Contents
Academic literature on the topic 'Імпульсний трансформатор'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Імпульсний трансформатор.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Імпульсний трансформатор"
Svyatnenko, R., A. Marynin, A. Makogon, and O. Fursik. "Вплив імпульсних електричних полів на мікробіологічні показники та вміст вітаміну С в незбираному молоці." Scientific Messenger of LNU of Veterinary Medicine and Biotechnologies 19, no. 80 (October 6, 2017): 29–32. http://dx.doi.org/10.15421/nvlvet8006.
Full textDissertations / Theses on the topic "Імпульсний трансформатор"
Іванов, Володимир Михайлович, and Валентина Євгенівна Марценюк. "Особливості джерела живлення електротехнологічної установки." Thesis, НТУ "ХПІ", 2016. http://repository.kpi.kharkov.ua/handle/KhPI-Press/24888.
Full textІванов, Володимир Михайлович. "Удосконалення високовольтних імпульсних трансформаторів з напівпровідниковими комутаторами для електротехнологічних установок." Thesis, Стиль Издат, 2015. http://repository.kpi.kharkov.ua/handle/KhPI-Press/18951.
Full textDissertation for competition a technical science candidate degree. Speciality 05.09.13. "High electric and magnetic field engineering". National Technical University "Kharkov Polytechnical Institute", Kharkov, 2015. In this work the scientific and practical problem of improvement of high-voltage pulsed transformers with using semiconductor switches for electrophysical plants has been solved which enabled to modernize existing and to create new electrotechnological plants that generate strong pulsed electric and magnetic fields. It was found that improvement of high-voltage transformers, which consist in that the parts of the secondary and primary windings are separated and placed not at one common core but at four crosswise situated parts of split core of magnetic circuit, enabled to reduce a resulting leakage inductance of the transformers. Using them in two-stage circuit of voltage pulse generator enabled to create a compact pulsed voltage source with pulse rise time 250 ns at a capacitive load about 1 nF and voltage of 1 MV. Accident-free rational operation modes of pulsed transformers with semiconductor switches in generators for creating PCD with high pulse repetition frequency have been investigated. For the first time in the factory conditions a plant on the basis of pulsed transformers with semiconductor switches in the circuit of the generator of voltage pulses for steam reforming of methane as part of coke-oven gas into synthesis gas with help of high-voltage pulsed volumetric discharges: corona and barrier discharge with nickel catalyst in the reactor, has been successfully test-operated.
Росінська, Г. П. "Стабілізатор змінної напруги." Thesis, Київський національний університет технологій та дизайну, 2017. https://er.knutd.edu.ua/handle/123456789/6692.
Full textРослий, Кирило Євгенович. "Дослідження та розробка перетворювача постійної напруги для локальної енергосистеми потужністю 1 кВт." Магістерська робота, 2020. https://dspace.znu.edu.ua/jspui/handle/12345/4971.
Full textUA : Розглянуто методику розрахунку та аналізу математичних моделей імпульсних перетворювачів постійної напруги. Синтезована візуально блочна модель імпульсного перетворювача постійної напруги звотноходового типу. Проведено аналіз адекватності, працездатності і точності моделі.
EN : The method of calculation and analysis of mathematical models of pulse converters of direct voltage is considered. Visually block model of pulse converter of direct voltage of return type is synthesized. The analysis of adequacy, efficiency and accuracy of the model is carried out.