Dissertations / Theses on the topic 'BTEA'

To see the other types of publications on this topic, follow the link: BTEA.

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'BTEA.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Fjordestam, Patrik, and Sebastian Hansen. "Control and monitoring of a BTES-system." Thesis, Högskolan i Halmstad, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-30207.

Full text
Abstract:
During the summer excess energy is produced from solar heaters, this is not taken care of, and usually goes to waste. The base of the project is built on that you should take the excess energy during the warmest months of the summer and save the energy in boreholes in the ground, then during the colder months the energy can be used. The purpose of the project was to build a prototype for the control and monitoring of a system. With this project we want to present a solution to a prototype which can be used as a development platform for the client. Communication between the actuators, sensors and the controller is made via a CAN-bus. The temperature sensors uses a One-wire buss and its values are stored and can be shown on a website. The results show that the monitoring and control functions works. Theoretically, the prototype is designed to be expanded to a real application.
Under sommaren produceras överbliven energi från solvärmare, denna tas inte omhand utan går oftast till spillo. Projektets grund bygger på att ta den överblivna energin under de varmaste månaderna på sommaren och spara undan energin i borrhål i marken, för att sedan under kallare månader kunna använda detta. Syftet med projektet har varit att bygga en prototyp för styrning och övervakning av ett system. Med detta projekt vill vi visa en lösning på en prototyp som kan fungera som utvecklingsplattform för beställaren. Kommunikation mellan aktuatorer, sensorer och styrenhet görs via en CAN-buss. Temperaturensorernas använder sig av en One-wire buss och dess värden sparas och kan avläsas på en webbplats. Resultatet visar att övervakning av sensordata och reglering av aktuatorer fungerar. Teoretiskt sett är prototypen utformad för att expanderas till en verklig applikation.
APA, Harvard, Vancouver, ISO, and other styles
2

Valentin, Leonardo Antonio. "\"Boas práticas de laboratório: aplicação para avaliar o impacto ambiental causado pelo derrame de derivados de petróleo\"." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/75/75132/tde-11042007-104414/.

Full text
Abstract:
O meio ambiente vem sofrendo diariamente com problemas relacionados a vazamentos, derramamentos e acidentes durante a exploração, refinamento, transporte, e operações de armazenamento de petróleo e seus derivados. Em um derramamento e/ou vazamento de combustível, uma das principais preocupações é a contaminação dos aqüíferos que são usados como fonte de abastecimento de água para consumo humano. As preocupações relacionadas ao potencial de contaminação de água subterrânea vem crescendo em todo o Brasil, já que a maioria dos postos possui mais de dez anos. Com isso, este estudo tem como objetivo contribuir na segurança, confiabilidade e qualidade nas determinações de contaminantes (BTEX e HPAs) em solo e água provenientes de derrames de derivados de petróleo. Para isso, foram aplicadas metodologias analíticas para determinação destes compostos tomando como base os métodos da EPA. Com relação a segurança e confiabilidade nos resultados, foi proposto a aplicação das BPL nos tópicos que possuem relação com o tema. Foi indicado, segundo a literatura, um método de descontaminação das sobras de amostragem que pode ser incluído na rotina de trabalho dos laboratórios.
The environment is suffering daily with problems related to leaks, spillings and accidents during the exploration, refinement, transport and operations of storage of petroleum and yours derived. In a spilling and/or leak of fuel, one of the main concerns is the contamination of the watery ones that are used as source of water supply for human consumption. The concerns related to the potential of contamination of underground water are growing throughout Brazil, since most of the gas stations possesses more than ten years. With that, this study has as objective contributes in the safety, reliability and quality in the determinations of pollutants (BTEX and PAHs) in soil and water coming of hemorrhages of derived of petroleum. For that, they were applied analytical methodologies for the determination of these pollutants taking as base the methods of EPA. Regarding safety and reliability in the results, the application of GLP was proposed in the topics that possess relationship with the theme. It was indicated, according to the literature, a method of treatment of the polluted sampling surpluses, that it can be included in the routine of work of the laboratories.
APA, Harvard, Vancouver, ISO, and other styles
3

Anderson, Cody Allen. "Permeation Sampling of BTEX and Gasoline." University of Akron / OhioLINK, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=akron1279115371.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Oliveira, Luciana de. "Avaliação da capacidade de biodegradação de benzeno, tolueno, etilbenzeno e isômeros de xileno por bactérias isoladas de área contaminada." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/42/42132/tde-02022018-160943/.

Full text
Abstract:
Os compostos BTEX (benzeno, tolueno, etilbenzeno e xilenos) são os contaminantes mais frequentemente encontrados dentre os hidrocarbonetos de petróleo. A remoção destes compostos é dependente da atividade de uma população de micro-organismos adaptados capazes de promover a biodegradação dos mesmos. Neste estudo, foram utilizadas cinco cepas isoladas de área contaminada capazes de degradar estes compostos. As concentrações de BTEX foram determinadas por análises quantitativas realizadas por cromatografia gasosa com extração por headspace. Uma série de experimentos foi realizada para investigar a capacidade destas cepas de remover os compostos BTEX de forma individual e simultânea. Os ensaios de indução de vias metabólicas mostraram que cada um dos BTEX foi capaz de induzir as vias de degradação de todos os quatro substratos, resultado que foi visualizado a partir do crescimento das cepas em cada um dos BTEX após as mesmas terem sido ambientadas em apenas um deles. Para os ensaios de degradação, Os resultados revelaram que as cinco cepas foram capazes de degradar todos os BTEX, tanto na forma de um único substrato bem como em forma de mistura. As taxas de remoção de um único substrato ficaram entre 63,9% e 97,9%. Houve um aumento da degradação dos compostos quando os mesmo foram fornecidos em forma de mistura. Com exceção do benzeno, todos os compostos foram degradados até atingirem concentrações que ficaram abaixo do limite de potabilidade estipulados, dentro de 9 horas.
BTEX (benzene, toluene, ethylbenzene and xylenes) compounds are the most frequently encountered subsurface contaminants among the various petroleum hydrocarbons. Removal of these compounds is dependent on the activity of a population of microorganisms adapted to promote biodegradation of them. In this study, five strains isolated from contaminated groundwater .able to degrade BTEX compounds were used. BTEX concentrations were determined by quantitative analysis performed by gaseous chromatography with headspace extraction. A series of batch experiments were carried out to investigate the ability of the strains for removing BTEX compounds using single and mixed substrates. The pathway induction assays showed that each one of the BTEX compounds was able to induce the degradation pathways of all four substrates, result that was visualized from the growth of the strains in each of the BTEX after they had been set in only one of them. For the degradation assays, the results revealed that the five strains were able to degrade all BTEX, both in the form of a single substrate as well as in the form of a mixture. The rates of removal of a single substrate were between 63.9% and 97.9%. There was an increased degradation of the compounds when they were provided as a mixture. With the exception of benzene, all compounds were degraded to concentrations below the stipulated drinking limit within 9 hours.
APA, Harvard, Vancouver, ISO, and other styles
5

Laurentino, Lauro de Sena. "Avaliação da poluição sonora e dos teores de BTEX em kartódromos da cidade do Rio de Janeiro." Universidade do Estado do Rio de Janeiro, 2010. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=2829.

Full text
Abstract:
Este trabalho teve como objetivo o monitoramento ambiental incluindo, a avaliação da temperatura ambiente, umidade relativa, ruído e qualidade do ar de kartódromos indoor e outdoor, localizados na cidade do Rio de Janeiro. A qualidade do ar foi monitorada através da determinação dos teores de benzeno, tolueno, etil-benzeno e xilenos, conhecidos como BTEX. Esses compostos apresentam alta toxicidade e se encontrados acima dos limites permitidos, podem prejudicar a saúde dos usuários e principalmente dos funcionários do estabelecimento. Para a realização da quantificação dos BTEX no ar, foi utilizada a técnica de amostragem ativa, seguida de extração por solvente e posterior análise por Cromatografia Gasosa com detecção por espectrometria de massas. O nível do ruído também foi um parâmetro estudado e comparado com a legislação vigente. Sabe-se que, principalmente em longo prazo, a exposição a níveis elevados de ruído prejudicam a audição e em alguns casos (normalmente os ocupacionais) sua perda total ou parcial. O equipamento utilizado para a medição foi um decibilímetro. Os resultados do kartódromo indoor, do outdoor e do estacionamento sem nenhuma atividade de kart foram analisados e comparados entre si
APA, Harvard, Vancouver, ISO, and other styles
6

Lima, Kassio Michell Gomes de. "Sensores opticos e instrumentação para determinação de contaminantes em aguas." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/250562.

Full text
Abstract:
Orientadores: Ivo Milton Raimundo Junior, Maria Fernanda D'Oliveira Pimentel
Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica
Made available in DSpace on 2018-08-13T12:57:52Z (GMT). No. of bitstreams: 1 Lima_KassioMichellGomesde_D.pdf: 3376040 bytes, checksum: c43fc17e739fb3c24ee4fa1b849c70ef (MD5) Previous issue date: 2009
Resumo: Este trabalho descreve o desenvolvimento de sensores ópticos para determinação de benzeno, tolueno, etilbenzeno e xilenos (BTEX) e de íons metálicos em águas. Para a determinação de BTEX, monolitos de polidimetilsiloxano (PDMS) foram colocados dentro de um frasco preenchido com soluções aquosas dos compostos BTEX por um determinado tempo. Em seguida, a fase sensora era removida da solução, seca rapidamente e inserida num sistema de medidas, empregando-se um espectrofotômetro FT-NIR. Limites de detecção de 0,079; 0,12; 0,14 e 0,28 mg L para benzeno, tolueno, etilbenzeno e xilenos foram alcançados. A fase sensora foi aplicada a amostras de águas contaminadas por gasolina, quantificando teores de BT (benzeno e tolueno) sem diferença estatística, no nível de 95% de confiança, comparada a técnica GC-FID. A fase sensora também foi usada na determinação simultânea de BTX. Valores de RMSEP (raiz quadrada do erro médio quadrático de previsão) de 0,57 mg L para benzeno, 2,21 mg L para tolueno e 1,23 mg L para xilenos foram alcançados. Um fotômetro no infravermelho próximo baseado em LED (diodos emissores de luz) para a determinação de BTEX total foi desenvolvido. O instrumento desenvolvido opera com dois LED, um fotodiodo, um sistema de fibras ópticas para captação da radiação, célula de transmissão e um programa em Visualbasic.Net para controle e aquisição de dados. O instrumento pode ser uma alternativa viável, de baixo custo para a determinação de BTEX total em águas. Foi avaliado o comportamento do novo reagente luminescente di(hexafluorofosfato) de bis(1,10-fenantrolina)(2-(1H-imidazo[4,5- f][1,10]fenantrolina)Rutenio (II), abreviadamente [Ru(phen)2iip](PF6)2, no desenvolvimento de um sensor óptico para a determinação de íons metálicos em águas. A imobilização do reagente em matrizes poliméricas revelou que o sensor óptico e seletivo ao íon Cu(II), apresentando limite de detecção 32 mg L. O novo complexo de rutênio (II) foi aplicado numa determinação simultânea dos íons metálicos Cu(II) e Hg(II) em solução aquosa, alcançando valores de RMSEP de 2,12 mg L e 0,95 mg L, respectivamente
Abstract: This work describes the development of optical sensors for determination of benzene, toluene, ethylbenzene and xylenes (BTEX) and metal ions in water. For the determination of BTEX, monoliths of polydimethylsiloxane (PDMS) were inserted into a bottle filled with aqueous solutions of BTEX compounds for a pre-defined period of time. Afterwards the sensing phase was removed from the solution, dried and placed in the detection system of an FT-NIR spectrophotometer. Detection limits of 0.079, 0.12, 0.14 and 0.28 mg L for benzene, toluene, ethylbenzene and xylenes, respectively, have been achieved. The sensing phase was applied to the determination of benzene and toluene in water samples contaminated by gasoline, providing results that did not show statistical differences from those obtained by GC-FID at a confidence level of 95%. The sensing phase was also applied to the simultaneous determination of BTX in contaminated water, providing RMSEP values (root mean square error of prediction) of 0.57 mg L for benzene, 2.21 mg L for toluene and 1.23 mg L for xylenes. A near infrared photometer based on LED (light emitting diodes) for the determination of total BTEX was developed. The instrument operates with two LED as light sources and a photodiode as detector, a transmission cell connected to an optical fiber bundles; a VisualBasic.Net program was written for control and data acquisition. The instrument performance indicated that it can be a feasible and low cost alternative for the determination of total BTEX in water. Finally, it was evaluated the performance of the new luminescent reagent bis(1,10-phenanthroline)(2-(1H-imidazol-2- yl)-1H-imidazo[4,5-f][1,10]phenanthroline)ruthenium(II) di(hexafluorophosphate) for the development of an optical sensor for the determination of metal ions in water. The immobilization the reagent in the polymeric matrices showed that the optical sensor is selective to Cu (II) ion, providing a detection limit of 32 mg L. The new complex of ruthenium (II) was also applied to the simultaneous determination of Cu (II) and Hg (II) in aqueous solution, showing RMSEP values 2.12 mg L and 0.95 mg L, respectively
Doutorado
Quimica Analitica
Doutor em Ciências
APA, Harvard, Vancouver, ISO, and other styles
7

Souza, Renata dos Santos 1982. "Avaliação da lama vermelha na remoção de derivados de petróleo - benzeno, tolueno e xileno (BTX)." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/266619.

Full text
Abstract:
Orientador: Meuris Gurgel Carlos da Silva
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química
Made available in DSpace on 2018-08-22T16:47:28Z (GMT). No. of bitstreams: 1 Souza_RenatadosSantos_D.pdf: 2889400 bytes, checksum: 692c0c9b405b4f550e07f530c56c124c (MD5) Previous issue date: 2013
Resumo: Muitos compostos orgânicos derivados do petróleo são encontrados na água subterrânea, oriundos de processos industriais ou, principalmente, dos vazamentos de combustível em postos de distribuição. Dentre esses compostos encontram-se benzeno, tolueno e xileno (BTX), substâncias tóxicas e carcinogênicas e que se constituem nos componentes mais poluidores da gasolina. Processos de remoção dos BTX devem atender aos limites da legislação e, nesse sentido, a adsorção é um dos métodos mais eficientes. Neste trabalho foi proposto avaliar a lama vermelha, resíduo da indústria de beneficiamento do alumínio, nas formas bruta, calcinada e quimicamente tratada, como material adsorvente alternativo para remoção dos BTX em soluções sintéticas com um e dois adsorbatos. A caracterização da lama vermelha indicou que o material é macroporoso, muito heterogêneo e constituído de uma mistura de óxidos principalmente sodalita, hematita, goetita, gibbsita e quartzo. A calcinação provocou alterações na estrutura do adsorvente, aumentando a área superficial e a quantidade e tamanho de macroporos. O estudo do pHzpc mostrou que o pH natural da lama vermelha tornou a superfície carregada negativamente, atraindo assim o anel benzênico e melhorando a adsorção. Os ensaios de cinética de adsorção mostraram um processo rápido com no máximo 2h para atingir o equilíbrio e o percentual de remoção foi acima de 85% para todos os compostos. Nos ensaios de equilíbrio com monocomposto a ordem decrescente de adsorção foi benzeno, tolueno e xileno. As maiores capacidades de adsorção de benzeno foram qe = 0,332 mmol/g com lama bruta, e com lama calcinada qe = 0,335 mmol/g, esses valores são elevados quando comparados com adsorventes do tipo argilominerais. Os modelos Langmuir com dois sítios e múltiplos espaços de adsorção foram os que melhor se ajustaram aos resultados experimentais de adsorção com monocomposto, porém não conseguiram prever as multicamadas existentes nas isotermas. Foi verificada uma diminuição na remoção de todos os BTX na condição de mistura binária. A ordem de remoção de BTX foi inversa e com maiores remoções de xileno (qe = 0,3406 mmol/g). O modelo de Langmuir se ajustou adequadamente aos resultados experimentais, nessa condição
Abstract: Many organic compounds derived from oil are found in groundwater from industrial processes or specially from leaks at fuel tanks in gas stations. Among these compounds are benzene, toluene and xylene (BTX), toxic and carcinogenic substances that are the most polluters compounds from gasoline. BTX removal processes must attend to legislation limits and thus the adsorption process is one of the most efficient methods. In this work it was used red mud, an aluminum industry waste, in the raw, calcined forms and chemically treated forms, as an alternative adsorbent, to remove the BTX from single and two-component aqueous solutions. The characterization of the red mud indicated that this material is macroporous, very heterogeneous and compound from an oxides mixture, mainly sodalite, hematite, goethite, gibbsite and quartz. The calcination caused changes in the adsorbent structure, increasing the superficial area and the macroporous quantities and size. The pHpzc study showed that the natural red mud pH lets the surface negatively charged, attracting then the benzene rings and improving the adsorption. The kinetic adsorption showed a fast process that needs 2 h to achieve the equilibrium and a removal percentage of 85% for all compounds. In the single component equilibrium studies the adsorption order was benzene, toluene e xylene. The maximum adsorption capacities were qe = 0,332 mmol/g on raw red mud (RM), and on calcined red mud (CRM), qe = 0,335 mmol/g. DSL and MSAM models were the best fit to the experimental data in the single component adsorption, although they could not to predict the multiple layers existing in the isotherms. It was verified a decrease in the removal of all BTX in the two-component adsorption. There was a change in the BTX removal order and more removal of xylene (qe = 0,3406 mmol/g). The Langmuir model showed good fit to the experimental data in this condition
Doutorado
Engenharia de Processos
Doutora em Engenharia Quimica
APA, Harvard, Vancouver, ISO, and other styles
8

Persson, Jesper, and Kristoffer Dahl. "Control and Monitoring of a BTES-System." Thesis, Högskolan i Halmstad, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-30304.

Full text
Abstract:
Termisk energi som solfångare producerar kan lagras i Borehole Thermal Energy Storage, BTES, när efterfrågan är låg, för att sedan användas när efterfrågan är hög. Målet med detta examensarbete är att utveckla en skalbar systemarkitektur för styrning och monitorering av en BTES prototyp, där ringarna som borrhålen utgör är indelade i olika temperaturhierarkier. De ringar som ligger närmare centrum av borrhålen har högre temperaturhierarki än de som ligger längre ut. Driftinformation från systemet ska kunna följas på en webbplats och temperaturdata från systemet ska sparas undan för lagring. Datakommunikationen består av en One-Wire buss som innehåller temperatursensorer och ett CAN-buss system för datakommunikation mellan sensor/aktuator-noder och server-nod. Utifrån sensordata bestäms reglering av ventiler. Driftinformation lagras i en databas och från denna databas presenteras informationen på en hemsida. Hemsidan innehåller en överblick av brunnparken där temperaturen i varje brunn kan utläsas. Regleralgoritmen uppfyller den sökta temperaturhierarkin där de högsta temperaturerna ska vara i centrum av brunnparken. Prototypen fungerar som en utvecklingsplattform och demonstrerande prototyp.
Thermal energy produced from solar collectors can be stored in Borehole Thermal Energy Storage, BTES, when demand is low for later usage when demand is high. The aim of this thesis is to develop a scalable system architecture for control and monitoring of a BTES prototype.The BTES prototype consist of 13 boreholes configured in a hierarchically manner in two circles and one core. The core is of the highest priority. The operational information is displayed on a website and stored in a database.The data communication consist of two One-wire buses and one CAN bus. The temperature sensors are connected to the One-Wire buses. The CAN bus consist of sensor/actuator nodes and a server node. Based on sensor data, a control loop configures the actuators. Operational data is stored in a database and visually presented on a website. The website displays an overview of all the boreholes where all of the sensors data can be read. The control algorithm runs successfully according to its hierarchically priorities. The prototype works as a developement platform and a demonstrating prototype.
APA, Harvard, Vancouver, ISO, and other styles
9

Kordonska, Nataliya. "Enhancement of BTEX biodegradation in subsurface environments." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1997. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp01/MQ30960.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Favard, Alexandre. "Multicapteurs intégrés pour la détection des BTEX." Thesis, Aix-Marseille, 2018. http://www.theses.fr/2018AIXM0123/document.

Full text
Abstract:
La qualité de l’air extérieur (QAE) a fait l’objet d’une législation dès 1996 avec la loi LAURE. Depuis 2008, la directive européenne 2008/50/CE a instauré des obligations de mesure et de seuils à ne pas dépasser pour certains polluants à l’échelle européenne. Selon de nombreuses données toxicologiques et épidémiologiques, la pollution de l’air est à l’origine d’insuffisances respiratoires, d’asthme, de maladies cardiovasculaires et de cancers.Les composés organiques volatils (COV) et notamment le benzène, le toluène, l’ethylbenzène et les xylènes (les composés BTEX) sont des polluants avérés et participent grandement à la dégradation de la qualité de l’air intérieur et extérieur. Ce travail de thèse a concerné la réalisation d’un multicapteur de gaz à base d’oxyde métallique pour la détection de traces de BTEX dans le cadre du projet SMARTY (SMart AiR qualiTY). Un système de caractérisation électrique complet a été conçu et mise au point pour la détection de très faibles concentrations de BTEX (le ppb). Après une étude bibliographique, plusieurs matériaux ont été sélectionnés (WO3, ZnO, SnO2). Les caractérisations électriques des couches sensibles sélectionnées ont été effectuées sous air sec et sous différents taux d’humidité en présence de BTEX et de gaz interférents (NO2, CO2). Le WO3 a montré les meilleures performances en présence d’humidité et a été choisi pour le transfert de technologie qui accompagne les nouveaux transducteurs brevetés AMU. Le multicapteur à base de WO3 a montré une détection limite de 1 ppb sous 50% d’humidité relative et a permis de détecter et de quantifier de manière efficace les BTEX
Outdoor air quality is subjected to the law LAURE since 1996. In 2008, the european directive 2008/50/EC introduced measurement requirements and thresholds that should not be exceeded for certain pollutants on a european scale. According to several toxicological and epidemiological studies, air pollution causes respiratory failure, asthma, cardiovascular diseases and cancers. In Europe, air pollution is responsible for more than 300 000 early deaths a year.Volatile organic compounds (VOCs), particularly benzene, toluene, ethylbenzene and xylenes (BTEX compounds) are proven pollutants and play a major role in the degradation of indoor and outdoor air quality. This thesis is dedicated to the development of a metal oxide based multi-gas sensor for the detection of traces of BTEX within the framework of the SMARTY project (SMart AiR qualiTY). A complete electrical characterization system was designed and implemented for the detection of sub-ppm concentrations of BTEX.Based on the state-of-art, several materials were selected (WO3, ZnO, SnO2). The electrical characterizations of the selected sensitive layers were carried out under dry air and under different humidity levels in the presence of BTEX and interfering gases (NO2, CO2). Tungsten oxide (WO3) exhibits the best performance in the presence of moisture and is chosen for the technology transfer that accompanies the new patented AMU transducers. The WO3-based multi-sensor has a lower limit of detection (LOD) of 1 ppb at 50% relative humidity and effectively detects and quantifies BTEX
APA, Harvard, Vancouver, ISO, and other styles
11

Dragan, Adamović. "Model detekcije benzena, toluena, etilbenzena i ksilena u izduvnim gasovima motornih vozila primenom gasne hromatografije u funkciji procene zagađenja ambijentalnog vazduha." Phd thesis, Univerzitet u Novom Sadu, Fakultet tehničkih nauka u Novom Sadu, 2015. https://www.cris.uns.ac.rs/record.jsf?recordId=90997&source=NDLTD&language=en.

Full text
Abstract:
U okviru doktorske disertacije opisane su jedinstvene fiziĉko-hemijske karakteristikegrupe supstanci benzena, toluena, etilbenzena i ksilena koje pripadaju istraživanjimanajnovijeg trenda nauĉne javnosti. Posebno su opisane perzistencija ipseudoperzistencija, transport, distribucija i negativan i toksiĉan uticaj na zdravljeĉoveka i životnu sredinu. Sprovedena su eksperimentalna istraživanja zavisnostikoncentracionih nivoa BTEX jedinjenja u izduvnim gasovima i operativnih parametaraeksperimentalnog motora SUS. Na osnovu dobijenih rezultata eksperimentalnihistraživanja definisan je emisioni model BTEX jedinjenja simulacijom kretanjaputniĉkog automobila Fiat Punto Classic u skladu sa NEDC ciklusom koji naodgovarajući naĉin reprezentuje standarde uslove vožnje u evropskim gradovima.
In this thesis, the unique physicochemical characteristics of a group of substancesconsisting of benzene, toluene, ethylbenzene and xylene have been described.Special emphasis has been placed on their characteristics of persistence and pseudopersistence,transport, distribution and the negative and toxic influence on humanhealth and the environment. The experimental research of the interdependence of theconcentration levels of BTEX compounds in the exhaust gases and the operationalparameters of the experimental IC engine has been conducted. Based on theexperimental research results, the emission model of the BTEX compounds has beendefined by a simulation of movement of a Fiat Punto Classic passenger car inaccordance with the NEDC cycle, which appropriately represents the standard drivingconditions in European cities. Research conducted within the thesis represents thenewest trend of investigation in the scientific world.
APA, Harvard, Vancouver, ISO, and other styles
12

Marchetti, Maykel Douglas. "Tratamento de águas subterrâneas contaminadas com BTEX utilizando processo oxidativo de Fenton." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/75/75132/tde-11032010-111423/.

Full text
Abstract:
Há décadas enfrentamos as conseqüências causadas por atitudes poluidoras. Contudo, atualmente a preocupação ambiental aumentou devido aos efeitos potencialmente nocivos sobre a saúde humana, economia e meio ambiente.A contaminação do solo e das águas subterrâneas por compostos orgânicos voláteis é um problema que está se espalhando com rapidez, e uma das principais fontes poluidoras é o vazamento de tanques de armazenamento de combustível em auto-postos. A problemática desta contaminação é agravada tendo em vista que compostos tóxicos de solubilidade considerável em água, tais como BTEX, estão presentes nessa contaminação.Atualmente são utilizados métodos de tratamento, tais como a aeração, que apenas acabam transferindo os compostos orgânicos tóxicos da água para a atmosfera. O Processo Oxidativo Avançado de Fenton mostra-se promissor no tratamento de tais contaminações.Nossos objetivos foram testar o processo oxidativo e melhorar suas condições de aplicação, bem como projetar um equipamento capaz de realizar o processo de maneira automática.No presente trabalho, o POA mencionado mostrou-se eficiente e capaz de mineralizar os poluentes, reduzindo a poluição a níveis satisfatórios. As caracterizações foram feitas através de cromatografia gasosa, análise de metais através de espectroscopia de emissão por plasma e análise do carbono orgânico total.
From decades, the consequences caused by laid-back attitude towards environment are confronting people. However, currently, the environmental concerned was raised because of the potentially harmful effects on human health, economy and on the environment itself.The problem of soil and subterranean water contamination by volatile organic compounds is rapid spreading; being on of the main pollutant fount the leak of the fuel housing on the gas stations. This problem aggravates once toxic compounds which have considerable solubility on water, such as BTEX, are on this contamination.Currently, treatment methods are employed, such as aeration, which only transfers the toxic organic compounds from water to atmosphere. The Fenton advanced oxidative process manifests as a promising treatment of these contaminations.Our purpose was to test the oxidative process and improve the applicability conditions as well as project equipment able to accomplish the process on an automatic way.On this work the POA manifests efficient and able to mineralize the pollutants, decreasing the pollution to a satisfactory level. The characterization were made through gas chromatographic, the metal analyses were made by plasma emission spectroscopy and analysis of total organic carbon.
APA, Harvard, Vancouver, ISO, and other styles
13

Rosolino, Paula. "Utilização de espectrofotômetro de infravermelho portátil para a determinação quantitativa de compostos orgânicos voláteis (BTEX) em amostras de efluentes líquidos." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/6/6134/tde-07112012-161805/.

Full text
Abstract:
A avaliação da presença de compostos orgânicos voláteis nos efluentes líquidos é importante para atendimento à legislação vigente e proteção do sistema de esgotamento sanitário e da saúde ocupacional. Objetivos: o uso de técnica rápida de identificação e quantificação de compostos orgânicos voláteis do grupo BTEX presentes em amostras de efluentes líquidos através das emissões gasosas permite verificar quais delas não atendem à legislação vigente, através de faixas de concentração de interesse. A possibilidade de efetuar em campo essa avaliação promove maior agilidade nas ações de controle da qualidade do efluente bem como da exposição ocupacional. Também permite racionalizar os custos de monitoramento através da redução das amostras enviadas aos laboratórios. Materiais e métodos: os compostos avaliados causam agravos à saúde e, por serem altamente voláteis, possuem altos percentuais de distribuição no ar. O benzeno é comprovadamente cancerígeno, não existindo limites seguros para exposição a esse composto. A legislação brasileira fornece os subsídios necessários para o controle da produção, usos e disposição de BTEX. Há ações em andamento para um melhor controle e monitoramento da exposição ocupacional ao benzeno, em especial, e também ações para o monitoramento das populações expostas a ele. Com o objetivo de efetuar leituras no campo que identifiquem e quantifiquem os compostos do grupo BTEX, optou-se pela utilização de espectrofotômetro de infravermelho portátil. Resultados: os resultados das leituras das emissões desses compostos foram comparados com os resultados das análises de BTEX efetuadas nos efluentes líquidos. Para tanto, foram considerados os parâmetros existentes na legislação relativos à exposição ocupacional e à legislação de lançamento de efluentes. Conclusão: a avaliação dos resultados permite dizer que é factível a utilização da leitura das emissões gasosas para identificar a presença de BTEX em amostras de efluentes líquidos e que essas leituras podem quantificar valores que ultrapassem as faixas de concentração de interesse, através dos modelos de regressão identificados nessa avaliação. Para a construção de modelos de regressão mais confiáveis entre as concentrações das emissões gasosas e das concentrações no efluente líquido, são necessários estudos complementares.
The evaluation of the presence of volatile organic compounds in wastewater is important for compliance with current regulations, protection of the wastewater sewer systems and occupational health. Objectives: Identification and quantification of volatile organic compounds of BTEX group present in samples of liquid effluents through their gaseous emissions, allows checking which of them do not meet the current regulation, through concentration ranges of interest. The possibility of performing this evaluation in the field promotes greater flexibility in efforts to control the quality of the effluent as well as occupational exposure. It also allows streamlining the monitoring costs through reduction of liquid samples to be sent to laboratories. Materials and methods: The compounds evaluated cause health problems and for being highly volatile have high percentages of distribution in the air. Benzene is a proven carcinogen and there are no safe limits for exposure to this compound. Brazilian regulations provide the necessary subsidies for production control, uses and disposal of BTEX subsidies needed to control the production, uses and disposal of BTEX. There are ongoing activities to better control and monitoring of occupational exposure and also actions for monitoring populations exposed to benzene. An infrared spectrophotometer was used in air analyses to identify BTEX. Results: The results of the compounds emissions scans were compared with the results of BTEX analyzes in wastewater. For both parameters were considered in the regulation relating to occupational exposure and the rules of effluent discharge. Conclusion: The evaluation of the results allows saying that it is feasible to use gaseous emissions scans to identify the presence of BTEX in wastewater samples and they can indicate scans that exceed the concentration ranges of interest, through mathematical models this assessment. For mathematical models that provide precise curves of the correlation between the concentrations of gaseous emissions and liquid effluent concentrations, complementary studies are needed.
APA, Harvard, Vancouver, ISO, and other styles
14

Sterne, Lars. "Mathematical modelling of a biofilter for BTEX compounds." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1999. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp01/MQ35936.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Wentz, Jerome C. "West Virginia coal fly ash sorption of BTEX." Morgantown, W. Va. : [West Virginia University Libraries], 2004. https://etd.wvu.edu/etd/controller.jsp?moduleName=documentdata&jsp%5FetdId=3759.

Full text
Abstract:
Thesis (M.S.)--West Virginia University, 2004.
Title from document title page. Document formatted into pages; contains vi, 93 p. : ill. (some col.). Includes abstract. Includes bibliographical references (p. 47-52).
APA, Harvard, Vancouver, ISO, and other styles
16

Tecle, Aregai, Peter Kitanidis, and Martin Reinhard. "Biodegradability of BTEX Contaminants Under Natural Field Conditions." Arizona-Nevada Academy of Science, 1997. http://hdl.handle.net/10150/296486.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Ma, Wei. "Bioremediation of water contaminated with BTEX, TPH, and TCE." Thesis, University of Macau, 2008. http://umaclib3.umac.mo/record=b1795652.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Li, Jun Hui. "Aerobic bioremoval of CAHs and BTEX from contaminated soil." Thesis, University of Macau, 2012. http://umaclib3.umac.mo/record=b2590543.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Strauss, Johannes Mattheus. "Biofiltration of BTEX waste gases / by Johannes Mattheus Strauss." Thesis, North-West University, 2003. http://hdl.handle.net/10394/247.

Full text
Abstract:
A comparison of biofilter performance under different temperature conditions is of particular importance for the application and commercialization of biofiltration technology due to the fact that many waste gas streams are at elevated temperatures. The efficacy of higher temperature biofiltration reactors, therefore, has important practical and cost implications as it directly impacts on the need and cost for gas cooling prior to biofiltration treatment. In this study the performance of toluene degrading mesophilic (25°C) and thermophilic (50°C) composted pine bark biofilters were evaluated. The effect of oxygen concentrations on reactor performance was also evaluated, and comparisons made for both temperature conditions. Toluene, as part of the benzene, toluene, ethylbenzene and xylene (BTEX) group, are important solvents and constitutes a large percentage of petroleum. These compounds, mainly due to their solubility as well as being confirmed or suspected carcinogens, have been classified as environmental priority pollutants by the US Environmental Protection Agency with increasingly stringent regulations to avoid their release. Investigations were performed at loading rates ranging from 9 to 54 g m'3 h-', retention times of 0.25 to 3.9 minutes, and at various bed heights. Comparison of the performance using empirical models indicated that higher removal efficiencies would be obtained under thermophilic conditions, although a slightly longer retention time was required to obtain the same efficiency. Under thermophilic conditions toluene removal efficiencies exceeding 90% were obtained when the reactor was subjected to retention times in excess of 0.6 minutes (36 seconds) and loading rates below 54 g m-3 h-1. Under mesophilic conditions similar efficiencies would be obtained with a retention time of 0.32 minutes (19 seconds) and loading rates below 42 g m-3 h-1. The influence of oxygen at a single loading rate and retention time indicated reduced performance at oxygen concentrations below 5% for both operating temperatures. A previously developed diffusion reaction model was further applied to this comprehensive dataset and through a process of subset model parameter optimization and parameter sensitivity analyses, both reactor condition performances were simulated with a high degree of accuracy at steady state Conditions. Simulated results further emphasized that higher elimination rates of toluene could be obtained at thermophilic temperatures. BTEX substrate interactions, using this toluene-acclimatized biofilter consortium, were further investigated at a single loading rate of 18 g m-3 h- 1 and retention times ranging from 0.5 to 3 minutes. The mesophilic results obtained were modelled using Michaelis-Menten kinetics and an explicit finite difference scheme to generate Vm and Km parameters, of which the ratio can be used as an indication of the catalytic efficiency in order to quantify substrate interactions occurring within the biofilter. Toluene was found to enhance the catalytic efficiency for p-xylene, while catabolism of all other compounds was inhibited competitively by the presence of toluene. All BTEX compounds could be degraded by the microbial consortium even in the absence of toluene. The catalytic efficiency of the reactor for the compounds was in the order: ethylbenzene > benzene > o-xylene> m-xylene > p-xylene. The catalytic efficiency of the microbial consortium for toluene was reduced by the presence of all other BTEX compounds, with the greatest inhibitory effect caused by the presence of benzene, while o-xylene and p-xylene caused the least inhibitory effect. This BTEX substrate interaction study was further extended to include the thermophilic conditions at a similar loading to that of the mesophilic study, in order to compare results from both temperature conditions. Overall toluene degradation rates under mesophilic conditions were found to be superior to degradation rates of individual BEX compounds. With the exception of p-xylene, higher removal efficiencies were achieved for individual BEX compounds compared to toluene under thermophilic conditions. Overall BEX compound degradation under mesophilic conditions was ranked as ethylbenzene > benzene > o-xylene > m-xylene > p-xylene. Under thermophilic conditions overall BEX compound degradation was ranked as benzene > o-xylene > ethylbenzene > m-xylene > p-xylene. With the exception of o-xylene, the presence of toluene in paired mixtures with BEX compounds resulted in enhanced removal efficiencies of BEX compounds, both under mesophilic and thermophilic conditions. A substrate interaction index was calculated to compare removal efficiencies at a retention time of 0.83 minutes (50 seconds). A reduction in toluene removal efficiency (negative interaction) in the presence of individual BEX compounds was observed under mesophilic conditions, while enhanced toluene removal efficiency was achieved in the presence of other BEX compounds, with the exception of p-xylene under thermophilic conditions. This study illustrated the potential of biofiltration as an emerging technology, especially at elevated temperatures, but emphasized the complexity of interactions that might occur between individual compounds that could influence the performance of the reactors when treating mixed pollutant gas streams.
Thesis (Ph.D. (Microbiology))--North-West University, Potchefstroom Campus, 2004.
APA, Harvard, Vancouver, ISO, and other styles
20

Nerantzis, Panagiotis C. "Transport and fate of BTEX vapours in unsaturated soil." Thesis, University of Strathclyde, 2007. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.441878.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Medella, Ali. "MTBE, BTEX and oxygenates biodegradation in biomass concentrator reactors." Cincinnati, Ohio : University of Cincinnati, 2009. http://rave.ohiolink.edu/etdc/view.cgi?acc_num=ucin1254406627.

Full text
APA, Harvard, Vancouver, ISO, and other styles
22

Tavares, Jucelio Kilinski. "Remoção de compostos BTEX de soluções aquosas por adsorção." Florianópolis, SC, 2007. http://repositorio.ufsc.br/xmlui/handle/123456789/90492.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Química
Made available in DSpace on 2012-10-23T11:28:26Z (GMT). No. of bitstreams: 1 245694.pdf: 2608376 bytes, checksum: 77ab1513c72be33487ea76546bc9ddc4 (MD5)
A adsorção em coluna de leito fixo é um método de tratamento muito usado para a retirada de contaminantes de efluentes na indústria petroquímica. Neste trabalho é investigado o uso do carvão ativado de casca de coco no tratamento de correntes industriais aquosas, contaminadas com o BTEX, que é o benzeno, tolueno, etilbenzeno e o-xileno. Os compostos BTEX foram escolhidos, pela sua facilidade, frente aos outros hidrocarbonetos presentes no petróleo, de se misturar com a água e do grave impacto ambiental ocasionado pela presença dos mesmos nos cursos d'água, devido à sua elevada toxicidade. Foram feitos testes para a determinação de isotermas de equilíbrio e se observou que tanto o modelo de Langmuir, quanto o modelo de Freundlich, apresentaram um bom ajuste aos dados experimentais. Foram ainda realizados testes cinéticos em batelada para a obtenção do coeficiente de difusão efetiva para os compostos e testes cinéticos em contínuo para a obtenção das curvas de ruptura "breakthrough", sendo este teste para o benzeno realizado para diferentes condições de altura do leito e vazões. A melhor condição de operação, obtida experimentalmente para o benzeno, foi aplicada para os outros compostos, tolueno, etilbenzeno e o-xileno. Foi desenvolvido um modelo para a simulação das condições experimentais utilizando a linguagem de programação FORTRAN e o software comercial CFX. No algoritmo desenvolvido na linguagem FORTRAN, o ADSBTEX, foi utilizado o método de diferenças finitas para resolver as equações diferenciais que governam o fenômeno de adsorção no leito fixo. Através dos métodos CFD empregadas no software CFX foram geradas as malhas, aplicadas às condições de contorno e obtidas as soluções numéricas. Os resultados obtidos experimentalmente foram utilizados para corroborar os modelos e algoritmos numéricos desenvolvidos, verificando-se um desvio médio máximo de 7,5 %. Os modelos foram considerados representativos do processo em estudo e os resultados simulados adequados para a predição do comportamento do processo de adsorção em sistema contínuo.
APA, Harvard, Vancouver, ISO, and other styles
23

Mello, Josiane Maria Muneron de. "Biodegradação dos compostos BTEX em um reator com biofilme." Florianópolis, SC, 2007. http://repositorio.ufsc.br/xmlui/handle/123456789/90640.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Química.
Made available in DSpace on 2012-10-23T13:21:26Z (GMT). No. of bitstreams: 1 241371.pdf: 896009 bytes, checksum: 3b3351d5b6fe6532aaae1b164fa347a0 (MD5)
Atualmente diversos estudos estão sendo realizados com o objetivo de desenvolver unidades de tratamento de efluentes mais compactas que operem com maior flexibilidade e com um bom desempenho na remoção de compostos tóxicos como os BTEX (benzeno, tolueno, etilbenzeno e xilenos). Os compostos BTEX presentes nestes efluentes apresentam um elevado potencial de poluição, representando um sério risco ao meio ambiente e ao ser humano, sendo que o benzeno é considerado o mais tóxico, fato este que está relacionado diretamente ao seu potencial carcinogênico e mutagênico. Os maiores avanços na área de tratamento biológico de efluentes líquidos foram alcançados através de processos que utilizam biofilmes suportados em materiais inertes particulados que, através do processo de biodegradação, são capazes de degradar compostos tóxicos. Estes processos com biofilme aderido apresentam como vantagens: maior concentração de biomassa retida com uma atividade metabólica mais elevada; aplicação de maior carga orgânica; apresentam grande área de transferência de massa entre as fases; instalações mais compactas; sistemas mais estáveis e possuem uma maior capacidade para tolerar poluentes recalcitrantes e tóxicos que os processos convencionais. As operações favoráveis para operar plantas industriais que visam à biodegradação de compostos químicos podem ser preditas através da modelagem matemática e simulação numérica dos fenômenos envolvidos. No presente trabalho é utilizado um modelo de uma única equação para descrever o perfil de concentração dos compostos BTEX ao longo de um biorreator com biofilme em leito fixo, sendo que a equação considera os diferentes mecanismos que controlam a transferência de massa, tais como: efeitos de dispersão, convecção e reação na fase líquida, difusão e reação dentro do biofilme seguindo a cinética de reação de Michaelis-Menten. Este modelo matemático é válido desde que a condição de equilíbrio mássico local seja respeitada. Os parâmetros cinéticos dos compostos BTEX foram obtidos experimentalmente em um biorreator de leito fixo, em batelada, com biomassa imobilizada em carvão ativado sendo alimentado diariamente com solução de nutrientes e BTEX. Os ensaios experimentais mostraram que a biomassa presente no interior do biorreator é capaz de degradar todo o composto em um tempo de aproximadamente 300 minutos. A equação utilizada no modelo é discretizada utilizando o método de volumes finitos. O estudo utiliza um modelo computacional desenvolvido em linguagem Fortran para a simulação de diferentes parâmetros do processo a fim de prever a remoção dos compostos indesejáveis. Os parâmetros estudados foram: concentração de alimentação do composto, vazão de alimentação, área e comprimento do biorreator e a porosidade do leito. Os resultados obtidos através da simulação foram comparados com resultados experimentais encontrados na literatura, apresentando boa concordância. Os resultados das simulações mostraram que todos os parâmetros avaliados influenciam a biodegradação dos compostos BTEX, e que o modelo matemático e a metodologia numérica podem ser usados como uma ferramenta para prever o comportamento dinâmico e estacionário do processo de biodegradação podendo ser utilizado para determinar condições operacionais economicamente ótimas do sistema. Recently several studies are being carried out in order to develop units of effluent treatment more compact that operate with larger flexibility and with a good performance in the removal toxic compounds, as the BTEX (benzene, toluene, ethylbenzene and xylene). The compounds BTEX inside of this effluent have presented a high potential of pollution, representing a serious risk to the environment and to the human being, once the benzene is considered the most toxic one, fact this which is related directly to its mutagenic potential and malignant tumor. The great improvements in the field of biological treatment of liquid effluent were reached through the process that uses biofilm supported in particle inert materials that is capable of degrading toxic compounds by the process of biodegradation. These processes with an attached biofilm have presented some advantages, such as: larger biomass concentration retained with a more raised metabolic activity; application of a larger organic load; they have presented a great area of mass transfer between the phases, more compact installations, more stable systems and a larger capacity to tolerate recalcitrant and toxic pollutants than conventional processes. The favorable operations to operate industrial design that aim at the biodegradation of chemical compounds can be predicted through mathematical modeling and numerical simulation of the mass transfer phenomena. The present work uses a model of one single equation to describe the concentration profile of BTEX compounds throughout a fixed bed bioreactor with biofilm, once the equation considers the different mechanisms that control the mass transfer, such as: dispersion, convection and reaction effects in the liquid phase; diffusion and reaction inside the biofilm following the Michaelis-Menten's reaction kinetic. This mathematical model is valid since the local mass equilibrium condition is respected. The kinetic parameters of BTEX compounds were experimentally obtained in a fixed bed bioreactor in batch with biomass immobilized in activated-carbon being fed daily with solution of nutrients and BTEX. The experimental tests showed that the biomass inside of bioreactor is capable to degrade all compounds in a time of approximately 300 minutes. The equation used in the model is discretized using the finite volume method. This study uses a computational model developed in language FORTRAN to simulate various process parameters in order to predict the undesirable compounds removal. The studied parameters were: feed compound concentration, feed flow, area and length bioreactor and the bed porosity. The results obtained by simulation were compared with experimental results found in literature, presenting good correlation. The results of the simulations showed that all evaluated parameters influence the biodegradation of compounds BTEX, and that the mathematical model and the numerical methodology can be used as a tool to predict the dynamic and stationary behavior of biodegradation process being able to be used to determine optimum economically operational conditions of the system.
APA, Harvard, Vancouver, ISO, and other styles
24

Milesson, Joel, and Erika Abrahamsson. "Geoenergilager Xylem : Visualisering och lönsamhet." Thesis, Linnéuniversitetet, Institutionen för bygg- och energiteknik (BE), 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-27037.

Full text
Abstract:
Inom svensk process- och tillverkningsindustri finns det stora mängder spillvärme som sällan kommer till användning. Att hitta olika tekniska lösningar för att effektivt tillvarata denna spillvärme skapar både nytta ur ett hållbart perspektiv samt ur ett ekonomiskt perspektiv för företaget. I denna rapport presenteras en utarbetad beräkningsmodell i Excel. Beräkningsmodellen används för att uppskatta lönsamheten för anläggning av ett högtemperaturlager i berggrunden. Excel-filen ska kunna användas för företag som en första uppskattning om ett borrhålslager är ett alternativ för tillvaratagande av spillvärme. Utformningen av beräkningsmallen utgick från Xylems högtemperaturlager i Emmaboda. Beräkningsmallen testades på Xylems borrhålslager. Resultatet visar att 2166 MWh/år kan tas ut från lagret, vilket stämmer överens till 83 % med Xylems egna beräkningar. Borrhålslagrets verkningsgrad beräknades till 65 % vilket kan jämföras med de 68 % som Xylem kalkylerat med. Nyckelord: Borrhålslager, UTES-system, BTES-system, HT-BTES-system, geoenergi, spillvärme.
APA, Harvard, Vancouver, ISO, and other styles
25

Zoby, José Luiz Gomes. "Atenuação natural de pluma de contaminação de gasolina e etanol em água subterrânea." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/44/44133/tde-14032007-155415/.

Full text
Abstract:
Um estudo de caso e dois experimentos controlados de campo foram realizados, a fim de avaliar o impacto do etanol nos processos de atenuação natural que atuam em plumas de contaminação em fase dissolvida de gasolina. No estudo de caso, foi monitorada uma pluma de contaminação de E22 (gasolina com 22% de etanol em volume) em Itaguaí (RJ). Os dois experimentos controlados foram realizados no aqüífero de Borden, no Canadá, para estudar plumas de E10 e E95 (gasolinas com 10 e 95% de volume de etanol, respectivamente). Neste caso, foram realizadas injeções dos contaminantes abaixo do nível d\'água, gerando plumas que foram monitoradas. O etanol, em subsuperfície, particiona rapidamente para a água subterrânea, deixando a fase residual, e é transportado com a velocidade da água subterrânea. Os outros compostos orgânicos de gasolina migram com velocidades menores. Benzeno e tolueno apresentam velocidades mais próximas do etanol, enquanto trimetilbezenos e naftalenos são os mais retardados. Estas diferenças de migração dos compostos resultaram na separação espacial entre as plumas ao longo do período monitorado. A maior concentração de etanol detectada foi de 12.762 mg/L, que corresponde a um volume de etanol em água de 1,63%. As baixas concentrações de etanol não evidenciam que ele tenha exercido efeito cosolvente pronunciado na solubilidade dos compostos da gasolina. Os compostos orgânicos apresentaram perdas de massa ao longo do tempo de monitoramento. A biodegradação dos contaminantes foi observada pelo consumo de oxigênio dissolvido e metonogênese. O etanol apresentou a maior diminuição de massa e foi biotransformado mesmo sob condições anóxicas. O composto que apresentou a menos perda de massa foi o benzeno. A maior persistência de benzeno é atribuída à sua velocidade de migração próxima à água subterrânea associada ao efeito de consumo preferencial de receptores de elétrons pelo etanol. No estudo de caso, o desaparecimento de etanol pode estar relacionado à sua alta taxa de biodegradação, fato observado nos experimentos de campo. Entretanto, o efeito cosolvente na pluma, que explicaria o deplecionamento dos compostos mais móveis, como benzeno e tolueno, na pluma não foi comprovado nos experimentos.
A case study and two controlled field experiments were conducted to evaluate the impact of ethanol on the natural attenuation processes affecting dissolved phase of gasoline plumes. The case study was conducted in Itaguaí (RJ) where an E22 (gasoline with 22 % by volume of denatured ethanol) contaminant plume was studied. The controlled field experiments were conducted at the Borden aquifer in Canada to study plumes E10 and E95. In this case, contaminants were injected below the water table and plumes were monitored down gradient. In subsurface, ethanol partitions fastly from the residual phase and is transported with the ground water velocity. The other organic compounds migrate with lower velocities. Benzene and toluene present velocities close to ethanol, while trimethylbenzenes and naphthalene are the most retarded. These transport differences resulted in the spatial separation between the plumes throughout the monitoring period. The highest ethanol concentration detected was 12,762 mg/L, which corresponds to 1.63 % of ethanol volume in water. The ethanol concentrations detected do not support the cosolvency effect on the gasoline constituents of the plumes. The organic compounds presented mass losses throughout the monitoring period. Biodegradation was also demonstrated through dissolved oxygen consumption and methanogenesis. Ethanol presented the highest mass losses and was biotransformed under anoxic conditions. Benzene presented the smallest mass loss. Benzene´s higher persistence is related to the migration close to the ground water velocity and the preferential consumption of electron acceptors by ethanol. In the case study, the disappearance of ethanol can be related to its higher biodegradation rate, which was detected through the field experiments. However, the cosolvent effect in the plume, which would explain the depletion of the most mobile compounds such as benzene and toluene was not observed during the field experiments.
APA, Harvard, Vancouver, ISO, and other styles
26

Choi, Seng Fai. "Bio-remediation of BTEX-contaminated water with enhanced removal efficiency." Thesis, University of Macau, 2006. http://umaclib3.umac.mo/record=b1636324.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Ucankus, Tugba. "Modeling Natural Attenuation Of Petroleum Hydrocarbons (btex) In Heterogeneous Aquifers." Master's thesis, METU, 2005. http://etd.lib.metu.edu.tr/upload/12606869/index.pdf.

Full text
Abstract:
Natural Attenuation can be an effective cleanup option for remediation of Groundwater contamination by BTEX. One of the important aspects of the methodology that has been recognized recently is that mass removal rates, the most important parameters used to determine effectiveness of the methodology, is controlled by groundwater flow regime, which to a large extent controlled by aquifer heterogeneity. Considering this recognition, the primary objective of this research is to quantitatively describe the relationship between natural attenuation rates of BTEX and aquifer heterogeneity using numerical solution techniques. To represent different levels of aquifer heterogeneity, hydraulic conductivity distributions are simulated using Turning Bands Algorithm, changing statistical parameters Coefficient of Variation (CV) and correlation length (h). Visual MODFLOW is used to model the transport of BTEX contamination, at different hydraulic conductivity fields. Degradation rates are calculated by Buscheck&
Alcantar and Conservative Tracer Methods. The results show that, for a given h, as CV increases, the plume slows down and stays longer at the domain, so areal extent of plume decreases. For anisotropic field, plumes are more dispersed along x and y-direction, and areal extents of the plumes are greater. During MNA feasibility studies, for the aquifer heterogeneity level of CV and h smaller than 100 % and 10 m, respectively, a minimum recommended biodegradation rate constant of 0.02 d-1 can be used, whereas for the aquifer heterogeneity level of CV and h greater than 100 % and 10 m, respectively, using a minimum biodegradation rate constant of 0.06 d-1 can be recommended.
APA, Harvard, Vancouver, ISO, and other styles
28

Donaire, Patricia Pulcini Rosvald. "Tratamento de agua subterranea contaminada com BTEX utilizando fotocatalise heterogenea." [s.n.], 2007. http://repositorio.unicamp.br/jspui/handle/REPOSIP/248928.

Full text
Abstract:
Orientador: Nelson Eduardo Duran Caballero
Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica
Made available in DSpace on 2018-08-10T05:06:09Z (GMT). No. of bitstreams: 1 Donaire_PatriciaPulciniRosvald_D.pdf: 1368968 bytes, checksum: 36ddc25863076b787c4847f7b99b272a (MD5) Previous issue date: 2007
Resumo: O presente trabalho trata do desenvolvimento de um reator tubular fotocatalítico aplicado ao tratamento de águas superficiais e subterrâneas contaminadas com compostos orgânicos voláteis, mais especificamente benzeno, tolueno, etilbenzeno e xileno (BTEX). O reator opera com recirculação da amostra e é constituído por dois catalisadores semicondutores, o dióxido de titânio e o dióxido de zircônio (TiO2/ZrO2). Estes catalisadores foram depositados sobre substratos de vidro na forma de filme misto e ativados com luz artificial proveniente de 2 lâmpadas de luz negra de 15 W cada, representando uma intensidade luminosa total de 3,6 mW cm. Os resultados demonstraram a viabilidade da utilização da fotocatálise heterogênea através da deposição de 15 camadas do filme misto sobre a matriz de vidro. A irradiação de água deionizada contaminada com 10 mg L de BTEX resultou em 95,9% de remoção destes compostos em pH 6,6 e vazão de recirculação de 280 mL min , onde somente o benzeno não alcançou o limite permitido pela legislação. A quantificação dos analitos foi realizada utilizando-se microextração em fase sólida (SPME). Observou-se uma cinética de pseudo-primeira ordem sendo a concentração inicial um fator limitante na taxa de degradação. A acetofenona foi a espécie intermediária detectada durante o processo fotocatalítico. No experimento de toxicidade utilizando Daphnia similis como organismo teste, a remoção de toxicidade foi atingida após 30 min de tratamento de água contaminada com gasolina onde o CE50-48 h inicial médio foi de 14,1% atingindo um CE50-48 h final médio de 84,3%
Abstract: The present work deals with the development of a photocatalytic tubular reactor to treat superficial and groundwaters contaminated with organic volatile compounds, more specifically benzene, toluene, ethylbenzene and xylene (BTEX). The reactor was operated with sample recirculation and it was constituted by two semiconductors catalysts, the titanium dioxide and the zirconium dioxide (TiO2/ZrO2). These catalysts were deposited over glass substrate in the form of mixed film and activated with artificial light originated from two 15 W black light lamps representing an average light intensity of 3.6 mW cm. The results showed the viability of heterogeneous photocatalysis using a deposition of 15 mixed film layers over the glass matrix. The photodegradation of deionized water contaminated with 10 mg L of BTEX gave a 95.9% of BTEX removal at pH 6.6 with a recirculation flow of 280 mL min . Among the other components of BTEX, only the benzene did not reach the permitted limit by legislation. The analytes were quantified by solid phase microextraction (SPME). The kinetic of pseudo-first order was observed and being the initial concentration a limiting factor in the degradation rate. The acetophenone was the intermediate species detected during photocatalytic process. In the toxicity experiment using Daphnia similis as organism test, the toxicity removal was reached after 30 min of treatment of contaminated water with gasoline where the initial average CE50-48 h was 14.1 % and reaching a final average CE50-48 h of the 84.3%
Doutorado
Quimica Analitica
Doutor em Quimica
APA, Harvard, Vancouver, ISO, and other styles
29

Firmino, Paulo Igor Milen. "Tratamento AnaerÃbio e MicroaerÃbio de Ãguas SintÃticas Contaminadas com BTEX." Universidade Federal do CearÃ, 2013. http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=10242.

Full text
Abstract:
CoordenaÃÃo de AperfeiÃoamento de NÃvel Superior
O presente estudo teve o objetivo de avaliar o uso de reatores biolÃgicos, sob condiÃÃes anaerÃbias e microaerÃbias, como opÃÃo de biorremediaÃÃo ex situ de Ãguas contaminadas com BTEX. Inicialmente, foi desenvolvido, otimizado e validado um mÃtodo analÃtico para a detecÃÃo e quantificaÃÃo de BTEX em Ãguas e efluentes, o qual consistia em extraÃÃo por headspace seguida de cromatografia gasosa com detecÃÃo por fotoionizaÃÃo. Posteriormente, foram conduzidos experimentos em fluxo contÃnuo em dois reatores anaerÃbios mesofÃlicos (27 ÂC) â um deles operado sob condiÃÃes metanogÃnicas e, em seguida, sob condiÃÃes microaerÃbias, e o outro, apenas sob condiÃÃes sulfetogÃnicas â a fim de verificar a melhor condiÃÃo operacional para a remoÃÃo de BTEX. Os reatores foram alimentados com Ãgua contaminada com BTEX (~3 mgÂL-1 de cada composto) e etanol (co-substrato), e, dependendo da condiÃÃo redox avaliada, investigou-se o efeito de diferentes parÃmetros operacionais, tais como tempo de detenÃÃo hidrÃulica (24, 36 e 48 h), recirculaÃÃo de efluente, concentraÃÃo de co-substrato, relaÃÃo DQO/SO4 2- e microaeraÃÃo, no desempenho de remoÃÃo de BTEX. AlÃm disso, o reator metanogÃnico sob condiÃÃes microaerÃbias foi submetido a simulaÃÃes de choques de carga e de ausÃncia desses compostos, e de falhas operacionais, como desligamento do sistema e desligamento da microaeraÃÃo, para verificaÃÃo de sua robustez. Sob condiÃÃes metanogÃnicas, dependendo do composto, as eficiÃncias de remoÃÃo variaram de 38 a 97%. PorÃm, o aumento da carga aplicada de BTEX, em consequÃncia da reduÃÃo do tempo de detenÃÃo hidrÃulica de 48 para 24 h, parece ter afetado negativamente o processo de remoÃÃo. Ainda sob condiÃÃes metanogÃnicas, tambÃm se verificou o efeito da recirculaÃÃo de efluente na remoÃÃo de BTEX para altas e baixas concentraÃÃes de co-substrato (etanol). Quando altas concentraÃÃes de etanol foram utilizadas, o impacto da recirculaÃÃo de efluente nÃo foi evidente, jà que, provavelmente, a elevada produÃÃo de biogÃs teria sido suficiente para garantir uma transferÃncia de massa efetiva. Sob condiÃÃes sulfetogÃnicas, a adiÃÃo de sulfato em diversas relaÃÃes DQO/SO4 2- nÃo alterou a remoÃÃo de BTEX, sugerindo que as bactÃrias redutoras de sulfato nÃo estariam diretamente relacionadas à ativaÃÃo inicial dos compostos aromÃticos. Sob condiÃÃes microaerÃbias, elevadas eficiÃncias de remoÃÃo de BTEX foram alcanÃadas (> 90%). à provÃvel que a adiÃÃo de baixas concentraÃÃes de oxigÃnio tenha facilitado a ativaÃÃo inicial dos compostos BTEX, a qual à considerada a etapa limitante do processo de degradaÃÃo anaerÃbia, principalmente para o benzeno. Ainda, constatou-se que a presenÃa de altas concentraÃÃes de etanol afetou negativamente a remoÃÃo de BTEX, notadamente para o benzeno, sob as diferentes condiÃÃes redox testadas, jà que à um substrato preferencialmente degradÃvel em relaÃÃo aos compostos aromÃticos. Finalmente, com relaÃÃo à robustez do reator metanogÃnico sob condiÃÃes microaerÃbias, o sistema conseguiu lidar com os choques de carga de BTEX embora choques consecutivos tenham aumentado seu tempo de recuperaÃÃo. O perÃodo de ausÃncia de BTEX parece ter prejudicado a microbiota do reator, pois a qualidade do efluente deteriorou-se consideravelmente apÃs reintroduÃÃo dos compostos. O desligamento da microaeraÃÃo impactou negativamente a remoÃÃo de BTEX, mas o sistema recuperou-se rapidamente apÃs restabelecimento das condiÃÃes microaerÃbias.
The present study aimed to evaluate the use of biological reactors under anaerobic and microaerobic conditions, as an option of ex situ bioremediation of BTEX-contaminated waters. Initially, an analytical method for BTEX detection and quantification in waters and wastewaters, which consisted of headspace extraction followed by gas chromatography with detection by photoionization, was developed, optimized and validated. Subsequently, continuous-flow experiments were conducted in two mesophilic (27 ÂC) anaerobic reactors â one of them operated under methanogenic conditions and, afterwards, under microaerobic conditions, and the other one only under sulfidogenic conditions â a in order to determine the best operational condition for BTEX removal. The reactors were fed with water contaminated with BTEX (~3 mgÂL-1 of each compound) and ethanol (co-substrate), and, depending on the redox condition evaluated, the effect of some operational parameters, such as hydraulic retention time (24, 36 and 48 h), effluent recirculation, co-substrate concentration, DQO/SO4 2- ratio and microaeration, was investigated in BTEX removal performance. Furthermore, the methanogenic reactor under microaerobic conditions was submitted to simulated situations of shock loading and absence of these compounds, and operational failures, such as system and microaeration shutdown to assess its robustness. Under methanogenic conditions, depending on the compound, removal efficiencies ranged from 38 to 97%. However, the increase of applied BTEX load, as a consequence of hydraulic detention time reduction from 48 to 24 h, seems to have adversely affected the removal process. Moreover, under methanogenic conditions, the effluent recirculation effect on BTEX removal was also assessed when high and low co-substrate (ethanol) concentrations were applied. For high ethanol concentrations, the impact of effluent recirculation was not evident since, probably, the high biogas production would have been sufficient to ensure effective mass transfer. Under sulfidogenic conditions, sulfate addition at different DQO/SO4 2- ratios did not change BTEX removal, which suggests sulfate-reducing bacteria would not be directly related to initial activation of aromatic compounds. Under microaerobic conditions, high BTEX removal efficiencies were achieved (> 90%). It is likely the addition of low oxygen concentrations has facilitated the initial activation of BTEX compounds, which is considered the limiting step of the anaerobic degradation process, mainly for benzene. Furthermore, the presence of high ethanol concentrations negatively affected BTEX removal, particularly for benzene, under the different redox conditions tested, since it is a preferentially degradable substrate when compared to the aromatic compounds. Finally, regarding the methanogenic reactor robustness under microaerobic conditions, the system could cope with BTEX load shocks although consecutive shocks have increased its recovery time. The period of BTEX absence seems to have negatively affected the reactor microbiota because the effluent quality deteriorated considerably after compounds reintroduction. The microaeration shutdown also negatively impacted the removal of BTEX, but the system recovered quickly after microaerobic conditions reestablishment.
APA, Harvard, Vancouver, ISO, and other styles
30

Lourenço, Edneia Santos de Oliveira. "Avaliação físico-química da remediação de solos contaminados por BTEX." Universidade Estadual do Oeste do Parana, 2006. http://tede.unioeste.br:8080/tede/handle/tede/343.

Full text
Abstract:
Made available in DSpace on 2017-05-12T14:48:10Z (GMT). No. of bitstreams: 1 Edneia Santos Oliveira Lourenco.pdf: 5280645 bytes, checksum: bb2af8a91bbf46aad38c5e7d4f97076d (MD5) Previous issue date: 2006-07-13
This research had as objective to evaluate the efficiency of the reactive means in the removal of aromatical hydrocarbons BTEX (Benzene, Toluene, Etil Benzene and Xylenes) in the ground, coming of leak of gasoline, either in fuel stations or underground tanks, and to explain the physico-chemical mechanisms that occuring on the system. The experiment was carried in laboratorial scale, in two types of permeable reactive barriers (PRB), called of AS (H2O2 + soil ) and ACA (H2O2 + activated coal) with the purpose to reduce the BTEX concentration through oxidation reaction or activated coal adsorption. For analysis of the efficiency of the barriers the BTEX concentrations in the sample of the gasoline when entering in the PRB and of the percolate in times of retention pre-established of 24, 36, 48, 60, 72 and 84 hours, using gas chromatography. The gotten results had shown that the two reactive barriers had reduced the BTEX concentration, being the ACA barrier the most efficient one. The effect has been attributed to the activated coal, which accomplishes the BTEX natural adsorption due to similarity in the polarity of its molecule with the BTEX composites, and still it acts as catalyst improving the oxidant action of hydrogen peroxide. The process, beyond to be efficient in the reduction of the BTEX concentrations, presents low cost and the advantage of the activated coal be regenerated.
Esta pesquisa teve como objetivo avaliar a eficiência dos meios reativos na remoção de hidrocarbonetos aromáticos BTEX (Benzeno, Tolueno, Etilbenzeno e Xilenos) no solo, provenientes de vazamento de gasolina, seja em postos de combustíveis ou em tanques subterrâneos e explicar os mecanismos físico-químicos que ocorrem no sistema. O experimento foi realizado em escala laboratorial, em dois tipos de barreiras reativas permeáveis (BRP), denominadas de AS (H2O2+ solo) e de ACA (H2O2 + carvão ativado) com a finalidade de reduzir a concentração dos BTEX por meio de reação de oxidação ou por adsorção do carvão ativado. Para análise da eficiência das barreiras foram determinadas as concentrações dos BTEX presentes na amostra da gasolina ao entrar na BRP e do percolado em tempos de retenção pré-estabelecidos de 24, 36, 48, 60, 72 e 84 horas, utilizando cromatografia gasosa. Os resultados obtidos mostraram que as duas barreiras reativas reduziram as concentrações dos BTEX, sendo a barreira ACA a mais eficiente. O efeito foi atribuído ao carvão ativado, que realiza a adsorção natural dos BTEX, devido à semelhança na polaridade de sua molécula com os compostos BTEX, além de atuar como catalisador melhorando a ação oxidante do peróxido de hidrogênio. O processo, além de ser eficiente na redução das concentrações dos BTEX, apresenta baixo custo e o carvão ativado pode ser regenerado.
APA, Harvard, Vancouver, ISO, and other styles
31

Firmino, Paulo Igor Milen. "Tratamento anaeróbio e microaeróbio de águas sintéticas contaminadas com BTEX." reponame:Repositório Institucional da UFC, 2013. http://www.repositorio.ufc.br/handle/riufc/7673.

Full text
Abstract:
FIRMINO, P. I. M. Tratamento anaeróbio e microaeróbio de águas sintéticas contaminadas com BTEX. 2013. 168 f. Tese (Doutorado em Engenharia Civil: Saneamento Ambiental) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2013.
Submitted by Marlene Sousa (mmarlene@ufc.br) on 2014-03-13T18:37:52Z No. of bitstreams: 1 2013_tese_pimfirmino.pdf: 2214781 bytes, checksum: b9c46be4f78117aa8926fda63dba863f (MD5)
Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2014-03-13T18:38:33Z (GMT) No. of bitstreams: 1 2013_tese_pimfirmino.pdf: 2214781 bytes, checksum: b9c46be4f78117aa8926fda63dba863f (MD5)
Made available in DSpace on 2014-03-13T18:38:33Z (GMT). No. of bitstreams: 1 2013_tese_pimfirmino.pdf: 2214781 bytes, checksum: b9c46be4f78117aa8926fda63dba863f (MD5) Previous issue date: 2013-07-19
The present study aimed to evaluate the use of biological reactors under anaerobic and microaerobic conditions, as an option of ex situ bioremediation of BTEX-contaminated waters. Initially, an analytical method for BTEX detection and quantification in waters and wastewaters, which consisted of headspace extraction followed by gas chromatography with detection by photoionization, was developed, optimized and validated. Subsequently, continuous-flow experiments were conducted in two mesophilic (27 °C) anaerobic reactors – one of them operated under methanogenic conditions and, afterwards, under microaerobic conditions, and the other one only under sulfidogenic conditions – a in order to determine the best operational condition for BTEX removal. The reactors were fed with water contaminated with BTEX (~3 mg·L-1 of each compound) and ethanol (co-substrate), and, depending on the redox condition evaluated, the effect of some operational parameters, such as hydraulic retention time (24, 36 and 48 h), effluent recirculation, co-substrate concentration, DQO/SO4 2- ratio and microaeration, was investigated in BTEX removal performance. Furthermore, the methanogenic reactor under microaerobic conditions was submitted to simulated situations of shock loading and absence of these compounds, and operational failures, such as system and microaeration shutdown to assess its robustness. Under methanogenic conditions, depending on the compound, removal efficiencies ranged from 38 to 97%. However, the increase of applied BTEX load, as a consequence of hydraulic detention time reduction from 48 to 24 h, seems to have adversely affected the removal process. Moreover, under methanogenic conditions, the effluent recirculation effect on BTEX removal was also assessed when high and low co-substrate (ethanol) concentrations were applied. For high ethanol concentrations, the impact of effluent recirculation was not evident since, probably, the high biogas production would have been sufficient to ensure effective mass transfer. Under sulfidogenic conditions, sulfate addition at different DQO/SO4 2- ratios did not change BTEX removal, which suggests sulfate-reducing bacteria would not be directly related to initial activation of aromatic compounds. Under microaerobic conditions, high BTEX removal efficiencies were achieved (> 90%). It is likely the addition of low oxygen concentrations has facilitated the initial activation of BTEX compounds, which is considered the limiting step of the anaerobic degradation process, mainly for benzene. Furthermore, the presence of high ethanol concentrations negatively affected BTEX removal, particularly for benzene, under the different redox conditions tested, since it is a preferentially degradable substrate when compared to the aromatic compounds. Finally, regarding the methanogenic reactor robustness under microaerobic conditions, the system could cope with BTEX load shocks although consecutive shocks have increased its recovery time. The period of BTEX absence seems to have negatively affected the reactor microbiota because the effluent quality deteriorated considerably after compounds reintroduction. The microaeration shutdown also negatively impacted the removal of BTEX, but the system recovered quickly after microaerobic conditions reestablishment.
O presente estudo teve o objetivo de avaliar o uso de reatores biológicos, sob condições anaeróbias e microaeróbias, como opção de biorremediação ex situ de águas contaminadas com BTEX. Inicialmente, foi desenvolvido, otimizado e validado um método analítico para a detecção e quantificação de BTEX em águas e efluentes, o qual consistia em extração por headspace seguida de cromatografia gasosa com detecção por fotoionização. Posteriormente, foram conduzidos experimentos em fluxo contínuo em dois reatores anaeróbios mesofílicos (27 °C) – um deles operado sob condições metanogênicas e, em seguida, sob condições microaeróbias, e o outro, apenas sob condições sulfetogênicas – a fim de verificar a melhor condição operacional para a remoção de BTEX. Os reatores foram alimentados com água contaminada com BTEX (~3 mg·L-1 de cada composto) e etanol (co-substrato), e, dependendo da condição redox avaliada, investigou-se o efeito de diferentes parâmetros operacionais, tais como tempo de detenção hidráulica (24, 36 e 48 h), recirculação de efluente, concentração de co-substrato, relação DQO/SO4 2- e microaeração, no desempenho de remoção de BTEX. Além disso, o reator metanogênico sob condições microaeróbias foi submetido a simulações de choques de carga e de ausência desses compostos, e de falhas operacionais, como desligamento do sistema e desligamento da microaeração, para verificação de sua robustez. Sob condições metanogênicas, dependendo do composto, as eficiências de remoção variaram de 38 a 97%. Porém, o aumento da carga aplicada de BTEX, em consequência da redução do tempo de detenção hidráulica de 48 para 24 h, parece ter afetado negativamente o processo de remoção. Ainda sob condições metanogênicas, também se verificou o efeito da recirculação de efluente na remoção de BTEX para altas e baixas concentrações de co-substrato (etanol). Quando altas concentrações de etanol foram utilizadas, o impacto da recirculação de efluente não foi evidente, já que, provavelmente, a elevada produção de biogás teria sido suficiente para garantir uma transferência de massa efetiva. Sob condições sulfetogênicas, a adição de sulfato em diversas relações DQO/SO4 2- não alterou a remoção de BTEX, sugerindo que as bactérias redutoras de sulfato não estariam diretamente relacionadas à ativação inicial dos compostos aromáticos. Sob condições microaeróbias, elevadas eficiências de remoção de BTEX foram alcançadas (> 90%). É provável que a adição de baixas concentrações de oxigênio tenha facilitado a ativação inicial dos compostos BTEX, a qual é considerada a etapa limitante do processo de degradação anaeróbia, principalmente para o benzeno. Ainda, constatou-se que a presença de altas concentrações de etanol afetou negativamente a remoção de BTEX, notadamente para o benzeno, sob as diferentes condições redox testadas, já que é um substrato preferencialmente degradável em relação aos compostos aromáticos. Finalmente, com relação à robustez do reator metanogênico sob condições microaeróbias, o sistema conseguiu lidar com os choques de carga de BTEX embora choques consecutivos tenham aumentado seu tempo de recuperação. O período de ausência de BTEX parece ter prejudicado a microbiota do reator, pois a qualidade do efluente deteriorou-se consideravelmente após reintrodução dos compostos. O desligamento da microaeração impactou negativamente a remoção de BTEX, mas o sistema recuperou-se rapidamente após restabelecimento das condições microaeróbias.
APA, Harvard, Vancouver, ISO, and other styles
32

Lopes, Verushka Symonne de Medeiros. "Avalia??o preliminar da contamina??o por BTEX, em ?gua subterr?nea de po?os tubulares, no munic?pio de Natal-RN." Universidade Federal do Rio Grande do Norte, 2011. http://repositorio.ufrn.br:8080/jspui/handle/123456789/12958.

Full text
Abstract:
Made available in DSpace on 2014-12-17T14:08:47Z (GMT). No. of bitstreams: 1 VerushkaSML_DISSERT.pdf: 2610302 bytes, checksum: 15f9dcee57e4dd025cfdc5dd4c655a36 (MD5) Previous issue date: 2011-08-02
Among the different types of pollutants typically attributed to human activities, the petroleum products are one of the most important because of its toxic potential. This toxicity is attributed to the presence of substances such as benzene and its derivatives are very toxic to the central nervous system of man, with chronic toxicity, even in small concentrations. The area chosen for study was the city of Natal, capital of Rio Grande do Norte, where samples were collected in six different areas in the city, comprising 10 wells located in the urban area, being carried out in three distinct periods March/2009, December / June/2010 and 2009, and were evaluated for contamination by volatile hydrocarbons (BTEX - benzene, toluene, ethylbenzene and xylenes), so this work aimed to assess the quality of groundwater wells that supply funding for public supply and trade in the urban area of the city of Natal, in Rio Grande do Norte, contributing to the environmental assessment of the municipality. The analysis of BTEX in water was performed according to EPA Method 8021b. Was used the technique of headspace (TriPlus TP100) coupled to high resolution gas chromatography with selective photoionization detector (PID) and flame ionization (FID) - model Trace GC Ultra, Thermo Electron Corporation brand. The procedure adopted allowed the detection of concentrations of the order of μg.L-1. Data analysis with respect to BTEX in groundwater in the area monitored so far, shows that water quality is still preserved, because it exceeds the limits imposed by the potability Resolution CONAMA N?. 396, April 2008
Dentre os diferentes tipos de poluentes tipicamente atribu?dos ?s atividades humanas, os produtos de petr?leo s?o um dos mais relevantes em raz?o de seu potencial t?xico. Esta toxicidade ? atribu?da ? presen?a de subst?ncias como benzeno e seus derivados que s?o muito t?xicos ao sistema nervoso central do homem, apresentando toxicidade cr?nica, mesmo em pequenas concentra??es. A ?rea escolhida para estudo foi o munic?pio de Natal, capital do estado do Rio Grande do Norte, onde foram coletadas amostras em 6 diferentes zonas no munic?pio, compreendendo 10 po?os localizados na zona urbana, sendo realizadas em 3 per?odos distintos mar?o/2009, dezembro/2009 e junho/2010; e foram avaliadas a contamina??o por hidrocarbonetos vol?teis (BTEX benzeno, tolueno, etilbenzeno e os xilenos), portanto este trabalho, teve como principal objetivo, avaliar a qualidade das ?guas subterr?neas que abastecem alguns po?os de capta??o destinados ao abastecimento p?blico e comercial, na regi?o urbana do munic?pio de Natal, no Estado do Rio Grande do Norte, contribuindo para o diagn?stico ambiental do munic?pio. A an?lise de BTEX em ?gua foi realizada de acordo com o m?todo EPA 8021b. Foi utilizada a t?cnica de headspace (TriPlus TP100) acoplado ? cromatografia gasosa de alta resolu??o com detector seletivo de fotoioniza??o (PID) e ioniza??o em chama (FID) - modelo Trace GC Ultra, marca Thermo Electron Corporation. O procedimento adotado permitiu a detec??o de concentra??es da ordem de μg.L-1. A an?lise dos dados com rela??o aos BTEX nas ?guas subterr?neas, no dom?nio monitorado at? este momento, mostra que a qualidade da ?gua ainda est? preservada, pois n?o ultrapassa os limites de potabilidade impostos pela Resolu??o CONAMA n? 396 de abril de 2008
APA, Harvard, Vancouver, ISO, and other styles
33

Santos, Karla Gasparini dos. "Mapeamento fino de QTL associados à resistência ao carrapato em bovinos de leite." Universidade Federal de Juiz de Fora (UFJF), 2011. https://repositorio.ufjf.br/jspui/handle/ufjf/2499.

Full text
Abstract:
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-09-15T13:54:35Z No. of bitstreams: 1 karlagasparinidossantos.pdf: 1186792 bytes, checksum: dac7f21d89dd87a474e971fead9a7387 (MD5)
Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-09-26T20:20:26Z (GMT) No. of bitstreams: 1 karlagasparinidossantos.pdf: 1186792 bytes, checksum: dac7f21d89dd87a474e971fead9a7387 (MD5)
Made available in DSpace on 2016-09-26T20:20:26Z (GMT). No. of bitstreams: 1 karlagasparinidossantos.pdf: 1186792 bytes, checksum: dac7f21d89dd87a474e971fead9a7387 (MD5) Previous issue date: 2011-08
Em países de clima tropical, os prejuízos causados pelo carrapato Riphichephalus (Boophilus) microplus causam grande impacto nos sistemas de produção bovino. A identificação de regiões genômicas e marcadores de DNA associados à resistência ao parasita poderão ser utilizados como estratégia para seleção de animais mais resistentes. Já foram descritos sete QTL relacionados à resistência ao carrapato bovino, porém, os estudos iniciais geralmente detectam QTL com uma resolução baixa ou moderada, sendo necessário o posterior refinamento da região onde o mesmo foi detectado. Dessa forma, esse trabalho teve como objetivo refinar a posição dos QTL previamente identificados com a adição de marcadores microssatélites em uma população bovina F2 formada a partir do cruzamento entre animais Gir e Holandês. Amostras de sêmen e sangue foram submetidas à extração de DNA e posterior PCR com os marcadores microssatélites. Os produtos de PCR foram detectados utilizando o seqüenciador automático de DNA MegaBACE 1000 e as análises estatísticas foram feitas utilizando o software GridQTL. As análises realizadas nos cromossomos 2, 5, 10, 11, 21, 23 e 27 confirmaram a presença dos QTL encontrados anteriormente e reduziram significativamente os intervalos de confiança da maioria dos QTL. Os QTL encontrados no BTA 2 e 27 foram significativos a Pc<0.05, aqueles localizados no BTA 5, 10, 11, 21 e 23 foram significativos a Pc<0.01. O BTA 2 sofreu redução no intervalo de confiança de 12 cM passando de 22 para 10 cM, assim como o BTA 5 que passou de 20 para 8 cM. No BTA 10 foi confirmada a presença de dois picos de QTL com intervalo de confiança de 27cM anteriormente detectado em 47 cM. O BTA 11 passou a apresentar um intervalo de confiança de 19 cM e BTA 21 de 36 cM sofreu redução para 26 cM. O BTA 23 apresentou a menor redução no intervalo de confiança na estação de chuva passando de 17 para 14 cM e na seca manteve inalterado com I.C. de 12 cM, assim como o BTA 27 que sofreu redução de apenas 1 cM passando para 7 cM. A adição de marcadores e a redução no intervalo de confiança de QTL previamente encontrados é um importante passo para a identificação de genes relacionados à resistência ao carrapato.
In tropical countries, losses caused by tick Rhipichephalus (Boophilus) microplus causes a great impact on cattle production systems. The identification of genomic regions and DNA markers associated to the parasite resistance may be used to select resistant animals. Seven QTL associated with tick resistance were described, however, the initial studies detect QTL with low or moderate resolution, being necessary the refinement of the regions where the QTL were detected. Thus, the aim of this work was refine the position of QTL previous identified with addiction of microsatellite markers in Gir X Holstein F2 population. Semen and blood samples were submitted to DNA extraction and then, the PCR were done using microsatellite markers. The PCR products were detected using DNA automatic sequencer MegaBACE1000 and the statistical analysis was performed using GridQTL software. The analysis performed on chromosome 2, 5, 10, 11, 21, 23 and 27 confirmed the presence of QTL previously found and the confidence intervals were significantly reduced in most of QTL. The QTL found on the BTA 2 and 27 were significant at Pc<0.05 and those located on BTA 5, 10, 11, 21 and 23 were significant at Pc<0.01. The BTA 2 was reduced 12 cM in the C.I., from 22 to 10 cM, and BTA 5 from 20 to 8. In BTA 10 was confirmed the presence of two QTL peaks with C.I. 27 cM, previously detected in 47 cM. BTA 11 reduced C.I. to 19 cM and BTA 21 reduced from 36 cM to 26 cM. BTA 23 showed the smallest reduction in C.I. in the rainy season, from 17 to 14 cM and in dry season the C.I remained unchanged with 12 cM, as the BTA 27 that reduced only 1 cM reaching 7 cM. The addiction of markers and the reduction in the confidence interval of QTL previously found is an important step to identify genes related to ticks resistance.
APA, Harvard, Vancouver, ISO, and other styles
34

Chen, Yi Qin. "Aerobic bioremediation of water contaminated with mixture of CAHs and BTEX." Thesis, University of Macau, 2011. http://umaclib3.umac.mo/record=b2546137.

Full text
APA, Harvard, Vancouver, ISO, and other styles
35

Braek, Ahmed Mubarak. "A study of the BTEX/VOCs emission from glycol dehydration units." Thesis, University of Salford, 2003. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.413456.

Full text
APA, Harvard, Vancouver, ISO, and other styles
36

Aüllo, Thomas. "Atténuation naturelle potentielle de BTEX en aquifère de stockage de gaz." Thesis, Pau, 2013. http://www.theses.fr/2013PAUU3018/document.

Full text
Abstract:
La France est dépendante en gaz naturel dont elle importe 98% de sa consommation. Comme pour plusieurs autres pays (Etats-Unis, Canada, Grande Bretagne, Autriche, Allemagne, etc.), le stockage de gaz est principalement réalisé afin de pallier aux variations saisonnières de consommation. Grâce aux spécificités géologiques de notre territoire, ce stockage se fait essentiellement aux niveaux d’aquifères très profonds (-500 à 1000 mètres). Le gaz naturel contient en majorité du méthane mais également des traces d’autres composés tels que les BTEX (Benzène, Toluène, Ethylbenzène et les trois isomères du Xylène) qui sont connus pour leur toxicité. Ces hydrocarbures monoaromatiques peuvent se solubiliser dans l’eau de formation aux niveaux des interfaces eau/gaz. Leur biodégradation est bien moins rapide en anaérobiose qu’en aérobiose mais un potentiel d’atténuation naturelle des BTEX par les communautés microbiennes indigènes a déjà pu être démontré lors de travaux antérieurs. Cependant, bien que de nombreuses études aient été réalisées sur le sujet, les voies de dégradation anaérobie ne sont que partiellement connues et les connaissances concernant les microorganismes impliqués sont réduites, voire inexistantes. Le développement de biomarqueurs moléculaires in situ doit permettre d’évaluer rapidement le potentiel de dégradation des microorganismes d’un aquifère. Pour atteindre cet objectif, il est indispensable d’acquérir une meilleure compréhension des mécanismes de dégradation et donc, d’isoler les microorganismes impliqués dans la dégradation de ces composés. Au cours de cette étude, des communautés microbiennes provenant d’échantillons d’eau de formation issue de trois aquifères distincts (nommés dans ce travail A, C et D) ont été étudiées à l’aide de trois approches différentes de microbiologie environnementale. L’ensemble de ces résultats ainsi que ceux de la littérature suggèrent l’ubiquité des bactéries sulfato-réductrices à Gram positif tels que les Desulfotomaculum dans les environnements profonds. Les résultats obtenus lors de ce travail de doctorat suggèrent le rôle prépondérant de microorganismes affiliés au genre Desulfotomaculum dans la dégradation des BTEX en aquifères très profonds et représentent une avancée dans la compréhension des phénomènes d’atténuation naturelle des BTEX dans ce type d’environnement
France is dependent on natural gas and imports 98% of its consumption. Like in many other countries (The United States of America, Canada, Great Britain, Austria, Germany, etc.), gas storage is primarily performed to compensate for seasonal variations in consumption. Geological characteristics of our territory allow to store essentially natural gas into deep aquifers (-500 to 1000 meters). Natural gas contains mostly methane, but also traces of other compounds such as BTEX (Benzene, Toluene, Ethylbenzene and the three isomers of Xylene) which are known to be toxic. These mono-aromatic hydrocarbons are soluble in water. Anaerobic biodegradation is much slower than aerobic processes however potential for anaerobic BTEX natural attenuation by indigenous microbial communities has already been shown previously. Although many studies have been done on the topic, the anaerobic degradation pathways are only partially known and the knowledge of microorganisms involved is low or nonexistent. The development of in situ molecular biomarkers will allow rapid evaluation of the potential degradation of aquifer microorganisms. To achieve this goal, a better understanding of the mechanisms of degradation is crucial and requires isolation of microorganisms involved in the degradation of these compounds. In this study, microbial communities sampled from formation waters of three distinct aquifers (named in this work A, C and D) were studied using three different environmental microbiology approaches. All these results and those from the literature suggest the ubiquity of sulfate-reducing bacteria such as Gram positive Desulfotomaculum in deep environments. The results obtained during this PhD suggest the importance of microorganisms related to the genus Desulfotomaculum in BTEX degradation in deep aquifers. This work represents a step forward in understanding the phenomenon of natural attenuation of BTEX in this kind of environment
APA, Harvard, Vancouver, ISO, and other styles
37

Farias, Raquel Studart de. "AvaliaÃÃo de Diferentes EstratÃgias de RemoÃÃo de Btex em CondiÃÃes AnaerÃbias." Universidade Federal do CearÃ, 2013. http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=9967.

Full text
Abstract:
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico
Os compostos benzeno, tolueno, etilbenzeno e os xilenos (BTEX) sÃo os hidrocarbonetos monoaromÃticos que agregam maior risco ao meio ambiente, principalmente devido Ãs caracterÃsticas tÃxicas e carcinogÃnicas. Dentre os mÃtodos usualmente aplicados na remoÃÃo de BTEX em Ãguas contaminadas, o tratamento anaerÃbio tem merecido destaque principalmente em relaÃÃo aos baixos custos. Nesse sentido, buscou-se avaliar diferentes estratÃgias de remoÃÃo de BTEX em condiÃÃes anaerÃbias. Foram realizados ensaios em fluxo contÃnuo em trÃs biorreatores anaerÃbios que foram alimentados com soluÃÃo sintÃtica de BTEX (~ 3 mg.L-1 de cada composto) solubilizados em etanol e operados a 27ÂC. As concentraÃÃes dos BTEX foram determinadas por cromatografia. No biorreator metanogÃnico foram analisadas as seguintes influÃncias: 1) do tempo de detenÃÃo hidrÃulico (TDH) (48 h, 36 h e 24 h); 2) da carga orgÃnica volumÃtrica; 3) da recirculaÃÃo do efluente; 4) e do sistema microaerÃbio. O reator sulfetogÃnico foi operado com um TDH de 48 h e foram testados diferentes razÃes DQO/SO4-2 de aproximadamente 12, 5, 2,5 e estequiomÃtrica- com diferentes cargas orgÃnicas. O reator desnitrificante foi operado tambÃm com um TDH de 48 h nas razÃes DQO/NO3- de aproximadamente 12 e 5. Os reatores avaliados mostraram-se bastante estÃveis durante todas as fases do experimento. Com relaÃÃo à remoÃÃo de BTEX, de uma forma geral, as menores eficiÃncias de remoÃÃo foram encontradas para o benzeno, independente do tipo de aceptor final de elÃtrons, indicando a difÃcil biodegradaÃÃo desse composto sob condiÃÃes anaerÃbias, enquanto que as maiores eficiÃncias foram observadas para os xilenos e o tolueno, chegando a remoÃÃes de atà 90%. Tais valores levam em conta possÃveis interferÃncias de adsorÃÃo e de volatilizaÃÃo. TambÃm foi notado que deve haver uma sinergia entre os distintos compostos, podendo esta exercer um forte efeito sobre as eficiÃncias de remoÃÃo dos BTEX. Comparando-se os trÃs reatores, notou-se que nÃo houve melhora significativa nas eficiÃncias de remoÃÃo dos compostos na presenÃa de nitrato ou sulfato. O reator biolÃgico metanogÃnico forneceu elevadas eficiÃncias na remoÃÃo de DQO, superiores a 80% em mÃdia, para as fases que as concentraÃÃes de substrato estavam altas, produzindo biogÃs (predominantemente na forma de gÃs metano), nÃo acumulando Ãcidos graxos volÃteis, e com alcalinidade suficiente para tamponar o meio em pH neutro. A fase que obteve os melhores resultados de remoÃÃo de BTEX (cerca de 94%) foi a que tinha um sistema microaerÃbio adicionado ao reator metanogÃnico, com eficiÃncias de remoÃÃo de DQO superiores a 85%.
The compounds benzene, toluene, ethylbenzene and xylenes (BTEX) are monoaromatic hydrocarbons compounds which represent a high risk for the environment, mainly due to their toxic and carcinogenic characteristics. Among the methods usually applied for the removal of BTEX from contaminated waters, anaerobic treatment has drawn attention especially because of its low cost. Accordingly, anaerobic biodegradation of BTEX was assessed under methanogenic, denitrifying and sulfidogenic conditions. Assays were performed in three bitstream anaerobic bioreactors that were fed with a synthetic solution of BTEX (~ 3 mg.L-1 of each compound) solubilized in ethanol and operated at 27ÂC. The concentrations of BTEX were determined by chromatography. In methanogenic bioreactor were analyzed the following influences: 1) the The hydraulic retention time (HRT) (48 h, 36 h and 24 h), 2) the shock loading, 3) the effluent recycling , 4) and microaerobic system. The sulfidogenic reactor was operated with a HRT of 48 h with different DQO/SO4-2 ratios of approximately 12, 5, 2.5, and stoichiometric with different organic fillers. The denitrifying reactor was also operated with a HRT of 48 h in the rations DQO/NO3-1 of approximately 12 and 5. The reactors evaluated were quite stable during all phases of the experiment. About BTEX removal, in general, benzene showed the lower removal efficiencies, regardless of the electron acceptor, indicating the difficulty of biodegradation of this compound under anaerobic conditions. The highest removal efficiencies were observed for toluene and xylenes, reaching up to 90% removal. These values take into account possible interferences of adsorption and volatilization. It was also noted that there should be a synergy between the different compounds that could have a strong effect on the removal efficiencies of BTEX. Comparing the three reactors, it was noted that there was significant improvement in the removal efficiency of the compounds in the presence of nitrate or sulfate. The methanogenic reactor showed high COD removal efficiencies higher than 80% on average for the phases with a high substrate concentration, producing biogas (mainly in the form of methane) not accumulating volatile fatty acids, and with enough alkalinity to buffer the medium at neutral pH. The phase that achieved the best results BTEX removal (about 94%) was the one that had a microaerobic system added to methanogenic reactor, with COD removal efficiencies exceeding 85%.
APA, Harvard, Vancouver, ISO, and other styles
38

Poceiro, Carla Duarte. "Caraterização dos níveis BTEX no ar em Estarreja: avaliação de campo." Master's thesis, Universidade de Aveiro, 2012. http://hdl.handle.net/10773/10161.

Full text
Abstract:
Mestrado em Engenharia do Ambiente
A crescente industrialização acoplada ao aumento do tráfego rodoviário tem contribuído para a degradação da qualidade do ar em muitas regiões urbanas e suburbanas portuguesas. A região de Estarreja, onde desde meados do séc. XX se instalou um dos maiores complexos de indústria química de base não foi exceção, merecendo atenção especial desde que foram criadas as primeiras comissões de gestão do ar. Durante a década de 80, iniciou-se a monitorização da qualidade do ar nesta região, mas apenas os poluentes clássicos foram contemplados. Atualmente, face a uma maior preocupação com a degradação do ambiente atmosférico, outros poluentes se revelam preocupantes, como por exemplo, compostos orgânicos voláteis, em particular os BTEX. O trabalho aqui apresentado pretende dar um contributo para um melhor conhecimento da qualidade do ar na região de Estarreja, tendo por isso identificado como principal objetivo a caraterização dos níveis de BTEX na atmosfera da região envolvente do Parque Industrial de Estarreja até uma distância de cerca de 5 km e relacionar os níveis observados nos diferentes recetores com potenciais fontes na região. Para tal, foram realizadas cinco campanhas com duração semanal envolvendo 32 locais de amostragem distribuídos num círculo de ~5 km de raio. As campanhas envolveram a amostragem simultânea das concentrações de NO2 e COV’s por métodos de medição passivos. Os valores obtidos revelam que o tolueno foi a espécie de COV’s, que na generalidade, apresentou níveis mais elevados em todas as campanhas. A elevada razão tolueno/benzeno indicia que se está perante uma zona fortemente influenciada pelas emissões do sector industrial, sendo que a razão xilenos/benzeno aponta para que esta zona também seja influenciada por transporte de poluentes de outras regiões. As elevadas correlações existentes entre os xilenos e o etilbenzeno apontam uma fonte comum na área em oposição ao que se observa para o tolueno e benzeno. A análise do PEC (Concentração Equivalente em Propileno) revela que os COV’s de origem biogénica apresentam um potencial de formação de ozono superior ao dos BTEX.
A strong and growing industrialization coupled with increased traffic, has contributed to the degradation of air quality in many urban and suburban Portuguese areas. In the region of Estarreja, where since the century XX has settled the largest complex of basic chemical industry, was no exception, requiring special attention since there was created the first air management commissions. During the 80's, air quality started to be monitored in this region, but only the classics pollutants were included. Currently facing an increasing concern for environmental atmospheric degradation, other pollutants are revealed concerned, for example, volatile organic compounds (VOC´s), particularly BTEX. The work presented here, aims to contribute to a better understanding of air quality in the region of Estarreja, and has therefore identified as main goal the characterization of BTEX levels in the atmosphere, in the region surrounding the Estarreja Industrial Park, to a distance of about 5 km and relate the levels observed in the different receptors with potential sources in the region. To this end, there were performed five campaigns with weekly duration, involving 32 sampling locations, distributed in a circle of ~ 5 km radius. The campaigns involved simultaneous measurement of the concentrations of NO2 and VOC´s, using passive measurement methods. The values obtained show that the toluene was the kind of VOC´s, which in general, showed higher levels in all campaigns. The high ratio toluene/benzene indicate that arises in an area heavily influenced by emissions from industry, the reason being that xylene/benzene suggests that this region is also influenced by transport of pollutants from other regions. The high correlations between the xylenes and ethylbenzene indicate a common source in the area as opposed to what is observed for toluene and benzene. The analysis of the PEC (Propylene Equivalent Concentration) reveals that the biogenic VOC´s presents a potential for ozone formation greater than the BTEX.
APA, Harvard, Vancouver, ISO, and other styles
39

Farias, Raquel Studart. "Avaliação de diferentes estratégias de remoção de BTEX em condições anaeróbias." reponame:Repositório Institucional da UFC, 2013. http://www.repositorio.ufc.br/handle/riufc/5829.

Full text
Abstract:
FARIAS, R. S. Avaliação de diferentes estratégias de remoção de BTEX em condições anaeróbias. 2013. 116 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2013.
Submitted by Marlene Sousa (mmarlene@ufc.br) on 2013-09-16T17:45:00Z No. of bitstreams: 1 2013_dis_rsfarias.pdf: 2208959 bytes, checksum: 50fee00d74f6d943b66059e7e8d71037 (MD5)
Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2013-09-17T17:10:57Z (GMT) No. of bitstreams: 1 2013_dis_rsfarias.pdf: 2208959 bytes, checksum: 50fee00d74f6d943b66059e7e8d71037 (MD5)
Made available in DSpace on 2013-09-17T17:10:57Z (GMT). No. of bitstreams: 1 2013_dis_rsfarias.pdf: 2208959 bytes, checksum: 50fee00d74f6d943b66059e7e8d71037 (MD5) Previous issue date: 2013-03-18
The compounds benzene, toluene, ethylbenzene and xylenes (BTEX) are monoaromatic hydrocarbons compounds which represent a high risk for the environment, mainly due to their toxic and carcinogenic characteristics. Among the methods usually applied for the removal of BTEX from contaminated waters, anaerobic treatment has drawn attention especially because of its low cost. Accordingly, anaerobic biodegradation of BTEX was assessed under methanogenic, denitrifying and sulfidogenic conditions. Assays were performed in three bitstream anaerobic bioreactors that were fed with a synthetic solution of BTEX (~ 3 mg.L-1 of each compound) solubilized in ethanol and operated at 27°C. The concentrations of BTEX were determined by chromatography. In methanogenic bioreactor were analyzed the following influences: 1) the The hydraulic retention time (HRT) (48 h, 36 h and 24 h), 2) the shock loading, 3) the effluent recycling , 4) and microaerobic system. The sulfidogenic reactor was operated with a HRT of 48 h with different DQO/SO4-2 ratios of approximately 12, 5, 2.5, and stoichiometric with different organic fillers. The denitrifying reactor was also operated with a HRT of 48 h in the rations DQO/NO3-1 of approximately 12 and 5. The reactors evaluated were quite stable during all phases of the experiment. About BTEX removal, in general, benzene showed the lower removal efficiencies, regardless of the electron acceptor, indicating the difficulty of biodegradation of this compound under anaerobic conditions. The highest removal efficiencies were observed for toluene and xylenes, reaching up to 90% removal. These values take into account possible interferences of adsorption and volatilization. It was also noted that there should be a synergy between the different compounds that could have a strong effect on the removal efficiencies of BTEX. Comparing the three reactors, it was noted that there was significant improvement in the removal efficiency of the compounds in the presence of nitrate or sulfate. The methanogenic reactor showed high COD removal efficiencies higher than 80% on average for the phases with a high substrate concentration, producing biogas (mainly in the form of methane) not accumulating volatile fatty acids, and with enough alkalinity to buffer the medium at neutral pH. The phase that achieved the best results BTEX removal (about 94%) was the one that had a microaerobic system added to methanogenic reactor, with COD removal efficiencies exceeding 85%.
Os compostos benzeno, tolueno, etilbenzeno e os xilenos (BTEX) são os hidrocarbonetos monoaromáticos que agregam maior risco ao meio ambiente, principalmente devido às características tóxicas e carcinogênicas. Dentre os métodos usualmente aplicados na remoção de BTEX em águas contaminadas, o tratamento anaeróbio tem merecido destaque principalmente em relação aos baixos custos. Nesse sentido, buscou-se avaliar diferentes estratégias de remoção de BTEX em condições anaeróbias. Foram realizados ensaios em fluxo contínuo em três biorreatores anaeróbios que foram alimentados com solução sintética de BTEX (~ 3 mg.L-1 de cada composto) solubilizados em etanol e operados a 27ºC. As concentrações dos BTEX foram determinadas por cromatografia. No biorreator metanogênico foram analisadas as seguintes influências: 1) do tempo de detenção hidráulico (TDH) (48 h, 36 h e 24 h); 2) da carga orgânica volumétrica; 3) da recirculação do efluente; 4) e do sistema microaeróbio. O reator sulfetogênico foi operado com um TDH de 48 h e foram testados diferentes razões DQO/SO4-2 de aproximadamente 12, 5, 2,5 e estequiométrica- com diferentes cargas orgânicas. O reator desnitrificante foi operado também com um TDH de 48 h nas razões DQO/NO3- de aproximadamente 12 e 5. Os reatores avaliados mostraram-se bastante estáveis durante todas as fases do experimento. Com relação à remoção de BTEX, de uma forma geral, as menores eficiências de remoção foram encontradas para o benzeno, independente do tipo de aceptor final de elétrons, indicando a difícil biodegradação desse composto sob condições anaeróbias, enquanto que as maiores eficiências foram observadas para os xilenos e o tolueno, chegando a remoções de até 90%. Tais valores levam em conta possíveis interferências de adsorção e de volatilização. Também foi notado que deve haver uma sinergia entre os distintos compostos, podendo esta exercer um forte efeito sobre as eficiências de remoção dos BTEX. Comparando-se os três reatores, notou-se que não houve melhora significativa nas eficiências de remoção dos compostos na presença de nitrato ou sulfato. O reator biológico metanogênico forneceu elevadas eficiências na remoção de DQO, superiores a 80% em média, para as fases que as concentrações de substrato estavam altas, produzindo biogás (predominantemente na forma de gás metano), não acumulando ácidos graxos voláteis, e com alcalinidade suficiente para tamponar o meio em pH neutro. A fase que obteve os melhores resultados de remoção de BTEX (cerca de 94%) foi a que tinha um sistema microaeróbio adicionado ao reator metanogênico, com eficiências de remoção de DQO superiores a 85%.
APA, Harvard, Vancouver, ISO, and other styles
40

Gurka, Stephanie. "Charakterisierung und funktionelle Bedeutung der BTLA-HVEM-Interaktion für die Immunantwort." Doctoral thesis, Humboldt-Universität zu Berlin, Mathematisch-Naturwissenschaftliche Fakultät I, 2010. http://dx.doi.org/10.18452/16102.

Full text
Abstract:
Interaktionen zwischen Zellen sowie deren Aktivierung werden im Immunsystem durch verschiedene Zelloberflächenmoleküle reguliert. Inhalt dieser Arbeit war die Untersuchung des kürzlich identifizierten Rezeptor-Ligand-Paares BTLA und HVEM. Zunächst wurden diverse BTLA-spezifische monoklonale Antikörper generiert, mit deren Hilfe erstmals die Lokalisation BTLA-tragender Zellen im Gewebe gezeigt werden konnte. Bei umfassenden Expressionsanalysen fiel auf, dass BTLA auf nahezu allen Leukozytenpopulationen der lymphatischen Organe konstitutiv vorhanden ist, und mit seinem Liganden HVEM koexprimiert wird. Beide Moleküle werden auf verschiedenen Zellpopulationen differenziell exprimiert und aktivierungsabhängig reguliert. Funktionelle Analysen in vitro als auch in vivo ergaben, dass die BTLA-HVEM-Interaktion durch Suppression der T-Zellaktivierung und –proliferation wesentlich zur negativen Regulation der Immunantort beiträgt. Die negative Wirkung von BTLA zeigte sich sowohl bei der Initiation als auch bei bereits fortgeschrittener Aktivierung, unabhängig von der Beteiligung positiver kostimulatorischer Signalwege. Durch Stimulation von T Zellen mit unterschiedlicher BTLA-Oberflächenexpression (verschiedene Subpopulationen oder aus transgenen Mäusen) konnte die strikte Korrelation der negativen Funktion mit der BTLA-Menge auf den Zellen gezeigt werden. Es stellte sich heraus, dass BTLA essentiell für die HVEM-vermittelte Suppression ist und eine wesentliche Beteiligung weiterer HVEM-Interaktionspartner (z.B. CD160) nicht vorliegt. Die Beobachtung von veränderten Lymphozytenpopulationen in BTLA-transgenen Mäusen im Ruhezustand weist zudem auf einen zentralen Beitrag des negativen BTLA-Signals zur Aufrechterhaltung der Homöostase hin. Die ubiquitäre Expression von HVEM und BTLA in Kombination mit der gegenseitigen Modulation beider Interaktionspartner ermöglicht eine flexible Reaktion des Immunsystems auf äußere Einflüsse unter anderem über die negative Regulation durch BTLA
Activation of immune cells is regulated by various cell surface molecules during cell-cell interactions. The aim of this work was the characterization of the recently identified receptor-ligand-pair BTLA and HVEM. Initially, several BTLA-specific monoclonal antibodies were generated. With these antibodies, the localization of BTLA expressing cells in the tissues has been determined for the first time. Further detailed flow cytometric analysis revealed a strong constitutive expression of BTLA on nearly all leukocytes in lymphoid organs. Interestingly, all BTLA-expressing cells co-expressed its ligand HVEM. However, both molecules were differentially expressed on different cell populations in the steady state, but were also regulated in an activation-dependent way. Functional analyses in vitro and in vivo (in an antigen-specific adoptive transfer system) revealed a substantial contribution of the BTLA-HVEM interaction for negative regulation of immune responses by suppressing T cell activation and proliferation. Inhibitory signals of BTLA affect the initial and ongoing activation, irrespective of simultaneous positive signals from other co¬stimulatory pathways. Using wildtype and BTLA-transgenic primary T cells, a strictly linear relationship between the inhibitory function of BTLA and its cell surface levels was observed. The data clearly demonstrate that BTLA expression determined the strength of HVEM-mediated suppression, but also that BTLA is essential for this negative co-stimulation, whereas other HVEM-interaction partners were apparently not involved. Finally, the observed changes in lymphoid cell populations of the BTLA-transgenic mice even in the resting state indicate a prominent role for negative BTLA signals to maintain homeostasis. The ubiquitous expression of HVEM and BTLA together with the reciprocal modulation of both interaction partners supports flexible reaction and regulation of the immune system particularly via the inhibitory function of BTLA.
APA, Harvard, Vancouver, ISO, and other styles
41

Castro, Elton Anderson Santos de. "Estudo teórico da adsorção em aluminossilicatos." reponame:Repositório Institucional da UnB, 2007. http://repositorio.unb.br/handle/10482/1393.

Full text
Abstract:
Tese (doutorado)—Universidade de Brasília, Instituto de Química, 2007.
Submitted by Luis Felipe Souza (luis_felas@globo.com) on 2008-12-10T17:05:47Z No. of bitstreams: 1 Tese_2007_EltonCastro.pdf: 4223477 bytes, checksum: 02cdcad1f8f69eda7377b3a116a1dae9 (MD5)
Approved for entry into archive by Georgia Fernandes(georgia@bce.unb.br) on 2009-03-03T19:18:19Z (GMT) No. of bitstreams: 1 Tese_2007_EltonCastro.pdf: 4223477 bytes, checksum: 02cdcad1f8f69eda7377b3a116a1dae9 (MD5)
Made available in DSpace on 2009-03-03T19:18:19Z (GMT). No. of bitstreams: 1 Tese_2007_EltonCastro.pdf: 4223477 bytes, checksum: 02cdcad1f8f69eda7377b3a116a1dae9 (MD5)
Foram realizados cálculos de mecânica molecular, semi-empíricos e abinitio para o estudo de sistemas baseados em caulinita. As posições e freqüências dos hidrogênios foram estudadas na estrutura da caulinita. As posições dos hidrogênios são polêmicas, principalmente os hidrogênios entre as folhas octaédrica e tetraédrica. Também estudou-se a interação deste argilomineral com os hidrocarbonetos monoaromáticos benzeno, tolueno, etilbenzeno, o-xileno e pxileno, bem como com os metais pesados Cd2+, Cu2+, Zn2+, Hg2+ e Ni2+. A caulinita é conhecida pela sua capacidade adsorvente para moléculas orgânicas e metais pesados, sendo importante em técnicas de remediação ambiental. Modelos de aglomerados com 1, 2 e 3 unidades (Al2Si2O9H4) foram usados para estudar o desempenho dos conjuntos de base. A geometria da caulinita foi parcialmente otimizada. Para a otimização da posição do hidrogênio interno empregou-se os métodos RHF/3-21G* e B3LYP/3-21G* com 2 e 3 unidades (Al2Si2O9H4) da caulinita. O método híbrido ONIOM também foi usado com 3 unidades (Al2Si2O9H4) e RHF/3-21G* (ou B3LYP/3-21G*) na camada alta e 12 unidades (Al2Si2O9H4) e o campo de força Dreiding na camada baixa de teoria. Quando comparados com os valores experimentais, os resultados dos cálculos indicamq que o ONIOM2(B3LYP/3-21G*:Dreiding) dá os melhores valores para a distância O-H e ângulos r e l, 0,993Å, 114,8° e 107,6°, respectivamente. Os cálculos de freqüência para os hidrogênios externos e internos com o modelo de 3 unidades (Al2Si2O9H4) mostram que o método RHF/3-21G* se aproxima mais dos resultados experimentais do que os semi-empíricos AM1 e PM3. Estes três métodos apontam para um estiramento da hidroxila interna num número de onda menor do que os das hidroxilas externas. Os espectros teóricos produzidos com o AM1 mostram que há uma redução nas intensidades das bandas de estiramento das hidroxilas externas quando estas interagem com as moléculas BTEX. Também foi encontrado um deslocamento nas bandas de estiramento C-H destas moléculas. As energias de interação, obtidas com os métodos AM1, RHF e B3LYP para os complexos BTEX-Caulinita, sugerem que a adsorção acontece preferencialmente pela superfície hidroxilada da caulinita, ao invés da superfície dos oxigênios. Os métodos de Mülliken e ChelpG indicam que ocorre uma redistribuição nas cargas dos átomos mais próximos das superfícies da caulinita, ficando os hidrogênios mais eletronegativos e os carbonos, mais eletropositivos. Os mapas de potencial eletrostático para os complexos BTEX-Caulinita mostram também uma redistribuição de densidade quando as moléculas interagem com a superfície do argilomineral, corroborando com os resultados de Mülliken e ChelpG. Os orbitais moleculares do benzeno, tolueno e o-xileno adsorvidos pela caulinita sugerem que esta interação acontece através da nuvem p dos compostos aromáticos com as hidroxilas externas da caulinita. Para o estudo dos complexos de metais pesados-caulinita foi usado o ONIOM2(HF/3-21G*:UFF) e ONIOM2(B3LYP/3-21G*:UFF). Para estes modelos da caulinita de 2 camadas, o nível alto de teoria contém um anel da folha octaédrica e um anel da folha tetraédrica mais o cátion. O nível baixo contém 24 unidades (Al2Si2O9H4). A ordem de afinidade encontrada para o resultado B3LYP foi Cu2+>Ni2+>Zn2+>Hg2+>Cd2+, concordando com os resultados experimentais para Cu2+ e Ni2+. O mapa de superfície traçado para a superfície hidroxilada da caulinita sugere que há uma repulsão significativa do metal por esta superfície. _________________________________________________________________________________________ ABSTRACT
Molecular Mechanics, semi-empirical and ab initio calculations were performed in order to study kaolinite based systems. The hydrogen positions and frequencies were studied in the kaolinite structure. Hydrogen positions have been controversial, mainly the hydrogen species between octahedral and tetrahedral sheets. It has also studied the interaction of this clay mineral with the monoaromatic hydrocarbons benzene, toluene, ethylbenzene, o-xylene and pxylene, as well as the interaction with heavy metals Cd2+, Cu2+, Zn2+, Hg2+ and Ni2+. The adsorbent capacity of kaolinite for organic molecules and heavy metals are of main interest on environmental remediation techniques. Cluster models with 1, 2 and 3 units (Al2Si2O9H4) were used to study the basis set performance. The kaolinite geometry was partially optimized. RHF/3-21G* and B3LYP/3-21G* methods with 2 and 3 units (Al2Si2O9H4) of kaolinite were used for optimization of internal hydrogen positions. The hybrid method ONIOM was also used with 3 units (Al2Si2O9H4) and RHF/3-21G* (or B3LYP/3-21G*) on the high layer and with 12 units (Al2Si2O9H4), and Dreiding force field for the low layer theory. Hybrid method results indicate that ONIOM2(B3LYP/3-21G*:Dreiding) gives the best values for OH distance and r and l angles, 0,993Å, 114,8° and 107,6°, respectively, when compared to the experimental values. Frequency calculations, for the external and internal hydrogens with 3 units (Al2Si2O9H4) model, show that RHF/3-21G* approach results are closer to the experimental than AM1 and PM3 semi-empirical methods. These three methods have a internal hydroxyl stretching frequency at wave number smaller than the one of the external hydroxyls. Theoretical spectra produced with AM1 show a reduction in intensities of external hydroxyl stretching bands of kaolinite, when these interact with BTEX molecules. It was also found a displacement on C-H stretching bands of these molecules. Interaction energies obtained with AM1, RHF and B3LYP methods, for BTEX-Kaolinite complexes, suggest that the adsorption occurs preferentially by kaolinite hydroxyl surfaces, instead of kaolinite oxygen surfaces. Mülliken and ChelpG methods indicate that there is charge redistribution on BTEX atoms that are near kaolinite surfaces. These hydrogens become more eletronegatives and the carbons more eletropositives. Eletrostatic potential map for complexes BTEX-Kaolinite show that there is charge redistribution when the molecules interact with clay mineral surfaces, in agreement to the Mülliken and ChelpG results. Benzene, toluene and o-xylene molecular orbitals, when adsorbed on kaolinite, suggest that this interaction is through the p clouds of aromatic compounds with kaolinite external hydroxyls. Complexes heavy metals-kaolinite study was achieved using ONIOM2(HF/3-21G*:UFF) and ONIOM2(B3LYP/3-21G*:UFF) for the kaolinite 2 layers model. The high level of theory has one ring of octaedrical sheet and one ring of tetraedrical sheet plus cation. The low level they contain 24 units(Al2Si2O9H4). The affinity order found for B3LYP result was Cu2+>Ni2+>Zn2+>Hg2+>Cd2+, which is in agreement to the experimental data for Cu2+ and Ni2+. The surface map plotted for kaolinite hydroxyl surface suggests a significant metal repulsion from this surface.
APA, Harvard, Vancouver, ISO, and other styles
42

Weitz, Hedda Johanna. "Construction and characterisation of lux-marked bacteria as biosensors." Thesis, University of Aberdeen, 2000. http://digitool.abdn.ac.uk/R?func=search-advanced-go&find_code1=WSN&request1=AAIU602049.

Full text
Abstract:
Many sites world-wide are contaminated with a range of pollutants of environmental concern. Bioremediation has the potential to be a cost-effective and efficient alternative clean-up technology. The success of bioremediation is influenced by both biological and environmental factors. A site, therefore, needs extensive characterisation to determine the extent of contamination and to evaluate the potential for bioremediation. Chemical analysis has traditionally been used to determine pollutant concentrations, but it provides no information about the bioavailability of the pollutants. Bioassays are able to complement chemical analyses by showing the bioavailability and ecotoxico logical effects of pollutants. Bioluminescent bacteria have been adapted as biosensors where the response to environmental stresses is monitored by a reduction in light output. Only metabolically active cells produce light and any substance or environmental condition which impairs cell metabolism and, thus, compromises cellular activity and viability will lead to a reduction in light output. Naturally bioluminescent marine bacteria (e.g. Vibrio fischeri) have been used for ecotoxicity testing, but soil and freshwater bacteria that have been marked with lux genes have several advantages. These genetically modified biosensors do not require high salinity and a neutral pH, and they have environmental relevance. A suite of biosensors has been developed at the University of Aberdeen that responds to a wide range of pollutants. These biosensors have been successfully used for acute ecotoxicity measurements. The research carried out in this study was part of a larger ICI project for the assessment and management of bioremediation of a BTEX contaminated site. The aim of this study was to develop a lux-marked biosensor based on a BTEX-degrader. None of the existing biosensors are known to be degraders. Environmental isolates from the ICI site that were able to degrade BTEX were characterised and assessed for their suitability for lux-marking. An appropriate isolate was selected for lux-marking, but the marking was not successful. It was concluded that there are several problems associated with obtaining suitable isolates in pure culture from a site. The enrichment, isolation, identification and characterisation of isolates is laborious and time-consuming, and the lack of characterisation of the isolates can complicate the Iwc-marking attempts. Selecting a well-characterised bacterium for lux-marking avoids these problems. Therefore, Pseudomonas putida FI was selected as the bacterium for lux-marking as a biosensor in this study. It was selected because it is a toluene-degrader and the degradative genes are located on the chromosome. P. putida FI also has environmental relevance for the ICI site. P. putida FI and P. putida FI06 (an isogenic mutant of P. putida FI) were lux-marked with the plasmid pUCD607, and P. putida FI and FI06 pUCD607 were characterised. Characterisation of P. putida FI and FI06 pUCD607 suggested that pUCD607 was not stable even under selective conditions due to segregational instability. This study, therefore, concluded that the plasmid pUCD607 is not appropriate for lux-marking bacteria as biosensors. P. putida FI was lux-marked with the mini-Tn5 luxCDABE transposon and P. putida FI Tn5 luxCDABE was characterised. The integration of the mini-Tn5 luxCDABE cassette did not affect growth of P. putida FI Tn5 luxCDABE and luminescence levels were higher than in P. putida FI pUCD607. P. putida FI Tn5 luxCDABE was also stable in the absence of selective pressure over time. This study, therefore, concluded that the mini-TnJ luxCDABE transposon is appropriate for lux-marking bacteria as biosensors.
APA, Harvard, Vancouver, ISO, and other styles
43

Brunel, Simon. "Immunothérapie du cancer par administration d’anticorps monoclonaux anti-HVEM ou anti-ICOS chez la souris humanisée : potentiel thérapeutique et effets immunologiques." Thesis, Paris 6, 2017. http://www.theses.fr/2017PA066215.

Full text
Abstract:
Un nouveau couple de récepteurs de co-signalisation (BTLA/HVEM) a récemment été proposé comme un acteur important dans l’échappement tumoral. L'expression d’HVEM a été identifiée dans la plupart des cancers. Son niveau expression est inversement corrélé avec la survie des patients. L'expression d’HVEM par des cellules tumorales pourrait inhiber la réponse immunitaire à travers BTLA exprimé par les lymphocytes T.Ainsi, dans notre travail, des anticorps monoclonaux (mAb) ciblant HVEM ont été évalués dans un modèle de souris NSG greffées avec des lymphocytes T et des tumeurs humaines. Nous avons tout d’abord caractérisé un clone anti-HVEM avec une forte affinité in vitro. Le clone choisi pour notre étude a montré sa capacité à favoriser l’activation des lymphocytes T humains in vivo, attesté par une aggravation des symptômes et de la mortalité associée au transfert de PBMC humains chez la souris. L’effet anti tumoral observé en l’absence de transfert adoptif était renforcé en présence de lymphocytes T, suggérant un effet additif de l’anticorps sur la tumeur et les lymphocytes T. Une diminution des lymphocytes T régulateurs et une augmentation de la prolifération des lymphocytes T CD8+ dans la tumeur était parfois associée à ce retard de croissance.En reproduisant un environnement partiellement humain chez la souris NSG, nous avons pu évaluer l'effet thérapeutique d’un mAb anti-HVEM dans le développement de deux types de tumeurs humaines et son impact sur le système immunitaire humain. Nos résultats indiquent qu’HVEM, de par son expression par la tumeur et les lymphocytes T, pourrait être une piste judicieuse pour l’immunothérapie du cancer
A new pair of co-signaling receptors (BTLA / HVEM) has recently been proposed as an important actor in tumor escapement. HVEM expression has been identified in wild type of cancers. Its expression level is inversely correlated with patient survival. Expression of HVEM by tumor cells could inhibit the immune response through BTLA expressed by T lymphocytes.Thus, in our work, monoclonal antibodies (mAb) targeting HVEM were evaluated in a model of NSG mice grafted with human T cells and tumors. We first characterized an anti-HVEM clone with high affinity in vitro. The clone selected for our study showed its ability to promote activation of human T lymphocytes in vivo as evidenced by worsening symptoms and mortality associated with human PBMC transfer in mice. The anti-tumor effect observed in the absence of adoptive transfer was enhanced in the presence of T lymphocytes, suggesting an additive effect of the antibody on the tumor and T lymphocytes. A decrease in regulatory T lymphocytes and an increase in the proliferation of CD8 + T lymphocytes in the tumor was sometimes associated with this growth retardation.By reproducing a partially human environment in NSG mice, we were able to evaluate the therapeutic effect of an anti-HVEM mAb in the development of two types of human tumors and its impact on the human immune system. Our results indicate that HVEM, by its expression by the tumor and the T lymphocytes, could be a judicious track for the immunotherapy of the cancer
APA, Harvard, Vancouver, ISO, and other styles
44

Santos, Lívia Martins dos 1986. "Desenvolvimento de instrumentação e método para a determinação de hidrocarbonetos voláteis em amostras de solo empregando espectroscopia no infravermelho próximo." [s.n.], 2015. http://repositorio.unicamp.br/jspui/handle/REPOSIP/250576.

Full text
Abstract:
Orientador: Jarbas José Rodrigues Rohwedder
Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química
Made available in DSpace on 2018-08-27T15:32:58Z (GMT). No. of bitstreams: 1 Santos_LiviaMartinsdos_D.pdf: 6212654 bytes, checksum: f20eb97ce2aae510654340b401468dd2 (MD5) Previous issue date: 2015
Resumo: A contaminação de solos oriundos de derrames de compostos derivados do petróleo é um problema que representa riscos ao meio ambiente e a população. Dentre os constituintes do petróleo, os BTEX são os mais tóxicos. O uso da espectroscopia no infravermelho próximo (NIR) foi empregado como uma ferramenta analítica visando a determinação de BTEX em amostras de solo. À um espectrofotômetro construído no laboratório foi adaptado uma célula de medida, uma célula de amostra e uma válvula esfera responsável pela conexão entre essas duas células. Uma bomba de vácuo foi adaptada ao instrumento visando facilitar o enriquecimento da fase vapor dos hidrocarbonetos voláteis na célula de medida, a qual operou com uma pressão de 29,0 inHg abaixo da pressão do laboratório (APL). Os espectros obtidos da fase vapor contendo os hidrocarbonetos aromáticos apresentaram sobreposição de bandas de absorção. Desta forma, foi necessária a construção de modelos de calibração multivariados empregando Regressão por Mínimos Quadrados Parciais (PLS). Os resultados do melhor modelo de regressão obtidos a melhores condições experimentais mostraram que os valores de RMSECV foram de 12,4 mg kg-1, 47,3 mg kg-1, 72,4 mg kg-1 e 58,6 mg kg-1, respectivamente, para benzeno, tolueno, etilbenzeno e xilenos. Esses valores estão de acordo com os valores orientadores para solo da CETESB de 2005, com exceção para o benzeno que encontra-se acima do valor permitido. Para cada tipo de solo é necessário a construção de modelos de calibração, pois a composição do solo influencia na determinação dos hidrocarbonetos
Abstract: The contamination of soils due to petroleum compounds spills is a problem that represents risks to environment and population. Among petroleum constituents, the volatile aromatic hydrocarbons known as BTEX are toxic. This study aims to evaluate the use of near infrared spectroscopy as an analytical tool for determination of volatile hydrocarbons in soil samples. Spectra were obtained in a spectrophotometer built in the laboratory. It is also part of the instrument, a measuring cell with 540 mm of optical path, a sample cell and a valve which allows connection between the two cells. A vacuum pump was adapted to the instrument in order to facilitate enrichment of the vapor phase of the volatile hydrocarbons in the measuring cell, which operated at a pressure of 29.0 inHg below of the laboratory pressure (BLP). Spectra of the vapor phase containing aromatic hydrocarbons exhibited overlapping of absorption bands. Thus, it was necessary to construct multivariate calibration models using Partial Least Squares Regression (PLS). The results obtained for the calibration model provided values of RMSECV of 12.4 mg Kg¬-1, 47.3 mg Kg¬-1, 72.4 mg Kg¬-1 and 58.6 mg Kg¬-1 for benzene, toluene, ethylbenzene and xylenes, respectively. These values are in agreement with the 2005 CETESB guiding values for soil, except for benzene that is above the allowed value. For each type of soil, it was needed to build calibration models because soil composition affects the determination of hydrocarbons. The developed method is promising and may be used as a screening method to determine the occurrence of contamination in soils by BTEX
Doutorado
Quimica Analitica
Doutora em Ciências
APA, Harvard, Vancouver, ISO, and other styles
45

Fontes, Laiane de Moura 1987. "Fases extratoras para a análise direta de contaminantes orgânicos e inorgânicos em água." [s.n.], 2015. http://repositorio.unicamp.br/jspui/handle/REPOSIP/250559.

Full text
Abstract:
Orientador: Ivo Milton Raimundo Júnior
Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química
Made available in DSpace on 2018-08-27T23:35:46Z (GMT). No. of bitstreams: 1 Fontes_LaianedeMoura_D.pdf: 2914385 bytes, checksum: 3a68971b696f9f31967f1132ab348427 (MD5) Previous issue date: 2015
Resumo: Este trabalho descreve o desenvolvimento de diferentes fases extratoras para a determinação de hidrocarbonetos aromáticos e de íons metálicos em água. Para o desenvolvimento das fases extratoras de polidimetilsiloxano e nanotubos de carbono (PDMS-NTC), os nanotubos foram tratados com ácido nítrico, octadecilamina e hipoclorito de sódio. Este último produziu grupos carboxílicos na superfície do nanomaterial, aumentando sua afinidade por hidrocarbonetos aromáticos. A fase extratora foi preparada pela dispersão dos NTC no PDMS e, depois de pronta, inserida num frasco preenchido com as soluções aquosas dos analitos. Após 60 minutos sob agitação, a fase extratora foi removida da solução, seca e inserida em um sistema de medidas, empregando-se um espectrofotômetro FT-NIR. A fase extratora com NTC oxidados com NaOCl possibilitou um aumento da capacidade de extração de 40% e 20% para tolueno e benzeno, respectivamente. No segundo momento, foram desenvolvidas membranas poliméricas plastificadas utilizando os reagentes complexantes Br-PADAP e TAN para a determinação de cobre e chumbo em água por espectroscopia de emissão óptica com plasma induzido por laser (LIBS). As membranas de PVC não forneceram resultados satisfatórios como fase extratora, pois a homogeneidade e estabilidade da superfície das membranas não puderam ser estabelecidas de maneira satisfatória. Papel de filtro analítico foi utilizado como fase extratora para a pré-concentração de íons cobre e chumbo em meio aquoso de forma eficiente, superando as desvantagens das medidas diretas de líquidos por LIBS. A capacidade de adsorção do papel de filtro foi favorecida pela utilização de soluções básicas, principalmente, entre pH 8,0 e 9,0. O tempo de extração foi de 30 minutos para cobre e 60 minutos para chumbo. Os limites de detecção encontrados foram de 0,22 e 0,53 mg L-1 para cobre e chumbo, respectivamente. Não foi observada interferência dos íons Ni (II), Zn (II), Cd (II) e Fe(III), tampouco influência da força iônica. O método proposto foi utilizado para a determinação de cobre e chumbo em amostra de água de torneira enriquecida em três níveis de concentrações. Recuperações na faixa de 98,8% - 114,3% foram obtidas indicando que a determinação direta de íons cobre e chumbo em amostras aquosas pela técnica LIBS utilizando papel de filtro como fase extratora apresenta potencial para a análise de amostras reais
Abstract: This work describes the development of extraction phases for determination of aromatic hydrocarbons and metal ions in water. For development of the phase based on polydimethilsiloxane and carbon nanotubes (PDMS-NTC), carbon nanotubes were previously functionalized with nitric acid, octadecylamine and sodium hypochlorite. The latter oxidizing agent produced carboxyl groups on the surface of the nanomaterial, increasing its affinity for aromatic hydrocarbons. The extraction phase was prepared by dispersing the functionalized NTC in PDMS, which was polymerized to form cylindrical monoliths. Extractions were performed by immersing the monolith in a flask filled with the aqueous solutions of analytes, containing 2.0 mol L-1 NaCl. After an extraction time of 60 min under constant stirring, the monolith was removed from the flask, dried and inserted in the measuring cell of the FT-NIR spectrophotometer. The extraction phase containing NTC oxidized by sodium hypochlorite allow an increase of the sensitivity of 40% and 20% for toluene and benzene, respectively. In the second part, plasticized polymeric membranes containing Br-PADAP or TAN as complexing reagents were developed for determination of lead and copper in water by laser induced breakdown spectroscopy (LIBS). The PVC membranes did not provide satisfactory results, as the homogeneity and the stability of the membrane could not be attained. Analytical filter paper was then employed as an extraction phase to efficiently pre-concentrate lead and copper ions from aqueous solution, circumventing the disadvantages of direct measurements of liquid phase by LIBS. The sorption capacity of the filter paper was enhanced in basic solutions, mainly within pH 8.0 and 9.0. The ideal extraction time for Cu(II) was 30 minutes and 60 minutes for Pb(II). The detection limits were estimated as 0.22 and 0.53 mg L-1 for Cu(II) and Pb(II), respectively. Interference of Ni (II), Zn (II), Cd (II) and Fe(II) ions were not observed, as well as the influence of the ionic strength. The proposed method was employed for determination of cooper and lead in tap water fortified at three concentrations levels. Recoveries in the range from 98.8% to 114.3% were obtained, indicating that direct determination of these ions in aqueous samples by the LIBS using filter paper as an extraction phase has a potential for analysis of aqueous samples
Doutorado
Quimica Analitica
Doutora em Ciências
APA, Harvard, Vancouver, ISO, and other styles
46

Evangelista, Zuzilene da Silva. "Estudo da remo??o de compostos org?nicos, benzeno e tolueno, em solu??o aquosa por processo oxidativo avan?ado do tipo Fenton." Universidade Federal do Rio Grande do Norte, 2009. http://repositorio.ufrn.br:8080/jspui/handle/123456789/15792.

Full text
Abstract:
Made available in DSpace on 2014-12-17T15:01:23Z (GMT). No. of bitstreams: 1 ZuzileneSE_DISSERT.pdf: 1395431 bytes, checksum: 1be063abe68213c4ae7025f93618fa6d (MD5) Previous issue date: 2009-12-01
Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior
The oil and petrochemical industry is responsable to generate a large amount of waste and wastewater. Among some efluents, is possible find the benzene, toluene, ethilbenze and isomers of xilenes compounds, known as BTEX. These compounds are very volatily, toxic for environment and potencially cancerigenous in man. Oxidative advanced processes, OAP, are unconventional waste treatment, wich may be apply on treatment and remotion this compounds. Fenton is a type of OAPs, wich uses the Fenton s reactant, hydrogen peroxide and ferrous salt, to promove the organic degradation. While the Photo-Fenton type uses the Fenton s reactant plus UV radiation (ultraviolet). These two types of OAP, according to literature, may be apply on BTEX complex system. This project consists on the consideration of the utilization of technologies Fenton and Photo-Fenton in aqueous solution in concentration of 100 ppm of BTEX, each, on simulation of condition near of petrochemical effluents. Different reactors were used for each type of OAP. For the analyticals results of amount of remotion were used the SPME technique (solid phase microextraction) for extraction in gaseous phase of these analytes and the gas chromatography/mass espectrometry The arrangement mechanical of Photo-Fenton system has been shown big loss by volatilization of these compounds. The Fenton system has been shown capable of degradate benzene and toluene compounds, with massic percentage of remotion near the 99%.
A ind?stria de petr?leo e petroqu?mica em geral ? respons?vel por gerar uma grande quantidade de res?duos e efluentes qu?micos. Dentre alguns efluentes, ? poss?vel encontrar os compostos benzeno, tolueno, etilbenzeno e is?meros de xilenos, conhecidos como BTEX. Esses compostos s?o bastante vol?teis, t?xicos ao meio ambiente e potencialmente causadores de c?ncer no ser humano. Processos oxidativos avan?ados, POAs, s?o tecnologias n?o convencionais de tratamento de efluente, os quais podem ser aplicados no tratamento e remo??o desses compostos. Fenton ? um tipo de POA, o qual utiliza o reagente de Fenton, per?xido de hidrog?nio e sais de ferro, para promover a oxida??o de org?nicos. Enquanto que o tipo Foto-Fenton utiliza-se dos reagentes de Fenton acrescido de radia??o UV (ultra violeta). Esses dois tipos de POA, segundo a literatura, podem ser aplicados a sistemas compostos de BTEX. O presente trabalho consiste na avalia??o da utiliza??o das tecnologias Fenton e Foto-Fenton em solu??es aquosas de concentra??o de 100 ppm de BTEX, cada, simulando-se uma condi??o aproximada de efluente petroqu?mico. Foram utilizados reatores distintos para cada tipo de POA. Para as respostas anal?ticas de quantidade de remo??o foram utilizadas as t?cnicas SPME (solid phase microextraction) para extra??o em fase gasosa desses analitos e a cromatografia gasosa/espetrometria de massas. O arranjo mec?nico do sistema Foto-Fenton mostrou grandes perdas por volatiliza??o desses compostos. O sistema Fenton mostrou-se capaz de degradar os compostos benzeno e tolueno, com percentagens m?ssicas de remo??o na ordem de 99%.
APA, Harvard, Vancouver, ISO, and other styles
47

Bezerra, Paula Gimenez. "Contaminação de águas subterrâneas por BTEX na bacia do Rio Lucaia, Salvador, Bahia." http://www.pospetro.geo.ufba.br/dissertacoes/DISSERTA_P%20BEZERRA.pdf, 2011. http://www.pospetro.geo.ufba.br/dissertacoes/DISSERTA_P%20BEZERRA.pdf.

Full text
Abstract:
Karina Santos Garcia - Co-orientadora
Submitted by Hora Fontes Nadja Maria (pospetro@ufba.br) on 2012-11-12T18:29:40Z No. of bitstreams: 1 DISSERTA_P BEZERRA.pdf: 4642516 bytes, checksum: 80a02cde7041f02a85b3b3204fffda61 (MD5)
Made available in DSpace on 2012-11-12T18:29:41Z (GMT). No. of bitstreams: 1 DISSERTA_P BEZERRA.pdf: 4642516 bytes, checksum: 80a02cde7041f02a85b3b3204fffda61 (MD5) Previous issue date: 2011-04-13
Capes; Fapesb
Com o objetivo de se determinar os compostos voláteis BTEX em águas subterrâneas de postos de gasolina, foi implantado o método de determinação de compostos voláteis por purge and trap e espectrometria de cromatografia de massa (GC-MS), EPA 8260C e 5030C. A validação do método foi realizada através do estudo de seletividade, linearidade, sensibilidade, exatidão, precisão, limite de detecção (LD), limite de quantificação (LQ) e robustez. A curva de calibração varia de 2 a 200 μg.L -1 , com valores de recuperação dentro de um intervalo 70 a 120%, com precisão de 20%. Para se investigar a contaminação do aquífero da bacia do Rio Lucaia, Salvador, Bahia, por compostos derivados de petróleo devido a vazamentos de tanques combustíveis, foi determinada em amostras de águas subterrâneas, as concentrações de benzeno, tolueno, etilbenzeno e xilenos (BTEX), sulfato nitrato e ferro (II). A concentração de BTEX variou de 0,2-185,7 µg/L nas águas subterrâneas e as concentrações de sulfato, nitrato e ferro (II) foram correlacionados com os níveis de BTEX e sua degradação natural. Apenas em dois pontos foram observados os níveis de BTEX muito acima do permitido pelo CONAMA, as outras foram abaixo do LD ou não foram detectadas. Uma segunda coleta foi realizada, verificando-se a redução do teor de BTEX nos pontos amostrais da Bacia do rio Lucaia em até 82%. Os valores de nitrato, sulfato e ferro (II) foram relacionados nas duas campanhas observando-se a provável degradação natural dos compostos tendo como aceptores preferenciais o nitrato e o ferro (III), bem como a não dispersão da contaminação em níveis críticos para a população. O trabalho apresentado faz parte do projeto “Contaminação de Águas Subterrâneas por Derivados de Petróleo e Etanol oriundos de Postos de Distribuição na Região Metropolitana de Salvador: Subsídios para a Remediação Ambiental.” Aprovado no Edital 05/2007 pelo termo de outorga FAPESB – UFBA nº 8657 sobre os auspício do Núcleo de Estudos Ambientais do Instituto de Geociências da Universidade Federal da Bahia.
Salvador
APA, Harvard, Vancouver, ISO, and other styles
48

CARVALHO, Marilda Nascimento. "Processo de Remoção de Compostos Btex e Fenol Por Adsorção Multicomponente Em Argilas Organicamente Modificadas." Universidade Federal de Pernambuco, 2011. https://repositorio.ufpe.br/handle/123456789/11882.

Full text
Abstract:
Submitted by Eduarda Figueiredo (eduarda.ffigueiredo@ufpe.br) on 2015-03-11T13:01:47Z No. of bitstreams: 2 TESE_Marilda Nascimento Carvalho_BC.pdf: 2374659 bytes, checksum: 6206ceeb790a2faaa57e74fdae5877af (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Made available in DSpace on 2015-03-11T13:01:47Z (GMT). No. of bitstreams: 2 TESE_Marilda Nascimento Carvalho_BC.pdf: 2374659 bytes, checksum: 6206ceeb790a2faaa57e74fdae5877af (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2011-02-17
A contaminação da água por compostos orgânicos tóxicos é uma das maiores preocupações ambientais e tem aumentado o interesse na busca de adsorventes eficientes para a remoção desses compostos. A adsorção utilizando argilas constitui uma das tecnologias de aplicação crescentes empregadas no tratamento secundário de efluentes contaminados por compostos orgânicos de origem na indústria de petróleo. Este trabalho investigou um processo de adsorção dos compostos orgânicos benzeno, tolueno, etilbenzeno, xilenos (BTEX) e do fenol presentes em soluções aquosas em baixas concentrações, até 20 mg/L, por meio de uma argila esmectítica (chocolate) de origem do estado da Paraíba, no nordeste do Brasil, visando colaborar com tecnologias de caráter sustentável, para a indústria de petróleo e petroquímica. A argila organofílica foi sintetizada a partir do sal quaternário (SQA) cloreto de hexadeciltrimetilamônio na concentração de 150% da capacidade de troca catiônica (CTC) da argila, a qual promoveu o aumento do espaçamento basal da estrutura cristalina do argilomineral de 14,73 Å para 22,08 Å. Procedeu-se à avaliação de sistemas de adsorção multicomponente, em regime descontínuo, considerando as abordagens cinéticas e de equilíbrios. Os teores dos componentes BTEX e fenol foram quantificados por cromatografia líquida de alta eficiência (CLAE). Os resultados experimentais ajustaram-se bem ao modelo de equilíbrio combinado de Langmuir-Freundlich e revelaram capacidades máximas de adsorção entre 1,27mg/g (tolueno) a 8,28mg/g (fenol) e cinéticas de equilíbrio em torno de 30 minutos. Parâmetros relacionados à heterogeneidade superficial da argila indicaram a existência de sítios ativos específicos. As afinidades de adsorção de BTEX e de fenol pela argila organofílica no sistema multicomponente apresentaram-se na ordem decrescente: etilbenzeno > xilenos > tolueno > fenol > benzeno. Estas afinidades estiveram relacionadas ao tamanho das moléculas dos aromáticos. As eficiências de remoção obtidas variaram em torno de 55% e 90%.
APA, Harvard, Vancouver, ISO, and other styles
49

Bravo-Lopez, Ana Ivonne. "The fate of petrol oxygenates and BTEX compounds in the vadose zone." Thesis, Imperial College London, 2004. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.409144.

Full text
APA, Harvard, Vancouver, ISO, and other styles
50

Dörr, Fabiane. "Consórcios degradadores de BTEX: isolamento, caracterização e avaliação do potencial de degradação." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/87/87131/tde-11042012-152743/.

Full text
Abstract:
Amostras de água subterrânea provenientes de uma área industrial contaminada por hidrocarbonetos monoaromáticos foram utilizadas para a obtenção de bactérias degradadoras de BTEX (benzeno, tolueno, etilbenzeno e isômeros de xileno), com o intuito de realizar sua identificação, caracterização e avaliação do potencial de degradação. Foram estudados os perfis de crescimento dos consórcios de bactérias enriquecidos em BTEX, isoladamente e com diferentes substratos. Apenas parte das cepas isoladas apresentaram capacidade de crescimento quando expostas individualmente aos compostos em que foram previamente adaptadas. Foram identificadas, por análises de ácidos graxos e seqüenciamento do DNAr 16S, as espécies Stenotrophomonas maltophilia, Serratia marcescens, Burkholderia cepacia, Enterobacter sp., Bacillus cereus e Bacillus tropicalis.
Groundwater samples from an industrial area contaminated with monoaromatic hydrocarbons were used to obtain BTEX (benzene, toluene, ethylbenzene and xylene isomers) degrading bacteria, for the purpose of do their identification, characterization and evaluate their degradation potential. The growth rate of bacterial consortia enriched on BTEX was studied, individually and with different substrates. Just some of the strains isolated showed growth capacity when individually exposed to the compounds in which they were previously adapted. Were identified, by fatty acid analysis and 16S rDNA sequencing, the species Stenotrophomonas maltophilia, Serratia marcescens, Burkholderia cepacia, Enterobacter sp., Bacillus cereus and Bacillus tropicalis.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography