Academic literature on the topic 'Caractérisation de capteurs'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Caractérisation de capteurs.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Caractérisation de capteurs":

1

Le Maire, Pauline, and Marc Munschy. "La mesure magnétique en drone : un nouveau moyen pour cartographier à des résolutions jusque-là inaccessibles." E3S Web of Conferences 342 (2022): 02007. http://dx.doi.org/10.1051/e3sconf/202234202007.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
La méthode magnétique permet d’imager les contrastes d’aimantation de dimension centimétrique à kilométrique dans le sous-sol. Pour la bonne caractérisation de ces contrastes, il est nécessaire d’avoir une résolution suffisante (espacement entre les profils et distance entre la source et le capteur). Jusqu’à peu, les méthodes de cartographie magnétique au sol ou aéroportée ne permettaient pas l’acquisition de données dans certaines zones (Terrains accidentés, champs en culture, …). Dans ce document, nous présentons des solutions pour réaliser la mesure magnétique en drone via l’utilisation de fluxgate. La compensation du moment magnétique du drone est faite par la méthode de la calibration scalaire. Deux exemples d’applications sont présentés, l’un portant sur une campagne d’acquisition multi-échelle pour la caractérisation géologique locale. Le second porte sur de la mesure magnétique à 4 capteurs en drone et au sol.
2

Barbey, Christelle, Jérôme Helbert, Arnaud Jaën, Elodie Pagot, Jean-Charles Samalens, Lilian Valette, Christian Germain, Dominique Guyon, and Jean-Pierre Wigneron. "Complémentarité des images Pléiades et drone pour la viticulture de précision dans le cadre du programme EarthLab." Revue Française de Photogrammétrie et de Télédétection, no. 208 (October 23, 2014): 123–29. http://dx.doi.org/10.52638/rfpt.2014.128.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Une étude comparative entre des acquisitions Pléiades et par drone a été menée pour des applications de viticulture de précision dans la région Aquitaine, sur le vignoble de Buzet et deux domaines du Bordelais. Cette étude montre une bonne cohérence entre les résultats obtenus à partir des différents capteurs, à la fois pour la caractérisation des paramètres parcellaires et pour l'estimation de la vigueur de la vigne. En particulier, Pléiades met en évidence les variabilités et hétérogénéités intra-parcellaires. Pléiades est donc pertinent pour caractériser des domaines viticoles à l'échelle de l'appellation. Cependant, la résolution du satellite Pléiades limite la détection des plus petites structures à l'intérieur des rangs et empêche la caractérisation des parcelles pour lesquelles les rangs sont plus resserrés (écarts inférieurs à deux mètres). Le recours à des technologies de meilleure résolution (notamment le drone) est complémentaire afin d'obtenir des caractérisations plus précises à l'échelle d'un domaine.
3

Fade, Julien, Matthieu Boffety, and Vincent Devlaminck. "L’imagerie Polarimétrique." Photoniques, no. 109 (July 2021): 57–60. http://dx.doi.org/10.1051/photon/202110957.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Les concepts de la polarimétrie sont utilisés depuis longtemps pour la caractérisation optique des matériaux. Toutefois, l’instrumentation polarimétrique a connu son véritable essor avec l’apparition de sources artificielles contrôlées et de photodétecteurs sensibles, fournissant des outils de caractérisation très performants (ellipsomètres). Depuis trente ans, c’est au tour de l’imagerie polarimétrique de se développer avec l’apparition de systèmes de plus en plus rapides et compacts à base de composants à cristaux liquides ou, plus récemment, de capteurs d’images micro-structurés.
4

Khelifi, Cherif, and Blidi Touati. "Caractérisation d’un Distillateur à Effet de Serre." Journal of Renewable Energies 1, no. 2 (December 31, 1998): 99–108. http://dx.doi.org/10.54966/jreen.v1i2.949.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
L’analyse en régime permanent des différentes modélisations effectuées sur les capteurs solaires plans fonctionnant en basse et moyenne température a permis de développer un modèle linéaire simple susceptible d’approximer par voie expérimentale véloce les performances thermiques et optiques d’un distillateur solaire à effet de serre. Ce modèle a servi également pour l’identification du régime permanent et la vérification du temps de réponse du système dans les mêmes conditions de fonctionnement et d’environnement.
5

Dusch, Y., C. Ghouila Houri, A. Mazzamurro, G. Boussatour, H. Dahmani, O. Bou Matar, V. Maurice, P. Pernod, and A. Talbi. "Mise en oeuvre de capteurs RF-MEMS acoustiques pour l’industrie 4.0." J3eA 21 (2022): 1019. http://dx.doi.org/10.1051/j3ea/20221019.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Cette étude propose la conception complète d’un système de suivi à distance des sollicitations mécaniques dans les machines électriques afin de répondre aux problématiques de l’industrie 4.0 et de la maintenance prédictive. Elle s’appuie sur la conception, la fabrication et la caractérisation de MEMS acoustiques hautes fréquences (bande ISM à 433MHz) intégrés à un banc de test et comparés aux performances de jauges de déformation commerciales.
6

Martin, Etienne, Patrice Jardet, and Francis Pons. "Vérification et caractérisation des capteurs et des chaînes de contrôle." Revue Générale Nucléaire, no. 2 (March 1990): 110–15. http://dx.doi.org/10.1051/rgn/19902110.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Cherrington, Emil A. "BRDF-CORRECTED VEGETATION INDICES CONFIRM SEASONAL PATTERN IN GREENING OF FRENCH GUIANA’S FORESTS." Revue Française de Photogrammétrie et de Télédétection 1, no. 211-212 (December 30, 2020): 3–9. http://dx.doi.org/10.52638/rfpt.2015.536.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Parmi les outils de caractérisation de la dynamique forestière, la télédétection est particulièrement adaptée pourl’observation des vastes surfaces forestières de Guyane d’accès difficile. Dans le but de réévaluer les hypothèses énoncées dans des études antérieures sur la capacité des capteurs optiques embarqués sur les satellites à détecter la dynamique de la phénologie, nous avons compilé sur une période de 12 années divers indices de végétation corrigés des effets bi-directionnels de variation des angles d’acquisition (BRDF). Ces indices sont issus de 2 capteurs optiques: SPOT VEGETATION, et MODIS (MODerate resolution Imaging Spectroradiometer). Les données ont été analysées pour évaluer les tendances saisonnières à l'échelle de l’ensemble de la Guyane et également sur quatre sites répartis sur ce territoire. Les données révèlent que les forêts de Guyane présentent un patron de saisonnalité. Le pic annuel des divers indices au cours de la période de septembre à octobre est interprété comme le reflet d’un pic de production de feuilles pendant la saison sèche.
8

Nassar, Georges. "Capteurs acoustiques basse fréquence pour la caractérisation des milieux viscoélastiques complexes." Instrumentation Mesure Métrologie 13, no. 3-4 (December 30, 2013): 129–58. http://dx.doi.org/10.3166/i2m.13.3-4.129-158.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Camaraa, M., N. Loganathan, and A. Fischer. "Technologie additive : Impression de matériaux par jet d’encre pour l’électronique imprimée." J3eA 21 (2022): 1002. http://dx.doi.org/10.1051/j3ea/20221002.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Nous présentons un enseignement sous forme de cours, Tps et projets tutorés sur le domaine de l’impression jet d’encre de matériaux pour l’électronique imprimée (réalisation de capteurs et d’OLED (organic light-emitting diode)). Nous aborderons avec les étudiants les enjeux de l’électronique imprimée comme fabrication additive ainsi que ses caractéristiques (Encre-Tête-Substrats). A travers les projets tutorés et les travaux pratiques, nous aborderons en salle blanche la technique de dépôt de matériaux par jets d’encres : de la conception à la caractérisation des couches imprimées en passant par la réalisation : traitement pré et post impression, mesure d’épaisseur et de résistivités d’encres conductrices.
10

Rouahbi, Ch, F. Guerin, R. Tan, Ch Cappello, S. Lachaize, J. Grisolia, J. L. Noullet, et al. "Capteur de gaz à base de nanoparticules : synthèse de nano-objets par voie chimique, intégration et caractérisation de capteurs élaborés en salle blanche." J3eA 16 (2017): 1022. http://dx.doi.org/10.1051/j3ea/20171022.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Caractérisation de capteurs":

1

Proust, Julien. "Etude, caractérisation et optimisation expérimentales de nano-capteurs plasmoniques." Thesis, Troyes, 2014. http://www.theses.fr/2014TROY0001/document.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Venir sonder de faibles quantités de molécules nécessite des capteurs ultra-sensibles. Il a été démontré que les capteurs plasmoniques pouvaient remplir ce rôle. Toutefois, même après trente ans de recherches, beaucoup de questions restent sans réponses. Dans cette étude nous tentons d'y répondre : que se passe-t-il lorsqu'une molécule s'adsorbe sur la surface d'une nanoparticule ? Lorsqu'une monocouche de molécule s'adsorbe ? Et que se passe-t-il pour les molécules suivantes ? Peut-on améliorer simplement la sensibilité et la lisibilité des nano-capteurs plasmoniques? Nous démontrons expérimentalement un comportement singulier lorsque la quantité de molécules dans le champ proche des nanoparticules est très faible, typiquement de quelques zeptogrammes. Afin de mesurer cette infime quantité de matière, des solutions d'amplification des signaux sont étudiées comme l'intégration de capteurs sur des micro-lentilles axicon, ou encore sur des nano-cavités de type Fabry-Perot. Nous avons développé les micro-lentilles axicon afin de palier la faible intensité du signal émanant de nanoparticules uniques. Elles ont pour but de redistribuer le champ électromagnétique, en faisceau de Bessel de faible ouverture numérique, donc facilement mesurable. Les nano-cavités optiques ont, quant à elles, étaient développées afin de diminuer l'amortissement des résonances plasmon et ainsi affiner les résonances et augmenter la lisibilité des capteurs.Toutes ces études ont un même but : détecter in-situ les marqueurs de maladies à des concentrations infinitésimales afin de traiter les patients avant les premiers symptômes
Ultra sensitive sensors are required to probe very low concentrations of molecules. It has been shown that plasmonic nano-sensors could play this role. Nevertheless, even after thirteen years of research, a lot of questions remain unanswered.We will try to answer them in this study: what happens when a single molecule is adsorbed on a nanoparticle surface? In a monolayer? And what happens for the next layer of molecules? Can we easily enhance the sensitivity and the readability of sensors? We demonstrate experimentally a singular behavior when the quantity of molecules in the near-field region is very low, typically in the zeptogram level. To measure the low quantity of matter, different techniques to enhance the signal are studied: integration of sensor on axicon micro-lenses of Fabry-Perot like nano-cavities. We developed axicon micro-lenses to increase the intensity of unique nanoparticle signal. They redistribute the electromagnetic field into a Bessel beam with low numerical aperture, allowing an easy collection in far field. Nano-cavities have been designed to decrease the damping and refine the plasmonic resonance to increase the readability of the sensors. All these studies have the same target: to detect in-situ disease markers at very low concentrations in order to treat the patients before the first symptoms
2

Combette, Philippe. "Caractérisation d'une émulsion au moyen de capteurs ultrasonores spécifiques." Montpellier 2, 2000. http://www.theses.fr/2000MON20179.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Dans ce memoire, une application originale des capteurs ultrasonores, initialement dedies au controle non destructif, est presentee. La caracterisation d'une emulsion diphasique est ainsi realisee au moyen d'un capteur ultrasonore focalise. On definit une emulsion comme une suspension de particules d'un liquide (phase dispersee) dans un autre liquide (phase continue). On les rencontre le plus souvent dans les industries de la petrochimie, de l'agro-alimentaire et du nucleaire. L'application des capteurs ultrasonores focalises concerne les emulsions utilisees dans le retraitement nucleaire lors des operations d'extraction liquide-liquide. Le principe de la mesure s'appuie sur la reflexion des ondes ultrasonores sur la surface des gouttes constituant une partie de l'emulsion. Les echos ultrasonores reflechis permettent, apres acquisition et traitement de signal specifique, d'obtenir la vitesse ultrasonore dans la phase continue. Nous presentons, dans le premier chapitre de ce memoire, les besoins en instrumentation associes aux appareils d'extraction liquide-liquide utilises dans le domaine du retraitement nucleaire. Une modelisation des phenomenes physiques, observes lors de la reflexion des ondes ultrasonores sur la surface des gouttes, est realisee en combinant des elements de la theorie de la diffraction et de l'optique de fourier. Cette partie est abordee dans trois chapitres, le premier lie a l'interaction ondes acoustiques planes et objets spheriques, le second portant sur la modelisation de la reponse d'un capteur focalise analysant un objet spherique et le troisieme presentant une validation experimentale des modeles. Une optimisation du capteur permet d'obtenir des informations complementaires sur la phase continue. Les applications de cette methode de caracterisation sont realisees sur des appareils d'extraction et sont presentees dans le dernier chapitre.
3

Rougeau, Laurent. "Synthèse et caractérisation de composés thermochromes. : Application aux capteurs thermiques." Chambéry, 2006. http://www.theses.fr/2006CHAMS027.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
L’objectif de ce travail est la création d'une étiquette intelligente permettant de visualiser, grâce à un changement de couleur, si le produit auquel elle est rattachée a été exposé à une température supérieure à un seuil défini. Nous nous sommes intéressés aux composés diacétyléniques qui ont un faible coût de revient et offrent la possibilité d'obtenir un grand nombre de structures différentes. Au-delà de l'objectif industriel, cette thèse aborde différentes études supplémentaires. Pour comprendre le phénomène de la thermochromie, nous avons déterminé la structure des différents composés avant et après changement de couleur au moyen de techniques analytiques: RMN du solide, spectrométrie Raman, RPE, Rayons X. Nous avons également établi des relations structure/propriété entre les diynes de départ et leurs propriétés thermochromes, notamment l'influence des longueurs de chaînes et la présence de certaines fonctions. Nous avons identifié une nouvelle famille de composés diacétyléniques thermochromes (monoester) virant du bleu (après irradiation UV) au rouge (après chauffage) à des températures variant de -20 à +75°C en fonction de la longueur de la chaîne. L'intermédiaire bleu réagit très rapidement à divers stimuli et le composé rouge est insoluble, ce qui a limité le champ des techniques d'analyses disponibles. Néanmoins, les différentes analyses du solide ont permis de proposer une structure pour chaque intermédiaire et un mécanisme pour le comportement thermochrome. Lors de l'irradiation UV, on passe d'un système diacétylénique conjugué à un cumulène ayant des radicaux libres à ses extrémités, puis après chauffage on forme un polymère hyperconjugué constitué d'un enchaînement de doubles et triples liaisons. Enfin, une étude par Rayons X a permis de comprendre pourquoi certains composés étaient thermochromes alors que d'autres ne l'étaient pas, la structure cristalline du composé de départ, jouant un rôle très important dans le phénomène thermochrome
The target of this work is to create an intelligent label able to indicate if temperature has risen over a definite threshold. This control is highlighted by colour change. To meet industrial requirements (one or tow-step syntheses from low cost starting materials), we have studied diacetylenic compounds which can provide a great number of various molecules. Beyond industrial objective, this thesis approaches additional studies. To understand the thermochromic phenomenon, we have determined the structure of various compounds before and after the colour change by analytical techniques: solid NMR, Raman spectrometry, ESR, X-rays. We have also established structure/property relationships between the starting diyns and their thermochromic properties, especially influence of chains lengths and chemical functions (alcohol, ester, ether, amine, amide. . . ). We have identified a new family of thermochromic diacetylenic compounds (asymmetric monoesters) changing from blue (after UV irradiation) to red (after heating) at temperatures varying from -20 to +75°C according to the chains length. The blue intermediary product reacts very quickly to various stimuli and the red compound is insoluble, which has limited the field of usable analytical techniques. Nevertheless, various solid analyses have allowed us to propose a structure for blue and red compounds and a mechanism for the thermochromic behaviour. During UV irradiation, the diacetylenic conjugated system is transformed into a cumulene having free radical to its ends, then after heat we obtain a hyperconjugated polymer with double and triple bounds. Lastly, an X-rays study has allowed us to understand why some compounds turn red whereas others not, crystalline structure of the starting compound playing a very important role in thermochromic phenomenon
4

Megriche, Adel. "Elaboration et caractérisation de matériaux piézoélectriques pour capteurs haute température." Lyon, INSA, 1999. http://www.theses.fr/1999ISAL0022.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
La finalité industrielle et technologique des matériaux piézoélectriques pour capteur haute température impose : *une température de Curie Tc élevée (>500 °C) * une résistivité électrique élevée ( > 107cm à Température >Tc/2) * une bonne stabilité des propriétés piézoélectriques et diélectriques avec la température. Les matériaux ferroélectriques de type niobate de lithium (Tc = 1210 °C) et les titanates de bismuth à structure pérovskite en couches ( Tc > 550 °C) sont des candidats potentiels pour ce genre d' appiication, car ces matériaux présentent des températures de Curie suffisamment élevées pour pouvoir conserver des propriétés piézoélectriques jusqu'à 500 oc. L'influence de substitutions et d'un dopage en masse sur ces matériaux a été étudiée. Nous obtenons ainsi une amélioration des propriétés piézoélectriques et des caractéristiques électriques tout en conservant une bonne stabilité en température et une température de Curie élevée. Trois formulations ont par suite été retenues pour lesquelles une caractérisation tensorielle complète a été donnée: • Li0. 97Na0,03NbO3 + 0. 2% MnO2 • Bi4Ti2,95W0,05O12 + 0. 2%Cr203 • Na0,5La0,5Bi4Ti3,85Nb0,15O15 + 0. 3% MnO2. Un premier prototype de capteur est réalisé par le collage d'une céramique sur une feuille métallique formant ainsi un bimorphe travaillant en flexion. Les mesures en température montrent une limite de ce prototype vers 300 °c due au décollement céramique - métal. Pour contourner ce problème, une alternative intéressante a été la réalisation d'un capteur par le dépôt par sérigraphie d'un film épais de matériau actif sur un substrat en alumine. Sa stabilité en température a été confirmée jusqu'à 450°C
The need for high temperature piezoelectric material sin, for example, ultrasonic probes and pressure sensors is very important for automobile industry or chemical transformations. At present, only single crystals of tourmaline, which has poor piezoelectric coefficients can be operated above 600 °c. The objective of this work is to develop a piezoelectric ceramics with improved properties, which can be operated up to 500 °c. Two families of materials with Curie temperature above 600 °c have been selected, namely LiNbO3 and a Bismuth Titanates belongs to the Aurivillius compounds family that can be represented by the general formula Bi2An-1BnO3n+3 in which A can be a monovalent, divalent or trivalent cation or a mixture of them, B represents Ti 4 +, Nb5+, W6+ etc. , and n can have values of 2,3,4. . . Preparation of dense ceramics with the required properties will be achieved with varied substitutions and some additives impurities. Tree compositions are chosen and caracterized in high temperature device. -* Li0,97Na0,03NbO3+0,2% MnO2 -* Bi4Ti2?95W0,05O12+0,2%Cr2O3 -* Na0,5Bi4Ti3,85N0,15O15+0,3%MnO2. At the same time a two high temperature acoustic pressure sensors will be developed for use with the piezoelectric ceramics and thick films. The response of the realized sensor to an acoustical load is analysed in relation to temperature
5

Daulle, Armelle. "Conception, réalisation et caractérisation de capteurs de puissance micro-onde." Université Joseph Fourier (Grenoble), 1999. http://www.theses.fr/1999GRE10167.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Le travail presente dans ce memoire se compose de deux etudes realisees conjointement et de facon complementaire. La premiere concerne la conception et la caracterisation de deux capteurs de puissance micro-onde dont le fonctionnement est base sur la conversion de l'energie haute frequence en chaleur. L'un, destine a des mesures rapides de signaux de telecommunications, met a profit la grande sensibilite thermometrique des couches minces de nitrure de niobium. La mesure de la puissance se fait selon un principe de compensation. Un temps de reponse de 2 s, tres competitif vis a vis des capteurs a diodes, a ete obtenu dans la gamme de puissance + 10 dbm ; +28 dbm et a des frequences de l'ordre du gigahertz. L'autre, destine a des mesures de puissances moyennes, utilise un element sensible realise en couche mince metallique taperisee. Son principe de fonctionnement n'a, a notre connaissance, jamais ete experimente pour la mesure de puissance micro-onde dans les structures planaires. Ces capteurs ont pour point commun le couplage electromagnetique/thermique, qui peut generer non-linearites, points chauds, regimes transitoires rapides et derives thermiques lentes. Dans le but de detecter ces phenomenes simultanes mais d'echelles tres differentes, nous avons developpe un outil de modelisation numerique par ondelettes, utilisant la methode de galerkin en deux dimensions. La seconde partie de ce memoire est consacree a la description des differentes versions de notre algorithme et de sa mise en uvre numerique. Developpe, teste et mis au point sur un cas fictif d'electromagnetisme, le programme a ensuite ete adapte a la resolution de deux problemes thermiques relatifs a nos capteurs.
6

Dhahbi, Hakim. "Caractérisation et modélisation de matériaux magnétiques pour capteurs de courant." Thesis, Université Grenoble Alpes (ComUE), 2018. http://www.theses.fr/2018GREAT027/document.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Le sujet concerne l’étude de capteurs d’alimentation utilisés dans les disjoncteurs de Schneider Electric qui doivent fonctionner de plus en plus à fréquences variables. On s’intéresse notamment aux « pertes fer », en s’appuyant sur leur caractérisation et leur modélisation. L’étude s’appuie sur l’amélioration du modèle LS dans le but de son intégration dans le dimensionnement du capteur. Le modèle est intégré en post traitement sur Flux®, une application en temps réel a donc été développée afin d’intégrer les pertes dans la simulation du capteur et de son environnement. Une analyse expérimentale du comportement du circuit magnétique du capteur a aussi été entreprise d’une part en intégrant de nouveaux matériaux et d’autre part en tenant compte des procédés de fabrications et des conditions de fonctionnement du capteur. Aussi une étude calorimétrique a été menée afin de mesurer les pertes fer du capteur expérimentalement et de mettre en place des mesures références à comparer avec les résultats de simulations. Enfin, deux missions principales ont été entreprises et restent à finaliser : une nouvelle méthode du modèle LS statique et un dispositif expérimental, un calorimètre, a été conçu et testé mais des améliorations restent à réaliser
The topic of this study involves power sensors used in Schneider Electrics circuit breakers that should operate increasingly at variable frequencies. We are particularly focusing on "iron losses” through their characterization and modelling. The study is based on the improvement of the LS model in order to use it in the dimensioning of the sensor. The model is integrated in Flux® as post-processing; therefore an application has been developed that includes Ls model iron losses at each time step in the simulation of the sensor and its environment. An experimental analysis of the behaviour of the sensors magnetic circuit was also conducted by integrating new materials on the one hand and by considering the manufacturing processes and operating conditions of the sensor on the other hand. Furthermore, a calorimetric study was conducted to measure the iron losses of the sensor experimentally and to state reference measurements to compare with the results of simulations. Finally, two main missions have been engaged and remain to be finalized: a new method of the static LS model and an experimental bench, a calorimeter, has been designed and tested, but still to be improved
7

Pham, Q. Nghi. "Elaboration et caractérisation d'oxydes perovskites pour capteurs de pH - Etude du mécanisme de fonctionnement de ces capteurs." Phd thesis, Université du Maine, 2006. http://tel.archives-ouvertes.fr/tel-00417172.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Pham, Quoc Nghi. "Elaboration et caractérisation d'oxydes perovskites pour capteurs de pH : étude du mécanisme de fonctionnement de ces capteurs." Le Mans, 2006. http://cyberdoc.univ-lemans.fr/theses/2006/2006LEMA1002.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Les oxydes conducteurs de structure perovskite peuvent être utilisés en tant qu'élément sensible dans des capteurs de pH. Une conductivité ionique élevée et une grande résistance chimique et mécanique sont des atouts majeurs qui leur confèrent des temps de réponse courts et des utilisations potentielles dans l’industrie, agroalimentaire, en particulier. En premier lieu, la structure cristallographique et les propriétés de conduction de différents composés ont été étudiées avant de tester leur sensibilité au pH. Les conditions optimales de la fabrication d'une membrane céramique sensible à partir des poudres synthétisées par différentes méthodes ont été déterminées. De plus, les caractéristiques principales du capteur céramique ont été déterminées: sensibilité temps de réponse, sélectivité, influence des espèces rédox… Parmi les oxydes étudiés, le composé Li0. 30La0. 57TiO3 (LLTO) présentant la plus grande sensibilité au pH, a été choisi comme matériau modèle pour l’étude du mécanisme de détection du pH. Différents mécanismes ont été envisagés: l'oxydo-réduction, l'échange ionique et la réaction des groupes -OH en surface d'oxyde. Des résultats expérimentaux montrent que parmi ceux-ci, les groupes -OH en surface d'oxyde sont à l’origine des propriétés acido-basiques des membranes céramiques. La propriété de détection du pH par un capteur potentiométrique de ce type est unique et innovante. Ce travail permettra d’aborder la phase de valorisation de ces capteurs de pH
Perovskite oxides can be used as sensitive element in pH sensors. A high ionic conductivity, mechanical and chemical resistances allow a fast response time and some potential applications in industry, such as food industry. Firstly, the crystallographic structure and the conduction properties of various oxides were studied before testing their pH sensitivity. Secondly, the optimized conditions to obtain a ceramic sensitive membrane starting from powders synthesized by various methods were determined. Moreover, the characteristics of the pH sensor were determined: response time, selectivity, influence of the redox species… Finally, among the studied compounds, the Li0. 30La0. 57TiO3 (LLTO) compound which exhibits the highest sensitivity to the pH was selected as model for studying the mechanism of pH detection. In particular, there mechanisms were suggested: the oxydo-reduction, the ionic exchange and the reaction of the -OH groups at the oxide surface. Experimental results show that the -OH groups at the oxide surface are responsible of the pH sensitivity of the ceramic membranes. The pH detection property by a potentiometric sensor of this type is unique and innovative. This work will allow the development of these pH sensors for practical uses
9

Gaborit, Gwenaël. "Caractérisation de champs électriques hyperfréquences par capteurs électro-optiques vectoriels fibrés." Chambéry, 2005. http://www.theses.fr/2005CHAMS039.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
Les champs électriques hyperfréquences guidés ou rayonnés sont couramment caractérisés avec des sondes métalliques ou des antennes. Ces techniques de mesures présentent d'importantes limitations : une bande de fréquence relativement étroite, une faible résolution spatiale et une perturbation significative du signal à mesurer. Les capteurs électro-optiques (EO) fibrés développés dans cette thèse sont complètement diélectriques, minimisant ainsi la perturbation induite sur la mesure. Ils sont basés sur l'effet Pockels, lequel consiste en une modification des indices de réfraction d'un cristal EO induite par un champ électrique. Nous avons utilisé la modulation d'état de polarisation et d'amplitude induite par le champ sur un faisceau laser pour exploiter cet effet. La résolution spatiale transverse de ces capteurs dépend de la forme du faisceau à l'intérieur du cristal et peut atteindre 10 mm. La sélectivité aux composantes du champ est directement liée aux modifications des axes diélectriques propres du cristal. Alors qu'un cristal anisotrope (LiTaO3 ou DAST) a permis de mesurer vectoriellement une composante du champ électrique avec une sélectivité supérieure à 46 dB, un cristal isotrope (ZnTe) a permis une caractérisation simultanée des deux composantes du champ avec un seul cristal et un seul faisceau sonde. Nous avons ainsi validé les avantages inhérents à la caractérisation de champs électriques hyperfréquences par capteur EO comparativement aux techniques telles que les antennes, les bolomètres, la thermographie infrarouge,. .
Microwave guided or radiated electric (E) fields are usually characterized using metallic probes or dipole antennas. This kind of measurement presents important limitations: a relatively narrow frequency bandwidth, a quite low spatial resolution and a significant disturbance of the signal to be measured. In this PhD Thesis, the developed pigtailed electro-optic (EO) sensors are fully dielectric, thug minimizing the perturbation induced on the signal to be measured. They are based on the Pockels' effect which consists in a modification of the refractive indices of an EO crystal induced by an applied E field. Finally, we have used two types of modulation in order to exploit the Pockels' effect : our pigtailed EO sensors are either based on polarization state modulation or on amplitude modulation. Their transversal spatial resolution depends on the shape of the laser beam inside the EO crystal and can be of the order of 10 j1,m. The selectivity to E field components is directly linked to the modification of the eigen dielectric axis of the EO crystal induced by the applied E field. While anisotropic crystals (e. G. LiTaO3 or DAST) allow us to measure one component of the E field (a selectivity of 46 dB has been reached), isotropic crystals (ZnTe) provide a simultaneous two-components E-field measurement using a single crystal and a single laser probe. We have demonstrated the advantages of E-field measurements using EO sensors compared to other techniques like antennas, bolometers, infrared thermography,. .
10

Drean, Emilie. "Contribution au développement de capteurs piézoélectriques pour la caractérisation mécanique des étoffes." Mulhouse, 2006. http://www.theses.fr/2006MULH0853.

Full text
APA, Harvard, Vancouver, ISO, and other styles
Abstract:
L'objectif de l'étude est la mise au point d'un capteur intégrable dans une étoffe de revêtement de siège, dans le but de mesurer la masse d'un passager. Ce type d'étoffe est constitué de plusieurs couches, ce qui facilite l'intégration d'un capteur. Le choix s'est porté sur des capteurs piézoélectriques à base de PVDF. 20 étoffes ont été caractérisées en compression à l'aide de la chaîne de mesure Kawabata. Leur comportement est dépendant de celui de la mousse. La méthode de mesure consiste en l'analyse de la réponse sous contrainte de compression d'un disque de PVDF en utilisant sa fréquence de résonance. Le paramètre étudié est la phase, elle varie linéairement avec la contrainte. Les pentes des droites diffèrent selon l'étoffe étudiée ; elles sont corrélées avec les caractéristiques en compression. Pour l'application automobile, des essais en cas réel ont été menés après analyse des paramètres extérieurs. La phase varie linéairement avec la masse en position assise des sujets.

Book chapters on the topic "Caractérisation de capteurs":

1

Masilamany, Gayathri, Pierre-Yves Joubert, Stéphane Serfaty, Yohan Le Diraison, and Magdalena Couty. "Capteurs inductifs radiofréquences pour la caractérisation diélectrique de tissus biologiques." In Instrumentation et Interdisciplinarité, 157–62. EDP Sciences, 2020. http://dx.doi.org/10.1051/978-2-7598-1206-6-019.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Masilamany, Gayathri, Pierre-Yves Joubert, Stéphane Serfaty, Yohan Le Diraison, and Magdalena Couty. "Capteurs inductifs radiofréquences pour la caractérisation diélectrique de tissus biologiques." In Instrumentation et Interdisciplinarité, 157–62. EDP Sciences, 2020. http://dx.doi.org/10.1051/978-2-7598-1206-6.c019.

Full text
APA, Harvard, Vancouver, ISO, and other styles

To the bibliography