Dissertations / Theses on the topic 'Adesivi dentinali'

To see the other types of publications on this topic, follow the link: Adesivi dentinali.

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Adesivi dentinali.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Marimoto, Ângela Regina Kimie [UNESP]. "Resistência adesiva de sistemas autocondicionante e convencional frente a diferentes substratos e associação ao laser Nd:YAG: estudo in vitro." Universidade Estadual Paulista (UNESP), 2007. http://hdl.handle.net/11449/89613.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-26Bitstream added on 2014-06-13T20:51:29Z : No. of bitstreams: 1 marimoto_ark_me_sjc.pdf: 390443 bytes, checksum: d76f9139d735bc954e3a1f9a3c6ec8ce (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
A adesão continua a ser um desafio na Odontologia, principalmente em tecidos morfologicamente distintos e valendo-se de sistemas adesivos de mecanismos de ação também distintos. O objetivo deste estudo in vitro foi comparar a resistência adesiva de dois sistemas (autocondicionante e convencional) em dois substratos (esmalte e dentina), associados ou não à tecnologia laser (Nd:YAG). Foram utilizados 120 dentes bovinos, recém-extraídos, embutidos, que tiveram a superfície de esmalte ou dentina exposta por meio de lixas. Uma área de 3mm de diâmetro na região cérvico-vestibular-mediana foi selecionada para adesão, de acordo com os seguintes grupos: a) G1: AF/ esmalte (adesivo autocondicionante em esmalte seguindo especificação do fabricante); b) G2: AF/ dentina (adesivo autocondicionante em dentina seguindo especificação do fabricante); c) G3: AL/ esmalte (adesivo autocondicionante em esmalte + laser Nd:YAG + fotopolimerização); d) G4: AL/ dentina (adesivo autocondicionante em dentina + laser Nd:YAG + fotopolimerização); e) G5: CF/ esmalte (condicionamento ácido + adesivo convencional em esmalte); f) G6: CF/ dentina (condicionamento ácido + adesivo convencional em dentina); g) G7: CL/ esmalte (condicionamento ácido + adesivo convencional em esmalte + laser Nd:YAG + fotopolimerização); h) G8: CL/ dentina (condicionamento ácido + adesivo convencional em dentina + laser Nd:YAG + fotopolimerização). A resina composta Z 250 foi inserida com auxílio de matriz de teflon e fotopolimerizada com luz halógena, seguida da realização do teste de cisalhamento em máquina universal Emic, com carga de100kgf e velocidade de 0,5mm/min. Os valores médios em MPa obtidos para os diferentes grupos foram: G1 (20,291), G2 (14,142), G3 (23,615), G4 (22,235), G5 (20,899), G6 (11,291), G7 (22,102), G8 (15,980). Após aplicação do teste de ANOVA e Tukey 5%, concluiu-se que...
Bonding continues to be a challenge in Dentistry, particularly in morphologically different tissues, and adhesive systems with different action mechanisms are also valid. The aim of this study was to compare the bond strength of two systems (self-etching and conventional) to two substrates (enamel and dentin) either associated with laser technology (Nd:YAG) or not. One hundred and twenty (120) recently extracted, embedded bovine teeth were used, and abrasive papers were used to expose the enamel or dentin surfaces. An area of 3mm in diameter in the cervical-vestibular-median region was selected for bonding, according to the following groups: a) G1: AF/ enamel (self-etching adhesive to enamel in accordance with the manufacturer's specification); b) G2: AF/ dentin (self-etching adhesive to dentin in accordance with the manufacturer's specification); c) G3: AF/ enamel (self-etching adhesive to enamel + laser Nd:YAG + light polymerization ; d) G4: AL/ dentin (self-etching adhesive to dentin + laser Nd:YAG + light polymerization ; e) G5: CF/ enamel (acid etching + conventional adhesive to enamel); f) G6: CF/ dentin (acid etching + conventional adhesive to dentin); g) G7: CL/ enamel (acid etching + conventional adhesive to enamel + laser Nd:YAG + light polymerization ; h) G8: CL/ dentin (acid etching + conventional adhesive to dentin + laser Nd:YAG + light polymerization). Resin composite Z250 was inserted with the aid of a Teflon matrix and light polymerized, followed by the shear test in an EMIC universal machine, with a load of 100 Kgf and speed of 0.5 mm/min. The mean values obtained in Mpa for the different groups were: G1 (20.291), G2 (14.142), G3 (23.615), G4 (22.235), G5 (20.899), G6 (11.291), G7 (22.102), G8 (15.980). After applying the ANOVA and Tukey tests 5%, it was concluded that the application of laser Nd:YAG significantly increased the bond strength under all the experimental... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
2

Martin, Júnior Manoel [UNESP]. "Sistemas adesivos convencional e autocondicionante: análise micromecânica tridimensional da interface dentina-adesivo." Universidade Estadual Paulista (UNESP), 2008. http://hdl.handle.net/11449/105580.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-10-30Bitstream added on 2014-06-13T18:46:01Z : No. of bitstreams: 1 martinjunior_m_dr_araca.pdf: 402142 bytes, checksum: ec08401476b3983abaa71ed519f0d4e8 (MD5)
OBJETIVO: Avaliar a distribuição das tensões na interface dentina-adesivo variando o sistema adesivo, convencional e autocondicionante, através do método dos elementos finitos tridimensional. MATERIAL E MÉTODO: Foram elaborados 4 modelos no programa Solidworks 2007, sendo: Mc - representação de um espécime em dentina (41x41x82 μm) restaurado com resina composta (RC), apresentando camada de adesivo, camada híbrida (CH), TAGs, dentina peri-tubular, dentina intertubular parcialmente desmineralizada, dentina intertubular e prolongamento odontoblástico, simulando a formação da CH segundo o sistema adesivo convencional; Mr - idêntico ao Mc, com ramificações laterais do infiltrado do adesivo; Ma – idêntico ao Mc, sem TAGs, e com “smear plug”, simulando o sistema adesivo autocondicionante; Mat – idêntico ao Ma, com TAGs. Os modelos foram considerados isotrópicos, homogêneos e linearmente elásticos e a análise numérica foi realizada no ANSYS Workbench 10.0 para obtenção da máxima tensão principal (MAX) após aplicação de força de tração de 0,03 N perpendicular à superfície da RC. A base de todos os modelos foi fixada nos eixos x, y e z. RESULTADOS: A MAX foi maior para o sistema convencional. A presença da ramificação lateral aumentou a MAX na CH para o sistema convencional. Os TAGs modificaram a distribuição da MAX na camada de adesivo para o sistema autocondicionante. CONCLUSÃO: A CH para o sistema convencional apresentou maior MAX em comparação ao sistema autocondicionante. A presença das ramificações laterais do adesivo aumentaram a tensão na CH para o sistema convencional.
OBJECTIVE: The aim of this study was to evaluate the stress distribution in the hybrid layer varying the adhesive system (total each and self-etching systems) using three-dimensional finite element analysis (FE). METHODS: 4 FE models (M) were developed in Solidworks 2007: Mc - representation of a specimen of dentin (41x41x82 μm) restored with composite resin (RC), showing the adhesive layer, hybrid layer (HL), TAGs, peri-tubular dentin, intertubular dentin in order to simulate simulating the HL according to the total-etch adhesive system; Mr - similar to Mc, with lateral branches of the adhesive; Ma – similar to Mc, without TAGs and showing the smear plug in order to simulate the environment for the self-ethcing adhesive system; Mat – similar to Ma, with TAGs. The models were considered isotropic, homogeneous and linearly elastic and numerical analysis was performed in ANSYS Workbench 10.0 to obtain the maximum principal stress (MAX) after application of a tension force of 0.03N perpendicular to the surface of the RC. The botton of all models was fixed in x, y and z axis. RESULTS: The highest MAX in HL was observed in the total etching system. The lateral branches increased the MAX in HL. The TAGs had a little influence on the stress distribution in self-ethching system. CONCLUSION: The HL for the total-etch system showed MAX higher in comparison with the self-etch system. The presence of TAGs increased the MAX in the HL for the total-etch system.
APA, Harvard, Vancouver, ISO, and other styles
3

Martin, Júnior Manoel. "Sistemas adesivos convencional e autocondicionante : análise micromecânica tridimensional da interface dentina-adesivo /." Araçatuba : [s.n.], 2008. http://hdl.handle.net/11449/105580.

Full text
Abstract:
Orientador: Eduardo Passos Rocha
Banca: Marco Antonio Luersen
Banca: Renato Herman Sundfeld
Banca: Marcelo Giannini
Banca: Washington Rodrigues Camargo
Resumo: OBJETIVO: Avaliar a distribuição das tensões na interface dentina-adesivo variando o sistema adesivo, convencional e autocondicionante, através do método dos elementos finitos tridimensional. MATERIAL E MÉTODO: Foram elaborados 4 modelos no programa Solidworks 2007, sendo: Mc - representação de um espécime em dentina (41x41x82 μm) restaurado com resina composta (RC), apresentando camada de adesivo, camada híbrida (CH), TAGs, dentina peri-tubular, dentina intertubular parcialmente desmineralizada, dentina intertubular e prolongamento odontoblástico, simulando a formação da CH segundo o sistema adesivo convencional; Mr - idêntico ao Mc, com ramificações laterais do infiltrado do adesivo; Ma - idêntico ao Mc, sem TAGs, e com "smear plug", simulando o sistema adesivo autocondicionante; Mat - idêntico ao Ma, com TAGs. Os modelos foram considerados isotrópicos, homogêneos e linearmente elásticos e a análise numérica foi realizada no ANSYS Workbench 10.0 para obtenção da máxima tensão principal (MAX) após aplicação de força de tração de 0,03 N perpendicular à superfície da RC. A base de todos os modelos foi fixada nos eixos x, y e z. RESULTADOS: A MAX foi maior para o sistema convencional. A presença da ramificação lateral aumentou a MAX na CH para o sistema convencional. Os TAGs modificaram a distribuição da MAX na camada de adesivo para o sistema autocondicionante. CONCLUSÃO: A CH para o sistema convencional apresentou maior MAX em comparação ao sistema autocondicionante. A presença das ramificações laterais do adesivo aumentaram a tensão na CH para o sistema convencional.
Abstract: OBJECTIVE: The aim of this study was to evaluate the stress distribution in the hybrid layer varying the adhesive system (total each and self-etching systems) using three-dimensional finite element analysis (FE). METHODS: 4 FE models (M) were developed in Solidworks 2007: Mc - representation of a specimen of dentin (41x41x82 μm) restored with composite resin (RC), showing the adhesive layer, hybrid layer (HL), TAGs, peri-tubular dentin, intertubular dentin in order to simulate simulating the HL according to the total-etch adhesive system; Mr - similar to Mc, with lateral branches of the adhesive; Ma - similar to Mc, without TAGs and showing the "smear plug" in order to simulate the environment for the self-ethcing adhesive system; Mat - similar to Ma, with TAGs. The models were considered isotropic, homogeneous and linearly elastic and numerical analysis was performed in ANSYS Workbench 10.0 to obtain the maximum principal stress (MAX) after application of a tension force of 0.03N perpendicular to the surface of the RC. The botton of all models was fixed in x, y and z axis. RESULTS: The highest MAX in HL was observed in the total etching system. The lateral branches increased the MAX in HL. The TAGs had a little influence on the stress distribution in self-ethching system. CONCLUSION: The HL for the total-etch system showed MAX higher in comparison with the self-etch system. The presence of TAGs increased the MAX in the HL for the total-etch system.
Doutor
APA, Harvard, Vancouver, ISO, and other styles
4

Angeloni, Valeria. "Rola of collagen cross-linkers on the stability of bonded interface." Doctoral thesis, Università degli studi di Trieste, 2015. http://hdl.handle.net/10077/11800.

Full text
Abstract:
2013/2014
Restorative adhesive dentistry is based on the infiltration of dental adhesive resin within the dentin collagen network creating the hybrid layer. The stability and integrity of collagen fibrils within the hybrid layer are crucial for the maintenance of bond effectiveness over time. The matrix metallo-proteinases enzymes (MMPs), which are endogenous enzymes present in dentin tissue, are claimed to play a key role in affecting the integrity of the hybrid layer causing the hydrolysis and degradation of dentin collagen. The aim of this research project was to evaluate the efficacy of different cross-linking agent in preserving the adhesive/dentin layer. Two water soluble collagen cross-linking agents riboflavin, and the carbodiimide hydrochloride, 1-ethyl-3-[3-dimethylaminopropyl] (EDC) were initially tested, then additional cross-linking agents were included in the study: acrolein, (water soluble), and the N,N'-dicyclohexylcarbodiimide (DCC) (soluble in acetone and ethanol). The concentration of each solution was chosen according to the previous studies: 0.1% riboflavin/wt, 0.3M EDC/wt, 0,01% acrolein/wt, 0.5M DCC/ethanol, 0.5M/acetone. Cross-linkers were associated to different adhesive systems available on the market and different tests were performed to evaluate the ability of cross-linkers in preserving the hybrid layer: mechanical test (microtensile bond strength), qualitative test (nanoleakage analysis), and biochemical assays (zymographic analysis and in situ zymographic analysis). For the microtensile bond strength recently extracted third molars (N=5 for each group) were selected and restorative treatments were performed: in the experimental groups teeth were pretreated with the tested cross-linkers before the application of the adhesive systems (XP Bond, Scotch Bond 1XT, Optibond FL, Clearfil SE), while in the control groups the adhesives were applied according to the manufacturers’ instructions. The experimental groups were divided as follow: 1) 0.1% riboflavin/XP Bond; 0.3M EDC/Scotch Bond 1XT; 2) 0.3M EDC+XP Bond 3) 0.3M EDC+Scotch Bond 1XT; 4) 0.3M EDC+Optibond FL; 5) 0.01% acrolein+Scotch Bond 1XT; 6) 0.3M EDC+Clearfil SE. The bonded specimens were serially sectioned to obtain approximately 1-mm-thick beams in accordance with the microtensile non-trimming technique. Beams were stored at 37°C in artificial saliva to reproduce the oral cavity environment and then were stressed to failure after 24hours (T0), 6 months (T6) or 1 year (T12) using a simplified universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed using Two-Way (variables: cross-linker pretreatment and storage time) analysis of variance (ANOVA) and post hoc Tukey test (p values < 0.05 were considered as statistically significant). The results of microtensile bond strength showed that the use of the tested cross-linkers tested does not affect the immediate bond strength, while at T12 bond strength values of the experimental groups are significantly higher compared to the control groups. For the qualitative interfacial nanoleakage analysis, additional molars (4 per group) were selected to evaluate the integrity of the tooth/resin interfaces. The experimental groups were divided as follow: 1) 0.1% riboflavin-XP Bond; 2) 0.3M EDC-Scotch Bond 1XT; 3) 0.3M EDC-Optibond FL. The specimens were prepared and stored as described for the microtensile test; after storage the beams were immersed for 24h in AgNO3, then rinsed in distilled water and immersed in photo-developing solution to reduce silver ions into metallic silver grain. Nanoleakage analysis was performed under light microscopy and the interfacial nanoleakage degree was scored on a scale of 0–4 based on the percentage of the adhesive surface showing silver nitrate deposition: 0: no nanoleakage; 1: <25% nanoleakage; 2: 25 to ≤50% nanoleakage; 3: 50 to ≤75% nanoleakage; and 4: >75% nanoleakage. Statistical differences among nanoleakage group scores were analyzed using the χ2 test. The results did not reveal differences in the interfacial nanoleakage expression between the experimental groups 2 (0.3M EDC-Scotch Bond 1XT) and 3 (0.3M EDC-Optibond FL) and their respective control group. After 12-month storage the treatment with the riboflavin significantly reduce the infiltration of AgNO3 within the hybrid layer created with XP Bond. For the biochemical assay of the enzymatic activity, zymographic analysis and in situ zymography were performed. The following groups were added to the previously described treatments and submitted to these tests: 0.5M DCC/ethanol, 0.5M DCC/acetone, 0.5M DCC/ethanol- Scotchbond 1XT, 0.5M DCC/acetone Scotchbond 1XT. For the zymographic analysis dentin powder was obtained from thirty human sound molars; the powder was treated with the cross-linking agents in association or not with the different adhesive systems. The extract proteins were submitted to electrophoresis on SDS-polyacrylamide gels copolymerized with gelatin as MMPs substrate. Zymograms showed that the use of cross-linkers before the adhesive application was able to reduce or totally inhibit the activity of MMPs (especially MMP-2 and MMP-9). The specimens submitted to in situ zymography were prepared as previous described for the microtensile test. Bonded specimens were cut in order to expose the adhesive/dentin interfaces and in situ zymography was performed applying a self-quenched fluorescein-conjugated gelatin on adhesive/dentin interface. The specimens were light-protected and incubated in humidified chambers at 37°C for 24 h, then the hydrolysis of quenched fluorescein-conjugated gelatin substrate (related to endogenous gelatinolytic enzyme activity) was assessed by examination with a confocal laser scanning microscope. Images revealed reduced green fluorescence in the hybrid layer of experimental groups (pretreated with the cross-linking agents) compared to the control group fluorescence. The results of all these studies suggest that the use of cross-linking agents before the bonding procedures improves the stability of the resin/dentin interface. We can speculated that cross-linkers are able to reinforced the dentin collagen network increasing the mechanical properties of the hybrid layer, as confirmed by the microtensile test. Furthermore the results showed that these agents are able to inhibit the MMP gelatinolytic activity, preserving the dentin collagen fibrils from the hydrolysis and avoiding the failure of the hybrid layer.
L’odontoiatria adesiva si basa sulla capacità delle resine adesive di penetrare all’interno del network del collagene dentinale portando alla formazione del cosiddetto strato ibrido; la stabilità e l’integrità delle fibrille collagene dello strato ibrido sono fondamentali per preservare le caratteristiche dell’adesione al tessuto dentinale nel tempo. È noto che le metallo-proteinasi della matrice (MMPs), enzimi endogeni della dentina, possono causare l’idrolisi e la conseguente degradazione dello strato ibrido dentinale. Scopo del presente progetto di ricerca è stata la valutazione dell’efficacia di diversi agenti cross-linkers del collagene sulla stabilità dell’interfaccia adesivo/dentinale. Inizialmente sono stati testati due diversi agenti cross-linkers, entrambi solubili in acqua: la riboflavina ed il carbodiimide hydrochloride, 1-Ethyl-3-[3-dimethylaminopropyl] (EDC), successivamente sono state incluse nello studio altre due sostanze: l’acroleina (solubile in acqua), e il N,N'-dicyclohexylcarbodiimide (DCC) (solubile in etanolo o acetone). La concentrazione di ogni soluzione testata è stata scelta in accordo con la letteratura: 0.1% riboflavina/wt, 0.3M EDC/wt, 0,01% acroleina/wt, 0.5M DCC/etanolo, 0.5M/acetone. Gli agenti cross-linkers sono stati testati in associazione a diversi sistemi adesivi disponibili sul mercato. Al fine di valutarne la capacità nella conservazione dello strato ibrido sono state scelte diverse tipologie di analisi: meccanica (microtensile bond strength), qualitativa (analisi del nanoleakage), e biochimiche (zimografia e zimografia in situ). L’analisi meccanica è stata effettuata mediante il test del microtensile per il quale sono stati scelti denti molari umani (5 per gruppo) su cui sono state effettuate le procedure per un restauro adesivo: nei gruppi sperimentali la dentina è stata trattata con l’agente cross-linker scelto prima dell’applicazione del sistema adesivo; nei gruppi controllo gli adesivi (XP Bond, Scotch Bond 1XT, Optibond FL, Clearfil SE) sono stati utilizzati seguendo le istruzioni del produttore. I gruppi sperimentali sono stati suddivisi nel seguente modo: 1) 0.1% riboflavina+XP Bond; 0.3M EDC+Scotch Bond 1XT; 2) 0.3M EDC+XP Bond 3) 0.3M EDC+ScotchBond 1XT; 4) 0.3M EDC+Optibond FL; 5) 0.01% acrolein+ScotchBond 1XT; 6) 0.3M EDC+Clearfil SE. I campioni sono stati poi tagliati per ottenere sticks delle dimensioni di 1 mm circa di spessore in accordo con la “non-trimming technique”. I campioni ottenuti sono stati conservati, in saliva artificiale a 37°C per simulare l’ambiente del cavo orale. Dopo 24 ore (T0), 6 mesi (T6), e 1 anno (T12) i campioni sono stati sottoposti a test di trazione usando una macchina universale alla velocità di 1 mm/min. I dati sono stati analizzati con il test di ANOVA a due vie (trattamento con il cross-linker/tempo di storaggio) e con il post hoc Tukey test (valori di p < 0.05 indicano differenza statisticamente significativa). I risultati del test di microtensile hanno mostrato che il pretrattamento con cross-linkers del collagene non influisce sui valori di adesione a T0, mentre i valori a T12 evidenziano che l’uso dei cross-linkers aumenta significativamente l’adesione rispetto ai rispettivi gruppi controllo. L’analisi qualitativa dell’interfaccia adesiva è stata effettuata mediante valutazione del nanoleakage. A tale scopo, sono stati aggiunti altri 4 molari per ciascun gruppo. I gruppi sperimentali sono stati divisi come segue: 1) 0.1% riboflavina+XP Bond; 2) 0.3M EDC+Scotch Bond 1XT; 3) 0.3M EDC+Optibond FL. I campioni sono stati preparati come precedentemente descritto per il test di microtensile e dopo i medesimi tempi di storaggio i campioni sono stati immersi in una soluzione acquosa di nitrato di argento (AgNO3) per 24 ore, sciacquati, e successivamente immersi in liquido di sviluppo al fine di ridurre gli ioni di argento. I campioni sono stati quindi analizzati al microscopio ottico, ed il nanoleakage è stato quantificato con valori da 0 a 4, basandosi sulla percentuale di superficie dello strato ibrido infiltrata dal nitrato d’argento, come segue: 1: <25% nanoleakage; 2: 25 a ≤50% nanoleakage; 3: 50 a ≤75% nanoleakage; and 4: >75% nanoleakage. I dati sono stati analizzati utilizzando il χ2 test. I risultati mostrano differenze significative a T12 solo per il gruppo 1 (0.1% riboflavina-XP Bond), in cui il gruppo sperimentale trattato con agente cross-linkers presenta all’interno dello strato ibrido una minore quantità di AgNO3 se comparato al gruppo controllo. Al contrario gli altri due cross-linkers presi in analisi non hanno mostrato differenze statisticamente significative in relazione al loro uso a T0 o T12. In relazione ai tests biochimici, sono state effettuati test si zimografia e la zimografia in situ al fine di valutare l’attività enzimatica delle MMPs dentinali in relazione al trattamento con agenti cross-linkers. Ai gruppi precedentemente testati sono stati aggiunti ulteriori 4 gruppi sperimentali: 0.5M DCC/etanolo, 0.5M DCC/acetone, 0.5M DCC/etanolo-Scotchbond 1XT, 0.5M DCC/acetone-Scotchbond 1XT. Per la zimografia sono stati scelti trenta molari sani dai quali è stata isolata la dentina e polverizzata. La polvere di dentina è poi stata trattata con i diversi cross-linkers e adesivi come precedentemente descritto. Le proteine estratte dalla polvere dentinale, trattata secondo i diversi gruppi di appartenenza, sono state quindi sottoposte a corsa elettroforetica su gel di SDS-page co-polimerizzato con gelatina, come substrato delle MMPs. I gels ottenuti mostrano che il trattamento della dentina con agenti cross-linker prima dell’applicazione degli adesivi dentinali è in grado di diminuire o inibire quasi completamente l’attività gelatinolitica delle MMPs (MMP-2 -9 in particolare). Per quanto riguarda la zimografia in situ i campioni sono stati preparati come descritto per il test di microtensile, successivamente sono stati tagliati in modo da esporre l’interfaccia adesiva. A livello della stessa interfaccia è stata posta della gelatina coniugata con fluorescina. L’idrolisi della gelatina causata dagli enzimi endogeni dentinali determina l’attivazione della fluorescenza evidenziando quindi in situ l’attività enzimatica. I campioni sono stati osservati mediante microscopio confocale ed hanno evidenziato una minore fluorescenza all’interno dello strato ibrido di tutti gruppi sperimentali presi in analisi se confrontate con i rispettivi gruppi controllo. In conclusione possiamo affermare che l’uso degli agenti cross-linkers del collagene prima delle procedure adesive migliora le caratteristiche generali dello strato ibrido. È possibile suppore che i cross-linkers siano in grado di rinforzare il network del collagene dentinale aumentandone le proprietà meccaniche, come dimostrato dal test del microtensile; inoltre i tests enzimatici mostrano come questi agenti siano in grado di inibire l’attività enzimatica delle MMPs preservando in questo modo l’idrolisi delle fibrille collagene ed evitando la conseguente disgregazione dello strato ibrido.
XXVII Ciclo
1986
APA, Harvard, Vancouver, ISO, and other styles
5

Sutil, Bruna Gabrielle da Silva. "EFEITOS DO PRÉ-TRATAMENTO DENTINÁRIO E TEMPERATURA DO ADESIVO NA RESISTÊNCIA ADESIVA DE UM SISTEMA ADESIVO UNIVERSAL." Universidade Federal de Santa Maria, 2016. http://repositorio.ufsm.br/handle/1/6190.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
This study aimed to evaluate the effects of dentin pretreatment and temperature on the bond strength of a universal adhesive system to dentin. Ninety-six extracted non-carious human third molars were randomly divided into 12 groups (n=8) according to Scotchbond Universal Adhesive (SbU) applied in self-etch (SE) and total-etch (TE) mode, adhesive temperature (20ºC or 37ºC) and sodium bicarbonate or aluminum oxide air abrasion. After composite build up, bonded sticks with cross-sectional area of 1 mm² were obtained to evaluate the microtensile bond strength (μTBS). The specimens were tested at a crosshead speed of 0.5 mm/min on a universal testing machine until failure. Fractured specimens were analyzed under stereomicroscope to determine the failure patterns in adhesive, cohesive (dentin or resin) and mixed fractures. The microtensile bond strength data was analyzed using to two-way ANOVA and Tukey s test (p<0.01). Interaction between treatment and temperature was statistically significant to SbU applied in SE technique. Both dentin treatments showed higher bond strength to TE mode, regardless of adhesive temperature. When compared to control group, sodium bicarbonate increased bond strength of SbU in SE mode. Adhesive temperature did not significantly affect the μTBS of tested groups. Predominantly, adhesive failure was observed for all groups. Thus, the dentin pretreatment may be an alternative to improve the adhesive properties of the Scotchbond Universal adhesive system.
O presente estudo avaliou os efeitos do jateamento de partículas abrasivas e da temperatura sobre a resistência adesiva de um sistema adesivo universal à dentina. Utilizou-se 96 terceiros molares humanos hígidos e extraídos, divididos aleatoriamente em 12 grupos (n=8) de acordo com o adesivo Scotchbond Universal (SBU) aplicado no modo autocondicionante (SE) ou condicionamento ácido total (TE), temperatura do adesivo (20ºC ou 37ºC) e jateamento da dentina com partículas de óxido de alumínio ou bicarbonato de sódio. Após a realização das restaurações, foram obtidos espécimes em forma de palito com área seccional de 1 mm² para avaliar a resistência adesiva através do teste de microtração. O teste foi realizado em uma máquina de ensaio universal, a uma velocidade de 0,5 mm/min até a fratura ocorrer. As fraturas foram analisadas sob estereomicroscopia para classificar as falhas em adesiva, coesiva (resina ou dentina) e mista. Os dados foram submetidos ao teste ANOVA a dois fatores e ao teste de Tukey. A interação entre tratamento e temperatura foi estatisticamente significante (p<0,01) para SBU SE. Ambos os tratamentos da dentina resultaram em valores maiores de resistência adesiva para SBU no modo TE, independente da temperatura do adesivo. Já para SBU aplicado na técnica autocondicionante, apenas o jateamento com bicarbonato de sódio foi significativamente diferente quando comparado ao grupo que não recebeu tratamento. O adesivo aquecido não teve influência significativa sobre a resistência adesiva à microtração, para todos os grupos testados. As fraturas adesivas foram predominantes para todos os grupos. Dessa forma, o pré-tratamento dentinário pode ser uma alternativa para melhorar as propriedades adesivas do sistema adesivo Scotchbond Universal.
APA, Harvard, Vancouver, ISO, and other styles
6

Melo, Renata Marques de [UNESP]. "Efeitos do tipo de sistema adesivo e região do dente sobre a resistência adesiva à dentina." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/113977.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-06-13Bitstream added on 2015-01-26T13:30:28Z : No. of bitstreams: 1 000326687.pdf: 2821504 bytes, checksum: 1d66d1ded90d9d6ea873a9687a44bde1 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Este estudo foi realizado no intuito de avaliar a resistência de união à dentina coronária e do canal radicular com dois sistemas adesivos de condicionamento total (dois e três passos) e um sistema autocondicionante. Os canais de trinta incisivos e caninos humanos superiores foram instrumentados e preparados com brocas. Os pinos usados na cimentação foram réplicas em cimento resinoso dual Duo-link do pino Aestheti Plus #2. Assim, constituíram-se três grupos (n = 10), segundo o sistema adesivo utilizado: condicionamento total três passos (CT3) - AII-Bond 2 + pino em cimento resinoso (pcr)+ Duo-link (DI); condicionamento total 2 passos (CT2) - One-Step Plus + pcr + DI; autocondicionante (AC) - Tyrian/One-Step Plus+ pcr + DI. Apôs a cimentação, foram obtidas oito secções transversais (1,5mm), a partir de 4mm acima da JEC até 4mm aquém do ápice do canal, envolvendo dentina coronária e radicular. As secções foram submetidas ao ensaio de push-out em máquina de ensaio universal EMIC (1 mm.min-1). Os dados de resistêncía adesiva foram analisados com o teste ANOVA de dois fatores de medidas repetidas (α<0,05). Foi observado que o efeito interação foi estatisticamente significante, isto é, o relacionamento entre os adesivos não foi o mesmo para as diferentes regiões. Comparando-se as médias obtidas com os adesivos em cada região (Tukey; α<0,05), observou-se que o CT3 (média± desvio padrão: 5,22 ± 1,70) foi superior ao CT2 (2,60 ± 1,74) e ao AC (1,68 ± 1,85). Para as condições estudadas, obteve-se melhor adesão à dentina com a utilização do sistema adesivo de condicionamento total com três passos, sobretudo na região coronária
This study aimed to evaluate lhe bond strengths between two total etching adhesive systems and (two and three steps) anda self-etching system to coronal and root canal dentin. The root canal of thirty human anterior teeth were endodontically instrumented and prepared with specific burs. Aestheti Plus #2 posts were duplicated in dual resin cement (Duo-link) and three groups (n=10) were formed, according to the adhesive sysfem used: 3 steps total etching adhesive system (3TE) - All-Bond 2 + resin cement post (rcp) + Duo-link (DI); 2 steps total etching adhesive system (2TE) - One-Step Plus + rcp + DI; sef-etching system (SE) Tyrian/One-Step Plus + rcp +DI. Following cementation, the teeth were cut transversally in eight sections (1,5mm), from the CEJ to 4mm above the canal apex. The sections were subjected to the push-out test in a universal testing machine (1mm.min-1). The data of bond strength were statistically analyzed with 2-way Anova of repeated measures (α<0.05), which showed that the interaction effect was significant. This meant that the relationship between the adhesives was not the same depending on the tooth region. Regarding the adhesive factor'' the comparison of means with Tukey test (α<0.05) showed that 3TE (mean ± standard deviation: 5,22 ± 1,70) was statistically superior to 2TE (2,60 ± 1,74) and SE (1,68 ± 1,85). Under the conditions of the present study, the three step total etching system had the highest bond strengths to dentin, especially in the coronal region
APA, Harvard, Vancouver, ISO, and other styles
7

Melo, Renata Marques de. "Efeitos do tipo de sistema adesivo e região do dente sobre a resistência adesiva à dentina /." São José dos Campos, 2005. http://hdl.handle.net/11449/113977.

Full text
Abstract:
Orientador: Carlos Augusto Pavanelli
Banca: Paulo Sérgio Mutarelli
Banca: Carlos Rocha Gomes Torres
Resumo: Este estudo foi realizado no intuito de avaliar a resistência de união à dentina coronária e do canal radicular com dois sistemas adesivos de condicionamento total (dois e três passos) e um sistema autocondicionante. Os canais de trinta incisivos e caninos humanos superiores foram instrumentados e preparados com brocas. Os pinos usados na cimentação foram réplicas em cimento resinoso dual Duo-link do pino Aestheti Plus #2. Assim, constituíram-se três grupos (n = 10), segundo o sistema adesivo utilizado: condicionamento total três passos (CT3) - AII-Bond 2 + pino em cimento resinoso (pcr)+ Duo-link (DI); condicionamento total 2 passos (CT2) - One-Step Plus + pcr + DI; autocondicionante (AC) - Tyrian/One-Step Plus+ pcr + DI. Apôs a cimentação, foram obtidas oito secções transversais (1,5mm), a partir de 4mm acima da JEC até 4mm aquém do ápice do canal, envolvendo dentina coronária e radicular. As secções foram submetidas ao ensaio de push-out em máquina de ensaio universal EMIC (1 mm.min-1). Os dados de resistêncía adesiva foram analisados com o teste ANOVA de dois fatores de medidas repetidas (α<0,05). Foi observado que o efeito interação foi estatisticamente significante, isto é, o relacionamento entre os adesivos não foi o mesmo para as diferentes regiões. Comparando-se as médias obtidas com os adesivos em cada região (Tukey; α<0,05), observou-se que o CT3 (média± desvio padrão: 5,22 ± 1,70) foi superior ao CT2 (2,60 ± 1,74) e ao AC (1,68 ± 1,85). Para as condições estudadas, obteve-se melhor adesão à dentina com a utilização do sistema adesivo de condicionamento total com três passos, sobretudo na região coronária
Abstract: This study aimed to evaluate lhe bond strengths between two total etching adhesive systems and (two and three steps) anda self-etching system to coronal and root canal dentin. The root canal of thirty human anterior teeth were endodontically instrumented and prepared with specific burs. Aestheti Plus #2 posts were duplicated in dual resin cement (Duo-link) and three groups (n=10) were formed, according to the adhesive sysfem used: 3 steps total etching adhesive system (3TE) - All-Bond 2 + resin cement post (rcp) + Duo-link (DI); 2 steps total etching adhesive system (2TE) - One-Step Plus + rcp + DI; sef-etching system (SE) Tyrian/One-Step Plus + rcp +DI. Following cementation, the teeth were cut transversally in eight sections (1,5mm), from the CEJ to 4mm above the canal apex. The sections were subjected to the push-out test in a universal testing machine (1mm.min-1). The data of bond strength were statistically analyzed with 2-way Anova of repeated measures (α<0.05), which showed that the interaction effect was significant. This meant that the relationship between the adhesives was not the same depending on the tooth region. Regarding the "adhesive factor'' the comparison of means with Tukey test (α<0.05) showed that 3TE (mean ± standard deviation: 5,22 ± 1,70) was statistically superior to 2TE (2,60 ± 1,74) and SE (1,68 ± 1,85). Under the conditions of the present study, the three step total etching system had the highest bond strengths to dentin, especially in the coronal region
Mestre
APA, Harvard, Vancouver, ISO, and other styles
8

Silva, João Maurício Ferraz da [UNESP]. "Resistência adesiva e citotoxicidade In vitro de diferentes gerações de adesivos dentinários." Universidade Estadual Paulista (UNESP), 2010. http://hdl.handle.net/11449/101339.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-23Bitstream added on 2014-06-13T20:01:53Z : No. of bitstreams: 1 silva_jmf_dr_sjc.pdf: 673718 bytes, checksum: a9a6928557da03c914d3af794e3bd430 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O objetivo do estudo foi avaliar quatro diferentes sistemas adesivos (Multi- Purpose, Single Bond, SE Plus e Easy Bond – 3M ESPE) no que se refere à resistência adesiva ao microcisalhamento na dentina bovina. Além de avaliar a citotoxicidade desses novos sistemas adesivos por meio do teste de barrerira dentinária e ensaio de MTT em fibroblastos pulpares bovinos. Para o teste de microcisalhamento 80 dentes bovinos tiveram suas raízes seccionadas, foram embutidos em resina acrílica e tiveram a superfície vestibular desgastada expondo-se a dentina, sendo que em 40 dentes a espessura de dentina remanescente foi de 500μm e nos outros 40 de 200μm. Os cdp receberam então o procedimento adesivo de acordo com as instruções do fabricante e com auxílio de uma matriz metálica, cilindros de resina (Z 250 – 3M ESPE) de 0,8 mm de diâmetro e 1mm de altura foram construídos. Após 24h os cdp foram então submetidos ao ensaio de microcisalhamento. Para avaliar a citotoxicidade foi usado o teste de barreira dentinária. Células pulpares bovinas transformadas foram cultivadas em redes de nylon por 2 semanas, obtendo-se uma cultura de 3 dimensões. Essas culturas celulares foram separadas dos materiais testados por fatias de dentina de 500 e 200μm em um dispositivo de perfusão celular. Os materiais foram aplicados na porção cavitária do dispositivo de acordo com as instruções do fabricante, e um material de moldagem a base de silicona (President, Coltene) foi usado como controle negativo (100% de viabilidade celular). Após 24 h de periodo de exposição, a viabilidade celular foi mensurada fotometricamente (teste MTT). Por meio de estatística descritiva verificou-se que a melhor eficiência adesiva foi apresentada pelo adesivo auto-condicionante de um passo só, Easy Bond (21,06 MPa - 200μm; 27,01 MPa- 500μm) seguido pelo Single Bond (15,64 MPa - 200μm; 23,45 MPa- 500μm), SE Plus...
The aim of this study was to evaluate four different adhesive systems (Multi- Purpose, Single Bond, SE Bond Plus and Easy - 3M ESPE) with regard to microshear bond strength to bovine dentin. In addition evaluate the cytotoxicity of these new adhesive systems by means of a dentin barrier test. To test microshear 80 bovine teeth had their roots sectioned and were embedded in acrylic resin. The buccal surface had been worn to expose the dentin, in 40 teeth the remaining dentin thickness was 500μm and 200μm in the other 40. The specimes received the adhesive procedure according to the manufacturer's instructions and with the aid of a metal matrix, cylinders of resin (Z 250 - 3M ESPE) from 0.8 mm in diameter and 1mm in height were built. After 24h the specimes were then subjected to the microshear testing To evaluate the cytotoxicity, a dentin barrier test was used. SV3NeoB transfected bovine pulp derived cells were grown on nylon meshes for 2 weeks achieving a 3-dimensional cell culture as described. These cell cultures were separated from the test materials by dentin slices of 200 or 500μm thickness in a cell cultures perfusion chamber. The materials were applied into the cavity part of the device according to manufacturer’s instruction, and a silicon impression material (President, Coltene) served as a negative control material (100% cell viability). After a 24h exposure period, cell viability was measured photometrically (MTT test). Median values (plus 25% and 75% percentiles) of cell viability measurements (n=10) were statistically analyzed (Mann-Whitney test, = 0.05). Descriptive statistics found that the best bonding performance was presented by the single step adhesive Easy Bond (21.06 - 200μm, 27.01 - 500μm) followed by Single Bond (15.64 - 200μm; 23.45 - 500μm), SE Plus (18.23 - 200μm; 20.07 - 500μm) and Multi Purpose (15.24 - 200μm; 17.99 - 500μm). Moreover, it was... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
9

Silva, João Maurício Ferraz da. "Resistência adesiva e citotoxicidade "In vitro" de diferentes gerações de adesivos dentinários /." São Jose dos Campos : [s.n.], 2010. http://hdl.handle.net/11449/101339.

Full text
Abstract:
Orientador: José Roberto Rodrigues
Banca: Eduardo Shigueyuki Uemura
Banca: Carlos Henrique Ribeiro Camargo
Banca: George Miguel Spyrides
Banca: Gorgulho Zanet
Resumo: O objetivo do estudo foi avaliar quatro diferentes sistemas adesivos (Multi- Purpose, Single Bond, SE Plus e Easy Bond - 3M ESPE) no que se refere à resistência adesiva ao microcisalhamento na dentina bovina. Além de avaliar a citotoxicidade desses novos sistemas adesivos por meio do teste de barrerira dentinária e ensaio de MTT em fibroblastos pulpares bovinos. Para o teste de microcisalhamento 80 dentes bovinos tiveram suas raízes seccionadas, foram embutidos em resina acrílica e tiveram a superfície vestibular desgastada expondo-se a dentina, sendo que em 40 dentes a espessura de dentina remanescente foi de 500μm e nos outros 40 de 200μm. Os cdp receberam então o procedimento adesivo de acordo com as instruções do fabricante e com auxílio de uma matriz metálica, cilindros de resina (Z 250 - 3M ESPE) de 0,8 mm de diâmetro e 1mm de altura foram construídos. Após 24h os cdp foram então submetidos ao ensaio de microcisalhamento. Para avaliar a citotoxicidade foi usado o teste de barreira dentinária. Células pulpares bovinas transformadas foram cultivadas em redes de nylon por 2 semanas, obtendo-se uma cultura de 3 dimensões. Essas culturas celulares foram separadas dos materiais testados por fatias de dentina de 500 e 200μm em um dispositivo de perfusão celular. Os materiais foram aplicados na porção cavitária do dispositivo de acordo com as instruções do fabricante, e um material de moldagem a base de silicona (President, Coltene) foi usado como controle negativo (100% de viabilidade celular). Após 24 h de periodo de exposição, a viabilidade celular foi mensurada fotometricamente (teste MTT). Por meio de estatística descritiva verificou-se que a melhor eficiência adesiva foi apresentada pelo adesivo auto-condicionante de um passo só, Easy Bond (21,06 MPa - 200μm; 27,01 MPa- 500μm) seguido pelo Single Bond (15,64 MPa - 200μm; 23,45 MPa- 500μm), SE Plus... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The aim of this study was to evaluate four different adhesive systems (Multi- Purpose, Single Bond, SE Bond Plus and Easy - 3M ESPE) with regard to microshear bond strength to bovine dentin. In addition evaluate the cytotoxicity of these new adhesive systems by means of a dentin barrier test. To test microshear 80 bovine teeth had their roots sectioned and were embedded in acrylic resin. The buccal surface had been worn to expose the dentin, in 40 teeth the remaining dentin thickness was 500μm and 200μm in the other 40. The specimes received the adhesive procedure according to the manufacturer's instructions and with the aid of a metal matrix, cylinders of resin (Z 250 - 3M ESPE) from 0.8 mm in diameter and 1mm in height were built. After 24h the specimes were then subjected to the microshear testing To evaluate the cytotoxicity, a dentin barrier test was used. SV3NeoB transfected bovine pulp derived cells were grown on nylon meshes for 2 weeks achieving a 3-dimensional cell culture as described. These cell cultures were separated from the test materials by dentin slices of 200 or 500μm thickness in a cell cultures perfusion chamber. The materials were applied into the cavity part of the device according to manufacturer's instruction, and a silicon impression material (President, Coltene) served as a negative control material (100% cell viability). After a 24h exposure period, cell viability was measured photometrically (MTT test). Median values (plus 25% and 75% percentiles) of cell viability measurements (n=10) were statistically analyzed (Mann-Whitney test, = 0.05). Descriptive statistics found that the best bonding performance was presented by the single step adhesive Easy Bond (21.06 - 200μm, 27.01 - 500μm) followed by Single Bond (15.64 - 200μm; 23.45 - 500μm), SE Plus (18.23 - 200μm; 20.07 - 500μm) and Multi Purpose (15.24 - 200μm; 17.99 - 500μm). Moreover, it was... (Complete abstract click electronic access below)
Doutor
APA, Harvard, Vancouver, ISO, and other styles
10

Barros, Lívia de Oliveira. "Estabilidade da interface de união de sistemas adesivos convencionais aplicados à dentina saturada com alcoóis." reponame:Repositório Institucional da UFC, 2011. http://www.repositorio.ufc.br/handle/riufc/13655.

Full text
Abstract:
BARROS, Lívia de Oliveira. Estabilidade da interface de união de sistemas adesivos convencionais aplicados à dentina saturada com alcoóis. 2011. 50 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2011.
Submitted by denise santos (denise.santos@ufc.br) on 2015-10-21T15:16:50Z No. of bitstreams: 1 2011_dis_lobarros.pdf: 840593 bytes, checksum: bb384edc1f750fa69323f9aa3daf978b (MD5)
Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2015-10-21T15:25:42Z (GMT) No. of bitstreams: 1 2011_dis_lobarros.pdf: 840593 bytes, checksum: bb384edc1f750fa69323f9aa3daf978b (MD5)
Made available in DSpace on 2015-10-21T15:25:42Z (GMT). No. of bitstreams: 1 2011_dis_lobarros.pdf: 840593 bytes, checksum: bb384edc1f750fa69323f9aa3daf978b (MD5) Previous issue date: 2011
There is a consensus that the resin-dentin bond instability is correlated with increased hydrophilic resin monomer content in dentin adhesive. Thus, more durable bonds could be created when more hydrophobic resins were used. One way to bond hydrophobic monomers to acid-etched dentin is saturating the demineralized dentin with ethanol instead of water (ethanol-wet bonding technique). The objective of this in vitro study was to evaluate the effect of “alcohol wet bonding” technique on the stability of adhesive interface produced by two-step etch-and-rinse adhesives systems. For this, it was used 20 human third molars that had superficial dentin exposed and were randomly divided into four experimental groups (n=5): Adper Single Bond 2 (SB) bonded to acid-etched dentin saturated with water or ethanol; and XP Bond (XP) bonded acid-etched dentin saturated with water or 99.5% tert-butanol. The simplified dentin dehydration protocol was performed using 2 μl 100% ethanol or 99.5% tert-butanol directly applied in dentin for 60 s. Composite build-ups were built on dentin surface and specimens were cut into non-trimming dentin-composite beams to microtensile testing. Beams from each tooth were divided equally in two subgroups: immediately tested and aged by immersion in 10% NaOCl solution for 1 h. Specimens were pulled until failure at crosshead speed of 1 mm/min and bond strength was calculated. Fractured sticks were analyzed and classified according to the failure mode as mixed, adhesive, cohesive in dentin and cohesive in composite; and expressed in percentage. Data from μTBS test were statistically analyzed using three-way ANOVA and Tukey tests (α=0.05). Additional dentin disks were bonded using the same groups tested and the morphological characteristics of adhesive interface were investigated by light microscopy after immersion in ammoniacal silver nitrate solution. μTBS results showed that NaOCl solution reduced significantly bond strength comparing with the control groups (p<0.05) and increased the silver nitrate interfacial deposit for all adhesives tested. SB used in ethanol saturated-dentin showed significant lower bond strength values in comparison with SB control group, and this same tendency was observed in the silver nitrate deposition. The use of tert-butanol did not influence XP bond strengths values and silver nitrate deposits. Conclusion: The “alcohol wet bonding” simplified technique used in the present study was not able to improve resin-dentin bond stability for simplified etch-and-rinse adhesive systems.
Existe um consenso de que a instabilidade da interface de união resina-dentina está relacionada com a quantidade de monômeros hidrofílicos presentes no sistema adesivo. Dessa forma, interfaces adesivas mais duradouras seriam alcançadas com a utilização de sistemas adesivos mais hidrofóbicos. Uma maneira de unir monômeros hidrófobos à dentina é através da saturação da matriz dentinária desmineralizada por etanol ao invés de água (ethanol-wet bonding technique). O objetivo deste trabalho in vitro foi avaliar o efeito do protocolo de saturação dentinária, utilizando alcoóis, na estabilidade da interface de união produzida por sistemas adesivos convencionais de dois passos. Para isso, foram utilizados 20 terceiros molares humanos, que tiveram a dentina coronária exposta e foram distribuídos aleatoriamente em quatro grupos experimentais (n=5): Adper Single Bond 2 (SB) aplicado sobre dentina saturada com água ou etanol; e XP Bond (XP) aplicado sobre dentina saturada com água ou tert-butanol. O protocolo de saturação da dentina foi realizado através da aplicação de 2 μl de etanol 100% ou tert-butanol 99,5% diretamente sobre a dentina por um período de 60 s. Um platô de resina composta foi confeccionado sobre superfície dentinária após a aplicação do sistema adesivo e os espécimes foram cortados pela técnica non-trimming de obtenção de palitos para o teste de microtração. Os palitos de cada dente foram igualmente divididos em dois subgrupos: imediatamente testado ou envelhecido em solução de NaOCl a 10% por 1 hora. Os espécimes foram tracionados até a ruptura da união a uma velocidade de 1 mm/min e sua força de união mensurada. Os palitos fraturados foram analisados e classificados de acordo com o modo de fratura em mista, adesiva, coesiva em dentina e coesiva em compósito, e os valores expressos em porcentagem. Os valores de resistência de união foram estatisticamente analisados usando os testes ANOVA a três critérios e Tukey (α=0.05). Discos extras de dentina foram submetidos aos procedimentos adesivos de cada grupo testado e utilizados para investigar as características morfológicas da interface de união através de microscopia óptica após imersão em solução amonical de nitrato de prata. Os resultados do teste de microtração mostraram que a imersão em solução de NaOCl reduziu significativamente a força de união em comparação aos grupos controle (p<0.05) e aumentou a nanoinfiltração das interfaces adesivas de todos os sistemas adesivos testados. A saturação da dentina com etanol 100% reduziu os valores de resistência adesiva para SB quando comparado ao grupo controle, e esta mesma tendência foi observada na infiltração de prata. O uso do tert-butanol 99,5% não afetou os valores de resistência adesiva para o XP, assim como a deposição de nitrato de prata na interface adesiva. Conclusão: Os protocolos simplificados de saturação da dentina com alcoóis utilizados no presente estudo não foram capazes de melhorar a estabilidade da interface de união para sistemas adesivos convencionais de dois passos.
APA, Harvard, Vancouver, ISO, and other styles
11

Farias, Caroline Leão Cordeiro de [UNESP]. "Avaliação da resistência adesiva à microtração após desproteinização da dentina. Efeito de diferentes sistemas adesivos." Universidade Estadual Paulista (UNESP), 2004. http://hdl.handle.net/11449/89678.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-07Bitstream added on 2014-06-13T18:51:45Z : No. of bitstreams: 1 farias_clc_me_arafo.pdf: 808344 bytes, checksum: 95ebf651344a3331fa67cd1e8c616f15 (MD5)
O objetivo deste trabalho foi avaliar, in vitro, os efeitos da desproteinização da dentina sobre a resistência de união de três diferentes sistemas adesivos. Para tal, 30 terceiros molares humanos hígidos foram seccionados transversalmente, por meio de disco diamantado, na união do terço médio com o terço oclusal e desgastados com discos de lixa de granulação 320 e 600 para completa exposição da superfície dentinária e padronização da smear layer. Em seguida, os dentes foram divididos aleatoriamente em 6 grupos (n=5), os quais receberam aplicação dos sistemas adesivos Prime & Bond 2.1 (Dentsply), Single Bond (3M) e Clearfil SE Bond (Kuraray) de acordo com as instruções dos fabricantes (Grupos 2, 4 e 6, respectivamente) ou após desproteinização da dentina com hipoclorito de sódio a 5% durante 2 minutos (Grupos 1, 3 e 5, respectivamente). Restaurações de resina composta Z100 foram confeccionadas, de forma incremental, sobre toda a superfície oclusal. Os dentes foram, então, seccionados com disco diamantado com a finalidade de obter amostras em forma de palitos de 1,0 l 0,2mm2 de área adesiva. Vinte e cinco amostras de cada grupo foram selecionadas e armazenadas por 24 horas em água destilada a temperatura de 37ºC. Em seguida, os testes de microtração foram realizados em Máquina Universal de Ensaios MTS, à velocidade do atuador de 0,5mm/min. Os resultados, analisados estatisticamente por meio de Análise de variância e Teste de Tukey (p<0,05), indicaram que a aplicação do NaOCl proporcionou redução da resistência adesiva para todos os grupos (G1- 29,16 l 3,98; G3- 23,06 l 4,87; G5- 26,71 l 5,10) quando comparados com os grupos controle (G2- 33,11 l 5,76; G4- 30,62 l 5,47; G6- 32,09 l 6,43). Em relação aos padrões de fratura, observou-se predominância de fraturas adesivas, sendo que estas, nos grupos onde a dentina foi... .
The aim of this study was to evaluate, in vitro, the influence of dentin deproteinization on microtensile bond strength of three different adhesive systems. Thirty freshly extracted human molars were transversely wetcut using a diamond disk in order to expose the oclusal dentin surface. The teeth were randomly divided into 6 groups (n=5) and the adhesive systems Prime & Bond 2.1 (Dentsply), Single Bond (3M) e Clearfil SE Bond (Kuraray) were applied according to the manufacturer's instruction (control groups: G2, G4 and G6) or after application of sodium hypochlorite 5% for 2 minutes (G1, G3 and G5). The teeth were restored with Z100 (3M) composite resin and the microtensile specimens, with a bonded area of 1,00l 0,2mm2, were prepared by a slow-speed diamond disk. Twenty-five specimens of each group were selected and stored in distilled-water at 37oC for 24 hours. The microtensile tests were performed in a MTS universal testing machine with a cross-head speed of 0,5mm/min. The results were statistically analyzed by ANOVA and Tukey's test (p=0,05). Sodium hypochlorite pre-treatment significantly decreased the microtensile bond strength values of all adhesive systems (G1- 29,16 l 3,98; G3- 23,06 l 4,87; G5- 26,71 l 5,10) compared to control groups (G2- 33,11 l 5,76; G4- 30,62 l 5,47; G6- 32,09 l 6,43). Analysis of the morphology of the failure pattern revealed that, for the control specimens, debonding had occurred in the composite/teeth interface and in specimens that were etched and deproteinized, debonding was characterized by resin failure through the wide bases of the tag extensions into dentinal tubules.
APA, Harvard, Vancouver, ISO, and other styles
12

Farias, Caroline Leão Cordeiro de. "Avaliação da resistência adesiva à microtração após desproteinização da dentina. Efeito de diferentes sistemas adesivos /." Araraquara : [s.n.], 2004. http://hdl.handle.net/11449/89678.

Full text
Abstract:
Orientador: Welingtom Dinelli
Banca: José Roberto Cury Saad
Banca: Silmara Aparecida Milori Corona
Resumo: O objetivo deste trabalho foi avaliar, in vitro, os efeitos da desproteinização da dentina sobre a resistência de união de três diferentes sistemas adesivos. Para tal, 30 terceiros molares humanos hígidos foram seccionados transversalmente, por meio de disco diamantado, na união do terço médio com o terço oclusal e desgastados com discos de lixa de granulação 320 e 600 para completa exposição da superfície dentinária e padronização da "smear layer". Em seguida, os dentes foram divididos aleatoriamente em 6 grupos (n=5), os quais receberam aplicação dos sistemas adesivos Prime & Bond 2.1 (Dentsply), Single Bond (3M) e Clearfil SE Bond (Kuraray) de acordo com as instruções dos fabricantes (Grupos 2, 4 e 6, respectivamente) ou após desproteinização da dentina com hipoclorito de sódio a 5% durante 2 minutos (Grupos 1, 3 e 5, respectivamente). Restaurações de resina composta Z100 foram confeccionadas, de forma incremental, sobre toda a superfície oclusal. Os dentes foram, então, seccionados com disco diamantado com a finalidade de obter amostras em forma de palitos de 1,0 l 0,2mm2 de área adesiva. Vinte e cinco amostras de cada grupo foram selecionadas e armazenadas por 24 horas em água destilada a temperatura de 37ºC. Em seguida, os testes de microtração foram realizados em Máquina Universal de Ensaios MTS, à velocidade do atuador de 0,5mm/min. Os resultados, analisados estatisticamente por meio de Análise de variância e Teste de Tukey (p<0,05), indicaram que a aplicação do NaOCl proporcionou redução da resistência adesiva para todos os grupos (G1- 29,16 l 3,98; G3- 23,06 l 4,87; G5- 26,71 l 5,10) quando comparados com os grupos controle (G2- 33,11 l 5,76; G4- 30,62 l 5,47; G6- 32,09 l 6,43). Em relação aos padrões de fratura, observou-se predominância de fraturas adesivas, sendo que estas, nos grupos onde a dentina foi... (Resumo completo, clicar acesso eletrônico abaixo).
Abstract: The aim of this study was to evaluate, in vitro, the influence of dentin deproteinization on microtensile bond strength of three different adhesive systems. Thirty freshly extracted human molars were transversely wetcut using a diamond disk in order to expose the oclusal dentin surface. The teeth were randomly divided into 6 groups (n=5) and the adhesive systems Prime & Bond 2.1 (Dentsply), Single Bond (3M) e Clearfil SE Bond (Kuraray) were applied according to the manufacturer's instruction (control groups: G2, G4 and G6) or after application of sodium hypochlorite 5% for 2 minutes (G1, G3 and G5). The teeth were restored with Z100 (3M) composite resin and the microtensile specimens, with a bonded area of 1,00l 0,2mm2, were prepared by a slow-speed diamond disk. Twenty-five specimens of each group were selected and stored in distilled-water at 37oC for 24 hours. The microtensile tests were performed in a MTS universal testing machine with a cross-head speed of 0,5mm/min. The results were statistically analyzed by ANOVA and Tukey's test (p=0,05). Sodium hypochlorite pre-treatment significantly decreased the microtensile bond strength values of all adhesive systems (G1- 29,16 l 3,98; G3- 23,06 l 4,87; G5- 26,71 l 5,10) compared to control groups (G2- 33,11 l 5,76; G4- 30,62 l 5,47; G6- 32,09 l 6,43). Analysis of the morphology of the failure pattern revealed that, for the control specimens, debonding had occurred in the composite/teeth interface and in specimens that were etched and deproteinized, debonding was characterized by resin failure through the wide bases of the tag extensions into dentinal tubules.
Mestre
APA, Harvard, Vancouver, ISO, and other styles
13

Siqueira, Fabiana Suelen Figueredo de. "ALTERNATIVAS PARA MELHORAR AS PROPRIEDADES ADESIVAS DE SISTEMAS ADESIVOS UNIVERSAIS EM DENTINA EROSIONADA." UNIVERSIDADE ESTADUAL DE PONTA GROSSA, 2017. http://tede2.uepg.br/jspui/handle/prefix/1729.

Full text
Abstract:
Made available in DSpace on 2017-07-24T19:22:05Z (GMT). No. of bitstreams: 1 FABIANA SIQUEIRA.pdf: 4384235 bytes, checksum: 655ceab1a73a43f410cdb4b5e3773475 (MD5) Previous issue date: 2017-04-07
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
The aim of the present study was evaluate the adhesive properties of eroded dentin with different pH cycling using universal adhesive systems and to evaluate the application of collagen cross-linking agent or MMP inhibitors on the resin-eroded dentin interface, through of three in vitro studies. For the experiment 1, the teeth were randomly assigned into the experimental groups according to the combination of variables: dentin surface (sound dentin and eroded dentin) vs adhesive systems (10 universal adhesives) vs Adhesive strategy [etch-and-rinse (ER) and self-etch (SE)]. The adhesive systems were applied according to the manufacturer's instructions and the teeth were restored. They were sectioned to analysis of microtensile bond strength (μTBS) and nanoleakage (NL). The surfaces of 2 tooth were examined under scanning electron microscopy (SEM) to evaluate the surface characterization after erosive-cycling. For experiment 2, the teeth were randomly assigned into 18 experimental conditions according to the variables: Erosive cycling (eroded dentin with soft drink pH ≈ 2,7 and eroded dentin with citric acid pH 2.3) vs. adhesive systems [Prime & Bond Elect (PBE); Scotchbond Universal Adhesive (SBU); Tetric N-Bond Universal (TEU)] vs Treatment agents [6.5% primer containing proanthocyanidin (PA) and 0.1% riboflavin (RI)]. The surface was treated with primers and the adhesive systems were applied and restored. The samples were sectioned and tested for μTBS, NL and degree of conversion (DC). The surfaces of 2 tooth were examined under SEM to evaluate the surface characterization after erosive-cycling. For experiment 3, the teeth were randomly assigned into 18 experimental conditions according to the variables: Erosive cycling (eroded dentin with soft drink pH ≈ 2,7 and eroded eroded with citric acid pH 2.3) vs. Adhesive Systems (PBE; SBU; TEU) vs Acid pretreatment [control with 37% phosphoric acid;Phosphoric acid containing 2% chlorhexidine (CHXacid) and phosphoric acid containing 3% PA (PAacid)]. The teeth were acid-etched according to each experimental conditions, the adhesive systems were applied and the teeth were restored. The teeth were sectioned and tested for μTBS, NL and DC. Data were submitted to appropriate statistical analysis (α = 0.05). The μTBS values in eroded dentin were statistically lower than sound dentin, independent of the adhesive strategy (p < 0.01) The inclusion of primers containing collagen cross-linking agents in the eroded dentin adhesive protocol improved μTBS values (p <0.001),significantly reduced NL (p <0.004) for all the adhesives tested, as well as improved DC (p <0.03). The use of phosphoric acids containing MMPs inhibitors or collagen cross-linking agent improved μTBS values (p> 0.33), produced a significant reduction of NL (p <0.004) and improved DC (p <0.03). The application of MMP inhibitors (primer or acid etching - containing) were effective to improve the properties of the resin-eroded dentin interface.
O objetivo desse estudo foi avaliar as propriedades adesivas à dentina erosionada utilizando sistemas adesivos universais e verificar o efeito da aplicação de agentes reticuladores de colágeno ou inibidores de Metaloproteinases (MMPs) na interface resina-dentina erosionada, através de três estudos laboratoriais. Para o experimento 1, os dentes foram distribuídos aleatoriamente entre os grupos experimentais de acordo com a combinação das variáveis: superfície dentinária (controle sem erosão e erosionada) vs. sistemas adesivos (10 sistemas adesivos universais) vs.estratégia adesiva [condicionamento convencional (ER) e autocondicionante (SE)].Os sistemas adesivos foram aplicados de acordo com as especificações do fabricante e os dentes foram restaurados. Depois foram seccionados para análise da resistência de união à dentina (μTBS) e nanoinfiltração (NI). A superfície de 2 dentes foi examinada sob microscopia eletrônica de varredura (MEV) para avaliar as características da superfície após ciclagem erosiva. Para o experimento 2, os dentes foram aleatoriamente alocados em 18 condições experimentais de acordo com as variáveis: Ciclagem erosiva (dentina erosionada com coca-cola pH ≈ 2,7 e dentina erosionada com ácido cítrico pH 2,3) vs. Sistemas adesivos [Prime & Bond Elect (PBE), Scotchbond Universal Adhesive (SBU) e Tetric N-Bond Universal (TEU)] vs. Agentes de tratamento [primer contendo 6,5% de roantocianidina (PA) e primer contendo 0,1% de riboflavina (RI)]. Os sistemas adesivos foram aplicados de acordo com as especificações do fabricante após aplicação do primer e restaurados. A seguir, os dentes foram seccionados e testados para análise da μTBS, NI e grau de conversão (GC). A superfície de 2 dentes foi examinada sob MEV para avaliar as características da superfície após erosão. Para o experimento 3, os dentes foram alocados aleatoriamente dentro de 18 condições experimentais de acordo com as variáveis: Ciclagem erosiva (dentina erosionada com coca-cola pH ≈ 2,7 e dentina erosionada com ácido cítrico pH 2,3) vs. Sistemas adesivos (PBE, SBU e TEU) vs. pré-tratamento ácido [controle com ácido fosfórico 37%; Ácido fosfórico contendo 2% de clorexidina (CHXacido) e ácido fosfórico contendo 3% de PA (PAacido)]. Os dentes foram condicionados de acordo com cada grupo experimental, os sistemas adesivos foram aplicados e restaurados com resina composta. Posteriormente, os dentes foram seccionados e testados para análise da μTBS, NI e GC. Todos os dados foram submetidos a ANOVA 3 fatores e teste de Tukey (α = 0,05). Os valores de μTBS em dentina erosionada foi estatisticamente inferior à dentina sadia,independente da estratégia adesiva (p > 0,61). A inclusão de primers contendo agentes reticuladores de colágeno no protocolo adesivo a dentina erosionada,melhorou os valores de μTBS (p < 0,001), diminuiu significativamente a NI (p <0,004) para os adesivos testados, além de melhorar o GC (p < 0,03). A utilização de ácidos fosfórico contendo inibidores de MMPs ou agentes reticuladores de colágeno melhorou os valores de μTBS (p > 0,33), produziu uma redução significativa da NI (p < 0,004) e melhorou o GC (p < 0,03). Os agentes reticuladores independente do veículo (primer ou condicionamento ácido) foram eficazes para melhorar as propriedades da interface resina-dentina erosionada.
APA, Harvard, Vancouver, ISO, and other styles
14

Menegatti, Giovanna Emann Tavares. "Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/23/23134/tde-04082016-152123/.

Full text
Abstract:
A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs.
This research aims to evaluate the influence of five dentin pretreatments on microshear bond strength of four resin-modified glass ionomer (RMGI). The experiment was performed in vitro, using 200 bovine incisors. From these, there were obtained 200 dentine fragments that were randomly distributed into 20 groups (n = 10) according to the variation factors comprising five dentin treatment (control group, i.e., no treatment; Polyacrylic Acid 20%; Clearfil SE Bond; Single Bond Universal and Vitremer Primer) and four glass ionomer cements (GC Fuji II LC® CAPSULE; GC Fuji LC LINING® (Paste Pak); Vitrebond® and Vitremer). After preparation of the samples and 24h storage at 37 °C, was performed microshear test in a universal testing machine (Instron 5942 - Canton, MA, USA) with speed of 1mm/min, followed by analysis of the pattern fractures in digital microscope. Statistical analysis of the 400 results was performed by ANOVA nonparametric test for two variation factors (cement and treatment) (p <0.05%) and the post-hoc Tukey (p <0.05%). The tests demonstrated there are statistical difference between treatments, cements and between the interaction of both (p <0.0001). The Clearfil SE (X?=18,26 ± 2,78) and SingleBond (X?=17,28 ± 2,49) promoted the highest bond strength values compared to the other treatments, but showing no statistical difference between them, which represented an increase in bond strength of 121% for Clearfil SE and 109.2% for Single Bond Universal compared to control group. The Polyacrylic Acid (X?=9,94 ± 3,55) has reached intermediate values, corresponding to a 20% increase in adhesive strength compared to control group. This treatment differed significantly from the higher values, but showed no difference compared to Primer Vitremer (X?=8,91 ± 2,97). The control group (X?=8,26 ± 4,17) showed the lowest values, statistically differing from the adhesives and polyacrylic acid, but with results that matched to the treatment with Vitremer Primer. When analyzing the interaction between cement and treatment, all cements tested in this study had higher results when one of the adhesive systems was used as dentin treatment, regardless of which adhesive system. Based on these results, it could be concluded that the two adhesive systems were able to significantly improve the adhesive strength of RMGIs.
APA, Harvard, Vancouver, ISO, and other styles
15

Teixeira, Cleonice da Silveira. "Avaliação da resistência de união à dentina e análise da interface adesiva de sistemas adesivos autocondicionantes." Florianópolis, SC, 2003. http://repositorio.ufsc.br/xmlui/handle/123456789/86495.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia
Made available in DSpace on 2012-10-21T07:33:40Z (GMT). No. of bitstreams: 1 199923.pdf: 5142658 bytes, checksum: 3466433c0cd7caf76def23c5a1ef63ea (MD5)
APA, Harvard, Vancouver, ISO, and other styles
16

Barcellos, Daphne Camara [UNESP]. "Estudo longitudinal da resistência adesiva aos substratos dentários de sistemas adesivos associados ou não ao Nd:YAG Laser." Universidade Estadual Paulista (UNESP), 2013. http://hdl.handle.net/11449/101337.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-08-13Bitstream added on 2014-06-13T19:20:23Z : No. of bitstreams: 1 000757509.pdf: 3603402 bytes, checksum: 16b2be7b7c8255899a8ded28ec457d93 (MD5)
O objetivo deste estudo foi avaliar a resistência de união dos sistemas adesivos Clearfil SE Bond (CL) e Single Bond (SB) ao esmalte e dentina, em função da associação ou não do Nd:YAG Laser e do tempo de armazenagem (24 h e 12 meses). Foram utilizados 240 dentes bovinos com superfícies de esmalte ou dentina planificadas, que foram divididos em 4 grupos (n = 15) para cada substrato, de acordo com o sistema adesivo e a técnica: G1 (Controle) - CL + fotopolimerização; G2 (Controle) - SB + fotopolimerização; G3 (Experimental/Laser) - CL + Nd:YAG Laser + fotopolimerização; G4 (Experimental/Laser) - SB + Nd:YAG Laser + fotopolimerização. Para o esmalte, foi utilizada a densidade de energia = 174,16 J/cm2 e, para a dentina, a densidade de energia = 149,28 J/cm2 do Nd:YAG Laser. Foram confeccionadas restaurações de resina composta Z-350. Após armazenagem de 24 h ou 12 meses em água destilada à 37º C, foram realizadas as secções nos dentes para obtenção de amostras com área adesiva de aproximadamente 1 mm2, seguido de teste de microtração. Para cada substrato, foi realizado o teste estatístico ANOVA três fatores (Sistema adesivo X Técnica X Tempo de armazenagem), seguido do Teste de Tukey (α = 5%). Foi realizada MEV para análise complementar da interface adesiva. Para o esmalte, foram observadas diferenças significantes para a interação entre Tipo de adesivo X Técnica e Técnica X Tempo de armazenagem. Os valores de média em MPa (±Desvio-padrão) para a interação entre Tipo de adesivo X Técnica: SB/Controle = 35,78 (± 6,04)a; SB/Laser = 26,40 (± 7,25)b; CL/Controle = 26,32 (± 5,71)b; CL/Laser = 23,90 (± 7,49)b. Os valores de média em MPa (±Desvio-padrão) para a interação entre Técnica X Tempo de armazenagem: Controle/24h = 32,58 (± 6,49)a; Controle/12 meses = 29,52 (± 8,38)a; Laser/24h = 29,37 (± 5,71)a; Laser/12 meses = 20,92 (± 6,5)b. Para...
The aim of this study was to evaluate the bond strength of Clearfil SE Bond (CL) and Single Bond (SB) adhesive systems to enamel and dentin, depending on whether association with Nd: YAG Laser and storage time (24 h and 12 months). A total of 240 bovine teeth with enamel or dentin surfaces planned were prepared, which were divided into 4 groups (n = 15) for each substrate, according to the adhesive system and technique: G1 (control) - CL + photopolymerization; G2 (Control) - SB + photopolymerization; G3 (Experimental/Laser) - CL + Nd: YAG Laser + photopolymerization; G4 (Experimental/Laser) - SB + Nd: YAG Laser + photopolymerization. To the enamel, was used energy density = 174.16 J/cm2 and for dentine, energy density = 149.28 J/cm2 of Nd: YAG Laser. Composite restorations were fabricated (Filtek Z-350). After storage for 24 h or 12 months in distilled water at 37 ° C, the sections were performed on teeth to obtainment sticks with an area of about 1 mm2 adhesive interface, followed by microtensile test. For each substrate, we performed a three-way ANOVA (adhesive X Technical X Storage time), followed by the Tukey test (α = 5%). SEM analysis was performed to supplement the adhesive interface. For enamel, significant differences were observed for interaction factors Adhesive X Technique and Technique X Storage time. The mean values in MPa (± standard deviation) for interaction factor Adhesive X Technique: SB / Control = 35.78 (± 6.04) a; SB / Laser = 26.40 (± 7.25) b, CL / Control = 26.32 (± 5.71) b, CL / Laser = 23.90 (± 7.49) b. The mean values in MPa (± standard deviation) for interaction factor Technique X Storage time: Control/24h = 32.58 (± 6.49)a; Control/12 months = 29.52 (± 8.38 )a; Laser/24h = 29.37 (± 5.71)a; Laser/12 months = 20.92 (± 6.5)b. For dentin, significant differences were observed for interaction factors Technique X Storage time and Adhesive X Technique ...
APA, Harvard, Vancouver, ISO, and other styles
17

Barcellos, Daphne Camara. "Estudo longitudinal da resistência adesiva aos substratos dentários de sistemas adesivos associados ou não ao Nd:YAG Laser /." São José dos Campos, 2013. http://hdl.handle.net/11449/101337.

Full text
Abstract:
Orientador: Sérgio Eduardo de Paiva Gonçalves
Banca: César Rogério Pucci
Banca: Ricardo Scarparo Navarro
Banca: Alessandra Nara de Souza Rastelli
Banca: Maria Filomena Rocha Lima Huhtala
Resumo: O objetivo deste estudo foi avaliar a resistência de união dos sistemas adesivos Clearfil SE Bond (CL) e Single Bond (SB) ao esmalte e dentina, em função da associação ou não do Nd:YAG Laser e do tempo de armazenagem (24 h e 12 meses). Foram utilizados 240 dentes bovinos com superfícies de esmalte ou dentina planificadas, que foram divididos em 4 grupos (n = 15) para cada substrato, de acordo com o sistema adesivo e a técnica: G1 (Controle) - CL + fotopolimerização; G2 (Controle) - SB + fotopolimerização; G3 (Experimental/Laser) - CL + Nd:YAG Laser + fotopolimerização; G4 (Experimental/Laser) - SB + Nd:YAG Laser + fotopolimerização. Para o esmalte, foi utilizada a densidade de energia = 174,16 J/cm2 e, para a dentina, a densidade de energia = 149,28 J/cm2 do Nd:YAG Laser. Foram confeccionadas restaurações de resina composta Z-350. Após armazenagem de 24 h ou 12 meses em água destilada à 37º C, foram realizadas as secções nos dentes para obtenção de amostras com área adesiva de aproximadamente 1 mm2, seguido de teste de microtração. Para cada substrato, foi realizado o teste estatístico ANOVA três fatores (Sistema adesivo X Técnica X Tempo de armazenagem), seguido do Teste de Tukey (α = 5%). Foi realizada MEV para análise complementar da interface adesiva. Para o esmalte, foram observadas diferenças significantes para a interação entre Tipo de adesivo X Técnica e Técnica X Tempo de armazenagem. Os valores de média em MPa (±Desvio-padrão) para a interação entre Tipo de adesivo X Técnica: SB/Controle = 35,78 (± 6,04)a; SB/Laser = 26,40 (± 7,25)b; CL/Controle = 26,32 (± 5,71)b; CL/Laser = 23,90 (± 7,49)b. Os valores de média em MPa (±Desvio-padrão) para a interação entre Técnica X Tempo de armazenagem: Controle/24h = 32,58 (± 6,49)a; Controle/12 meses = 29,52 (± 8,38)a; Laser/24h = 29,37 (± 5,71)a; Laser/12 meses = 20,92 (± 6,5)b. Para...
Abstract: The aim of this study was to evaluate the bond strength of Clearfil SE Bond (CL) and Single Bond (SB) adhesive systems to enamel and dentin, depending on whether association with Nd: YAG Laser and storage time (24 h and 12 months). A total of 240 bovine teeth with enamel or dentin surfaces planned were prepared, which were divided into 4 groups (n = 15) for each substrate, according to the adhesive system and technique: G1 (control) - CL + photopolymerization; G2 (Control) - SB + photopolymerization; G3 (Experimental/Laser) - CL + Nd: YAG Laser + photopolymerization; G4 (Experimental/Laser) - SB + Nd: YAG Laser + photopolymerization. To the enamel, was used energy density = 174.16 J/cm2 and for dentine, energy density = 149.28 J/cm2 of Nd: YAG Laser. Composite restorations were fabricated (Filtek Z-350). After storage for 24 h or 12 months in distilled water at 37 ° C, the sections were performed on teeth to obtainment sticks with an area of about 1 mm2 adhesive interface, followed by microtensile test. For each substrate, we performed a three-way ANOVA (adhesive X Technical X Storage time), followed by the Tukey test (α = 5%). SEM analysis was performed to supplement the adhesive interface. For enamel, significant differences were observed for interaction factors Adhesive X Technique and Technique X Storage time. The mean values in MPa (± standard deviation) for interaction factor Adhesive X Technique: SB / Control = 35.78 (± 6.04) a; SB / Laser = 26.40 (± 7.25) b, CL / Control = 26.32 (± 5.71) b, CL / Laser = 23.90 (± 7.49) b. The mean values in MPa (± standard deviation) for interaction factor Technique X Storage time: Control/24h = 32.58 (± 6.49)a; Control/12 months = 29.52 (± 8.38 )a; Laser/24h = 29.37 (± 5.71)a; Laser/12 months = 20.92 (± 6.5)b. For dentin, significant differences were observed for interaction factors Technique X Storage time and Adhesive X Technique ...
Doutor
APA, Harvard, Vancouver, ISO, and other styles
18

Hanzen, Taíse Alessandra. "Efeito da incorporação de cobre nas propriedades mecânicas e adesivas à dentinas de um sistema adesivo universal." Universidade Estadual de Ponta Grossa, 2018. http://tede2.uepg.br/jspui/handle/prefix/2628.

Full text
Abstract:
Submitted by Eunice Novais (enovais@uepg.br) on 2018-09-11T14:03:43Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Taise Hanzen.pdf: 2068610 bytes, checksum: 63860393bd79b5a0ebafdc98b4fd73e2 (MD5)
Made available in DSpace on 2018-09-11T14:03:43Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Taise Hanzen.pdf: 2068610 bytes, checksum: 63860393bd79b5a0ebafdc98b4fd73e2 (MD5) Previous issue date: 2018-02-20
O propósito deste estudo in vitro foi avaliar o efeito da adição de nanopartículas de cobre em um sistema adesivo universal sobre a resistência de união (RU) e nanoinfiltração (NI) da interface resina-dentina hígida, erosionada e cariada, nas estratégias adesivas convencional (total-etch [TE]) e autocondicionante (self-etch [SE]). Bem como grau de conversão (GC), morfologia da interface de união (MI), resistência máxima à tração (RT), sorção cumulativa de água (SO) e solubilidade (SB) do sistema adesivo e radiopacidade do cobre (RC). O sistema adesivo experimental foi formulado com a adição de nanopartículas de cobre a 0,1% no adesivo Ambar Universal. Para os testes de RU e NI, 120 molares humanos foram aleatoriamente distribuídos em doze condições experimentais (n = 10) com base na combinação das variáveis: concentração de cobre [0 e 0,1%] vs. superfície dentinária (hígida, erosionada e cariada) vs. estratégias adesivas (TE e SE). Aplicado o sistema adesivo, os dentes foram restaurados com resina composta e após 24h, seccionados longitudinalmente para se obter palitos de resina-dentina (0,8 mm2), testados em tensão a 0,5 mm/min quanto a RU. Para NI, 3 palitos de cada dente foram preparados e analisados em microscopia eletrônica de varredura (MEV). Para avaliação do GC, 3 palitos de resina-dentina de cada condição experimental foram analisados por espectroscopia Raman. Para MI, 3 palitos de resina-dentina foram preparados e analisados por FEG. Para RT, 5 corpos de prova de adesivo de cada condição experimental foram testados nos tempos imediato (24h) e após 28 dias de armazenamento (n = 10). Para SO e SB, 10 corpos de prova de adesivo (n=10) de cada condição experimental foram testados durante o período de 56 dias. Para avaliação da RC, 5 corpos de prova de cada condição experimental (n = 5) foram submetidos a 5 radiografias digitais, para comparação em escala de cinza. Os dados de RU, NI e GC foram analisados por ANOVA 3 fatores, submetidos ao teste post-hoc de Tukey para múltiplas comparações. Para RT, os dados foram analisados por ANOVA 2 fatores para medidas repetidas. Os dados de RC foram analisados por ANOVA fator único. Os dados de SO e SB foram submetidos à análise por test-t pareado. A significância estatística foi predefinida em 5%. A inclusão de nanopartículas de cobre na concentração 0,1% no sistema adesivo universal aumentou os valores de RU sobre os substratos hígido e erosionado. O adesivo contendo cobre melhorou a NI no substrato hígido, em ambas as estratégias. Para RT, RC, SO e SB, a adição de cobre não apresentou diferenças estatísticas. O GC foi mais afetado em substrato erosionado quando na técnica convencional associada ao adesivo contendo cobre, que resultou na formação de tags menores e em quantidade reduzida.
The purpose of this in vitro study was to evaluate the effect of addition of copper nanoparticles on a universal adhesive system in microtensile bond strength (μTBS) and nanoleakage (NL) of sound, eroded and carious resin-dentin interface, using both self-etch [SE] and total-etch [TE] adhesive strategies. As well as degree of conversion (DC), interface micromorphology (IM), ultimate tensile strength (UTS), cumulative water sorption (WS) and solubility (So) of the adhesive system and copper radiopacity (CR). The experimental adhesive system was formulated with the addition of 0,1% copper nanoparticles on Ambar Universal. For μTBS and NL, 120 human third molars were randomly distributed in 12 experimental conditions (n=10) based on the combination of the variables: concentration of copper [0 and 0,1%] vs. dentin surface (sound, eroded and carious) vs. adhesive strategies (TE and SE). After bonding procedures and restored with composite resin, teeth were stored for 24h and then longitudinally sectioned to obtain specimens – dentin-resin sticks (0,8mm2), tested in a tension of 0,5mm/min for μTBS. For NL, 3 specimens per tooth were prepared and analyzed by scanning electron microscopy (SEM). For DC, 3 sticks of resin-dentin of each experimental condition were analyzed by Raman spectroscopy. For IM, 3 sticks of resin-dentin were prepared and analyzed by FEG. For UTS, 5 samples of each condition were tested after 24 hours and 28 days of storage (n = 10). For WS and So, 10 samples of each experimental condition (n = 10) were tested during 56 days. For radiopacity, 5 CPAs of each experimental condition (n = 5) were submitted to 5 digital radiographs, for comparison in gray scale in Adobe Photoshop Software. The data of μTBS, NL and DC (Raman) were analyzed by three-way ANOVA, submitted to Tukey's post hoc test for multiple comparisons. For UTS, data were analyzed by two-way ANOVA. For CR, data were analyzed by one-way ANOVA. The data of WS and So were evaluated by Student’s T-test. Statistical significance was set at α = 0.05. The inclusion of 0,1% of copper nanoparticles on the universal adhesive system improved μTBS values on sound and eroded substrates. The copper adhesive improved NL on sound dentin, for both strategies. For UTS, radiopacity, WS and So, the addition of copper showed no statistical difference in the results. DC was most affected by eroded dentin associated with ER strategy and adhesive containing copper, which resulted in smaller tags, in reduced quantity.
APA, Harvard, Vancouver, ISO, and other styles
19

Esteves, Stella Renata Machado Silva. "Avaliação morfológica, físico-química e mecânica longitudinal de adesivo dental experimental manipulado com diferentes concentrações de água." Universidade Estadual Paulista (UNESP), 2018. http://hdl.handle.net/11449/153050.

Full text
Abstract:
Submitted by Stella Renata Machado Silva Esteves null (stellarmse@gmail.com) on 2018-03-15T12:49:21Z No. of bitstreams: 1 tese doutorado arquivo unico.pdf: 3856356 bytes, checksum: d346b9a5b9474275d35a835574475d08 (MD5)
Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-03-16T15:51:18Z (GMT) No. of bitstreams: 1 esteves_srms_dr_sjc.pdf: 3856356 bytes, checksum: d346b9a5b9474275d35a835574475d08 (MD5)
Made available in DSpace on 2018-03-16T15:51:18Z (GMT). No. of bitstreams: 1 esteves_srms_dr_sjc.pdf: 3856356 bytes, checksum: d346b9a5b9474275d35a835574475d08 (MD5) Previous issue date: 2018-02-02
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O objetivo desse estudo foi avaliar um adesivo experimental com diferentes concentrações de água, bem como sua degradação morfológica, química, física e mecânica. A primeira etapa envolveu a manipulação do adesivo experimental contendo 45/55% de HEMA e BisGMA, 0.5% de canforoquinona, 0.5% EDMAB e 1% de DPIHP. Foram incorporadas diferentes concentrações de água a partir dessa formulação adesiva (0, 10 e 16%). Os modelos adesivos foram fotopolimerizados e as análises iniciais realizadas: Morfológicas (Estereomicroscopio e Micro-xct); Físicas (Rugosidade-Ru, Sorção-Sor, Solubilidade-Sol); Químicas (Grau de conversão-GC, Mapeamento do espécime com 16% de água e os monômeros liberados pela CLAE); Mecânicas (Resistência flexural-RF, Módulo de elasticidade-ME e Resistência a compressão-RC). Em seguida os espécimes foram divididos conforme a solução de envelhecimento (água, etanol e acetona). Foram realizadas novas análises após o envelhecimento por 2 e 84 dias. Os testes estatísticos ANOVA e Tukey (5%) foram realizados. Os resultados iniciais, sem o envelhecimento, mostraram que as diferentes concentrações de água influenciam as propriedades dos adesivos. Na análise morfológica notou-se a presença de bolhas no espécime com 16% de água. Para a Ru e GC os maiores valores foram encontrados para os espécimes com mais água em sua composição e os menores para 0%. Já nas análises mecânicas, para RF e ME os espécimes com 10% de água foram mais resistentes; e em RC os espécimes com 16% foram menos resistentes. Após o envelhecimento notou-se trincas nos espécimes 0% e 16% na solução de acetona. Nos testes físicos, os espécimes com 16% absorveram mais solução; o etanol mostrou menores valores de solubilidade; Para Ru a água e a acetona diferiram em todas as concentrações e períodos, o mesmo ocorrendo para as concentrações 0 e 16%. Nos testes químicos o GC não foi alterado pelo envelhecimento. O mapeamento na amostra com 16% de água mostrou que inicialmente perto do poro o GC é menor e a quantidade de HEMA é maior; longe do poro a relação é inversa. Porém, após o envelhecimento, o GC próximo ao poro se tornou similar ao distante do poro. Através da CLAE observou-se uma maior liberação de componentes do espécime com 0% de água que os espécimes com 10% e 16%. Os testes mecânicos mostraram que o envelhecimento em acetona foi mais prejudicial que em água. Para a RF e ME os espécimes com 0% de água foram mais afetados que os espécimes com 10% e 16% em 2 e 84 dias. Para a RC após 2 dias o espécime com 16% foi mais afetado que 0 e 10%, no entanto, após 84 dias o espécime com 0% foi mais afetado pelo envelhecimento. Pode-se constatar que a quantidade de água e o tipo de envelhecimento afetam as propriedades dos sistemas adesivos baseados na composição 45/55% HEMA/BisGMA.
The aim of this study was evaluated an experimental adhesive with different water content, as well the degradation morphological, physical, chemical and mechanical. Firstly the dental adhesive was manipulated with 45/55% of HEMA and BisGMA, 0.5% of CQ, 0.5% EDMAB e 1% of DPIHP. Was added different water content (0, 10 and 16%). The adhesive model was cured and the analysis was done: Morphological (Stereomicroscope and Micro-xct); Physical (Surface Roughness), Sorption, Solubility); Chemical (Degree of convertion, Map of the pore on 16% water content sample and the released monomers- HPLC); Mechanicals (Flexural strength, Modulus of elasticity and Compressive strength). After the these analyzes, the samples were divided to each evaluation into 3 groups according to solution for performed ageing (water, ethanol and acetone). Further analyzes were performed after aging for 2 and 84 days. Statistical tests of ANOVA and Tukey (5%) were performed. Initial results, without aging, showed that the different water content influence adhesive properties. In the morphological analysis, bubbles were present on the sample with 16% water. For Ru and DC all specimens differed from each other, with the highest values for the specimens with 16% and the lowest to 0%. In the mechanical analyzes, for RF and ME the specimens with 10% water were more resistant; and in RC the specimens with 16% were less resistant. After aging it is possible notice cracks on the border of specimens 0% and 16% in the acetone. In the physical tests, the specimens with 16% absorbed more solution; ethanol showed lower values of solubility; For Ru, water and an acetone are differed in all concentrations and periods, the same for the concentration 0 and 16%. In the chemical tests DC was not altered by aging. The mapping in the sample with 16% of water showed that near to the pore the DC is smaller and a quantity of HEMA is larger; far from the pore this relation is inverse. However, after aging solutions, the DC near the pore became similar to the far from pore. Through HPLC was possible observed that release more components of the sample with 0% than 10% and 16%. The mechanical tests showed that the acetone damage more samples than water. For an RF and ME the specimens 0% were more affected than 10% and 16% after 2 and 84 days. For a RC after 2 days the sample with 16% was more affected than 0 and 10%, however, after 84 days the specimen with 0% was more affected by aging. It can be seen that the amount of water and the type of aging affect the adhesive properties of the database systems based on the 45/55% HEMA / BisGMA composition.
APA, Harvard, Vancouver, ISO, and other styles
20

Antunes, Alberto Nogueira da Gama. "Avaliação de adesivos autocondicionantes contemporâneos = efetividade da união dentina-adesivo em função do tempo de armazenamento em água." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288198.

Full text
Abstract:
Orientador: Mário Fernando de Góes
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-18T00:31:21Z (GMT). No. of bitstreams: 1 Antunes_AlbertoNogueiradaGama_D.pdf: 9481155 bytes, checksum: a267a90e105bb7a35b7e5367aa915a36 (MD5) Previous issue date: 2011
Resumo: O objetivo do estudo foi avaliar a resistência à tração e nanoinfiltração de adesivos autocondicionantes unidos à dentina em função do período de armazenamento em água. Cinquenta molares humanos foram aleatoriamente distribuídos em cinco grupos com 10 dentes cada, de acordo com o adesivo: Single Bond 2, Easy One, Silorane (3M ESPE), Bond Force (Tokuyama) e Adhese One (Ivoclair Vivadent). O esmalte oclusal foi seccionado para obter uma superfície plana em dentina. Os adesivos foram aplicados sobre a superfície da dentina de acordo com as orientações de cada fabricante. Um bloco de resina composta foi construído sobre cada dente, armazenados por 24 horas em água a 37ºC, seguidos pelo seccionamento e obtenção de corpos-de-prova com o formato de palitos com área de secção transversal de 0,8±0,1mm2. Foram usados 5 palitos de cada dente (n=5) em cada período de armazenamento, 24h, 3 e 6 meses, para o teste de resistência à tração (Instron, 0,5mm/minuto). O padrão de fratura foi analisado em microscópio eletrônico de varredura. Três palitos de cada grupo (n=5), em cada período de armazenamento, foram imersos em prata amoniacal para a análise da região da união. Os valores médios obtidos no ensaio de tração (MPa) e nanoinfiltração (%) foram submetidos à Análise de Variância e teste de Fischer (p<0,05). Os valores da resistência à tração (MPa) e nanoinfiltração (%) nos períodos de 24h, 3 e 6 meses foram, respectivamente: Single Bond 2 (48,78, 37,24 e 30,32), (4,78, 4,79 e 6.14); Easy One (48,55, 39,71 e 29,96), (3,22, 2,51 e 4,87); Silorane (41,77, 36,5 e 26,27), (0,77, 0,79 e 2,18); BondForce (39,10, 34,44 e 22,54), (4,28, 4,67 e 13,10); Adhese One (24,65, 24,48 e 16,69), (3,14, 2,93 e 6,74). A resistência à tração do Adhese One foi estatisticamente diferente e inferior aos demais adesivos nos 3 períodos de armazenamento. Single Bond 2, Silorane e BondForce apresentaram resistência à tração estatisticamente diferentes nos períodos de 24h e 6 meses, enquanto que o Easy One e o Adhese One não foram diferentes estatisticamente nos mesmos períodos. O valor médio da nanoinfiltração do Silorane foi inferior e diferente estatisticamente em relação aos demais adesivos, que não apresentaram diferenças entre si no período de 24h. O adesivo BondForce apresentou o maior valor de infiltração de prata em relação aos demais adesivos com a exceção do Adhese One. Os adesivos Single Bond 2, Easy One e Silorane não apresentaram diferenças estatisticamente significantes entre si. O Silorane, BondForce e Adhese One apresentaram valores estatisticamente diferentes em relação ao período de 24h e 6 meses de armazenamento, enquanto que o Single Bond 2 e o Easy One não apresentaram diferenças no mesmo período de tempo. A fratura coesiva na camada de adesivo foi o padrão predominante para os adesivos autocondicionantes nos diferentes tempos de armazenamento. O Single Bond 2 mostrou um padrão de fratura misto, distribuído nas regiões da base da camada híbrida, coesiva no adesivo, dentina, camada híbrida e resina composta nos 3 períodos de armazenamento
Abstract: The aim of this study was to evaluate the tensile strength and nanoleakage of adhesives to dentin surface according to water storage period. Fifty human molars were randomly assigned to five groups of 10 teeth each, according to the adhesive Single Bond 2, Easy One, Silorane (3M ESPE), Bond Force (Tokuyama) and Adhese One (Ivoclair Vivadent). The occlusal enamel was sectioned to obtain a flat dentin surface. The adhesives were applied on the dentin surface according to manufacturer' s instruction. A composite block was built-up on each flat dentin, stored for 24h in water at 37°C, followed by sectioning to obtain beams with crosssectional area of 0.8 ± 0.1mm2. It was used 5 beams from each tooth (n=5) at each storage period - 24h, 3 and 6 months - to evaluate the tensile strength (Instron, 0.5mm/minute). The fracture pattern was analyzed in scanning electron microscope. Three beams of each group (n=5) in each storage period were immersed in ammoniacal silver nitrate to evaluate the nanoleakage. The average values obtained in tensile test (MPa) and nanoleakage (%) were submitted to ANOVA and Fischer's test (p<0.05). The tensile strength (MPa) and nanoleakage (%) values for 24h, 3 and 6 months were: Single Bond 2 (48.78, 37.24 and 30.32), (4.78, 4.79 and 6.14); Easy One (48.55, 39.71 and 29.96), (3.22, 2.51 and 4.87); Silorane (41.77, 36.5 and 26, 27), (0.77, 0.79 and 2.18); BondForce (39.10, 34.44 and 22.54), (4.28, 4.67 and 13.10); Adhese One (24.65, 24.48 and 16.69), (3.14, 2.93 and 6.74). The tensile strength of Adhese One was inferior and statistically different from the other groups on the three periods of storage. Single Bond 2, Silorane Bond Force 24h tensile strength values showed statistically difference to the 6 months groups, while the Easy One and One Adhese were not statistically different in the same periods. The nanoleakage of Silorane was lower and statistically different compared to the other adhesives, which do not differ from each other within 24 hours. The adhesive Bond Force showed the highest infiltration of silver compared to Easy One and Silorane while it was not statistically different from Single Bond 2 and Adhese One other adhesives with the exception of Adhese One and Single Bond 2. The Silorane, BondForce Adhese One showed 6 months nanoleakage values statistically different from 24h, but Single Bond 2 and Easy One presented no differences in the same period. A cohesive failure in adhesive layer was the predominant pattern of self-etching adhesives in three storage periods. The Single Bond 2 showed a mixed fracture pattern, distributed in hybrid layer base, cohesive in adhesive, dentin, hybrid layer and composite resin in three storage periods
Doutorado
Materiais Dentarios
Doutor em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
21

Pazinatto, Flavia Bittencourt. "Influência do posicionamento do espécime na resistência adesiva à dentina e na espessura da camada de sistemas adesivos." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/25/25131/tde-07022007-144601/.

Full text
Abstract:
Investigou-se a influência da inclinação das paredes de dentina (paralela ou perpendicular à ação da gravidade) e da variação regional dos espécimes (terços cervical ou oclusal) na resistência adesiva e na espessura da camada de adesivo. Vinte e cinco molares humanos foram seccionados no sentido mésio-distal e paralelamente ao seu longo eixo, obtendo-se secções vestibulares e linguais, as quais foram lixadas produzindo-se superfícies planas de dentina. Sistemas adesivos (Adper Single Bond-SB e Prime & Bond 2.1- PB2.1) foram aplicados na dentina, ora paralelamente ora perpendicularmente à ação da gravidade, padronizando-se o volume de adesivo (3,5 µl por gota) através do uso de uma micropipeta e seguindo-se as instruções dos fabricantes. Os grupos de estudo foram: 1A (SB, paralelo), 1B (SB, perpendicular), 2A (PB2.1, paralelo) e 2B (PB2.1, perpendicular). Após 24h de armazenamento em água deionizada a 37°C, espécimes foram preparados na forma de palitos de dentina com área adesiva de 0,8 mm2, aproximadamente. Na seqüência, foi determinada a espessura do adesivo de cada espécime, em micrômetros (µm), sob microscopia óptica (200X de aumento) e auxílio do programa Image Pro-Plus 4.5. Posteriormente, os espécimes foram submetidos à microtração sob velocidade de 0,5 mm/min. Todos os espécimes fraturados foram examinados sob microscopia óptica (40X de aumento) para a determinação dos planos de fratura. Os dados coletados foram submetidos aos testes ANOVA a 1 e 2 critérios e SNK (? = 0,05). Para determinação da correlação entre resistência adesiva e espessura do adesivo foi utilizado o teste de Correlação de Pearson. Os valores médios (MPa±d.p.) de resistência adesiva dos grupos 2A (52,93±15,19) e 2B (52,27±16,54) foram superiores àqueles dos grupos 1A (39,09±12,90) e 1B (32,94±12,42), independente da inclinação das paredes de dentina dos mesmos. Não houve diferença nos valores de resistência adesiva à dentina, independente da variação regional do espécime. Os valores médios (µm±d.p.) de espessura da camada de adesivo dos grupos 1A (11,24±2,92) e 1B (18,11±7,31) foram superiores àqueles dos grupos 2A (4,20±1,81) e 2B (3,87±1,29) (p > 0,05). O grupo 1B promoveu os maiores valores de espessura de adesivo, seguido do grupo 1A. As espessuras do adesivo nos grupos 2A e 2B apresentaram-se similares entre si. Houve influência da variação regional do espécime na espessura de adesivo somente para o grupo 1B. Não houve correlação entre resistência adesiva e espessura de adesivos para ambos SB e PB2.1 (r = -0,224, p = 0,112 e r = 0,099, p = 0,491, respectivamente). Conclui-se que a influência da inclinação das paredes de dentina e da variação regional dos espécimes na espessura da camada de adesivo é material-dependente, porém não influem na resistência adesiva dos sistemas adesivos à dentina.
To determine the effect of the inclination of dentin surfaces (parallel or perpendicular to the force of gravity) and the regional variation of specimens (cervical or occlusal thirds) on the dentin bond strength and adhesive layer thickness. Twenty-five extracted human molars were sectioned in a mesio-distal direction to expose flat dentin. Standardized drop volumes of adhesive systems (Single Bond-SB and Prime & Bond 2.1-PB2.1) were applied to dentin according to manufacturers instructions. Teeth were randomly divided into the following groups: 1A (SB, parallel), 1B (SB, perpendicular), 2A (PB2.1, parallel) and 2B (PB2.1, perpendicular). Teeth were stored in 37°C distilled water for 24h and then serially sectioned to obtain sticks with cross-sectional area of approximately 0.8 mm2 for microtensile bond strength test (MTBS). The thickness of adhesive layer of the MTBS specimen was determined in a light microscope at 200X magnification. Forty-eight hours after adhesion procedures the specimens were subjected to MTBS at a crosshead speed of 0.5 mm/min. After testing, the fracture modes of each specimen were determined by examination under a 40X magnification. One and two-way ANOVA and Student- Newman-Keuls-SNK tests were performed do determine differences in MTBS and in adhesive layer thickness among groups. The correlation between MTBS and adhesive layer thickness was compared with Pearson Product Moment Correlation ('alfa' = 0.05). Mean values (MPa±s.d.) for bond strength were higher for groups 2A (52.93±15.19) and 2B (52.27±16.54) than for groups 1A (39.09±12.90) and 1B (32.94±12.42), regardless of the position of dentin surfaces. There was no difference in MTBS, despite the regional variation of specimens. The thickness of adhesive systems (µm±s.d.) was higher for groups 1A (11.24±2.92) and 1B (18.11±7.31) than those for groups 2A (4.20±1.81) and 2B (3.87±1.29). Group 1B provided the greater mean values of adhesive thickness followed by the Group 1A. Similar adhesive thicknesses were found for Groups 2A and 2B, but significantly lower than the other groups. There was a significant influence of the regional variation of specimens on the adhesive thickness of group 1B. No correlation was found between bond strength and adhesive layer thickness for both SB and PB 2.1 (r = -0.224, p = 0.112 and r = 0.099, p = 0.491, respectively). The inclination of dentin surface and the regional variation of specimens on the adhesive layer thickness are materialdependent. These variables do not influence the adhesive systems bond strength to dentin.
APA, Harvard, Vancouver, ISO, and other styles
22

Valeretto, Thiago Majolo. "Avaliação da influência de agentes químicos previamente à aplicação de sistemas adesivos autocondicionantes na resistência adesiva à dentina." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/25/25148/tde-23042014-095854/.

Full text
Abstract:
Com os sistemas adesivos autocondicionantes, o uso prévio do ácido fosfórico passou a ser dispensado em dentina. Assim, outras soluções foram propostas a fim de se promover uma limpeza da cavidade e otimizar um melhor embricamento do adesivo ao substrato. O objetivo deste estudo foi avaliar a influência de soluções químicas à adesão à dentina bovina, por meio da resistência ao microcisalhamento, de três sistemas adesivos autocondicionantes em função do tempo. Duzentos e quarenta incisivos bovinos foram incluídos, desgastados e polidos em série com lixas de carbeto de silício, obtendo uma superfície planificada de dentina de 10 mm de diâmetro. Os espécimes foram divididos aleatoriamente em 4 grupos, de acordo com a solução aplicada: SF- aplicação de soro fisiológico com 0,9% NaCl (grupo controle); HS- desproteinização com hipoclorito de sódio a 5%, por 2 minuto e HSAA- hipoclorito de sódio a 5%, por 2 minuto seguida da aplicação de ácido ascórbico (ascorbato) a 10%, por 1 minuto; CHX- aplicação de solução clorexidina a (2% por 1 minuto). Às superfícies preparadas foram aplicados três sistemas adesivos autocondicionantes, por grupo - Optibond All-in-One (KERR), Filtek P90-System Adhesive (3M-ESPE) e Adper SE (3M-ESPE), todas seguidas da inserção de resina composta (Filtek Z250 ou Filtek P90). Metade dos espécimes de cada grupo foram armazenados por 24 horas e metade por 6 meses. Após esses períodos, os espécimes foram submetidos ao teste de microcisalhamento, em uma máquina de ensaios universal (Emic, na velocidade de 0,5mm/min). Os dados foram avaliados estatisticamente através de análise de variância (ANOVA) a três critérios e testes de comparações múltiplas de Tukey ambos considerando a=0,05. O adesivo Filtek P90-System Adhesive foi o único que manteve a resistência adesiva após o envelhecimento, porém, os dois tratamentos de superfície contendo hipoclorito de sódio influenciaram negativamente. Já com a clorexidina não houve diferença estatisticamente significante comparada ao grupo controle. O adesivo OptiBond All- In-One (Kerr) foi influenciado positivamente pelo hipoclorito de sódio e hipoclorito de sódio mais ascorbato, no tempo de 24 horas. Sendo de iqual resultado com o envelhecimento em solução aquosa. Adper SE (3M-ESPE) sofreu influência dos tratamentos à base de hipoclorito de sódio. O melhor resultado, comparando dois tratamentos com hipoclorito, após o envelhecimento, foi obtido pelo tratamento com o hipoclorito de sódio mais ascorbato sendo estatisticamente idêntico ao grupo controle. Foi concluído que os tratamentos de superficie influenciam na resistência adesiva dos adesivos testados. A clorexidina possibilitou os melhores resultados em quase todos os testes.
With the Self-etching adhesives, acid-etching with phosphoric acid has to be dispensed in dentin. Than, other solutions have been proposed in order to promote the cavity cleaner and improvement in bonding effectiveness. The aim of this study was to investigate the microshear bond strength, with the influence of chemical solutions and time, in three adhesive systems used on bovine dentin. Two hundred and forty bovine incisors were included, and the surface was polished in series with silicon carbide paper, getting flattened dentin surface of 10 mm in diameter. The specimens were randomly divided into four groups, according to the applied solution: SF- saline solution with 0.9% NaCl (control group), HS-deproteinization with sodium hypochlorite at 5%, for 2 minutes and HSAA- sodium hypochlorite 5% for 2 minutes followed by the application of ascorbic acid (ascorbate) and 10% for 1 minute;CHXapplication of chlorhexidine solution (2% for 1 minute). Were applied to surfaces prepared three adhesive systems, per group - Optibond All-in-One (Kerr), Filtek-P90 System Adhesive (3M-ESPE) and Adper SE (3M-ESPE), all followed by the insertion of composite resin ( Filtek Z250 and Filtek P90). Half of the specimens of each group / treatment were stored for 24 hours and half for six months. After these periods were tested using the microshear in a universal testing machine (Emic, the speed of 0.5 mm / min). Results were submitted to three way ANOVA and TUKEY test multiple comparison both considering a = 0.05. The adhesive Filtek P90 System Adhesive was the one who kept the bond strength after aging, however, the two surface treatments containing sodium hypochlorite influenced negatively. With chlorhexidine, there was no statistically significant difference compared to the control group. The adhesive OptiBond All-in-One (Kerr) was affected by the sodium hypochlorite, sodium hypochlorite more ascorbate, at 24 hours. As a result of iqual with aging in aqueous solution. Adper SE (3M-ESPE) was influenced by the treatments using sodium hypochlorite. The best result, comparing two treatments with hypochlorite, after aging, was obtained by treatment with sodium hypochlorite more ascorbate was statistically identical to the control group. It was concluded that the influence of surface treatments on bond strength of adhesives tested. The chlorhexidine resulted in better results in almost every test.
APA, Harvard, Vancouver, ISO, and other styles
23

Isolan, Cristina Pereira. "União adesiva à dentina sadia e dentina afetada por cárie." Universidade Federal de Pelotas, 2016. http://repositorio.ufpel.edu.br:8080/handle/prefix/3551.

Full text
Abstract:
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-19T14:18:07Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) União adesiva à dentina sadia e dentina afetada por cárie.pdf: 2924942 bytes, checksum: 46fc75de5cf29a28244831e9fc608962 (MD5)
Made available in DSpace on 2017-06-19T14:18:07Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) União adesiva à dentina sadia e dentina afetada por cárie.pdf: 2924942 bytes, checksum: 46fc75de5cf29a28244831e9fc608962 (MD5) Previous issue date: 2016-02-25
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
O objetivo deste trabalho, dividido em três estudos, foi avaliar a resistência de união de sistemas adesivos comerciais e experimentais a diferentes substratos, dando ênfase à dentina afetada por cárie (CAD), por ser um substrato bastante comum na prática clínica e ainda com muitos questionamentos a serem esclarecidos. Materiais e Métodos: No estudo 1, foi comparada a resistência de união entre um Adesivo Universal (Scotchbond Universal, 3 M ESPE) e outros Sistemas adesivos comerciais aplicados a diferentes substratos: esmalte, dentina hígida (SoD), resina composta e porcelana. Espécimes de cada substrato foram confeccionados para o teste de microtração (SoD e resina composta) ou teste de cisalhamento (esmalte e cerâmica). Os dados foram analisados por meio de ANOVA uma via e teste de Tukey (a = 0,05). No estudo 2 foi avaliada, por meio de uma revisão sistemática da literatura, a união de adesivos aplicados à SoD em comparação à CAD. Uma pesquisa no PubMed, Scopus e Web of Science foi realizada por dois revisores independentes. Foram identificados 2.260 artigos únicos e, após avaliação dos títulos/resumos, 65 artigos foram selecionados para leitura completa, dos quais 40 foram incluídos. Os dados foram extraídos e categorizados de acordo com o sistema adesivo utilizado (convencional ou autocondicionante). As médias de resistência de união de ambos substratos foram comparadas utilizando um modelo estatístico de efeitos randômicos (Review Manager Version 5.1). A heterogeneidade estatística foi testada usando teste I2. Uma análise de subgrupo foi realizada considerando métodos de remoção de tecido cariado. O estudo 3 avaliou a resistência de união imediata, e após período de 6 meses, de adesivos experimentais autocondicionantes à SoD e CAD; tais adesivos continham três diferentes concentrações do monômero ácido GDMA-P. Biofilmes de microcosmos originados de saliva humana foram formados sobre discos de dentina e cultivados em anaerobiose por 14 dias. Doze grupos foram definidos com diferentes concentrações de GDMA-P (5%, 20% e 35%), tipo de dentina e período de estocagem. Discos de dentina bovina para cada grupo (n=10) foram incluídos em resina acrílica e o adesivo foi aplicado. Uma matriz de elastômero foi usada para obtenção de dois cilindros (diâmetro 1,5 mm, espessura 0,5 mm) de resina composta na superfície. Os cilindros foram submetidos ao teste de resistência de união após 24h e após 6 meses em uma máquina de Ensaio Universal. Os dados foram analisados por ANOVA e Student-Newman-Keuls (5%). Resultados: No estudo 1, os resultados foram satisfatórios para adesão a cerâmica, resina composta, esmalte e dentina, esta última tanto com a técnica de condicionamento total, como com a autocondicionante. No estudo 2, os sistemas adesivos convencional e autocondicionante aplicados à SoD apresentaram melhores resultados de resistência de união quando comparados aos da CAD. O método 10 utilizado para a remoção de cárie também afetou a resistência de união. No estudo 3, a concentração de GDMA-P e o tipo de substrato interferiram na resistência de união à dentina. Conclusão: Variáveis na formulação dos adesivos interferem no seu desempenho de união a diferentes substratos. Estudos ainda devem ser realizados para se desenvolver uma formulação tida como ideal para substratos mais complexos como CAD.
The main objective of this investigation, divided into three studies, was to assess the bonding strength of commercial and experimental adhesive systems to different substrates, emphasizing caries-affected dentin (CAD), as it is a fairly common substrate in clinical practice and with many doubts to be clarified. Materials and methods: Study 1, to compare the bonding ability of a universal dental adhesive (Scotchbond Universal, 3 M ESPE) to other commercial dental bonding agents applied to different substrates: enamel, sound dentin (SoD), resin composite, and porcelain. Specimens of each substrate were prepared for microtensile bond strength test/µTBS (SoD and composite) or shear bond test/SBS (enamel and porcelain). Data were analyzed using One-Way ANOVA and Tukey’s test (a=0.05). In study 2, the adhesive performance (bonding ability) of dental adhesives applied to sound dentin (SoD) in comparison to caries-affected dentin (CAD) was evaluated through a systematic review of dental literature. A structured search in three international databases (Medline/PubMed, Scopus, and Web of Science) was carried out by two independent reviewers. A total of 2.260 unique articles were found. After excluding articles by title and reading of the abstract, 65 articles were selected for full-text reading, and 40 studies were included in the review. Data were extracted and categorized according to the adhesive system used (etch-and-rinse or self-etch adhesives). The bonding strength mean of the two substrates tested were compared using a randomized effects model (Review Manager Version 5.1). Statistical heterogeneity was tested by using I2 test. A subgroup analysis was carried out to explore the heterogeneity considering the methods used for the removal of caries. Study 3 evaluated immediate and long term shear bonding strength of experimental self-etch adhesives, containing three different concentrations of the acidic monomer GDMA-P, to SoD and CAD. Microcosm biofilms were formed over dentin discs and cultivated under anaerobic conditions for 14 days. Twelve groups were defined by different GDMA-P concentrations (5%, 20%, and 35%), dentin type and storage time. Bovine dentin discs for each group (n=10) were included in acrylic resin and the adhesives were applied. An elastomer mold with cylindrical orifices (1.5 mm diameter) was used to obtain two cylinders of composite resin on the surface. After a period of 24h and 6 months the cylinders were subjected to bond strength test in a mechanical testing machine. Data were analysed by ANOVA and Student-Neuman-Keuls’ test (5%). Results: In Study 1, the results were considered satisfactory for adhesion to ceramic, composite, enamel and dentin, and the latter for both the total etching and self-etching technique. In study 2, the conventional and self-etching adhesive systems applied to SoD showed better bond strength results compared to CAD. The method used for removing carious also affected the bond strength. In 12 study 3, the bond strength to dentin varied with the concentration of GDMA-P and type of substrate. Conclusion: Variables in the formulation of adhesives have impact in their bonding performance to different substrates. Further studies are still necessary to develop an ideal formulation for more complex substrates such as CAD.
APA, Harvard, Vancouver, ISO, and other styles
24

Mazur, Rui Fernando [UNESP]. "Análise da resistência adesiva à dentina de diferentes sistemas adesivos pelo teste de microtração e microscopia eletrônica de varredura." Universidade Estadual Paulista (UNESP), 2003. http://hdl.handle.net/11449/101404.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-11-10Bitstream added on 2014-06-13T20:41:47Z : No. of bitstreams: 1 mazur_rf_dr_arafo.pdf: 2691655 bytes, checksum: aa6766566238765dc0a1f4d5cb633eda (MD5)
O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de adesiva pelo teste de microtração de dez sistemas adesivos diferentes. Os sistemas adesivos One Up Bond F - Tokuyama, Clearfil SE Bond - Kuraray, Adper Prompt L-Pop, Single Bond - 3M/ESPE, One Step - Bisco, One Step Plus - Bisco, Prime&Bond NT - Dentsply, Excite - Vivadent, Scotchbond Multi - Uso - 3M/ESPE e All Bond 2 - Bisco. Para a realização do teste foram utilizados quarenta dentes molares hígidos, sendo que destes dentes dez foram utilizados para a microscopia eletrônica de varredura. Para a realização do teste de microtração os dentes foram cortados na superfície oclusal com disco diamantado e posteriormente foram desgastados com discos de lixa. Posteriormente as amostras foram restauradas com os respectivos sistemas adesivos e resina composta Z-100 com tempo de polimerização de 40 segundos cada incremento. Após vinte e quatro horas de armazenagem em temperatura de 37ºC os dentes foram seccionados com disco diamantado com finalidade de obter palitos com área de 1,0 +- 0,2 mm2. Após o corte os palitos foram armazenados em temperatura de 37ºC por vinte e quatro horas e em seguida foram levados para a máquina de ensaio universal EMIC 500 DL onde os palitos foram tracionados com velocidade de 1 mm/min. Os resultados foram analisados pelo através dos testes de normalidade de Lilliefors e de homogeneidade de variância de Bartlett. Quando alguns dos pressupostos não se verificaram, utilizou-se o teste não paramétrico de Kruskal - Wallis. Os resultados obtidos foram em ordem decrescente de 36,73 +- 10,52 para o sistema adesivo One Up Bond F, seguido do sistema de três etapas All Bond 2 com 34,29 +- 12,63 para o sistema adesivo One Step Plus foi de 33,18 +- 11,33 para o sistema Adper Prompt L-Pop de 31,76 +- 11,3, sistema One Step de 29,02 +- 11,28, para o... .
The aim of this study was to analyze the bond strength of ten adhesive systems: One Up Bond F - Tokuyama (OU); Adper Prompt L-Pop - 3M-ESPE (AP); Clearfil SE Bond - Kuraray CO. (SE); Prime Bond NT - Caulk-Dentsply (NT); Single Bond - 3M-ESPE (SB); One Step - Bisco (OS); One Step Plus - Bisco (OP); Excite - Vivadent (EX); Scotchbond Multi - Purpose (SMP) e All Bond 2 - Bisco (AB). Methods: Forty freshly extracted human teeth were transversely wetcut using a diamond disk in order to expose the occlusal dentin surface. Then the adhesive systems were applied according to the manufacturer's instruction. The teeth were restored with composite resin Z-100 (3M) and stored in distilled water at 37ºC for 24 hours. A slow-speed diamond disk was used to prepare microtensile test specimens, with a bonded area of 1,00 +- 0,2 mm2. Each group was composed of thirty sticks, which were stored in distilled water at 37ºC for 24 hours. The sticks were bonded on a universal testing machine at a cross head speed of 1 mm/min. The following results demonstrate values microtensile bond strengths in MPa. Data were statistically analyzed by Kruskal-Wallis Test (p<-0.05). The bond strength values were 36,73 +- 10,52 for One Up Bond F, 34,29 +- 12,63 for All Bond 2, 33,18 +- 11,33 for One Step Plus, 31,76 +- 11,3 for Adper Prompt L-Pop, 29,02 +- 11,28 for One Step, 28,82 +- 14,74 for Single Bond, 28,08 +- 12,09 for Clearfil SE Bond, 26,31 +- 9,02 for Scotchbond Multi - Purpose, 21,35 +- 10,22 for Prime&Bond NT and 19,52 +- 10,08 for Excite. Ten teeth were analysed by SEM and all of them showed resin into the dentin tubules. Most of fractures were adhesive in the composite/teeth interface. One up bond F (OU) resulted in higher bond strength when compared to all the other systems tested and Excite resulted in lower bond strength. Self-etching systems were not statistically... (Complete abstract, click electronic address below).
APA, Harvard, Vancouver, ISO, and other styles
25

Pinhão, Marcelo José Braga. "Análise molecular vibracional da interface adesivo-dentina após aplicação de múltiplas camadas de sistemas adesivos convencionais de dois passos." Universidade do Estado do Rio de Janeiro, 2008. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=3488.

Full text
Abstract:
O propósito do presente estudo foi analisar o efeito da aplicação de múltiplas camadas consecutivas de dois sistemas adesivos convencionais de dois passos na difusão resinosa e padrão de distribuição dos componentes monoméricos resinosos. Dezesseis terceiros molares humanos hígidos foram tratados com os sistemas adesivos convencionais de dois passos de acordo com as instruções dos fabricantes ou com aplicações em múltiplas camadas consecutivas. Os espécimes foram seccionados paralelamente aos túbulos dentinários e as superfícies submetidas ao polimento com lixas 600, 1200, 1800, 2000 e 4000. Os espectros Raman foram coletados ao longo de uma linha perpendicular a interface adesivo-resina em intervalos de 1 ou 2 m. As medidas de difusão da resina adesiva e distribuição dos componentes monomériccos foram avaliadas pelos picos Raman de 1113 cm-1, 1609 cm-1 e 1454 cm-1. O gradiente de desmineralização usado na determinação da região de hibridização foi avaliado pelo pico de 960 cm-1 da apatita. De acordo com os resultados obtidos, a aplicação de múltiplas camadas apresentou uma tendência de homogeneização dos componentes poliméricos, dependente da composição química da resina adesiva.
The present study analyzed the effect of multiple consecutive adhesive coatings on the pattern of resin diffusion and distribution of monomer components through demineralised dentin after application of two total-etch adhesives. Resin bonded dentin specimens were prepared using two total-etch adhesives (Prime&Bond NT2.1 and Adper Single Bond). The specimens were sectioned parallel to dentinal tubules and the surfaces were polished using 600, 1200, 1800, 2000 and 4000 silicon-carbide papers. Raman spectra were recorded along a line perpendicular to the dentin-resin interface in steps of 1 or 2 m. The measurements of resin diffusion and distribution of monomer components were made on a relative basis by comparing the bands 1113, 1609 and 1454 cm-1. The gradient of dentin demineralization, designed to 960 cm-1, was used to determine the extent of hybridization. From the results of the present study the application of multiple coatings of adhesive showed a trend to produce a homogeneous hybrid layer.
APA, Harvard, Vancouver, ISO, and other styles
26

Mazur, Rui Fernando. "Análise da resistência adesiva à dentina de diferentes sistemas adesivos pelo teste de microtração e microscopia eletrônica de varredura /." Araraquara : [s.n.], 2003. http://hdl.handle.net/11449/101404.

Full text
Abstract:
Orientador: José Roberto Cury Saad
Banca: Marcelo Ferrarezi de Andrade
Banca: Welingtom Dinelli
Banca: Rodrigo Nunes Rached
Banca: Paulo Sérgio Quagliatto
Resumo: O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de adesiva pelo teste de microtração de dez sistemas adesivos diferentes. Os sistemas adesivos One Up Bond F - Tokuyama, Clearfil SE Bond - Kuraray, Adper Prompt L-Pop, Single Bond - 3M/ESPE, One Step - Bisco, One Step Plus - Bisco, Prime&Bond NT - Dentsply, Excite - Vivadent, Scotchbond Multi - Uso - 3M/ESPE e All Bond 2 - Bisco. Para a realização do teste foram utilizados quarenta dentes molares hígidos, sendo que destes dentes dez foram utilizados para a microscopia eletrônica de varredura. Para a realização do teste de microtração os dentes foram cortados na superfície oclusal com disco diamantado e posteriormente foram desgastados com discos de lixa. Posteriormente as amostras foram restauradas com os respectivos sistemas adesivos e resina composta Z-100 com tempo de polimerização de 40 segundos cada incremento. Após vinte e quatro horas de armazenagem em temperatura de 37ºC os dentes foram seccionados com disco diamantado com finalidade de obter palitos com área de 1,0 +- 0,2 mm2. Após o corte os palitos foram armazenados em temperatura de 37ºC por vinte e quatro horas e em seguida foram levados para a máquina de ensaio universal EMIC 500 DL onde os palitos foram tracionados com velocidade de 1 mm/min. Os resultados foram analisados pelo através dos testes de normalidade de Lilliefors e de homogeneidade de variância de Bartlett. Quando alguns dos pressupostos não se verificaram, utilizou-se o teste não paramétrico de Kruskal - Wallis. Os resultados obtidos foram em ordem decrescente de 36,73 +- 10,52 para o sistema adesivo One Up Bond F, seguido do sistema de três etapas All Bond 2 com 34,29 +- 12,63 para o sistema adesivo One Step Plus foi de 33,18 +- 11,33 para o sistema Adper Prompt L-Pop de 31,76 +- 11,3, sistema One Step de 29,02 +- 11,28, para o... (Resumo completo, clicar acesso eletrônico abaixo).
Abstract: The aim of this study was to analyze the bond strength of ten adhesive systems: One Up Bond F - Tokuyama (OU); Adper Prompt L-Pop - 3M-ESPE (AP); Clearfil SE Bond - Kuraray CO. (SE); Prime Bond NT - Caulk-Dentsply (NT); Single Bond - 3M-ESPE (SB); One Step - Bisco (OS); One Step Plus - Bisco (OP); Excite - Vivadent (EX); Scotchbond Multi - Purpose (SMP) e All Bond 2 - Bisco (AB). Methods: Forty freshly extracted human teeth were transversely wetcut using a diamond disk in order to expose the occlusal dentin surface. Then the adhesive systems were applied according to the manufacturer's instruction. The teeth were restored with composite resin Z-100 (3M) and stored in distilled water at 37ºC for 24 hours. A slow-speed diamond disk was used to prepare microtensile test specimens, with a bonded area of 1,00 +- 0,2 mm2. Each group was composed of thirty sticks, which were stored in distilled water at 37ºC for 24 hours. The sticks were bonded on a universal testing machine at a cross head speed of 1 mm/min. The following results demonstrate values microtensile bond strengths in MPa. Data were statistically analyzed by Kruskal-Wallis Test (p<-0.05). The bond strength values were 36,73 +- 10,52 for One Up Bond F, 34,29 +- 12,63 for All Bond 2, 33,18 +- 11,33 for One Step Plus, 31,76 +- 11,3 for Adper Prompt L-Pop, 29,02 +- 11,28 for One Step, 28,82 +- 14,74 for Single Bond, 28,08 +- 12,09 for Clearfil SE Bond, 26,31 +- 9,02 for Scotchbond Multi - Purpose, 21,35 +- 10,22 for Prime&Bond NT and 19,52 +- 10,08 for Excite. Ten teeth were analysed by SEM and all of them showed resin into the dentin tubules. Most of fractures were adhesive in the composite/teeth interface. One up bond F (OU) resulted in higher bond strength when compared to all the other systems tested and Excite resulted in lower bond strength. Self-etching systems were not statistically... (Complete abstract, click electronic address below).
Doutor
APA, Harvard, Vancouver, ISO, and other styles
27

Legramandi, Debora Barrozo. "Resistência adesiva à dentina após clareamento dental." Universidade de São Paulo, 2005. http://www.teses.usp.br/teses/disponiveis/25/25131/tde-30092005-094942/.

Full text
Abstract:
Com a introdução de várias técnicas de clareamento dental, bem como o lançamento de vários agentes clareadores em diferentes concentrações e formas de ativação (química e física), se faz necessária a investigação de sua ação sobre as estruturas dentais. Assim, o objetivo desse estudo foi testar as hipóteses de que a técnica de clareamento dental com peróxido de hidrogênio a 35% (Whiteness HP) diminui a resistência adesiva à dentina dos sistemas adesivos convencionais contendo como solvente acetona (Prime & Bond NT) ou água e etanol (Single Bond) e do sistema adesivo autocondicionante (Clearfil SE Bond) e que após sete dias do clareamento os valores de resistência adesiva à dentina humana retornam aos valores dos dentes não submetidos a clareamento. Foram confeccionados 162 espécimes, divididos em 9 grupos: GRUPO 1- (controle) - sistema adesivo convencional Prime & Bond NT. GRUPO 2- (controle) - sistema adesivo convencional Single Bond; GRUPO 3- (controle) - sistema adesivo autocondicionante Clearfil SE Bond; GRUPO 4 - clareamento com Whiteness HP e adesão imediata com sistema adesivo convencional Prime & Bond NT; GRUPO 5 - clareamento com Whiteness HP e adesão imediata com sistema adesivo convencional Single Bond; GRUPO 6 - clareamento com Whiteness HP e adesão imediata com sistema adesivo autocondicionante Clearfil SE Bond; GRUPO 7 - clareamento com Whiteness HP; armazenamento em estufa a 37°C durante 7 dias e sistema adesivo Prime & Bond NT GRUPO 8 - clareamento dental com Whiteness HP; armazenamento em estufa a 37% durante 7 dias e sistema adesivo convencional Single Bond; GRUPO 9 - clareamento com Whiteness HP; armazenamento em estufa a 37% durante 7 dias e sistema adesivo autocondicionante Clearfil SE Bond. Todos os dentes foram restaurados com resina composta TPH e submetidos ao teste de microtração à velocidade de 1.0 mm/min em uma máquina de ensaios universal (Emic, Brasil). As médias e respectivos desvios - padrão para cada grupo foram: G1-25.73 ±3.84; G2- 24.26 ±3.78; G3- 30.95 ±5.02; G4- 23.81 ±6.68; G5- 23.60 ±5.88; G6-28.85 ±3.81; G7- 32.69 ± 8.06; G8- 25.86 ±6.16; G9- 27.45 ±8.97. Após análise estatística pelos testes ANOVA a um critério e Tukey , para comparações individuais, foi possível concluir que a técnica de clareamento dental com o peróxido de hidrogênio a 35% promoveu uma diminuição da resistência adesiva à dentina do sistema adesivo que apresenta acetona como solvente (Prime & Bond NT), sendo que os valores de resistência adesiva foram recuperados sete dias após o clareamento dental; a técnica de clareamento dental com o peróxido de hidrogênio a 35% não alterou a resistência adesiva à dentina do sistema adesivo que apresenta água e etanol como solvente (Single Bond) e para o sistema adesivo autocondicionante (Clearfil SE Bond).
The aim of this study was to evaluate the effect of a bleaching agent and the influence of delaying the bonding procedures on bond strength to human dentin using different adhesive systems. The first hypothesis to test was that the bleaching technique with 35% hydrogen peroxide (Whiteness HP) decreases the bond strength to dentin when two conventional adhesive systems (an acetone-based - Prime&Bond NT (PB); a water/ ethanol based - Single Bond (SB)) and a self- etching system (Clearfil SE Bond (SE) are applied. The second hypothesis was that there is no difference in bond strength values 7 days after bleaching. Thirty six specimens were prepared and divided into 9 groups: G1- PB (control), G2- SB (control); G3- SE (control), G4- Whiteness HP (HP) + immediate bonding procedure with PB, G5- HP + immediate bonding with SB, G6- HP + immediate bonding with SE, G7- HP + storage at 37oC for 7 days + PB, G8- HP + storage at 37o C for 7 days + SB, G9- HP + storage at 37oC for 7 days + SE. After bonding agent application, all teeth were restored with resin composite TPH and submitted to microtensile test in a Universal Testing Machine (Emic, Brazil) at a crosshead speed of 1mm/ min. Data were analyzed by ANOVA and Tukey tests (5%). The mean values (MPa) and standard deviation for each group was: G1- 25.73 ± 3.84; G2- 24.26 ± 3.78, G3- 30.95 ± 5.02, G4-23.81 ± 6.68, G5- 23.60 ± 5.88, G6- 28.85 ± 3.81, G7- 32.69 ± 8.06, G8- 25.86 ± 6.16, G9- 27.45 ± 8.97. It can be concluded that the bleaching technique using 35% hydrogen peroxide decreased the bond strength to dentin when acetonebased system (PB) was applied. However, the bond strength mean values were reversed 7 days after bleaching. There was no influence of 35% hydrogen peroxide bleaching treatment on bond strength when SB (water/ ethanol based) and SE (self- etching) were used.
APA, Harvard, Vancouver, ISO, and other styles
28

Gonçalves, Sérgio Eduardo de Paiva. "Adesivos multi-uso-avaliação da resistência adesiva a dentina frente a teste de cisalhamento, estereomicroscopia e microscopia eletrônica de varredura /." São Jose dos Campos, 1994. http://hdl.handle.net/11449/131859.

Full text
Abstract:
Orientador: Maria Amélia Máximo de Araújo
Banca: Dan Mihail Fichman
Banca: Rogerio Lacaz Neto
Resumo: Adesão tem sido a meta das pesquisas Odontológicas nas últimas décadas. Para determinar se os mais recentes sistemas adesivos denominados como MULTI-USO poderiam ser utilizados associados a diferentes marcas comerciais de resina composta, em dentina, foram realizados testes de resistência ao cisalhamento. Setenta e dois corpos de prova foram confeccionados utilizando-se dentes pré-molares humanos íntegros, embutidos em resina acrílica, expondo-se a dentina por tratamento com lixas d'água de granulações 180, 400 e 600. Os corpos de prova foram divididos em três grupos: Grupo 1 Scotchbond Multi-Purpose (3M), grupo 2 - Optibond Light Cure (Kerr) e grupo 3 - Optibond Dual Cure (Kerr). Todos os grupos foram subdivididos em sub-grupos de 8 dentes, nos quais foram inseridas as resinas compostas: a-Z1 00 (3M do Brasil), bPrisma APH (Dentsply) e c- Herculite XRV(Kerr). Os corpos de prova foram submetidos à ciclagem térmica e após 24 horas de armazenamento em água destilada 370C, aos testes de resistência ao cisalhamento em máquina lnstron 4301 seguidos de análise em estereomicroscópio Technivai-Carl Zeiss de aumento para avaliar o tipo de fratura e, análise em microscopia eletrônica de varredura (M.E.V.). A aplicação do modelo estatístico de análise de variância permitiu a constatação de que o fator Adesivo apresentou um valor significante (p<0,05) independente do fator Resina, tendo o adesivo Optibond Light Cure propiciado a maior resistência média ao cisalhamento (15,446 MPa), seguido do Scotchbond Multi-Purpose (13,340 MPa) e do Optibond Dual Cure (1 0,019 MPa). A interaçâo Adesivo x Resina apresentou um valor estatisticamente significante (p<0,05), onde os melhores resultados foram obtidos entre as resinas Z100 e Herculite XRV com o adesivo Optibond Light Cure, e entre a Resina APH com o adesivo Scotchbond Multi-Purpose. Concluímos que o adesivo Optibond...
Abstract: Recent bonding systems have been advocated as "multi-purpose bonding agents". The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose
Mestre
APA, Harvard, Vancouver, ISO, and other styles
29

Galafassi, Daniel. "Avaliação in vitro da microtração de sistemas adesivos à dentina irrigada com soluções endodônticas: Influência da degradação da interface adesiva." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/58/58133/tde-20022009-085707/.

Full text
Abstract:
O objetivo desse trabalho foi avaliar a influência da resistência de união de sistemas adesivos à dentina irrigada com substâncias endondônticas, após a degradação da interface adesiva e análise morfológica da interface adesiva por meio de microscopia eletrônica de varredura (MEV). Foram selecionados sessenta terceiros molares, que tiveram a porção oclusal removida e planificada expondo a dentina profunda. Os espécimes foram irrigados com hipoclorito de sódio a 2,5% por 30 minutos e em seguida em EDTA 17% por 5 minutos. Após a irrigação da superfície detinária os dentes foram divididos aleatoriamente em seis grupos (n = 10) de acordo com o sistema adesivo empregado: G1 e G2 - Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). Após a aplicação do sistema adesivo, foi confeccionado um platô de resina composta Z100 (3M). A degradação da interface adesiva foi realizada por meio de estocagem em água deionizada/ciclagem térmica: 24 horas de estocagem em água deionizada/nenhum ciclo (grupos G1, G3 e G5) e 6 meses de estocagem em água deionizada/12.000 ciclos (grupos G2, G4 e G6). Após os períodos pré-estabelecidos em cada grupo, os conjuntos dente/resina foram seccionados de forma a se obter 4 palitos de aproximadamente de 1mm2, que foram submetidos ao teste de microtração. A análise morfológica da interface foi realizada por meio de MEV. Os dados obtidos foram submetidos a ANOVA e teste de Tukey ao nível de 5%. Verificou-se que houve diferença significativa entre os adesivos (p<0,01). A durabilidade da adesão da resina composta a dentina irrigada com solução endodôntica não foi afetada após 6 meses de estocagem em água e 12.000 ciclos térmicos (p<0,05). A análise da interface adesiva evidenciou que os sistemas adesivos não alteraram o padrão de união mesmo após 6 meses de ciclagem térmica e degradação em água, exceto para o sistema adesivo XP Bond. Pode-se concluir que a dentina irrigada com NaOCl e EDTA apresentou menor resistência a microtração quando do emprego do sistema adesivo XP Bond. A degradação da interface por meio do armazenamento em água e ciclagem térmica não influenciou na resistência de união, independente do sistema adesivo empregado.
The aim of the present study was to survey the influence of endodontic irrigants on the adhesion resistance of adhesive systems to human dentin, after the degradation of adhesive interface and morphologic analysis of adhesive interface for Scanning Electronic Microscopy SEM. Sixty molar thirds were selected. The deep dentin was exposed removing and ground the oclusal portion. The specimens were irrigated with sodium hypochlorite 2,5% for 30 minutes followed by EDTA 17% for 5 minutes. Subsequently, teeth were divided randomly in six groups (n=10) accordingly to adhesive system applied: G1 and G2 Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). After adhesive system application, a composite resin Z100 (3M) was built up created. The degradation of the adhesive interface was realized by storage the specimens in deionized water and thermocycling: 24 hours of deionized water storage/no cycle (groups G1, G3 and G5) and 6 months storage in deionized water/12.000 cycles (groups G2, G4 and G6). After pre-established periods of each group, the systems tooth/resin were sectioned in order to obtain 4 sticks of approximately 1mm2, which were subjected to microtensile bond strength test. The morphologic analysis of interface was performed for SEM. Results were analyzed with ANOVA and Tukey test to level 5%. Significant difference between adhesives was verified (p<0,01). The water storage (6 months) coupled with thermocycling (12.000 cycles) did not affected significantly the resistance to microtensile bond strength of the dentin (p<0,05). The conclusion is that dentin irrigated with NaOCl and EDTA presented less resistance to microtensile bond strength when XP Bond Adhesive system was utilized. The interface degradation through water storage and thermocycling had no effect on the resistance of the dentin bond, independently of the adhesive system applied.
APA, Harvard, Vancouver, ISO, and other styles
30

Reyes, Mario Felipe Gutiérrez. "EFEITO DA INCORPORAÇÃO DE NANOPARTÍCULAS DE COBRE EM UM SISTEMA ADESIVO CONVENCIONAL NAS PROPRIEDADES MICROBIOLÓGICAS, MECÂNICAS E ADESIVAS À DENTINA." UNIVERSIDADE ESTADUAL DE PONTA GROSSA, 2016. http://tede2.uepg.br/jspui/handle/prefix/1728.

Full text
Abstract:
Made available in DSpace on 2017-07-24T19:22:05Z (GMT). No. of bitstreams: 1 FELIPE GUTIERREZ REYES.pdf: 2973646 bytes, checksum: 0e8c702449c97c861e9f0314e3b69e2f (MD5) Previous issue date: 2016-02-23
Objectives: This study evaluated the effect of addition of copper nanoparticles at different concentrations into a simplified etch-and-rinse (ER) adhesive system (Ambar [AM]) on antimicrobial activity (AMA), degree of conversion of adhesives discs (DC-d) and dentin-resin interface (DC-i), the ultimate tensile strength (UTS), 28-day cumulative water sorption (WS), solubility (So) and copper release (CR) as well as immediate (IM) and 1-year (1Y) resin–dentine bond strength (μTBS) and nanoleakage (NL). Methods: Seven experimental adhesive systems were formulated according to the addition of copper nanoparticles (0 [control], 0.0075, 0.015, 0.06, 0.1, 0.5 and 1%) in AM adhesive system. We tested the antimicrobial activity of synthesized adhesives against Streptococcus mutans using agar diffusion assays. For DC-d, specimens were constructed and tested after 24 h for FTIR and micro-Raman spectroscopy. For UTS, specimens were tested after 24 h and 28 days. For WS and So, after specimens build-up, they were stored in water and the properties measured for 28 days. For CR, specimens were stored in 2% nitric acid solution and the properties were measured for 28 days. The occlusal enamel of thirty-five molars was removed and adhesives were applied to dentine surface after 37% phosphoric acid etching. After composite resin build-ups, specimens were longitudinally sectioned to obtain resin–dentine bonded sticks (0.8 mm2). Specimens were tested in tension at 0.5 mm/min in IM or 1Y (μTBS). For NL, 2 bonded sticks from each tooth were prepared and analyzed under SEM in IM or 1Y. For DC-i, 2 bonded sticks were prepared and analyzed under micro-Raman spectroscopy. The μTBS and NL data of each adhesive were subjected to two-way repeated measures ANOVA. For UTS, WS, So, copper release, DC-d and DC-i data of each adhesive were subjected to a one-way ANOVA. Tukey’s post hoc test was used for pair-wise comparisons (α = 0.05). Results: The addition of copper nanoparticles provided antimicrobial properties to the adhesives at all concentrations (p < 0,05), and did not influence UTS, WS and SO (p > 0.05). Higher CR was observed in adhesives with higher concentration of copper nanoparticles (p < 0.05). The addition of 1% of copper nanoparticles decreased the DC-d and DC-i significantly. After 1Y, significant reductions of μTBS and increases of NL were observed in the control group (p < 0.05). Reductions of μTBS and increase of NL over time were not observed for copper-containing adhesives.Conclusions: The addition of copper nanoparticles in concentrations up to 0.5% in the simplified ER Ambar adhesive system may be an alternative to provide antimicrobial properties, increase the long-term stability of resin–dentine interfaces, 12 without reducing adhesives’ mechanical properties evaluated.
Objetivos: Este estudo avaliou o efeito da adição de nanopartículas de cobre, em diferentes concentrações, em um sistema adesivo convencional (CON) simplificado Ambar [FGM] sobre a atividade antimicrobiana (AAM), grau de conversão de corpos de prova de adesivos (GC-c) e na interface de união a dentina (GC-i), resistência máxima à tração (RT), sorção cumulativa de água (SO), solubilidade (SB) e liberação de cobre (LC) durante 28 dias, bem como a resistência de união (RU) e nanoinfiltração (NI) na interface de união à dentina nos tempos imediatos (IM) e após 1 ano (1A). Material e métodos: Sete sistemas adesivos experimentais foram formulados de acordo com a adição de nanopartículas de cobre (0 [controle], 0,0075, 0,015, 0,06, 0,1, 0,5 e 1%) no sistema adesivo Ambar. Foi testada a atividade antimicrobiana dos adesivos formulados contra Streptococcus mutans por meio de ensaios de difusão em ágar. Para GC-c, as amostras foram construídas e testadas após 24 h por meio de espectrofotometria no infravermelho com Transformação de Fourier (FTIR) e espectroscopia de micro-Raman. Para RT, as amostras foram testadas depois de 24 horas e 28 dias. Para SO e SB, depois de confeccionados os espécimes, eles foram armazenados em água e as propriedades medidas por 28 dias. Para LC, as amostras foram armazenadas em solução de ácido nítrico a 2% e as propriedades medidas durante 28 dias. O esmalte oclusal de trinta e cinco molares foi removido e os adesivos foram aplicados na superfície da dentina depois de condicionamento com ácido fosfórico a 37%. Depois de restaurações de resina composta, os espécimes foram seccionados longitudinalmente para se obter espécimes (palitos) de resina-dentina (0,8 mm2). Os espécimes foram testados em tensão a 0,5 mm/min no IM ou 1A (RU). Para NI, 2 espécimes de cada dente foram preparadas e analisadas em MEV e testados no IM ou 1A. Para GC-i, 2 espécimes foram preparados e analisados sob espectroscopia de micro-Raman. Os dados do RT foram analisados por uma análise de variância de 2 fatores. Para AAM, SO, SB, e liberação de cobre, os dados foram analisados por análise de variância de fator único, e para RU e NI os dados foram submetidos a análise de variância de 2 fatores para medidas repetidas. Também foi feito o teste post hoc de Tukey para múltiplas comparações. A significância estatística foi predefinida em α = 0,05.Resultados: A adição de nanopartículas de cobre adicionou propriedades antimicrobianas aos adesivos em todas as concentrações (p < 0,05), e não influenciou a RT, SO e SB (p > 0,05). LC elevadas foram observadas em adesivos com maior concentração de nanopartículas de cobre (p < 0,05). A adição de 1% de 10 nanopartículas de cobre diminuiu significativamente o GC-c e GC-i. Após 1 ano, decréscimos significativos de RU e aumentos de NI foram observados no grupo controle (p < 0,05). Decréscimos significativos de RU e aumentos de NI não foram observados nos adesivos contendo cobre (p > 0,05). Conclusões: A adição de nanopartículas de cobre em concentrações de até 0,5% no sistema adesivo convencional simplificado Ambar pode ser uma alternativa para adicionar atividade antimicrobiana e aumentar a estabilidade a longo prazo das interfaces resina-dentina, sem comprometer as propriedades mecânicas dos adesivos.
APA, Harvard, Vancouver, ISO, and other styles
31

Gonçalves, Sérgio Eduardo de Paiva [UNESP]. "Adesivos multi-uso-avaliação da resistência adesiva a dentina frente a teste de cisalhamento, estereomicroscopia e microscopia eletrônica de varredura." Universidade Estadual Paulista (UNESP), 1994. http://hdl.handle.net/11449/131859.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:22:16Z (GMT). No. of bitstreams: 0 Previous issue date: 1994-12-15. Added 1 bitstream(s) on 2015-12-10T14:28:20Z : No. of bitstreams: 1 000023950.pdf: 5255881 bytes, checksum: a5b00e9d9a2096ed77f9f420143ca8d6 (MD5)
Adesão tem sido a meta das pesquisas Odontológicas nas últimas décadas. Para determinar se os mais recentes sistemas adesivos denominados como MULTI-USO poderiam ser utilizados associados a diferentes marcas comerciais de resina composta, em dentina, foram realizados testes de resistência ao cisalhamento. Setenta e dois corpos de prova foram confeccionados utilizando-se dentes pré-molares humanos íntegros, embutidos em resina acrílica, expondo-se a dentina por tratamento com lixas d'água de granulações 180, 400 e 600. Os corpos de prova foram divididos em três grupos: Grupo 1 Scotchbond Multi-Purpose (3M), grupo 2 - Optibond Light Cure (Kerr) e grupo 3 - Optibond Dual Cure (Kerr). Todos os grupos foram subdivididos em sub-grupos de 8 dentes, nos quais foram inseridas as resinas compostas: a-Z1 00 (3M do Brasil), bPrisma APH (Dentsply) e c- Herculite XRV(Kerr). Os corpos de prova foram submetidos à ciclagem térmica e após 24 horas de armazenamento em água destilada 370C, aos testes de resistência ao cisalhamento em máquina lnstron 4301 seguidos de análise em estereomicroscópio Technivai-Carl Zeiss de aumento para avaliar o tipo de fratura e, análise em microscopia eletrônica de varredura (M.E.V.). A aplicação do modelo estatístico de análise de variância permitiu a constatação de que o fator Adesivo apresentou um valor significante (p<0,05) independente do fator Resina, tendo o adesivo Optibond Light Cure propiciado a maior resistência média ao cisalhamento (15,446 MPa), seguido do Scotchbond Multi-Purpose (13,340 MPa) e do Optibond Dual Cure (1 0,019 MPa). A interaçâo Adesivo x Resina apresentou um valor estatisticamente significante (p<0,05), onde os melhores resultados foram obtidos entre as resinas Z100 e Herculite XRV com o adesivo Optibond Light Cure, e entre a Resina APH com o adesivo Scotchbond Multi-Purpose. Concluímos que o adesivo Optibond...
Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose
APA, Harvard, Vancouver, ISO, and other styles
32

Leite, Murillo Martins. "Resistência de união entre cimento resinoso auto-adesivo e dentina selada com adesivo auto condicionante." Universidade Federal de Goiás, 2017. http://repositorio.bc.ufg.br/tede/handle/tede/6929.

Full text
Abstract:
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2017-03-09T17:27:02Z No. of bitstreams: 2 Dissertação - Murillo Martins Leite - 2017.pdf: 2935464 bytes, checksum: c2e541fcfb0b7d14e4119dc3da509cac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-03-10T10:54:28Z (GMT) No. of bitstreams: 2 Dissertação - Murillo Martins Leite - 2017.pdf: 2935464 bytes, checksum: c2e541fcfb0b7d14e4119dc3da509cac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Made available in DSpace on 2017-03-10T10:54:28Z (GMT). No. of bitstreams: 2 Dissertação - Murillo Martins Leite - 2017.pdf: 2935464 bytes, checksum: c2e541fcfb0b7d14e4119dc3da509cac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-23
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq
The daily practice of dentists evolves when restorative techniques lead to higher success rates and long-lasting in treatments associated to less invasive procedures. In this context, self-etching adhesives, self-adhesive cements and immediate dentin sealing are examples of modern materials and technique with an uprising popularity among clinicians. The objective of this study was to evaluate the influence of different surface treatment on the sealed dentin with self-etching adhesive on bond strength to a self-adhesive resin. The coronary portions of 90 bovine teeth, included in epoxy resin, were worn out for dentin exposure. The sample was randomly subdivided in six groups. In group C (control) the dentin was kept "fresh" while immediate dentin sealing with Clearfil SE Bond (Kuraray) were performed in the others five groups. After 24 hours of storage, the sealed dentin of the samples received different surface treatments: P group (prophylaxis with pumice); PA group (prophylaxis followed by etching with phosphoric acid); PAS group (prophylaxis, phosphoric acid and silanization); PASC group (prophylaxis, phosphoric acid, silanization and bonding layer of adhesive Clearfil SE Bond) and PAU group [prophylaxis, phosphoric acid and a universal adhesive layer Single Bond Universal (3M ESPE)]. After these protocols, U200 self-adhesive cement (3M ESPE) cylinders were bonded in all six groups, forming an average of 15 sample units per group. The samples were submitted to microshear bond strength test at 0.5mm/min for two storage times: 24 hours (T1) e 3 months (T2). Statistical analysis was carried out using Kruskal-Wallis test, presenting a significant difference between RUM values (p=0.0018) among groups, for 24 hours of storage, and PASC group presented values significantly higher than all other groups. For 3 months of storage, there was no significant difference (p=0,223) between the groups. It is possible to conclude that immediate dentin sealing produced microshear bond strength values similar to control group (as recommended by manufacturer, without immediate sealing), except for the group that associated prophylaxis, phosphoric acid, silane and Clearfil SE Bond that was significantly higher in 24 hours tests, without significant changes with 3 months of storage.
A odontologia evolui a partir de tratamentos que ofereçam alto índice de sucesso em comunhão com simplicidade técnica e menor agressão biológica possível. Nesse contexto, adesivos auto condicionantes, cimentos auto-adesivos e o selamento imediato da dentina são exemplos de materiais e técnica que estão sendo atualmente difundidos. O objetivo deste trabalho foi avaliar a influência de diferentes tratamentos de superfície para a dentina selada, com adesivo auto condicionante, na resistência de união com cimento resinoso auto-adesivo. As porções coronárias de 90 dentes bovinos, incluídas em cilindros de resina epóxi, foram desgastadas superficialmente até a exposição da dentina. A amostra foi subdividida em seis grupos aleatoriamente. No grupo C (controle) a dentina foi mantida “fresca” enquanto que nos outros cinco grupos foi realizado o selamento imediato da dentina com Clearfil SE Bond (Kuraray). Após armazenamento por 24 horas, receberam diferentes tratamentos da superfície selada: Grupo P (profilaxia com pedra pomes); Grupo PA (profilaxia seguido da aplicação do ácido fosfórico); Grupo PAS (profilaxia, ácido fosfórico e silano); Grupo PASC (profilaxia, ácido fosfórico, silano e adesivo do Clearfil SE Bond) e grupo PAU [profilaxia, ácido fosfórico e Single Bond Universal (3M ESPE)]. Após a realização desses protocolos, foram unidos, em todos os seis grupos, cilindros do cimento auto-adesivo U200 (3M ESPE), formando uma média de 15 unidades amostrais por grupo, sendo assim submetidos ao teste de resistência de união ao microcisalhamento (RUM) à 0,5mm/min para dois tempos de armazenamento: 24 horas (T1) e 3 meses (T2). De acordo com o teste Kruskal-Wallis, para o tempo de 24 horas de armazenamento, houve diferença significante entre os valores de RUM (p=0,0018) para os diferentes protocolos com o grupo PASC apresentando valores significativamente maiores que os demais grupos. Já em relação ao tempo de 3 meses de armazenamento, não houve diferença significante (p=0,223) entre os grupos. É possível concluir que o selamento imediato da dentina produziu valores de resistência de união semelhantes ao grupo controle (sem selamento imediato), recomendado pelo fabricante, exceto para o grupo que associou profilaxia, ácido fosfórico, silano e Clearfil SE Bond que foi significativamente superior nos testes com 24 horas, porém não havendo alterações significativas com 3 meses de armazenamento.
APA, Harvard, Vancouver, ISO, and other styles
33

Almeida, Julio Cesar Franco. "Durabilidade da união resina-dentina : efeito da umidade dentinaria na resistencia da união mediada por primers experimentais." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288202.

Full text
Abstract:
Orientadores: Mario Fernando de Goes, Marcela Rocha de Oliveira Carrilho
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-13T06:17:38Z (GMT). No. of bitstreams: 1 Almeida_JulioCesarFranco_D.pdf: 499079 bytes, checksum: 777476c1e47008d96a6038604656dce4 (MD5) Previous issue date: 2009
Resumo: O objetivo geral deste estudo foi avaliar in vitro os efeitos de variações na umidade dentinária no estabelecimento e durabilidade da união resina-dentina através da associação de materiais e técnicas que apresentam potencial para uso em restaurações adesivas. Para atender ao objetivo geral, dois estudos com objetivos específicos foram propostos: 1) avaliar os efeitos da condição de umidade da dentina na durabilidade da resistência da união (RU) à dentina obtida por meio da associação de oxalato de potássio com primers a base de água ou etanol. 2) avaliar os efeitos da técnica úmida utilizando etanol na durabilidade da RU à dentina obtida através do uso de primers com características hidrofílicas e hidrofóbicas. Os primers experimentais foram preparados utilizando-se a proporção 35% monômeros / 65% solventes (v/v), como se segue: HEMA/água, HEMA/etanol, Bis-GMA/etanol e um agente de união com características hidrofóbicas (Adper Scothbond Multi-Purpose adhesive, 3M/ESPE) foi usado nos dois estudos. A RU foi avaliada pelo teste de resistência à microtração 24 h após a realização do procedimento adesivo ou após 6 meses de armazenamento em água, utilizando-se dentes humanos hígidos recém extraídos para confecção das amostras de acordo com os objetivos específicos de cada estudo. Os resultados do estudo 1 mostraram que de uma maneira geral a associação de oxalato de potássio com primers a base de água e etanol reduziu significativamente a RU imediata e a longo prazo para os primers a base de água e etanol, independente da condição de umidade da dentina. Os resultados do estudo 2 indicaram que a técnica úmida com etanol resultou em maior RU imediata para os primers com características hidrofílicas e hidrofóbicas enquanto o armazenamento em água por 6 meses diminuiu a RU para o primer hidrofílico, independente da técnica utilizada.
Abstract: The overall goal of this investigation was to evaluate in vitro the effects of dentin moisture variations in the establishment and durability of the resin-dentin bonds by the association of materials and techniques with potential for use in adhesive restorative procedures. In order to meet the overall objective, two studies with specific goals were proposed. 1) to evaluate the effects of dentin moisture condition on the durability of the bond strength (BS) to dentin produced by the association of potassium oxalate with experimental water-and ethanolbased primers; 2) to evaluate the effects of the ethanol wet-bonding technique on the durability of the BS produced with the use of experimental primers with hydrophilic and hydrophobic characteristics. The experimental primers were prepared using the proportion 35% monomers / 65% solvents (v/v) as follows: HEMA/water, HEMA/ethanol, Bis-GMA/ethanol and the same bonding agent with hydrophobic characteristics was used in both studies (Adper Scothbond Multi- Purpose adhesive, 3M/ESPE). A microtensile bond strength test was performed 24 h after bonding procedures and 6 months after water storage, using freshly extracted noncarious human teeth for specimen preparation according to the specific goals of each study. In general, the results of study 1 showed that the association of potassium oxalate with water-and ethanol-based primers reduced significantly the immediate and long-term BS, regardless of the dentin moisture condition. The results of study 2 showed that the ethanol wet-bonding technique resulted in higher immediate BS for the hydrophilic and hydrophobic primers, while 6-month water storage reduced the BS for the hydrophilic primer, regardless of the employed bonding technique.
Doutorado
Doutor em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
34

Miranda, Carla. "Avaliação de sistemas adesivos em dentina decídua." Florianópolis, SC, 2009. http://repositorio.ufsc.br/xmlui/handle/123456789/92540.

Full text
Abstract:
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia.
Made available in DSpace on 2012-10-24T09:54:18Z (GMT). No. of bitstreams: 1 265559.pdf: 9972981 bytes, checksum: 21d2a7f51e034815708f9f2861c652d5 (MD5)
Este estudo in vitro foi realizado com o objetivo de avaliar a resistência à microtração, e a nanoinfiltração de sistemas adesivos em dentina decídua, imediatamente (IM) e após seis meses (6M) do procedimento adesivo. Coroas de molares decíduos, hígidos e extraídos, foram desgastadas com papel de carbeto de silício até a granulação 600, obtendo-se superfícies oclusais planas, distribuídas em quatro grupos: Scotchbond Multi-Purpose (SMP), Single Bond (SB), Clearfil SE Bond (CSB) e Adper Prompt L-Pop (APL). Baseado nos dados obtidos pôde-se concluir que a resistência adesiva e a nanoinfiltração não foram influenciadas pelo envelhecimento e que a expressão da nanoinfiltração foi diferente entre os adesivos de condicionamento ácido total e autocondicionantes.
APA, Harvard, Vancouver, ISO, and other styles
35

Sousa, Ana Beatriz Silva. "Efeito do uso de primers bioativos na interface dentina-adesivo." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/58/58131/tde-10082015-102247/.

Full text
Abstract:
A longevidade das restaurações com compósitos está diretamente relacionada ao sucesso do tratamento estético. A vida útil das restaurações pode ser influenciada por vários fatores como o material empregado, tempo de uso clínico e a degradação da matriz dentinária por metaloproteinases da matriz (MMPs), que podem afetar a integridade da interface adesiva, fazendo com que a união dentina-­adesivo seja comprometida. Assim, buscando melhores resultados na durabilidade das restaurações adesivas, o objetivo deste estudo foi avaliar o efeito de substâncias inibidoras de MMPs (soluções de clorexidina -­ CHX a 0,2% e doxiciclina a 3%) e agente de ligação cruzada (extrato de semente de uva -­ grape seed extract - GSE a 15%) na Resistência de União (RU) de restaurações de resina composta submetidas à ciclagem mecânica. Cavidades de Classe I foram preparadas na área central da superfície exposta de 48 molares humanos hígidos, posteriormente separados em 4 grupos (n=12) de acordo com o tratamento de superfície recebido após o condicionamento de ácido: Grupo I -­ Controle (Sistema Adesivo -­ Adper Single Bond Plus -­ 3M ESPE); Grupo II -­ CHX 0,2% + Sistema Adesivo; Grupo III -­ GSE 15% + Sistema Adesivo e Grupo IV -­ Doxiciclina 3% + Sistema Adesivo. Após os procedimentos restauradores (Filtek Supreme Ultra -­ 3M ESPE), as amostras foram armazenadas em água destilada durante 24 horas a 37°C e subdividas em dois subgrupos: A -­ Controle (armazenado em saliva artificial) e B -­ Submetido à ciclagem mecânica (Coil Cycler, Proto-­tech, forca de 50 N, frequência de 1,5 Hz em 1 x 106 ciclos de aplicação). Após ciclagem mecânica, os corpos de prova foram cortados em palitos (0,8 x 0,8 mm; n = 5 por dente) e submetidos ao teste de microtração (Bisco) a velocidade de 1 mm/min. A atividade colagenolítica da MMP-­2 sob a ação dos primers bioativos foi analisada utilizando o kit EnzChek Gelatinase/Colagenase Assay (D-­12054, Molecular Probes, Eugene, OR, EUA). A atividade gelatinolítica das MMPs-­2 e -­9 após incubação com os primers bioativos foi avaliada através de zimografia convencional. Os resultados obtidos das duas análises foram apresentados na forma de porcentagem de inibição. Zimografia in situ foi realizada utilizando gelatina de fluorescência conjugada (Kit EnzChek Gelatinase/Collagenase Assay) como substrato de MMPs e avaliada com aumento de 40x através de microscopia de fluorescência. Posteriormente, os fótons fluorescentes foram analisados em software (ImageJ). Obtidos os resultados, os dados foram submetidos à análise estatística (2way ANOVA, Tukey, p>0,05) e demonstraram que os primers bioativos não exerceram influência significante sobre a RU dentina-­adesivo, independente da ação da ciclagem mecânica. A atividade colagenolítica, segundo zimografia convencional, demonstrou que os primers bioativos foram capazes de inibir as MMPs, sendo a CHX menos eficiente. Na análise de zimografia in situ, os primers bioativos diminuíram a atividade das MMPs localizadas na interface adesiva, com aumento da atividade gelatinolítica do grupo Controle sendo maior quando submetidos à ciclagem mecânica, efeito não encontrados no grupos tratados com primers bioativos. Concluiu-­se que, apesar de não apresentarem efeitos sobre a RU da interface adesiva, os primers bioativos apresentam ação sobre a degradação da camada híbrida.
The durability of composite resin restorations is one of the main points related to the success in aesthetic treatments. The longevity of adhesive restorations can be affected by various factors such as the materials, the clinical time of use and the dentin matrix degradation mediated by matrix metalloproteinases (MMPs). MMPs can affect the adhesive interface, compromising the bonding between dentin and adhesive. Thus, searching for better results on longevity of adhesive restorations, the aim of this study was to evaluate the effect of MMPs inhibitors (chlorhexidine -­ CHX 0.2% and doxycycline 3% ) and crosslinking agent (grape seed extract -­ GSE 15%) on resin composite bond strength (BS) of restorations submitted to load cycling. Class I cavities were performed in the central area of the exposed surface of 48 sound human molars. Then, it was divided into 4 groups (n=12) according to the surface treatment received after the acid etching: Group I -­ Control (Adhesive System -­ Adper Single Bond Plus -­ 3M ESPE); Group II -­ CHX 0.2% + Adhesive System; Group III -­ Doxycycline 3% + Adhesive System e Group IV -­ GSE 15% + Adhesive System. After restorative procedures (Filtek Supreme Ultra -­ 3M ESPE), the samples were stored in distilled water for 24 hours at 37°C and then subdivided into two subgroups (n=6): A -­ Control (stored in artificial saliva) and B -­ Submitted to load cycling (Coil Cycler, Proto-­tech, 50 N, 1.5 Hz, 1 x 106 cycles). After load cycling, the specimens were cut into sticks (0.8 x 0.8 mm; n = 5 per teeth) and submitted to the microtensile test (Bisco) at 1 mm/min. The collagenolytic activity of MMP-­2 under action of bioactive primers was analyzed using EnzChek Gelatinase/Colagenase Assay Kit (D-­12054, Molecular Probes, Eugene, OR, EUA). The gelatinolytic activity of MMPs-­2 and -­9 after incubation with the bioactive primers was evaluated by gelatin zymography. The results of these two analyzes were presented by percentage of inhibition. In situ zymography was performed using fluorescence conjugated gelatin (EnzChek Gelatinase/Collagenase Assay Kit) as MMP substrate and evaluated using 40x magnification under fluorescence microscopy. Then the fluorescent photons were analyzed with an appropriate software (ImageJ). The results were subjected to statistical analysis (2-­way ANOVA, Tukey, p<0.05) and the bioactive primers showed no significant influence on the dentin-­adhesive BS, regardless the load cycling action. According to gelatin zymography, the collagenolytic activity demonstrated that the bioactive primers were able to inhibit MMPs activity and CHX was less efficient. In situ zymography analysis, showed that the bioactive primers decreased the activity of MMPs located in adhesive interface. The data also demonstrated increased gelatinolytic activity on Control group, being higher when submitted to load cycling, and which effect was not found in the groups treated with bioactive primers. It could be concluded that although the bioactive primers did not influenced the BS of adhesive interface, they demonstrated positive results on hybrid layer degradation.
APA, Harvard, Vancouver, ISO, and other styles
36

Schiroky, Priscila Raquel. "Dentina afetada por cárie : avaliação e desenvolvimento de adesivo experimental." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2016. http://hdl.handle.net/10183/151443.

Full text
Abstract:
A Odontologia minimamente invasiva tornou-se possível em decorrência do atual avanço alcançado na Odontologia adesiva, e a remoção seletiva do tecido cariado passou a ser recomendada para dentes com lesões de cárie profunda. Tal preparo cavitário preserva a dentina afetada por cárie (DAC), camada mais interna da dentina cariada que é remineralizável. Entretanto, esse substrato apresenta propriedades mecânicas inferiores e diversos estudos relatam uma resistência de união reduzida. O objetivo do presente estudo foi revisar sistematicamente a literatura quanto a resistência da união dos sistemas adesivos à DAC quando comparada à dentina hígida (DH), assim como a influência das variáveis metodológicas dos estudos in vitro. Além disso, desenvolver e caracterizar uma resina adesiva com a incorporação de um fosfato de cálcio, assim como avaliar o potencial de induzir deposição mineral em dentes com DAC. As buscas foram realizadas nas bases de dados PubMed, Scopus, Web of Science e LILACS. Foram incluídos estudos laboratoriais que investigaram a resistência de união à microtração imediata e longitudinal de sistemas adesivos À DAC natural ou artificial, utilizando DH como controle. Oito artigos preencheram os critérios de inclusão, e uma metaregressão foi realizada para a associação das variáveis independentes do modelo com o desfecho de resistência de união. O modelo final com 5 variáveis explicou 75,6% da variabilidade entre os grupos. Todas as variáveis independentes apresentaram influência significativa no desfecho, e a DAC resultou em menor resistência de união. Sendo assim, uma resina adesiva com a incorporação de α-fosfato tricálcico (αTCP) foi desenvolvida e caracterizada. Para a formulação das resinas adesivas, 66,66% em peso de BisGMA, 33,33% em peso de HEMA e um sistema fotoiniciador foram misturados. O αTCP foi adicionado a 2% em peso, originando a resina adesiva teste. Uma resina sem adição de carga foi utilizada como controle. As resinas adesivas foram caracterizadas quanto à taxa de polimerização e grau de conversão, e degradação em solvente. Sessenta dentes permanentes extraídos com lesões de cárie profunda foram submetidos à remoção seletiva do tecido cariado e restaurados utilizando uma das duas resinas adesivas. As amostras foram avaliadas por meio de ensaios imediatos e longitudinais (no decorrer de 6 meses, armazenadas em SBF) de resistência de união à microtração, avaliação da deposição mineral por espectroscopia Raman e dureza Knoop. A dureza Knoop inicial da resina adesiva teste foi maior quando comparada à controle, e não houve diferença entre os grupos em relação ao percentual de variação da dureza Knoop após a imersão em solvente. O grupo teste apresentou maior taxa de polimerização e não houve diferença entres os grupos para o grau de conversão. Não houve diferença entre os grupos para a resistência de união imediata e longitudinal, e ambos os grupos mantiveram estável a resistência de união após 6 meses. A análise da interface em relação à deposição mineral mostrou que houve aumento do conteúdo mineral para os dois grupos. Em relação à dureza Knoop, houve um aumento nos valores após 3 meses, entretanto não houve diferença entre os grupos dentro das diferentes profundidades para cada tempo. Conclui-se que não houve diferença entre os grupos em relação à deposição mineral.
The minimally invasive dentistry became possible due to the current advancement in adhesive dentistry, and the selective removal of carious tissue has been recommended for teeth with deep carious lesions. Such cavity preparation preserves the caries-affected dentin (CAD), the inner layer of carious dentin that is remineralizable. However, this substrate presents low mechanical properties and many studies reported reduced bond strength. The objective of this study was to systematically review the literature on the microtensile bond strength (μTBS) of adhesive systems to (CAD) when compared to sound dentin (SD), as well as on the influence of methodological variables of in vitro studies. Also, to develop and characterize an adhesive resin with the incorporation of a calcium phosphate, as well as evaluate the potential to induce mineral deposition in teeth presenting CAD. The electronic databases PubMed, Scopus, ISI Web of Science and LILACS were systematically searched. Were included in vitro studies that assessed the immediate and aged microtensile bond strength of adhesive systems to natural or artificially created CAD in comparison to SD. Eight studies met the inclusion criteria and were included in a linear meta-regression of microtensile bond strength. The fully adjusted model with 5 methodological variables explained 75.6% of the variability among groups. All methodological variables were associated with microtensile bond strength, and bond strength to CAD was lower than to SD. Thus, an adhesive resin with the incorporation of α-tricalcium phosphate (αTCP) was developed and characterized. To formulate the experimental adhesive resins, 66.66 wt% BisGMA, 33.33 wt% HEMA and a photo-initiator system were mixed. The αTCP at 2 wt% was added, yielding the test adhesive resin. An adhesive resin without filler was used as control. The adhesive resins were characterized regarding polymerization kinetics and degree of conversion, and softening in ethanol. Sixty extracted human posterior permanent teeth with deep carious lesions were submitted to selective removal of carious tissue and restored using one of the two adhesive resins. Samples were evaluated by immediate and longitudinal (6 months, storage in SBF) following tests: microtensile bond strength, mineral deposition by Raman spectroscopy and Knoop hardness. The test adhesive resin showed higher initial Knoop hardness than the control one, and there was no difference between the groups for the percentage of variation of Knoop hardness after solvent immersion. The test group showed increased polymerization rate, and there was no difference between groups for degree of conversion. There was no difference between the groups for immediate and longitudinal microtensile bond strength, and the microtensile bond strength of both groups remained stable after the 6 months. The interface analysis regarding mineral deposition showed an increasing in mineral content for both groups. For Knoop hardness, there was an increase after 3 months, however the groups where not significantly different considering depth and time. It could be concluded that there was no difference between control and test adhesive resin for mineral deposition.
APA, Harvard, Vancouver, ISO, and other styles
37

Collares, Fabrício Mezzomo. "Síntese de blendas co-monoméricas radiopacas de aplicação odontológica." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2010. http://hdl.handle.net/10183/107974.

Full text
Abstract:
A radiopacidade dos materiais restauradores deve permitir distinguí-los da estrutura dental. Os adesivos dentinários normalmente, não possuem radiopacidade satisfatória a qual pode ser buscada com o acréscimo de substâncias que apresentem essa característica. Entretanto, esses materiais não devem interferir negativamente nas propriedades do polímero formado. O objetivo deste estudo foi avaliar a influência da adição de substâncias radiopacificantes em uma resina adesiva experimental nas propriedades do polímero. Uma resina adesiva experimental foi formulada com 50 % de Bis- GMA, 25 % TEGDMA, e 25 % HEMA, em peso, acrescido de Canforoquinona e EDAB (1% /mol). Para formar os grupos experimentais seis substâncias foram adicionadas à resina base: dióxido de titânio, óxido de bismuto, sulfato de bário, quartzo, dióxido de zircônio e trifluoreto de itérbio, em diferentes concentrações. A radiopacidade foi avaliada utilizando um sistema digital com placas de fósforo VistaScan (Dürr Dental GmbH & CO. KG, Bietigheim- Bissingen, Alemanha) sendo analisadas através do software DBSWIN 4.5, quanto a densidade radiográfica. As demais propriedades avaliadas foram: grau de conversão através de FTIR; resistência à flexão, baseada na normatização da ISO 4049/2010. Radiopacidade de resinas adesivas experimentais com ao menos 30% sulfato de bário ou óxido de bismuto ou 40% de zircônia apresentaram radiopacidade semelhante a 2mm de alumínio. Resinas adesivas com ao menos 20% de fluoreto de itérbio apresentaram radiopacidade satisfatória (2mm de Al) sem influenciar outras propriedades.
The radiopacity of restorative materials should be sufficient to allow the clinician to distinguish the material from normal and demineralized tissues. It is recognized that unfilled resin adhesives are radiolucent which could be reached with radiopaquing agents’ addition. The aim of this study is to evaluate, in an experimental adhesive resin, the influence of radiopaquing agents at polymer properties. A model adhesive resin was formulated with 50% of Bis-GMA, 25% of TEGDMA, 25% of HEMA in weight, and camphorquinone and EDAB (1%mol). The experimental groups were formed with addition of six radiopaquing agents: titanium dioxide, bismuth oxide, barium sulfate, quartz, zirconium, and ytterbium trifluoride at different concentration. The radiopacity was evaluated using an aluminum step-wedge and VistaScan (Dürr Dental GmbH & CO. KG, Bietigheim-Bissingen, Alemanha) phosphorous plates radiographs digital system and DBSWIN 4.5 software. The other properties evaluated were degree of conversion with FTIR and flexural strength, based at ISO 4049/2010. Radiopacity of model adhesive resins with at least 30% of barium sulfate or bismuth oxide or 40% of zircon showed no significant differences to 2mm of aluminum. Adhesive resin with at least 20% addition of ytterbium trifluoride presented satisfactory radiopacity (Al 2mm) without influencing other properties.
APA, Harvard, Vancouver, ISO, and other styles
38

Cavazzola, Fernanda de Cássia Mortari. "Efeito da vibração sônica em adesivo autocondicionante e adesivo de frasco único na resistência de união à dentina." Pontifícia Universidade Católica do Rio Grande do Sul, 2008. http://hdl.handle.net/10923/501.

Full text
Abstract:
Made available in DSpace on 2011-12-27T14:14:25Z (GMT). No. of bitstreams: 2 000410352-0.pdf: 1564649 bytes, checksum: f945ade3456419a19d997c80c2fb43fc (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5)
Objetivo: Verificar se a aplicação dos sistemas adesivos, por meio da vibração do aparelho sônico, aumenta a resistência de união do sistema adesivo à dentina. A hipóse nula é que a resistência de união nos sistemas adesivos Single Bond e Clearfil SE Bond é similar tanto nos grupos controle quanto nos grupos que receberem tratamento sônico. Materiais e Método: Doze terceiros molares extraídos hígidos foram incluídos em resina acrílica autopolimerizável com a parte coronária do dente voltada para a sua parte superior, onde foi realizada a remoção do esmalte com lixas de carbeto de silício de granulação #600, preparando uma superfície dentinária lisa. Os dentes foram divididos em 4 grupos, onde cada sistema adesivo utilizado foi aplicado de acordo com as instruções do fabricante (aplicação dinâmica manual) e com a vibração de aparelho sônico por um dispositivo adaptador para pincel microbrush. Após a técnica adesiva, foi aplicada resina composta microhíbrida com altura de 6mm. Após o corpo de prova foi incluído completamente pela resina acrílica autopolimerizável estabilizando o material restaurador e interface adesiva ao cilíndro para os cortes seriados. Após isso, estes cilindros foram armazenados em água destilada em uma estufa de cultura a 37°C por 24 horas. Passado este período, foram confeccionados os corpos de prova para o ensaio de resistência de união por microtração com cada cilindro. Os dados obtidos foram submetidos ao teste Kolmogorov-Smirnov para verificação de normalidade. A seguir, os dados foram comparados com o teste ANOVA e Tukey (alpha=0,05). A analise estatística da fractografia, foi submetida ao teste Exato de Fisher, com nível de significância de 5% (p<0,05). Resultados: A resistência de união com a aplicação ativada pela vibração sônica foi maior do que a aplicação dinâmica manual em ambos os sistemas adesivos, apresentando diferenças estatisticamente significativas nos diferentes grupos de um mesmo adesivo. Conclusão: A utilização da aplicação sônica é um método eficaz para a otimização da resistência de união em dentina.
APA, Harvard, Vancouver, ISO, and other styles
39

Espinoza, Carlos Andres Villavicencio. "Efeito da contaminação por saliva humana na interface adesiva: resistência de união, análise de camada híbrida e conversão de sistemas adesivos." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/25/25148/tde-19022018-105444/.

Full text
Abstract:
Este estudo teve como objetivo analisar o efeito da contaminação por saliva humana na resistência de união (RU) da interface adesiva em dentina por microtração, nas características morfológicas da camada híbrida (CH) em microscopia confocal e no grau de conversão (GC) de 2 sistemas adesivos: Adper Single bond 2 (SB) e Single Bond® Universal (SU). Cento e oitenta dentes terceiros humanos hígidos foram divididos em 12 grupos (n=10), de acordo com o sistema adesivo utilizado, a presença de saliva e o tempo de armazenagem. Após o procedimento adesivo e aplicação da resina composta Filtek Z250, os dentes foram mantidos em água destilada em estufa a 37°C por 48 horas, 6 meses ou 12 meses antes de serem seccionados em palitos (0,8mm x 0,8mm, aproximadamente) para serem levados à máquina de ensaios universal Instron para os testes de microtração. Para à análise da interface adesiva em microscopia confocal de varredura a laser para verificação e mensuração de alterações internas na interface foram utilizados 60 dentes divididos em 6 grupos (n=10) de acordo com os tempos de 48 horas, 6 meses, e 12 meses respectivamente, empregando os sistemas adesivos (SB) e (SU). O efeito da presença de saliva também foi avaliado pelo grau de conversão dos adesivos, empregando-se espectroscopia de infravermelho transformada de Fourier empregando os sistema adesivos (SB) e (SU) com incorporação de saliva humana na sua composição (n=5) com concentrações 10%, 25% e 50% em vol. Para a comparação das variáveis: RU, (GC), espessura da CH, na presença de saliva e tempo de armazenamento foram utilizados os testes de Análise de Variância a três critérios e de comparações múltiplas de Tukey (p<0,05). Os valores de RU (MPa±dp: 48horas/6meses/1ano) foram: SB (43,53 ±6,0; 40,10±3,4; 38,59±5,4); SalSB (43,09±6,2; 39,86±6,6; 37,255,8); SU (42,98±4,3; 39,30±3,6; 40,44±5,7); Sal SU (44,39±4,2; 42,26±2,5; 38,26±5,7). Os Valores médios da CH (MPa±dp: 48horas/6meses/1ano) foram: SalSB (3,59±0,8; 3,59±1,0; 2,08±1,5). SalSU (1,26±0,5; 1,73±0,8; 1,07±0,3). Os valores de GC (MPa±dp: 10%/25%/50%vol) foram: SB (85,59±3,4; 49,68±12,8; 38,56±11,8); SU (85,52±3,3; 86,27±3,5; 57,82±11,1).Conclui-se, portanto, que a contaminação por saliva humana não interferiu na RU da interface dentina/resina composta após 48 horas, 6 meses e 12 meses. A morfologia da camada hibrida foi alterada pela presença da saliva nos períodos 6 e 12 meses,. O GC dos sistemas adesivos foi afetado pela presença de saliva após a polimerização imediata. Entretanto o fator tempo foi determinante para a deformação da interface dentina/resina para ambos os sistemas adesivos.
The objective of this study was to analyze the effect of human saliva contamination on bond strength of the dentin/adhesive interface, morphology of the hybrid layer by confocal microscopy and SEM analysis and degree of conversion of 2 adhesive systems: Adper Single bond 2 (SB) and Single Bond® Universal ( SU). One hundred and eighty healthy human third teeth were divided into 12 groups (n = 10), according to the adhesive system used, the presence of saliva and the storage time. After the adhesive procedure and placement of resin composite (Filtek Z250), the teeth were stored in distilled waterat 37 ° C for 48 hours, 6 months or 12 months before being cut into sticks (0.8mm x 0.8mm, approximately) to the microtensile strength tests. For the analysis of the adhesive interface in confocal microscopy of laser scanning for verification and measurement of internal interface changes, 60 teeth were used divided into 6 groups (n = 10) according to the storage time: 48 hours, 6 months, and 12 monthsand (SB) and (SU). The effect of the presence of saliva was also evaluated by the degree of conversion of the adhesives using Fourier transform infrared spectroscopy employing adhesive (SB) and (SU) systems incorporating human saliva in its composition (n = 5) with 10%, 25% and 50% vol. For the comparison of the variables: bond strength, degree of conversion, and hybrid layer thickness in the presence of saliva and storage time, the three criteria Variance Analysis and Tukey multiple comparisons tests (p <0.05) were used. The values of bond strength (MPa ± dp: 48hours / 6meses / year) were: SB (43.53 ± 6.0, 40.10 ± 3.4, 38.59 ± 5.4); SalSB (43.09 ± 6.2, 39.86 ± 6.6, 37.255.8); SU (42.98 ± 4.3, 39.30 ± 3.6, 40.44 ± 5.7); SU salt (44.39 ± 4.2, 42.26 ± 2.5, 38.26 ± 5.7). The mean values of hybrid layer thickness (MPa ± dp: 48hours / 6meses / year) were: SalSB (3.59 ± 0.8, 3.59 ± 1.0, 2.08 ± 1.5). SalSU (1.26 ± 0.5, 1.73 ± 0.8, 1.07 ± 0.3). The values of degree of conversion (MPa ± dp: 10% / 25% / 50% vol) were: SB (85.59 ± 3.4, 49.68 ± 12.8, 38.56 ± 11.8); (85.52 ± 3.3, 86.27 ± 3.5, 57.82 ± 11.1). It was therefore concluded that human saliva contamination did not interfere on bond strength of the dentin/adhesive interface after 48 hours, 6 months and 12 months. The morphology of the hybrid layer was altered by the presence of saliva after 6 and 12 months. The degree of conversion of adhesive systems was affected by the presence of saliva immediately after polymerization. However, the time factor was determinant for the dentine/resin interface deformation for both adhesive systems.
APA, Harvard, Vancouver, ISO, and other styles
40

Pereira, Cristina Alves. "Avaliação comparativa pelos testes micropush-out e micro-cisalhamento da resistência adesiva de restaurações diretas de resina composta usando diferentes sistemas adesivos." Universidade Federal de Uberlândia, 2008. https://repositorio.ufu.br/handle/123456789/16877.

Full text
Abstract:
The bond strength may be influenced by the different composition and manipulation of the adhesive systems, the dentin structure and the method of evaluation. After exposure of the occlusal dentin surface 160 third human molars were divided in 2 groups (n=80) for the micropush-out (μPBS) and microshear (μSBS) bond strength tests. For the μPBS, 4 groups (n=20) were obtained and a tapered cavity (2,5x1,5x1,0mm) was prepared on the dentin surface and restored with composite resin after treatment using different adhesive systems: Adper Single Bond, Adper Scotchbond MP, Prompt-L-Pop, AdheSE. After water storage for 24 hours, from 10 teeth per group, 1 oclusal slice (1,5 ±0,3mm) was obtained from each tooth, and the restoration submitted to vertical load. The other 10 teeth were storage for 12 months and then submitted to the same procedure. For the μSBS another 80 teeth were divided into 4 groups (n=20), the dentin surface was treated using the same adhesive systems and composite resin cylinders (1x1mm) were constructed and polymerized in a single increment onto the bonding area. Ten specimens were tested after 24 hours and 10 after 12 months of water storage. The null hypotheses were that (1) the composition and manipulation of the adhesive systems, (2) the water storage and (3) the method of evaluation might influence the bond strength of direct composite resin restorations. Results of ANOVA did not show significant difference for the storage time factor (p=.6343), but there was difference between the methods (p<.0001), with higher values for the μPBS test, and among the adhesive systems (p<.0001). The Adper Scotchbond and AdheSE systems presented higher bond strength values. Adhesive x method (p=.0002) and adhesive x method x time (p=.0037) interactions were significant, with different behaviors from adhesive systems within the method and time of evaluation. Conclusions were that the storage time might be not sufficient to result in alterations and that adhesive systems composition and manipulation might influence the bond strength. The μPBS test, presented the higher bond values with lower coefficient of variation, indicating more consistence than the μSBS test, besides of reproduce more faithfully clinical conditions.
Dentre os vários fatores que podem influenciar a resistência adesiva de diferentes sistemas adesivos à dentina estão as suas diferentes composições e manipulação, o substrato dentinário e a produção do teste. Após exposição da superfície dentinária oclusal 160 molares humanos foram divididos em 2 grupos (n=80) para os testes de micropush-out e micro-cisalhamento. Para o teste de micropush-out a superfície dentinária de 4 grupos (n=20) recebeu uma cavidade tronco-cônica (2,0x1,5x1,0mm) restaurada com resina composta após aplicação do sistema adesivo: Adper Single Bond (SLB); Adper Scotchbond MP (SMP); Prompt-L-Pop (PLP); Adhe SE (ADH). Após armazenagem em água por 24 horas, a partir de 10 dentes de cada grupo, foi obtida uma fatia oclusal (1,5 ±0,3mm) por dente cuja restauração foi submetida à carga vertical. Os outros 10 dentes de cada grupo foram armazenados por um ano e submetidos ao mesmo procedimento. Para o teste do micro-cisalhamento outros 80 dentes foram divididos em 4 grupos (n=20), a superfície dentinária foi tratada com os mesmos sistemas adesivos, e, diretamente sobre ela, cilindros de resina (1x1 mm) foram construídos e polimerizados em incremento único. Dez amostras de cada grupo foram testadas após 24 horas e as outras após um ano de armazenagem. As hipóteses nulas foram que (1) a composição e manipulação dos sistemas adesivos, (2) a armazenagem em água, e (3) o método de avaliação, não influenciam a resistência de união das restaurações de resina composta direta. A ANOVA não mostrou diferença significante para o fator tempo de armazenagem (p=0,6343), mas houve diferença entre os métodos de avaliação (p<0,0001), com valores mais altos para o micropush-out, e entre os adesivos (p<0,0001). O Adper Scotchbond MP e AdheSE apresentaram resultados melhores que os outros sistemas testados. As interações adesivos x métodos (p=0,0002) e adesivos x métodos x tempo (p=0,0037) foram significativas com comportamentos diferentes dos adesivos dentro do método e do tempo de armazenagem. Os resultados indicaram que a composição e manipulação dos adesivos influenciaram a resistência de união. O método micropush-out, além de resultar em valores mais altos de união, apresentou também menor coeficiente de variação, indicando ser mais consistente que o microcisalhamento, além de simular mais fielmente as condições clínicas. O tempo de armazenagem avaliado pode não ter sido suficiente para promover alteração que pudesse ser identificada no teste de resistência adesiva.
Mestre em Odontologia
APA, Harvard, Vancouver, ISO, and other styles
41

Lima, Luiz Rafael Calixto [UNESP]. "Avaliação da efetividade de cimentos resinosos auto-adesivos aplicados sob diferentes pré-tratamentos da dentina radicular na resistência adesiva de pinos de fibra de vidro." Universidade Estadual Paulista (UNESP), 2013. http://hdl.handle.net/11449/108401.

Full text
Abstract:
Made available in DSpace on 2014-08-13T14:50:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-12Bitstream added on 2014-08-13T18:01:15Z : No. of bitstreams: 1 000732205_20140909.pdf: 527845 bytes, checksum: a4c9483a6f8f4f270ac1d61032aec827 (MD5) Bitstreams deleted on 2014-10-03T16:24:43Z: 000732205_20140909.pdf,Bitstream added on 2014-10-03T16:27:41Z : No. of bitstreams: 2 000732205_20140909.pdf.txt: 17075 bytes, checksum: 2d10283196b7e27311acd4c2cfff812d (MD5) 000732205.pdf: 890728 bytes, checksum: 73e31941709b20f0f746950e7ee144ad (MD5) Bitstreams deleted on 2014-10-03T16:33:18Z: 000732205.pdf,Bitstream added on 2014-10-03T16:43:31Z : No. of bitstreams: 2 000732205_20140909.pdf.txt: 17075 bytes, checksum: 2d10283196b7e27311acd4c2cfff812d (MD5) 000732205.pdf: 890728 bytes, checksum: 73e31941709b20f0f746950e7ee144ad (MD5) Bitstreams deleted on 2014-10-03T16:48:57Z: 000732205.pdf,Bitstream added on 2014-10-03T16:49:48Z : No. of bitstreams: 1 000732205.pdf: 890728 bytes, checksum: 73e31941709b20f0f746950e7ee144ad (MD5) Bitstreams deleted on 2014-10-27T11:47:13Z: 000732205.pdf,Bitstream added on 2014-10-27T11:48:06Z : No. of bitstreams: 1 000732205.pdf: 890728 bytes, checksum: 73e31941709b20f0f746950e7ee144ad (MD5)
A retenção de pinos pré-fabricados de fibra de vidro utilizados na restauração de dentes com tratamento endodôntico é baseada na sua união às superfícies das paredes do canal radicular por meio dos agentes de fixação resinosos. Os cimentos resinosos auto-adesivos surgiram recentemente com o objetivo de simplificar o procedimento de cimentação, porém seu desempenho clínico ainda é controverso na literatura. Assim, o propósito desse trabalho é avaliar a efetividade de cimentos autoadesivos sob diferentes condições de tratamento da dentina na resistência à extrusão de pinos de fibra de vidro cimentados intrarradicularmente. Foi avaliada a resistência adesiva (push-out) de pinos de fibra de vidro utilizando cimentos resinosos auto-adesivos e, diferentes substâncias para o tratamento dentinário (ácido poliacrílico 11,5%; EDTA 17% e hipoclorito de sódio) previamente ao procedimento de cimentação. Foi avaliado também o tipo de falha entre o pino/cimento/dentina através de microscopia óptica. Foram utilizados 216 unidades experimentais, em forma de discos com aproximadamente 1 mm de espessura, retirados de 72 raízes bovinas restauradas com retenções intra-radiculares. Foi utilizada uma máquina de ensaios universais MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para Mpa. Os dados foram submetidos ao teste kruskall wallis com post-hoc com teste dunn, com nível de significância de 5%. Os resultados mostraram que o pré-tratamento dentinário não influenciou na resistência adesiva, e que o cimento auto-adesivo RelyX U100 parece ser uma opção viável na cimentação de pinos de fibra.
The retention of prefabricated fiberglass posts used in the restoration of endodontically treated teeth is dependent on their bond between the surface of the post and the root canal walls by means of resin cements. The self-adhesive resin cements have recently introduced to simplify the procedure for cementing, but their clinical performance is still controversial in the literature. Thus, the objective of this study is to evaluate the effectiveness of self-adhesive cements under different pretreatment of dentin in the resistance to extrusion of fiberglass posts. Prior to cementing procedure, the pre-treatment of dentin was performed with 11.5% polyacrylic acid, 17% EDTA or sodium hypochlorite. The type of failure between the post/cement/dentin was evaluated by steriomicroscopy. Two hundred and sixteen bovine dentin discs were used. The disks had approximately 1 mm of thickness and they were taken from 72 bovine roots restored with intraradicular retentions. It was employed a universal testing machine MTS 810 Material Test System at a speed of 0.5 mm/min-1 with a load cell of 50 kg to evaluate the push-out resistance in different thirds of each sample . The values of resistance in kgf were converted to Mpa. Data were submitted to Kruskal-Wallis test with Dunn post-hoc test with significance level of 5%. The results showed that pre-treatment had no effect on dentin bond strength, and that the self-adhesive cement RelyX U100 appears to be a viable option in the cementation of fiber post.
APA, Harvard, Vancouver, ISO, and other styles
42

Macedo, Manoel Roberto de Paula. "A importância de alguns adesivos dentais e de vários tratamentos da superfície sobre a dentina humana in vitro. Análise da resistência adesiva por micro-cisalhamento." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/23/23134/tde-08042009-152846/.

Full text
Abstract:
O objetivo deste trabalho foi estudar a ação sobre a dentina humana (in vitro) de vários tratamentos de superfície: Lixa, IADR-GM, CVDt e CVDi e de alguns adesivos dentais: Adper Sigle Bond 2 (SB), Clearfil SE Bond (CF) e Adper Prompt L-Pop (PL) avaliando: rugosidade e resistência adesiva por micro-cisalhamento. Foram utilizados 72 terceiros molares hígidos que foram divididos ao meio. As superfícies oclusais das 144 metades dentais foram removidas e padronizadas com Lixa #600. Após receberem os tratamentos de superfície citados, foi avaliada a rugosidade média superficial (Ra) da dentina. Em seguida realizou-se a hibridização e a confecção dos cilindros de resina composta (RC) para finalizar o preparo dos corpos de prova (cps). Após armazenagem de 24h em água destilada a 370C realizou-se o teste de micro-cisalhamento com velocidade de deslocamento de 1mm/min. Os resultados foram submetidos a testes de analise estatística (ANOVA) onde foi comprovado que a menor Ra foi encontrada nas superfícies instrumentadas com Lixa #600 seguida pelo CVDi, IADR-GM que apresentaram rugosidade intermediaria e se igualaram e pelo CVDt que produziram as superfícies mais rugosas. Já para o tratamento de superfície, o CVDi foi que apontou os piores valores de resistência de adesão que com Lixa e IADR-GM. Nos resultados para os adesivos, o PL apresentou valores de resistência à união inferiores ao SB e CF que se igualaram. Já para a interação entre os tratamentos de superfície e os adesivos não houve diferenças estatisticamente significantes entre os grupos tratados com Lixa #600, IADR-GM e CVDt e hibridizados com SB ou CF. Concluiu-se: que a Ra produzida em dentina pelo CVD variou de acordo com o tipo de movimento (CVDt produz maior rugosidade que o CVDi); que não foi possível estabelecer uma correlação entre Ra e valores de resistência adesiva; que o PL apresentou valores de resistência à adesão inferiores aos obtidos pelos adesivos SB e CF; que a interação dos tratamentos Lixa, IADR-GM e CVDt com os três adesivos (SB, CF, PL) mostrou valores mais altos para o SB e CF que se igualaram e menores para o PL; que o fator tratamento não produziu diferença de resistência adesiva para o adesivo CF e o mesmo ocorreu com o PL.
The aim of this in vitro study was to evaluate the micro-shear bond strength and the roughness to human dentin using different instrumentations (SiC #600, diamond rotary bur, CVDt and CVDi) and three dentin adhesive/composite resin systems: Adper Sigle Bond 2 (SB), Clearfil SE Bond (CF) e Adper Prompt L-Pop (PL). Seventy-two third molars were split in the middle. The oclusal third from the one hundred and forty and four halves were removed and standardized using the SiC #600. After the prepared surfaces, which were analyzed the roughness average (Ra) with a surface perfilometer and hybridization. The specimens were then stored in distillated water for 24 hours at 370C. The specimens were then were attached to a micro-shear apparatus and subjected to a micro-shear strength test at a crosshead speed of 1mm/min until failure occurred. The two-way ANOVA indicated that there was significant differences in average roughness between the instrumentations which SiC #600 was the smoothest surface. No differences were detected between dentin surface prepared with diamond bur and CVDi (intermediate in the roughness assessment) and the CVDt gave the roughest surface. The bond strengths varied slightly, though dentin instrumentations with CVDi showed the lowest values than the surfaces prepared with SiC #600 and diamond bur. The bond strengths varied slightly, though adhesives, PL showed lower micro-shear bond strength than SB and CF, which were no significant relevance. The interaction of SiC #600, diamond bur and CVDt using SB and CF showed no significant difference in micro-shear bond strength and higher than PL. The instrumentation showed no significant differences in micro-shear bond strength using CF and PL.
APA, Harvard, Vancouver, ISO, and other styles
43

Lima, Luiz Rafael Calixto. "Avaliação da efetividade de cimentos resinosos auto-adesivos aplicados sob diferentes pré-tratamentos da dentina radicular na resistência adesiva de pinos de fibra de vidro /." Araraquara : [s.n.], 2013. http://hdl.handle.net/11449/108401.

Full text
Abstract:
Orientador: Marcelo Ferrarezi de andrade
Banca: Edson Alves de Campos
Banca: José Roberto Cury Saad
Banca: Paulo Sérgio Quagliatto
Banca: Mânio de Carvalho Tibúrcio
Resumo: A retenção de pinos pré-fabricados de fibra de vidro utilizados na restauração de dentes com tratamento endodôntico é baseada na sua união às superfícies das paredes do canal radicular por meio dos agentes de fixação resinosos. Os cimentos resinosos auto-adesivos surgiram recentemente com o objetivo de simplificar o procedimento de cimentação, porém seu desempenho clínico ainda é controverso na literatura. Assim, o propósito desse trabalho é avaliar a efetividade de cimentos autoadesivos sob diferentes condições de tratamento da dentina na resistência à extrusão de pinos de fibra de vidro cimentados intrarradicularmente. Foi avaliada a resistência adesiva (push-out) de pinos de fibra de vidro utilizando cimentos resinosos auto-adesivos e, diferentes substâncias para o tratamento dentinário (ácido poliacrílico 11,5%; EDTA 17% e hipoclorito de sódio) previamente ao procedimento de cimentação. Foi avaliado também o tipo de falha entre o pino/cimento/dentina através de microscopia óptica. Foram utilizados 216 unidades experimentais, em forma de discos com aproximadamente 1 mm de espessura, retirados de 72 raízes bovinas restauradas com retenções intra-radiculares. Foi utilizada uma máquina de ensaios universais MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para Mpa. Os dados foram submetidos ao teste kruskall wallis com post-hoc com teste dunn, com nível de significância de 5%. Os resultados mostraram que o pré-tratamento dentinário não influenciou na resistência adesiva, e que o cimento auto-adesivo RelyX U100 parece ser uma opção viável na cimentação de pinos de fibra.
Abstract: The retention of prefabricated fiberglass posts used in the restoration of endodontically treated teeth is dependent on their bond between the surface of the post and the root canal walls by means of resin cements. The self-adhesive resin cements have recently introduced to simplify the procedure for cementing, but their clinical performance is still controversial in the literature. Thus, the objective of this study is to evaluate the effectiveness of self-adhesive cements under different pretreatment of dentin in the resistance to extrusion of fiberglass posts. Prior to cementing procedure, the pre-treatment of dentin was performed with 11.5% polyacrylic acid, 17% EDTA or sodium hypochlorite. The type of failure between the post/cement/dentin was evaluated by steriomicroscopy. Two hundred and sixteen bovine dentin discs were used. The disks had approximately 1 mm of thickness and they were taken from 72 bovine roots restored with intraradicular retentions. It was employed a universal testing machine MTS 810 Material Test System at a speed of 0.5 mm/min-1 with a load cell of 50 kg to evaluate the push-out resistance in different thirds of each sample . The values of resistance in kgf were converted to Mpa. Data were submitted to Kruskal-Wallis test with Dunn post-hoc test with significance level of 5%. The results showed that pre-treatment had no effect on dentin bond strength, and that the self-adhesive cement RelyX U100 appears to be a viable option in the cementation of fiber post.
Doutor
APA, Harvard, Vancouver, ISO, and other styles
44

Lopes, Guilherme Carpena. "Adesão à dentina." Florianópolis, SC, 2003. http://repositorio.ufsc.br/xmlui/handle/123456789/85632.

Full text
Abstract:
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia.
Made available in DSpace on 2012-10-20T20:55:16Z (GMT). No. of bitstreams: 0
O objetivo foi verificar se há diferença na capacidade de união ao substrato dentinário envelhecido quando comparado com o jovem; e, se o aumento do tempo de condicionamento poderá resultar em uma maior resistência de adesão a este substrato envelhecido, sem prejudicar a união ao substrato jovem. Foram realizados testes de resistência de união, verificação da dureza dentinária e microscopia eletrônica de varredura da interface adesiva. A dentina envelhecida condicionada por 15s obteve resistência de união estatisticamente menor que todos os outros grupos. A dureza da dentina envelhecida foi maior do que a dentina jovem. O maior conteúdo mineral na dentina envelhecida dificulta a união, resultando em mais baixa m-TBS quando o condicionamento é feito por apenas 15s. Por outro lado, a duplicação do tempo de condicionamento resulta em mais adequada adesão à dentina envelhecida alcançando médias similares à dentina jovem.
APA, Harvard, Vancouver, ISO, and other styles
45

Victorino, Keli Regina. "Influência de diferentes protocolos de limpeza e momento do condicionamento ácido sobre a interface adesiva e resistência de união do sistema adesivo na dentina impregnada com diferentes cimentos endodonticos /." Araraquara, 2016. http://hdl.handle.net/11449/144727.

Full text
Abstract:
Orientador: Milton Carlos Kuga
Resumo: O objetivo dos estudos são avaliar a capacidade de limpeza superfie dentinaria impregnada por AH Plus e MTA Fillapex, proporcionada pelo etanol a 95,0% (E) ou xilol (X) e seus efeitos sobre a interface adesiva e resistência de união do sistema adesivo etch-and-rinse, com condicionamento ácido (CA) imediato (I) ou após 7 dias (T). Publicação 1: Cinquenta espécimes de coroas de incisivos bovinos foram impregnados com o cimento e divididos em quatro grupos (n=10): G1(EICA), E e CA imediato; G2(XICA), X e CA imediato; G3(ETCA), E e CA após 7 dias e G4(XTCA), X e CA após 7 dias e G5(controle), CA imediato. Escores foram atribuídos, em relação à persistência de resíduos na dentina, por análises em MEV(500X). Cinquenta fragmentos foram preparados, restaurados com resina composta e obtidas imagens em microscopia confocal laser (1024X), para avaliar a formação de camada hibrida, mensurada no Image J. Cinquenta fragmentos foram igualmente preparados e submetidos ao teste de microcisalhamento para avaliar os efeitos sobre a resistência de união do sistema adesivo etch-and-rinse na dentina. Em relação à persistência de resíduos, G1 e G2 apresentaram maiores valores que G3 e G4 (P<0,05). Entre G1 e G2 ou G3 e G4 não houve diferença (P>0,05). Em relação à interface adesiva, a extensão da formação da camada hibrida foi G5>G4=G3=G2=G1. Em relação à resistência de união do sistema adesivo G5=G4 e G4=G2 (P=0,05), porém G5>G2 (P<0,05) e G1=G2=G3 (P>0,05). Publicação 2: Cinquenta espécimes de co... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The aim was to evaluate the cleaning protocol in dentin impregnated with different endodontic sealers using 95% ethanol (E) or xylol (X) and its effects on adhesive interface and on bond strength of etch-and-rinse adhesive system when the acid etching (AE) was immediately (I) carried out or 7 days delay (D).Publication 1:Fifty bovine incisors specimens were impregnated with epoxy resin-based sealer (AH Plus) sealer and divided into four groups (n = 10): G1 (EIAE); G2 (XIAE); G3 (EDAE); G4 (XDAE) and G5 (control, IAE). The persistence of residues was evaluated using scores by SEM (500X). Fifty fragments were prepared similarly as described before, restored with composite resin and subjected to laser confocal microscopy (1024X). The hybrid layer formation was measured using Image J program. Another fifty fragments were similarly prepared and submitted to microshear bond test to access the bond strength of etch-and-rinse adhesive system to dentin.Regarding the persistence of residues, G1 and G2 presented higher values than G3 and G4 (P<0.05). No statistical difference was found between G1 and G2 or G3 and G4 (P>0.05). Regarding the adhesive interface, the extend of hybrid layer formation G5>G4=G3=G2=G1.Regarding the bond strength of adhesive system: G5=G4 and G4=G2 (P=0.05), however G5>G2 (P<0.05) and G1=G2=G3 (P>0.05).Publication 2: Fifty bovine crown specimens were impregnated with mineral trioxide aggregate-based (MTA) sealer and divided into four groups (n = 10): G1 (EIAE); G2 (XIAE); G3 (EDAE); G4 (XDAE) and G5 (control, IAE). The residues persistence using scores by SEM (500x). Fifty fragments were prepared similarly as described before and subjected to laser confocal microscopy (1024X). The hybrid layer formation was measured using Image J program. Fifty fragments were similarly prepared and submitted to microshear bond test to access the bond strength of etch-and-rinse ...(Complete abstract electronic access below)
Doutor
APA, Harvard, Vancouver, ISO, and other styles
46

Marson, Fabiano Carlos. "Resistência adesiva a microtração de cimentos resinosos na interface entre cerâmica e dentina." Florianópolis, SC, 2003. http://repositorio.ufsc.br/xmlui/handle/123456789/86404.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de de Pós-Graduação em Odontologia.
Made available in DSpace on 2012-10-21T06:38:14Z (GMT). No. of bitstreams: 1 199914.pdf: 6892181 bytes, checksum: 7e6560fa39e164281c00aad755ae619a (MD5)
O propósito desta investigação, in vitro, foi avaliar a resistência de união a microtração (µTBS) de 4 cimentos resinosos, nas interfaces adesivas entre cerâmica (IPS Empress 2) e dentina. Foram selecionados 16 molares humanos hígidos e divididos aleatoriamente em 4 grupos. Grupo1 - (RX) Single Bond + Rely X, CRA; Grupo 2 - (VL) Excite DSC + Variolink II ; Grupo 3 - (PN) ED Primer + Panavia ; e Grupo 4 - (UC) Unicem. Foram analisados os resultados através do teste estatístico de análise de variância, seguido pelo teste de Tukey post hot. Medias em MPa ± desvio-padrão: RX (17,90a ± 3,53); VL (15,95b ± 3,07); PN (15,58b ± 2,90); UC (8,41c ± 2,54). Letras subscritas indicam valores homogêneos através do teste de Tukey, que demonstraram diferença entre os grupos, onde o cimento resinoso Rely X CRA obteve maior resistência adesiva a microtração. Variolink II e Panavia F resultaram em valores similares e a menor resistência adesiva foi do cimento resinoso Unicem.
APA, Harvard, Vancouver, ISO, and other styles
47

Jacques, Paula [UNESP]. "Adesão à dentina após remoção mecânica ou química de tecido cariado." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/104259.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-16Bitstream added on 2014-06-13T20:04:53Z : No. of bitstreams: 1 jacques_p_dr_arafo.pdf: 4775978 bytes, checksum: 18cc404903316b63486985e85026922c (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
A influência de diferentes métodos de remoção da dentina artificialmente cariada sobre a resistência de união de um sistema adesivo convencional simplificado e de um autocondicionante foi avaliada por meio de ensaio mecânico de microtração. Trinta e dois terceiros molares humanos foram aleatoriamente distribuídos em 8 grupos experimentais, de acordo com o tipo de material (sistema adesivo) e o substrato dentinário. O grupo controle para cada sistema adesivo foi representado por sua aplicação sobre a dentina hígida. Foram avaliados os sistemas adesivos Adper Single Bond (SB) e Clearfil SE Bond (CSE), e quatro tipos de substrato dentinário: a) hígido e afetado por cárie após diferentes métodos de remoção de tecido infectado, b) método mecânico manual; c) método mecânico rotatório; e d) método químicomecânico representado pelo Carisolv . Superfícies planas de dentina foram submetidas ao desenvolvimento artificial de cárie pela exposição a Streptococcus mutans. Os sistemas adesivos foram aplicados sobre a superfície dentinária resultante após a utilização dos diferentes métodos para remoção da cárie artificial ou sobre a dentina hígida, recebendo em seguida restauração de resina composta Z250. Os dentes restaurados foram mantidos por 24 horas à 37º C, seccionados em forma de palitos, com área de superfície aderida medindo aproximadamente 0,49mm2 e submetidos ao ensaio mecânico de microtração. Quando os sistemas adesivos foram aplicados em dentina hígida, ambos resultaram em resistência de união não diferente entre si e superior à observada para os grupos onde tinham sido aplicados em dentina cariada, independente do método de remoção de tecido cariado utilizado. Para CSE, a remoção com cureta resultou nos menores valores de resistência de união, estatisticamente inferior aos demais grupos onde foi utilizado. A resistência de... .
The purpose of this investigation was to evaluate the influence of different removal methods of artificially carious dentin on the bond strength of a one-step etch and rinse and a two-step self-etching primer bonding agent to caries-affected dentin. Thirty-two human third molars were randomly distributed into 8 groups, according to the bonding agent and the dentin substrartes. The control group was represented by the application of the bonding agents to sound dentin. The bonding agents evaluated were, Adper Single Bond (SB) and Clearfil SE Bond (CSE) and the dentin substrates were: a) sound dentin; b) dentin resulting from hand excavation, c) bur excavation and d) Carisolv gel excavation of the carious tissue. Flat dentin surfaces were submitted to an in vitro cariogenic bacterial model to create caries-like lesions. After caries removal, the bonding agents were applied on the caries-affected dentin according to the manufacturers' directions. Composite build-ups were constructed and the teeth were stored in water at 37°C for 24 hrs. Then they were sectioned in the x-y directions to produce beams with a crosssectional area of 0.49 mm2. The specimens were subjected to the microtensile test at a cross-head speed of 0.5 mm/min until failure. For both dentin bonding agents, the highest bond strength was produced in sound dentin when compared to caries159 affected dentin, irrespective of the method of caries removal. For CSE, caries removal using spoon excavators produced the lowest bond strengths (p<0.05) while the adhesive performance of SB was not affected by the caries removal method, although a trend towards lower values was observed when Carisolv was used. For all groups, the predominant mode of failure was adhesive. In conclusion, for both dentin bonding agents evaluated, bond strength to caries-affected dentin was significantly lower than to sound dentin. Caries removal using spoon... (Complete abstract, click electronic address below).
APA, Harvard, Vancouver, ISO, and other styles
48

Pomacóndor, Hernández César Alberto 1982. "Efeito da clorexidina na resistência de união entre adesivo autocondicionante e dentina." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288154.

Full text
Abstract:
Orientador: Mario Fernando de Goes
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-18T00:53:20Z (GMT). No. of bitstreams: 1 PomacondorHernandez_CesarAlberto_M.pdf: 1946502 bytes, checksum: 842f8e2e23f8ff6c74e3ea3a3c2f7637 (MD5) Previous issue date: 2011
Resumo: Na tentativa de prolongar a durabilidade da união resina-dentina, a clorexidina aparece como uma alternativa para preservar a integridade do componente colágeno não envolvido pela camada híbrida. O presente estudo teve como objetivo avaliar o efeito da clorexidina na interação entre o adesivo autocondicionante de dois frascos Adper SE Plus (3M ESPE) e a dentina nas variáveis: a) resistência de união (RU) após 1 dia, 3 meses e 6 meses de armazenamento em água, e b) padrão de fratura. Foram obtidos oito terceiros molares humanos recém extraídos e livres de cárie. O esmalte oclusal e a raiz foram removidos para obter um bloco de dentina de 4mm de espessura com uma superfície plana em dentina média. Cada bloco foi cortado longitudinalmente em duas metades resultando em oito hemiblocos para cada um dos Grupos Controle (C) e Experimental (CHX). Para o Grupo Controle, o Adper SE Plus foi aplicado seguindo as instruções do fabricante: 1 - aplicação do Líquido A, 2 - aplicação ativa do Líquido B por 20s, 3 - leve jato de ar comprimido durante 10s, 4 - aplicação de uma segunda camada de Líquido B, 5 - leve jato de ar comprimido. O adesivo foi fotoativado durante 10s usando a unidade de luz visível Elipar Freelight 2 (3M ESPE) com intensidade de 900 mW/cm2. Para o Grupo Experimental, foi realizado o mesmo procedimento substituindo o Líquido A por uma solução aquosa de digluconato de clorexidina a 2% em peso. Foram construídos blocos de resina composta Filtek Z250 (3M ESPE) sobre a dentina em seis incrementos de 1mm sendo fotoativados durante 20s cada. Depois de 24 horas de armazenamento em água destilada a 37°C, os hemiblocos restaurados foram seccionados perpendiculares à região adesiva nos sentidos mesiodistal e bucolingual e obtidos de 8 a 10 palitos de 0,9mm2 (±0,2mm2), os quais foram divididos aleatoriamente em três grupos de 2 a 4 palitos cada e avaliados após 1 dia, 3 meses e 6 meses de armazenamento em água destilada a 37°C. Para o teste de microtração cada palito foi submetido à tração sob velocidade de 0,5mm/min em uma máquina de ensaios universais. Os valores de RU foram submetidos à Análise de Variância de dois fatores para medidas repetidas (?=0,05), e os padrões de fratura classificados em Microscópio Eletrônico de Varredura. O Grupo Controle apresentou valores de RU estatisticamente não diferentes entre si após 1 dia, 3 meses e 6 meses de armazenamento (46,43±11,46 MPa; 50,02±13,84 MPa; 45,18±17,92 MPa, respectivamente). Os valores de RU do Grupo Experimental também resultaram estatisticamente não diferentes entre si nos mesmos tempos de armazenamento (37,22±10,45 MPa; 47,29±12,67 MPa; 40,22±10,01 MPa, respectivamente). Não houve diferença estatística nos valores de RU entre os Grupos Controle e Experimental. Houve predominância de padrões de fraturas coesiva no adesivo, e mista coesiva no adesivo e na resina composta em ambos os grupos e em todos os tempos de armazenamento. Dentro das condições deste estudo, conclui-se que a RU à dentina do Adper SE Plus não diminuiu com o tempo, e não foi negativamente afetada pela clorexidina a 2%
Abstract: In the search for durability of resin-dentin bond, chlorhexidine appears as an alternative to preserve integrity of collagen component not involved by the hybrid layer. This study aimed to evaluate the effect of chlorhexidine in the interaction between two-bottle self-etching adhesive Adper SE Plus (3M ESPE) and dentin, in terms of bond strength (BS) after 1 day, 3 months and 6 months of water storage, and fracture mode analysis. Eight fresh caries-free human third molars were obtained. The occlusal enamel and roots were removed to obtain a 4mm-thick dentin block with a flat surface in middle dentin. Each dentin block was cut longitudinally into halves resulting in eight hemi-blocks for each of the Control (C) and Experimental (CHX) Groups. For the Control Group, Adper SE Plus was applied following the manufacturer's instructions: 1 - application of Liquid A, 2 - active application of Liquid B for 20s, 3 - gentle compressed air stream for 10s, 4 - application of a second layer of Liquid B, 5 - gentle compressed air stream. The adhesive was light cured for 10s using light unit Elipar Freelight 2 (3M ESPE) with a minimum intensity of 900 mW/cm2. For the Experimental Group, it was performed the same procedure replacing the Liquid A with a solution of 2 wt% chlorhexidine digluconate. Resin composite build-ups were constructed with Filtek Z250 resin composite (3M ESPE) in six increments of 1mm and were light cured for 20s each. After 24 hours storage in distilled water at 37°C, restored hemi-blocks were sectioned perpendicular to the adhesive region in mesiodistal and buccolingual directions and were obtained 8 to 10 beams of 0.9mm2 (±0.2mm2), which were randomly divided into three groups of 2 to 4 beams and evaluated after 1 day, 3 months and 6 months of storage in distilled water at 37°C. For the microtensile test, each beam was tested on tensile until failure at a crosshead speed of 0.5mm/min in a universal testing machine. The BS values were subjected to two-way repeated measures ANOVA (?=0.05), and fracture mode classified in Scanning Electron Microscope. The Control Group had BS values not statistically different from each other after 1 day, 3 months and 6 months of storage (46,43±11,46 MPa; 50,02±13,84 MPa; 45,18±17,92 MPa, respectively). The BS in the Experimental Group also resulted not statistically different from each other at the same times of storage (37,22±10,45 MPa; 47,29±12,67 MPa; 40,22±10,01 MPa, respectively). There was no statistical difference in BS values between Control and Experimental Groups. There was a predominance of cohesive failure within adhesive resin, and mixed cohesive failure within adhesive resin and resin composite in both groups at all storage times. Under the conditions of this study, it can be concluded that BS of Adper SE Plus to dentin did not diminish with time, and was not adversely affected by 2% chlorhexidine
Mestrado
Materiais Dentarios
Mestre em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
49

Terada, Raquel Sano Suga. "Mapeamento da variação regional da resistência adesiva em superfícies planas de dentina." Universidade de São Paulo, 2001. http://www.teses.usp.br/teses/disponiveis/25/25131/tde-11032005-101633/.

Full text
Abstract:
O presente trabalho avaliou a influência das variações morfológicas do substrato dentinário na resistência de união à microtração de três sistemas adesivos resinosos: Clearfil Liner Bond 2V, One-Step e Single Bond, empregando como substrato superfícies planas de dentina. Para o preparo e exposição da superfície de dentina, o esmalte oclusal foi desgastado com lixas de carbureto de silício de granulação 320 e 600. Doze dentes foram tratados com um dos sistemas adesivos e foi aplicada uma camada de 1 centímetro de altura em resina composta Z100, pela técnica incremental. Após armazenagem em água destilada em estufa a 37ºC por 24 horas, os espécimes foram preparados para serem submetidos ao teste de microtração. Utilizando-se uma máquina de cortes seriados, os dentes foram fatiados em espessuras de aproximadamente 0,8 mm nos sentidos mésiodistal e vestíbulo-lingual, obtendo-se médias de áreas de adesão de 0,7 mm2. Foram obtidos, em média, 23 espécimes por dente. Identificando-se cada espécime através de um código de cores, a superfície de cada dente foi mapeada. Para a leitura da resistência de união, cada espécime em forma de “palito” foi afixado individualmente em um dispositivo de microtração, Bencor Multi-T, de modo a posicionar a área de adesão perpendicularmente ao longo eixo do espécime. Após o teste, o modo de fratura da interface adesiva foi avaliado. Os resultados obtidos permitiram concluir que existe uma variação regional da resistência de união em superfícies planas de dentina. Independentemente do sistema adesivo empregado, a variação da resistência de união encontrada em superfícies planas de dentina foi determinada por variações no substrato dentinário.Comparando-se a resistência de união entre os materiais, os sistemas One-Step (53,97 ± 12,58 MPa) e Single Bond (52,59 ± 17,67 MPa) apresentaram uma resistência semelhante e estatisticamente superior ao sistema Clearfil Liner Bond 2V (32,90 ± 12,43 MPa). Comparando-se a resistência de união à dentina central e à dentina periférica, os três materiais não apresentaram uma diferença estatisticamente significante.
The present work evaluated the influence of morphological variations of the dentinal substrate in the microtensile adhesive strength of three adhesive systems: Clearfil Liner Bond 2V, One-Step and Single Bond, using flat dentin surfaces. For the preparation and exposure of the dentin surface, the occlusal enamel was ground with 320 and 600 – grit SiC paper. The teeth were treated with one of the adhesive systems and a 1cm thick layer of Z100 resin composite was built up on the surface. After storage in distilled water at 37ºC for 24 hours, the specimens were prepared to be subjected to the microtensile test. With the aid of a micrometer the teeth were serially sectioned in both “x” and “y” directions to result in several bonded sticks of approximately 0.7 mm2 of cross-sectional area. Approximately twenty-three specimens per tooth were obtained. Each specimen was identified by a color code and the flat dentin surface was mapped. For the reading of the adhesive strength, each bonded stick was individually gluded to a Bencor Multi-T microtensile device with the adhesive area perpendicularly oriented to the long axis of the device. After testing, the mode of fracture of the adhesive interface was evaluated. The conclusions of this study were: there is a regional variance in the adhesive strenght on a flat dentin surface; regardless of the adhesive system used, the variation of the adhesive strength found on flat dentin surfaces was determined by variations in the dentinal substrate; when comparing the adhesive strength among the materials, One-Step (53,97 MPa ± 12,58) and Single Bond (52,59 MPa ± 17,67) systems presented a adhesive strength similar and statistically higher than the Clearfi Liner Bond 2V (32,90 MPa ± 12,43) system; when comparing the adhesive strength to both central and peripheral dentin, the three materials did not present any statistically significant differences.
APA, Harvard, Vancouver, ISO, and other styles
50

Tedesco, Maybell. "Análise da interface adesiva de materiais obturadores à dentina do canal radicular." reponame:Repositório Institucional da UFSC, 2016. https://repositorio.ufsc.br/xmlui/handle/123456789/168243.

Full text
Abstract:
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016.
Made available in DSpace on 2016-09-20T05:06:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2016Bitstream added on 2017-04-04T04:10:03Z : No. of bitstreams: 1 340360.pdf: 2069422 bytes, checksum: 236ac1415e494885dedbc502f10fe93e (MD5)
A adesão em endodontia é um processo complexo que depende de fatores químicos e mecânicos relativos à interação dos cimentos endodônticos à dentina das paredes do canal radicular. O material obturador firmemente aderido à dentina contribui para o preenchimento tridimensional do canal e longevidade da obturação. Estudos comparativos com diferentes materiais e métodos observacionais são essenciais para a avaliação e desenvolvimento de novos produtos. Sendo assim, os objetivos do presente estudo, ex vivo e in vitro, foram: 1º- Comparar a acurácia da microscopia eletrônica de varredura (MEV) com a microscopia de varredura a laser confocal (Confocal) na análise da interface adesiva e penetração intratubular de dois cimentos endodônticos, AH Plus e Endofill; 2º- Avaliar a existência de correlação entre resistência de união à dentina e penetração intratubular de três cimentos endodônticos: Endofill, AH Plus e MTA Fillapex por meio dos testes de push-out e análise com Confocal; 3º- Avaliar a influência da adição do corante fluorescente, rodamina B, nas propriedades físicas-químicas de dois cimentos endodônticos, AH Plus e MTA Fillapex. Embora os objetivos sejam correlacionados, os experimentos tiveram metodologias e amostras distintas, o que fez com que os resultados do presente estudo fossem apresentados em três artigos. Cada artigo foi detalhado de acordo com os objetivos propostos, recebeu análise estatística dos resultados obtidos e discussão embasada na literatura vigente.

Abstract : The adhesion in endodontics is a complex process witch depends on physical and mechanical factors related to the interaction between endodontic sealer to dentine canal walls. The filling material firmly attached to dentin contribute to the tridimensional filling and longevity of treatment. Comparative studies with different materials and observational methods are essential to evaluate and development of new products. Therefore, the objectives of the present study, ex vivo e in vitro were: 1º- Compare the acuracy of the scanning electronic microscopy evaluation (SEM) with confocal laser scanning microscopy (Confocal) on the adhesive interface and intratubular penetration evaluation of two endodontic sealers, AH Plus and Endofill; 2º- Evaluate the existence of a correlation between bond strength (BS) and intratubular penetration of three endodontic sealers: Endofill, AH Plus and MTA Fillapex, through push-out and Confocal evaluation; 3º- Evaluate the influence of the addition of a fluorescent dye, rhodamine B, in the physical-chemical properties of two endodontic sealers, AH Plus e MTA Fillapex. Although the objectives are correlated, the experiments had different methodology and samples; that makes the results of the present study be presented in three individual articles. Each article was detailed according to the goals proposed and have received statistical analysis of the data and discussion based on the current literature.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography