Academic literature on the topic 'Artificial implants'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Artificial implants.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Artificial implants"
Marchewka, M., and J. Zubrzycki. "Construction aspects of intraocular artificial lenses." Journal of Physics: Conference Series 2412, no. 1 (December 1, 2022): 012011. http://dx.doi.org/10.1088/1742-6596/2412/1/012011.
Full textBowers, Christian A., Jaron H. McMullin, Cameron Brimley, Linsey Etherington, Faizi A. Siddiqi, and Jay Riva-Cambrin. "Minimizing bone gaps when using custom pediatric cranial implants is associated with implant success." Journal of Neurosurgery: Pediatrics 16, no. 4 (October 2015): 439–44. http://dx.doi.org/10.3171/2015.2.peds14536.
Full textLambert, Lorraine. "Artificial Hair Implants." International Society of Hair Restoration Surgery 6, no. 5 (September 1996): 9.2–9. http://dx.doi.org/10.33589/6.5.9b.
Full textInoue, Takashi. "The development of an artificial protein for periodontal application." Impact 2018, no. 3 (June 15, 2018): 79–81. http://dx.doi.org/10.21820/23987073.2018.3.79.
Full textMohammadi, Bijan, Zahra Abdoli, and Ehsan Anbarzadeh. "Investigation of the Effect of Abutment Angle Tolerance on the Stress Created in the Fixture and Screw in Dental Implants Using Finite Element Analysis." Journal of Biomimetics, Biomaterials and Biomedical Engineering 51 (June 14, 2021): 63–76. http://dx.doi.org/10.4028/www.scientific.net/jbbbe.51.63.
Full textWalter, Peter. "Implants for artificial vision." Expert Review of Ophthalmology 4, no. 5 (October 2009): 515–23. http://dx.doi.org/10.1586/eop.09.42.
Full textEarar, Kamel, Ioan Sirbu, Ctristian Onisor, and Elena Luca. "Oral Rehabilitation on Implants and Introduction of Pathogenic Mechanisms in Relation to Oral Implants - Sugar Diabetes." Revista de Chimie 70, no. 10 (November 15, 2019): 3750–52. http://dx.doi.org/10.37358/rc.19.10.7639.
Full textCasesnoves, Francisco. "Nonlinear Comparative Optimization for Biomaterials Wear in Artificial Implant Technology." Key Engineering Materials 800 (April 2019): 52–59. http://dx.doi.org/10.4028/www.scientific.net/kem.800.52.
Full textRomanos, Georgios E., Gerard A. Fischer, Zaid T. Rahman, and Rafael Delgado-Ruiz. "Spectrometric Analysis of the Wear from Metallic and Ceramic Dental Implants following Insertion: An In Vitro Study." Materials 15, no. 3 (February 4, 2022): 1200. http://dx.doi.org/10.3390/ma15031200.
Full textRoman, Călin Rareş, and Lidia Adriana Sorcoi. "Preliminary Studies Regarding the Behaviour of New Titanium Implants." Materials Science Forum 672 (January 2011): 233–36. http://dx.doi.org/10.4028/www.scientific.net/msf.672.233.
Full textDissertations / Theses on the topic "Artificial implants"
Swamy, Amit. "Development of laboratory spine with artificial muscles." Thesis, University of Hull, 2007. http://hydra.hull.ac.uk/resources/hull:780.
Full textZeng, Shengyue. "Bonnet polishing of cobalt chrome alloys for artificial implants." Thesis, University of Huddersfield, 2014. http://eprints.hud.ac.uk/id/eprint/19751/.
Full textSantos, Alex Eugênio dos [UNESP]. "Desenvolvimento de parafuso de interferência bioabsorvível para cirurgia de joelho em PLDL (poli ácido lático) e compósito PLDL + βTCP (beta trifosfato de cálcio)." Universidade Estadual Paulista (UNESP), 2015. http://hdl.handle.net/11449/124038.
Full textO parafuso de interferência é o dispositivo de fixação mais usados em cirurgias de reconstrução ligamentar de joelho. O uso dos polímeros bioabsorvíveis está sendo cada vez mais utilizados nesta aplicação, devido suas vantagens relacionadas à excelente biocompatibilidade, bioabsorção, integração do enxerto/osso e também facilidade na revisão cirúrgica. O presente estudo tem por objetivo tem por objetivo o desenvolvimento de um parafuso de interferência bioabsorvível fabricado através do processo de injeção em dois polímeros bioabsorvíveis: PLDL (Poli L-D-ácido lático) e um compósito de PLDL+30% TCP (β Trifosfato de Cálcio). Para o desenvolvimento do projeto do produto foi usado um programa de análise estrutural por elementos finitos, de forma a obter a melhor geometria do encaixe de ferramenta. Através dos estudos de simulação por elementos finitos foi possível selecionar a geometria com maior resistência mecânica levando em conta o esforço de torção e além disso foi possível analisar a influência de furos transversais nas tensões mecânicas geradas pelos esforços de torção. Após a definição da melhor geometria, foram fabricadas amostras dos parafusos com os dois polímeros selecionados, os quais foram esterilizados por ETO (Óxido de etileno). Foram realizados testes mecânicos de torque inserção e torque de ruptura. A resistência mecânica do parafuso foi avaliada através da comparação entre os valores do torque de inserção comparando-se com o torque máximo de ruptura. Para contribuir o estudo foi executado teste de degradação in vitro, durante um período de 180 dias, onde foi avaliada a perda de massa dos implantes, resistência mecânica e queda do peso molecular dos implantes. Logo foi possível avaliar o compartamento mecânico dos implantes em degradação comparando-os com os requerimentos da aplicação. Pode-se observar que a degradação molecular do implante ao longo dos...
The interference screw is the fixation device most selected for Knee ligament reconstruction surgeries. The use of Bioabsorbable polymers in interference screws for this application is increasing due it has advantages like excellent biocompatibility, bioabsorption, good integration between graft / bone and also facility in the surgical revision. The aims of the present study were to develop a bioabsorbable interference screw manufactured by the injection moulding process with two distinct polymeric materials: PLDL, Poly(L,DL-Latic acid) and a composite PLDL + 30% TCP (β Tricalcium phosphate). A program for structural analysis by finite elements was used in the development of the screw design, in the intend to make the best geometry fit for the tool. Trough the study by finite elements simulation it was possible to chose the geometry with higher mechanical resistance taking in the account the torsion effort and analyse the influence of transversals holes in the mechanical tensions made by the torque efforts. After the definition of the best geometry, samples of the screw were manufactured with the two selected polymers, sterilized with ETO (ethylene oxide). Were performed mechanical tests, insertion test and torque to break. The mechanical strenght of the screw was evaluated through the comparison between the values of insertion torque and maximum rupture. In addition, a in vitro, degradation test was performed over a period of 180 year days. It was observed, the weight loss, mechanical strength of the implants was evaluated, and molecular weight drops of the implants. Therefore it was possible to evaluate the mechanical behavior in degradation and compare with the application requirements. It can be observed that the raise of the molecular degradation of the implant along the months had as result a loss of the mechanical resistance of the screw, ina slowly and gradual way for the PLDL material, yet the composite material (PLDL+TCP)...
Soranz, Filho João Edward [UNESP]. "O uso de implantes orbitários no reparo de cavidades anoftálmicas." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/86305.
Full textConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Universidade Estadual Paulista (UNESP)
Alterações oculares, em especial a perda de volume nas cavidades evisceradas, promovem uma série de modificações ao paciente tanto funcional do órgão quanto psicológica e estética. Uma grande preocupação ao longo do tempo é a procura de um material que possa preencher o volume perdido de forma a dar um maior conforto no ponto de visto psicológico e estético ao paciente. Para contribuir nessa direção, esse trabalho teve como objetivo testar experimentalmente prótese de polietileno granulado de ultra-alto peso molecular, material de baixo custo, em órbitas de coelhos submetidos à evisceração cirúrgica em vários tempos experimentais, onde foram avaliados aspectos macroscópicos e microscópicos e de toxicidade sistêmica do material. Os resultados desse trabalho mostram que o material utilizado no implante de cavidade não apresenta alteração significativa nos parâmetros analisados quando comparados ao grupo controle. Sendo resultados bastante promissores indicando que o implante de polietileno poroso desenvolvido por uma indústria nacional tem alto potencial para se realizar testes em humanos
Ocular changes especially the loss of volume in eviscerated cavities promotes several modifications to patients – organ functioning and psychological and esthetical changes. A material that could replace the lost volume in order to guarantee to patients more psychological and esthetical comfort has long been worryingly searched. Contributing in this direction this work aimed at testing experimentally a prosthesis polyethylene granulate of ultra-high molecular weight made of a low cost material to be implanted in orbit of rabbits through surgical evisceration during several experimental times to assess macroscopic and microscopic aspects of systemic toxicity of the respective material. The results show that the material used for the implant of the prosthesis in the cavity does not present significant alteration in the analysed parameters when compared to the control group. Thus, we point with this study promising results indicating that the porous polyethylene implant developed by a national enterprise presents high potential to be tested in humans
Estambasse, Eduardo Costa [UNESP]. "Análise de materiais para sistemas de fechamento ósseo através da caracterização superficial e comportamento mecânico." Universidade Estadual Paulista (UNESP), 2015. http://hdl.handle.net/11449/132584.
Full textNeste trabalho busca-se observar um estudo de caracterização mecânica em materiais destinados a implantes, a caracterização superficial dos corpos de provas usinados dos três tipos de materiais utilizados nos implantes para fechamento ósseo titânio grau cinco, titânio grau quatro e aço inox 316 L, estes três tipos de materiais são considerados como biomateriais pois possuem todas as propriedades necessárias para reconstrução óssea, e tem provado ser eficiente para implantes. Este estudo se dará através da aplicação detalhada de ensaios de caracterização superficial e propriedades mecânicas. Um estudo da rugosidade dos materiais antes do implante e a determinação do módulo de cisalhamento e elasticidade utilizando um método não destrutivo foram utilizados. Será apresentado uma síntese dos diferentes tipos de fixação e comparados aos resultados dos ensaios nos materiais. Nos materiais usinados em formatos de discos, foram coletadas imagens num mmicroscópio confocal, e foi realizada análise da superfície com a finalidade de obtenção da rugosidade média quadrática de cada material a fim de identificar a melhor condição de superfície. Uma revisão de literatura fundamentará o estudo proposto
In this work the aim is to observe a mechanical characterization study materials for implants, the surface characteristics of the machined test samples of three types of materials used in bone implants for closing five grade titanium, and titanium grade for stainless steel 316 L, there three types of materials are considered as biomaterials because they posses the necessary properties for bone reconstruction, and has proven to be efficient for implants. This study will be through the detailed application of surface characterization and mechanical properties testing. A study of the roughness of the material before implantation and determining the shear modulus and elasticity using a non-destructive method were used. A summary of different types of fasteners and compared to the test results on the materials will be presented. In machined materials dise formats, images were collected on a confocal microscope, and surface analysis was performed for the purpose of obtaining the mean roughness and mean square surface roughness in order to identify the best surface condition. A literature review reasons or the proposed study
Santos, Alex Eugênio dos. "Desenvolvimento de parafuso de interferência bioabsorvível para cirurgia de joelho em PLDL (poli ácido lático) e compósito PLDL + βTCP (beta trifosfato de cálcio) /." Bauru, 2015. http://hdl.handle.net/11449/124038.
Full textBanca: Bento Rodrigues de Pontes Junior
Banca: Arthur Alves Fiocchi
Resumo: O parafuso de interferência é o dispositivo de fixação mais usados em cirurgias de reconstrução ligamentar de joelho. O uso dos polímeros bioabsorvíveis está sendo cada vez mais utilizados nesta aplicação, devido suas vantagens relacionadas à excelente biocompatibilidade, bioabsorção, integração do enxerto/osso e também facilidade na revisão cirúrgica. O presente estudo tem por objetivo tem por objetivo o desenvolvimento de um parafuso de interferência bioabsorvível fabricado através do processo de injeção em dois polímeros bioabsorvíveis: PLDL (Poli L-D-ácido lático) e um compósito de PLDL+30% TCP (β Trifosfato de Cálcio). Para o desenvolvimento do projeto do produto foi usado um programa de análise estrutural por elementos finitos, de forma a obter a melhor geometria do encaixe de ferramenta. Através dos estudos de simulação por elementos finitos foi possível selecionar a geometria com maior resistência mecânica levando em conta o esforço de torção e além disso foi possível analisar a influência de furos transversais nas tensões mecânicas geradas pelos esforços de torção. Após a definição da melhor geometria, foram fabricadas amostras dos parafusos com os dois polímeros selecionados, os quais foram esterilizados por ETO (Óxido de etileno). Foram realizados testes mecânicos de torque inserção e torque de ruptura. A resistência mecânica do parafuso foi avaliada através da comparação entre os valores do torque de inserção comparando-se com o torque máximo de ruptura. Para contribuir o estudo foi executado teste de degradação in vitro, durante um período de 180 dias, onde foi avaliada a perda de massa dos implantes, resistência mecânica e queda do peso molecular dos implantes. Logo foi possível avaliar o compartamento mecânico dos implantes em degradação comparando-os com os requerimentos da aplicação. Pode-se observar que a degradação molecular do implante ao longo dos...
Abstract: The interference screw is the fixation device most selected for Knee ligament reconstruction surgeries. The use of Bioabsorbable polymers in interference screws for this application is increasing due it has advantages like excellent biocompatibility, bioabsorption, good integration between graft / bone and also facility in the surgical revision. The aims of the present study were to develop a bioabsorbable interference screw manufactured by the injection moulding process with two distinct polymeric materials: PLDL, Poly(L,DL-Latic acid) and a composite PLDL + 30% TCP (β Tricalcium phosphate). A program for structural analysis by finite elements was used in the development of the screw design, in the intend to make the best geometry fit for the tool. Trough the study by finite elements simulation it was possible to chose the geometry with higher mechanical resistance taking in the account the torsion effort and analyse the influence of transversals holes in the mechanical tensions made by the torque efforts. After the definition of the best geometry, samples of the screw were manufactured with the two selected polymers, sterilized with ETO (ethylene oxide). Were performed mechanical tests, insertion test and torque to break. The mechanical strenght of the screw was evaluated through the comparison between the values of insertion torque and maximum rupture. In addition, a "in vitro", degradation test was performed over a period of 180 year days. It was observed, the weight loss, mechanical strength of the implants was evaluated, and molecular weight drops of the implants. Therefore it was possible to evaluate the mechanical behavior in degradation and compare with the application requirements. It can be observed that the raise of the molecular degradation of the implant along the months had as result a loss of the mechanical resistance of the screw, ina slowly and gradual way for the PLDL material, yet the composite material (PLDL+TCP)...
Mestre
Estambasse, Eduardo Costa. "Análise de materiais para sistemas de fechamento ósseo através da caracterização superficial e comportamento mecânico /." Bauru, 2015. http://hdl.handle.net/11449/132584.
Full textBanca: Natal Nerimio Rogone
Banca: Gilberto de Magalhães Bento Gonçalves
Resumo: Neste trabalho busca-se observar um estudo de caracterização mecânica em materiais destinados a implantes, a caracterização superficial dos corpos de provas usinados dos três tipos de materiais utilizados nos implantes para fechamento ósseo titânio grau cinco, titânio grau quatro e aço inox 316 L, estes três tipos de materiais são considerados como biomateriais pois possuem todas as propriedades necessárias para reconstrução óssea, e tem provado ser eficiente para implantes. Este estudo se dará através da aplicação detalhada de ensaios de caracterização superficial e propriedades mecânicas. Um estudo da rugosidade dos materiais antes do implante e a determinação do módulo de cisalhamento e elasticidade utilizando um método não destrutivo foram utilizados. Será apresentado uma síntese dos diferentes tipos de fixação e comparados aos resultados dos ensaios nos materiais. Nos materiais usinados em formatos de discos, foram coletadas imagens num mmicroscópio confocal, e foi realizada análise da superfície com a finalidade de obtenção da rugosidade média quadrática de cada material a fim de identificar a melhor condição de superfície. Uma revisão de literatura fundamentará o estudo proposto
Abstract: In this work the aim is to observe a mechanical characterization study materials for implants, the surface characteristics of the machined test samples of three types of materials used in bone implants for closing five grade titanium, and titanium grade for stainless steel 316 L, there three types of materials are considered as biomaterials because they posses the necessary properties for bone reconstruction, and has proven to be efficient for implants. This study will be through the detailed application of surface characterization and mechanical properties testing. A study of the roughness of the material before implantation and determining the shear modulus and elasticity using a non-destructive method were used. A summary of different types of fasteners and compared to the test results on the materials will be presented. In machined materials dise formats, images were collected on a confocal microscope, and surface analysis was performed for the purpose of obtaining the mean roughness and mean square surface roughness in order to identify the best surface condition. A literature review reasons or the proposed study
Mestre
Sridharan, Srinivasan. "Porous plastic implants for bone ingrowth." Thesis, Georgia Institute of Technology, 1994. http://hdl.handle.net/1853/10101.
Full textSoranz, Filho João Edward. "O uso de implantes orbitários no reparo de cavidades anoftálmicas /." Botucatu : [s.n.], 2011. http://hdl.handle.net/11449/86305.
Full textBanca: Silvana Artioli Schellini
Banca: Cláudia Valeria Seullner Brandão
Resumo: Alterações oculares, em especial a perda de volume nas cavidades evisceradas, promovem uma série de modificações ao paciente tanto funcional do órgão quanto psicológica e estética. Uma grande preocupação ao longo do tempo é a procura de um material que possa preencher o volume perdido de forma a dar um maior conforto no ponto de visto psicológico e estético ao paciente. Para contribuir nessa direção, esse trabalho teve como objetivo testar experimentalmente prótese de polietileno granulado de ultra-alto peso molecular, material de baixo custo, em órbitas de coelhos submetidos à evisceração cirúrgica em vários tempos experimentais, onde foram avaliados aspectos macroscópicos e microscópicos e de toxicidade sistêmica do material. Os resultados desse trabalho mostram que o material utilizado no implante de cavidade não apresenta alteração significativa nos parâmetros analisados quando comparados ao grupo controle. Sendo resultados bastante promissores indicando que o implante de polietileno poroso desenvolvido por uma indústria nacional tem alto potencial para se realizar testes em humanos
Abstract: Ocular changes especially the loss of volume in eviscerated cavities promotes several modifications to patients - organ functioning and psychological and esthetical changes. A material that could replace the lost volume in order to guarantee to patients more psychological and esthetical comfort has long been worryingly searched. Contributing in this direction this work aimed at testing experimentally a prosthesis polyethylene granulate of ultra-high molecular weight made of a low cost material to be implanted in orbit of rabbits through surgical evisceration during several experimental times to assess macroscopic and microscopic aspects of systemic toxicity of the respective material. The results show that the material used for the implant of the prosthesis in the cavity does not present significant alteration in the analysed parameters when compared to the control group. Thus, we point with this study promising results indicating that the porous polyethylene implant developed by a national enterprise presents high potential to be tested in humans
Mestre
Schultz, Nathaniel David. "A comparison of repeated uniaxial tension and compression on bone-like cells over fourteen days." Master's thesis, Mississippi State : Mississippi State University, 2008. http://library.msstate.edu/etd/show.asp?etd=etd-11072008-150852.
Full textBooks on the topic "Artificial implants"
1944-, Williams D. F., ed. Current perspectives on implantable devices: A research annual. London: JAI Press, 1990.
Find full textHunt, Jennie P. Silicone implants: January 1989 through July 1992 : 985 citations. Bethesda, Md: U.S. Dept. of Health and Human Services, Public Health Service, National Institutes of Health, National Library of Medicine, Reference Section, 1992.
Find full textLeopoldina-Symposium (2009 Warnemünde, Rostock, Germany). Intelligent implants in ophthalmology. Edited by Guthoff Rudolf, Schmitz Klaus-Peter, Zrenner Eberhart 1945-, and Universität Rostock. Halle (Saale): Deutsche Akademie der Naturforscher Leopoldina, 2010.
Find full textUnited States. Food and Drug Administration., ed. Breast implants: An information update. Rockville, Md. (5600 Fishers Lane, Rockville 20857): U.S. Food and Drug Administration, 1996.
Find full textFedorov, S. N. Keratoprostheses. Edinburgh: Churchill Livingstone, 1987.
Find full textG, Heimke, ed. Osseo-integrated implants. Boca Raton, Fla: CRC Press, 1990.
Find full textEdwards, Harry W. Waste minimization assessment for manufacturer of surgical implants. Cincinnati, OH: U.S. Environmental Protection Agency, Rsearch and Development, Risk Reduction Engineering Laboratory, 1994.
Find full textLeir, Roger K. The aliens and the scalpel: Scientific proof of extraterrestrial implants in humans. Columbus, NC: Granite Pub., 1998.
Find full textEdwards, Harry W. Waste minimization assessment for manufacturer of surgical implants. Cincinnati, OH: U.S. Environmental Protection Agency, Rsearch and Development, Risk Reduction Engineering Laboratory, 1994.
Find full textPolymeric biomaterials. Utrecht: VSP, 2003.
Find full textBook chapters on the topic "Artificial implants"
Arnold, Bozena. "Alumina: The Artificial Aluminum Oxide." In Rubies and Implants, 53–54. Berlin, Heidelberg: Springer Berlin Heidelberg, 2022. http://dx.doi.org/10.1007/978-3-662-66116-1_18.
Full textArnold, Bozena. "Bauxite and the Path to Artificial Aluminium Oxide." In Rubies and Implants, 55–57. Berlin, Heidelberg: Springer Berlin Heidelberg, 2022. http://dx.doi.org/10.1007/978-3-662-66116-1_19.
Full textKolawole, Funsho Olaitan, Shola Kolade Kolawole, Felix Adebayo Owa, Chioma Ifeyinwa Madueke, and Oluwole Daniel Adigun. "Polymeric Nanocomposites for Artificial Implants." In Hybrid Polymeric Nanocomposites from Agricultural Waste, 321–41. Boca Raton: CRC Press, 2022. http://dx.doi.org/10.1201/9781003170549-16.
Full textGotman, Irena. "Biomechanical and Tribological Aspects of Orthopaedic Implants." In Springer Tracts in Mechanical Engineering, 25–44. Cham: Springer International Publishing, 2020. http://dx.doi.org/10.1007/978-3-030-60124-9_2.
Full textShepperd, J. A. N. "Intradiscal Implants in 1989: Concepts and Possibilities." In The Artificial Disc, 35–38. Berlin, Heidelberg: Springer Berlin Heidelberg, 1991. http://dx.doi.org/10.1007/978-3-642-75197-4_5.
Full textShepperd, J. A. N. "Intervertebral Implants for Fixation and Disc Replacement." In The Artificial Disc, 45–51. Berlin, Heidelberg: Springer Berlin Heidelberg, 1991. http://dx.doi.org/10.1007/978-3-642-75197-4_7.
Full textAbou-Hassan, Ali, Alexandre A. Barros, Noor Buchholz, Dario Carugo, Francesco Clavica, Filipe Mergulhao, and Shaokai Zheng. "Preventing Biofilm Formation and Encrustation on Urinary Implants: (Bio)molecular and Physical Research Approaches." In Urinary Stents, 437–47. Cham: Springer International Publishing, 2022. http://dx.doi.org/10.1007/978-3-031-04484-7_34.
Full textBermejo, Iñigo, Francisco Javier Díez, Paul Govaerts, and Bart Vaerenberg. "A Probabilistic Graphical Model for Tuning Cochlear Implants." In Artificial Intelligence in Medicine, 150–55. Berlin, Heidelberg: Springer Berlin Heidelberg, 2013. http://dx.doi.org/10.1007/978-3-642-38326-7_23.
Full textWillert, H. G. "Failure Modes of Artificial Joint Implants Due to Particulate Implant Material." In Implant Bone Interface, 67–75. London: Springer London, 1990. http://dx.doi.org/10.1007/978-1-4471-1811-4_10.
Full textPal, Subrata. "Dental Implants: Their Design and Manufacture." In Design of Artificial Human Joints & Organs, 75–100. Boston, MA: Springer US, 2013. http://dx.doi.org/10.1007/978-1-4614-6255-2_5.
Full textConference papers on the topic "Artificial implants"
Wang, F. C., Z. M. Jin, and I. J. Udofia. "Elasto-Hydrodynamic Lubrication Modelling of Spherical Metal-on-Metal Artificial Hip Joints." In World Tribology Congress III. ASMEDC, 2005. http://dx.doi.org/10.1115/wtc2005-63556.
Full textPerez Fornos, Angelica, Nils Guinand, Raymond Van de Berg, Maurizio Ranieri, Samuel Cavuscens, Anissa Boutabla, Julie Corre, and Herman Kingma. "Vestibular Implants in Humans: Steps Towards a Clinical Application." In Neural Interfaces and Artificial Senses. València: Fundació Scito, 2021. http://dx.doi.org/10.29363/nanoge.nias.2021.001.
Full textKashi, Ajay, Amit Roy Chowdhury, and Subrata Saha. "Finite Element Analysis of TMJ Implant." In ASME 2009 4th Frontiers in Biomedical Devices Conference. ASMEDC, 2009. http://dx.doi.org/10.1115/biomed2009-83052.
Full textGhose, Smaranjit, Suhrid Datta, Vineet Batta, C. Malathy, and Gayathri M. "Artificial Intelligence based identification of Total Knee Arthroplasty Implants." In 2020 3rd International Conference on Intelligent Sustainable Systems (ICISS). IEEE, 2020. http://dx.doi.org/10.1109/iciss49785.2020.9315956.
Full textWang, Fengcai, and Zhongmin Jin. "Lubrication Modelling of Artificial Hip Joints: From Fluid Film to Boundary Lubrication Regimes." In ASME 7th Biennial Conference on Engineering Systems Design and Analysis. ASMEDC, 2004. http://dx.doi.org/10.1115/esda2004-58077.
Full textChiryatyeva, A. E., D. U. Malaev, K. B. Orazbayeva, A. A. Prokhorikhin, A. R. Tarkova, E. I. Kretov, and A. A. Boykov. "Investigation of artificial materials for development of transcatheter cardiovascular implants." In PROCEEDINGS OF THE ADVANCED MATERIALS WITH HIERARCHICAL STRUCTURE FOR NEW TECHNOLOGIES AND RELIABLE STRUCTURES. Author(s), 2018. http://dx.doi.org/10.1063/1.5083294.
Full textMcGann, Megan E., and Diane R. Wagner. "Fabrication of Cartilage-Bone Specimens for Cartilage Wear Testing." In ASME 2009 Summer Bioengineering Conference. American Society of Mechanical Engineers, 2009. http://dx.doi.org/10.1115/sbc2009-206724.
Full textSivarasu, Sudesh, Sam Prasanna James, and T. Lazar Mathew. "Finite Element Method Oriented Failure Analysis of Medical Implants: Artificial Knee." In ASME 2013 Conference on Frontiers in Medical Devices: Applications of Computer Modeling and Simulation. American Society of Mechanical Engineers, 2013. http://dx.doi.org/10.1115/fmd2013-16145.
Full textGoyal, Rakesh, Charu Khosla, Meenakshi Sood, Kamaljeet Singh, Punam, and Khushdeep Goyal. "A Review on Artificial Intelligence Driven Biomedical Engineering Implants in Healthcare." In 2022 2nd International Conference on Advance Computing and Innovative Technologies in Engineering (ICACITE). IEEE, 2022. http://dx.doi.org/10.1109/icacite53722.2022.9823903.
Full textVaughan, Neil, and Venketesh N. Dubey. "Hip Replacement Simulator for Predicting Dislocation Risk." In ASME 2016 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. American Society of Mechanical Engineers, 2016. http://dx.doi.org/10.1115/detc2016-59286.
Full textReports on the topic "Artificial implants"
SAINI, RAVINDER, AbdulKhaliq Alshadid, and Lujain Aldosari. Investigation on the application of artificial intelligence in prosthodontics. INPLASY - International Platform of Registered Systematic Review and Meta-analysis Protocols, December 2022. http://dx.doi.org/10.37766/inplasy2022.12.0096.
Full text