Academic literature on the topic 'Adesivi dentali'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Adesivi dentali.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Adesivi dentali"

1

Alcântara, V. M. O., M. A. G. Moreira, V. A. Castro, and M. A. D. Araújo. "Sistemas Adesivos Autocondicionantes: uma Revisão de Literatura." Journal of Health Sciences 19, no. 5 (February 23, 2018): 231. http://dx.doi.org/10.17921/2447-8938.2017v19n5p231.

Full text
Abstract:
Os adesivos autocondicionantes foram criados a fim de melhorar a performance clínica dos sistemas adesivos convencionais de condicionamento total e conferir técnica simplificada, com diferencial de adição de monômeros ácidos às soluções de primer/ adesivo que permitem condicionamento dos substratos dentais sem a remoção da smear layer. O objetivo desta revisão de literatura é avaliar as propriedades de resistência adesiva e longevidade desses materiais em relação aos sistemas adesivos convencionais. Para a seleção dos artigos foi realizada uma busca online nas bases bibliográficas PubMed e Scopus no período de 2007 a 2017, utilizando os descritores “self-etching adhesives”, “self-etching primers” e “bond strength” em combinação, sendo encontrados 330 artigos. Foram utilizados como critérios de inclusão publicações na língua inglesa de estudos laboratoriais e clínicos de intervenção em humanos. Foram excluídas pesquisas com período de avaliação inferior a 12 meses. Após refinamento da pesquisa, 20 estudos foram considerados válidos para essa revisão. Observou-se que os adesivos autocondicionantes exibem infiltração do adesivo concomitante com a desmineralização do substrato, fator que poderia reduzir o tempo de trabalho, a sensibilidade pós-operatória e reduzir a dificuldade de obtenção da umidade ideal para a qualidade do procedimento adesivo. Entretanto, notou-se que esses materiais apresentam-se muito hidrofílicos, o que reduz propriedades como resistência adesiva a médio e longo prazo, sobretudo, os materiais disponíveis em frasco único.Palavras-chave: Self-Etching. Adhesives.
APA, Harvard, Vancouver, ISO, and other styles
2

Brauner, K. V., C. P. Isolan, J. S. Ribeiro, M. S. Cenci, and R. R. Moraes. "Resistência de União de Adesivos Contemporâneos à Dentina Sadia e Afetada Por Cárie." Journal of Health Sciences 19, no. 5 (February 23, 2018): 163. http://dx.doi.org/10.17921/2447-8938.2017v19n5p163.

Full text
Abstract:
O objetivo deste estudo foi avaliar a resistência de união (RU) de adesivos contemporâneos à dentina sadia e afetada por cárie. Biofilmes de microcosmos originados de saliva humana foram formados sobre discos de dentina e cultivados em anaerobiose por 14 dias para simulação de cárie. Quatro adesivos foram aplicados (Single Bond Universal Ambar Universal Clearfil SE Bond e ADHE- SE) em dentina bovina hígida e cariada. Dois cilindros de resina composta (Filtek Z-350) foram confeccionados na superfície. Os cilindros foram submetidos ao teste de cisalhamento após 24h em uma máquina Universal de Ensaios. Para cada adesivo foi mensurado de pH através de um pHmetro calibrado para medir a acidez de cada frasco. Por fim, o GC foi mensurado usando-se espectroscopia de infravermelho por Transformada de Fourier. Os dados foram analisados por ANOVA e Mann Whitney (5%). Clearfil SE Bond apresentou maiores valores de RU independente do substrato quando comparado aos outros adesivos. (p<0,05). A dentina cariada diminuiu significativamente a RU dos adesivos, com exceção do Ambar que se manteve igual estatisticamente em ambos os substratos (p0,284), falhas adesivas predominaram. Quando analisado pH, o ADHE-SE se mostrou o mais e o Single Bond o menos ácido, já para o GC o ADHE-SE foi o que apresentou menores valores, enquanto o Ambar foi o que mais converteu. Conclui-se que o substrato cariado pode prejudicar a RU à dentina e que o adesivo Clearfil SE Bond parece se comportar melhor quando comparado aos outros adesivos do estudo.Palavras-chave: Resistência ao Cisalhamento. Cárie Dental. Adesivos Autocondicionantes.
APA, Harvard, Vancouver, ISO, and other styles
3

Froehlich, Laís, Marlon Rosin, Nicolas Mazur, Bruna Sampaio Boffo, Henrique Pezzini de Oliveira, Carine Zanchin, Tito Pires Terres Neto, Rolando Plümer Pezzini, Fabiana Scarparo Naufel, and Eduardo Benassi dos Santos. "Sistemas adesivos: uma revisão da literatura." Research, Society and Development 10, no. 2 (February 19, 2021): e36510212612. http://dx.doi.org/10.33448/rsd-v10i2.12612.

Full text
Abstract:
Os sistemas adesivos são responsáveis por promover a união entre o substrato dental e a restauração propriamente dita. Desde Buonocore, estes materiais sofreram importantes transformações. Diante disso, o presente estudo tem por objetivo revisar a literatura sobre as classificações, principais características e ação dos sistemas adesivos atuais. Trata-se de um estudo descritivo qualitativo, realizado através de um levantamento bibliográfico de artigos científicos publicados nos últimos 11 anos. Os sistemas adesivos convencionais são considerados complexos na pratica clínica. Já os autocondicionantes apresentam maior facilidade de aplicação que o anterior e boa adesão quando realizado o condicionamento ácido seletivo do esmalte. Enquanto isso, os adesivos universais apresentam uma composição mais complexa com a mistura de monômeros hidrófilos e hidrofóbicos que promovem adesão química ao dente. Quanto aos adesivos autocondicionantes de etapa única, a dupla aplicação da camada de adesivo pode melhorar a força e a qualidade da adesão. O adesivo universal possui potencial de ligação química como um benefício adicional, que depende de alguns monômeros funcionais. Dentre eles, o mais notável é o 10-metacriloiloxidecil-di-hidrogênio (10-MDP ou MDP), um monômero de fosfato que se liga ionicamente à dentina. Os adesivos universais demonstram bons resultados de resistência de união em dentina já condicionada ou não. Sem ataque ácido seletivo, os adesivos autocondicionantes são inferiores aos convencionais, já em esmalte preparado, ambos são equivalentes. Atualmente é possivel selecionar o melhor sistema adesivo para cada realidade clínica, atingindo bons resultados mesmo quando se tem limitações de tempo ou de recursos em seu local de trabalho.
APA, Harvard, Vancouver, ISO, and other styles
4

Bauer, José Roberto De Oliveira, Waldyr Romão Junior, Milton Masuda, Marcelo Mendes Pinto, Alberto Sansiviero, and Carlos Alberto Tavares. "Efeito de restaurações temporárias OZE na resistência de união ao microcisalhamento de sistemas adesivos à dentina." ConScientiae Saúde 7, no. 2 (November 26, 2008): 181–90. http://dx.doi.org/10.5585/conssaude.v7i2.1218.

Full text
Abstract:
O objetivo, neste estudo, foi avaliar o efeito do óxido de zinco e eugenol (OZE) usado como restaurador provisório na resistência de união ao microcisalhamento de adesivos. Os canais de 36 molares foram removidos, e a coroa dental, transversalmente seccionada em duas partes. A metade dos espécimes foi armazenada, enquanto a outra, restaurada com um restaurador temporário. Após 24 horas, a restauração OZE foi removida mecanicamente. As superfícies da dentina foram tratadas com os seguintes adesivos: Single Bond (SB), Clearfil SE (CSEB) e iBond (iB). Cinco cilindros de resina Z250 foram construídos em cada superfície de dentina. Depois de 24 horas de armazenamento os espécimes foram testados. O teste “t” de Student foi aplicado em cada sistema adesivo para avaliar a influência do eugenol nos valores de resistência de união (=5%). O cimento OZE usado como restaurador provisório não afeta os valores de resistência de união do adesivo convencional (SB), porém reduz a resistência de união dos sistemas adesivos autocondicionantes (iBond).
APA, Harvard, Vancouver, ISO, and other styles
5

Edson Alves CAMPOS, José Roberto Cury SAAD, Sizenando Toledo PORTO NETO, Lucas Arrais CAMPOS, and Marcelo Ferrarezi ANDRADE. "Efeito da inserção tardia de resina composta sobre a resistência de união de sistemas adesivos convencionais." RSBO 6, no. 4 (December 22, 2010): 375–80. http://dx.doi.org/10.21726/rsbo.v6i4.1239.

Full text
Abstract:
Introdução: Sistemas adesivos convencionais são caracterizados pelo condicionamento ácido da estrutura dental previamente à aplicação dos monômeros. Esses materiais podem ser classificados em 3 passos (quando primer e adesivo se encontram em frascos separados) ou 2 passos (em que a função de primer e adesivo é desempenhada por um único material). Objetivo: Verificar a influência do momento da inserção do material restaurador (inserção imediata ou tardia) sobre os valores de resistência de união de adesivos convencionais de 2 e 3 passos por meio do teste de microtração. Material e métodos: Foram utilizados dentes incisivos bovinos que tiveram sua superfície vestibular desgastada até se obter uma superfície plana em dentina. Empregaram-se sistemas adesivos convencionais de 3 passos (Scotchbond Multi-Uso – SMP; Optibond FL – OFL; Bond-It – BIT) e de 2 passos (Single-Bond – SB; Optibond Solo Plus – OSP; Bond-1 – B1), e resina composta (Z-350) foi aderida a esse substrato em dois diferentes momentos: imediata e tardiamente (após 24 horas). Todos os procedimentos foram realizados com simulação da pressão pulpar fisiológica. Os resultados foram submetidos à análise estatística Anova e ao teste de Tukey (p < 0,05). Resultados: Para inserção imediata da resina composta, todos os adesivos apresentaram comportamentos semelhantes. Os sistemas adesivos de 3 passos não evidenciaram redução da resistência de união quando a resina composta foi inserida tardiamente. Já os sistemas adesivos de 2 passos tiveram sensível redução dos valores de resistência de união. A redução ficou em torno de 30,24% para SB, 27,19% para OSP e 28,21% para B1. Conclusão: Cuidado especial deve ser tomado durante o uso de sistemas adesivos convencionais de 2 passos. É aconselhável que a resina composta seja inserida e polimerizada imediatamente após a conclusão do procedimento adesivo.
APA, Harvard, Vancouver, ISO, and other styles
6

Teixeira, G. S., L. Miotti, D. Z. Righes, P. H. Z. Fiori, and A. H. Susin. "Sistemas Adesivos Universais: a Influência da Condição do Substrato na Resistência de União em Dentina Erodida e Abrasionada." Journal of Health Sciences 19, no. 5 (February 23, 2018): 86. http://dx.doi.org/10.17921/2447-8938.2017v19n5p86.

Full text
Abstract:
Esse estudo avaliou a resistência de união (RU) imediata de diferentes sistemas adesivos universais aplicados sob diferentes estratégias em dentina hígida (HIG), erodida (ERO) e abrasionada (ABR). 72 terceiros molares foram divididos em 3 grupos (n24): HIG, ERO, ERO/ABR. Cada grupo foi subdivido conforme o sistema adesivo e o protocolo (n6): Single Bond Universal Self- etch (SBUSE), Single Bond Universal Total-etch (SBUTE), AllBond Universal Self-etch (ABSE) e AllBond Universal Total-etch (ABTE). O protocolo erosivo realizou-se através de ciclagem em refrigerante de cola por 7 dias. O grupo ERO/ABR seguiu os mesmos passos do grupo ERO, acrescido de um protocolo de escovação com dentifrício e saliva artificial, por 2 minutos. Após, os dentes receberam a aplicação dos sistemas adesivos, foram restaurados com resina composta e armazenados em água. Os dentes foram seccionados em forma de “palitos” (0,85mm2) e submetidos à microtração. ANOVA de dois fatores (a 0,05) foi feita para testar efeito e interação de cada um dos fatores e Teste de Tukey para confrontos intergrupos. Os fatores substrato (p0,001) e interação substrato/adesivo (p0,03) foram significantes, mas o fator adesivo não (p0,86). No confronto intergrupos verificou-se que dentina ERO não obteve diferenças estatísticas e atingiu os maiores resultados. O grupo HIG do ABSE e o grupo ERO/ABR do SBUSE apresentaram os piores resultados. Em geral, ABTE exibiu os melhores valores de RU. Concluiu-se que a estratégia TE e a dentina ERO, para ambos os sistemas adesivos, obtiveram os melhores resultados.Palavras-chave: Dentina, Adesivos, Erosão dental.
APA, Harvard, Vancouver, ISO, and other styles
7

Teixeira, R. R., CG Silva, A. K. B. Sousa, J. S. Mendonça, J. C. Silva, and T. A. Mendes. "A Influência do Uso de Agentes Antioxidantes na Resistência de União em Dentes Clareados: uma Revisão de Literatura." Journal of Health Sciences 19, no. 5 (February 23, 2018): 32. http://dx.doi.org/10.17921/2447-8938.2017v19n5p32.

Full text
Abstract:
O objetivo do presente estudo é revisar a literatura para avaliar a influência do uso de agentes antioxidantes na resistência de união em dentes clareados e restaurados imediatamente. Realizou-se uma busca bibliográfica na qual foram selecionados artigos do período de 2012 a 2017, nas bases de dados: PubMed, Bireme e Science Direct, no idioma inglês, utilizando os seguintes descritores: Dental Whitening, Antioxidant e Ascorbate. Sendo encontrados um total de 20 artigos, 10 desses são estudos laboratoriais, 7 são estudos clínicos e 3 revisões de literatura. Através de uma leitura criteriosa de títulos e resumos selecionou-se 10 artigos, de acordo com a relevância do tema, sendo excluídas revisões de literatura, bem como os artigos que fugiam da temática. No clareamento dental ocorrem reações de oxidação, os agentes clareadores liberam oxigênio e radicais com função oxidativa e é essa forte liberação de oxigênio que prejudica a resistência das ligações adesivas estabelecidas na interface dente/material restaurador. Esse oxigênio irá interferir a polimerização do adesivo e da resina, impossibilitando a restauração imediata. Uma variedade de antioxidantes é pesquisada com finalidade de aumentar a resistência de união de dentes clareados, dentre eles o ascorbato de sódio, destacou- se por se mostrar capaz de remover o peróxido de oxigênio residual, de modo a neutralizar os radicais livres remanescentes e possibilitar restituição da capacidade adesiva e de polimerização. A continuidade e o aprofundamento dos estudos sobre a eficácia e aplicabilidade dos antioxidantes são de suma importância para a comunidade científica e cirurgiões-dentistas em geral para que obtenha-se resultados cada vez mais satisfatórios.Palavras-chave: PubMed. Bireme. Science Direct.
APA, Harvard, Vancouver, ISO, and other styles
8

Cruz, S. M. L., N. Guimarães, J. S. Mendonça, S. L. Santiago, and V. P. Feitosa. "Efeitos da Incorporação de Agentes de Biomodificação em Adesivo Convencional na Variação de Módulo e Peso da Dentina Desmineralizada." Journal of Health Sciences 19, no. 5 (February 23, 2018): 186. http://dx.doi.org/10.17921/2447-8938.2017v19n5p186.

Full text
Abstract:
O objetivo do estudo foi avaliar o potencial biomodificador dentinário de diferentes agentes naturais incorporados ao sistema adesivo OptiBond S (OB) e seu efeito no grau de conversão (GC). Testou-se o líquido da casca da castanha de caju (LCC), seus constituintes purificados (Cardol e Cardanol) e proantocianidinas (PAC) do extrato da semente de uva por meio da alteração de massa (OM) e determinação do módulo de elasticidade (ME) de barras de dentina desmineralizadas. O GC dos adesivos foi avaliado por espectroscopia Raman. Quatro adesivos (LCC, cardol, cardanol e PAC) foram preparados com 1% em peso dos agentes. O grupo controle foi OB puro. Barras de dentina (1,5x1,0x6,0 mm) foram cortadas de molares humanos hígidos e completamente desmineralizadas. Barras com as mesmas medidas foram confeccionadas com os adesivos e justapostas às de dentina, fixadas com fio dental e armazenadas em água destilada por até 4 semanas, sendo o ME (máquina de ensaio universal) e o peso (balança de precisão) da dentina mensurados após 1 e 4 semanas. Para análise estatística foi utilizado análise de variância e teste de comparações individuais (P<0,05). Com relação a OM e GC, diferenças significantes foram identificadas, tendo o LCC (-6,41%) apresentado o melhor resultado de OM e o controle (-28,42%) o pior. Cardanol (85.3%) e controle (73,8%) mostraram os maiores GC e PAC (48,8%) o pior. Para o ME não houve diferenças significantes. Nas condições do estudo o LCC apresentou maior potencial biomodificador quando incorporado ao adesivo, contribuindo para menor degradação do colágeno.Palavras-chave: Colágeno. Módulo de Elasticidade. Biodegradação.
APA, Harvard, Vancouver, ISO, and other styles
9

Minto, André Marcelo Peruchi, Welingtom Dinelli, Tomio Nonaka, and Luis Henrique de Camargo Thomé. "Estudo comparativo da resistência à fratura de pré-molares superiores íntegros e restaurados com amálgama aderido." Pesquisa Odontológica Brasileira 16, no. 2 (June 2002): 121–26. http://dx.doi.org/10.1590/s1517-74912002000200005.

Full text
Abstract:
No presente estudo avaliou-se, in vitro, a resistência à fratura de pré-molares superiores preparados com cavidades de classe II compostas (conservadoras e extensas) restauradas com amálgama aderido a dois tipos diferentes de sistemas adesivos. Setenta dentes foram divididos em 4 grupos: grupo 1 ou controle com 10 dentes íntegros; grupo 2 com 20 dentes, sendo 10 cavidades conservadoras e 10 extensas restauradas com amálgama sem qualquer tipo de forramento. O grupo 3 e o grupo 4 foram compostos da mesma forma que o grupo 2, sendo que o primeiro recebeu cimento de ionômero de vidro (Vitrebond - 3M) e o segundo, adesivo dental (Scotchbond Multi-Purpose Plus - 3M), antes de serem restaurados. Os dentes haviam sido incluídos anteriormente em cilindros de PVC e fixados com resina acrílica. Após serem restaurados e termociclados, foram submetidos à fratura por força de compressão em uma máquina universal de testes EMIC-MEM 2000. Após análise de variância e aplicação do teste complementar de Tukey, concluiu-se que os sistemas adesivos utilizados condicionaram o aumento da resistência à fratura da estrutura dental nas cavidades convencionais, sendo os dentes com cavidades conservadoras mais resistentes em qualquer condição experimental.
APA, Harvard, Vancouver, ISO, and other styles
10

Coutinho, Emerson Felipe. "Reabilitação Estética em Dentes Anteriores Permanentes Traumatizados." Journal of Health Sciences 18, no. 3 (October 6, 2016): 195. http://dx.doi.org/10.17921/2447-8938.2016v18n3p195-200.

Full text
Abstract:
A estética dental é considerada um fator importante de inclusão social para a maioria das pessoas. Esta também influência no comportamento social e autoestima das crianças, pois muitas demonstram insegurança ao sorrirem, brincarem ou socializarem-se. A perda de parte da estrutura dentária compromete significantemente a vida desta criança. Dentre as fraturas dentais 96% acometem os incisivos centrais superiores permanentes, a maioria destes traumatismos acontecem na infância, 13% incluem crianças menores de 12 anos. O presente trabalho tem como objetivo relatar o caso de uma criança de 7 anos de idade, que sofreu um traumatismo nos elementos 11 e 21, com grande perda dos ângulos mesio-incisais das estruturas dentárias e sem comprometimento pulpar. Baseado na idade do paciente e na preocupação em preservar os elementos dentários, o tratamento de escolha para o caso foram restaurações adesivas diretas, estas foram confeccionadas com resina nanohíbrida, IPS Empress Direct (Ivoclar, Vivadent Ltda.). Este material é considerado de excelente padrão estético, possui translucência, fluorescência, textura e brilho superfície semelhantes aos da estrutura perdida. A reconstrução dentária através de restauração adesiva direta de Incisivos Centrais Superiores apesar de ser considerada um grande desafio para o profissional, é capaz de mimetizar os dentes naturais do paciente, restabelecendo a estética dental e do sorriso de forma natural, devolvendo as corretas funções dos dentes, tanto na mastigação como na fonação do paciente.
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Adesivi dentali"

1

Melo, Renata Marques de [UNESP]. "Efeitos do tipo de sistema adesivo e região do dente sobre a resistência adesiva à dentina." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/113977.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-06-13Bitstream added on 2015-01-26T13:30:28Z : No. of bitstreams: 1 000326687.pdf: 2821504 bytes, checksum: 1d66d1ded90d9d6ea873a9687a44bde1 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Este estudo foi realizado no intuito de avaliar a resistência de união à dentina coronária e do canal radicular com dois sistemas adesivos de condicionamento total (dois e três passos) e um sistema autocondicionante. Os canais de trinta incisivos e caninos humanos superiores foram instrumentados e preparados com brocas. Os pinos usados na cimentação foram réplicas em cimento resinoso dual Duo-link do pino Aestheti Plus #2. Assim, constituíram-se três grupos (n = 10), segundo o sistema adesivo utilizado: condicionamento total três passos (CT3) - AII-Bond 2 + pino em cimento resinoso (pcr)+ Duo-link (DI); condicionamento total 2 passos (CT2) - One-Step Plus + pcr + DI; autocondicionante (AC) - Tyrian/One-Step Plus+ pcr + DI. Apôs a cimentação, foram obtidas oito secções transversais (1,5mm), a partir de 4mm acima da JEC até 4mm aquém do ápice do canal, envolvendo dentina coronária e radicular. As secções foram submetidas ao ensaio de push-out em máquina de ensaio universal EMIC (1 mm.min-1). Os dados de resistêncía adesiva foram analisados com o teste ANOVA de dois fatores de medidas repetidas (α<0,05). Foi observado que o efeito interação foi estatisticamente significante, isto é, o relacionamento entre os adesivos não foi o mesmo para as diferentes regiões. Comparando-se as médias obtidas com os adesivos em cada região (Tukey; α<0,05), observou-se que o CT3 (média± desvio padrão: 5,22 ± 1,70) foi superior ao CT2 (2,60 ± 1,74) e ao AC (1,68 ± 1,85). Para as condições estudadas, obteve-se melhor adesão à dentina com a utilização do sistema adesivo de condicionamento total com três passos, sobretudo na região coronária
This study aimed to evaluate lhe bond strengths between two total etching adhesive systems and (two and three steps) anda self-etching system to coronal and root canal dentin. The root canal of thirty human anterior teeth were endodontically instrumented and prepared with specific burs. Aestheti Plus #2 posts were duplicated in dual resin cement (Duo-link) and three groups (n=10) were formed, according to the adhesive sysfem used: 3 steps total etching adhesive system (3TE) - All-Bond 2 + resin cement post (rcp) + Duo-link (DI); 2 steps total etching adhesive system (2TE) - One-Step Plus + rcp + DI; sef-etching system (SE) Tyrian/One-Step Plus + rcp +DI. Following cementation, the teeth were cut transversally in eight sections (1,5mm), from the CEJ to 4mm above the canal apex. The sections were subjected to the push-out test in a universal testing machine (1mm.min-1). The data of bond strength were statistically analyzed with 2-way Anova of repeated measures (α<0.05), which showed that the interaction effect was significant. This meant that the relationship between the adhesives was not the same depending on the tooth region. Regarding the adhesive factor'' the comparison of means with Tukey test (α<0.05) showed that 3TE (mean ± standard deviation: 5,22 ± 1,70) was statistically superior to 2TE (2,60 ± 1,74) and SE (1,68 ± 1,85). Under the conditions of the present study, the three step total etching system had the highest bond strengths to dentin, especially in the coronal region
APA, Harvard, Vancouver, ISO, and other styles
2

Gonçalves, Sérgio Eduardo de Paiva [UNESP]. "Adesivos multi-uso-avaliação da resistência adesiva a dentina frente a teste de cisalhamento, estereomicroscopia e microscopia eletrônica de varredura." Universidade Estadual Paulista (UNESP), 1994. http://hdl.handle.net/11449/131859.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:22:16Z (GMT). No. of bitstreams: 0 Previous issue date: 1994-12-15. Added 1 bitstream(s) on 2015-12-10T14:28:20Z : No. of bitstreams: 1 000023950.pdf: 5255881 bytes, checksum: a5b00e9d9a2096ed77f9f420143ca8d6 (MD5)
Adesão tem sido a meta das pesquisas Odontológicas nas últimas décadas. Para determinar se os mais recentes sistemas adesivos denominados como MULTI-USO poderiam ser utilizados associados a diferentes marcas comerciais de resina composta, em dentina, foram realizados testes de resistência ao cisalhamento. Setenta e dois corpos de prova foram confeccionados utilizando-se dentes pré-molares humanos íntegros, embutidos em resina acrílica, expondo-se a dentina por tratamento com lixas d'água de granulações 180, 400 e 600. Os corpos de prova foram divididos em três grupos: Grupo 1 Scotchbond Multi-Purpose (3M), grupo 2 - Optibond Light Cure (Kerr) e grupo 3 - Optibond Dual Cure (Kerr). Todos os grupos foram subdivididos em sub-grupos de 8 dentes, nos quais foram inseridas as resinas compostas: a-Z1 00 (3M do Brasil), bPrisma APH (Dentsply) e c- Herculite XRV(Kerr). Os corpos de prova foram submetidos à ciclagem térmica e após 24 horas de armazenamento em água destilada 370C, aos testes de resistência ao cisalhamento em máquina lnstron 4301 seguidos de análise em estereomicroscópio Technivai-Carl Zeiss de aumento para avaliar o tipo de fratura e, análise em microscopia eletrônica de varredura (M.E.V.). A aplicação do modelo estatístico de análise de variância permitiu a constatação de que o fator Adesivo apresentou um valor significante (p<0,05) independente do fator Resina, tendo o adesivo Optibond Light Cure propiciado a maior resistência média ao cisalhamento (15,446 MPa), seguido do Scotchbond Multi-Purpose (13,340 MPa) e do Optibond Dual Cure (1 0,019 MPa). A interaçâo Adesivo x Resina apresentou um valor estatisticamente significante (p<0,05), onde os melhores resultados foram obtidos entre as resinas Z100 e Herculite XRV com o adesivo Optibond Light Cure, e entre a Resina APH com o adesivo Scotchbond Multi-Purpose. Concluímos que o adesivo Optibond...
Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose
APA, Harvard, Vancouver, ISO, and other styles
3

Melo, Renata Marques de. "Efeitos do tipo de sistema adesivo e região do dente sobre a resistência adesiva à dentina /." São José dos Campos, 2005. http://hdl.handle.net/11449/113977.

Full text
Abstract:
Orientador: Carlos Augusto Pavanelli
Banca: Paulo Sérgio Mutarelli
Banca: Carlos Rocha Gomes Torres
Resumo: Este estudo foi realizado no intuito de avaliar a resistência de união à dentina coronária e do canal radicular com dois sistemas adesivos de condicionamento total (dois e três passos) e um sistema autocondicionante. Os canais de trinta incisivos e caninos humanos superiores foram instrumentados e preparados com brocas. Os pinos usados na cimentação foram réplicas em cimento resinoso dual Duo-link do pino Aestheti Plus #2. Assim, constituíram-se três grupos (n = 10), segundo o sistema adesivo utilizado: condicionamento total três passos (CT3) - AII-Bond 2 + pino em cimento resinoso (pcr)+ Duo-link (DI); condicionamento total 2 passos (CT2) - One-Step Plus + pcr + DI; autocondicionante (AC) - Tyrian/One-Step Plus+ pcr + DI. Apôs a cimentação, foram obtidas oito secções transversais (1,5mm), a partir de 4mm acima da JEC até 4mm aquém do ápice do canal, envolvendo dentina coronária e radicular. As secções foram submetidas ao ensaio de push-out em máquina de ensaio universal EMIC (1 mm.min-1). Os dados de resistêncía adesiva foram analisados com o teste ANOVA de dois fatores de medidas repetidas (α<0,05). Foi observado que o efeito interação foi estatisticamente significante, isto é, o relacionamento entre os adesivos não foi o mesmo para as diferentes regiões. Comparando-se as médias obtidas com os adesivos em cada região (Tukey; α<0,05), observou-se que o CT3 (média± desvio padrão: 5,22 ± 1,70) foi superior ao CT2 (2,60 ± 1,74) e ao AC (1,68 ± 1,85). Para as condições estudadas, obteve-se melhor adesão à dentina com a utilização do sistema adesivo de condicionamento total com três passos, sobretudo na região coronária
Abstract: This study aimed to evaluate lhe bond strengths between two total etching adhesive systems and (two and three steps) anda self-etching system to coronal and root canal dentin. The root canal of thirty human anterior teeth were endodontically instrumented and prepared with specific burs. Aestheti Plus #2 posts were duplicated in dual resin cement (Duo-link) and three groups (n=10) were formed, according to the adhesive sysfem used: 3 steps total etching adhesive system (3TE) - All-Bond 2 + resin cement post (rcp) + Duo-link (DI); 2 steps total etching adhesive system (2TE) - One-Step Plus + rcp + DI; sef-etching system (SE) Tyrian/One-Step Plus + rcp +DI. Following cementation, the teeth were cut transversally in eight sections (1,5mm), from the CEJ to 4mm above the canal apex. The sections were subjected to the push-out test in a universal testing machine (1mm.min-1). The data of bond strength were statistically analyzed with 2-way Anova of repeated measures (α<0.05), which showed that the interaction effect was significant. This meant that the relationship between the adhesives was not the same depending on the tooth region. Regarding the "adhesive factor'' the comparison of means with Tukey test (α<0.05) showed that 3TE (mean ± standard deviation: 5,22 ± 1,70) was statistically superior to 2TE (2,60 ± 1,74) and SE (1,68 ± 1,85). Under the conditions of the present study, the three step total etching system had the highest bond strengths to dentin, especially in the coronal region
Mestre
APA, Harvard, Vancouver, ISO, and other styles
4

Vincenzi, Bárbara. "Efeito do condicionamento ácido e do envelhecimento na resistência da união adesiva de um adesivo universal ao esmalte dental." Universidade Estadual do Oeste do Paraná, 2018. http://tede.unioeste.br/handle/tede/3963.

Full text
Abstract:
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-10-03T14:30:06Z No. of bitstreams: 2 Bárbara_Vincenzi2018.pdf: 1279106 bytes, checksum: d44d41a7b8387c799cad466834f2786c (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Made available in DSpace on 2018-10-03T14:30:06Z (GMT). No. of bitstreams: 2 Bárbara_Vincenzi2018.pdf: 1279106 bytes, checksum: d44d41a7b8387c799cad466834f2786c (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-28
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
Purpose: To evaluate the performance of an universal restorative adhesive system (total- and self-etching mode) on bond strength (BS) to the enamel immediately and after 12 months. Materials and methods: Eleven human third molars were sectioned in half to obtain twenty-two samples. The proximal enamel surfaces were planned, polished and randomly divided into 2 groups according to the treatment, and these subdivided (2 groups) according to the storage time, making 4 groups (n = 11): CAI (Scotchbond Universal adhesive-SBU, with prior 37% phosphoric acid conditioning for 15 sec, analyzed immediately); CA12m (same treatment as CAI, analyzed after 12 months aging); SAI group (SBU without prior acid conditioning, analyzed immediately); SA12m (same treatment as SAI, analyzed after 12 months aging). All samples were restored with Scothbond Universal adhesive (SBU) and Filtek Z100 composite resin according to the manufacturer's instructions. The composite resin blocks were built up incrementally. The specimens were stored in deionized for 24 hours and sectioned in sticks (1.0 ± 0.2 mm area) and subjected to microtensile on test machine on 0.5mm/min immediately (24h) and after 12 months . Data were submitted to ANOVA two criteria (p <0.01) followed by the Tukey post-test (p<0.05). Results: Enamel acid etching promoted a significant increase in RU values after immediate traction. However, after 12 months, RU values decreased significantly, with no statistical difference between the groups with and without acid conditioning. Conclusions: Enamel conditioning increased the immediate bond strength of the universal adhesive, and aging after 12 months reduced it.
Objetivos: Avaliar o desempenho de um sistema adesivo restaurador universal (modo convencional e autocondicionante) na resistência de união (RU) ao esmalte em período imediato e após 12 meses. Materiais e métodos: Onze terceiros molares humanos hígidos foram seccionados ao meio para obter vinte e duas amostras. As superfícies proximais do esmalte foram planificadas, polidas e aleatoriamente divididas em 2 grupos de acordo com o tratamento, e estes subdivididos (2 grupos) de acordo com o tempo de estocagem, perfazendo 4 grupos (n=11): CAI (adesivo Scotchbond Universal-SBU, prévio condicionamento com ácido fosfórico por 15 seg, análise imediata); CA12m (mesmo tratamento do CAI, análise após envelhecimento de 12 meses); SAI (adesivo SBU sem condicionamento ácido prévio, análise imediata); SA12m (mesmo tratamento do SAI, análise após 12 meses). Todas as amostras foram restauradas com o adesivo Scothbond Universal (SBU) e resina composta Filtek Z100 de acordo com as instruções do fabricante. Os blocos de resina composta foram construídos incrementalmente. Os espécimes foram armazenados em água destilada por 24h, e posteriormente seccionados em palitos (área 1,0 ± 0,2mm) que foram submetidos ao teste de microtração em máquina de teste a 0.5mm/min imediatamente (24h) e 12 meses após. Os dados foram submetidos a ANOVA dois critérios (p <0.01) seguido pelo pós-teste de Tukey (p<0,05). Resultados: O condicionamento ácido do esmalte promoveu aumento significativo dos valores de RU após tração imediata. No entanto, após 12 meses, os valores de RU diminuíram significativamente, sem diferença estatística entre os grupos com e sem condicionamento ácido. Conclusões: O condicionamento do esmalte aumentou a resistência de união adesiva do adesivo universal imediata, e o envelhecimento após 12 meses a reduziu.
APA, Harvard, Vancouver, ISO, and other styles
5

Legramandi, Debora Barrozo. "Resistência adesiva à dentina após clareamento dental." Universidade de São Paulo, 2005. http://www.teses.usp.br/teses/disponiveis/25/25131/tde-30092005-094942/.

Full text
Abstract:
Com a introdução de várias técnicas de clareamento dental, bem como o lançamento de vários agentes clareadores em diferentes concentrações e formas de ativação (química e física), se faz necessária a investigação de sua ação sobre as estruturas dentais. Assim, o objetivo desse estudo foi testar as hipóteses de que a técnica de clareamento dental com peróxido de hidrogênio a 35% (Whiteness HP) diminui a resistência adesiva à dentina dos sistemas adesivos convencionais contendo como solvente acetona (Prime & Bond NT) ou água e etanol (Single Bond) e do sistema adesivo autocondicionante (Clearfil SE Bond) e que após sete dias do clareamento os valores de resistência adesiva à dentina humana retornam aos valores dos dentes não submetidos a clareamento. Foram confeccionados 162 espécimes, divididos em 9 grupos: GRUPO 1- (controle) - sistema adesivo convencional Prime & Bond NT. GRUPO 2- (controle) - sistema adesivo convencional Single Bond; GRUPO 3- (controle) - sistema adesivo autocondicionante Clearfil SE Bond; GRUPO 4 - clareamento com Whiteness HP e adesão imediata com sistema adesivo convencional Prime & Bond NT; GRUPO 5 - clareamento com Whiteness HP e adesão imediata com sistema adesivo convencional Single Bond; GRUPO 6 - clareamento com Whiteness HP e adesão imediata com sistema adesivo autocondicionante Clearfil SE Bond; GRUPO 7 - clareamento com Whiteness HP; armazenamento em estufa a 37°C durante 7 dias e sistema adesivo Prime & Bond NT GRUPO 8 - clareamento dental com Whiteness HP; armazenamento em estufa a 37% durante 7 dias e sistema adesivo convencional Single Bond; GRUPO 9 - clareamento com Whiteness HP; armazenamento em estufa a 37% durante 7 dias e sistema adesivo autocondicionante Clearfil SE Bond. Todos os dentes foram restaurados com resina composta TPH e submetidos ao teste de microtração à velocidade de 1.0 mm/min em uma máquina de ensaios universal (Emic, Brasil). As médias e respectivos desvios - padrão para cada grupo foram: G1-25.73 ±3.84; G2- 24.26 ±3.78; G3- 30.95 ±5.02; G4- 23.81 ±6.68; G5- 23.60 ±5.88; G6-28.85 ±3.81; G7- 32.69 ± 8.06; G8- 25.86 ±6.16; G9- 27.45 ±8.97. Após análise estatística pelos testes ANOVA a um critério e Tukey , para comparações individuais, foi possível concluir que a técnica de clareamento dental com o peróxido de hidrogênio a 35% promoveu uma diminuição da resistência adesiva à dentina do sistema adesivo que apresenta acetona como solvente (Prime & Bond NT), sendo que os valores de resistência adesiva foram recuperados sete dias após o clareamento dental; a técnica de clareamento dental com o peróxido de hidrogênio a 35% não alterou a resistência adesiva à dentina do sistema adesivo que apresenta água e etanol como solvente (Single Bond) e para o sistema adesivo autocondicionante (Clearfil SE Bond).
The aim of this study was to evaluate the effect of a bleaching agent and the influence of delaying the bonding procedures on bond strength to human dentin using different adhesive systems. The first hypothesis to test was that the bleaching technique with 35% hydrogen peroxide (Whiteness HP) decreases the bond strength to dentin when two conventional adhesive systems (an acetone-based - Prime&Bond NT (PB); a water/ ethanol based - Single Bond (SB)) and a self- etching system (Clearfil SE Bond (SE) are applied. The second hypothesis was that there is no difference in bond strength values 7 days after bleaching. Thirty six specimens were prepared and divided into 9 groups: G1- PB (control), G2- SB (control); G3- SE (control), G4- Whiteness HP (HP) + immediate bonding procedure with PB, G5- HP + immediate bonding with SB, G6- HP + immediate bonding with SE, G7- HP + storage at 37oC for 7 days + PB, G8- HP + storage at 37o C for 7 days + SB, G9- HP + storage at 37oC for 7 days + SE. After bonding agent application, all teeth were restored with resin composite TPH and submitted to microtensile test in a Universal Testing Machine (Emic, Brazil) at a crosshead speed of 1mm/ min. Data were analyzed by ANOVA and Tukey tests (5%). The mean values (MPa) and standard deviation for each group was: G1- 25.73 ± 3.84; G2- 24.26 ± 3.78, G3- 30.95 ± 5.02, G4-23.81 ± 6.68, G5- 23.60 ± 5.88, G6- 28.85 ± 3.81, G7- 32.69 ± 8.06, G8- 25.86 ± 6.16, G9- 27.45 ± 8.97. It can be concluded that the bleaching technique using 35% hydrogen peroxide decreased the bond strength to dentin when acetonebased system (PB) was applied. However, the bond strength mean values were reversed 7 days after bleaching. There was no influence of 35% hydrogen peroxide bleaching treatment on bond strength when SB (water/ ethanol based) and SE (self- etching) were used.
APA, Harvard, Vancouver, ISO, and other styles
6

Deucher, Camila. "Avaliação da resistência adesiva de sistemas adesivos ao esmalte clareado de dentes bovinos sob teste de microtração." reponame:Repositório Institucional da UFSC, 2014. https://repositorio.ufsc.br/xmlui/handle/123456789/123285.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014.
Made available in DSpace on 2014-08-06T18:02:16Z (GMT). No. of bitstreams: 1 326596.pdf: 70286873 bytes, checksum: 1a3f6a5a37119122f45b0181d91a596e (MD5) Previous issue date: 2014
Objetivos: Este estudo teve como objetivo avaliar a resistência de união sob teste de microtração ao esmalte clareado utilizando diferentes sistemas adesivos após o tratamento clareador. Material e métodos: Para isso utilizou-se a face vestibular de 30 incisivos bovinos, que foram divididos em 6 grupos: em G1, G2 e G3 não submetidos ao clareamento e G4, G5 e G6 submetidos ao clareamento com peróxido de carbamida 10% (Power Bleaching, BM4) por 1 mês (2 h/dia). Em seguida os dentes foram restaurados com resina composta utilizando os seguintes sistemas adesivos: em G1 e G4 utilizou-se o adesivo Prime&Bond; enquanto em G2 e G5 Gluma2; já em G3 e G6 o adesivo Clearfill SE BOND, sendo escolhidos com base no solvente. Após 24 horas armazenados em água, obtiveram-se palitos (0,9 mm2) através de cortes seriais e transversais, e submetidos ao teste de microtração (0,5 mm/s). Resultados: A análise estatística demonstrou diferença significante da resistência de união entre o esmalte clareado e não clareado. Além disso, o adesivo Prime&Bond mostrou resistência de união média superior aos demais adesivos. A análise da interação entre o tratamento de superfície e o adesivo utilizado mostrou maior resistência adesiva em esmalte não clareado em Prime&Bond e Gluma2. Entretanto, Gluma2 obteve os valores mais baixos no esmalte clareado. Prime&Bond e Clearfill SE BOND apresentaram valores semelhantes em esmalte clareado, sendo que Clearfill SE BOND não obteve diferença quando comparado o esmalte clareado ao não clareado. Conclusão: O tratamento clareador influenciou negativamente a resistência adesiva à microtração, estando dependente do sistema adesivo utilizado.
APA, Harvard, Vancouver, ISO, and other styles
7

Esteves, Stella Renata Machado Silva. "Avaliação morfológica, físico-química e mecânica longitudinal de adesivo dental experimental manipulado com diferentes concentrações de água." Universidade Estadual Paulista (UNESP), 2018. http://hdl.handle.net/11449/153050.

Full text
Abstract:
Submitted by Stella Renata Machado Silva Esteves null (stellarmse@gmail.com) on 2018-03-15T12:49:21Z No. of bitstreams: 1 tese doutorado arquivo unico.pdf: 3856356 bytes, checksum: d346b9a5b9474275d35a835574475d08 (MD5)
Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-03-16T15:51:18Z (GMT) No. of bitstreams: 1 esteves_srms_dr_sjc.pdf: 3856356 bytes, checksum: d346b9a5b9474275d35a835574475d08 (MD5)
Made available in DSpace on 2018-03-16T15:51:18Z (GMT). No. of bitstreams: 1 esteves_srms_dr_sjc.pdf: 3856356 bytes, checksum: d346b9a5b9474275d35a835574475d08 (MD5) Previous issue date: 2018-02-02
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O objetivo desse estudo foi avaliar um adesivo experimental com diferentes concentrações de água, bem como sua degradação morfológica, química, física e mecânica. A primeira etapa envolveu a manipulação do adesivo experimental contendo 45/55% de HEMA e BisGMA, 0.5% de canforoquinona, 0.5% EDMAB e 1% de DPIHP. Foram incorporadas diferentes concentrações de água a partir dessa formulação adesiva (0, 10 e 16%). Os modelos adesivos foram fotopolimerizados e as análises iniciais realizadas: Morfológicas (Estereomicroscopio e Micro-xct); Físicas (Rugosidade-Ru, Sorção-Sor, Solubilidade-Sol); Químicas (Grau de conversão-GC, Mapeamento do espécime com 16% de água e os monômeros liberados pela CLAE); Mecânicas (Resistência flexural-RF, Módulo de elasticidade-ME e Resistência a compressão-RC). Em seguida os espécimes foram divididos conforme a solução de envelhecimento (água, etanol e acetona). Foram realizadas novas análises após o envelhecimento por 2 e 84 dias. Os testes estatísticos ANOVA e Tukey (5%) foram realizados. Os resultados iniciais, sem o envelhecimento, mostraram que as diferentes concentrações de água influenciam as propriedades dos adesivos. Na análise morfológica notou-se a presença de bolhas no espécime com 16% de água. Para a Ru e GC os maiores valores foram encontrados para os espécimes com mais água em sua composição e os menores para 0%. Já nas análises mecânicas, para RF e ME os espécimes com 10% de água foram mais resistentes; e em RC os espécimes com 16% foram menos resistentes. Após o envelhecimento notou-se trincas nos espécimes 0% e 16% na solução de acetona. Nos testes físicos, os espécimes com 16% absorveram mais solução; o etanol mostrou menores valores de solubilidade; Para Ru a água e a acetona diferiram em todas as concentrações e períodos, o mesmo ocorrendo para as concentrações 0 e 16%. Nos testes químicos o GC não foi alterado pelo envelhecimento. O mapeamento na amostra com 16% de água mostrou que inicialmente perto do poro o GC é menor e a quantidade de HEMA é maior; longe do poro a relação é inversa. Porém, após o envelhecimento, o GC próximo ao poro se tornou similar ao distante do poro. Através da CLAE observou-se uma maior liberação de componentes do espécime com 0% de água que os espécimes com 10% e 16%. Os testes mecânicos mostraram que o envelhecimento em acetona foi mais prejudicial que em água. Para a RF e ME os espécimes com 0% de água foram mais afetados que os espécimes com 10% e 16% em 2 e 84 dias. Para a RC após 2 dias o espécime com 16% foi mais afetado que 0 e 10%, no entanto, após 84 dias o espécime com 0% foi mais afetado pelo envelhecimento. Pode-se constatar que a quantidade de água e o tipo de envelhecimento afetam as propriedades dos sistemas adesivos baseados na composição 45/55% HEMA/BisGMA.
The aim of this study was evaluated an experimental adhesive with different water content, as well the degradation morphological, physical, chemical and mechanical. Firstly the dental adhesive was manipulated with 45/55% of HEMA and BisGMA, 0.5% of CQ, 0.5% EDMAB e 1% of DPIHP. Was added different water content (0, 10 and 16%). The adhesive model was cured and the analysis was done: Morphological (Stereomicroscope and Micro-xct); Physical (Surface Roughness), Sorption, Solubility); Chemical (Degree of convertion, Map of the pore on 16% water content sample and the released monomers- HPLC); Mechanicals (Flexural strength, Modulus of elasticity and Compressive strength). After the these analyzes, the samples were divided to each evaluation into 3 groups according to solution for performed ageing (water, ethanol and acetone). Further analyzes were performed after aging for 2 and 84 days. Statistical tests of ANOVA and Tukey (5%) were performed. Initial results, without aging, showed that the different water content influence adhesive properties. In the morphological analysis, bubbles were present on the sample with 16% water. For Ru and DC all specimens differed from each other, with the highest values for the specimens with 16% and the lowest to 0%. In the mechanical analyzes, for RF and ME the specimens with 10% water were more resistant; and in RC the specimens with 16% were less resistant. After aging it is possible notice cracks on the border of specimens 0% and 16% in the acetone. In the physical tests, the specimens with 16% absorbed more solution; ethanol showed lower values of solubility; For Ru, water and an acetone are differed in all concentrations and periods, the same for the concentration 0 and 16%. In the chemical tests DC was not altered by aging. The mapping in the sample with 16% of water showed that near to the pore the DC is smaller and a quantity of HEMA is larger; far from the pore this relation is inverse. However, after aging solutions, the DC near the pore became similar to the far from pore. Through HPLC was possible observed that release more components of the sample with 0% than 10% and 16%. The mechanical tests showed that the acetone damage more samples than water. For an RF and ME the specimens 0% were more affected than 10% and 16% after 2 and 84 days. For a RC after 2 days the sample with 16% was more affected than 0 and 10%, however, after 84 days the specimen with 0% was more affected by aging. It can be seen that the amount of water and the type of aging affect the adhesive properties of the database systems based on the 45/55% HEMA / BisGMA composition.
APA, Harvard, Vancouver, ISO, and other styles
8

Valeretto, Thiago Majolo. "Avaliação da influência de agentes químicos previamente à aplicação de sistemas adesivos autocondicionantes na resistência adesiva à dentina." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/25/25148/tde-23042014-095854/.

Full text
Abstract:
Com os sistemas adesivos autocondicionantes, o uso prévio do ácido fosfórico passou a ser dispensado em dentina. Assim, outras soluções foram propostas a fim de se promover uma limpeza da cavidade e otimizar um melhor embricamento do adesivo ao substrato. O objetivo deste estudo foi avaliar a influência de soluções químicas à adesão à dentina bovina, por meio da resistência ao microcisalhamento, de três sistemas adesivos autocondicionantes em função do tempo. Duzentos e quarenta incisivos bovinos foram incluídos, desgastados e polidos em série com lixas de carbeto de silício, obtendo uma superfície planificada de dentina de 10 mm de diâmetro. Os espécimes foram divididos aleatoriamente em 4 grupos, de acordo com a solução aplicada: SF- aplicação de soro fisiológico com 0,9% NaCl (grupo controle); HS- desproteinização com hipoclorito de sódio a 5%, por 2 minuto e HSAA- hipoclorito de sódio a 5%, por 2 minuto seguida da aplicação de ácido ascórbico (ascorbato) a 10%, por 1 minuto; CHX- aplicação de solução clorexidina a (2% por 1 minuto). Às superfícies preparadas foram aplicados três sistemas adesivos autocondicionantes, por grupo - Optibond All-in-One (KERR), Filtek P90-System Adhesive (3M-ESPE) e Adper SE (3M-ESPE), todas seguidas da inserção de resina composta (Filtek Z250 ou Filtek P90). Metade dos espécimes de cada grupo foram armazenados por 24 horas e metade por 6 meses. Após esses períodos, os espécimes foram submetidos ao teste de microcisalhamento, em uma máquina de ensaios universal (Emic, na velocidade de 0,5mm/min). Os dados foram avaliados estatisticamente através de análise de variância (ANOVA) a três critérios e testes de comparações múltiplas de Tukey ambos considerando a=0,05. O adesivo Filtek P90-System Adhesive foi o único que manteve a resistência adesiva após o envelhecimento, porém, os dois tratamentos de superfície contendo hipoclorito de sódio influenciaram negativamente. Já com a clorexidina não houve diferença estatisticamente significante comparada ao grupo controle. O adesivo OptiBond All- In-One (Kerr) foi influenciado positivamente pelo hipoclorito de sódio e hipoclorito de sódio mais ascorbato, no tempo de 24 horas. Sendo de iqual resultado com o envelhecimento em solução aquosa. Adper SE (3M-ESPE) sofreu influência dos tratamentos à base de hipoclorito de sódio. O melhor resultado, comparando dois tratamentos com hipoclorito, após o envelhecimento, foi obtido pelo tratamento com o hipoclorito de sódio mais ascorbato sendo estatisticamente idêntico ao grupo controle. Foi concluído que os tratamentos de superficie influenciam na resistência adesiva dos adesivos testados. A clorexidina possibilitou os melhores resultados em quase todos os testes.
With the Self-etching adhesives, acid-etching with phosphoric acid has to be dispensed in dentin. Than, other solutions have been proposed in order to promote the cavity cleaner and improvement in bonding effectiveness. The aim of this study was to investigate the microshear bond strength, with the influence of chemical solutions and time, in three adhesive systems used on bovine dentin. Two hundred and forty bovine incisors were included, and the surface was polished in series with silicon carbide paper, getting flattened dentin surface of 10 mm in diameter. The specimens were randomly divided into four groups, according to the applied solution: SF- saline solution with 0.9% NaCl (control group), HS-deproteinization with sodium hypochlorite at 5%, for 2 minutes and HSAA- sodium hypochlorite 5% for 2 minutes followed by the application of ascorbic acid (ascorbate) and 10% for 1 minute;CHXapplication of chlorhexidine solution (2% for 1 minute). Were applied to surfaces prepared three adhesive systems, per group - Optibond All-in-One (Kerr), Filtek-P90 System Adhesive (3M-ESPE) and Adper SE (3M-ESPE), all followed by the insertion of composite resin ( Filtek Z250 and Filtek P90). Half of the specimens of each group / treatment were stored for 24 hours and half for six months. After these periods were tested using the microshear in a universal testing machine (Emic, the speed of 0.5 mm / min). Results were submitted to three way ANOVA and TUKEY test multiple comparison both considering a = 0.05. The adhesive Filtek P90 System Adhesive was the one who kept the bond strength after aging, however, the two surface treatments containing sodium hypochlorite influenced negatively. With chlorhexidine, there was no statistically significant difference compared to the control group. The adhesive OptiBond All-in-One (Kerr) was affected by the sodium hypochlorite, sodium hypochlorite more ascorbate, at 24 hours. As a result of iqual with aging in aqueous solution. Adper SE (3M-ESPE) was influenced by the treatments using sodium hypochlorite. The best result, comparing two treatments with hypochlorite, after aging, was obtained by treatment with sodium hypochlorite more ascorbate was statistically identical to the control group. It was concluded that the influence of surface treatments on bond strength of adhesives tested. The chlorhexidine resulted in better results in almost every test.
APA, Harvard, Vancouver, ISO, and other styles
9

Gonçalves, Sérgio Eduardo de Paiva. "Adesivos multi-uso-avaliação da resistência adesiva a dentina frente a teste de cisalhamento, estereomicroscopia e microscopia eletrônica de varredura /." São Jose dos Campos, 1994. http://hdl.handle.net/11449/131859.

Full text
Abstract:
Orientador: Maria Amélia Máximo de Araújo
Banca: Dan Mihail Fichman
Banca: Rogerio Lacaz Neto
Resumo: Adesão tem sido a meta das pesquisas Odontológicas nas últimas décadas. Para determinar se os mais recentes sistemas adesivos denominados como MULTI-USO poderiam ser utilizados associados a diferentes marcas comerciais de resina composta, em dentina, foram realizados testes de resistência ao cisalhamento. Setenta e dois corpos de prova foram confeccionados utilizando-se dentes pré-molares humanos íntegros, embutidos em resina acrílica, expondo-se a dentina por tratamento com lixas d'água de granulações 180, 400 e 600. Os corpos de prova foram divididos em três grupos: Grupo 1 Scotchbond Multi-Purpose (3M), grupo 2 - Optibond Light Cure (Kerr) e grupo 3 - Optibond Dual Cure (Kerr). Todos os grupos foram subdivididos em sub-grupos de 8 dentes, nos quais foram inseridas as resinas compostas: a-Z1 00 (3M do Brasil), bPrisma APH (Dentsply) e c- Herculite XRV(Kerr). Os corpos de prova foram submetidos à ciclagem térmica e após 24 horas de armazenamento em água destilada 370C, aos testes de resistência ao cisalhamento em máquina lnstron 4301 seguidos de análise em estereomicroscópio Technivai-Carl Zeiss de aumento para avaliar o tipo de fratura e, análise em microscopia eletrônica de varredura (M.E.V.). A aplicação do modelo estatístico de análise de variância permitiu a constatação de que o fator Adesivo apresentou um valor significante (p<0,05) independente do fator Resina, tendo o adesivo Optibond Light Cure propiciado a maior resistência média ao cisalhamento (15,446 MPa), seguido do Scotchbond Multi-Purpose (13,340 MPa) e do Optibond Dual Cure (1 0,019 MPa). A interaçâo Adesivo x Resina apresentou um valor estatisticamente significante (p<0,05), onde os melhores resultados foram obtidos entre as resinas Z100 e Herculite XRV com o adesivo Optibond Light Cure, e entre a Resina APH com o adesivo Scotchbond Multi-Purpose. Concluímos que o adesivo Optibond...
Abstract: Recent bonding systems have been advocated as "multi-purpose bonding agents". The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose
Mestre
APA, Harvard, Vancouver, ISO, and other styles
10

Pinhão, Marcelo José Braga. "Análise molecular vibracional da interface adesivo-dentina após aplicação de múltiplas camadas de sistemas adesivos convencionais de dois passos." Universidade do Estado do Rio de Janeiro, 2008. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=3488.

Full text
Abstract:
O propósito do presente estudo foi analisar o efeito da aplicação de múltiplas camadas consecutivas de dois sistemas adesivos convencionais de dois passos na difusão resinosa e padrão de distribuição dos componentes monoméricos resinosos. Dezesseis terceiros molares humanos hígidos foram tratados com os sistemas adesivos convencionais de dois passos de acordo com as instruções dos fabricantes ou com aplicações em múltiplas camadas consecutivas. Os espécimes foram seccionados paralelamente aos túbulos dentinários e as superfícies submetidas ao polimento com lixas 600, 1200, 1800, 2000 e 4000. Os espectros Raman foram coletados ao longo de uma linha perpendicular a interface adesivo-resina em intervalos de 1 ou 2 m. As medidas de difusão da resina adesiva e distribuição dos componentes monomériccos foram avaliadas pelos picos Raman de 1113 cm-1, 1609 cm-1 e 1454 cm-1. O gradiente de desmineralização usado na determinação da região de hibridização foi avaliado pelo pico de 960 cm-1 da apatita. De acordo com os resultados obtidos, a aplicação de múltiplas camadas apresentou uma tendência de homogeneização dos componentes poliméricos, dependente da composição química da resina adesiva.
The present study analyzed the effect of multiple consecutive adhesive coatings on the pattern of resin diffusion and distribution of monomer components through demineralised dentin after application of two total-etch adhesives. Resin bonded dentin specimens were prepared using two total-etch adhesives (Prime&Bond NT2.1 and Adper Single Bond). The specimens were sectioned parallel to dentinal tubules and the surfaces were polished using 600, 1200, 1800, 2000 and 4000 silicon-carbide papers. Raman spectra were recorded along a line perpendicular to the dentin-resin interface in steps of 1 or 2 m. The measurements of resin diffusion and distribution of monomer components were made on a relative basis by comparing the bands 1113, 1609 and 1454 cm-1. The gradient of dentin demineralization, designed to 960 cm-1, was used to determine the extent of hybridization. From the results of the present study the application of multiple coatings of adhesive showed a trend to produce a homogeneous hybrid layer.
APA, Harvard, Vancouver, ISO, and other styles

Books on the topic "Adesivi dentali"

1

Rossella, Bedini, ed. Valutazione meccanica, ultrastrutturale e clinica di ricostruzioni endodontiche eseguite con vari tipi di adesivi smalto-dentinali e perni in fibra di carbonio. Roma: Istituto superiore di sanità, 1998.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography