui_kck_dr_sjc.pdf: 2075475 bytes, checksum: 65332c24d92e3b412ae98ae57ab0f400 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O objetivo deste estudo foi avaliar in vitro a efetividade de três associações de materiais clareadores na técnica mediata de clareamento de dentes tratados endodonticamente. Foram utilizados 48 pré-molares humanos íntegros, pigmentados artificialmente com sangue humano. Após preparo biomecânico, os canais radiculares foram obturados e o tampão cervical foi confeccionado com 3mm de cimento de fosfato de zinco ao nível da junção amelo-cementária. Os dentes foram divididos em quatro grupos (n=12): C (controle, sem material clareador), A1 (perborato de sódio + água destilada), A2 (perborato de sódio + peróxido de carbamida a 10%) e A3 (perborato de sódio + peróxido de carbamida a 35%). Os materiais clareadores foram trocados aos sete e 14 dias. Concluiu-se que o perborato de sódio associado ao peróxido de carbamida (tanto a 10%, como a 35%) foi mais efetivo do que quando associado à água destilada.
The aim of this study was to evaluate in vitro the effectiveness of three associations of bleaching agents on artificially stained pulpless teeth. Forty-eight recently extracted intact human premolars were stained by immersing them in human blood, and divided into four groups. All teeth were endodontically treated and 3mm of zinc phosphate cement was placed at the cementoenamel junction. The teeth were divided into one control group and three test groups (n=12): C) control group, without bleaching agent, A1) sodium perborate with water, A2) sodium perborate with 10% carbamide peroxide, A3) sodium perborate with 35% carbamide peroxide. On days 7 and 14, each pulp chamber was refilled with fresh bleaching paste. Color coordinates of CIELAB color system were measured and assessed with the aid of a dental spectrophotometer (EasyShade®, Vita). It was concluded that sodium perborate mixed with carbamide peroxide (10% or 35%) was more effective than mixed with water.
APA, Harvard, Vancouver, ISO, and other styles
37

Santos, Filho Paulo Cesar de Freitas. "Biodinamica restauradora de dentes tratados endodonticamente : analise por elementos finitos." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289704.

Full text
Abstract:
Orientador: Luis Roberto Marcondes Martins
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-13T11:40:25Z (GMT). No. of bitstreams: 1 SantosFilho_PauloCesardeFreitas_D.pdf: 10660151 bytes, checksum: bd3f67697b369623400074dcf22ec01c (MD5) Previous issue date: 2009
Resumo: O objetivo deste estudo foi desenvolver protocolo de modelagem tridimensional para incisivo central superior com aplicabilidade ao método de elementos finitos e avaliar o comportamento biomecânico de incisivo superior tratado endodonticamente e restaurado com retentores e coroa cerâmica por meio de análise por elementos finitos comparado ao dente hígido. Para geração do modelo 3D foi selecionado incisivo central superior hígido. Esmalte e dentina foram degradados em diferentes fases com ácido clorídrico-10%, e mapeados com scanner de contato 3D (Modela, Roland). Para o mapeamento do volume pulpar, a dentina foi seccionada longitudinalmente no sentido mesio-distal e realizado o escaneamento do espaço negativo referente à polpa. Os arquivos *.STL foram exportados para programa Bio-CAD (Rhinoceros-3D). Volumes de cada estrutura dental e técnicas restauradoras foram gerados por meio da associação de superfícies NURBS. Os modelos foram exportados para o programa de elementos finitos (FEMAP-NeiNastran), onde foi realizado o processo de malhagem, inserção das propriedades mecânicas e condições de contorno. Foram gerados 17 modelos, sendo um do dente hígido e 16 modelos de acordo com os 4 fatores em estudo: tipo de retentor em dois níveis: pino de fibra de vidro (PFV) e núcleo moldado fundido (NMF), extensão do retentor em dois níveis: 7,0mm (7,0) e 12,0mm (12,0), remanescente coronário em dois níveis: remanescente de 2,0mm (RE) e ausência de remanescente (ARE), enfraquecimento do canal radicular em dois níveis: ausência de enfraquecimento (AENF) e presença de enfraquecimento (ENF). Foi simulada aplicação de pressão constante no valor de 100N perpendicularmente à superfície palatina do incisivo. Os resultados foram analisados pelo critério de von Mises e tensão máxima principal. Os resultados obtidos mostraram que o modelo geométrico 3D desenvolvido é adequado para a análise por elementos finitos. Concluiu-se que o PFV apresenta distribuição homogênea das tensões mais semelhante ao dente hígido, enquanto o NMF apresentou grande concentração de tensão no interior do canal radicular. O fator extensão do retentor intra-radicular influenciou isoladamente apenas a distribuição de tensões do NMF. A presença de remanescente coronário sempre melhorou a distribuição de tensões. O enfraquecimento do canal radicular teve maior impacto na distribuição de tensões.
Abstract: The aim of this study was develop 3D model generation protocol for upper anterior teeth for finite element analysis and evaluate biomechanical behavior of endodontically treated incisor with finite element analysis compared to sound teeth. It was selected intact upper central incisor. Enamel and dentin were treated in different steps with cloridric acid 2% and scanned with 3D-contact scanner. The stereolithographics archives were exported to Bio CAD program. The volums of each dental structure and restorative techniques were generated by association of NURBS surfaces. The models were exported for finite element software, where were realized the meshed process, mechanical properties insertion and bondary conditions. It were generated 17 models, one was a sound incisor model and 16 models according to 4 studied factors: post type: glass fiber post (GFP) and cast post and core (CPC), post length: 7,0mm (7,0) e 12,0mm (12,0), ferrule: 2,0mm ferrule (FE) and absence of ferrule (AFE), weakness of root canal: absence of weakness (AWR) and weakened root (WR). It was simulated 100N loading application on the palatal surface with 135° angulation. The results were analised by Von Mises criteria and principal maximum tension. Obtained results showed that geometric model developed is appropriated for finite element analysis. It can be concluded that GFP showed homogeneous stress distribution like the sound incisor, while CPC showed stress concentration into root canal. The post length influenced only the CPC stress distribution. The ferrule always showed better stress distribution. The weakness of root showed the highest impact in stress distribution.
Doutorado
Dentística
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
38

Teixeira, Karla Nunes. "Resistência à fratura de diferentes materiais para retentores intrarradiculares." reponame:Repositório Institucional da UFSC, 2016. https://repositorio.ufsc.br/xmlui/handle/123456789/169245.

Full text
Abstract:
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016.
Made available in DSpace on 2016-10-18T03:08:30Z (GMT). No. of bitstreams: 1 342143.pdf: 3205659 bytes, checksum: 638cd711df5fc22fea49e0fe61264b4a (MD5) Previous issue date: 2016
O objetivo deste trabalho in vitro foi avaliar a resistência à fraturae o tipo de falha de novos materiais utilizados como retentoresintrarradiculares cimentados em condutos de raízes de dentes humanos.Foram selecionados 48 pré-molares inferiores, hígidos, com apenas umconduto radicular. Os dentes tiveram suas coroas seccionadas e oscondutos radiculares endodonticamente tratados e, na sequência,randomizados em 4 grupos (n = 12), conforme o material de composiçãodos pinos/núcleos: poliéter-éter-cetona (PEEK), resina composta comcarga nanocerâmica (RNC), núcleo metálico fundido com liga de níquelcromo(NMF) e pino de fibra de vidro reembasado com resina composta(PFC). As raízes foram incluídas em resina acrílica, os pinos/núcleoscimentados (todos com o mesmo cimento resinoso autoadesivo dual) e,em seguida, os espécimes foram armazenados em água destilada a 37°Cpor 60 dias. Na sequência, foram submetidos ao teste de resistência àfratura por compressão, a 0,5 mm/min sob um ângulo de 45° em relaçãoao eixo longitudinal do dente, em máquina de ensaio universal, até afratura. As fraturas foram classificadas como reparáveis e irreparáveis.Os valores de resistência à fratura assim obtidos foram submetidos aoteste estatístico ANOVA, com grau de confiança de 95%, para detectardiferenças estatísticas entre os grupos (p < 0,001). De acordo com o testePost-hoc Tukey, os resultados de resistência à fratura do Grupo NMF(939,61 N) foram estatisticamente superiores aos dos demais grupos (p <0,05), enquanto não houve diferença estatística entre os Grupos PFC(449,63 N), PEEK (396,07 N) e RNC (511,59 N) (p > 0,05). Falhasirreparáveis aconteceram em maior número no Grupo NMF (10).Também no Grupo RNC ocorreram duas falhas irreparáveis. Já nosGrupos PFC e PEEK todas as falhas foram consideradas reparáveis.Apesar de mostrar maior resistência à fratura, o Grupo NMF teve falhasirreparáveis, desfavoráveis ao retratamento. Um material de reconstruçãoradicular com alta resistência à fratura não garante que o complexoraiz/retentor intrarradicular fique protegido de uma falha catastróficacomo a fratura radicular.

Abstract : The aim of this in vitro study was to evaluate the fracture strengthand the type of failure of new materials used as intracanal retainers,visible in conduits of human teeth roots. We selected 48 premolars,healthy, with only one root canal. The teeth were sectioned crowns andendodontically root canal treated and, randomized into 4 groups (n = 12)as the material composition of post/cores: polyether ether ketone (PEEK)composite resin with nanoceramic load (CRN), molten metallic core withnickel-chromium alloy (NMF) and glass fiber post with composite resin(GFP). The roots were embedded in acrylic resin, the post/core cemented(all with the same resin cement dual self adhesive) and then thespecimens were stored in distilled water at 37°C for 60 days. In thefollowing, they were subjected to compression fracture resistance test at0.5 mm/min at an angle of 45° relative to the longitudinal axis of thetooth in an universal testing machine until fracture. Fractures wereclassified as repairable and irreparable. The fracture resistance valuesthus obtained were submitted to ANOVA, with confidence level of 95%to detect statistical differences between the groups, which have beenproven (p < 0.001). According to the Post-hoc Tukey test, resistance tofracture results of the NMF Group (939.61 N) were statistically superiorto the other groups (p < 0.05), whereas there was no statistical differencebetween the PFC (449.63 N), PEEK (396.07 N), and RNC (511.59 N)Groups (p > 0.05). Irreparable failures occurred in greater numbers in theNMF Group (10). Also in the CRN Group there were two irreparablefailures. Already in the PFC and PEEK Groups all faults were consideredrepairable. Despite showing greater resistance to fracture, the NMFGroup has irreparable flaws, unfavorable to retreatment. A rootreconstruction material with high fracture resistance does not guaranteethat the complex root/post and core be protected from a catastrophicfailure as the root fracture.
APA, Harvard, Vancouver, ISO, and other styles
39

Gaspar, Neil. "Structures and heterogeneity in deforming, densely packed granular materials." Thesis, Kingston University, 2001. http://eprints.kingston.ac.uk/20679/.

Full text
Abstract:
Predictions of the mechanical properties of a densely packed granular material so far have been quite inaccurate. Many of the phenomena observed by such a material leave a lot of unanswered questions. For example the stiffness of a sample under a strain path is poorly predicted by the most recent theoretical work. Part of the difficulty of a granular material is the interplay between discrete and continuous measures. For any sample of a practical scale, the size and numbers of grains involved makes consideration of each individual grain a near impossible process. So on the whole, continuum measures and theories have been used to try to describe the material behaviour without acknowledgement of the particulate constituents. However, that the mechanics of the material as a whole is dependent on the inter-particle forces is undeniable. These inter- particle forces work at the level of the individual particle where discrete measures such as force and displacements should be used. So how can practical, continuum measures be constructed from discrete constituents? This thesis provides the theoretical means to traverse from the discrete constituents to continuum measures. A key feature is the formalisation of a mesodomain, which is the unit of a granular material where the continuum and discrete regimes meet. Use is made of the formulation of a heterogeneous material to describe this mesodomain and it is shown how material properties can be scaled up from the mesoscale to the size of a sample of granular material. Work external to this project provides a method for describing the mechanics within the mesodomain. This is used to calculate the values of important tensors that represent the fabric of the mesodomain.
APA, Harvard, Vancouver, ISO, and other styles
40

Koda, Fábio. "Estudo da fadiga de contato em engrenagens cilíndricas de dentes retos." Universidade Tecnológica Federal do Paraná, 2009. http://repositorio.utfpr.edu.br/jspui/handle/1/183.

Full text
Abstract:
Devido à resistência dos fabricantes de automóveis quanto à utilização de engrenagens de FNA estudos tem sido feitos para averiguar o desempenho deste material em engrenagens. Dentro deste contexto esta dissertação tem como objetivos principais o desenvolvimento e construção de uma máquina de ensaios de fadiga de contato em engrenagens e a comparação quanto à resistência ao desgaste de engrenagens cilíndricas de dentes retos fabricadas em aço liga 8620 (cementado e temperado) e em ferro fundido nodular austêmperado (FNA). Estas engrenagens foram fornecidas em dois estados de acabamento superficial (shaving ou por fresamento). O equipamento desenvolvido funciona com o princípio de recirculação de potência e é comumente chamado de FZG. Os experimentos de desgaste têm sido feitos com dois estágios de torque: 135 N.m (running-in) e 302 N.m (steady-state) e as engrenagens são de perfil modificado. Após a realização dos ensaios, foi possível verificar que: (1) a área danificada dos flancos, devido ao fenômeno de pitting, das engrenagens de FNA foi maior do que das de aço AISI 8620; (2) a comparação entre os parâmetros de rugosidade nos estágio de fornecimento e após cada estágio do experimento mostra que as engrenagens com acabamento por shaving apresentam uma melhor distribuição da carga e um menor desgaste, (3) o regime de lubrificação na região do diâmetro primitivo durante os ensaios foi o limite (ou limítrofe) para ambos os processos de fabricação, porém o parâmetro de espessura de filme (λ) é maior para engrenagens fabricadas por shaving, fazendo com que a espessura do filme lubrificante seja maior, (4) o efeito da redução da área resistente aos esforços de contato, devido à presença dos nódulos de grafita, na resistência a fadiga foi evidenciado, porém o acabamento superficial mostrou-se mais relevante do que a distribuição e tamanho dos nódulos.
Due to the resistance of automotive manufactures on apply ADI gear studies have been made to verify the performance of this material. Inside this context this work has a main objective the construction of contact fatigue test machine in gears and the comparison, related to the wear resistance, between spur-gears made of carburized and quenched AISI 8620 low steel and austempered ductile iron (ADI). These gears were supplied in two states of finish surface (by shaving or by machining). The developed equipment functions with the principle of the power recirculation and commonly called FZG. The wear experiments were performed in two stages of torque: 135 N.m (running-in) and 302 N.m (steady-state) and the gears have modified profile. After the accomplishment of the experiments, was possible verify that: (1) The damaged area of flanks, due to the phenomenon of pitting, at ADI gears was bigger than AISI 8620 low-alloy steel gears. (2) The comparisons between the roughness parameter in the supply state and after each period of the experiment shows that gears with surface finish by shaving have better load distribution and minor wear. (3) Lubricant regime at pitch diameter was the boundary for both manufacture process, but the film thickness parameter λ is higher for shaved gears, making the lubricant film thickness has major value, (4) The reduction effect the resistive area of contact due the presence of the graphite nodules in the contact fatigue resistance was evidenced, however surface finishing was more relevant than the distribution and size nodules.
APA, Harvard, Vancouver, ISO, and other styles
41

Carneiro, Débora Ferreira. "Avaliação da citotoxicidade de materiais endodônticos no tratamento de perfurações radiculares." reponame:Repositório Institucional da UnB, 2010. http://repositorio.unb.br/handle/10482/7164.

Full text
Abstract:
Tese (doutorado)-Universidade de Brasília, Faculdade de Ciências da Saúde, 2010.
Submitted by Shayane Marques Zica (marquacizh@uol.com.br) on 2011-03-18T18:48:09Z No. of bitstreams: 1 2010_DeboraFerreiraCarneiro.pdf: 2035586 bytes, checksum: ee9d140bc73a527e588a16ce8b998da1 (MD5)
Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2011-03-19T19:55:48Z (GMT) No. of bitstreams: 1 2010_DeboraFerreiraCarneiro.pdf: 2035586 bytes, checksum: ee9d140bc73a527e588a16ce8b998da1 (MD5)
Made available in DSpace on 2011-03-19T19:55:48Z (GMT). No. of bitstreams: 1 2010_DeboraFerreiraCarneiro.pdf: 2035586 bytes, checksum: ee9d140bc73a527e588a16ce8b998da1 (MD5)
Perfurações radiculares podem ser seladas com auxílio de materiais endodônticos, que ficam em contato direto com as células do ligamento periodontal, podendo causar danos que retardem ou impeçam o processo de reparo. Os objetivos deste trabalho foram avaliar a citocompatibilidade dos extratos dos materiais endodônticos (Endofill, Sealer 26, cimento de Portland branco e Cimento de óxidos bioativos), recém espatulados e após 24 horas de presa, em contato com células do ligamento periodontal humano. Foram utilizados como parâmetros de análise a capacidade de proliferação, o potencial transmembrânico mitocondrial, as alterações morfológicas, o potencial genotóxico e as alterações no ciclo celular. As células do ligamento periodontal foram obtidas a partir da extração de quatro terceiros molares e cultivadas em laboratório, conforme protocolos de cultura de células. As análises dos efeitos foram realizadas por meio do teste MTT de viabilidade celular, análise microscópica e a citometria de fluxo utilizando como fluorocromos rodamina 123 e iodeto de propídio. O pH foi avaliado pela medição imediata do meio de cultura com extrato do cimento endodôntico com auxílio de pHmetro calibrado. Os resultados obtidos, após análise estatística (ANOVA a três fatores, com nível de significância p<0,05), revelaram que a composição dos materiais é o fator mais influente nas alterações celulares. Todos os materiais demonstraram algum grau de toxicidade para as células do ligamento periodontal dependendo da análise realizada. Somente o Endofill demonstrou toxicidade em todos os testes. Cimento de óxidos bioativos e o cimento de Portland branco não causaram alterações no potencial transmembrânico mitocondrial. Sealer 26, Sealer  e Cimento de Portland branco aumentaram o pH do meio e os dois primeiros também provocaram alterações morfológicas. Cimento de óxidos bioativos foi o que causou os menores danos ao DNA celular e, portanto, as menores alterações em ciclo celular. A citotoxicidade tende a diminuir à medida que a reação presa se completa. Apesar dos resultados, faz-se necessário continuar as pesquisas, com organismos vivos, para predizer e estabelecer a compatibilidade dos materiais. _______________________________________________________________________________ ABSTRACT
Root perforations can be sealed with the aid of endodontic materials, which are in direct contact with the periodontal ligament cells, may cause damage to slow or prevent the repair process. Our objectives were to evaluate the cytocompatibility of the extracts of endodontic materials (Endofill, Sealer 26, white Portland cement and bioactive oxides-based sealer), after contact for 24 hours with human periodontal ligament cells. The cell viability, the mitochondrial transmembrane potential, the morphological changes, the genotoxic potential and changes in the cell cycle were evaluated by MTT assay and flow cytometry. The periodontal ligament cells were obtained from the extraction of four third molars and cultured in the laboratory by cell culture protocols. The pH was measured at the material extract at varying time intervals with calibrated pHmeter. The results, after statistical analysis (ANOVA with three factor interaction, p <0.05), revealed that the composition of materials is the most influential factor in the cellular changes. All materials showed some degree of toxicity to the cells of periodontal ligament depending on the analysis. Only Endofill demonstrated toxicity in all tests. Bioactive oxides-based sealer and white Portland cement did not cause changes in mitochondrial transmembrane potential. Sealer 26, Sealer  and white Portland cement increased the pH of the medium and the first and second also caused morphological changes. Bioactive oxide-based sealer was what caused the least damage to cellular DNA and thus the smallest changes in the cell cycle. The cytotoxicity tends to decrease as the set reaction is complete. Despite the results, it is necessary to continue research with living organisms to predict and establish the compatibility of materials.
APA, Harvard, Vancouver, ISO, and other styles
42

Silva, Eduardo Galera da [UNESP]. "Estudo comparativo in vitro do efeito da ciclagem térmica sobre a resistência à tração de copings metálicos cimentados sobre dentes naturais, utilizando se de dois agentes cimentantes." Universidade Estadual Paulista (UNESP), 1997. http://hdl.handle.net/11449/131990.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:22:56Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-07-04. Added 1 bitstream(s) on 2015-12-10T14:29:10Z : No. of bitstreams: 1 000036232.pdf: 5393745 bytes, checksum: 5800df9fc12d98721c44be829a24048b (MD5)
O estudo avaliou a resistência ao teste de arrancamento de coroas totais metálicas (NiCrBe), cimentadas em dentes humanos naturais extraídos (terceiros molares), com preparos padronizados realizado num aparelho especialmente idealizado para tal, baseado no princípio do funcionamento do torno mecânico. As coroas foram cimentadas com cimento de fosfato de zinco e cimento adesivo de resina. O total da amostra foi de sessenta dentes e as respectivas coroas, divididas em trinta para o grupo controle e trinta para o grupo experimental. Para o grupo controle, imediatamente após as cimentações, os corpos de prova foram armazenados em água a 37ºC por 48h antes de serem submetidos ao teste de tração. Para o grupo experimental, anteriormente ao teste de arrancamento, os trinta corpos de prova foram submetidos à ciclagem térmica com variações de 6, 61 e 37ºC, num total de 8 mil ciclos. Os resultados mostraram para o grupo controle, coroas cimentadas com cimento de fosfato de zinco, uma resistência média de 32,33Kgf. Nas amostras cimentadas com Panavía 21 os dentes não resistiram à remoção das coroas dos respectivos preparos, ocorrendo fratura em 100% dos dentes. Para o grupo experimental, a resistência média oferecida ao teste de arrancamento pelas coroas cimentadas com cimento de fosfato de zinco foi de 27,63Kgf e para as cimentadas com Panavia Ex de 35,00Kgf. Em geral, os resultados mostraram uma diminuição da resistência à tração oferecida pelos agentes cimentantes, quando os corpos de prova foram submetidos previamente à cíclagem térmica. Surpreendentemente, houve uma grande variação em relação aos dados encontrados nos testes de tração, tanto para o cimento de fosfato de zinco como para o cimento de resina, sob as duas condições analisadas, sem e com ciclagem térmica
This study evaluated the tensile bond strenght of complete metal crowns (Ni Cr Be) bonded to sound natural extracted teeth on which standardized preparations were carried out with a special designed device based on the lathe principie. Crowns were luted with zinc phosphate cement and a resin adhesive cement (Panavia 21 ). 60 extracted third molars were separated in two groups of 30, the first was used as a control group and the second as a test group. For the control group, after luting the crowns to the prepared teeth the specimens were immersed in water at 37ºC and stored for 48h before being submitted to the tensile bond strenght test. For the test group, after luting the crowns to the prepared teeth, specimens were thermocycled with temperatura changes of 6, 61 and 37ºC to 8.000 cycles. Results for the control groups showed that crowns luted with ZPC presented a mean tensile strenght of 32,33kgf. Teeth with crowns luted with the resin adhesive cement showed fractures for all the specimens. Results for the test groups showed that specimens luted with ZPC presented a mean tensile strenght of 27,63kgf and those with Panavia Ex, 35,00kgf. Overall results showed reduced strenght when specimens were thermocycled prior to the tests. Unexpected results were found for both cements under thermocycling or not. Several teeth fractures ocurred during the tests, for both groups luted with both cements
APA, Harvard, Vancouver, ISO, and other styles
43

Silva, Eduardo Galera da. "Estudo comparativo in vitro do efeito da ciclagem térmica sobre a resistência à tração de copings metálicos cimentados sobre dentes naturais, utilizando se de dois agentes cimentantes /." São José dos Campos, 1997. http://hdl.handle.net/11449/131990.

Full text
Abstract:
Orientador: João Vieira de Moraes
Banca: Celso -Ite Tanaka
Banca: Maria Amélia Maximo de Araújo
Resumo: O estudo avaliou a resistência ao teste de arrancamento de coroas totais metálicas (NiCrBe), cimentadas em dentes humanos naturais extraídos (terceiros molares), com preparos padronizados realizado num aparelho especialmente idealizado para tal, baseado no princípio do funcionamento do torno mecânico. As coroas foram cimentadas com cimento de fosfato de zinco e cimento adesivo de resina. O total da amostra foi de sessenta dentes e as respectivas coroas, divididas em trinta para o grupo controle e trinta para o grupo experimental. Para o grupo controle, imediatamente após as cimentações, os corpos de prova foram armazenados em água a 37ºC por 48h antes de serem submetidos ao teste de tração. Para o grupo experimental, anteriormente ao teste de arrancamento, os trinta corpos de prova foram submetidos à ciclagem térmica com variações de 6, 61 e 37ºC, num total de 8 mil ciclos. Os resultados mostraram para o grupo controle, coroas cimentadas com cimento de fosfato de zinco, uma resistência média de 32,33Kgf. Nas amostras cimentadas com Panavía 21 os dentes não resistiram à remoção das coroas dos respectivos preparos, ocorrendo fratura em 100% dos dentes. Para o grupo experimental, a resistência média oferecida ao teste de arrancamento pelas coroas cimentadas com cimento de fosfato de zinco foi de 27,63Kgf e para as cimentadas com Panavia Ex de 35,00Kgf. Em geral, os resultados mostraram uma diminuição da resistência à tração oferecida pelos agentes cimentantes, quando os corpos de prova foram submetidos previamente à cíclagem térmica. Surpreendentemente, houve uma grande variação em relação aos dados encontrados nos testes de tração, tanto para o cimento de fosfato de zinco como para o cimento de resina, sob as duas condições analisadas, sem e com ciclagem térmica
Abstract: This study evaluated the tensile bond strenght of complete metal crowns (Ni Cr Be) bonded to sound natural extracted teeth on which standardized preparations were carried out with a special designed device based on the lathe principie. Crowns were luted with zinc phosphate cement and a resin adhesive cement (Panavia 21 ). 60 extracted third molars were separated in two groups of 30, the first was used as a control group and the second as a test group. For the control group, after luting the crowns to the prepared teeth the specimens were immersed in water at 37ºC and stored for 48h before being submitted to the tensile bond strenght test. For the test group, after luting the crowns to the prepared teeth, specimens were thermocycled with temperatura changes of 6, 61 and 37ºC to 8.000 cycles. Results for the control groups showed that crowns luted with ZPC presented a mean tensile strenght of 32,33kgf. Teeth with crowns luted with the resin adhesive cement showed fractures for all the specimens. Results for the test groups showed that specimens luted with ZPC presented a mean tensile strenght of 27,63kgf and those with Panavia Ex, 35,00kgf. Overall results showed reduced strenght when specimens were thermocycled prior to the tests. Unexpected results were found for both cements under thermocycling or not. Several teeth fractures ocurred during the tests, for both groups luted with both cements
Mestre
APA, Harvard, Vancouver, ISO, and other styles
44

Şimşek, Deniz Çiftçioğlu Muhsin. "Preparation and characterization of HA powders-dense and porous HA based composite materials/." [s.l.: [s.n.], 2002. http://library.iyte.edu.tr/tezler/master/malzemebilimivemuh/T000326.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
45

Lima, Regina Karla de Pontes [UNESP]. "Sistema adesivo na obturação de canais radiculares: biocompatibilidade e infiltração coronária (reparação apical e periapical em dentes de cães)." Universidade Estadual Paulista (UNESP), 2006. http://hdl.handle.net/11449/90393.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-05-30Bitstream added on 2014-06-13T20:31:49Z : No. of bitstreams: 1 lima_rkp_me_arafo.pdf: 1114536 bytes, checksum: 168f29b7a36e3e5efcd89c839651e545 (MD5)
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
O objetivo deste estudo foi o de avaliar, in vivo, a biocompatibilidade e a influência da infiltração, no sentido coroa/ápice, na reparação dos tecidos apicais e periapicais pós-tratamento endodôntico, utilizando dois diferentes materiais obturadores: o cimento Sealapex e um sistema resinoso de obturação de canal radicular denominado de sistema Epiphany/Resilon. Os resultados mostraram que o sistema Epiphany/Resilon apresentou resposta tecidual apical e periapical melhor que o cimento Sealapex, independente da presença ou não de restauração coronária, em todos os aspectos estudados. O sistema Epiphany/Resilon com restauração coronária apresentou melhores resultados que o mesmo sistema sem restauração coronária. O cimento Sealapex sofreu influência da infiltração coronária, apresentando, em todas as variáveis estudadas, os piores resultados, quando exposto ao meio bucal.
The objective of this study was to evaluate, in vivo, the biocompatibility and the leakage influence, in the crown-apex direction, in the endodontic post-treatment repairing of apical and periapical tissues, using two different filling materials: Sealapex sealer and a resinous cement of root canal filling - Epiphany/Resilon. The results showed that Epiphany/Resilon system presented apical and periapical tissue response better than Sealapex independent of presence or no of the coronary restoration, in all studied aspects. Epiphany/Resilon system, with coronary restoration presented better results than of the same system without coronary restoration. Sealapex was influenced by the coronary exposition to oral environment, presenting the worst results in all studied variables.
APA, Harvard, Vancouver, ISO, and other styles
46

Adabo, Gelson Luis. "Estudo do conteúdo de partículas inorgânicas, da contração de polimerização e da resistência à flexão de materiais restauradores estéticos diretos indicados para dentes posteriores /." Araraquara : [s.n.], 2000. http://hdl.handle.net/11449/116095.

Full text
Abstract:
Resumo: Recentemente, foram lançados no mercado odontológico novos materiais estéticos para restaurações diretas em dentes posteriores, aos quais são atribuídas propriedades mais adequadas para essa indicação. Entretanto, as informações disponíveis são ainda muito escassas, gerando dúvidas quanto à sua real eficácia, sobre quais as diferenças de suas composições e propriedades físicas e mecânicas em relação aos materiais até então disponíveis e se, de fato, apresentam melhor performance clínica. Em vista do exposto, nos propusemos a estudar contração de polimerização, resistência à flexão e concentração de partículas inorgânicas, por massa e volume, de sete resinas compostas (Alert, Ariston, Solitaire, Definite, Filtek P60, Z-100 e Tetric Ceram). A contração de polimerização foi medida nos materiais inseridos em um anel plástico, e o registro das alterações, durante a polimerização, foi feito por meio de instrumento eletrônico de medida linear, que registra as alterações dimensionais, com sensibilidade de 1 mm. A resistência à flexão foi medida na máquina de ensaios mecânicos MTS 810 e a confecção dos corpos-de-prova e dos dispositivos para o ensaio foi orientada pela norma ISO no 4049:1988. A determinação do conteúdo de partículas inorgânicas por massa foi feita através da pesagem de uma porção de resina composta polimerizada antes e após a eliminação da fase orgânica em forno, à temperatura de 700oC. O porcentual volumétrico de partículas inorgânicas foi calculado com base no Princípio de Arquimedes. Foi determinado o volume da resina composta polimerizada, antes e após a eliminação da fase orgânica, pela diferença da massa do material pesado ao ar e imerso em água. Os dados de conteúdo de partículas inorgânicas por massa e por volume, de contração de polimerização e resistência à flexão foram submetidos...(Resumo completo, clicar acesso eletrônico abaixo)
Abstract: Recently new esthetic materials for direct restorations in posterior teeth were introduced in the dentistry market, which were attributed properties more adequate for this indication. However, the information avaiable is still very scarce, producing uncertainty of its real efficacy. There is existence of doubts regarding the differences in composition, physical and mechanical properties related to the materials available and if, in fact, they present better clinical performance. Due to the exposed, we proposed to study the polymerization contraction, flexural resistance and concentration of inorganic particles by mass and volume of seven composite resins (Alert, Ariston, Solitaire, Definite, Filtek P60, Z-100 and Tetric Ceram). The polymerization contraction was measured with the materials inserted in a plastic ring. The registration of the alterations, during the polymerization was done through an electronic instrument of linear dimension with sensibiligy of 1um. The flexural resistance was measured by the MTS 810 mechanical test machine and the confection of the samples and the device for the tests were orientated by the ISO nº 4049:1998 norm. The determination of the content of inorganic particles per mass was made. A portion of composite resin was weighed before and after the elimination of the organic phase in an oven, at a temperature of 700ºC. The volume percentage of the inorganic particles was calculated based on the Arquimedes's Principle. The volume of ocmposite resin polymerized was determined before and after the elimination of the organic phase, by the difference in the mass of the material weighed in air and immersed in water. The data regarding the content of inorganic particles per mass and volume, polymerization contraction and flexural resistance...(Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
47

Martínez, Carreaux Francisco Javier. "Estudio Experimental de Flujos Granulares Densos." Tesis, Universidad de Chile, 2008. http://repositorio.uchile.cl/handle/2250/103197.

Full text
Abstract:
El estudio de los flujos granulares ha adquirido gran interés en las últimas décadas, no sólo por su impacto económico, ambiental y científico, sino también porque su ocurrencia a escala geológica genera grandes riesgos sobre la población y la infraestructura alrededor del mundo. Esto ha originado dentro del ámbito de la ingeniería la necesidad de contar con modelos dinámicos que sean capaces de predecir en forma confiable la evolución espacio temporal de estos fenómenos, para lo cual es fundamental identificar, caracterizar y cuantificar los mecanismos de interacción entre los granos. En este contexto, el presente trabajo tiene por objeto mostrar los resultados cuantitativos y cualitativos de un estudio experimental de flujos de materiales granulares densos y secos, generados en un canal de fondo deslizante. Este canal posee un largo útil de 3 m, paredes de vidrio de 40 cm de altura, un ancho útil de 18.6 cm y una cinta que desliza por el fondo a una velocidad que varía en el rango de 0 a 180 cm/s. Los materiales granulares utilizados en este experimento correspondieron a gravas finas, medianas y gruesas y esferas plásticas. A modo de comparación, se condujeron en forma paralela experimentos consistentes en flujos de esferas plásticas en un canal de fondo fijo de inclinación variable. Este canal posee un largo útil de 3 m, paredes de acrílico de 50 cm de altura y ancho útil de 20 cm. En ambas instalaciones, leyes de resistencia y parámetros adimensionales característicos fueron determinados a partir de las mediciones de altura, velocidad y pendiente del canal. También se obtuvieron imágenes del movimiento de las partículas en la pared del canal y en la superficie del flujo, usando una cámara de video de alta velocidad. Estas fueron analizadas posteriormente en forma cualitativa y cuantitativa, mediante procesos de tratamiento de imágenes y la aplicación de técnicas PIV (“Particle Image Velocimetry”) y PTV (“Particle Tracking Velocimetry”) para la obtención de la distribución de velocidades. A partir de las mediciones realizadas en esferas y sedimentos en el canal de fondo deslizante, se calcularon los números de Froude, Savage y Coulomb resultando ellos en el rango 0
APA, Harvard, Vancouver, ISO, and other styles
48

Penny, George B. S. "High-pressure synthesis of electronic materials." Thesis, University of Edinburgh, 2010. http://hdl.handle.net/1842/4161.

Full text
Abstract:
High-pressure techniques have become increasingly important in the synthesis of ceramic and metallic solids allowing the discovery of new materials with interesting properties. In this research dense solid oxides have been synthesised at high pressures, and structural investigations have been conducted using x-ray and neutron diffraction. The perovskite LaPdO3 has been synthesised at pressures of 6{10GPa. Neutron diffraction studies have been carried out from 7{260K to investigate any structural distortions, particularly related to the possibility of charge order at low temperatures. No reduction in symmetry associated with charge ordering has been observed; the material appears to remain metallic with only one unique Pd site down to 7K. LaPdO3 adopts the GdFeO3-type Pbnm structure. The PdO6 octahedra exhibit a tetragonal distortion throughout the temperature range with a shortening of the apical Pd{O bonds of 2:5% relative to the equatorial bonds. Attempts to prepare analogues of the perovskite containing smaller rare earths have resulted in multi-phase samples, and further RPdO3 perovskites remain inaccessible although there is evidence for a small amount of the perovskite phase in the products of synthesis attempts with neodymium. Three new oxypnictide superconductors, RFeAsO1 xFx (R = Tb, Dy and Ho) have been synthesised at 7{12GPa. The materials are isostructural with other recently discovered iron arsenide superconductors and have Tc's of 52:8 K, 48:5K and 36:2K respectively, demonstrating a downturn in Tc in the series for smaller R. Systematic studies on TbFeAsO0.9F0.1 and HoFeAsO0.9F0.1 show negative values of dTc=dV in contrast to those reported for early R containing materials. Low-temperature neutron diffraction measurements on both materials, and synchrotron studies on HoFeAsO0.9F0.1 reveal no tetragonal to orthorhombic transitions as observed in early R-containing materials with lower doping levels. Magnetic reflections are evident but they are shown to be from R2O3 and RAs impurities with TN's of 5:5K for Tb2O3, 6:5K for HoAs and 1:7K < TN < 4K for Ho2O3. The implications of these results for superconductivity in the iron arsenides are discussed.
APA, Harvard, Vancouver, ISO, and other styles
49

Murata, Sueli Satomi [UNESP]. "Análise histomorfológica de dentes decíduos de cães após biopulpectomia e obturação dos canais com diferentes materiais." Universidade Estadual Paulista (UNESP), 2002. http://hdl.handle.net/11449/95472.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-12-03Bitstream added on 2014-06-13T19:15:14Z : No. of bitstreams: 1 murata_ss_me_araca.pdf: 1986263 bytes, checksum: b2d0f830125168244f41777cc63efd3e (MD5)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
A busca de um material ideal para a obturação dos canais de dentes decíduos, até então não alcançada, motivou a realização deste estudo, o qual analisou, histomorfologicamente, os resultados do emprego de 3 materiais obturadores. Assim, os canais radiculares de 80 dentes decíduos, anteriores de 6 cães da mesma ninhada, e com 60 dias de idade, foram empregados neste estudo. Após o preparo biomecânico, os canais radiculares foram obturados com os seguintes materiais: Pasta lentamente reabsorvível de Maisto, Sealer 26 com iodofórmio, Pasta L&C e, como grupo controle, dentes com canais preparados e não obturados.Trinta dias após o tratamento, os animais foram sacrificados e os espécimes preparados para análise histomorfológica. A análise estatística dos resultados permitiu que os materiais estudados fossem ordenados, em conformidade com o melhor ao pior resultado, da seguinte forma: a) Pasta lentamente reabsorvível de Maisto, b) Sealer 26 com iodofórmio, c) Controle, d) Pasta L&C. Ocorreu diferença estatisticamente significante (0,1%) apenas entre os resultados dos diferentes grupos e os da Pasta L&C. Verificou-se, ainda que a Pasta L&C mostrou incompatibilidade biológica e que os demais materiais foram biocompatíveis, porém, suas velocidades de reabsorção não acompanharam a das raízes dos dentes decíduos.
The problem of finding an ideal material for filling root canals of deciduous teeth was not solved until now. This fact stimulated the development of an experimentation to analyze histomorphologically 3 root canal filling materials. Eighty root canals of dogs deciduous anterior teeth from 6 animals, 60 days old, were employed in this study. After the biomechanical preparation the root canals were filled with the following materials: slowly resorbible Maisto paste, Sealer 26 with iodoform, L&C paste (calcium hydroxide with olive oil) and as control group, canals that were prepared but not filled. Thirty days after the treatment the animals were sacrificed and the pieces prepared for histomorphological analysis. The statistical analysis ordered the materials from the best to the worse results in the following way: a - Maisto paste, b - Sealer 26 with iodoform, c - control group, d - L&C paste. There was significant difference (0.1%) only when the studied groups were compared with the L&C paste group. There was also observed that L&C paste was not biologically compatible and that the other materials were biocompatible but its resorption was not in the same rate as the one of the deciduous teeth roots.
APA, Harvard, Vancouver, ISO, and other styles
50

Ismail, Mohamed Ismail Abdelaziz Mohamed. "Rapid material interrogation using X rays from a dense plasma focus." Diss., Kansas State University, 2015. http://hdl.handle.net/2097/18981.

Full text
Abstract:
Doctor of Philosophy
Department of Mechanical and Nuclear Engineering
William L. Dunn
Dense Plasma Focus (DPF) devices are multi-radiation sources of X rays, neutrons (when working with deuterium), ions, and electrons in pulses typically of a few tens of nanoseconds. The Kansas State University device (KSU-DPF) was commissioned to be used as a radiation source with the Mechanical and Nuclear Engineering Department. The device is operated by a 12.5 µF capacitor which can be charged up to 40 kV storing an energy of 10 kJ. The static inductance and resistance of the device L[subscript]0 and r[subscript]0 were measured to be 91±2 nH and 13±3 mΩ. Experiments have shown that the KSU-DPF device produces 2.45 MeV neutrons with a neutron yield of ~2 × 10^7 and 1.05 × 10^7 n/shots in both axial and radial directions. Ions up to 130 keV were measured using a Faraday Cup. The measured hard X-ray spectrum shows an X-ray emission in the range from 20 to 120 keV with a peak at 50 keV while the average effective energy was estimated, using a step filter method, to be 59±3 keV. The KSU-DPF device was used as a pulsed hard X-ray source for material interrogation studies using the signature-based radiation-scanning (SBRS) technique. The SBRS technique uses template matching to differentiate targets that contain certain types of materials, such as chemical explosives or drugs, from those that do not. Experiments were performed with different materials in cans of three sizes. Nitrogen-rich fertilizers and ammonium nitrate were used as explosive surrogates. Experiments showed 100% sensitivity for all sizes of used samples while 50% specificity for 5 and 1- gallon and 28.57% for quart samples. Simulations using MCNP-5 gave results in good agreement with the experimental results. In the simulations, a larger number of materials, including real explosives were tested. To ensure the feasibility of using the DPF devices for this purpose a second device was simulated and the results were encouraging. Experimental and simulation results indicate that use of DPF devices with simple, room-temperature detectors may provide a way to perform rapid screening for threat materials, especially for places where large number of packages need to be investigated.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!