Academic literature on the topic 'Continuous Passive Motion'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Continuous Passive Motion.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Continuous Passive Motion"

1

Scarlet, JJ. "Continuous passive motion." Journal of the American Podiatric Medical Association 86, no. 4 (April 1, 1996): 189–90. http://dx.doi.org/10.7547/87507315-86-4-189.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

London, Nicholas J., Margaret Brown, and Raymond J. Newman. "Continuous Passive Motion." Physiotherapy 85, no. 11 (November 1999): 616–18. http://dx.doi.org/10.1016/s0031-9406(05)66042-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

&NA;. "Continuous Passive Motion." Back Letter 8, no. 6 (June 1993): 5. http://dx.doi.org/10.1097/00130561-199306000-00004.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Reinecke, Steven M., Rowland G. Hazard, and Kevin Coleman. "Continuous Passive Motion in Seating." Journal of Spinal Disorders 7, no. 1 (February 1994): 29–35. http://dx.doi.org/10.1097/00002517-199407010-00004.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Dent, J. A. "Continuous passive motion in hand rehabilitation." Prosthetics and Orthotics International 17, no. 2 (August 1993): 130–35. http://dx.doi.org/10.3109/03093649309164369.

Full text
Abstract:
This paper reviews the literature comparing the results obtained in applying regimes involving motion with those involving rest following injury or surgery. The deleterious effects of immobilisation are compared to those obtained under conditions of passive motion and intermittent passive motion. It is concluded that continuous passive motion (CPM) represents an improvement on intermittent motion. Models of CPM machines are described and some results presented. It is proposed that “intelligent” CPM would represent a further improvement in technique and a prototype machine for this purpose and some preliminary results are described.
APA, Harvard, Vancouver, ISO, and other styles
6

&NA;. "DOES CONTINUOUS PASSIVE MOTION HELP KNEES?" AJN, American Journal of Nursing 87, no. 8 (August 1987): 1012–13. http://dx.doi.org/10.1097/00000446-198708000-00004.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Smith, Jane E. "APPLYING THE CONTINUOUS PASSIVE MOTION DEVICE." Orthopaedic Nursing 9, no. 3 (May 1990): 54???56. http://dx.doi.org/10.1097/00006416-199005000-00009.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

SOETERS, J., R. VANDOLDER, and S. HOVIUS. "A modified continuous passive motion apparatus." Journal of Hand Surgery: Journal of the British Society for Surgery of the Hand 15, no. 3 (August 1990): 386–87. http://dx.doi.org/10.1016/0266-7681(90)90030-8.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Carpenter, Charlotte V. E., and Rouin Amirfeyz. "Continuous Passive Motion Following Elbow Arthrolysis." Journal of Hand Surgery 39, no. 2 (February 2014): 350–52. http://dx.doi.org/10.1016/j.jhsa.2013.11.040.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Hussein Mohammed Al-Almoodi, Hamzah, Norsinnira Zainul Azlan, Ifrah Shahdad, and Norhaslinda Kamarudzaman. "Continuous Passive Motion Machine for Elbow Rehabilitation." International Journal of Robotics and Control Systems 1, no. 3 (October 22, 2021): 402–15. http://dx.doi.org/10.31763/ijrcs.v1i3.446.

Full text
Abstract:
Continuous Passive Machines (CPM) facilitate patients in eliminating joint stiffness after surgery and lead to a faster and more efficient recovery. However, many previous CPM machined are mechanically complicated, expensive, and lack a user interface. This paper presents a new CPM machine for elbow flexion-extension and forearm pronation-supination. The machine is simple, low-cost, and equipped with Graphical User Interface (GUI). Its mechanism is designed so that it can be used on the left or right arms interchangeably. It is developed using aluminum, perspex, and steel rods. The electrical part of the machine consists of Arduino Uno to drive the motors and a potentiometer to measure the patients’ Range of Motion (ROM). The GUI for setting the exercise parameters and monitoring the patients’ progress has been developed using MATLAB software. The experimental results show that the machine has successfully provided the repetitive desired motions. The machine realizes elbow flexion-extension and forearm pronation-supination movements with 0ᵒ-135ᵒ and 0ᵒ-90ᵒ ranges of motion (ROM), respectively. The machine is also capable of increasing the elbow joint’s ROM by 5ᵒ increments for the therapy. The results show that the machine has the potential to be used in hospitals and rehabilitation centers.
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Continuous Passive Motion"

1

Parsons, Erin M. "Control system design for a continuous passive motion machine." Connect to resource, 2010. http://hdl.handle.net/1811/45477.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Bittikofer, Raymond P. "A computer controlled continuous passive motion device for ankle rehabilitation." Ohio : Ohio University, 1994. http://www.ohiolink.edu/etd/view.cgi?ohiou1176838831.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Cooper, Rosa M. "A Policy Guide to Decrease the Use of Continuous Passive Motion Machines." ScholarWorks, 2015. https://scholarworks.waldenu.edu/dissertations/1437.

Full text
Abstract:
A Policy Guide to Decrease the Use of Continuous Passive Motion Machines by Rosa M. Cooper MSN, Walden University, 2009 BSN, Immaculata University, 2007 Project Submitted in Partial Fulfillment of the Requirements for the Degree of Doctor of Nursing Practice Walden University August 2015 This project was conducted at a post-acute rehabilitation hospital that served post-acute orthopedic, stroke, brain injury, cardiac, and skilled nursing patients. On the orthopedic unit, there were 5 practicing physicians, 3 of whom consistently used continuous passive motion (CPM) therapy on total knee arthroplasty (TKA) and 2 of whom did not. As a result of discussions with physicians who did and did not utilize CPM therapy, a practice problem was identified that CPM use may not be consistent with current literature and practice evidence. Scholarly literary reviews were done on current CPM evidence- based research. Observational data were collected on patients' ambulatory function, knee range of motion, and pain durance. This information was then presented by the interdisciplinary team (IDT), which consisted of the physical therapist, occupational therapist, and nurses. The physicians input along with the observational data obtained by the IDT all supported the hypothesis that CPM usage did not promote faster healing nor added a benefit to patient outcomes. A project to revise the existing CPM policy and develop a guide decreasing CPM usage was implemented and guided by the theories of organization change and a total quality management model. The purpose of this quality assurance project is to promote a cost-effective practice change that would be beneficial to the TKA population as it relates to care and treatment. As the increase in TKA continues to rise in the United States due to such co-morbidities as obesity causing an increase in disabilities, implementing the best practice as it relates to patient outcomes brings about a positive social change.
APA, Harvard, Vancouver, ISO, and other styles
4

Carus, David Alexander. "The effect of cyclic forces upon finger joints with impaired ranges of motion." Thesis, University of Abertay Dundee, 1998. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.313131.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Callegaro, Aline Marian. "DESENVOLVIMENTO DE UM EQUIPAMENTO COMPUTADORIZADO DE MOVIMENTAÇÃO PASSIVA CONTÍNUA PARA COTOVELO E ANTEBRAÇO." Universidade Federal de Santa Maria, 2010. http://repositorio.ufsm.br/handle/1/8151.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
This research demonstrates the development of a new principle of operation for elbow and forearm continuous passive motion (CPM) equipment. For that were integrated knowledges of Physical Therapy and Production Engineering to make a prototype of a CPM device for the purpose of enabling the programming of various sequences of passive movements of elbow and forearm by means of computerized numerical control (CNC). The conceptual design of prototype mechanical equipment was carried out, as well as the construction and development of a program to specify the principles of operation of the equipment. Computerized CPM allows the independent or synchronized passive movements on two axes: elbow flexion/extension and forearm pronation/supination. The prototype has stepper motors connected to a microcomputer by means of drivers. The motors are controlled by commercial CNC machine software control. The language read and interpreted by this program is generated by other software, this was developed for this equipment to facilitate its use by the Physical Therapists. It has language accessible to this professionals and it allows the insertion of such variables as time and angle. The software calculates the speed of movement with these variables automatically. Data entered into the program are saved and generate a text file with standard CNC language, which is recognized by the program control. The sequences of movements are created by Physical Therapist and adapted to patients according to treatment goals and the individual characteristics. The control software also provides the flexion/extension and pronation/supination range of motion (ROM) passive evaluation, the data of each patient can be stored for monitoring progress and possible reuse. Based on what was done, we can assert that this operating principle can be used in CPM device, the software developed can be used on any machine of this type wich CNC principle of operation and if them have the availability of two axes of movement. This technique can be used to other equipments specific to the health area.
Neste trabalho é demonstrado o desenvolvimento de um novo princípio de operação para equipamentos de movimentação passiva contínua (CPM) para cotovelo e antebraço. Foram integrados conhecimentos de Fisioterapia e Engenharia de Produção para construir um protótipo de um equipamento de CPM que possibilite a programação de variadas sequências de movimentos passivos do cotovelo e antebraço por meio de técnicas empregadas em equipamentos com Comando Numérico Computadorizado (CNC). Foi realizado o projeto conceitual da mecânica do protótipo, sua posterior construção e desenvolvido um programa para especificar os princípios de operação do equipamento. O CPM Computadorizado possibilita os movimentos passivos independentes ou sincronizados em dois eixos: flexão/extensão do cotovelo e pronação/supinação do antebraço. Possui motores de passo, conectados a um microcomputador por meio de driveres. Os motores são comandados por um software controle comercial de máquina CNC. A linguagem lida e interpretada por este programa é gerada por outro software, o qual foi desenvolvido para este equipamento, visando facilitar a utilização pelo fisioterapeuta. Ele disponibiliza, em linguagem acessível ao profissional da área, a inserção de variáveis como tempo e ângulo, com as quais calcula automaticamente a velocidade de movimento. Os dados inseridos no programa são salvos e geram um arquivo texto com linguagem CNC padronizada reconhecida pelo programa controle. As sequências de movimentos são criadas pelo fisioterapeuta e adaptadas aos pacientes, de acordo com os objetivos do tratamento e as características individuais. O software controle proporciona também uma avaliação passiva da amplitude de movimento (ADM) da flexão/extensão e pronação/supinação e os dados de cada paciente podem ser armazenados para acompanhamento da evolução e possível reutilização. Com base no que foi realizado, é possível afirmar que este princípio de operação pode ser empregado em equipamentos de CPM e o software desenvolvido pode ser utilizado em qualquer máquina deste tipo com princípio de operação CNC, onde exista a disponibilidade de dois eixos de movimentos. Esta técnica ainda pode ser utilizada em outros equipamentos específicos da área da saúde.
APA, Harvard, Vancouver, ISO, and other styles
6

Callegaro, Aline Marian. "Desenvolvimento e otimização de um equipamento inovador para a reabilitação do cotovelo e antebraço." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2015. http://hdl.handle.net/10183/127802.

Full text
Abstract:
A prestação de serviços na área da saúde apresenta uma demanda por novas tecnologias. Os fisioterapeutas utilizam desde equipamentos mais simples aos mais complexos para auxiliar na elaboração do diagnóstico cinético funcional, na prescrição, planejamento, ordenação, análise, supervisão e avaliação das atividades fisioterapêuticas dos clientes. Considerando a importância da articulação do cotovelo para as atividades de vida diárias dos indivíduos, bem como a complexa reabilitação das articulações do cotovelo e radioulnares, que requerem intervenção precoce para evitar a rigidez articular, a perda de amplitude de movimento e de força; foi identificada a necessidade de desenvolver um equipamento inovador para a reabilitação do cotovelo e antebraço. Assim, essa tese tem como objetivo geral desenvolver um equipamento inovador para a reabilitação do cotovelo e antebraço. Os objetivos específicos são: (i) analisar os estudos científicos e patentes que abordam o desenvolvimento de equipamentos de Movimentação Passiva Contínua para a reabilitação do cotovelo e antebraço; (ii) realizar a análise funcional e operacional de equipamentos para a reabilitação do cotovelo a antebraço disponíveis no mercado; (iii) identificar os requisitos dos stakeholders da cadeia de valor do produto para o desenvolvimento de um equipamento inovador para a reabilitação do cotovelo e antebraço; (iv) desenvolver o módulo de vibração muscular localizada do equipamento inovador para a reabilitação do cotovelo e antebraço; (v) desenvolver o módulo de Movimentação Passiva Contínua do equipamento inovador para a reabilitação do cotovelo e antebraço; (vi) avaliar a utilização do equipamento inovador para a reabilitação do cotovelo e antebraço em seres humanos. Para atingir os objetivos desta tese foram utilizadas metodologias e ferramentas para a gestão do processo de desenvolvimento de produtos, bem como testes experimentais dos protótipos funcionais com seres humanos. Os resultados envolvem a obtenção de conhecimento científico acerca do tema do desenvolvimento de equipamentos inovadores para a área da saúde, bem como o protótipo funcional de um equipamento inovador para a reabilitação do cotovelo e antebraço, apresentados na forma de seis estudos científicos.
The healthcare service rendering requests new technologies. Physical therapists use equipments from the simplest to the most complex to assist in the developing of functional kinetic diagnosis, prescription, planning, managing, analyzing, monitoring and evaluation of customers’ therapy activities. A need of developing a novel equipment for the elbow and forearm rehabilitation came from the importance of the elbow joint for the daily living activities of people and the complex rehabilitation of elbow and radioulnar joints. These joints require early intervention to prevent joint stiffness, loss of range of motion and strength. Based on this context, the general goal of this PhD thesis is to develop a novel device for elbow and forearm rehabilitation. The specific goals are: (i) analyze the scientific studies and patents about the development of Continuous Passive Motion devices for the elbow and forearm rehabilitation; (ii) analyze functional and operationally the devices for the elbow and forearm rehabilitation which are available in the market; (iii) identify the stakeholder requirements of the device value chain to develop a novel device for the elbow and forearm rehabilitation; (iv) develop the local muscle vibration module of the novel device for the elbow and forearm rehabilitation; (v) develop the Continuous Passive Motion module of the novel device for the elbow and forearm rehabilitation; (vi) evaluate the use of the novel device for the elbow and forearm rehabilitation on human subjects. Management product development process methodogies and tools, as well as experimental tests of the functional prototypes on human subjects were used to achieve the thesis goals. The results include the generation of scientific knowledge about the development of new devices for the health area, as well as a functional prototype of the novel equipment for the elbow and forearm rehabilitation presented as six scientific studies.
APA, Harvard, Vancouver, ISO, and other styles
7

Abolfathi, Peter Puya. "Development of an Instrumented and Powered Exoskeleton for the Rehabilitation of the Hand." University of Sydney, 2008. http://hdl.handle.net/2123/3690.

Full text
Abstract:
Doctor of Philosophy (PhD)
With improvements in actuation technology and sensory systems, it is becoming increasingly feasible to create powered exoskeletal garments that can assist with the movement of human limbs. This class of robotics referred to as human-machine interfaces will one day be used for the rehabilitation of paralysed, damaged or weak upper and lower extremities. The focus of this project was the development of an exoskeletal interface for the rehabilitation of the hands. A novel sensor was designed for use in such a device. The sensor uses simple optical mechanisms centred on a spring to measure force and position simultaneously. In addition, the sensor introduces an elastic element between the actuator and its corresponding hand joint. This will allow series elastic actuation (SEA) to improve control and safely of the system. The Hand Rehabilitation Device requires multiple actuators. To stay within volume and weight constraints, it is therefore imperative to reduce the size, mass and efficiency of each actuator without losing power. A method was devised that allows small efficient actuating subunits to work together and produce a combined collective output. This work summation method was successfully implemented with Shape Memory Alloy (SMA) based actuators. The actuation, sensory, control system and human-machine interface concepts proposed were evaluated together using a single-joint electromechanical harness. This experimental setup was used with volunteer subjects to assess the potentials of a full-hand device to be used for therapy, assessment and function of the hand. The Rehabilitation Glove aims to bring significant new benefits for improving hand function, an important aspect of human independence. Furthermore, the developments in this project may one day be used for other parts of the body helping bring human-machine interface technology into the fields of rehabilitation and therapy.
APA, Harvard, Vancouver, ISO, and other styles
8

Liang, Shu-Ting, and 梁舒婷. "Assessment of knee behaviors when using a continuous passive motion device." Thesis, 2005. http://ndltd.ncl.edu.tw/handle/57336746892847764172.

Full text
Abstract:
碩士
長庚大學
復健科學研究所
94
Background and Purpose: All joints should be moved after the operation to prevent the stiff or deterioration of peripheral joint. Continuous passive motion instrument (CPM) is an external motorized device and it enables a joint to move passively. At presents, it becomes one of selection of rehabilitation therapy tool. In the past study, although the joint influenced by the speed and relevant joints when was stretched repeatedly. But it did not aim at the parameters of CPM instrument such as the regulation of postures and velocities during the CPM machine motion in clinical. The purpose of this study was to investigate the consistency of joint angle with CPM instrument. Methods: Two electrogoniometers were used to record the varied range of motion of knee joint and the CPM machine. The first thing was to confirm angles shown on the operation panel with the real angle monitored on the CPM machine. The measurement of consistency of joint angle was to expect asking for thirty healthy subjects and five patients following the knee problem. In the study, it had two topic groups and separated the different velocities (slow, moderate, and fast) and postures (supine-lying, semi-lying, and upright). They were randomized assign to an item of the different topic groups. Results: There were statistically significant different between CPM and CPM (EG) of flexion (p<0.001) and extension (p<0.001). There were statistically significant different between CPM (EG) and knee at all velocities (p<0.001) and all postures (p<0.001) in the control group, there were not statistically significant different between the velocities in all times (p>0.05). There were statistically significant different between the postures in all times (p<0.05). In the patient group, there were not statistically significant different between the velocities and postures in all times (p>0.05). The angle differences of the patient group were smaller than the control group in all condition. Conclusion: Although the CPM machine and CPM(EG) had highly correlation within full range, it had lower correlation at start to flex or extend about 40°. The differences between CPM machine and CPM(EG) were not over 10°. There were no consistency between the angle of CPM (EG) and knee at all velocities and postures. The angle differences did not significant change by velocities, but it significant changed by postures. And the different mainly occurred in the upright posture. But the changes did not significant occur on the patient group. Clinical Relevance: It suggested that the angles were not consistent entirely during the CPM machine motion. To obtain treatment effects, we should calibrate on a regularly and consider the angle differences at all condition.
APA, Harvard, Vancouver, ISO, and other styles
9

Huang, Pei-Shan, and 黃珮珊. "The research and development of a continuous passive motion machine for wrist and hand." Thesis, 2004. http://ndltd.ncl.edu.tw/handle/92894889100694737254.

Full text
Abstract:
碩士
國立陽明大學
復健科技輔具研究所
92
Background and objective:There are many reasons that cause hand disease through clinical examinations, such as fracture, tendon rupture, burns, arthritis etc. Rehabilitation is often used to prevent from evolved hand disease. Therefore, the purpose of this study is to build a hand CPM (continuous passive motion) machine for rehabilitation. The machine is designed according to the suggestions of the orthopedists and physical therapists and the function refers to the rehabilitative motions which are radial deviation, ulnar deviation, extension, hyperextension of wrists and adduction, abduction, flexion, extension of fingers. Methods:The research process is divided into three phases. The first phase is to conduct a literature review and to sum up the criteria such as motions, angles, and forces of the machine. The second phase goes on to design the mechanism and manufacture of the machine according to the criteria, and followed with the safety and functional tests of the machine. Finally, the third phase is to examine the Colles’ fracture patients who use the machine and investigate the patients through the process of rehabilitation in order to verify the validities by the clinical examinations. Results:It shows that this study of rehabilitation machine is not only to reach the functional requests of wrist and fingers, but also to increase the patient’s ROM(Range of motion). After the six weeks of rehabilitation, the average value of progress of the three subjects’ wrist flexion was 、wrist hyperextension was 、wrist radial deviation was 、wrist radial deviation was .Besides, there was no one hurt in the clinical examinations. Conclusion:The rehabilitation machine of this study includes both wrist and hand rehabilitation, and user can adjust the parameters which are time, pressure, pulling force and angle. The rehabilitation machine of this study has verified its efficacy under the clinical examinations.
APA, Harvard, Vancouver, ISO, and other styles
10

Chang, Chih-zen, and 張智仁. "Development of the Human Hand Motor Control Assessment and Continuous Passive Motion Rehabilitation Training System." Thesis, 2000. http://ndltd.ncl.edu.tw/handle/96972116542116102792.

Full text
Abstract:
碩士
長庚大學
機械工程研究所
88
Impairment of volitional motor activity is common after stroke, head injury, spinal cord injury and other conditions of upper motor neuron dysfunction. This finding is particularly relevant in stroke patients who have achieved substantial recovery of speech and gait, but volitional motor activity of the hand remained incomplete or absent. Therefore, the evaluation and training of the hand motor control functions become an important part of the rehabilitation therapy for these patients. In view of the above, this study is made aimed at the clinical needs of the upper motor neuropathy patients by combining the efforts of doctors, rehabilitation therapists and engineers and by integrating the sensors, computerized images, feedback controls and computer technologies for developing and pioneering a human hand motor control assessment and training system as well as a hand continuous passive motion rehabilitation training system for the patients. This study will be proceeded by dividing it into three parts, the first part was using the 5DT gloves available in the market and combining which with the hardware units of hand/palm pressure measurement module, digit hand-writing pad module and biofeedback hand dexterity assessment, training module, etc. to design and develop a hand motor control assessment and training system, whose functions include: articulation activity real time measurement and display, hand/palm pressure measurement, virtual 3D palm interaction display, hand-writing performance evaluation, etc.; the second part was to design a hand continuous passive motion (CPM) mechanical glove, which has 5 tendon driven fingers, each has a 2 degree of freedom. With the aid of interacting windows and post-treatment database, the goal of continuous passive motion and functional movement training can then be achieved. While the third part was using the hand motor control assessment and training system developed in to use to carry out clinical evaluations and experiments on hand motor control functions for 13 normal individuals and 26 patients with focal dystonia (such as patients with writer''s cramp). Tests were conducted in 2 modes of: writing without wearing the glove, writing by wearing the glove with hand/palm pressure sensors. The main evaluation items included as follows : the hesitation time during writing, the number of letters written, the delay time for starting writing, the contact pressure of hand against paper during writing, the contact pressure of hand against pen during writing. The experimental were analyzed. The results showed apparent differences between normal subject and patients with writing contraction disease, for example, the average hesitation time per letter of the patient group was 3.5 times longer than that of the normal subject group, the delay time for starting writing of the former group was 2.25 times as longer as that of the latter, moreover, the pen/paper contact pressures of the former were 1.43 times higher than those of the latter. With the accomplishment of this study, the developed hand motor control assessment and continuous passive motion rehabilitation training system not only can be immediately provided for evaluation and rehabilitation training by the clinical physicians for patients with hand motor control function disorders, but also can be synchronously used to collect physical signals (such as articulation activity degrees, finger/palm pressures, etc.) of the patients during the course of rehabilitation training. Quantitative index introduces in this study may be used for evaluating the therapeutic effects of the palm motor control functions of the patients. Besides, the prototype of the pioneered system should have the potential of applying for patent, and the design conception, software/hardware of the developed system can be transferred to the relevant medical industries in order to inspire the interest of people in researching, developing and manufacturing high-tech rehabilitation treatment apparatus, thus promote the upgrading of domestic medical care industry.
APA, Harvard, Vancouver, ISO, and other styles

Books on the topic "Continuous Passive Motion"

1

Salter, Robert Bruce. Continuous passive motion (CPM): A biological concept for the healing and regeneration of articular cartilage, ligaments, and tendons : from origination to research to clinical applications. Baltimore: Williams & Wilkins, 1993.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Salter, Robert Bruce. Textbook of disorders and injuries of the musculoskeletal system: An introduction to orthopaedics, fractures, and joint injuries, rheumatology, metabolic bone disease, and rehabilitation. 3rd ed. Baltimore: Williams & Wilkins, 1999.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Textbook of disorders and injuries of the musculoskeletal system. 3rd ed. Baltimore: Williams & Wilkins, 1999.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Zarnett, Mark Eric Rick. The cellular origin of neochondrogenesis produced by periosteal grafts subjected to continuous passive motion. 1985.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Rodger, Robert Mark. The immunological fate of allogeneic periosteum transplanted into an osteochondral defect and exposed to continuous passive motion. 1987.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

Effects of continuous passive motion and immobilization on synovitis and cartilage degradation in antigen-induced arthritis: An experimental investigation in the rabbit. Ottawa: National Library of Canada, 1996.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

Salter, Robert. Continuous Passive Motion: A Biological Concept for the Healing and Regeneration of Articular Cartilage, Ligaments, and Tendons : From Origination to Research to Clinical. Williams & Wilkins, 1992.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

Murnaghan, John J. *. The effect of continuous passive motion on the prevention of intra-articular adhesions as a complication of surgical synovectomy of the knee joint: an experimental investigation in the rabbit. 1989.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

Arthur, Richard T. W. Monads, Composition, and Force. Oxford University Press, 2018. http://dx.doi.org/10.1093/oso/9780198812869.001.0001.

Full text
Abstract:
This book offers a fresh interpretation of Leibniz’s theory of substance, taking as starting point his claims that he introduced his monads to solve the problem of the composition of the continuum. It is argued that they can only perform this function if they are understood as requisites for each of the actual parts into which matter is divided, and as sources of the actions distinguishing and making actual these parts. Bodies are not composed of monads, but presuppose them for their reality; and motions are not composed of monadic states, but presuppose their tendencies to change and resist changes. This comprises an original contribution to mereology, which is given a formal rendering using Leibniz’s own logical concepts and notation. The reading is supported by a thorough analysis of the development of Leibniz’s thought, showing how his embodied monads emerge from his long dalliance with atomism, and how his doctrine of dominant and subordinate monads derives from his immersion in the scholastic tradition of the Plurality of Forms, as he seeks to preserve the role of substantial forms in enacting God’s providential plans in a way compatible with a thoroughgoing mechanism. New insight is offered into Leibniz’s construal of bodies and motions as phenomena, his simultaneous advocacy of simple and corporeal substances, his attempt to provide a theory of substantial bonds, the status of passive force in his dynamics, his endorsement of continuous creation and the discreteness of change, and the status of monadic states as momentary.
APA, Harvard, Vancouver, ISO, and other styles
10

Fung, C. Victor. Complementary Bipolar Continua in Music Education. Oxford University Press, 2018. http://dx.doi.org/10.1093/oso/9780190234461.003.0005.

Full text
Abstract:
Classic Confucianism and classic Daoism were inspired by Yijing and were established during a period of nihilism. Both philosophical schools value human lives, expect individuals to improve continuously by self-cultivation, and recognize the world as a living organism. Despite their different emphases of dao, they are compatible to a great extent. For most people, it is necessary to utilize the different emphases to maintain a healthy diet, much like eating different types of food at different times of the day. Based on principles of yin and yang, the author proposes four complementary bipolar continua: active and passive musical motions, music teacher and learner roles, high-energy and low-energy activities, and familiar and unfamiliar musical experiences. The chapter ends with an explanation on how the complementary bipolar continua are connected among themselves and with the broader life.
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Continuous Passive Motion"

1

Deaconescu, Andrea, and Tudor Deaconescu. "Pneumatic Equipment for Ankle Rehabilitation by Continuous Passive Motion." In Advances in Service and Industrial Robotics, 13–21. Cham: Springer International Publishing, 2020. http://dx.doi.org/10.1007/978-3-030-48989-2_2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Friemert, B., C. Bach, W. Schwarz, and H. Gerngroß. "Bewegungsschienen in der Nachbehandlung der VKB-Plastik — „controlled active motion“ versus „continuous passive motion“ / Motion Machines in Treatment of ACL Reconstructed Patients: “Controlled Active Motion” Versus “Continuous Passive Motion”." In Deutsche Gesellschaft für Chirurgie, 393. Berlin, Heidelberg: Springer Berlin Heidelberg, 2001. http://dx.doi.org/10.1007/978-3-642-56458-1_135.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Ang, C. T., N. A. Hamzaid, Y. P. Chua, and A. Saw. "Continuous Passive Ankle Motion Device for Patient Undergoing Tibial Distraction Osteogenesis." In IFMBE Proceedings, 112–15. Berlin, Heidelberg: Springer Berlin Heidelberg, 2011. http://dx.doi.org/10.1007/978-3-642-21729-6_31.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Kantar, Susanna Stignani, and Isabella Fusaro. "Rehabilitation, Use of Elbow Braces, and Continuous Passive Motion After Elbow Arthroplasty." In Elbow Arthroplasty, 303–20. Cham: Springer International Publishing, 2019. http://dx.doi.org/10.1007/978-3-030-14455-5_29.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Friemert, B., C. Bach, W. Schwarz, and H. Gerngroß. "Bewegungsschienen in der Nachbehandlung von Patienten mit VKB-Plastik — “controlled active motion” versus “continuous passive motion”." In Deutsche Gesellschaft für Chirurgie, 413–15. Berlin, Heidelberg: Springer Berlin Heidelberg, 2001. http://dx.doi.org/10.1007/978-3-642-56698-1_107.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Shen, Zefang, Tele Tan, Garry Allison, and Lei Cui. "A Customized One-Degree-of-Freedom Linkage Based Leg Exoskeleton for Continuous Passive Motion Rehabilitation." In Mechanisms and Machine Science, 518–26. Cham: Springer International Publishing, 2018. http://dx.doi.org/10.1007/978-3-030-03320-0_57.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Wall, Alun, and Tim Board. "The Biological Effect of Continuous Passive Motion on the Healing of Full-Thickness Defects in Articular Cartilage. An Experimental Investigation in the Rabbit." In Classic Papers in Orthopaedics, 437–39. London: Springer London, 2013. http://dx.doi.org/10.1007/978-1-4471-5451-8_111.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

BATAVIA, M. "Continuous Passive Motion." In Contraindications in Physical Rehabilitation, 714–22. Elsevier, 2006. http://dx.doi.org/10.1016/b978-141603364-6.50053-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

O'Driscoll, Shawn W. "Continuous Passive Motion." In Morrey's The Elbow and Its Disorders, 160–63. Elsevier, 2009. http://dx.doi.org/10.1016/b978-1-4160-2902-1.50015-2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Morrey, Bernard F. "Continuous Passive Motion." In Morrey's the Elbow and its Disorders, 171–72. Elsevier, 2018. http://dx.doi.org/10.1016/b978-0-323-34169-1.00015-2.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Continuous Passive Motion"

1

de Paula Cintra Borges, Isabella, João Carvalho, and Rogério Sales Gonçalves. "A Continuous Passive Motion Aquatic Device." In 24th ABCM International Congress of Mechanical Engineering. ABCM, 2017. http://dx.doi.org/10.26678/abcm.cobem2017.cob17-0661.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Saputra, Michael Kharis, and Aulia Arif Iskandar. "Development of automatic Continuous Passive Motion therapeutic system." In 2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME). IEEE, 2011. http://dx.doi.org/10.1109/icici-bme.2011.6108630.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Uetsuji, Sakura, Nattawat Kingsuvangul, Boonyawee Boonyasurakul, and Warakorn Charoensuk. "Hand exoskeleton for continuous passive motion postoperative rehabilitation." In 2017 10th Biomedical Engineering International Conference (BMEiCON). IEEE, 2017. http://dx.doi.org/10.1109/bmeicon.2017.8229149.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Schievelbein, Guilherme, Cristina Paludo Santos, and Alexandre dos Santos Roque. "Fuzzy control methodology for continuous passive motion equipment." In 2016 IEEE International Conference on Automatica (ICA-ACCA). IEEE, 2016. http://dx.doi.org/10.1109/ica-acca.2016.7778433.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Deaconescu, Tudor T., Andrea I. Deaconescu, Sio-Iong Ao, Alan Hoi-Shou Chan, Hideki Katagiri, and Li Xu. "Pneumatic Muscle Actuated Equipment for Continuous Passive Motion." In IAENG TRANSACTIONS ON ENGINEERING TECHNOLOGIES VOLUME 3: Special Edition of the International MultiConference of Engineers and Computer Scientists 2009. AIP, 2009. http://dx.doi.org/10.1063/1.3256258.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Haghshenas-Jaryani, Mahdi, Wei Carrigan, Caleb Nothnagle, and Muthu B. J. Wijesundara. "Sensorized soft robotic glove for continuous passive motion therapy." In 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob). IEEE, 2016. http://dx.doi.org/10.1109/biorob.2016.7523728.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Viswanathan, M., M. Jorgensen, N. Kittusamy, and F. Biggs. "69. Field Evaluation of a Continuous Passive Lumbar Motion System." In AIHce 2005. AIHA, 2005. http://dx.doi.org/10.3320/1.2758659.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Alipour, A., and M. J. Mahjoob. "A rehabilitation robot for continuous passive motion of foot inversion-eversion." In 2016 4th International Conference on Robotics and Mechatronics (ICROM). IEEE, 2016. http://dx.doi.org/10.1109/icrom.2016.7886763.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Dubey, Sarthak, Rishabh Berlia, Shubham Kandoi, Theja Ram Pingali, Anurag Shivaprasad, Arpit Anand Varshney, Niranjana Krishnadas, and Niharika A. Patel. "Semi-automatic continuous passive motion physiotherapeutic device for post stroke patients." In 2014 International Conference on Circuits, Communication, Control and Computing (I4C). IEEE, 2014. http://dx.doi.org/10.1109/cimca.2014.7057783.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Rajestari, Z., N. Feizi, and S. Taghvaei. "Kinematic synthesis and optimization of Continuous Passive Motion mechanisms for knee." In 2017 7th International Conference on Modeling, Simulation, and Applied Optimization (ICMSAO). IEEE, 2017. http://dx.doi.org/10.1109/icmsao.2017.7934896.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography