Academic literature on the topic 'Bioimpedancemeter'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Bioimpedancemeter.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Bioimpedancemeter"

1

Lavrishcheva, Juliia V., and Aleksandr A. Jakovenko. "Ways to optimize the assessment of lean body mass in hemodialysis patients." Urologicheskie vedomosti 9, no. 1 (May 24, 2019): 23–28. http://dx.doi.org/10.17816/uroved9123-28.

Full text
Abstract:
The aim. To conduct a comparative analysis of the effectiveness of methods for assessing lean body mass in haemodialysis patients. Patients and methods. A total of 317 patients receiving treatment with programmatic bicarbonate haemodialysis in 9 haemodialysis centers in 5 regions of the European part of the Russian Federation were examined for 8.2 ± 5.1 years, among them 171 women and 146 men, the average age was 57.1 ± 11.3 years. Dual-energy X-ray absorptiometry and bioimpedancemetry were used to assess lean body mass. Results. The results of determining the total lean body mass obtained from the results of dual-energy X-ray absorptiometry and bioimpedancemetry were compared using the Bland-Altman method. The correlation coefficient between the indicators was r = 0.994, p < 0.0001, delta (M ± σ) was –0.48 ± 0.91 kg, CI 95% (–0.71)–(–0.26) kg. Conclusion. Dual-energy X-ray absorptiometry has no significant advantages compared with bioimpedancemetry when evaluating lean body mass in haemodialysis patients.
APA, Harvard, Vancouver, ISO, and other styles
2

Coeffier, M., M. Gaté, A. Rimbert, A. Petit, V. Folope, S. Grigioni, P. Déchelotte, and N. Achamrah. "Does bioimpedancemetry accurately assess muscle mass in severely malnourished patients?" Clinical Nutrition ESPEN 40 (December 2020): 483–84. http://dx.doi.org/10.1016/j.clnesp.2020.09.235.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Tornuev, Yu V., E. V. Koldysheva, G. A. Lapiy, O. P. Molodykh, S. M. Balakhnin, G. M. Bushmanova, D. E. Semenov, and V. K. Preobrazhenskaya. "Bioimpedancemetry in the Diagnostics of Inflammatory Process in the Mammary Gland." Bulletin of Experimental Biology and Medicine 156, no. 3 (January 2014): 381–83. http://dx.doi.org/10.1007/s10517-014-2354-y.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Khablova, Anastasiya A., Galina N. Bondar’, Pavel F. Kiku, Natal’ya S. Tumanova, Valentina N. Rasskazova, and Anna V. Sukhova. "Assessment of the health of medical students." Health Care of the Russian Federation 64, no. 3 (July 1, 2020): 132–38. http://dx.doi.org/10.46563/0044-197x-2020-64-3-132-138.

Full text
Abstract:
Human health, in addition to social and spiritual well-being, is determined by its physical condition, which reflects the functional capabilities of the body, features of physical development and ensures working capacity in any activity, including academic workload, which is extremely important for students in higher educational institutions. The purpose of the study is to assess the health status of students at the School of Biomedicine of the Far Eastern Federal University. Material and methods. The health status of 184 medical students (147 young women and 37 young men) was assessed using a sociological survey (questionnaire) and a study of the component composition of the body using bioimpedancemetry. Results. The low physical activity, detected in 68% of students and bad habits (smoking tobacco) have been established to negatively affect students’ health. Among smokers, 75% of students live in dormitories on the university campus. According to the results of bioimpedancemetry, significant deviations from the age norm were noted in terms of body mass index (BMI) (50% of cases) and fat mass (FM) (71% of cases). Significant gender differences in the individual components of the body were not identified. Discussion. The most aggressive factors that significantly affect the health of students are unbalanced nutrition, lack of compliance with the regime of study and rest, lack of sleep and stay in the fresh air, lack of physical activity, lack of motivation for a healthy lifestyle. Significant deviations in BMI and FM, identified by bioimpedancemetry, indicate the risks of developing arterial hypertension, metabolic syndrome, and nutritional status disorders. Medical students need to give recommendations for increasing motor activity and changing diet. Conclusion. The results of the study can be used in the future to determine the functional state of students and develop preventive measures to preserve the health of medical students.
APA, Harvard, Vancouver, ISO, and other styles
5

Stepanov, Yu M., T. Y. Boiko, O. V. Sorochan, M. V. Stoikevych, and A. S. Shkaredna. "Bioimpedancemetry in Evaluating Nutritional Status of Patients with Chronic Inflammatory Bowel Diseases." GASTROENTEROLOGY, no. 2.56 (June 4, 2015): 59–66. http://dx.doi.org/10.22141/2308-2097.2.56.2015.81498.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Cosoli, Gloria, Lorenzo Scalise, Graziano Cerri, Paola Russo, Gerardo Tricarico, and Enrico Primo Tomasini. "Bioimpedancemetry for the assessment of periodontal tissue inflammation: a numerical feasibility study." Computer Methods in Biomechanics and Biomedical Engineering 20, no. 6 (February 13, 2017): 682–90. http://dx.doi.org/10.1080/10255842.2017.1291804.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Mamoshin, A. V., A. V. Borsukov, Yu V. Ivanov, N. P. Istomin, and N. V. Mokshina. "MINIINVASIVE TECHNIQUES OF ACUTE DESTRUCTIVE PANCREATITIS DIAGNOSTIC AND TREATMENT." Journal of Clinical Practice 7, no. 2 (June 15, 2016): 32–39. http://dx.doi.org/10.17816/clinpract7232-39.

Full text
Abstract:
In the article the modern controlled miniinvasive techniques of acute destructive pancreatitis diagnostic and treatment and its complications are discussed. Perspective miniinvasive techniques as many-frequent bioimpedancemetry and crystallography are described. Different controlled miniinvasive interventions were used in the particular sequence in dependence on clinico-morphological form of pathological process. Endocavital ultrasound research is the perspective area in the development of miniinvasive techniques at the destructive pancreatitis.
APA, Harvard, Vancouver, ISO, and other styles
8

Smelysheva, L., E. Musikhina, N. Artenyan, G. Kovaleva, and G. Kuznetsov. "BODY COMPONENT COMPOSITION AND STRESS-INDUCED FEATURES OF LEPTIN SECRETION IN FEMALES WITH VARIOUS BODY MASS INDEX." Human Sport Medicine 20, no. 2 (July 14, 2020): 80–89. http://dx.doi.org/10.14529/hsm200210.

Full text
Abstract:
Aim. The article aims to study the dynamics of the adipose tissue hormone leptin in healthy females with different body component composition and body mass index to assess their energy status under stress. Materials and methods. Based on anthropometry and bioimpedancemetry, three groups of girls were formed: the first group included girls with a BMI of less than 18.5 kg/m2, body mass deficiency (BMD), the second – from 18.5 to 24.9 kg/m2, normal body mass (NBM), the third – with a BMI of more than 24.9 kg/m2, which corresponds to overweight (OvBM). The body component composition was determined by bioimpedancemetry. Plasma leptin concentration was evaluated by enzyme-linked immunosorbent assay both in normal conditions and during emotional stress. Results. In the selected subgroups, a significant difference in the body component composition was found with an increase in the series of BMD → NBM → OvBM. When assessing the level of metabolic processes by the magnitude of the phase angle, it was found that 3.41% of females with BMD showed signs of increased protein catabolism. The stress-induced dynamics of the hormone leptin was evaluated. In normal conditions, the concentration of leptin in blood plasma positively correlated with BMI and depended on the component composition of the body. Conclusion. In persons with BMD, the adipose tissue hormone leptin had a negative dynamics under stress conditions, which was an adequate adaptive physiological response to stress. Females with BMD had a significantly high positive dynamics of leptin, while girls with OvBM did not have significant changes in its concentrations, which can be explained by the development of leptin resistance.
APA, Harvard, Vancouver, ISO, and other styles
9

Mamoshin, A. V., A. V. Borsukov, and Y. V. Ivanov. "Diagnostic possibilities of investigation methods in acute destructive pancreatitis." Medical alphabet, no. 17 (September 23, 2020): 26–30. http://dx.doi.org/10.33667/2078-5631-2020-17-26-30.

Full text
Abstract:
The article demonstrates the diagnostic effectiveness of clinical, laboratory and instrumental methods for the differentiation of clinical and morphological forms of acute destructive pancreatitis. The importance of such promising methods as minimally invasive multi-frequency bioimpedancemetry of the pathological focus, the crystallographic study of aspirate performed during fine-needle diagnostic puncture and differential diagnosis of exudative complications of acute destructive pancreatitis is shown. The results obtained determine the necessity of a comprehensive approach with the expansion of the diagnostic algorithm by using fine-needle diagnostic puncture. A comprehensive assessment of diagnostic methods significance can increase the effectiveness of differential diagnosis of clinical and morphological forms of destructive pancreatitis, thereby allowing to timely determinate the tactical position in the treatment of this category of patients.
APA, Harvard, Vancouver, ISO, and other styles
10

Nodimar, Céline, Karine Moreau, Christian Combe, and Philippe Chauveau. "NUTRITIONAL STATUS AND BODY COMPOSITION IN PERITONEAL DIALYSIS PATIENTS: RELEVANCE OF BIOIMPEDANCEMETRY (BCM®) FOR LONGITUDINAL MONITORING." Kidney Research and Clinical Practice 31, no. 2 (June 2012): A95. http://dx.doi.org/10.1016/j.krcp.2012.04.633.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Bioimpedancemeter"

1

Ткачук, Богдан Владимирович. "Определение уровня гидратации пациентов, получающих лечение методом программного гемодиализа." Thesis, НТУ "ХПИ", 2017. http://repository.kpi.kharkov.ua/handle/KhPI-Press/29316.

Full text
Abstract:
Диссертация на соискание ученой степени кандидата технических наук по специальности 05.11.17 – биологические и медицинские приборы и системы. – Национальный технический университет "Харьковский политехнический институт", Харьков, 2017. Диссертационная работа посвящена решению одной из актуальных научно-технических задач современного гемодиализа – контроля состояния гидратации пациента и разработке метода для своевременной остановки процедуры ультрафильтрации при достижении пациентом "сухого веса". В работе проведено анализ современных биофизических представлений про распределение и перемещение жидкостей в организме пациента, что позволило выявить высокий уровень сложности и многофакторности гидравлических процессов и установить необходимость создания математических моделей перемещения жидкостей и критерия остановки процедуры при достижении пациентом "сухого веса". Впервые получена математическая модель перемещения жидкости в организме пациента при ультрафильтрации, на основании теории неравновесной термодинамики, что позволило выявить взаимную функциональную зависимость наполнения жидкостных секторов при процедуре программного гемодиализа. Усовершенствована электрофизическая модель процессов в организме пациента при ультрафильтрации для метода биоимпедансометрии, за счет разделения жидкостных секторов, что позволило использовать его для определения состояния гидратации пациента при процедуре программного гемодиализа. По результатам теоретических исследований выбран параметр гематокрита, который характеризует состояние наполнения сосудистого русла, что дало возможность разделить объем внеклеточной жидкости на составляющие. Разработан метод определения "сухого веса", критерием в котором является распределение объема внеклеточной жидкости на две составляющие интерстициальную жидкость и плазму крови и сравнении значений объемов удаленного ультрафильтрата в этих составляющих во время гемодиализа. Разработанный на основе результатов моделирования метод определения "сухого веса" пациентов, позволил повысить достоверность определения момента достижения уровня нормогидратации пациентов при программном гемодиализе на (11-16) %. Разработана структурная схема системы для определения "сухого веса", которая позволяет объединить воедино серийно выпускаемые аппарат "искусственная почка", прибор биоимпедансометр и ПК, что дает возможность реализовать алгоритмические решения и обеспечить работу системы, без разработки дополнительных аппаратных средств. На основе клинических исследований и испытаний разработаны основные медико-технические требования для выбора или проектирования приборов биоимпедансометров, а также созданы практические рекомендации для применения метода определения "сухого веса" пациентов в гемодиализных клиниках. Сопоставление результатов проведенных клинических исследований с данными полученными с помощью традиционных методик, при ультрафильтрации, подтвердили эффективность разработанных моделей и метода для определения "сухого веса" пациента при программном гемодиализе. Основные результаты работы нашли внедрение в лечебный процесс отделения амбулаторного хронического гемодиализа №10, Харьковского областного клинического центра урологии и нефрологии им. В.И. Шаповала; в учебный процесс на кафедре промышленной и биомедицинской электроники НТУ "ХПИ"; при разработке нового варианта измерителя биоимпеданса человека в НТУ Украины "КПИ им. Игоря Сикорского".
The thesis for the degree of candidate of technical sciences, specialty 05.11.17 – biological and medical devices and systems. – National Technical University "Kharkiv Polytechnic Institute", Kharkiv, 2017. The thesis is devoted to one of actual scientific and technical problems of modern hemodialysis - monitoring of patient hydration and developing methods for timely stopping ultrafiltration procedure when reaching the patient "dry weight". The method of determining the "dry weight" criterion which is the distribution of extracellular fluid volume into two components interstitial fluid and blood plasma volume and value compared to the removed ultrafiltrate in these components during hemodialysis developed. The mathematical model of fluid movement in the patient received the first time. electro and model processes in the patient with ultrafiltration method for bioimpedancemetry improved. Based on simulation method for determining the "dry weight" patients developed first. It is possible to determine authenticity hung reaching state normohidratotsiyi at program hemodialysis. Also practical guidelines for the application of this method in clinics created.
APA, Harvard, Vancouver, ISO, and other styles
2

Ткачук, Богдан Володимирович. "Визначення рівня гідратації пацієнтів, які отримують лікування методом програмного гемодіалізу." Thesis, НТУ "ХПІ", 2017. http://repository.kpi.kharkov.ua/handle/KhPI-Press/29298.

Full text
Abstract:
Дисертація на здобуття наукового ступеня кандидата технічних наук за спеціальністю 05.11.17 – біологічні та медичні прилади і системи. – Національний технічний університет "Харківський політехнічний інститут", Харків, 2017. Дисертаційну роботу присвячено вирішенню однієї з актуальних науково-технічних задач сучасного гемодіалізу – контролю стану гідратації пацієнта та розробці методу для своєчасної зупинки процедури ультрафільтрації при досягненні пацієнтом "сухої ваги". Розроблено метод визначення "сухої ваги", критерієм у якому є розподіл об’єму позаклітинної рідини на дві складові інтерстиціальну рідину і плазму крові та порівнянні значень об'ємів видаленого ультрафільтрату у цих складових під час гемодіалізу. Вперше отримано математичну модель переміщення рідини в організмі пацієнта та удосконалено електрофізичну модель процесів в організмі пацієнта при ультрафільтрації для методу біоімпедансометрії. Вперше розроблено на основі результатів моделювання метод визначення "сухої ваги" пацієнтів, що дозволило підвищити достовірність визначення моменту досягнення стану нормогідратоції при програмному гемодіалізі на (11-16) %. Також створено практичні рекомендації для застосування даного методу у гемодіалізних клініках.
The thesis for the degree of candidate of technical sciences, specialty 05.11.17 – biological and medical devices and systems. – National Technical University "Kharkiv Polytechnic Institute", Kharkiv, 2017. The thesis is devoted to one of actual scientific and technical problems of modern hemodialysis - monitoring of patient hydration and developing methods for timely stopping ultrafiltration procedure when reaching the patient "dry weight". The method of determining the "dry weight" criterion which is the distribution of extracellular fluid volume into two components interstitial fluid and blood plasma volume and value compared to the removed ultrafiltrate in these components during hemodialysis developed. The mathematical model of fluid movement in the patient received the first time. electro and model processes in the patient with ultrafiltration method for bioimpedancemetry improved. Based on simulation method for determining the "dry weight" patients developed first. It is possible to determine authenticity hung reaching state normohidratotsiyi at program hemodialysis. Also practical guidelines for the application of this method in clinics created.
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Bioimpedancemeter"

1

Jamin, Antoine, Jean-Baptiste Fasquel, Mehdi Lhommeau, Eva Cornet, Sophie Abadie-Lacourtoisie, Samir Henni, and Georges Leftheriotis. "An Aggregation Plateform for IoT-Based Healthcare: Illustration for Bioimpedancemetry, Temperature and Fatigue Level Monitoring." In Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering, 125–30. Cham: Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-51234-1_20.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography