Academic literature on the topic 'Conception de prothèse dentaire'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Conception de prothèse dentaire.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Conception de prothèse dentaire"
Rüttimann, M., G. Mion, and E. Racy. "Perforation œsophagienne par prothèse dentaire." Réanimation Urgences 6, no. 5 (November 1997): 653–55. http://dx.doi.org/10.1016/s1164-6756(97)80195-8.
Full textBuron, Corentin, Isabelle Floch, Philippe Maignan, and Guy Le Toux. "Impaction d’une prothèse dentaire dans l’intestin grêle." La Presse Médicale 47, no. 11-12 (November 2018): 1015–19. http://dx.doi.org/10.1016/j.lpm.2018.09.012.
Full textROZE-PELLAT, M. A., H. CAO, A. R. PARANQUE, T. HOUR, and T. NATHAN. "Traitement et appareillage des mutilés de la face : contribution de la mise en charge immédiate sur implants de prothèse complète amovible mandibulaire chez l’édenté total." Médecine et Armées Vol. 41 No. 5, Volume 41, Numéro 5 (December 1, 2013): 403–8. http://dx.doi.org/10.17184/eac.6700.
Full textHEMRI, Fodhil, and Mhania GUERTI. "Correction Par Réseaux De Neurones Artificiels Des Troubles D’articulé Dentaire Chez Un Locuteur Arabophone." AL-Lisaniyyat 23, no. 1 (June 19, 2017): 9–25. http://dx.doi.org/10.61850/allj.v23i1.263.
Full textChoël, Léon, Jacques Descotes, Brigitte Grosgogeat, and Brigitte Nicolas. "Toxicologie des matériaux rencontrés au laboratoire de prothèse dentaire." EMC - Odontologie 14, no. 3 (1998): 1. https://doi.org/10.1016/s1283-0860(98)23779-1.
Full textReichelt, Joana, German Bär, Frank Poerschke, Helmut Stark, Norbert Enkling, and Dominik Kraus. "Nouvelle procédure pour la réalisation de prothèses totales intégrée au flux de travail numérique." SWISS DENTAL JOURNAL SSO – Science and Clinical Topics 127, no. 11 (November 13, 2017): 976–83. http://dx.doi.org/10.61872/sdj-2017-11-05.
Full textB, Coulibaly. "Evaluation des besoins en prothèse dentaire chez les patients au service d'hépato-gastroentérologie du CHU-Gabriel Touré de Bamako." Mali Santé Publique 10, no. 02 (April 20, 2021): 40–43. http://dx.doi.org/10.53318/msp.v10i02.1795.
Full textAparicio, Guillaume, Saidou Diallo, Bertrand Leroux, Odile Bajolet, Veronique Vernet, Christophe Strady, and Emile Dehoux. "Infection secondaire d’origine dentaire sur prothèse articulaire à propos de neuf cas." Revue de Chirurgie Orthopédique et Traumatologique 97, no. 7 (November 2011): S337. http://dx.doi.org/10.1016/j.rcot.2011.08.242.
Full textHildebrand, Hartmut F., Christian Veron, Khalid Elagli, and Michel Donazzan. "Réactions tissulaires au port des appareils de prothèse dentaire partielle ou totale." EMC - Odontologie 11, no. 1 (1995): 1. https://doi.org/10.1016/s1283-0860(95)23767-9.
Full textDeguenonvo, R. "La prothèse dentaire, un corps étranger œsophagien dangereux : à propos de 14 cas." Annales françaises d'Oto-rhino-laryngologie et de Pathologie Cervico-faciale 131, no. 4 (October 2014): A131—A132. http://dx.doi.org/10.1016/j.aforl.2014.07.286.
Full textDissertations / Theses on the topic "Conception de prothèse dentaire"
Denis, Corentin. "Variations dimensionnelles d'une céramique dentaire alumineuse mise en forme par technique additive." Electronic Thesis or Diss., Université de Lille (2022-....), 2024. http://www.theses.fr/2024ULILS050.
Full textAn additive manufacturing method for dental ceramics was developed at Ceramaths, part of the Polytechnic University of Hauts-de-France. Previous work has shown that using alumina ceramic suspensions with 80% solid content by weight, vat photopolymerization enables the shaping of infrastructure ceramics with mechanical properties that meet current dental requirements. Indeed, ceramic frameworks must adhere to strict specifications regarding their fit precision to the dental preparation and their mechanical properties.Ceramic parts fabricated using additive techniques exhibit anisotropic shrinkage (different shrinkage rates along the three dimensions of a sintered part compared to its initial volume) following thermal debinding and densification treatment. The prosthetic part must be oversized to ensure the restoration adapts to the dental preparation after thermal treatment and to minimize the risk of restoration failure. A study on shrinkage rates and deformations of parts with increasingly complex geometries was conducted. These different part morphologies were digitized using microtomography, and the files were analyzed using inspection and control software.In the study of simple parallelepiped morphologies, variations in layer width and the number of layers showed anisotropic shrinkage rates, equivalent in the direction perpendicular to the forming process but higher in the forming direction. Shape variations of the simplified models do not influence the different shrinkage rates. The maximum acceptable viscosity depends on the layer surface area as well as the distance between two surfaces, which impacts the deformations due to the forming process and thermal treatment.The dimensional study of hollow cylindrical parts showed that the larger the layer surface area, the greater the risk of defects, and the orientation of the part also influences deformations during thermal treatment. The optimal orientation must therefore be a compromise between manufacturing time, limiting deformations with the smallest possible layer surface area, and ensuring optimal mechanical properties.Following the study of deformations in a clinical crown framework, the results in terms of forming accuracy showed that the manufacturing process combining the CryoPrinter® (Cryoceram®) printer, CryoCeram® resin, and CT 1200SG® alumina (Almatis®) is reproducible regardless of the forming orientation. The accuracy values of the printed restorations were below the 120 μm threshold except for the marginal zone when the mesio-distal orientation was chosen. The occluso-cervical orientation produced the most accurate restorations relative to the digital model at the marginal level. Lastly, the occlusal gap values were significantly lower for the occluso-cervical orientation compared to the vestibulo-palatal orientation, with the latter being the only one also presenting a mean marginal gap value below 120 μm. Thus, for shaping using the process developed by CryoCeram®, the occluso-cervical orientation seems preferable for producing clinically acceptable crown frameworks.Finally, an evaluation of the non-cytotoxicity of the parts formed using this new process was conducted to consider potential clinical use
Lebon, Nicolas. "Impact de l'usinage par CFAO sur l'intégrité de surface des prothèses dentaires coronaires." Thesis, Sorbonne Paris Cité, 2017. http://www.theses.fr/2017USPCD031/document.
Full textThe rehabilitation of dental function following the fitting of prostheses obtained by CAD/CAM is one of the major challenges of modern restorative dentistry. The quality of these prostheses can be assessed using roughness, corresponding to a major surface integrity (SI) component in dentistry. This thesis work aims to evaluate and quantify the influence of the characteristics associated with various milling tools, the materials used, and the parameters associated with the milling process on the residual roughness. The achieved results obtained during this work show a rather limited influence of the feedrate on the roughness, whereas those related to the size of the tool micro-geometry, the tool/prosthesis inclination, and the biomaterials are more significant. The importance of using a roughness parameters set in order to obtain a maximum of information relating to the surface topology is also demonstrated. This in turn leads to the definition of machining process performance indicators for the multi-physical and multi-indicator SI evaluation. The validation of the approach through a case study shows that a topological decomposition of the crown is necessary in order to better respect the prosthetic specifications and to provide valuable assistance to the practitioner or the laboratory technician. Each topological region can thus be machined using different machining strategies, be evaluated by a set of its own roughness parameters set, and undergo a post-processing polishing treatment, if necessary
Molé, Christian. "Intérêt des techniques physiologiques de conception de prothèses adjointes totales chez les musiciens joueurs d'un instrument à vent." Nancy 1, 1989. http://docnum.univ-lorraine.fr/public/SCDPHA_TD_1989_MOLE_CHRISTIAN.pdf.
Full textCharles, Alain. "Les différentes conceptions de l'enregistrement des surfaces d'appui à la mandibule en prothèse adjointe complète." Nantes, 1986. http://www.theses.fr/1986NANT1605.
Full textAmram, Wilio. "L' occlusion en prothèse complète." Aix-Marseille, 1985. http://www.theses.fr/1985AIX21065.
Full textLe, Gall Élisabeth. "Le montage des dents postérieures en prothèse adjointe complète." Nantes, 1986. http://www.theses.fr/1986NANT1589.
Full textDebry, Christian. "Conception, réalisation et expérimentation d'une prothèse laryngée totale." Paris 13, 1994. http://www.theses.fr/1994PA132049.
Full textAyme, Jean-Claude, and Jacques Emery. "L'adhésion, élément de bio-intégration des prothèses totales : essais de modifications expérimentales de l'énergie de surface des bases prothétiques par des procédés de métallisation et des traitements physico-chimiques." Nancy 1, 1988. http://www.theses.fr/1988NAN10517.
Full textBuch, Danielle. "Étude des propriétés viscoélastiques des matériaux de bases prothétiques." Paris 5, 1991. http://www.theses.fr/1991PA05M112.
Full textButin, Côme. "Conception et réalisation d'une nouvelle prothèse de main myoélectrique accessible." Electronic Thesis or Diss., Ecole centrale de Nantes, 2023. http://www.theses.fr/2023ECDN0021.
Full textThe main objective of this thesisis to present an accessible myoelectric handprosthesis that combines criteria such as affordability,durability, functionality, and performance.This new prosthesis allows for bothlateral and opposing grips. Firstly, we proposea method for joint placement that achieves amore realistic anthropomorphic result. Additionally,we have developed and optimized aninterdigital transmission solution that enablesthe coordination of the flexion between the upperfingers and the thumb. A detailed analysisof the prosthesis’s energy and thermalperformance is also provided. We have proposeda new control strategy that takes advantageof the irreversibility of power transmissionand thoroughly studied it. Furthermore,we emphasize the importance of achievingoptimal energy-efficient power transmission.To this end, we describe in detail the synthesisof a new mechanism with variable reductionratio and present a new efficient irreversibilitymechanism. Finally, we individuallyevaluate all these prosthesis componentsby implementing experimental prototypes thatdemonstrate their usefulness. The integrationof these components into a new prosthesis isa prospective direction explored in this study
Books on the topic "Conception de prothèse dentaire"
Owall, Bengt. Prothèse dentaire: Principes et stratégies thérapeutiques. Paris: Masson, 1998.
Find full textBehin, Pascal. Pratique clinique des matériaux dentaires en prothèse fixee. Paris: Editions Cdp, 1997.
Find full textR, Cagna David, DeFreest Charles F, and Stewart Kenneth L, eds. Stewart's clinical removable partial prosthodontics. 4th ed. Hanover Park, IL: Quintessence Pub., 2008.
Find full textKoffi, Justin. La PROTHÈSE PARTIELLE AMOVIBLE AU QUOTIDIEN - Plan de traitement conception-tracé des châssis approche qualité prothèses obturatrices. Paris: Editions L'Harmattan, 2009.
Find full textM, Chakravartula Ayyana, ed. Mechanics of biomaterials: Fundamental principles for implant design. Cambridge: Cambridge University Press, 2011.
Find full textTraité de Prothèse Buccale et de Mécanique Dentaire... Creative Media Partners, LLC, 2023.
Find full textTraité de Prothèse Buccale et de Mécanique Dentaire... Creative Media Partners, LLC, 2023.
Find full textFundamentals of fixed prosthodontics. 4th ed. Hanover Park, IL: Quintessence Pub., 2012.
Find full textPruitt, Lisa A., and Ayyana M. Chakravartula. Mechanics of Biomaterials: Fundamental Principles for Implant Design. Cambridge University Press, 2012.
Find full textPruitt, Lisa A., and Ayyana M. Chakravartula. Mechanics of Biomaterials: Fundamental Principles for Implant Design. Cambridge University Press, 2012.
Find full textConference papers on the topic "Conception de prothèse dentaire"
Baranes, M., and T. Fortin. "Planification et chirurgie guidée - Avis d’experts : Apports des nouvelles technologies en implantologie : de la planification à la réalisation de la prothèse provisoire immédiate." In 66ème Congrès de la SFCO. Les Ulis, France: EDP Sciences, 2020. http://dx.doi.org/10.1051/sfco/20206601011.
Full textElmoutawakkil, N., S. Bouzoubaa, S. Bellemkhannate, and I. Benyahya. "Flux de travail du guidage tridimensionnel en chirurgie orale." In 66ème Congrès de la SFCO. Les Ulis, France: EDP Sciences, 2020. http://dx.doi.org/10.1051/sfco/20206602005.
Full textRomanet, I., G. Maille, U. Ordioni, N. Rasmussen, and J. H. Catherine. "À propos d’un cas d’ingestion de prothèse dentaire." In 63ème Congrès de la SFCO, edited by S. Boisramé, S. Cousty, J. C. Deschaumes, V. Descroix, L. Devoize, P. Lesclous, C. Mauprivez, and T. Fortin. Les Ulis, France: EDP Sciences, 2015. http://dx.doi.org/10.1051/sfco/20156303027.
Full text